DATASHEET Dual & Single Fiber CWDM OADM Data Center & Cloud Computing Infrastruture Solutions Data Center & Cloud Computing REV.1.0 2018

Dual & Single Fiber CWDM OADM | FS · Introduction CWDM OADM 01 FS.COM designs and offers all types of fiber optical transmission products to support Storage, Data and Telecom Networks

Embed Size (px)

Citation preview

Page 1: Dual & Single Fiber CWDM OADM | FS · Introduction CWDM OADM 01 FS.COM designs and offers all types of fiber optical transmission products to support Storage, Data and Telecom Networks

DATASHEETDual & Single Fiber CWDM OADMData Center & Cloud ComputingInfrastruture Solutions

Data Center & Cloud Computing

REV.1.0 2018

Page 2: Dual & Single Fiber CWDM OADM | FS · Introduction CWDM OADM 01 FS.COM designs and offers all types of fiber optical transmission products to support Storage, Data and Telecom Networks

Introduction

01CWDM OADM

FS.COM designs and offers all types of fiber optical transmission products to support Storage, Data and Telecom Networks. Our high-quality and cost-effective components allow customers to build the most cost-effective and reliable transmission networks.

If our products online can't meet your flexible requirements, FS.COM also supports different kinds of customizations, including:

Technical Specifications

1

General Specifications

Ⅰ No. of Channel: 1ch, 2ch, 4ch, etc. available

Line Type: Dual/Single FiberⅢ

Line & Client Port: LC/SC/FC/ST, UPC/APC polish

Special Service: Monitor/1310nm/1550nm port

Ⅱ Wavelengths: Any wavelength combination from 1270nm to 1610nm

Housing:FMU/FLG/FUD plug-in module1U 19" rack mountABS pigtailed module

Industrial Temperature for Outside-Plant Applications

Ⅳ Transmission Direction: East and West, East or West

Page 3: Dual & Single Fiber CWDM OADM | FS · Introduction CWDM OADM 01 FS.COM designs and offers all types of fiber optical transmission products to support Storage, Data and Telecom Networks

CWDM OADM

I. No. of Channel & Wavelengths

2

General Specifications

CWDM Wavelengths

Defined by the ITU-T G.694.2, CWDM covers the wavelengths from 1270nm to 1610nm within 20nm channel spacing.

Color Coding for CWDM

For CWDM systems an industry standard color coding scheme is used. Color coded ports is designed to match the latches of CWDM transceivers for simplifying the installation.

Water Peak

For G.652 and G.694.2 optical fiber, the water peak occurs at 1383 ± 3nm within the telecommunication spectrum 1260 – 1625nm. Attenuation at and near the water peak can exceed 2 dB/km, so it is common practice to avoid 1390nm and 1410nm channels.

ITU channel no.

Wavelength color color coding

45 1450nm yellow orange

47 1470nm gray

49 1490nm violet

51 1510nm blue

53 1530nm green

55 1550nm yellow

57 1570nm orange

59 1590nm red

61 1610nm brown

ITU channel no.

Wavelength color color coding

27 1270nm light purple

29 1290nm sky blue

31 1310nm yellow green

33 1330nm yellow ocher

35 1350nm pink

37 1370nm beige

39 1390nm white

41 1410nm silver

43 1430nm black

Page 4: Dual & Single Fiber CWDM OADM | FS · Introduction CWDM OADM 01 FS.COM designs and offers all types of fiber optical transmission products to support Storage, Data and Telecom Networks

CWDM OADM

II. Line Type

3

Dual Fiber Applications

Dual fiber CWDM OADM adds and drops optical signals of same wavelengths into two fibers, while letting the rest of the wavelengths bypass to the needed destination. The CWDM transceiver connected to CWDM OADM should have the same wavelength as the client port.

Take 1ch 1470-1490nm CWDM OADM as an example, the wavelength of the transceiver mainly based on the transmit wavelength of the client port on the CWDM OADM.

