DOP-B07 High ColorWide Screen User-Friendly HMI ProductsB07S411/B07S411K Instrunction Sheet
(1) Preface Thank you for purchasing DELTAs DOP-B series. This instruction sheet will be helpful in the installation, wiring and inspection of Delta HMI. Before using the product, please read this instruction sheet to ensure correct use. You should thoroughly understand all safety precautions before proceeding with the installation, wiring and operation. Place this instruction sheet in a safe location for future reference. Please observe the following precautions: Install the product in a clean and dry location free from corrosive and inflammable gases or liquids. Ensure that all wiring instructions and recommendations are followed. Ensure that HMI is correctly connected to a ground. The grounding method must comply with the
electrical standard of the country (Please refer to NFPA 70: National Electrical Code, 2005 Ed.). Do not disassemble HMI, modify or remove wiring when power is applied to HMI. Do not touch the power supply during operation. Otherwise, it may cause electric shock.
If you have any questions during operation, please contact our local distributors or Delta sales representatives. The content of this instruction sheet may be revised without prior notice. Please consult our distributors or download the most updated version at http://www.delta.com.tw/industrialautomation.
(2) Pin Definition of Serial Communication DOP-B07S411 / DOP-B07S411K COM1 Port
MODE1 COM Port PIN
RS-232 1 2 RXD 3 TXD 4 5 GND 6 7 RTS 8 CTS
9
DOP-B07S411 / DOP-B07S411K COM2 Port MODE1 MODE2 MODE3
COM2 COM3 COM2 COM3 COM2 COM3 COM Port PIN
RS-232 RS-485 RS-485 RS-485 RS-232 RS-422 1 D+ TXD+ 2 RXD RXD 3 TXD TXD 4 D+ D+ RXD+ 5 GND GND GND 6 D- TXD- 7 8
9 D- D- RXD-
Note1: Blank = No Connection.
(3) Parts Names DOP-B07S411 (Front View)
A Touch Screen / Display B Power LED Indicator
DOP-B07S411K (Front View)
A
User-defined Function Keys / System Keys
User-defined Function Keys: F1, F2, F3, F4
System Keys: , , , SYS
B : Power LED Indicator
Lights in green when HMI works normally.
C
: Operation LED Indicator (Blue) (Note1)
The operation LED indicator blinks in blue when either the communication is carried
out or the data is accessing (please refer to the Note1 below for explanation).
: Alarm LED Indicator (Red)
The alarm LED indicator blinks in red when one of the alarms is on.
D Touch Screen / Display
NOTE
1. The definition of the operation LED indicator (Blue) can be determined by the users freely.
DOP-B07S411 / DOP-B07S411K (Rear View)
A Power Input Terminal B COM1
C COM2 D USB Slave
E USB Host F Battery Case / System Key
DOP-B07S411 / DOP-B07S411K
215(8.46")
161(
6.34
")
+1.0196.9 0
+1.0
142.
9 0
142.
3(5.
6")
T51.2(2.02")
Note:T=1.6mm(0.063")~6mm(0.24")
+0.04"(7.75" )-0
+0.0
4"(5
.63"
)-0
D
A
(5) Specifications CBMODEL DOP-B07S411 DOP-B07S411K
Display Type 7" TFT LCD (65535 colors)
Resolution 800 x 480 pixels
Backlight LED Back Light (less than 20,000 hours half-life at 25oC) (Note 1)
LCD
MO
DU
LE
Display Size 154.08 x 85.92mm 154.1 x 87.6mm
Operation System Delta Real Time OS
MCU 32-bit RISC Micro-controller
NOR Flash ROM Flash ROM 128 MB (OS System: 30MB / Backup: 16MB / User Application: 82MB)
SDRAM 64Mbytes
Backup Memory 32Kbytes
Buzzer Multi-Tone Frequency2K ~ 4K Hz85dB
USB 1 USB Slave Ver 2.0 1 USB Host Ver 1.1
COM1 RS-232(supports hardware flow control)
COM2 RS-232 / RS-485 Serial COM PortCOM3 RS-422 / RS-485
Function Key N/A User defined key x 4 + System key x 4
Perpetual Calendar (RTC) Built-in
Cooling Method Natural air circulation
Safety Approval CE
Waterproof Degree IP65
Operation Voltage (Note2) DC +24V-10% ~ +15%(please use isolated power supply)
Voltage Endurance AC500V for 1 minute (between charging (DC24V terminal) and FG terminals)
Power Consumption (Note 2) 4.0W
Backup Battery 3V lithium battery CR2032 1
Backup Battery Life It depends on the temperature used and the conditions of usage, about 3 years or more at 25oC.
