66
Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-1 TABLE OF CONTENTS General Information ................................................... 2-2 Elevations/Sizes: 1/4” & 1/8” Scale Single Units .................................................... 2-5 Twin Units ..................................................... 2-14 Triple Units .................................................... 2-21 4-Wide Units ................................................... 2-29 5-Wide Units ................................................... 2-31 Double-Hung Picture ........................................... 2-34 Double-Hung Transom .......................................... 2-44 Glazing Options ........................................................ 2-50 Jamb Extender Options ................................................. 2-51 Standard Mullion Options ............................................... 2-52 Lite Cut Information .................................................... 2-54 Unit Sizing Information ................................................. 2-56 Clear Opening Layout ................................................... 2-57 Section Details ........................................................ 2-58 W-2500 Double-Hung Windows

Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-1

TABLE OF CONTENTS

General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2

Elevations/Sizes: 1/4” & 1/8” Scale

Single Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5

Twin Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14

Triple Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21

4-Wide Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-29

5-Wide Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31

Double-Hung Picture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-34

Double-Hung Transom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-44

Glazing Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-50

Jamb Extender Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-51

Standard Mullion Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-52

Lite Cut Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-54

Unit Sizing Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-56

Clear Opening Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-57

Section Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-58

W-2500

Double-Hung Windows

Page 2: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-2

Clad double hung windows feature fully operating upper and lower sash.Counterbalancing is achieved with helical spring extension systems hidden inweatherable PVC jambliners. Operating units are supplied with cam-type sashlocks installed. There are several hardware finish options. Refer to theSpecifications for available finish options.

MULTIPLE ASSEMBLIESClad double hung windows may be mulled beside other clad double hungs or clad picturewindows, or below clad transom windows, to fulfill a wide variety of needs. Factory assembledmulls are limited in height (100”), width (114”), and a total area (75 square feet).

GENERAL INFORMATION

Double-Hung Windows

W-2500

Page 3: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-3

ELEVATION DRAWINGS UTILIZE A LIMITED NUMBER OF PROJECTED LINES TO PRODUCE A RUDIMENTARY DRAWING INTENDEDTO BE USED IN A SMALL GRAPHICAL SCALE. ELEVATIONS ARE VIEWED PERPENDICULAR FROM THE EXTERIOR OF THESTRUCTURE. IF MORE DIMENSIONS ARE NEEDED, USE THE SECTION DRAWINGS FOR MORE COMPLETE DEPICTIONS.

’25CDH’ INDICATESW2500 CLAD DOUBLE HUNG

THE FIRST TWO NUMBERSINDICATE THE UNIT WIDTH

THE LAST TWO NUMBERS INDICATETHE UNITS HEIGHT

BOOK CODE

OUTSIDE OF FRAME.

ROUGH OPENINGDIMENSIONS ARE

IN BOLD TEXT.

Masonry Openings for Brickmould, Flat & Adams Casing.Vertical measurements include sillnose.(Subtract 1/2” from Masonry Opening for Unit Size)

Daylight OpeningFrame Size

M.O. Brickmould

Rough OpeningM.O. Adams/Flat Casing

GENERAL DOUBLE HUNG NOTES

39 1/16” [ 992 ]40 9/16” [ 1030 ]36 3/4” [ 933 ]36” [ 914 ]14 11/16” [ 373 ]

24 7/8” [ 632 ]27 7/8” [ 708 ]22 1/8” [ 562 ]21 3/8”(543)16 1/16”(408)

1. ALL UNITS SHOWN ARE AVAILABLE AS OPERATORS ONLY.

2. UNIT ELEVATIONS ARE SHOWN WITHOUT EXTERIOR TRIM.

3. ALL OPERATING SASH ARE INSTALLED WITH VINYL JAMB LINERS ANDOPERATED WITH AN INTERNAL HELICAL SPRING SYSTEM.

4. DIMENSIONAL VALUES IN BRACKETS ARE MILLIMETER CONVERSIONS.

25CDH2136

UNIT WIDTH

UNIT HEIGHT

LOWER SASHVERTICAL GLASS

25CDH2148C24

COTTAGE & REVERSE COTTAGEBOOK CODES

C = COTTAGER = REVERSE COTTAGE

ELEVATION SYMBOL LEGEND:

BASIC UNIT CLEAR OPENING EXCEEDS 20” IN WIDTH, 24” INHEIGHT & A MINIMUM OF 5.7 SQ. FT.

NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITHSTANDARD GLAZING.

##

E

SEE SYMBOL LEGEND BELOW

DAYLIGHT OPENING

##

ELEVATION NOTES

Double-Hung Windows

W-2500

Page 4: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-4

SASH TILTING FOR WASHINGThe Custom Double Hung window will allow the sash to be tilted or removed for easycleaning.

DOUBLE HUNG OPERATION:When the sash are locked at thecheck rails the sash are closed andsealed in the sash opening of theframe.

When the sash are unlocked thelower sash travels vertically to anyposition desired. The upper sash canalso be positioned as desired.

OPERATION & SASH TILTING

Double-Hung Windows

W-2500

Page 5: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-5

SINGLE UNITS

E1 UNITS WITH AN E1 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH A DP35 SILL STOP, BUT NOT WITH A DP 50 SILL STOP.E2 UNITS WITH AN E2 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH EITHER A DP35 OR A DP 50 SILL STOP.E3 UNITS WITH AN E3 EGRESS DESIGNATION MEET 5.7 SQ FT EGRESS WITH A DP35 SILL STOP, BUT NOT WITH A DP 50 SILL STOP.E4 UNITS WITH AN E4 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH EITHER A DP35 OR A DP 50 SILL STOP.

ELEVATION SYMBOL LEGEND:

##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.

VALUES IN () ARE IN MILLIMETER CONVERSIONS.

##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

16 1/16”(408)21 3/8”(543)22 1/8”(562)24 1/8”(613)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

36”(

914)

363/

4”(9

33)

383/

4”(9

84)

25CDH2136 25CDH2536 25CDH2936 25CDH3336 25CDH3736 25CDH4136

25CDH2140 25CDH2540 25CDH2940 25CDH3340 25CDH3740 25CDH4140

25CDH2148 25CDH2548 25CDH2948 25CDH3348 25CDH3748 25CDH4148

25CDH2152 25CDH2552 25CDH2952 25CDH3352 25CDH3752 25CDH4152

25CDH2156 25CDH2556 25CDH2956 25CDH3356 25CDH3756 25CDH4156

25CDH2160 25CDH2560 25CDH2960 25CDH3360 25CDH3760 25CDH4160

20 1/16”(510)25 3/8”(645)26 1/8”(664)28 1/8”(714)

24 1/16”(611)29 3/8”(746)30 1/8”(765)32 1/8”(816)

28 1/16”(716)33 3/8”(848)34 1/8”(867)36 1/8”(918)

32 1/16”(814)37 3/8”(949)38 1/8”(968)

40 1/8”(1019)

36 1/16”(916)41 3/8”(1051)42 1/8”(1070)44 1/8”(1121)

40”(

1016

)40

3/4”

(103

5)42

3/4”

(108

6)

48”(

1219

)48

3/4”

(123

8)50

3/4”

(128

9)

52”(

1321

)52

3/4”

(134

0)54

3/4”

(139

1)

56”(

1441

)56

3/4”

(144

1)58

3/4”

(149

2)

60”(

1543

)60

3/4”

(154

3)62

3/4”

(159

4)

1411

/16”

(373

)[2] 35*

50**

E2 E4 E3

E1 E1 E3

35*50**

35*50**

35*50**

35*50**

35*

35*50**

35*50**

35*50**

35*50**

35*50**

35*

35*50**

35*50**

35*50**

35*50**

35*50**

35*

35*50**

35*50**

35*50**

35*50**

35*50**

35*

35*50**

35*50**

35*50**

35*50**

35*50**

35*

35*50**

35*50**

35*50**

35*50**

35*50**

35*

1611

/16”

(424

)[2]

2011

/16”

(525

)[2]

2211

/16”

(576

)[2]

2411

/16”

(627

)[2]

2611

/16”

(678

)[2]

Double-Hung Windows

W-2500

SCALE: 1/4” = 1’

Page 6: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-6

SINGLE UNITS

25CDH2164 25CDH2564 25CDH2964 25CDH3364 25CDH3764 25CDH4164

25CDH2168 25CDH2568 25CDH2968 25CDH3368 25CDH3768

25CDH2172 25CDH2572 25CDH2972 25CDH3372 25CDH3772

25CDH2176 25CDH2576 25CDH2976 25CDH3376 25CDH3776

64”(

1626

)64

3/4”

(164

5)66

3/4”

(169

5)

68”(

1727

)68

3/4”

(174

6)70

3/4”

(179

7)

72”(

1829

)72

3/4”

(184

8)74

3/4”

(189

9)

76”(

1930

)76

3/4”

(194

9)78

3/4”

(200

0)

E2

16 1/16”(408)21 3/8”(543)22 1/8”(562)24 1/8”(613)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

20 1/16”(510)25 3/8”(645)26 1/8”(664)28 1/8”(714)

24 1/16”(611)29 3/8”(746)30 1/8”(765)32 1/8”(816)

28 1/16”(716)33 3/8”(848)34 1/8”(867)36 1/8”(918)

32 1/16”(814)37 3/8”(949)38 1/8”(968)

40 1/8”(1019)

36 1/16”(916)41 3/8”(1051)42 1/8”(1070)44 1/8”(1121)

E4 E4 E4

E4

E2

E2

E4 E4

E4 E4

E4 E4 E3

35*50**

35*50**

35*50**

35*50**

35*50**

35*

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35**50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

3411

/16”

(881

)[2]

3211

/16”

(830

)[2]

3011

/16”

(779

)[2]

2711

/16”

(703

)[2]

E1 UNITS WITH AN E1 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH A DP35 SILL STOP, BUT NOT WITH A DP 50 SILL STOP.E2 UNITS WITH AN E2 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH EITHER A DP35 OR A DP 50 SILL STOP.E3 UNITS WITH AN E3 EGRESS DESIGNATION MEET 5.7 SQ FT EGRESS WITH A DP35 SILL STOP, BUT NOT WITH A DP 50 SILL STOP.E4 UNITS WITH AN E4 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH EITHER A DP35 OR A DP 50 SILL STOP.

ELEVATION SYMBOL LEGEND:

##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.

VALUES IN () ARE IN MILLIMETER CONVERSIONS.

##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/4” = 1’

Page 7: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-7

SINGLE UNITS - NOMINAL

25CDH2036N 25CDH2436N 25CDH2836N 25CDH3236N 25CDH3636N

25CDH2042N 25CDH2442N 25CDH2842N 25CDH3242N 25CDH3642N

25CDH2048N 25CDH2448N 25CDH2848N 25CDH3248N 25CDH3648N

25CDH2054N 25CDH2454N 25CDH2854N 25CDH3254N 25CDH3654N

25CDH2060N 25CDH2460N 25CDH2860N 25CDH3260N 25CDH3660N

13 15/16”(354)19 1/4”(489)

20”(508)22”(559)

351/

4”(8

95)

36”(

914)

38”(

965)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

411/

4”(1

048)

42”(

1067

)44

”(11

18)

471/

4”(1

200)

48”(

1219

)50

”(12

70)

531/

4”(1

353)

54”(

1372

)56

”(14

22)

591/

4”(1

505)

60”(

1524

)62

”(15

75)

145/

16”(

364)

[2]

17 15/16”(455)23 1/4”(591)

24”(610)26”(660)

21 15/16”(557)27 1/4”(692)

28”(711)30”(762)

25 15/16”(659)31 1/4”(794)

32”(813)34”(864)

29 15/16”(760)35 1/4”(895)

36”(914)38”(965)

35*50**

E1 E3

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

175/

16”(

440)

[2]

205/

16”(

515)

[2]

235/

16”(

592)

[2]

265/

16”(

668)

[2]

E1 UNITS WITH AN E1 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH A DP35 SILL STOP, BUT NOT WITH A DP 50 SILL STOP.E2 UNITS WITH AN E2 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH EITHER A DP35 OR A DP 50 SILL STOP.E3 UNITS WITH AN E3 EGRESS DESIGNATION MEET 5.7 SQ FT EGRESS WITH A DP35 SILL STOP, BUT NOT WITH A DP 50 SILL STOP.E4 UNITS WITH AN E4 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH EITHER A DP35 OR A DP 50 SILL STOP.

ELEVATION SYMBOL LEGEND:

##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.

VALUES IN () ARE IN MILLIMETER CONVERSIONS.

##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

N INDICATES NOMINALSIZING.

