16
Proj. Name: 2-Storey Resd'l. Bldg. General Description: Location: Lolita Village, Brgy. Caibaan, Tacloban Ci Terrace Beam (RCB2) 4.5 m Client: Pitao BL Designer: Pitao BL Date: Feb. 14, 2008 DOUBLE REINFORCED BEAM (WSD) AT MID SPAN POSITIVE MOMENT DESIGN DATA FOR CONCRETE BEAMS: 13.8 17.2 20.7 27.6 ITEM fc' = 2,000.00 2,500.00 3,000.00 4,000.00 fc = .45fc' 6.21 7.76 9.31 12.41 Es 200,000.00 200,000.00 200,000.00 ### 17,564.80 19,638.05 21,512.40 24,840.38 n = Es/Ec 11.00 10.00 9.00 8.00 k = n/(n+fs/fc) 0.1984 0.2195 0.2330 0.2647 j = 1 - k/3 0.93 0.93 0.92 0.91 Given: fc': 3,000.00 psi Span L: 4.5 meters fc = 1,350.00 psi Beam Section: 9.308 mpa b 250 mm fs 40,000.00 psi d 300 mm 275.80 mpa Slab Thickness: 0.12 meters Concrete Covering: Top = 25 Slab Width : 2 meters Bottom = 35 Wall Ht. : 2.6 meters Wall Thk.: 0.13 meters DEADLOAD: BEAM : 1.766 Kn / m SLAB : 5.674 Kn / m WALL : 7.958 Kn / m SIESMIC: 1.134 Kn / m LIVELOAD: 2.8 5.6 Kn / m TOTAL LOAD: W = 22.132 Kn / m TRY: No. of Bars Bar Diameter Unit Area Tension 2 16 mm 201.06 sq.mm. 1 16 mm 201.06 sq.mm. Compression 2 16 mm 201.06 sq.mm. 1 16 mm 201.06 sq.mm. va<v THEREFORE: PROVIDE WEB REINFORCEMENT ACI CODE: MAX. SPACING, Sm = 150 mm IF: S>Sm : USE ACI CODE: Sm = D/2 150.00 mm Ec = 4730√fc'

Double RC Beam (WSD)

Embed Size (px)

Citation preview

Page 1: Double RC Beam (WSD)

Proj. Name: 2-Storey Resd'l. Bldg. General Description:Location: Lolita Village, Brgy. Caibaan, Tacloban City Terrace Beam (RCB2) 4.5 m. spanClient: Pitao BLDesigner: Pitao BLDate: Feb. 14, 2008

DOUBLE REINFORCED BEAM (WSD)

AT MID SPAN POSITIVE MOMENTDESIGN DATA FOR CONCRETE BEAMS:

13.8 17.2 20.7 27.6 ITEM fc' = 2,000.00 2,500.00 3,000.00 4,000.00

fc = .45fc' 6.21 7.76 9.31 12.41 Es 200,000.00 200,000.00 200,000.00 200,000.00

17,564.80 19,638.05 21,512.40 24,840.38 n = Es/Ec 11.00 10.00 9.00 8.00

k = n/(n+fs/fc) 0.1984 0.2195 0.2330 0.2647 j = 1 - k/3 0.93 0.93 0.92 0.91

Given: fc': 3,000.00 psi Span L: 4.5 metersfc = 1,350.00 psi Beam Section:

9.308 mpa b 250 mm fs = 40,000.00 psi d 300 mm

275.80 mpa Slab Thickness: 0.12 metersConcrete Covering: Top = 25 Slab Width : 2 meters

Bottom = 35 Wall Ht. : 2.6 metersWall Thk.: 0.13 meters

DEADLOAD:BEAM : 1.766 Kn / mSLAB : 5.674 Kn / mWALL : 7.958 Kn / mSIESMIC: 1.134 Kn / m

LIVELOAD: 2.8 5.6 Kn / mTOTAL LOAD: W = 22.132 Kn / m

TRY:No. of Bars Bar Diameter Unit Area

Tension 2 16 mm 201.06 sq.mm.1 16 mm 201.06 sq.mm.