Operation Temperature 0oC ~ 50
oC
Storage Temperature -20oC ~ +60
oC
Ambient Humidity 10% ~ 90% RH [0 ~ 40oC], 10% ~ 55% RH [41 ~ 50
oC]
Pollution Degree 2
Vibration Resistance
IEC 61131-2 Compliant 5Hzf9Hz = Continuous: 1.75mm / Occasional: 3.5mm
9Hzf150Hz = Continuous: 0.5g / Occasional: 1.0g X, Y, Z directions for 10 times
Dimensions (W) x (H) x (D) mm 215 x 161 x 50
Panel Cutout (W) x (H) mm 196.9 x 142.9
Weight Approx. 820g Approx. 840g
PIN1
(4) Dimensions
NOTE
1) The half-life of backlight is defined as original luminance being reduced by 50% when the maximum driving current is supplied to HMI. The life of LED backlight shown here is an estimated value under 25 oC normal temperature and humidity conditions.
2) The value of the power consumption indicates the electrical power consumed by HMI only without connecting to any peripheral devices. In order to ensure the normal operation, it is recommended to use a power supply which the capacity is 1.5 ~2 times the value of the power consumption.
3) The content of this instruction sheet may be revised without prior notice. Please consult our distributors or download the most updated version at http://www.delta.com.tw/industrialautomation/.
A B
A
BC
F
PIN1
ED
http://www.delta.com.tw/industrialautomationhttp://www.delta.com.tw/industrialautomation/
DOP-B07 Yksek RenkGeni Ekran Kullanm Kolay HMI rnleriB07S411/B07S411K Bilgi Dkman
(1) nsz DELTAnn DOP-B serisi operatr panellerini setiiniz iin teekkrler. Bu bilgi dkman Delta HMI kurulum, balant, bakm ve kontrolnde kullancya yardmc olacaktr. Doru kullanm iin rn kullanmadan nce bu dkman mutlaka okuyunuz. Kurulum, balant ve alma yapmadan nce gvenlik uyarlarn tamamen anladnzdan emin olunuz. Bu dkman daha sonra da kullanmak iin iyi muhafaza ediniz. Ltfen aadaki gvenlik uyarlarna dikkat ediniz: rnn kurulumunu yanc gaz ve svlardan uzak kuru ve temiz ortamlara yapnz. Balantlar yaparken tm balant kurallarnn salandndan emin olunuz. HMInn toprak balantsnn doru yapldndan emin olunuz. Topraklama metodunun rnn
kurulduu lke standartlarna uygun olduuna emin olunuz (NFPA 70: National Electrical Code, 2005 Ed.).