Double-Hung Windows

W-2500

SCALE: 1/4” = 1’

Page 8: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-8

SINGLE UNITS - NOMINAL

25CDH2066N 25CDH2466N 25CDH2866N 25CDH3266N 25CDH3666N

25CDH2072N 25CDH2472N 25CDH2872N 25CDH3272N 25CDH3672N

651/

4”(1

657)

66”(

1676

)68

”(17

27)

711/

4”(1

810)

72”(

1829

)74

”(18

80)

13 15/16”(354)19 1/4”(489)

20”(508)22”(559)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

17 15/16”(455)23 1/4”(591)

24”(610)26”(660)

21 15/16”(557)27 1/4”(692)

28”(711)30”(762)

25 15/16”(659)31 1/4”(794)

32”(813)34”(864)

29 15/16”(760)35 1/4”(895)

36”(914)38”(965)

E2 E4 E4

E2 E4

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

295/

16”(

745)

[2]

325/

16”(

821)

[2]

E1 UNITS WITH AN E1 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH A DP35 SILL STOP, BUT NOT WITH A DP 50 SILL STOP.E2 UNITS WITH AN E2 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH EITHER A DP35 OR A DP 50 SILL STOP.E3 UNITS WITH AN E3 EGRESS DESIGNATION MEET 5.7 SQ FT EGRESS WITH A DP35 SILL STOP, BUT NOT WITH A DP 50 SILL STOP.E4 UNITS WITH AN E4 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH EITHER A DP35 OR A DP 50 SILL STOP.

ELEVATION SYMBOL LEGEND:

##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.

VALUES IN () ARE IN MILLIMETER CONVERSIONS.

##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

N INDICATES NOMINALSIZING.

Double-Hung Windows

W-2500

SCALE: 1/4” = 1’

Page 9: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-9

SINGLE UNITSWITH 15” TRANSOM

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

20 1/16”(510)25 3/8”(645)26 1/8”(664)28 1/8”(714)

24 1/16”(611) 28 1/16”(716) 32 1/16”(814)29 3/8”(746)30 1/8”(765)32 1/8”(816)

33 3/8”(848)34 1/8”(867)36 1/8”(918)

37 3/8”(949)38 1/8”(968)

40 1/8”(1019)

EEE

EEE

EE

EE

25CDH2536-1T15

25CDH2540-1T15

25CDH2548-1T15

25CDH2552-1T15

25CDH2556-1T15

25CDH2560-1T15

25CDH2564-1T15

25CDH2568-1T15

25CDH2936-1T15

25CDH2940-1T15

25CDH2948-1T15

25CDH2952-1T15

25CDH2956-1T15

25CDH2960-1T15

25CDH2964-1T15

25CDH2968-1T15

25CDH3336-1T15

25CDH3340-1T15

25CDH3348-1T15

25CDH3352-1T15

25CDH3356-1T15

25CDH3360-1T15

25CDH3364-1T15

25CDH3368-1T15

25CDH3736-1T15

25CDH3740-1T15

25CDH3748-1T15

25CDH3752-1T15

25CDH3756-1T15

25CDH3760-1T15

25CDH3764-1T15

25CDH3768-1T15

1411

/16”

(373

)[2]

51”(

1295

)51

3/4”

(131

4)53

3/4”

(136

5)

101/

4”(2

60)

55”(

1397

)55

3/4”

(141

6)57

3/4”

(146

7)

101/

4”(2

60)

63”(

1600

)63

3/4”

(161

9)65

3/4”

(167

0)

101/

4”(2

60)

67”(

1702

)67

3/4”

(172

1)69

3/4”

(177

2)

101/

4”(2

60)

71”(

1803

)71

3/4”

(182

2)73

3/4”

(187

3)

101/

4”(2

60)

75”(

1905

)75

3/4”

(192

4)77

3/4”

(197

5)

101/

4”(2

60)

79”(

2007

)79

3/4”

(202

6)81

3/4”

(207

6)

101/

4”(2

60)

83”(

2108

)83

3/4”

(212

7)85

3/4”

(217

8)

101/

4”(2

60)

1611

/16”

(424

)[2]

2011

/16”

(525

)[2]

2211

/16”

(576

)[2]

2411

/16”

(627

)[2]

2611

/16”

(678

)[2]

2711

/16”

(703

)[2]

3011

/16”

(779

)[2]

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 10: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-10

SINGLE UNITSWITH 15” TRANSOM

E

E

E

E

E

EE

25CDH2572-1T15

25CDH2576-1T15

25CDH2972-1T15 25CDH3372-1T15 25CDH3772-1T15

25CDH2976-1T15 25CDH3376-1T15 25CDH3776-1T15

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

20 1/16”(510)25 3/8”(645)26 1/8”(664)28 1/8”(714)

24 1/16”(611) 28 1/16”(716) 32 1/16”(814)29 3/8”(746)30 1/8”(765)32 1/8”(816)

33 3/8”(848)34 1/8”(867)36 1/8”(918)

37 3/8”(949)38 1/8”(968)

40 1/8”(1019)

87”(

2210

)87

3/4”

(222

9)89

3/4”

(228

0)

101/

4”(2

60)

91”(

2311

)91

3/4”

(233

0)93

3/4”

(238

1)

101/

4”(2

60)

3211

/16”

(830

)[2]

3411

/16”

(881

)[2]

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 11: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-11

SINGLE UNITSWITH 24” TRANSOM

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

E E E

E E

E E

20 1/16”(510)25 3/8”(645)26 1/8”(664)28 1/8”(714)

24 1/16”(611) 28 1/16”(716) 32 1/16”(814)29 3/8”(746)30 1/8”(765)32 1/8”(816)

33 3/8”(848)34 1/8”(867)36 1/8”(918)

37 3/8”(949)38 1/8”(968)

40 1/8”(1019)

25CDH2536-1T24 25CDH2936-1T24 25CDH3336-1T24 25CDH3736-1T24

25CDH2540-1T24 25CDH2940-1T24 25CDH3340-1T24 25CDH3740-1T24

25CDH2548-1T24 25CDH2948-1T24 25CDH3348-1T24 25CDH3748-1T24

25CDH2552-1T24 25CDH2952-1T24 25CDH3352-1T24 25CDH3752-1T24

25CDH2556-1T24 25CDH2956-1T24 25CDH3356-1T24 25CDH3756-1T24

25CDH2560-1T24 25CDH2960-1T24 25CDH3360-1T24 25CDH3760-1T24

25CDH2564-1T24 25CDH2964-1T24 25CDH3364-1T24 25CDH3764-1T24

1411

/16”

(373

)[2]

60”(

1524

)60

3/4”

(154

3)62

3/4”

(159

4)

191/

4”(4

89)

64”(

1626

)64

3/4”

(164

5)66

3/4”

(169

5)

191/

4”(4

89)

72”(

1829

)72

3/4”

(184

8)74

3/4”

(189

9)

191/

4”(4

89)

76”(

1930

)76

3/4”

(194

9)78

3/4”

(200

0)

191/

4”(4

89)

80”(

2032

)80

3/4”

(205

1)82

3/4”

(210

2)

191/

4”(4

89)

84”(

2134

)84

3/4”

(215

3)86

3/4”

(220

3)

191/

4”(4

89)

88”(

2235

)88

3/4”

(225

4)90

3/4”

(230

5)

191/

4”(4

89)

1611

/16”

(424

)[2]

2011

/16”

(525

)[2]

2211

/16”

(576

)[2]

2411

/16”

(627

)[2]

2611

/16”

(678

)[2]

2711

/16”

(703

)[2]

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 12: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-12

SINGLE UNITSWITH 24” TRANSOM

E E E E

E E E

E E E

25CDH2568-1T24 25CDH2968-1T24 25CDH3368-1T24 25CDH3768-1T24

25CDH2572-1T24 25CDH2972-1T24 25CDH3372-1T24 25CDH3772-1T24

25CDH2576-1T24 25CDH2976-1T24 25CDH3376-1T24 25CDH3776-1T24

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

20 1/16”(510)25 3/8”(645)26 1/8”(664)28 1/8”(714)

24 1/16”(611) 28 1/16”(716) 32 1/16”(814)29 3/8”(746)30 1/8”(765)32 1/8”(816)

33 3/8”(848)34 1/8”(867)36 1/8”(918)

37 3/8”(949)38 1/8”(968)

40 1/8”(1019)

92”(

2337

)92

3/4”

(235

6)94

3/4”

(240

7)

191/

4”(4

89)

96”(

2438

)96

3/4”

(245

7)98

3/4”

(250

8)

191/

4”(4

89)

100”

(254

0)10

03/

4”(2

559)

102

3/4”

(261

0)

191/

4”(4

89)

3011

/16”

(779

)[2]

3211

/16”

(830

)[2]

3411

/16”

(881

)[2]

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 13: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-13

SINGLE UNITS - NOMINALWITH 18” TRANSOM

25CDH2036N-1T18

25CDH2042N-1T18

25CDH2048N-1T18

25CDH2054N-1T18

25CDH2060N-1T18

25CDH2066N-1T18

25CDH2072N-1T18

25CDH2436N-1T18

25CDH2442N-1T18

25CDH2448N-1T18

25CDH2454N-1T18

25CDH2460N-1T18

25CDH2466N-1T18

25CDH2472N-1T18

25CDH2836N-1T18

25CDH2842N-1T18

25CDH2848N-1T18

25CDH2854N-1T18

25CDH2860N-1T18

25CDH2866N-1T18

25CDH2872N-1T18

25CDH3636N-1T18

25CDH3642N-1T18

25CDH3648N-1T18

25CDH3654N-1T18

25CDH3660N-1T18

25CDH3666N-1T18

25CDH3672N-1T18

E

E

E

E

E

E

E

13 15/16”(354)19 1/4”(489)

20”(508)22”(559)

17 15/16”(455) 21 15/16”(557) 29 15/16”(760)DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

23 1/4”(591)24”(610)26”(660)

27 1/4”(692)28”(711)30”(762)

35 1/4”(895)36”(914)38”(965)

145/

16”(

364)

[2]

531/

4”(1

353)

54”(

1372

)56

”(14

22)

131/

4”(3

37)

591/

4”(1

505)

60”(

1524

)62

”(15

75)

131/

4”(3

37)

651/

4”(1

657)

66”(

1676

)68

”(17

27)

131/

4”(3

37)

711/

4”(1

810)

72”(

1829

)74

”(18

80)

131/

4”(3

37)

771/

4”(1

962)

78”(

1981

)80

”(20

32)

131/

4”(3

37)

831/

4”(2

115)

84”(

2134

)86

”(21

84)

131/

4”(3

37)

891/

4”(2

267)

90”(

2286

)92

”(23

37)

131/

4”(3

37)

175/

16”(

440)

[2]

205/

16”(

515)

[2]

235/

16”(

592)

[2]

265/

16”(

668)

[2]

295/

16”(

745)

[2]

325/

16”(

821)

[2]

N INDICATES NOMINALSIZING.

