RUGGED AND DURABLE
Protection against dust and water is stan-dard and ensures reliable operation in all environments. The optional rubber-boot gives additional protection for the Dräger X-am 3000 from bumps and hits.
EASY TO USE
A large display enables the easy identifi-cation of the measured values. The simple 3-button operation and an easy to use menu ensure intuitive operation. The visible menu makes selecting and performing other functions quick and simple. After switching on the Dräger X-am 3000, it performs a self-test.
INTELLIGENT SENSORS
The precalibrated electrochemical sensors, and the catalytic sensor are automatically recognized and provide precise and reliablemeasuring results. All DrägerSensors show a fast and accurate response to changing gas concentrations.
INTEGRATED HIGH-PERFORMANCE PUMP
An optional internal pump which can be used together with 20 m / 66 ft. tubing is ideal for confined space applications. A convenient pump adaptor makes is easy to switch between pump and diffusion mode.
DISTINCTIVE ALARMS
In addition to a very loud audible alarm and a visual alarm, a vibrating alarm is inte-grated in the instrument. The functionality and the battery status are monitored con- tinuously and will, if necessary, generate an alarm. TWA and STEL are also evaluated. Different alarm cadences indicate pre and main alarm conditions.
USEFUL SOFTWARE FUNCTIONS
A life signal assures full functionality of theinstrument without a visual check by the operator. Even if the peak value disappeared before it could get registered, the Dräger X-am 3000 can recall all maximum values. When using a defined gas mixture, the instrument can be calibrated by pressing a single button.
Designed for industrial use under harsh conditions: The robust 2 to 4 gas detector Dräger X-am 3000 continually monitors H2S, CO, O2 and combustible gases in the ambient air. The functional design and microprocessor-controlled digital technology of the device are precisely adjusted to the needs and requirements of personal gas warning.
Dräger X-am® 3000
ST-
2881
-200
3
Dräger X-am® 3000With optionally integrated pump for industrial use under harsh conditions.
ST-
4981
-200
5
ST-
2432
-200
3
DrägerSensorsFast, accurate and reliable
Large displayAll values and status informationat a glance
Alarm functionsAudible, visual and vibrating alarm
Robust enclosureCompact, rugged and waterproof
02 | DRÄGER X-AM® 3000
MEET INDIVIDUAL POWER
REQUIREMENTS
NiMH and alkaline batteries are available and can be interchanged. There are diffe-rent charging options, including a car charger, to meet your specific requirements.
DATALOGGER OPTION
Dräger X-am 3000 can be fitted with a data-logger which records gas concentrations and alarms up to 30,000 sets of values.
CALIBRATION EQUIPMENT
Easy to use, fast and professional in perfor-mance: from a bump test to the complete documentation, Dräger offers practice- oriented solutions which ensure safety for each application. The automatic test and calibration system Dräger E-Cal and Dräger Bump-Test-Station complement one another to minimize time and effort.
Dräger X-am® 3000Optional internal pump –ideal for confined space applications.
ST-
2923
-200
3
Dräger X-am® 3000All menu functions on one level.
ST-
2706
-200
3
Dräger E-Cal The workshop solution for fully automatic function tests and calibratios.
ST-
1012
-200
4
DRÄGER X-AM® 3000 | 03
ORDER INFORMATION
Description Order No.
Dräger X-am 3000 83 17 730Consisting of: basic instrument with Ex and O2 sensors, an integrated pump, pump- and calibration cradle.A functional instrument must include a power supply unit and as an optional addendum a third and fourth sensor or the data logger can be ordered.
Dräger X-am 3000 83 17 740Consisting of: basic instrument with Ex and O2 sensors and calibration cradle.A functional instrument must include a power supply unit and as an optional addendum a third and fourth sensor or the data logger can be ordered.
Data logger, installed optiob 83 17 717
DrägerSensors Measuring Range Resolution Response time(t50) Order Code
DrägerSensor CatEx 2 0 – 100% UEG 1% UEG 8 sec. is included
0 – 5 Vol.-% CH4 0,1 Vol.-%
DrägerSensor O2 0 – 25 Vol.-% 0,1 Vol.-% 10 sec. is included
DrägerSensor H2S 0 - 100 ppm 1 ppm 15 sec. 68 10 032
DrägerSensor CO 0 - 1000 ppm 1 ppm 20 sec. 68 10 030
Power supply units
NiMH power pack 83 17 709
Alkaline power pack (without alkaline batteries) 83 17 716
Charging accessories
Charging module with power supply EUR 83 17 763
Charging module with power supply UK 83 17 761
Charging module with power supply AUS 83 17 752
Charging module with power supply JAPAN 83 17 850
Car charging connection cabel 12V/24V 83 17 754
Pump accessories
Pump cradle 83 17 328
Calibration accessories
Calibration cradle 83 17 336
Dräger E-Cal module 83 17 719
Power supply for Dräger E-Cal module 83 16 990
Dräger Bump-Test-Station (without gas cylinder) 83 17 425
Dräger Bump-Test-Station complete with one test gas cylinder 58L
(gas and concentration variable) 83 19 071
Communication accessories
Dräger GasVision 83 14 034
Dräger CC-Vision 64 08 515
RS 232 cable 9-25 64 08 257
Other accessories
Nylon carrying case 83 17 720
Leather carrying case 83 17 726
Case (without content) 33 10 847
Rubber boot, black 83 17 727
TECHNICAL DATA
Size (h x w x d, approx.) 90 x 140 x 55 mm,
3.5‘‘ x 5.5‘‘ x 2.2‘‘
Weight (approx.) 550 g, 20 oz.