Compression 2 16 mm 201.06 sq.mm.1 16 mm 201.06 sq.mm.

va<v THEREFORE: PROVIDE WEB REINFORCEMENT

ACI CODE: MAX. SPACING, Sm = 150 mm

IF: S>Sm : USE ACI CODE: Sm = D/2 150.00 mm

Ec = 4730√fc'

Page 2: Double RC Beam (WSD)

Terrace Beam (RCB2) 4.5 m. span

2.00 pcs. 16 mm. dia. RC Bars 34.5 mpa 1.00 pcs. 16 mm. dia. RC Bars 5,000.00 psi 15.51 200,000.00 mpa 300 mm 10 mm. dia. Stirrups 27,772.39 mpa sp.@ 150 mm o.c. 7.00 0.2825 0.91 pcs. mm. dia. RC Bars

2.00 pcs. 16 mm. dia. RC Bars 1.00 pcs. 16 mm. dia. RC Bars

250 mm.

@ Mid-span

Total Area 402.12 603.19 OK, SAFE Kana BAY!!!! 201.06 402.12 603.19 UNSAFE, TRY AGAIN!!!! 201.06

Page 3: Double RC Beam (WSD)

mm. dia. RC Barsmm. dia. RC Bars

mm. dia. RC Barsmm. dia. RC Barsmm. dia. RC Bars

Page 4: Double RC Beam (WSD)

Proj. Name: 2-Storey Resd'l. Bldg. General Description:Location: Lolita Village, Brgy. Caibaan, Tacloban CityClient: Pitao BLDesigner: Pitao BLDate: Feb. 14, 2008

INVESTIGATION OF DOUBLE REINF. BEAM

AT MID SPAN POSITIVE MOMENTDESIGN DATA FOR CONCRETE BEAMS:

13.8 17.2 20.7 mpaITEM fc' = 2,000.00 2,500.00 3,000.00 psi

fc = .45fc' 6.21 7.76 9.31 Es 200,000.00 200,000.00 200,000.00 mpa

17,564.80 19,638.05 21,512.40 mpan = Es/Ec 11.00 10.00 9.00

k = n/(n+fs/fc) 0.1984 0.2195 0.2330 j = 1 - k/3 0.93 0.93 0.92

Given: fc': 3,000.00 psi Span L: 4.5 metersfc = 1,350.00 psi Beam Section:

9.308 mpa b 250 mm fs = 40,000.00 psi d 300 mm

275.80 mpa Slab Thickness: 0.12 metersConcrete Covering: Top = 25 Slab Width : 2 meters

Bottom = 35 Wall Ht. : 2.6 metersWall Thk.: 0.13 meters

DEADLOAD:BEAM : 1.766 Kn / mSLAB : 5.674 Kn / mWALL : 7.958 Kn / mSIESMIC: 1.134 Kn / m

LIVELOAD: 2.8 5.6 Kn / mTOTAL LOAD: W = 22.132 Kn / m

DESIGN MOMENT: Md = WL^2/14 32.012 Kn - m

TRIAL BARS:No. of Bars Diameter Area,mm^2

Tension 2 16 mm. As = 402.1248Tension 2 12 mm. As = 226.20

Compression 2 16 mm. As' = 402.12IF: Mc > Md : SAFE, KAAYO BAY !!!IF: Ms > Md: SAFE, G'YUD NA BAY !!!

Ec = 4730√fc'

F20
Buenaventura Pitao: Enter data on yellow colored cells
Page 5: Double RC Beam (WSD)

2 pcs. 16 mm. dia. RC Bars

300 mm

pcs. mm. dia. RC Bars 2.00 pcs. 16 mm. dia. RC Bars 2.00 pcs. 12 mm. dia. RC Bars

250 mm.

@ Mid-span

Page 6: Double RC Beam (WSD)

Proj. Name: General Description:Location:Client:Designer:Date:

DOUBLE REINFORCED BEAM (WSD)

AT CONTINUOUS END POSITIVE MOMENTDESIGN DATA FOR CONCRETE BEAMS:

13.79 17.2 20.7 MpaITEM fc' = 2,000.00 2,500.00 3,000.00 psi

fc = .45fc' 6.21 7.74 9.32 Es 200,000.00 200,000.00 200,000.00 mpa

17,564.80 19,616.67 21,520.20 mpan = Es/Ec 11.00 10.00 9.00

k = n/(n+fs/fc) 0.1984 0.2191 0.2331 j = 1 - k/3 0.93 0.93 0.92

Given: fc': 3,000.00 psi Span L: 4.5 metersfc = 1,350.00 psi Beam Section: 0 meters

9.308 mpa b 250 mm fs = 40,000.00 psi d 300 mm

275.80 mpa Slab Thickness: 0.12 metersConcrete Covering: Top = 25 Slab Width : 2 meters