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 14: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-14

TWIN UNITS

1411

/16”

(373

)[2]

36”(

914)

363/

4”(9

33)

383/

4”(9

84)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

40”(

1016

)40

3/4”

(103

5)42

3/4”

(108

6)

48”(

1219

)48

3/4”

(123

8)50

3/4”

(128

9)

52”(

1321

)52

3/4”

(134

0)54

3/4”

(139

1)

56”(

1441

)56

3/4”

(144

1)58

3/4”

(149

2)

1543

”(xx

xx)

603/

4”(1

543)

623/

4”(1

594)

64”(

1626

)64

3/4”

(164

5)66

3/4”

(169

5)

68”(

1727

)68

3/4”

(174

6)70

3/4”

(179

7)

72”(

1829

)72

3/4”

(184

8)74

3/4”

(189

9)

76”(

1930

)76

3/4”

(194

9)78

3/4”

(200

0)

16 1/16”(408)[2]42 3/4”(1086)43 1/2”(1105)45 1/2”(1156)

20 1/16”(510)[2]50 3/4”(1289)51 1/2”(1308)53 1/2”(1359)

24 1/16”(611)[2]58 3/4”(1492)59 1/2”(1511)61 1/2”(1562)

28 1/16”(713)[2]66 3/4”(1696)67 1/2”(1715)69 1/2”(1765)

32 1/16”(814)[2]74 3/4”(1899)75 1/2”(1918)77 1/2”(1969)

36 1/16”(916)[2]82 3/4”(2102)83 1/2”(2121)85 1/2”(2172)

25CDH2136-2

25CDH2140-2

25CDH2148-2

25CDH2152-2

25CDH2156-2

25CDH2160-2

25CDH2164-2

25CDH2168-2

25CDH2172-2

25CDH2176-2

25CDH2536-2

25CDH2540-2

25CDH2548-2

25CDH2552-2

25CDH2556-2

25CDH2560-2

25CDH2564-2

25CDH2568-2

25CDH2572-2

25CDH2576-2

25CDH2936-2

25CDH2940-2

25CDH2948-2

25CDH2952-2

25CDH2956-2

25CDH2960-2

25CDH2964-2

25CDH2968-2

25CDH2972-2

25CDH2976-2

25CDH3336-2

25CDH3340-2

25CDH3348-2

25CDH3352-2

25CDH3356-2

25CDH3360-2

25CDH3364-2

25CDH3368-2

25CDH3372-2

25CDH3376-2

25CDH3736-2

25CDH3740-2

25CDH3748-2

25CDH3752-2

25CDH3756-2

25CDH3760-2

25CDH3764-2

25CDH3768-2

25CDH3772-2

25CDH3776-2

25CDH4136-2

25CDH4140-2

25CDH4148-2

25CDH4152-2

25CDH4156-2

25CDH4160-2

25CDH4164-2

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

1611

/16”

(424

)[2]

2011

/16”

(525

)[2]

2211

/16”

(576

)[2]

2411

/16”

(627

)[2]

2611

/16”

(678

)[2]

2711

/16”

(703

)[2]

3011

/16”

(779

)[2]

3211

/16”

(830

)[2]

3411

/16”

(881

)[2]

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 15: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-15

TWIN UNITS - NOMINAL

25CDH2036N-2 25CDH2436N-2 25CDH2836N-2 25CDH3236N-2 25CDH3636N-2

25CDH2042N-2 25CDH2442N-2 25CDH2842N-2 25CDH3242N-2 25CDH3642N-2

25CDH2048N-2 25CDH2448N-2 25CDH2848N-2 25CDH3248N-2 25CDH3648N-2

25CDH2054N-2 25CDH2454N-2 25CDH2854N-2 25CDH3254N-2 25CDH3654N-2

25CDH2060N-2 25CDH2460N-2 25CDH2860N-2 25CDH3260N-2 25CDH3660N-2

25CDH2066N-2 25CDH2466N-2 25CDH2866N-2 25CDH3266N-2 25CDH3666N-2

25CDH2072N-2 25CDH2472N-2 25CDH2872N-2 25CDH3272N-2 25CDH3672N-2

13 15/16”(354)[2]39 1/4”(997)40”(1016)42”(1067)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

17 15/16”(455)[2]47 1/4”(1200)

48”(1219)50”(1270)

21 15/16”(557)[2]55 1/4”(1403)

56”(1422)58”(1473)

25 15/16”(659)[2]63 1/4”(1607)

64”(1626)66”(1676)

29 15/16”(760)[2]71 1/4”(1810)

72”(1829)74”(1880)

145/

16”(

364)

[2]

351/

4”(8

95)

36”(

914)

38”(

965)

411/

4”(1

048)

42”(

1067

)44

”(11

18)

471/

4”(1

200)

48”(

1219

)50

”(12

70)

531/

4”(1

353)

54”(

1372

)56

”(14

22)

591/

4”(1

505)

60”(

1524

)62

”(15

75)

651/

4”(1

657)

66”(

1676

)68

”(17

27)

711/

4”(1

810)

72”(

1829

)74

”(18

80)

EEE

EE

EE

175/

16”(

440)

[2]

205/

16”(

515)

[2]

235/

16”(

592)

[2]

265/

16”(

668)

[2]

295/

16”(

745)

[2]

325/

16”(

821)

[2]

N INDICATES NOMINALSIZING.

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 16: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-16

TWIN UNITSWITH 15” TRANSOM

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

E

20 1/16”(510)[2]50 3/4”(1289)51 1/2”(1308)53 1/2”(1259)

24 1/16”(611)[2]58 3/4”(1492)59 1/2”(1511)61 1/2”(1562)

28 1/16”(716)[2]66 3/4”(1695)67 1/2”(1715)69 1/2”(1765)

32 1/16”(814)[2]74 3/4”(1899)75 1/2”(1918)77 1/2”(1969)

1411

/16”

(373

)[2]

51”(

1295

)51

3/4”

(131

4)53

3/4”

(136

5)

101/

4”(2

60)

55”(

1397

)55

3/4”

(141

6)57

3/4”

(146

7)

101/

4”(2

60)

63”(

1600

)63

3/4”

(161

9)65

3/4”

(167

0)

101/

4”(2

60)

67”(

1702

)67

3/4”

(172

1)69

3/4”

(177

2)

101/

4”(2

60)

71”(

1803

)71

3/4”

(182

2)73

3/4”

(187

3)

101/

4”(2

60)

75”(

1905

)75

3/4”

(192

4)77

3/4”

(197

5)

101/

4”(2

60)

79”(

2007

)79

3/4”

(202

6)81

3/4”

(207

6)

101/

4”(2

60)

83”(

2108

)83

3/4”

(212

7)85

3/4”

(217

8)

101/

4”(2

60)

25CDH2536-2A15 25CDH2936-2A15 25CDH3336-2A15 25CDH3736-2A15

25CDH2540-2A15 25CDH2940-2A15 25CDH3340-2A15 25CDH3740-2A15

25CDH2548-2A15 25CDH2948-2A15 25CDH3348-2A15 25CDH3748-2A15

25CDH2552-2A15 25CDH2952-2A15 25CDH3352-2A15 25CDH3752-2A15

25CDH2556-2A15 25CDH2956-2A15 25CDH3356-2A15 25CDH3756-2A15

25CDH2560-2A15 25CDH2960-2A15 25CDH3360-2A15 25CDH3760-2A15

25CDH2564-2A15 25CDH2964-2A15 25CDH3364-2A15 25CDH3764-2A15

25CDH2568-2A15 25CDH2968-2A15 25CDH3368-2A15 25CDH3768-2A15

E

E E

E E

E EE

E

1611

/16”

(424

)[2]

2011

/16”

(525

)[2]

2211

/16”

(576

)[2]

2411

/16”

(627

)[2]

2611

/16”

(678

)[2]

2711

/16”

(703

)[2]

3011

/16”

(779

)[2]

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 17: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-17

TWIN UNITSWITH 15” TRANSOM

87”(

2210

)87

3/4”

(222

9)89

3/4”

(228

0)

101/

4”(2

60)

91”(

2311

)91

3/4”

(233

0)93

3/4”

(238

1)

101/

4”(2

60)

25CDH2572-2A15 25CDH2972-2A15 25CDH3372-2A15 25CDH3772-2A15

25CDH2576-2A15 25CDH2976-2A15 25CDH3376-2A15 25CDH3776-2A15

E E

E EEE

E

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

20 1/16”(510)[2]50 3/4”(1289)51 1/2”(1308)53 1/2”(1259)

24 1/16”(611)[2]58 3/4”(1492)59 1/2”(1511)61 1/2”(1562)

28 1/16”(716)[2]66 3/4”(1695)67 1/2”(1715)69 1/2”(1765)

32 1/16”(814)[2]74 3/4”(1899)75 1/2”(1918)77 1/2”(1969)

3211

/16”

(830

)[2]

3411

/16”

(881

)[2]

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 18: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-18

TWIN UNITSWITH 24” TRANSOM

E

25CDH2536-2A24 25CDH2936-2A24 25CDH3336-2A24 25CDH3736-2A24

25CDH2540-2A24 25CDH2940-2A24 25CDH3340-2A24 25CDH3740-2A24

25CDH2548-2A24 25CDH2948-2A24 25CDH3348-2A24 25CDH3748-2A24

25CDH2552-2A24 25CDH2952-2A24 25CDH3352-2A24 25CDH3752-2A24

25CDH2556-2A24 25CDH2956-2A24 25CDH3356-2A24 25CDH3756-2A24

25CDH2560-2A24 25CDH2960-2A24 25CDH3360-2A24 25CDH3760-2A24

25CDH2564-2A24 25CDH2964-2A24 25CDH3364-2A24 25CDH3764-2A24

E

E E

E EE

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

20 1/16”(510)[2]50 3/4”(1289)51 1/2”(1308)53 1/2”(1259)

24 1/16”(611)[2]58 3/4”(1492)59 1/2”(1511)61 1/2”(1562)

28 1/16”(716)[2]66 3/4”(1695)67 1/2”(1715)69 1/2”(1765)

32 1/16”(814)[2]74 3/4”(1899)75 1/2”(1918)77 1/2”(1969)

1411

/16”

(373

)[2]

60”(

1524

)60

3/4”

(154

3)62

3/4”

(159

4)

191/

4”(4

89)

64”(

1626

)64

3/4”

(164

5)66

3/4”

(169

5)

191/

4”(4

89)

72”(

1829

)72

3/4”

(184

8)74

3/4”

(189

9)

191/

4”(4

89)

76”(

1930

)76

3/4”

(194

9)78

3/4”

(200

0)

191/

4”(4

89)

80”(

2032

)80

3/4”

(205

1)82

3/4”

(210

2)

191/

4”(4

89)

84”(

2134

)84

3/4”

(215

3)86

3/4”

(220

3)

191/

4”(4

89)

88”(

2235

)88

3/4”

(225

4)90

3/4”

(230

5)

191/

4”(4

89)

1611

/16”

(424

)[2]

2011

/16”

(525

)[2]

2211

/16”

(576

)[2]

2411

/16”

(627

)[2]

2611

/16”

(678

)[2]

2711

/16”

(703

)[2]

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 19: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-19

TWIN UNITSWITH 24” TRANSOM

25CDH2568-2A24 25CDH2968-2A24 25CDH3368-2A24 25CDH3768-2A24

25CDH2572-2A24 25CDH2972-2A24 25CDH3372-2A24 25CDH3772-2A24

25CDH2576-2A24 25CDH2976-2A24 25CDH3376-2A24 25CDH3776-2A24

E E

E E

E EEE

E

E

92”(

2337

)92

3/4”

(235

6)94

3/4”

(240

7)

191/

4”(4

89)

96”(

2438

)96

3/4”

(245

7)98

3/4”

(250

8)

191/

4”(4

89)

100”

(254

0)10

03/

4”(2

559)

102

3/4”

(261

0)

191/

4”(4

89)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

20 1/16”(510)[2]50 3/4”(1289)51 1/2”(1308)53 1/2”(1259)

24 1/16”(611)[2]58 3/4”(1492)59 1/2”(1511)61 1/2”(1562)

28 1/16”(716)[2]66 3/4”(1695)67 1/2”(1715)69 1/2”(1765)

32 1/16”(814)[2]74 3/4”(1899)75 1/2”(1918)77 1/2”(1969)

3011

/16”

(779

)[2]

3211

/16”

(830

)[2]

3411

/16”

(881

)[2]

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 20: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-20

TWIN UNITS - NOMINALWITH 18” TRANSOM

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

25CDH2036N-2A18 25CDH2436N-2A18 25CDH2836N-2A18 25CDH3636N-2A18

25CDH2042N-2A18 25CDH2442N-2A18 25CDH2842N-2A18 25CDH3642N-2A18

25CDH2048N-2A18 25CDH2448N-2A18 25CDH2848N-2A18 25CDH3648N-2A18

25CDH2054N-2A18 25CDH2454N-2A18 25CDH2854N-2A18 25CDH3654N-2A18

25CDH2060N-2A18 25CDH2460N-2A18 25CDH2860N-2A18 25CDH3660N-2A18

25CDH2066N-2A18 25CDH2466N-2A18 25CDH2866N-2A18 25CDH3666N-2A18

25CDH2072N-2A18 25CDH2472N-2A18 25CDH2872N-2A18 25CDH3672N-2A18

145/

16”(

364)

[2]

531/

4”(1

353)

54”(

1372

)56

”(14

22)

131/

4”(3

37)

591/

4”(1

505)

60”(

1524

)62

”(15

75)

131/

4”(3

37)

651/

4”(1

657)

66”(

1676

)68

”(17

27)

131/

4”(3

37)

711/

4”(1

810)

72”(

1829

)74

”(18

80)

131/

4”(3

37)

771/

4”(1

962)

78”(

1981

)80

”(20

32)

131/

4”(3

37)

831/

4”(2

115)

84”(

2134

)86

”(21

84)

131/

4”(3

37)

891/

4”(2

267)

90”(

2286

)92

”(23

37)

131/

4”(3

37)

13 15/16”(354)[2]39 1/4”(997)40”(1016)42”(1067)

EEE

EE

EE

17 15/16”(455)[2]47 1/4”(1200)

48”(1219)50”(1270)

21 15/16”(557)[2]55 1/4”(1403)

56”(1422)58”(1473)

29 15/16”(760)[2]71 1/4”(1810)

72”(1829)74”(1880)

175/

16”(

440)

[2]

205/

16”(

515)

[2]

235/

16”(

592)

[2]

265/

16”(

668)

[2]

295/

16”(

745)

[2]

325/

16”(

821)

[2]

N INDICATES NOMINALSIZING.