Ambient conditions Temperature - 20 to + 55 °C; - 5 to + 130 °F
short term - 40 to + 55 °C; - 40 to + 130 °F
Pressure 700 to 1300 hPa, 20.7 to 38.4 inch Hg
Humidity 10 to 95 %RH
Ingress protection IP 65
Alarms visual 360 °
audible > 90 dB bei 30 cm
vibration
Operating time Alkaline > 24 hours (diffusion mode)
> 12 hours (pump mode)
NiMH > 18 hours (diffusion mode)
> 12 hours (pump mode)
Charging time < 4 hours
Pump mode maximum length of tubing 20 m
Approvals UL Class I, Div 1, Group A, B, C, D; Temp Code T4
CSA Class I, Div 1, Group A, B, C, D; Temp Code T4
CE-mark electromagnetic compatibility (directive 2004/108/EC)
IECEx Ex ia d I/IIC T4; - 25 ≤ = Ta ≤ = + 55 °C (rechargeable)
- 25 ≤ = Ta ≤ = + 50 °C (alkaline)
90 4
4 77
0 |
10.
12-1
| M
arke
ting
Com
mun
icat
ions
| P
P |
PR
| L
E |
Pri
nted
in
Ger
man
y |
Chl
orin
e-fr
ee –
env
iron
men
tally
com
patib
le |
Sub
ject
to
mod
ifica
tions
| ©
201
2 D
räge
rwer
k A
G &
Co.
KG
aA
HEADQUARTERSDräger Safety AG & Co. KGaARevalstrasse 123560 Lübeck, Germany
www.draeger.com
SPAINDräger Safety Hispania S.A.Calle Xaudaró 528034 MadridTel +34 91 728 34 00Fax +34 91 729 48 99
UNITED KINGDOMDraeger Safety UK Ltd.Blyth Riverside Business ParkBlyth, Northumberland NE24 4RGTel +44 1670 352-891Fax +44 1670 356-266
USADraeger Safety, Inc.101 Technology DrivePittsburgh, PA 15275Tel +1 412 787 8383Fax +1 412 787 2207
FRANCEDräger Safety France SAS3c route de la Fédération, BP 8014167025 Strasbourg Cedex 1Tel +33 3 88 40 59 29Fax +33 3 88 40 76 67
ITALYDraeger Safety Italia S.p.AVia Longarone 3520080 Zibido San Giacomo (MI), ItalyTel +39 02 90 59 49 1Fax +39 02 90 00 36 86
MEXICODraeger Safety S.A. de C.V.Av. Peñuelas No. 5 Bodega No. 37Fraccionamiento Industrial San PedritoQuerétaro, Qro MéxicoTel +52 442 246-1113Fax +52 442 246-1114
NETHERLANDSDräger Safety Nederland B.V.Edisonstraat 532700 AH ZoetermeerTel +31 79 344 46 66Fax +31 79 344 47 90
REP. OF SOUTH AFRICADräger South Africa (Pty) Ltd.P.O.Box 68601Bryanston 2021Tel +27 11 465 99 59Fax +27 11 465 69 53
SINGAPOREDraeger Safety Asia Pte Ltd67 Ayer Rajah Crescent #06-03Singapore 139950Tel +65 68 72 92 88Fax +65 65 12 19 08
SUBSIDIARIES
AUSTRALIADraeger Safety Pacific Pty. Ltd.Axxess Corporate ParkUnit 99, 45 Gilby RoadMt. Waverley Vic 3149Tel +61 3 92 65 50 00Fax +61 3 92 65 50 95
CANADADraeger Safety Canada Ltd.7555 Danbro CrescentMississauga, Ontario L5N 6P9Tel +1 905 821 8988Fax +1 905 821 2565
P. R. CHINABeijing Fortune Draeger Safety Equipment Co., Ltd.A22 Yu An Rd, B Area, Tianzhu Airport Industrial Zone, Shunyi District, Beijing 101300Tel +86 10 80 49 80 00Fax +86 10 80 49 80 05