HMI enerjili iken kablo balants yapmaynz ya da skmeyiniz. alma srasnda enerji besleme terminallerine dokunmaynz. Aksi halde elektrik oku olabilir.
rnn kullanm ile ilgili sorularnz iin, ltfen teknik servisimizle balantya geiniz. Herhangi bir ihbara gerek kalmakszn bu bilgi dkmannn ierii deitirilebilir. Gncellenmi versiyonu elde etmek iin teknik servise danabilir veya internet adresinden indirebilirsiniz. http://www.delta.com.tw/industrialautomation
(2) Seri Haberleme Pin Aklamalar DOP-B07S411 / DOP-B07S411K COM1 Port
MOD 1 COM Port PIN RS-232
1 2 RXD 3 TXD 4 5 GND 6 7 RTS 8 CTS
9
DOP-B07S411 / DOP-B07S411K COM2 Port MODE1 MODE2 MODE3
COM2 COM3 COM2 COM3 COM2 COM3 COM Port PIN
RS-232 RS-485 RS-485 RS-485 RS-232 RS-422 1 D+ TXD+ 2 RXD RXD 3 TXD TXD 4 D+ D+ RXD+ 5 GND GND GND 6 D- TXD- 7 8
9 D- D- RXD-
Not 1: Bo = Balant Yaplmaz.
(3) Para simleri
DOP-B07S411 (n Grnm)
A Dokunmatik Ekran / Display B Power LED Indikatr
DOP-B07S411K (n Grnm)
A
Kullanc-tanml Fonksiyon Tular / Sistem Tular
Kullanc-tanml Fonksiyon Tular: F1, F2, F3, F4
Sistem Tular: , , , SYS
B : Power LED Indikator
HMI normal altnda yeil yanar.
C
: alma LED Indikator (Mavi) (Not 1)
Haberleme saland zaman veya data iletiimi srasnda alma LEDi mavi flash yapar .
(Ltfen aadaki Not 1i inceleyiniz).
: Sa kenar: Alarm LED Indikator (Krmz)
Herhangi bir alarm aktif olduunda Alarm LED indikator krmz flash yapar.
D Touch Screen / Display
NOTE
1. alma LED indikatr (mavi) tanmlamas kullanc tarafndan belirlenebilir.
DOP-B07S411 / DOP-B07S411K (Arka Grnm)
A Power Giri Terminali B COM1
C COM2 D USB Slave
E USB Host F Pil Kapa / Sistem Tuu
DOP-B07S411 / DOP-B07S411K
215(8.46")
161(
6.34
")
+1.0196.9 0
+1.0
142.
9 0
142.
3(5.
6")
T51.2(2.02")
Note:T=1.6mm(0.063")~6mm(0.24")
+0.04"(7.75" )-0
+0.0
4"(5
.63"
)-0
D
(4) ller
(5) zellikler MODEL DOP-B07S411 DOP-B07S411K
Display Tipi 7" TFT LCD (65535 renk)
znrlk 800 x 480 piksel
Aydnlatma LED Aydnlatma (25oC yarm mrde 20,000 saatden az) (Not 1)
LCD
MO
D
L
Display l 154.08 x 85.92mm 154.1 x 87.6mm
letim Sistemi Delta Real Time OS
MCU 32-bit RISC Micro-ilemci
NOR Flash ROM Flash ROM 128 MB (OS Sistem: 30MB / Backup: 16MB / Kullanc Uygulama: 82MB)
SDRAM 64Mbyte
Backup Memory 32Kbyte
Buzzer Multi-Ton Frekans2K ~ 4K Hz85dB
USB 1 USB Slave Ver 2.0 1 USB Host Ver 1.1
COM1 RS-232(donanm flow (ak) kontrol destekler)
COM2 RS-232/RS-485 Seri COM Port
COM3 RS-422/RS-485
Fonksiyon Tuu N/A 4 adet kullanc tanml tu + 4 adet sistem tuu
Gerek Zaman Saati(RTC) Dahili
Soutma Metodu Doal hava sirkulasyonu
Gvenlik Onay CE
Su Geirmezlik Derecesi IP65
alma Voltaj (Not2) DC +24V-10% ~ +15%(ltfen izoleli g kayna kullannz)
Dayanma Voltaj 1 dakika iin AC500V (DC24V besleme terminalleri ve FG terminalleri arasnda)
G Tketimi (Not 2) 4.0W
Backup Pili 3V lityum pil CR2032 1
Backup Pil mr Kullanm koullar ve ortam scaklna bal olarak 25oCde yaklak 3 yl veya
zeri.