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 21: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-21

TRIPLE UNITS

E

16 1/16”(408)[3]64 1/8”(1629)64 7/8”(1648)66 7/8”(1699)

25CDH2136-3 25CDH2536-3 25CDH2936-3 25CDH3336-3 25CDH3736-3

25CDH2140-3 25CDH2540-3 25CDH2940-3 25CDH3340-3 25CDH3740-3

25CDH2148-3 25CDH2548-3 25CDH2948-3 25CDH3348-3 25CDH3748-3

25CDH2152-3 25CDH2552-3 25CDH2952-3 25CDH3352-3 25CDH3752-3

25CDH2156-3 25CDH2556-3 25CDH2956-3 25CDH3356-3 25CDH3756-3

25CDH2160-3 25CDH2560-3 25CDH2960-3 25CDH3360-3 25CDH3760-3

25CDH2164-3 25CDH2564-3 25CDH2964-3 25CDH3364-3 25CDH3764-3

25CDH2168-3 25CDH2568-3 25CDH2968-3 25CDH3368-3 25CDH3768-3

25CDH2172-3 25CDH2572-3 25CDH2972-3 25CDH3372-3 25CDH3772-3

25CDH2176-3 25CDH2576-3 25CDH2976-3 25CDH3376-3 25CDH3776-3

20 1/16”(510)[3]76 1/8”(1934)76 7/8”(1953)78 7/8”(2003)

24 1/16”(611)[3]88 1/8”(2238)88 7/8”(2257)90 7/8”(2308)

28 1/16”(713)[3]100 1/8”(2543)100 7/8”(2562)102 7/8”(2613)

32 1/16”(814)[3]112 1/8”(2848)112 7/8”(2867)114 7/8”(2918)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

EE E

EEE

EEE

EEE

EE

EE

1411

/16”

(373

)[2]

36”(

914)

363/

4”(9

33)

383/

4”(9

84)

40”(

1016

)40

3/4”

(103

5)42

3/4”

(108

6)

48”(

1219

)48

3/4”

(123

8)50

3/4”

(128

9)

52”(

1321

)52

3/4”

(134

0)54

3/4”

(139

1)

56”(

1441

)56

3/4”

(144

1)58

3/4”

(149

2)

1543

”(xx

xx)

603/

4”(1

543)

623/

4”(1

594)

64”(

1626

)64

3/4”

(164

5)66

3/4”

(169

5)

68”(

1727

)68

3/4”

(174

6)70

3/4”

(179

7)

72”(

1829

)72

3/4”

(184

8)74

3/4”

(189

9)

76”(

1930

)76

3/4”

(194

9)78

3/4”

(200

0)

1611

/16”

(424

)[2]

2011

/16”

(525

)[2]

2211

/16”

(576

)[2]

2411

/16”

(627

)[2]

2611

/16”

(678

)[2]

2711

/16”

(703

)[2]

3011

/16”

(779

)[2]

3211

/16”

(830

)[2]

3411

/16”

(881

)[2]

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 22: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-22

TRIPLE UNITS

25CDH4136-3

25CDH4140-3

25CDH4148-3

25CDH4152-3

25CDH4156-3

25CDH4160-3

25CDH4164-3

36 1/16”(916)[3]124 1/8”(3153)124 7/8”(3172)126 7/8”(3223)

E

E

E

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

1411

/16”

(373

)[2]

36”(

914)

363/

4”(9

33)

383/

4”(9

84)

40”(

1016

)40

3/4”

(103

5)42

3/4”

(108

6)

48”(

1219

)48

3/4”

(123

8)50

3/4”

(128

9)

52”(

1321

)52

3/4”

(134

0)54

3/4”

(139

1)

56”(

1441

)56

3/4”

(144

1)58

3/4”

(149

2)

1543

”(xx

xx)

603/

4”(1

543)

623/

4”(1

594)

64”(

1626

)64

3/4”

(164

5)66

3/4”

(169

5)

1611

/16”

(424

)[2]

2011

/16”

(525

)[2]

2211

/16”

(576

)[2]

2411

/16”

(627

)[2]

2611

/16”

(678

)[2]

2711

/16”

(703

)[2]

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 23: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-23

TRIPLE UNITS - NOMINAL

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

E

E

E

E

E

E

E

25CDH2036N-3

25CDH2042N-3

25CDH2048N-3

25CDH2054N-3

25CDH2060N-3

25CDH2066N-3

25CDH2072N-3

25CDH2436N-3

25CDH2442N-3

25CDH2448N-3

25CDH2454N-3

25CDH2460N-3

25CDH2466N-3

25CDH2472N-3

25CDH2836N-3

25CDH2842N-3

25CDH2848N-3

25CDH2854N-3

25CDH2860N-3

25CDH2866N-3

25CDH2872N-3

25CDH3236N-3

25CDH3242N-3

25CDH3248N-3

25CDH3254N-3

25CDH3260N-3

25CDH3266N-3

25CDH3272N-3

25CDH3636N-3

25CDH3642N-3

25CDH3648N-3

25CDH3654N-3

25CDH3660N-3

25CDH3666N-3

25CDH3672N-3

13 15/16”(354)[3]59 1/4”(1505)

60”(1524)62”(1575)

17 15/16”(455)[3]71 1/4”(1810)

72”(1829)74”(1880)

21 15/16”(557)[3]83 1/4”(2115)

84”(2134)86”(2184)

25 15/16”(659)[3]95 1/4”(2419)

96”(2438)98”(2489)

29 15/16”(760)[3]107 1/4”(2724)

108”(2743)110”(2794)

145/

16”(

364)

[2]

351/

4”(8

95)

36”(

914)

38”(

965)

411/

4”(1

048)

42”(

1067

)44

”(11

18)

471/

4”(1

200)

48”(

1219

)50

”(12

70)

531/

4”(1

353)

54”(

1372

)56

”(14

22)

591/

4”(1

505)

60”(

1524

)62

”(15

75)

651/

4”(1

657)

66”(

1676

)68

”(17

27)

711/

4”(1

810)

72”(

1829

)74

”(18

80)

175/

16”(

440)

[2]

205/

16”(

515)

[2]

235/

16”(

592)

[2]

265/

16”(

668)

[2]

295/

16”(

745)

[2]

325/

16”(

821)

[2]

N INDICATES NOMINALSIZING.

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 24: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-24

TRIPLE UNITSWITH 15” TRANSOM

E

E

E

E

E

E

E

E

E

E

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

25CDH2536-3A15 25CDH2936-3A15 25CDH3336-3A15 25CDH3736-3A15

25CDH2540-3A15 25CDH2940-3A15 25CDH3340-3A15 25CDH3740-3A15

25CDH2548-3A15 25CDH2948-3A15 25CDH3348-3A15 25CDH3748-3A15

25CDH2552-3A15 25CDH2952-3A15 25CDH3352-3A15 25CDH3752-3A15

25CDH2556-3A15 25CDH2956-3A15 25CDH3356-3A15 25CDH3756-3A15

25CDH2560-3A15 25CDH2960-3A15 25CDH3360-3A15 25CDH3760-3A15

25CDH2564-3A15 25CDH2964-3A15 25CDH3364-3A15 25CDH3764-3A15

25CDH2568-3A15 25CDH2968-3A15 25CDH3368-3A15 25CDH3768-3A15

20 1/16”(510)[3]76 1/8”(1934)76 7/8”(1953)78 7/8”(2003)

24 1/16”(611)[3] 28 1/16”(716)[3] 32 1/16”(814)[3]88 1/8”(2238)88 7/8”(2257)90 7/8”(2308)

100 1/8”(2543)100 7/8”(2562)102 7/8”(2613)

112 1/8”(2848)112 7/8”(2867)114 7/8”(2918)

1411

/16”

(373

)[2]

51”(

1295

)51

3/4”

(131

4)53

3/4”

(136

5)

101/

4”(2

60)

55”(

1397

)55

3/4”

(141

6)57

3/4”

(146

7)

101/

4”(2

60)

63”(

1600

)63

3/4”

(161

9)65

3/4”

(167

0)

101/

4”(2

60)

67”(

1702

)67

3/4”

(172

1)69

3/4”

(177

2)

101/

4”(2

60)

71”(

1803

)71

3/4”

(182

2)73

3/4”

(187

3)

101/

4”(2

60)

75”(

1905

)75

3/4”

(192

4)77

3/4”

(197

5)

101/

4”(2

60)

79”(

2007

)79

3/4”

(202

6)81

3/4”

(207

6)

101/

4”(2

60)

83”(

2108

)83

3/4”

(212

7)85

3/4”

(217

8)

101/

4”(2

60)

1611

/16”

(424

)[2]

2011

/16”

(525

)[2]

2211

/16”

(576

)[2]

2411

/16”

(627

)[2]

2611

/16”

(678

)[2]

2711

/16”

(703

)[2]

3011

/16”

(779

)[2]

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 25: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-25

TRIPLE UNITSWITH 15” TRANSOM

E

E

E

E

E

EE

25CDH2572-3A15 25CDH2972-3A15 25CDH3372-3A15 25CDH3772-3A15

25CDH2576-3A15 25CDH2976-3A15 25CDH3376-3A15 25CDH3776-3A15

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

20 1/16”(510)[3]76 1/8”(1934)76 7/8”(1953)78 7/8”(2003)

24 1/16”(611)[3] 28 1/16”(716)[3] 32 1/16”(814)[3]88 1/8”(2238)88 7/8”(2257)90 7/8”(2308)

100 1/8”(2543)100 7/8”(2562)102 7/8”(2613)

112 1/8”(2848)112 7/8”(2867)114 7/8”(2918)

87”(

2210

)87

3/4”

(222

9)89

3/4”

(228

0)

101/

4”(2

60)

91”(

2311

)91

3/4”

(233

0)93

3/4”

(238

1)

101/

4”(2

60)

3211

/16”

(830

)[2]

3411

/16”

(881

)[2]

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 26: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-26

TRIPLE UNITSWITH 24” TRANSOM

E

E

E

E

E

EE

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

25CDH2536-3A24 25CDH2936-3A24 25CDH3336-3A24 25CDH3736-3A24

25CDH2540-3A24 25CDH2940-3A24 25CDH3340-3A24 25CDH3740-3A24

25CDH2548-3A24 25CDH2948-3A24 25CDH3348-3A24 25CDH3748-3A24

25CDH2552-3A24 25CDH2952-3A24 25CDH3352-3A24 25CDH3752-3A24

25CDH2556-3A24 25CDH2956-3A24 25CDH3356-3A24 25CDH3756-3A24

25CDH2560-3A24 25CDH2960-3A24 25CDH3360-3A24 25CDH3760-3A24

25CDH2564-3A24 25CDH2964-3A24 25CDH3364-3A24 25CDH3764-3A24

20 1/16”(510)[3]76 1/8”(1934)76 7/8”(1953)78 7/8”(2003)

24 1/16”(611)[3] 28 1/16”(716)[3] 32 1/16”(814)[3]88 1/8”(2238)88 7/8”(2257)90 7/8”(2308)

100 1/8”(2543)100 7/8”(2562)102 7/8”(2613)

112 1/8”(2848)112 7/8”(2867)114 7/8”(2918)

1411

/16”

(373

)[2]

60”(

1524

)60

3/4”

(154

3)62

3/4”

(159

4)

191/

4”(4

89)

64”(

1626

)64

3/4”

(164

5)66

3/4”

(169

5)

191/

4”(4

89)

72”(

1829

)72

3/4”

(184

8)74

3/4”

(189

9)

191/

4”(4

89)

76”(

1930

)76

3/4”

(194

9)78

3/4”

(200

0)

191/

4”(4

89)

80”(

2032

)80

3/4”

(205

1)82

3/4”

(210

2)

191/

4”(4

89)

84”(

2134

)84

3/4”

(215

3)86

3/4”

(220

3)

191/

4”(4

89)

88”(

2235

)88

3/4”

(225

4)90

3/4”

(230

5)

191/

4”(4

89)

1611

/16”

(424

)[2]

2011

/16”

(525

)[2]

2211

/16”

(576

)[2]

2411

/16”

(627

)[2]

2611

/16”

(678

)[2]

2711

/16”

(703

)[2]

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 27: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-27

TRIPLE UNITSWITH 24” TRANSOM

E

E

E

E

E

E

E

E

EE

25CDH2568-3A24 25CDH2968-3A24 25CDH3368-3A24 25CDH3768-3A24

25CDH2572-3A24 25CDH2972-3A24 25CDH3372-3A24 25CDH3772-3A24

25CDH2576-3A24 25CDH2976-3A24 25CDH3376-3A24 25CDH3776-3A24

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

20 1/16”(510)[3]76 1/8”(1934)76 7/8”(1953)78 7/8”(2003)