TX 1470nm

RX 1490nm

TX 1510nm

RX 1530nm

TX 1550nm

RX 1570nm

TX 1590nm

RX 1610nm

1470nm

1510nm

1550nm

1590nm

CWD

M M

UX &

DEM

UX

Site A

RX 1470nm

TX 1490nm

RX 1510nm

TX 1530nm

RX 1550nm

TX 1570nm

RX 1590nm

TX 1610nm

1490nm

1530nm

1570nm

1610nm

CWD

M M

UX &

DEM

UX

Site B

Single Fiber Applications

In single fiber applications, CWDM OADM adds and drops optical signals of different wavelengths into a fiber in the opposite direction. It utilizes a single fiber for both adding and droping, which reduces overall costs, and increases the capacity of the fiber.

1ch Single Fiber

Bidirectional

1470nm

1490nm

1490nm

1470nm

1490nm 1470nm

Site C

Page 5: Dual & Single Fiber CWDM OADM | FS · Introduction CWDM OADM 01 FS.COM designs and offers all types of fiber optical transmission products to support Storage, Data and Telecom Networks

CWDM OADM

II. Transmission Direction

3

For adding/dropping CWDM channels across sites, we categorize our CWDM OADM in two groups: single-sided (East or West) and dual-sided (East and West).

If CWDM OADM adds/drops the wavelengths in one side on fiber network, it is the East or West module; On contrary, it is the East and West module.

East or West

The single-sided OADM removes one channel from the network in one direction and sends it to a local interface. The remaining channels are passed straight through to other nodes along the network.

East and West

The dual-sided OADM removes one channel from the network in one direction and sends it to a local interface in one direction. It also allows a second local port to add the same channel back onto the network fiber in the opposite direction.

TX: 1470nm-1530nm 1490nm-1530nm RX: 1490nm-1530nm

RX: 1470nm-1530nm TX: 1490nm-1530nm

1490nm-1530nm

Add:1470nm

Drop:1470nm

TX: 1470nm-1530nm 1490nm-1530nm RX: 1470nm-1530nm

RX: 1470nm-1530nm TX: 1470nm-1530nm

1490nm-1530nm

Add:1470nm

Drop:1470nm

Add:1470nm

Drop:1470nm

Page 6: Dual & Single Fiber CWDM OADM | FS · Introduction CWDM OADM 01 FS.COM designs and offers all types of fiber optical transmission products to support Storage, Data and Telecom Networks

01CWDM OADM 4

1%

III. Special Service

Monitor Port

It is used to monitor or test the power signal, usually at a 1% ratio, 2%, 3%, 5%, etc, also available. By connecting with measurement or monitoring equipment, such as power meters, spectrum analyzer, or FMT AIU/OPD card, the signal can be inspected without interrupting the existing network.

1310nm and 1550nm Ports

The 1310nm and 1550nm are actually WDM wavelengths. Many optical transceivers, especially the CWDM and DWDM SFP/SFP+ transceiver, support long-haul transmission over these two wavelengths. By connecting with the same wavelength optical transceivers, these two ports can be used to add 1310nm or 1550nm wavelengths into existing WDM networks.

PS: If 1310nm port is added, the following CWDM wavelengths can't be added: 1270nm, 1290nm, 1310nm, 1330nm and 1350nm;If 1550nm port is added, the following CWDM wavelengths can't be added: 1510nm, 1530nm, 1550nm, 1570nm and 1590nm.