Bottom = 35 Wall Ht. : 2.6 metersWall Thk.: 0.13 meters

DEADLOAD:BEAM : 1.766 Kn / mSLAB : 5.674 Kn / mWALL : 7.958 Kn / mSIESMIC: 1.134 Kn / m

LIVELOAD: 2.8 5.6 Kn / m

DESIGN MOMENT: Md = W((L1+L2)/2)^2/10 9.337 Kn - m

IF: M1 > Md: THEREFORE: ANALYZE SINGLE REINFORCE BEAMIF: fs' < fs USE: COMPUTED fs'

TRY:No. of Bars Bar Diameter Unit Area Total Area

Tension 2.00 16 mm 201.06 sq.mm. 1.00 12 mm 113.10 sq.mm.

Compression 2.00 16 mm 201.06 sq.mm. - 16 mm 201.06 sq.mm.

va<v THEREFORE: PROVIDE WEB REINFORCEMENT

Ec = 4730√fc'

Page 7: Double RC Beam (WSD)

ACI CODE: MAX. SPACING, Sm = 150 mm

IF: S>Sm : USE ACI CODE: Sm = D/2 150.00 mm

Page 8: Double RC Beam (WSD)

2.00 pcs. 16 mm. dia. RC Bars 1.00 pcs. 12 mm. dia. RC Bars

300 mm10 mm dia. Stirrups

sp.@ 150 mm o.c.

2.00 pcs. 16 mm. dia. RC Bars - pcs. 16 mm. dia. RC Bars

250 mm.

@ Continues Edge Support

Total Area 402.12 515.22 OK, SAFE Kana BAY!!!! 113.10 402.12 - 402.12 OK, SAFE Kana BAY!!!!

Page 9: Double RC Beam (WSD)

Proj. Name: General Description:Location:Client:Designer:Date:

INVESTIGATION OF DOUBLE REINF. BEAM

AT CONTINUOUS NEGATIVE MOMENTDESIGN DATA FOR CONCRETE BEAMS:

13.79 17.2 20.7 mpaITEM fc' = 2,000.00 2,500.00 3,000.00 psi

fc = .45fc' 6.21 7.74 9.32 Es 200,000.00 200,000.00 200,000.00 mpa

17,564.80 19,616.67 21,520.20 mpan = Es/Ec 11.00 10.00 9.00

k = n/(n+fs/fc) 0.1984 0.2191 0.2331 j = 1 - k/3 0.93 0.93 0.92

Given: fc': 3,000.00 psi Span L: 4.5 metersfc = 1,350.00 psi Beam Section: 0 meters

9.308 mpa b 250 mm fs = 40,000.00 psi d 300 mm

275.80 mpa Slab Thickness: 0.12 metersConcrete Covering: Top = 25 Slab Width : 2 meters

Bottom = 35 Wall Ht. : 2.6 metersWall Thk.: 0.13 meters

DEADLOAD:BEAM : 1.766 Kn / mSLAB : 5.674 Kn / mWALL : 7.958 Kn / mSIESMIC: 1.134 Kn / m

LIVELOAD: 2.8 5.6 Kn / mTOTAL LOAD: W = 22.132 Kn / m

DESIGN MOMENT: Md = W((L1+L2)/2)^2/10 9.337 Kn - m

TRIAL BARS:No. of Bars Diameter Area,mm^2

Tension 2 16 mm. As = 402.1248Tension 1 12 mm. As = 113.10

Compression 2 16 mm. As' = 402.12

IF: Mc > Md : SAFE, KAAYO BAY !!!IF: Ms > Md: SAFE, G'YUD NA BAY !!!

Ec = 4730√fc'

Page 10: Double RC Beam (WSD)

2.00 pcs. 16 mm. dia. RC Bars 1.00 pcs. 12 mm. dia. RC Bars

300 mm

2 pcs. 16 mm. dia. RC Bars

250 mm.