24 1/16”(611)[3] 28 1/16”(716)[3] 32 1/16”(814)[3]88 1/8”(2238)88 7/8”(2257)90 7/8”(2308)

100 1/8”(2543)100 7/8”(2562)102 7/8”(2613)

112 1/8”(2848)112 7/8”(2867)114 7/8”(2918)

92”(

2337

)92

3/4”

(235

6)94

3/4”

(240

7)

191/

4”(4

89)

96”(

2438

)96

3/4”

(245

7)98

3/4”

(250

8)

191/

4”(4

89)

100”

(254

0)10

03/

4”(2

559)

102

3/4”

(261

0)

191/

4”(4

89)

3011

/16”

(779

)[2]

3211

/16”

(830

)[2]

3411

/16”

(881

)[2]

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 28: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-28

TRIPLE UNITS - NOMINALWITH 18” TRANSOM

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

25CDH2036N-3A18

25CDH2042N-3A18

25CDH2048N-3A18

25CDH2054N-3A18

25CDH2060N-3A18

25CDH2066N-3A18

25CDH2072N-3A18

25CDH2436N-3A18 25CDH2836N-3A18 25CDH3636N-3A18

25CDH2442N-3A18 25CDH2842N-3A18 25CDH3642N-3A18

25CDH2448N-3A18 25CDH2848N-3A18 25CDH3648N-3A18

25CDH2454N-3A18 25CDH2854N-3A18 25CDH3654N-3A18

25CDH2460N-3A18 25CDH2860N-3A18 25CDH3660N-3A18

25CDH2466N-3A18 25CDH2866N-3A18 25CDH3666N-3A18

25CDH2472N-3A18 25CDH2872N-3A18 25CDH3672N-3A18

13 15/16”(354)[3]59 1/4”(1505)

60”(1524)62”(1575)

17 15/16”(455)[3] 21 15/16”(557)[3] 29 15/16”(760)[3]

E

E

E

E

E

E

E

71 1/4”(1810)72”(1829)74”(1880)

83 1/4”(2115)84”(2134)86”(2184)

107 1/4”(2724)108”(2743)110”(2794)

145/

16”(

364)

[2]

531/

4”(1

353)

54”(

1372

)56

”(14

22)

131/

4”(3

37)

591/

4”(1

505)

60”(

1524

)62

”(15

75)

131/

4”(3

37)

651/

4”(1

657)

66”(

1676

)68

”(17

27)

131/

4”(3

37)

711/

4”(1

810)

72”(

1829

)74

”(18

80)

131/

4”(3

37)

771/

4”(1

962)

78”(

1981

)80

”(20

32)

131/

4”(3

37)

831/

4”(2

115)

84”(

2134

)86

”(21

84)

131/

4”(3

37)

891/

4”(2

267)

90”(

2286

)92

”(23

37)

131/

4”(3

37)

175/

16”(

440)

[2]

205/

16”(

515)

[2]

235/

16”(

592)

[2]

265/

16”(

668)

[2]

295/

16”(

745)

[2]

325/

16”(

821)

[2]

N INDICATES NOMINALSIZING.

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 29: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-29

4 WIDE UNITS

16 1/16”(408)[4]85 1/2”(2172)86 1/4”(2191)88 1/4”(2242)

25CDH2136-4 25CDH2536-4 25CDH2936-4 25CDH3336-4

25CDH2140-4 25CDH2540-4 25CDH2940-4 25CDH3340-4

25CDH2148-4 25CDH2548-4 25CDH2948-4 25CDH3348-4

25CDH2152-4 25CDH2552-4 25CDH2952-4 25CDH3352-4

25CDH2156-4 25CDH2556-4 25CDH2956-4 25CDH3356-4

25CDH2160-4 25CDH2560-4 25CDH2960-4 25CDH3360-4

25CDH2164-4 25CDH2564-4 25CDH2964-4 25CDH3364-4

25CDH2168-4 25CDH2568-4 25CDH2968-4 25CDH3368-4

25CDH2172-4 25CDH2572-4 25CDH2972-4 25CDH3372-4

25CDH2176-4 25CDH2576-4 25CDH2976-4 25CDH3376-4

20 1/16”(510)[4]101 1/2”(2578)102 1/4”(2597)104 1/4”(2648)

24 1/16”(611)[4]117 1/2”(2985)118 1/4”(3004)120 1/4”(3054)

28 1/16”(713)[4]133 1/2”(3391)134 1/4”(3410)136 1/4”(3461)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

EEE

EE

EE

EE

E

E

1411

/16”

(373

)[2]

36”(

914)

363/

4”(9

33)

383/

4”(9

84)

40”(

1016

)40

3/4”

(103

5)42

3/4”

(108

6)

48”(

1219

)48

3/4”

(123

8)50

3/4”

(128

9)

52”(

1321

)52

3/4”

(134

0)54

3/4”

(139

1)

56”(

1441

)56

3/4”

(144

1)58

3/4”

(149

2)

1543

”(xx

xx)

603/

4”(1

543)

623/

4”(1

594)

64”(

1626

)64

3/4”

(164

5)66

3/4”

(169

5)

68”(

1727

)68

3/4”

(174

6)70

3/4”

(179

7)

72”(

1829

)72

3/4”

(184

8)74

3/4”

(189

9)

76”(

1930

)76

3/4”

(194

9)78

3/4”

(200

0)

1611

/16”

(424

)[2]

2011

/16”

(525

)[2]

2211

/16”

(576

)[2]

2411

/16”

(627

)[2]

2611

/16”

(678

)[2]

2711

/16”

(703

)[2]

3011

/16”

(779

)[2]

3211

/16”

(830

)[2]

3411

/16”

(881

)[2]

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 30: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-30

4 WIDE UNITS

25CDH3736-4

25CDH3740-4

25CDH3748-4

25CDH3752-4

25CDH3756-4

25CDH3760-4

25CDH3764-4

25CDH3768-4

25CDH3772-4

25CDH3776-4

32 1/16”(814)[4]149 1/2”(3797)150 1/4”(3816)152 1/4”(3867)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

E

E

E

E

E

E

1411

/16”

(373

)[2]

36”(

914)

363/

4”(9

33)

383/

4”(9

84)

40”(

1016

)40

3/4”

(103

5)42

3/4”

(108

6)

48”(

1219

)48

3/4”

(123

8)50

3/4”

(128

9)

52”(

1321

)52

3/4”

(134

0)54

3/4”

(139

1)

56”(

1441

)56

3/4”

(144

1)58

3/4”

(149

2)

1543

”(xx

xx)

603/

4”(1

543)

623/

4”(1

594)

64”(

1626

)64

3/4”

(164

5)66

3/4”

(169

5)

68”(

1727

)68

3/4”

(174

6)70

3/4”

(179

7)

72”(

1829

)72

3/4”

(184

8)74

3/4”

(189

9)

76”(

1930

)76

3/4”

(194

9)78

3/4”

(200

0)

1611

/16”

(424

)[2]

2011

/16”

(525

)[2]

2211

/16”

(576

)[2]

2411

/16”

(627

)[2]

2611

/16”

(678

)[2]

2711

/16”

(703

)[2]

3011

/16”

(779

)[2]

3211

/16”

(830

)[2]

3411

/16”

(881

)[2]

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 31: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-31

5 WIDE UNITS

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

16 1/16”(408)[5]106 7/8”(2715)107 5/8”(2734)109 5/8”(2785)

25CDH2136-5

25CDH2140-5

25CDH2148-5

25CDH2152-5

25CDH2156-5

25CDH2160-5

25CDH2164-5

25CDH2168-5

25CDH2172-5

25CDH2176-5

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

25CDH2536-5

25CDH2540-5

25CDH2548-5

25CDH2552-5

25CDH2556-5

25CDH2560-5

25CDH2564-5

25CDH2568-5

25CDH2572-5

25CDH2576-5

25CDH2936-5

25CDH2940-5

25CDH2948-5

25CDH2952-5

25CDH2956-5

25CDH2960-5

25CDH2964-5

25CDH2968-5

25CDH2972-5

25CDH2976-5

25CDH3336-5

25CDH3340-5

25CDH3348-5

25CDH3352-5

25CDH3356-5

25CDH3360-5

25CDH3364-5

25CDH3368-5

25CDH3372-5

25CDH3376-5

20 1/16”(510)[5]126 7/8”(3223)127 5/8”(3242)129 5/8”(3293)

24 1/16”(611)[5]146 7/8”(3731)147 5/8”(3750)149 5/8”(3801)

28 1/16”(713)[5]166 7/8”(4239)167 5/8”(4258)169 5/8”(4309)

1411

/16”

(373

)[2]

36”(

914)

363/

4”(9

33)

383/

4”(9

84)

40”(

1016

)40

3/4”

(103

5)42

3/4”

(108

6)

48”(

1219

)48

3/4”

(123

8)50

3/4”

(128

9)

52”(

1321

)52

3/4”

(134

0)54

3/4”

(139

1)

56”(

1441

)56

3/4”

(144

1)58

3/4”

(149

2)

1543

”(xx

xx)

603/

4”(1

543)

623/

4”(1

594)

64”(

1626

)64

3/4”

(164

5)66

3/4”

(169

5)

68”(

1727

)68

3/4”

(174

6)70

3/4”

(179

7)

72”(

1829

)72

3/4”

(184

8)74

3/4”

(189

9)

76”(

1930

)76

3/4”

(194

9)78

3/4”

(200

0)

1611

/16”

(424

)[2]

2011

/16”

(525

)[2]

2211

/16”

(576

)[2]

2411

/16”

(627

)[2]

2611

/16”

(678

)[2]

2711

/16”

(703

)[2]

3011

/16”

(779

)[2]

3211

/16”

(830

)[2]

3411

/16”

(881

)[2]

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 32: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-32

5 WIDE UNITS

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

25CDH3736-5

25CDH3740-5

25CDH3748-5

25CDH3752-5

25CDH3756-5

25CDH3760-5

25CDH3764-5

25CDH3768-5

25CDH3772-5

25CDH3776-5

32 1/16”(814)[5]186 7/8”(4747)187 5/8”(4766)189 5/8”(4817)

25CDH3736-5

25CDH3740-5

25CDH3748-5

25CDH3752-5

25CDH3756-5

25CDH3760-5

25CDH3764-5

25CDH3768-5

25CDH3772-5

25CDH3776-5

32 1/16”(814)[5]186 7/8”(4747)187 5/8”(4766)189 5/8”(4817)

1411

/16”

(373

)[2]

36”(

914)

363/

4”(9

33)

383/

4”(9

84)

40”(

1016

)40

3/4”

(103

5)42

3/4”

(108

6)

48”(

1219

)48

3/4”

(123

8)50

3/4”

(128

9)

52”(

1321

)52

3/4”

(134

0)54

3/4”

(139

1)

56”(

1441

)56

3/4”

(144

1)58

3/4”

(149

2)

1543

”(xx

xx)

603/

4”(1

543)

623/

4”(1

594)

64”(

1626

)64

3/4”

(164

5)66

3/4”

(169

5)

68”(

1727

)68

3/4”

(174

6)70

3/4”

(179

7)

72”(

1829

)72

3/4”

(184

8)74

3/4”

(189

9)

76”(

1930

)76

3/4”

(194

9)78

3/4”

(200

0)

1611

/16”

(424

)[2]

2011

/16”

(525

)[2]

2211

/16”

(576

)[2]

2411

/16”

(627

)[2]

2611

/16”

(678

)[2]

2711

/16”

(703

)[2]

3011

/16”

(779

)[2]

3211

/16”

(830

)[2]

3411

/16”

(881

)[2]

Double-Hung Windows

W-2500

SCALE: 1/8” = 1’

Page 33: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-33

ELEVATION DRAWINGS UTILIZE A LIMITED NUMBER OF PROJECTED LINES TO PRODUCE A RUDIMENTARY DRAWING INTENDEDTO BE USED IN A SMALL GRAPHICAL SCALE. ELEVATIONS ARE VIEWED PERPENDICULAR FROM THE EXTERIOR OF THESTRUCTURE. IF MORE DIMENSIONS ARE NEEDED, USE THE SECTION DRAWINGS FOR MORE COMPLETE DEPICTIONS.

1. ALL UNITS SHOWN ARE AVAILABLE AS STATIONARY ONLY.

2. UNIT ELEVATIONS ARE SHOWN WITHOUT EXTERIOR TRIM.

3. DIMENSIONAL VALUES IN BRACKETS ARE MILLIMETER CONVERSIONS.

GENERAL DOUBLE HUNG TRANSOM NOTES

25CDHP2124

ROUGH OPENINGDIMENSIONS ARE

IN BOLD TEXT.