alma Scakl 0oC ~ 50
oC
Saklama Scakl -20oC ~ +60
oC
Rutubet Oran 10% ~ 90% RH [0 ~ 40oC], 10% ~ 55% RH [41 ~ 50
oC]
Kirlenme Derecesi 2
Titreim Direnci
IEC 61131-2 Uyumlu 5Hzf9Hz = Srekli: 1.75mm / Geici: 3.5mm
9Hzf150Hz = Srekli: 0.5g / Geici: 1.0g X, Y, Z ynnde 10 defa
ller (W) x (H) x (D) mm 215 x 161 x 50
Panel Kesim ls (W) x (H) mm 196.9 x 142.9
Arlk Yaklak 820g Yaklak 840g
NOTE 1) Arka k yarm-mr, HMI maksimum akmla beslendiinde orijinal aydnlatmann %50 drld anlamna gelir.
Yukarda gsterilen arka k LED aydnlatma mr 25 oC de derecede normal scaklk ve rutubet ortamnda tahmin edilen deerlerdir.
2) G tketimi HMI nitesinin hi bir cihaza bal olmadan bo olarak tkettii gc gsterir. Normal almada HMInn boken tkettii gcn 1.5 veya 2 kat g verebilen besleme kayna kullanlmas tavsiye edilir.
3) Herhangi bir ihbar olmadan bu dkmann ierii deitirilebilir. En son gncellenmi halini firmamzdan talep edebilir yada aadaki link adresinden indirebilirsiniz
http://www.delta.com.tw/industrialautomation/
A B
A
BC
E
F
PIN1
D PIN1
A
B C
http://www.delta.com.tw/industrialautomationhttp://www.delta.com.tw/industrialautomation/
DOP-B07 B07S411 / B07S411K
(1) DOP-B
NFPA 70:
National Electrical Code, 2005 Ed.
http://www.delta.com.tw/industrialautomation/
(2) DOP-B07S411 / DOP-B07S411K COM1
MODE1 COM Port RS-232
1 2 RXD 3 TXD 4 5 GND 6 7 RTS 8 CTS
9
DOP-B07S411 / DOP-B07S411K COM2
MODE1 MODE2 MODE3
COM2 COM3 COM2 COM3 COM2 COM3 COM Port
RS-232 RS-485 RS-485 RS-485 RS-232 RS-422 1 D+ TXD+ 2 RXD RXD 3 TXD TXD 4 D+ D+ RXD+ 5 GND GND GND 6 D- TXD- 7 8
9 D- D- RXD- 1
(3)
DOP-B07S411()
A B
DOP-B07S411K() (5)
A F1, F2, F3, F4
, , , SYS
B
C
D /
DOP-B07S411 / DOP-B07S411K()
A B COM1
C COM2 D USB Slave
E USB Host F
(4)
DOP-B07S411 / DOP-B07S411K
DOP-B07S411 DOP-B07S411K
7" TFT LCD65535
800 x 480 pixels
LED Back Light 25oC >2 (Note 1)
154.08 x 85.92mm 154.1 x 87.6mm
Delta Real Time OS
32-bit RISC Micro-controller
ROM Flash ROM 128 MB (OS System: 30MB / Backup: 16MB / User Application: 82MB) 64Mbytes
32Kbytes
Multi-Tone Frequency2K ~ 4K Hz85dB
USB 1 USB Slave Ver 2.0 1 USB Host Ver 1.1
COM1 RS-232()
COM2 RS-232 / RS-485
COM3 RS-422 / RS-485
N/A x4
x4
CE
IP65
(Note2) DC +24V-10% ~ +15%
DC24V FG AC500V, 1
(Note 2) 4.0W
3V CR2032 1
25oC
0oC ~ 50
oC
-20oC ~ +60
oC
10% ~ 90% RH0 ~ 40oC10% ~ 55% RH41 ~ 50
oC 2
IEC61131-2
5Hz-9Hz 3.5mm, 9Hz-150Hz 1G
5Hz-9Hz 1.75mm, 9Hz-150Hz 0.5G
X, Y, Z 10
WxHxDmm
215 x 161 x 50
WxHmm 196.9 x 142.9
820g 840g
D
A
B C
F
PIN1
215(8.46")
161(
6.34
")
+1.0196.9 0
+1.0
142.
