    s Speed and distance run indicated ona large illuminated LCD display

    s Compact display unit and transducer

    s High accuracy by utilizing the Dopplerprinciple, paired beam eliminatingeffect of pitching, and velocitycorrection for change of watertemperature

    s Easy speed correction at mile postrun

    s Speed output to ARPA, radar, ECDIS,AIS, VDR, GMDSS equipment, etc.

    s Complies with IMO standard A.824,IEC 61023 and other related standards

    R

    R

    Catalogue No. M-1520

    FURUNO ELECTRIC CO., LTD.The future today with FURUNO's electronics technology

    TRADE MARK REGISTEREDMARCA REGISTRADA

    9-52 Ashihara-cho, Nishinomiya City, Japan Telephone: +81 (0)798 65 2111Telefax: +81 (0)798 65 4200, 66-4622, 66-4623

    DOPPLER SPEED LOG

    Model DS-80

    Marine Speed and Distance Measuring Equipment (SDME)FURUNO DEEPSEA WORLD

    The DS-80 is an SDME (Speed and Distance Measuring Equipment)utilizing the Doppler Effect principle. It complies with the latest IMO,IEC and ISO standards as well as the rules of theclassification societies.

    Unlike an electromagnetic speed log orother type, this equipment does notrequire a sensor protruding throughthe ship hull; this greatly reducesthe routine maintenance. Anotherspecial feature is the capability tomeasure own ship speeds at

    dead slow movement with highaccuracy. The pair-beams at1 MHz sonic frequencyensures accuracy in roughweather.The primary function isavailable without any operatoraction; just keep the powerswitch on. The user-friendlymenu ensures easy adjustment ofall functions. Auxiliary functionssuch as resetting the Distance Runand speed offset are easy on the menu.

    Optional analogue and digital remote displaysare available to enhance the convenience ofnavigation. A new transducer was designed with the samedimensions as the existing DS-70 transducer. It may be fitted to the hulldirectly or with a gate valve.

    Back

    http://../02ECHO.pdf
  • 8/8/2019 ds80

    2/2

    1. Measuring System Paired-beam Doppler log, 1 MHz2. Display unit 4.5" (95 x 60 mm) Monochrome LCD

    120 x 64 pixelsCharacter size: 12 or 23 mm high selectable

    3. Speed RangeForward: 0 - 40 knots, 0.1 knot stepsAstern: 0 - 10 knots, 0.1 knot steps

    4. Distance Run 0-999,999.99 nm, resettable to any

    value.5. Accuracy Speed through-the-water (STW):1%, display resolution 0.1 ktDistance run: 1%, in steps of 0.1 nm

    6. Water Depth Deeper than 3 m7. Correction

    Sound velocity: Automatic correction for change ofwater temperature

    Mile post run: 10% on menu8. Test -10 and 40 knots9. Power Supply 115/230 VAC10. Interface IEC 61162-1

    Output: VBW, VLW

    ENVIRONMENT (IEC 60945 test method)Temperature -15 C to +55 C (Display unit)Waterproofing Display unit; IPX5 CFR-46 (USCG)

    EQUIPMENT LIST

    Standard1. Display Unit DS-800 1 unit2. Transducer unit DS-820 with 10/20/30 m cable 1 unit3. Transceiver unit DS-810 1 unit4. Distribution box DS-801 1 unit5. Terminal box DS-802 1 unitOption1. Digital indicator DS-830 1 unit2. Distance indicator DS-840 1 unit3. Transducer tank DS-850 1 unit4. Flush mount kit F type or S type 1 unit5. Gate valve DS-786, DS-782 1 unit6. Junction box CI-630 1 unit

    SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

    00123B Printed in Japan

    400

    15.8

    "

    350

    13.8

    "

    251.0

    "355 14.0"

    440 17.3"

    375

    14.8

    "

    370

    14.6

    "

    133 5.2"

    130 5.1"

    209 8.2"

    175 6.9"

    85 3.4"78 3.1"15 0.6"

    (140 5.5") (32 1.3")

    100

    3.9

    "

    125

    4.9

    "

    4- 6

    70 2.8"

    215 8.5"

    205 8.1"

    187 7.4"

    130

    5.1

    "

    150.8"

    120.5"max

    (50

    2.0

    ")

    70

    2.8

    "

    68 2.7"170.7" 61 2.4"

    4- 5.5

    Cutout for flush mount

    Cutout for flush mount

    92

    183 7.2"

    92

    63 2.5"

    4- 5.5

    3.6"

    3.6

    "

    4.4

    "

    167 6.6"

    112

    136

    5.4

    "

    Flush mount kit F-type

    Flush mount kit S-type

    DISPLAY UN IT DS-800 Weight 0.6 kg, 1.3 lb

    SPECIFICATION OF DS-80

    Optional

    ARPA/RADAR,ECDIS, AIS,VDR, GMDSS

    IEC 61162-1

    Junction box

    115/230 VAC

    Analog display

    Max 300 m

    Remote Distance IndicatorDS-840

    Remote Speed IndicatorDS-830

    Display UnitDS-800

    Transducer UnitDS-820

    Distribution boxDS-801

    Transceiver UnitDS-810

    TTYCYCS-3S*

    Terminal bo x

    DS-802

    Terminal boxDS-802

    Terminal b oxDS-802

    CI-630

    10/20/30m

    * To be arranged locally

    DISTRIBUTION BOX

    DS-801

    Weight 14 kg, 30.9 lb

    TRANSCEIVER UNIT

    DS-810

    Weight 8.0 kg, 17.6 lb

    315

    12.4

    "

    315 12.4"340 14.0"

    16.5

    0.7

    "

    348

    13.7

    "

    111 4.4"

    108 4.3"

    396

    15.6

    "

    DS-782DS-786

    Gate Valve

    FURUNO U.S.A., INC.Camas, Washington, U.S.A.Phone: +1 360-834-9300 Telefax: +1 360-834-9400

    FURUNO (UK) LIMITEDDenmead, Hampshire, U.K.Phone: +44 2392-230303 Telefax: +44 2392-230101

    FURUNO FRANCE S.A.Bordeaux-Mrignac, FrancePhone: +33 5 56 13 48 00 Telefax: +33 5 56 13 48 01

    FURUNO ESPANA S.A.Madrid, SpainPhone: +34 91-725-90-88 Telefax: +34 91-725-98-97

    FURUNO DANMARK ASHvidovre, DenmarkPhone: +45 36 77 45 00 Telefax: +45 36 77 45 01

    FURUNO NORGE A/Slesund, NorwayPhone: +47 70 102950 Telefax: +47 70 127021

    FURUNO SVERIGE ABVstra Frlunda, SwedenPhone: +46 31-7098940 Telefax: +46 31-497093

    FURUNO SUOMI OYHelsinki, FinlandPhone: +358 9 341 7570 Telefax: +358 9 341 75716

    200

    225

    210

    450

    17.7

    "

    450 17.7"

    20 0.8"

    175

    220

    8.7

    "

    330

    13.0

    "

    350 13.8"

    20 0.8"