M.O. Adams/Flat CasingRough Opening

M.O. Brickmould

Frame Size

Masonry Openings for Brickmould, Flat & Adams Casing.Vertical measurements include sillnose.(Subtract 1/2” from Masonry Opening for Unit Size)

OUTSIDE OFFRAME.

’25CDHP’ INDICATESW2500 CLAD DOUBLE HUNG TRANSOM

BOOK CODE

THE LAST TWO NUMBERS INDICATETHE UNITS HEIGHTTHE FIRST TWO NUMBERS

INDICATE THE UNIT WIDTH

SEE SYMBOL LEGEND BELOW

ELEVATION SYMBOL LEGEND:

NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITHSTANDARD GLAZING.

##

DAYLIGHT OPENING

24 7/8” ( 632 )27 7/8” ( 708 )21 3/8” ( 543 )17 3/4” (451)

27 1/16” ( 687 )28 9/16” ( 725 )24 3/4” ( 629 )24” ( 610 )20 3/8” ( 518 )

##

ELEVATION NOTESPICTURE UNITS

Double-Hung Windows

W-2500

Page 34: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-34

PICTURE UNITS

Note: Elevations shown DO NOT have exterior trim. For other Trim Options refer to the Unit Sizing, Rough Opening and Masonry Opening page.

25CDHP1212

6 3/4”(171)12”(305)

12 3/4”(324)14 3/4”(375)

12 3/4”(324)18”(457)

18 3/4”(476)20 3/4”(527)

18 3/4”(476)24”(610)

24 3/4”(629)26 3/4”(679)

24 3/4”(629)30”(762)

30 3/4”(781)32 3/4”(832)

30 3/4”(781)36”(914)

36 3/4”(933)38 3/4”(984)

34 3/4”(883)40”(1016)

40 3/4”(1035)42 3/4”(1086)

36 3/4”(933)42”(1067)

42 3/4”(1086)44 3/4”(1137)

12”(

305)

123/

4”(3

24)

143/

4”(3

75)

71/

4”(1

84)

18”(

457)

183/

4”(4

76)

203/

4”(5

27)

131/

4”(3

37)

24”(

610)

243/

4”(6

29)

263/

4”(6

79)

191/

4”(4

89)

30”(

762)

303/

4”(7

81)

323/

4”(8

32)

251/

4”(6

41)

36”(

914)

363/

4”(9

33)

383/

4”(9

84)

311/

4”(7

94)

40”(

1016

)40

3/4”

(103

5)42

3/4”

(108

6)

351/

4”(8

95)

42”(

1067

)42

3/4”

(108

6)44

3/4”

(113

7)

371/

4”(9

46)

48”(

1219

)48

3/4”

(123

8)50

3/4”

(128

9)

431/

4”(1

099)

25CDHP1812 25CDHP2412 25CDHP3012 25CDHP3612 25CDHP4012 25CDHP4212

25CDHP1218 25CDHP1818 25CDHP2418 25CDHP3018 25CDHP3618 25CDHP4018 25CDHP4218

25CDHP1224 25CDHP1824 25CDHP2424 25CDHP3024 25CDHP3624 25CDHP4024 25CDHP4224

25CDHP1230 25CDHP1830 25CDHP2430 25CDHP3030 25CDHP3630 25CDHP4030 25CDHP4230

25CDHP1236 25CDHP1836 25CDHP2436 25CDHP3036 25CDHP3636 25CDHP4036 25CDHP4236

25CDHP1240 25CDHP1840 25CDHP2440 25CDHP3040 25CDHP3640 25CDHP4040 25CDHP4240

25CDHP1242 25CDHP1842 25CDHP2442 25CDHP3042 25CDHP3642 25CDHP4042 25CDHP4242

25CDHP1248 25CDHP1848 25CDHP2448 25CDHP3048 25CDHP3648 25CDHP4048 25CDHP4248

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

ELEVATION SYMBOL LEGEND:

##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.VALUES IN () ARE IN MILLIMETER CONVERSIONS.

##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.

Double-Hung Windows

W-2500

SCALE: 1/4” = 1’

Page 35: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-35

PICTURE UNITS

54”(

1372

)54

3/4”

(139

1)56

3/4”

(144

1)

491/

4”(1

251)

56”(

1422

)56

3/4”

(144

1)58

3/4”

(149

2)

511/

4”(1

302)

60”(

1524

)62

3/4”

(159

4)64

3/4”

(164

5)

551/

4”(1

403)

64”(

1626

)64

3/4”

(164

5)66

3/4”

(169

5)

591/

4”(1

505)

68”(

1727

)68

3/4”

(174

6)70

3/4”

(179

7)

631/

4”(1

607)

25CDHP1254 25CDHP1854 25CDHP2454 25CDHP3054 25CDHP3654 25CDHP4054 25CDHP4254

25CDHP1256 25CDHP1856 25CDHP2456 25CDHP3056 25CDHP3656 25CDHP4056 25CDHP4256

25CDHP1260 25CDHP1860 25CDHP2460 25CDHP3060 25CDHP3660 25CDHP4060 25CDHP4260

25CDHP1264 25CDHP1864 25CDHP2464 25CDHP3064 25CDHP3664 25CDHP4064 25CDHP4264

25CDHP1268 25CDHP1868 25CDHP2468 25CDHP3068 25CDHP3668 25CDHP4068 25CDHP4268

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

6 3/4”(171)12”(305)

12 3/4”(324)14 3/4”(375)

12 3/4”(324)18”(457)

18 3/4”(476)20 3/4”(527)

18 3/4”(476)24”(610)

24 3/4”(629)26 3/4”(679)

24 3/4”(629)30”(762)

30 3/4”(781)32 3/4”(832)

30 3/4”(781)36”(914)

36 3/4”(933)38 3/4”(984)

34 3/4”(883)40”(1016)

40 3/4”(1035)42 3/4”(1086)

36 3/4”(933)42”(1067)

42 3/4”(1086)44 3/4”(1137)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

ELEVATION SYMBOL LEGEND:

##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.VALUES IN () ARE IN MILLIMETER CONVERSIONS.

##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

Double-Hung Windows

W-2500

SCALE: 1/4” = 1’

Page 36: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-36

PICTURE UNITS

72”(

1829

)72

3/4”

(184

8)74

3/4”

(189

9)

671/

4”(1

708)

76”(

1930

)76

3/4”

(194

9)78

3/4”

(200

0)

711/

4”(1

810)

88”(

2235

)88

3/4”

(225

4)90

3/4”

(230

5)

831/

4”(2

115)

25CDHP1272 25CDHP1872 25CDHP2472 25CDHP3072 25CDHP3672 25CDHP4072 25CDHP4272

25CDHP1276 25CDHP1876 25CDHP2476 25CDHP3076 25CDHP3676 25CDHP4076 25CDHP4276

25CDHP1288 25CDHP1888 25CDHP2488 25CDHP3088 25CDHP3688 25CDHP4088 25CDHP4288

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50*

35*50**

35*50**

35*50**

35*50**

6 3/4”(171)12”(305)

12 3/4”(324)14 3/4”(375)

12 3/4”(324)18”(457)

18 3/4”(476)20 3/4”(527)

18 3/4”(476)24”(610)

24 3/4”(629)26 3/4”(679)

24 3/4”(629)30”(762)

30 3/4”(781)32 3/4”(832)

30 3/4”(781)36”(914)

36 3/4”(933)38 3/4”(984)

34 3/4”(883)40”(1016)

40 3/4”(1035)42 3/4”(1086)

36 3/4”(933)42”(1067)

42 3/4”(1086)44 3/4”(1137)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

ELEVATION SYMBOL LEGEND:

##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.VALUES IN () ARE IN MILLIMETER CONVERSIONS.

##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.

Double-Hung Windows

W-2500

SCALE: 1/4” = 1’

Page 37: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-37

PICTURE UNITS

44”(1118)49 3/8”(1254)50 1/8”(1273)52 1/8”(1324)

42 3/4”(1086)48”(1219)

48 3/4”(1238)50 3/4”(1289)

48 3/4”(1238)54”(1372)

54 3/4”(1391)56 3/4”(1441)

54 3/4”(1391)60”(1524)

60 3/4”(1543)62 3/4”(1594)

25CDHP4812 25CDHP4912 25CDHP5412 25CDHP6012

25CDHP4818 25CDHP4918 25CDHP5418 25CDHP6018

25CDHP4824 25CDHP4924 25CDHP5424 25CDHP6024

25CDHP4830 25CDHP4930 25CDHP5430 25CDHP6030

25CDHP4836 25CDHP4936 25CDHP5436 25CDHP6036

25CDHP4840 25CDHP4940 25CDHP5440 25CDHP6040

25CDHP4842 25CDHP4942 25CDHP5442 25CDHP6042

25CDHP4848 25CDHP4948 25CDHP5448 25CDHP6048

35*50**

35*50**

35**50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

12”(

305)

123/

4”(3

24)

143/

4”(3

75)

71/

4”(1

84)

18”(

457)

183/

4”(4

76)

203/

4”(5

27)

131/

4”(3

37)

24”(

610)

243/

4”(6

29)

263/

4”(6

79)

191/

4”(4

89)

30”(

762)

303/

4”(7

81)

323/

4”(8

32)

251/

4”(6

41)

36”(

914)

363/

4”(9

33)

383/

4”(9

84)

311/

4”(7

94)

40”(

1016

)40

3/4”

(103

5)42

3/4”

(108

6)

351/

4”(8

95)

42”(

1067

)42

3/4”

(108

6)44

3/4”

(113

7)

371/

4”(9

46)

48”(

1219

)48

3/4”

(123

8)50

3/4”

(128

9)

431/

4”(1

099)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

ELEVATION SYMBOL LEGEND:

##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.VALUES IN () ARE IN MILLIMETER CONVERSIONS.

##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.

Double-Hung Windows

W-2500

SCALE: 1/4” = 1’

Page 38: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-38

PICTURE UNITS

25CDHP4854 25CDHP4954 25CDHP5454 25CDHP6054

25CDHP4856 25CDHP4956 25CDHP5456 25CDHP6056

25CDHP4860 25CDHP4960 25CDHP5460 25CDHP6060

25CDHP4864 25CDHP4964 25CDHP5464 25CDHP6064

25CDHP4868 25CDHP4968 25CDHP5468 25CDHP6068

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

54”(

1372

)54

3/4”

(139

1)56

3/4”

(144

1)

491/

4”(1

251)

56”(

1422

)56

3/4”

(144

1)58

3/4”

(149

2)

511/

4”(1

302)

60”(

1524

)62

3/4”

(159

4)64

3/4”

(164

5)

551/

4”(1

403)

64”(

1626

)64

3/4”

(164

5)66

3/4”

(169

5)

591/

4”(1

505)

68”(

1727

)68

3/4”

(174

6)70

3/4”

(179

7)

631/

4”(1

607)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

44”(1118)49 3/8”(1254)50 1/8”(1273)52 1/8”(1324)

42 3/4”(1086)48”(1219)

48 3/4”(1238)50 3/4”(1289)

48 3/4”(1238)54”(1372)

54 3/4”(1391)56 3/4”(1441)

54 3/4”(1391)60”(1524)

60 3/4”(1543)62 3/4”(1594)

ELEVATION SYMBOL LEGEND:

##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.VALUES IN () ARE IN MILLIMETER CONVERSIONS.

##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.

Double-Hung Windows

W-2500

SCALE: 1/4” = 1’

Page 39: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-39

PICTURE UNITS

25CDHP4872 25CDHP4972 25CDHP5472 25CDHP6072

25CDHP4876 25CDHP4976 25CDHP5476 25CDHP6076

25CDHP4888 25CDHP4988 25CDHP5488 25CDHP6088

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

72”(

1829

)72

3/4”

(184

8)74

3/4”

(189

9)

671/

4”(1

708)

76”(

1930

)76

3/4”

(194

9)78

3/4”

(200

0)

711/

4”(1

810)

88”(

2235

)88

3/4”

(225

4)90

3/4”

(230

5)

831/

4”(2

115)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

44”(1118)49 3/8”(1254)50 1/8”(1273)52 1/8”(1324)

42 3/4”(1086)48”(1219)

48 3/4”(1238)50 3/4”(1289)

48 3/4”(1238)54”(1372)

54 3/4”(1391)56 3/4”(1441)

54 3/4”(1391)60”(1524)

60 3/4”(1543)62 3/4”(1594)

ELEVATION SYMBOL LEGEND:

##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.VALUES IN () ARE IN MILLIMETER CONVERSIONS.