9 0
142.
3(5.
6")
T51.2(2.02")
Note:T=1.6mm(0.063")~6mm(0.24")
+0.04"(7.75" )-0+0
.04"
(5.6
3"
)
-0
NOTE
1) 25
oC
2) 1.5~2
3) http://www.delta.com.tw/industrialautomation/
A B
A
BC
ED
PIN1
http://www.delta.com.tw/industrialautomation/
DOP-B07 B07S411 / B07S411K
(1) DOP-B
NFPA 70:
National Electrical Code, 2005 Ed.
http://www.delta.com.tw/industrialautomation/
(2)
DOP-B07S411 / DOP-B07S411K COM1
MODE1 COM Port RS-232
1 2 RXD 3 TXD 4 5 GND 6 7 RTS 8 CTS
9
DOP-B07S411 / DOP-B07S411K COM2
MODE1 MODE2 MODE3
COM2 COM3 COM2 COM3 COM2 COM3 COM Port
RS-232 RS-485 RS-485 RS-485 RS-232 RS-422 1 D+ TXD+ 2 RXD RXD 3 TXD TXD 4 D+ D+ RXD+ 5 GND GND GND 6 D- TXD- 7 8
9 D- D- RXD-
1
(3)
DOP-B07S411()
A B
DOP-B07S411K (5)
A F1, F2, F3, F4
, , , SYS
B
C
D /
DOP-B07S411 / DOP-B07S411K ()
A B COM1
C COM2 D USB Slave
E USB Host F
(4)
DOP-B07S411 / DOP-B07S411K
DOP-B07S411 DOP-B07S411K
7" TFT LCD65535
800 x 480 pixels
LED Back Light 25oC>2 (Note 1)
154.08 x 85.92mm 154.1 x 87.6mm
Delta Real Time OS
32-bit RISC Micro-controller
ROM Flash ROM 128 MB (OS System: 30MB / Backup: 16MB / User Application: 82MB) 64Mbytes
32Kbytes
Multi-Tone Frequency2K ~ 4K Hz85dB
USB 1 USB Slave Ver 2.0 1 USB Host Ver 1.1
COM1 RS-232()
COM2 RS-232 / RS-485
COM3 RS-422 / RS-485
N/A x4 x4
CE
IP65
(Note2) DC +24V-10% ~ +15%
DC24V FGAC500V, 1
(Note 2) 4.0W
3V CR2032 1
25oC
0oC ~ 50
oC
-20oC ~ +60
oC
10% ~ 90% RH0 ~ 40oC10% ~ 55% RH41 ~ 50
oC 2
IEC61131-2
5Hz-9Hz 3.5mm, 9Hz-150Hz 1G
5Hz-9Hz 1.75mm, 9Hz-150Hz 0.5G
X, Y, Z 10
WxHxDmm
215 x 161 x 50
WxHmm 196.9 x 142.9
820g 840g
D
215(8.46")
161(
6.34
")
+1.0196.9 0
+1.0
142.
9 0
142.
3(5.
6")
T51.2(2.02")
Note:T=1.6mm(0.063")~6mm(0.24")
+0.04"(7.75" )-0
+0.0
4"(5
.63"
)-0
NOTE
1)
25 oC
2)
1.5~2
3)
http://www.delta.com.tw/industrialautomation/
A B
A
BC
E
F PIN1
D
PIN1
A
B C
http://www.delta.com.tw/industrialautomation/
5012614601-ENG.pdf5012614601-TR5012614601-TC5012614601-SC