@ Continues Edge Support

Page 11: Double RC Beam (WSD)

Proj. Name: General Description:Location:Client:Designer:Date:

DOUBLE REINFORCED BEAM (WSD)

AT DISCONTINUOUS END POSITIVE MOMENTDESIGN DATA FOR CONCRETE BEAMS:

13.79 17.2 20.7 mpaITEM fc' = 2,000.00 2,500.00 3,000.00 psi

fc = .45fc' 6.21 7.74 9.32 Es 200,000.00 200,000.00 200,000.00 mpa

17,564.80 19,616.67 21,520.20 mpan = Es/Ec 11.00 10.00 9.00

k = n/(n+fs/fc) 0.1984 0.2191 0.2331 j = 1 - k/3 0.93 0.93 0.92

Given: fc': 3,000.00 psi Span L: 4.5 metersfc = 1,350.00 psi Beam Section:

9.308 mpa b 250 mm fs = 40,000.00 psi d 300 mm

275.80 mpa Slab Thickness: 0.12 metersConcrete Covering: Top = 25 Slab Width : 2 meters

Bottom = 35 Wall Ht. : 2.6 metersWall Thk.: 0.13 meters

DEADLOAD:BEAM : 1.766 Kn / m

1/2L SLAB : 2.837 Kn / mWALL : 7.958 Kn / mSIESMIC: 1.049 Kn / m

LIVELOAD: 2.8 5.6 Kn / mTOTAL LOAD: W = 19.210 Kn / m

DESIGN MOMENT: Md = WL^2/16 24.312 Kn - m

IF: M1 < Md: THEREFORE : PROVIDE COMPRESION BARSIF: fs' < fs USE: COMPUTED fs'

TRY:No. of Bars Bar Diameter Unit Area Total Area

Tension 2.00 16 mm 201.06 sq.mm. 1.00 12 mm 113.10 sq.mm.

Compression 2.00 16 mm 201.06 sq.mm.

va<v THEREFORE: PROVIDE WEB REINFORCEMENT

SPACING, S = 2Avfv/v'b 1,042.41 mm

ACI CODE: MAX. SPACING, Sm = 150 mm

Ec = 4730√fc'

Page 12: Double RC Beam (WSD)

IF: S>Sm : USE ACI CODE: Sm = D/2 150.00 mm

Page 13: Double RC Beam (WSD)

2.00 pcs. 16 mm. dia. RC Bars 1.00 pcs. 12 mm. dia. RC Bars

300 mm10 mm dia. Stirrups

sp.@ 150 mm o.c.

2.00 pcs. 16 mm. dia. RC Bars

250 mm.

@ Discontinues Edge Support

Total Area 402.12 515.22 OK, SAFE Kana BAY!!!! 113.10 402.12 OK, SAFE Kana BAY!!!!

Page 14: Double RC Beam (WSD)

Proj. Name: 2 storey Resd'l. bldg. General Description:Location: Lolita Village, Tac. City RC beam Terrace 4 m. spanClient: Pitao BLDesigner: Pitao BLDate:

INVESTIGATION OF DOUBLE REINF. BEAM

AT DISCONTINUOUS NEGATIVE MOMENTDESIGN DATA FOR CONCRETE BEAMS:

13.79 17.2 20.7 mpaITEM fc' = 2,000.00 2,500.00 3,000.00 psi

fc = .45fc' 6.21 7.74 9.32 Es 200,000.00 200,000.00 200,000.00 mpa

17,564.80 19,616.67 21,520.20 mpan = Es/Ec 11.00 10.00 9.00

k = n/(n+fs/fc) 0.1984 0.2191 0.2331 j = 1 - k/3 0.93 0.93 0.92

Given: fc': 3,000.00 psi Span L: 4.5 metersfc = 1,350.00 psi Beam Section:

9.308 mpa b 250 mm fs = 40,000.00 psi d 300 mm

275.80 mpa Slab Thickness: 0.12 metersConcrete Covering: Top = 25 Slab Width : 2 meters

Bottom = 35 Wall Ht. : 2.6 metersWall Thk.: 0.13 meters

DEADLOAD:BEAM : 1.766 Kn / m

1/2L SLAB : 2.837 Kn / mWALL : 7.958 Kn / mSIESMIC: 1.049 Kn / m

LIVELOAD: 2.8 5.6 Kn / mTOTAL LOAD: W = 19.210 Kn / m

DESIGN MOMENT: Md = WL^2/16 24.312 Kn - m

TRIAL BARS:No. of Bars Diameter Area,mm^2

Tension 2 16 mm. As = 402.1248Tension 1 12 mm. As = 113.10

Compression 2 16 mm. As' = 402.12

IF: Mc > Md : SAFE, KAAYO BAY !!!IF: Ms > Md: SAFE, G'YUD NA BAY !!!

Ec = 4730√fc'

Page 15: Double RC Beam (WSD)

2 pcs. 16 mm. dia. RC Bars1 pcs. 12 mm. dia. RC Bars

300 mm

2.00 pcs. 16 mm. dia. RC Bars

250 mm.

@ Discontinues Edge Support