##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.

Double-Hung Windows

W-2500

SCALE: 1/4” = 1’

Page 40: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-40

PICTURE UNITS

56”(1422)61 3/8”(1559)62 1/8”(1578)64 1/8”(1629)

60 3/4”(1543)66”(1676)

66 3/4”(1695)68 3/4”(1746)

66 3/4”(1695)72”(1829)

72 3/4”(1848)74 3/4”(1899)

25CDHP6112 25CDHP6612 25CDHP7212

25CDHP6118 25CDHP6618 25CDHP7218

25CDHP6124 25CDHP6624 25CDHP7224

25CDHP6130 25CDHP6630 25CDHP7230

25CDHP6136 25CDHP6636 25CDHP7236

25CDHP6140 25CDHP6640 25CDHP7240

25CDHP6142 25CDHP6642 25CDHP7242

25CDHP6148 25CDHP6648 25CDHP7248

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

12”(

305)

123/

4”(3

24)

143/

4”(3

75)

71/

4”(1

84)

18”(

457)

183/

4”(4

76)

203/

4”(5

27)

131/

4”(3

37)

24”(

610)

243/

4”(6

29)

263/

4”(6

79)

191/

4”(4

89)

30”(

762)

303/

4”(7

81)

323/

4”(8

32)

251/

4”(6

41)

36”(

914)

363/

4”(9

33)

383/

4”(9

84)

311/

4”(7

94)

40”(

1016

)40

3/4”

(103

5)42

3/4”

(108

6)

351/

4”(8

95)

42”(

1067

)42

3/4”

(108

6)44

3/4”

(113

7)

371/

4”(9

46)

48”(

1219

)48

3/4”

(123

8)50

3/4”

(128

9)

431/

4”(1

099)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

ELEVATION SYMBOL LEGEND:

##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.VALUES IN () ARE IN MILLIMETER CONVERSIONS.

##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.

Double-Hung Windows

W-2500

SCALE: 1/4” = 1’

Page 41: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-41

PICTURE UNITS

25CDHP6154 25CDHP6654 25CDHP7254

25CDHP6156 25CDHP6656 25CDHP7256

25CDHP6160 25CDHP6660 25CDHP7260

25CDHP6164 25CDHP6664 25CDHP7264

25CDHP6168 25CDHP6668 25CDHP7268

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

54”(

1372

)54

3/4”

(139

1)56

3/4”

(144

1)

491/

4”(1

251)

56”(

1422

)56

3/4”

(144

1)58

3/4”

(149

2)

511/

4”(1

302)

60”(

1524

)62

3/4”

(159

4)64

3/4”

(164

5)

551/

4”(1

403)

64”(

1626

)64

3/4”

(164

5)66

3/4”

(169

5)

591/

4”(1

505)

68”(

1727

)68

3/4”

(174

6)70

3/4”

(179

7)

631/

4”(1

607)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

56”(1422)61 3/8”(1559)62 1/8”(1578)64 1/8”(1629)

60 3/4”(1543)66”(1676)

66 3/4”(1695)68 3/4”(1746)

66 3/4”(1695)72”(1829)

72 3/4”(1848)74 3/4”(1899)

ELEVATION SYMBOL LEGEND:

##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.VALUES IN () ARE IN MILLIMETER CONVERSIONS.

##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.

Double-Hung Windows

W-2500

SCALE: 1/4” = 1’

Page 42: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-42

PICTURE UNITS

25CDHP6172 25CDHP6672 25CDHP7272

25CDHP6176 25CDHP6676 25CDHP7276

25CDHP6188 25CDHP6688 25CDHP7288

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

72”(

1829

)72

3/4”

(184

8)74

3/4”

(189

9)

671/

4”(1

708)

76”(

1930

)76

3/4”

(194

9)78

3/4”

(200

0)

711/

4”(1

810)

88”(

2235

)88

3/4”

(225

4)90

3/4”

(230

5)

831/

4”(2

115)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

56”(1422)61 3/8”(1559)62 1/8”(1578)64 1/8”(1629)

60 3/4”(1543)66”(1676)

66 3/4”(1695)68 3/4”(1746)

66 3/4”(1695)72”(1829)

72 3/4”(1848)74 3/4”(1899)

ELEVATION SYMBOL LEGEND:

##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.VALUES IN () ARE IN MILLIMETER CONVERSIONS.

##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.

Double-Hung Windows

W-2500

SCALE: 1/4” = 1’

Page 43: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-43

ELEVATION DRAWINGS UTILIZE A LIMITED NUMBER OF PROJECTED LINES TO PRODUCE A RUDIMENTARY DRAWING INTENDEDTO BE USED IN A SMALL GRAPHICAL SCALE. ELEVATIONS ARE VIEWED PERPENDICULAR FROM THE EXTERIOR OF THESTRUCTURE. IF MORE DIMENSIONS ARE NEEDED, USE THE SECTION DRAWINGS FOR MORE COMPLETE DEPICTIONS.

1. ALL UNITS SHOWN ARE AVAILABLE AS STATIONARY ONLY.

2. UNIT ELEVATIONS ARE SHOWN WITHOUT EXTERIOR TRIM.

3. DIMENSIONAL VALUES IN BRACKETS ARE MILLIMETER CONVERSIONS.

4. UNIT SHOWN IS FOR A W-2500 DH TRANSOM WITH STANDARD SASH, THETRADITION SASH OPTION WILL HAVE A DIFFERENT DAYLIGHT OPENINGVALUE.

GENERAL DOUBLE HUNG TRANSOM NOTES

25CDHT2124

ROUGH OPENINGDIMENSIONS ARE

IN BOLD TEXT.

M.O. Adams/Flat CasingRough Opening

M.O. Brickmould

Frame Size

Masonry Openings for Brickmould, Flat & Adams Casing.Vertical measurements include sillnose.(Subtract 1/2” from Masonry Opening for Unit Size)

OUTSIDE OFFRAME.

’25CDHT’ INDICATESW2500 CLAD DOUBLE HUNG TRANSOM

BOOK CODE

THE LAST TWO NUMBERS INDICATETHE UNITS HEIGHTTHE FIRST TWO NUMBERS

INDICATE THE UNIT WIDTH

SEE SYMBOL LEGEND BELOW

ELEVATION SYMBOL LEGEND:

NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITHSTANDARD GLAZING.

##

DAYLIGHT OPENING

24 7/8” [ 632 ]27 7/8” [ 708 ]21 3/8” [ 543 ]15 1/16”(383)

27 1/16” [ 687 ]28 9/16” [ 725 ]24 3/4” [ 629 ]24” [ 610 ]19 1/8” [ 486 ]

##

ELEVATION NOTESTRANSOM UNITS

Double-Hung Windows

W-2500

Page 44: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-44

TRANSOM UNITS - 1 WIDE

ELEVATION SYMBOL LEGEND:

##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.VALUES IN () ARE IN MILLIMETER CONVERSIONS.

##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.

16”(406)21 3/8”(543)22 1/8”(562)24 1/8”(613)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

15”(

381)

153/

4”(4

00)

173/

4”(4

51)

103/

16”(

259)

20”(508)25 3/8”(645)26 1/8”(664)28 1/8”(714)

24”(610)29 3/8”(746)30 1/8”(765)32 1/8”(816)

28”(711)33 3/8”(848)34 1/8”(867)36 1/8”(918)

32”(813)37 3/8”(949)38 1/8”(968)

40 1/8”(1019)

36”(914)41 3/8”(1051)42 1/8”(1070)44 1/8”(1121)

24”(

610)

243/

4”(6

29)

263/

4”(6

80)

193/

16”(

487)

25CDHT2115 25CDHT2515 25CDHT2915 25CDHT3315 25CDHT3715 25CDHT4115

25CDHT412425CDHT372425CDHT332425CDHT292425CDHT252425CDHT2124

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

Double-Hung Windows

W-2500

SCALE: 1/4” = 1’

Page 45: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-45

TRANSOM UNITS - 1 WIDE - NOMINAL

N INDICATES NOMINALSIZING.

25CDHT2018N

13 15/16”(354)19 1/4”(489)

20”(508)22”(559)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

171/

4”(4

38)

18”(

457)

20”(

508)

127/

16”(

259)

17 15/16”(456)23 1/4”(591)

24”(610)26”(660)

21 15/16”(557)27 1/4”(692)

28”(711)30”(762)

25 15/16”(659)31 1/4”(794)

32”(813)34”(864)

29 15/16”(760)35 1/4”(895)

36”(914)38”(965)

25CDHT2418N 25CDHT2818N 25CDHT3218N 25CDHT3618N

35*50**

35*50**

35*50**

35*50**

35*50**

ELEVATION SYMBOL LEGEND:

##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.VALUES IN () ARE IN MILLIMETER CONVERSIONS.

##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.

Double-Hung Windows

W-2500

SCALE: 1/4” = 1’

Page 46: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-46

TRANSOM UNITS - 2 WIDE

20 1/16”(510)[2]50 3/4”(1365)51 1/2”(1308)53 1/2”(1359)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

24 1/16”(611)[2]58 3/4”(1492)59 1/2”(1511)61 1/2”(1562)

28 1/16”(713)[2]66 3/4”(1696)67 1/2”(1715)69 1/2”(1765)

32 1/16”(814)[2]74 3/4”(1899)75 1/2”(1918)77 1/2”(1969)

25CDHT2515-2 25CDHT2915-2 25CDHT3315-2

25CDHT3715-2

25CDHT3724-2

25CDHT3324-225CDHT2924-225CDHT2524-2

15”(

381)

153/

4”(4

00)

173/

4”(4

51)

103/

16”(

259)

24”(

610)

243/

4”(6

29)

263/

4”(6

80)

193/

16”(

487)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

15”(

381)

153/

4”(4

00)

173/

4”(4

51)

103/

16”(

259)

24”(

610)

243/

4”(6

29)

263/

4”(6

80)

193/

16”(

487)

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/4” = 1’

Page 47: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-47

TRANSOM UNITS - 3 WIDE

20 1/16”(510)[3]76 1/8”(1934)76 7/8”(1953)78 7/8”(2003)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

15”(

381)

153/

4”(4

00)

173/

4”(4

51)

103/

16”(

259)

24 1/16”(611)[3]88 1/8”(2238)88 7/8”(2257)90 7/8”(2308)

28 1/16”(713)[3]100 1/8”(2543)100 7/8”(2562)102 7/8”(2613)

32 1/16”(814)[3]112 1/8”(2848)112 7/8”(2867)114 7/8”(2918)

24”(

610)

243/

4”(6

29)

263/

4”(6

80)

193/

16”(

487)

25CDHT2515-3

25CDHT2524-3

25CDHT2915-3

25CDHT2924-3

25CDHT3315-3

25CDHT3324-3

25CDHT3715-3

25CDHT3724-3

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

15”(

381)

153/

4”(4

00)

173/

4”(4

51)

103/

16”(

259)

24”(

610)

243/

4”(6

29)

263/

4”(6

80)

193/

16”(

487)

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/4” = 1’

Page 48: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-48

TRANSOM UNITS - 4 WIDE

20 1/16”(510)[4]101 1/2”(2578)102 1/4”(2597)104 1/4”(2648)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

15”(

381)

153/

4”(4

00)

173/

4”(4

51)

103/

16”(

259)

25CDHT2515-4

24 1/16”(611)[4]117 1/2”(2985)118 1/4”(3004)120 1/4”(3054)

28 1/16”(713)[4]133 1/2”(3391)134 1/4”(3410)136 1/4”(3461)

32 1/16”(814)[4]149 1/2”(3797)150 1/4”(3816)152 1/4”(3867)

24”(

610)

243/

4”(6

29)

263/

4”(6

80)

193/

16”(

487)

25CDHT2524-4

25CDHT2915-4

25CDHT2924-4

25CDHT3315-4

25CDHT3324-4

25CDHT3715-4

25CDHT3724-4

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

15”(

381)

153/

4”(4

00)

173/

4”(4

51)

103/

16”(

259)

24”(

610)

243/

4”(6

29)

263/

4”(6

80)

193/

16”(

487)

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/4” = 1’

Page 49: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-49

TRANSOM UNITS - 5 WIDE

20 1/16”(510)[5]126 7/8”(3223)127 3/8”(3235)129 3/8”(3286)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

15”(

381)

153/

4”(4

00)

173/

4”(4

51)

103/

16”(

259)

25CDHT2515-5

24 1/16”(611)[5]146 7/8”(3731)147 3/8”(3743)149 3/8”(3794)

28 1/16”(713)[5]166 7/8”(4239)167 3/8”(4251)169 3/8”(4302)

32 1/16”(814)[5]186 7/8”(4747)187 3/8”(4759)189 3/8”(4810)

24”(

610)

243/

4”(6

29)

263/

4”(6

80)

193/

16”(

487)

25CDHT2524-5

25CDHT2915-5

25CDHT2924-5

25CDHT3315-5

25CDHT3324-5

25CDHT3715-5

25CDHT3724-5

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

15”(

381)

153/

4”(4

00)

173/

4”(4

51)

103/

16”(

259)

24”(

610)

243/

4”(6

29)

263/

4”(6

80)

193/

16”(

487)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGUNIT SIZE

15”(

381)

153/

4”(4

00)

173/

4”(4

51)

103/

16”(

259)

24”(

610)

243/

4”(6

29)

263/

4”(6

80)

193/

16”(

487)

ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.

