DuPont Protera PRODUCT SPECIFICATION SHEET
DuPont Protera is one of the lightest weight NFPA 70E Category 2 technologies on the market today, and can stand up to more washes than FR cotton nylon blends of similar weight. But you wont just be safer; youll also feel better wearing it. In fact, in a recent independent comfort study wearers judged DuPont Protera the clear winner in overall comfort compared to FR cotton nylon blend garments of similar weight.
Customer Service:Canada 1-800-387-9326Mexico (52) 55 57 22 1222United States 1-800-931-3456
www.personalprotection.dupont.com
Copyright 2009 DuPont. The DuPont Oval Logo, DuPont, The miracles of science, NOMEX, KEVLAR, and Protera are registered trademarks or trademarks of E. I. du Pont de Nemours and Company or its affiliates. All rights reserved.K-16450-1 (10/09) Printed in the U.S.A.
User InstructionsCAUTION: READ BEFORE USE
1. Flammable Contaminants will reduce the thermal protection of any flame resistant garment. For maximum protection: Wash your new garment before wearing and after each
subsequent wearing to thoroughly remove potentially flammable contaminants.
Wearing undergarments is recommended with all flame resistant garments.
It is the responsibility of the garment user to examine its condition before and after each use to be sure it is suitable for use.
2. Anti-static garments of DuPont Protera should be used in conjunction with proper grounding procedures for maximum protection against the threat of spark. Do not remove garments in a hazardous environment.
Typical Physical Properties
Weight ( 5%), (oz/sq yd) 6.5 7.5 8.0 (g/sq meter) 220 255 270
Weave 2 x 1 Twill 2 x 1 Twill 2 x 1 Twill
Standard Colors Medium Blue Khaki Dark Blue NavyConstruction (ends/inch x picks/inch) 77 x 47 76 x 63 77 x 70
Vertical Flammability ASTM D6413 Char Length (inches W x F) 3.5 x 2.9 3.7 x 3.3 3.1 x 3.1 After Flame (seconds W x F) 0 x 0 0 x 0 0 x 0
Thermal Protective Performance (cal/cm2) NFPA 2112 12 12 13
Flash Fire Exposure (Manikin Test) ASTM F1930 passing NFPA 2112 requirements (% body burn [2.0 cal/cm2 sec] at 3 seconds) Arc Thermal Performance ATPV (cal/cm2) ASTM F1959 8.5 9.5 12.3
Tensile Strength (lbf W x F) ASTM D5034 175 x 115 170 x 140 180 x 155
Elmendorf Tear (lbf W x F) ASTM D1424 13 x 12 12 x 10 9 x 7
Dimensional Stability (% at 5x) 140F, AATCC 135 2 x 1 2 x 1 2 x 1
Air Permeability (ft3/ft2/min) ASTM D737 68 23 16
Washing Colorfastness (rating*) AATCC 61 4 4 3
Wicking (inches at 15 min W x F) 5 5 4
Pilling Resistance (rating*) ASTM D3512, 60 min 3 3 4
Heat Resistance (500F, 5 min) NFPA 2112 no burning, melting, separation or ignition
Thermal Shrinkage Resistance (% [500F, 5 min] NFPA 2112) 3.5 x 2 3 x 0 3 x 2
*Ratings: 5 = Best, 3 = Acceptable, 1 = PoorProtera fabrics meet the requirements of ASTM - F 150633% NOMEX and KEVLAR; 65% Modacrylic; 2% Antistatic
Product safety information is available upon requestThis information corresponds to our current knowledge on the subject. It is offered solely to provide possible suggestions for your own experimentations. It is not intended, however, to substitute for any testing you may need to conduct to determine for yourself the suitability of our products for your particular purposes. This information may be subject to revision as new knowledge and experience becomes available. Since we cannot anticipate all variations in actual end-use conditions, DuPONT MAKES NO WARRANTIES AND ASSuMES NO LIABILITy IN CONNECTION WITh ANy uSE OF ThIS INFORMATION. Nothing in this publication is to be considered as a license to operate under or a recommendation to infringe any patent right.
GARmENT CARE
For correct fit, try garment on before washing or wearing. Wash new garments before and after each wearing. Wash garments of DuPont Protera separately from
other garments. Wash light and dark colors separately. Machine wash hot (max 140F/60C) heavy duty detergent Tumble dry low (max 160F/71C) Do not use chlorine bleach Do not line-dry or store in sunlight