Expansion port for future capacity expansion

1310nm for 40G LR4/ER4, 100G CFP LR4

TX

RX

CWD

M M

ux &D

emux

Mux&

Demux

λ1

λn

1%RX

TX

CWD

M M

ux &D

emux

1310nm for 40G LR4/ER4, 100G CFP LR4

Expansion port for future capacity expansion

Mux&

Demux

λ1

λnCWDM OADM

Page 7: Dual & Single Fiber CWDM OADM | FS · Introduction CWDM OADM 01 FS.COM designs and offers all types of fiber optical transmission products to support Storage, Data and Telecom Networks

01CWDM OADM

IV. Housing & Enclosure

FMU Plug-in module

1U/2U 19'' Rack Mount ABS Pigtailed module

Specifications about ABS Pigtailed module:

5

Cable Diameter: 0.9mm/2.0mm/3.0mm Pigtail Length: 0.25~2m

Connector: With/Without connectors ABS Size: 141x 115x 18mm, 120x 80x 18mm, 100x 80x 10mm

FMU 2-slot 1U Rack

200.5mm

42.3mm

215mm

250mm

431.5mm

44mm

1 2

3 4

FS.COM provides 4 different package options for CWDM OADM, including FMU/FUD plug-in module, 1U 19" rack mount, and ABS pigtailed module, as well as the matched chassis. FLG plug-in module and FLG 3-slot 1U rack can also be provided. If you need, please e-mail to [email protected].

① ②

③ ④

FUD 4-slot 1U Rack

FUD Plug-in module

200mm

20.2mm

215mm

250mm

431.5mm

44mm

250mm

431.5mm

44mm

Page 8: Dual & Single Fiber CWDM OADM | FS · Introduction CWDM OADM 01 FS.COM designs and offers all types of fiber optical transmission products to support Storage, Data and Telecom Networks

01CWDM OADM

Industrial temperature -40 ~ 85 °C can meet the requirements of outside-plant applications. All CWDM Mux Demux devices can be customized as industrial temperature. Generally, operating temperature is -5°C~ +75°C , storage temperature is -40°C~+85°C.

6

If you need even more requirements, welcome to contact [email protected] or [email protected]. We will do our absolute best to optimize your total solution.

V. Industrial Temperature for Outside-Plant Applications

ID Description FS P/N

Customized CWDM OADM

#70425 Dual Fiber CWDM OADM COADM-DF

#70426 Single Fiber CWDM OADM COADM-SF

CWDM OADM

#50554 1 Channel 1470nm Dual Fiber CWDM OADM, East and West FMU-MCA0147

#50556 4 Channels 1470-1530nm Dual Fiber CWDM OADM, East and West FMU-MCA044753

#50572 1 Channel 1470-1490nm Single Fiber CWDM OADM, East and West FMU-MCAS014749

Product List

Technical Specifications

Page 9: Dual & Single Fiber CWDM OADM | FS · Introduction CWDM OADM 01 FS.COM designs and offers all types of fiber optical transmission products to support Storage, Data and Telecom Networks

01CWDM OADM 7

Related Products

Fiber Optic CablesOptic WDM Transceivers FMT Multiple-Services Transport Platform

CWDM-SFPCWDM-10G SFP+CWDM-XFP10G CWDM X210G CWDM XENPAK

MTP/MPO Fiber Cables Ultra HD Fiber CablesFiber Patch CablesRuggedized Fiber CablesPre-terminated MultifiberCables

FTTx Cables and AssemblesCables Management Fiber Testers & Tools

Cable Manager & Wire DuctCable Ties

Fiber Optic CleanerFiber Tester

Fiber Splitters Fiber Distribution TerminalFTTx Transmission

OEO (WDM Transponders)OLP/OBP (Optical Protection)VOA (Optic Attenuator)

Page 10: Dual & Single Fiber CWDM OADM | FS · Introduction CWDM OADM 01 FS.COM designs and offers all types of fiber optical transmission products to support Storage, Data and Telecom Networks

FS.COM business radiate worldwide, if you need more efficient solutions for

Data Center, Optical Transport Network, and Enterprise Network, please contact

us at [email protected]

For more information visit www.fs.com

All statements, technical information, and recommendations related to the products here are based upon information believed to be reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact FS for more information.

Copyright © 2009-2018 FS.COM All Rights Reserved.

FS.COM© DATA CENTER &

CLOUD COMPUTING