Double-Hung Windows

W-2500

SCALE: 1/4” = 1’

Page 50: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-50

GLAZING OPTIONS

INTERIOR GLAZING OPTIONS

5/8”3/32”

SS//SS

DOUBLEHUNG

5/8”1/8”

DS//DS

DOUBLEHUNG

5/8”3/32”

CA URBAN FIRE CODE

DOUBLEHUNG

1/8”

W-2500

Double-Hung Windows

Page 51: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-51

JAMB EXTENDER OPTIONS

6 9/16” WALL9/16” JAMB THICKNESS

(OPTION)

9 5/16” WALLMAX 1-PC

JAMB EXTENDER

9/16” [14]

2” [51]

6 9/16” [167]

9/16” [14]

9 5/16” [237]

10 9/16” WALL

10 9/16” [268]

4 3/4” [121]

MAX WALL DEPTH

JAMB EXTENDER OPTIONS

W-2500

Double-Hung Windows

Page 52: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-52

STANDARD MULLION OPTIONS

TWIN OPERATING DOUBLE HUNGWITH 3/4” SOLID SPREAD MULL

2 1/8” [54]

6 3/32” [155]

3 1/4” [83]

OPERATING DOUBLE HUNGWITH DIRECT SET GEO

OPERATING DOUBLE HUNGWITH DIRECT SET RADIUS

1 1/4” [32]

3 3/4” [95]

2 25/32” [71]

1 1/4” [32]3 3/4” [95]

2 25/32” [71]

1 3/8”3 3/16” 1 3/8”3 3/16”

W-2500

Double-Hung Windows

Page 53: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-53

STANDARD MULLION OPTIONS

TWIN OPERATING DOUBLE HUNG

OPERATING DOUBLE-HUNG BESIDEIN-SASH PICTURE/TRANSOM BESIDE

7/8” [22]

4 13/16” [122]

3 3/8” [86]

OPERATING DOUBLE HUNGWITH IN-SASH PICTURE/TRANSOM

1 3/8” [35]

5 11/32” [136]

2 7/8” [73]

1 3/8” [35]

5 5/16” [135]

2 1/2” [64]

1 1/4” [32]

4 15/32” [114]

2 19/32” [66]

3 3/16”

1 3/8”

IN-SASH PICTURE/TRANSOM IN-SASH PICTURE/TRANSOM

W-2500

Double-Hung Windows

Page 54: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-54

LITE CUT INFORMATION

UNEVEN

GOTHIC

VERTICAL PRAIRIE

RADIUSDIAMOND

RECTANGULAR

BAR ALIGNMENT

Alignment of divided lite muntin bars from one window to the

next is often required by fine architectural design. Wood

grilles, GBG’s, and Simulated Divided Lites may be specified

with muntin bars aligned.

LITE CUT OPTIONS

Special lite cut patterns can include a wide

variety of straight line and radius patterns.

The illustrations shown here represent just a

few of the possibilities. Rectangular,

horizontal, vertical and Prairie lite patterns

are available in all standard size clad double

hung windows. Uneven, diamond, radius

and Gothic lite cuts are available, subject to

approval. Approvals are based on the ability

to fulfill the design requirement while

maintaining the construction integrity of the

finished product.

Clad double hung windows are available with removable grilles in 7/8” Full surround or beaded SDL only, 5/8” flator 23/32” contour grilles between the glass (GBG) and Simulated Divided Lites. Standard lite cuts are rectangular,.

W-2500

Double-Hung Windows

Page 55: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-55

DIVIDED LITE OPTIONS

NOTES:ALL GLASS AND AIRSPACE DIMENSIONS PER CURRENT CARDINAL GLASS SPECSLITES WITH SHAPES, ANGLES, OR RADII OUTSIDE THE LISEC BENDERCAPABILITIES FOR STAINLESS STEEL WARM EDGE SPACER WILL HAVEALUMINUM BOX SPACER WITH THE SAME AIRSPACE DIMENSION SHOWN HERE

5/8” GRILLE 23/32” GRILLE

0.625 0.709

0.156

7/8” SDL

0.625

0.2500 0.2500

5/8” GRILLE 23/32” GRILLE

0.187 0.217

7/8” SDL

0.187

0.2500 0.2500

0.150 0.156

0.625 0.709 0.625

W-2500

Double-Hung Windows

Page 56: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-56

DRIP CAP & NAILING FLANGE

STANDARD OFFERING

ROUGH OPENING IS ALWAYS 3/4” OVERROUGH OPENING:

FRAME SIZE OF THE WINDOW

EXTREME SIZE OF THE WINDOW

UNITS WITH NO TRIM AND SILL NOSE:

(DRIP CAP & NAILING FLANGE ARENOT ADDED TO ANY UNIT SIZING)

MASONRY OPENING IS ALWAYS 1/2” OVERTHE UNIT SIZE OF THE WINDOW

WITH OR WITHOUT TRIM

UNIT SIZE IS ALWAYS THE

UNIT SIZE = FRAME SIZE

MASONRY OPENING:

GENERAL NOTES:

FRAME TO TRIMDIMENSIONS

TYPICAL FOR HEAD & SIDES

NON-STANDARD UNIT SIZINGEXTERIOR TRIM MUST USE SILL NOSE

FRAME = UNIT SIZEUNIT SIZE

UN

ITSI

ZEFR

AM

E=

UN

ITSI

ZEHORIZONTAL

ROUGH OPENING

3/8” [10]3/8” [10]

3/4” [19]

VER

TIC

AL

RO

UG

HO

PEN

ING

&A

DA

MS

CA

SIN

GFR

AM

E+

41/

16”

[104

]

31/

2”FL

AT

CA

SIN

G

FRA

ME

+2

9/16

”[6

5]BR

ICK

MO

ULD

UN

ITSI

ZE

UN

ITSI

ZE

& ADAMS CASING3 1/2” FLAT CASING

UNIT SIZE

FRAME + 3” [76]

UNIT SIZEBRICKMOULD

FRAME + 6” [152]

1 1/2” [38]BRICKMOULD

3” [76]3” FLAT &ADAMS CASING

UNIT SIZING, ROUGH OPENINGS& MASONRY OPENINGS

W-2500

Double-Hung Windows

Page 57: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-57

REVERSE COTTAGE WINDOW

COTTAGE & REVERSE COTTAGEConsult the Design Data Tables for clear opening information. For dimensional units, contact Jeld-Wen - Bend Window Division, Technical ServicesDepartment for clear opening information.

DOUBLE HUNG WINDOW

COTTAGE WINDOW

CLEAR OPENING FORMULA

Frame Width - 3 3/8” = Clear Opening

DOUBLE HUNG

VERTICAL

HORIZONTAL

CLEAR OPENING

2 27/64” [62]

CLEAR OPENING

1 11/16” [43]1 11/16” [43]

CLEAR OPENING

1 11/16” [43]1 11/16” [43]

CLEAR OPENING

1 11/16” [43]1 11/16” [43]

2 27/64” [62]

CLEAR OPENING

2 27/64” [62]

CLEAR OPENING

(Frame Height / 2) - 3 15/16” = Clear Opening

CLEAR OPENING LAYOUTDP35 SILL

W-2500

Double-Hung Windows

Page 58: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-58

VERTICAL SECTION

Day

light

Ope

ning

Gla

ssSi

ze

Sash

Size

Fram

eSi

ze

Roug

hO

peni

ng

1/2”

1”

1 11/16”

3/4”1/2”

3/4”

Day

light

Ope

ning

Gla

ssSi

ze

Sash

Size

Scre

enSi

ze

Uni

tSi

ze

1 1/4”

5 13/16”

4 9/16”

1 1/4”

5 13/16”

4 9/16”2”

1/2”

3/4”

2 5/16”

1/2”13/16”

SINGLE UNITS

Double-Hung Windows

W-2500

SCALE: 6” = 1’

Page 59: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-59

HORIZONTAL SECTION

Daylight Opening

Glass Size

Sash Size

Frame Size

Rough Opening

3/8” 3/8”

1/2” 1/2”

3/4”

1 7/16”

3/4”

1 7/16”

1 1/4”

5 13/16”

4 9/16”

1 1/4”

5 13/16”

4 9/16”

Sash Size

Glass Size

Screen Size

Unit Size

3/4”

1/2”

2 5/16”

3/4”

2 5/16”

1/2”

SINGLE UNITS

Double-Hung Windows

W-2500

SCALE: 6” = 1’

Page 60: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-60

HORIZONTAL SECTION

Daylight Opening

Glass Size

Sash Size

Frame Size

Rough Opening

3/8” 3/8”

1/2” 1/2”

3/4”

1 7/16”

3/4”

1 7/16”

1 1/4”

5 13/16”

4 9/16”

1 1/4”

5 13/16”

4 9/16”

Sash Size

Glass Size

Screen Size

Unit Size

3/4”

3/8”

2 7/16”

3/4”

2 7/16”

3/8”

DOUBLE-HUNG UNITSWITH CONCEALED JAMB LINER

Double-Hung Windows

W-2500

SCALE: 6” = 1’

Page 61: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-61

VERTICAL SECTION

Day

light

Ope

ning

Gla

ssSi

ze

Sash

Size

Fram

eSi

ze

Roug

hO

peni

ng

1/2”

3/4”

1 5/8”

2 1/16”

1/2”

Day

light

Ope

ning

Gla

ssSi

ze

Sash

Size

Scre

enSi

ze

Uni

tSi

ze

1 1/4”

5 13/16”

4 9/16”

5 13/16”

4 9/16”

2”

1/2”

2 1/16”

1/2”

13/16”

3/4”2 5/16”

DOUBLE-HUNG UNITSWITH TRADITIONAL SASH PACK

Double-Hung Windows

W-2500

SCALE: 6” = 1’

Page 62: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-62

HORIZONTAL SECTION

Daylight Opening

Glass Size

Sash Size

Frame Size

Rough Opening

3/8” 3/8”

1/2” 1/2”

1 1/4”

1 7/16”

1 1/4”

1 7/16”

1 1/4”

5 13/16”

4 9/16”

1 1/4”

5 13/16”

4 9/16”

Daylight Opening

Sash Size

Glass Size

Screen Size

Unit Size

1/2” 1/2”

1 1/4”

1/2”

2 5/16”

1 1/4”

2 5/16”

1/2”

DOUBLE-HUNG UNITSWITH TRADITIONAL SASH PACK

Double-Hung Windows

W-2500

SCALE: 6” = 1’

Page 63: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-63

HORIZONTAL SECTION

1 3/8”

5 13/16”

2 1/2”

5 5/16”

DOUBLE-HUNG UNITS - MULLION

Double-Hung Windows

W-2500

SCALE: 6” = 1’

Page 64: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-64

VERTICAL SECTION

Day

light

Ope

ning

Gla

ssSi

ze

Sash

Size

Fram

eSi

ze

Roug

hO

peni

ng

3/4”1 1/4”

5 13/16”

4 9/16”

1 1/4”

5 13/16”

4 9/16”

Uni

tSi

ze

1/2”

3/4”

11/16”

1 11/16”

3/4”

1/2”

IN-SASH PICTURE/TRANSOM

Double-Hung Windows

W-2500

SCALE: 6” = 1’

Page 65: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-65

HORIZONTAL SECTION

Daylight Opening

Glass Size

Sash Size

Frame Size

Rough Opening

1/2”

1 7/16”

3/4”

1 7/16”

3/4”

1/2”

3/8” 3/8”

1 1/4”

5 13/16”

4 9/16”

1 1/4”

5 13/16”

4 9/16”

Unit Size

IN-SASH PICTURE/TRANSOM

Double-Hung Windows

W-2500

SCALE: 6” = 1’

Page 66: Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications

Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-66

HORIZONTAL SECTION

1 3/8”

5 13/16”

2 1/2”

5 5/16”

IN-SASH PICTURE/TRANSOMMULLION

Double-Hung Windows

W-2500

SCALE: 6” = 1’