14
DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, Spain [email protected] www.duranelectronica.com I-FIDEGAS2008-v02 FIDEGAS Gas detection systems Certificatdo nº FS82426

DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, Spain [email protected] I-FIDEGAS2008-v02 FIDEGAS Gas detection

Embed Size (px)

Citation preview

Page 1: DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, Spain marketing@duranelectronica.com  I-FIDEGAS2008-v02 FIDEGAS Gas detection

DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, [email protected] www.duranelectronica.com

I-FIDEGAS2008-v02

FIDEGASGas detection systems

Certificatdo nº FS82426

Page 2: DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, Spain marketing@duranelectronica.com  I-FIDEGAS2008-v02 FIDEGAS Gas detection

DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, [email protected] www.duranelectronica.com

I-FIDEGAS2008-v02

Control unit for the detection of toxic and explosive gases provided with standard 4-20mA input for 2, 4 & 8 detectors. Exclusively developed to be installed with FIDEGAS S/3 (EEx d II C T6) detectors.

Cover (keypad) in English & Spanish

FIDEGAS CA presentation

FIDEGAS CA is provided of:

•2 actuation levels: Prealarm and Alarm•Available outputs at 12V DC, 230V AC & D.C. •Alarm & cabling fault indicators•LEDs: prealarm, alarm, fault, 100% L.E.L., auxiliary battery •Events memory

ATEX certificate issued by Madariaga Official Laboratory LOM 03ATEX2095 when FIDEGAS S/3 detectors are connected.

Connection cable:Halogen free shield cable with 1mm2 section for a maximum length of 250 m. Control unit & detector EARTH connected

Page 3: DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, Spain marketing@duranelectronica.com  I-FIDEGAS2008-v02 FIDEGAS Gas detection

DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, [email protected] www.duranelectronica.com

I-FIDEGAS2008-v02

Hydrogen H2

Methane CH4

Ethane C2H6

Propane C3H8

Butane C4H10

Pentane C5H12

Hexane C6H14

Heptano C7H16

Octane C8H18

Cyclohexane C6H12

Ethylene C2H4

Cyclopropane C3H6

Toluene C6H5CH3

Ammonia NH3

Acetylene C2H2

Acetone (CH3)2CO

Ethyl Acetate CH3COOC2H5

Methanol CH3OH

Ethanol C2H5OH

Isopropanol C3H7OH

Dimethyl ether (CH3)2O

Diethyl ether (C2H5)2O

Carbon Monoxide CO

Hydrogen Sulfide SH2

Ammonia NH3

Sulfur Dioxide SO2

Chlorine Cl2

Nitrogen Monoxide NO

Nitrogen Dioxide NO2

Ethylene Oxide CH2CH2O

Carbon Dioxide CO2

Oxygen O2

FIDEGAS S/3-2 Explosives FIDEGAS S/3 T1 & T2 Toxics

available gasesFIDEGAS S/3. Exproof detectors

For other gases, consult

EEx d II C T6

Page 4: DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, Spain marketing@duranelectronica.com  I-FIDEGAS2008-v02 FIDEGAS Gas detection

DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, [email protected] www.duranelectronica.com

I-FIDEGAS2008-v02

2.- Get rid of the the outer cover and pull back the mesh (pic 2).

3.- Adjust the mesh to the inner part of the cable gland, helping yourself with a screwdriver (pic 3).

1.- Unscrew the cable gland. Pass the cable through the cable gland about 15 cm. (pic.1). Mark the cable and cut the outer cover.

pic 1

pic 2

pic 3

4.- Introduce the washer to adjust the mesh inside the cable gland (pic 4). Fix the security circlip and adjust it against the washer helping yourself with a screwdriver (pic 5).

5.- Connect the cables in the wire clamp (pic 6).

6.- Assemble and fix the cable clamp with the right wrench in the correct order as indicated in pic. 7, 8 and 9.

7.- Once you have tighten the cable gland, connect the wire clamp and close the cover. Do not forget the allen security screw

pic 4 pic 5

pic 6

pic 7pic 8 pic 9

connectionsFIDEGAS S/3. Exproof detectors

Page 5: DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, Spain marketing@duranelectronica.com  I-FIDEGAS2008-v02 FIDEGAS Gas detection

DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, [email protected] www.duranelectronica.com

I-FIDEGAS2008-v02

maintenance maintenance

Each filter/sensor has its own electronic circuitsDo not swap sensors or circuits.

Recalibrate FIDEGAS S/3 detector every 2 years during its working life (at manufacturer´s factory)

Check the correct functioning of the detector with testing gas every 6 months

1

2

1

FIDEGAS S/3. Exproof detectors

Page 6: DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, Spain marketing@duranelectronica.com  I-FIDEGAS2008-v02 FIDEGAS Gas detection

DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, [email protected] www.duranelectronica.com

I-FIDEGAS2008-v02

Each filter/sensor has its own electronic circuitDo not swap sensors or circuits.

Dissassemble and replacement of FIDEGAS S/3 detector

1. Release the cables from the connector marked with 1, 2, 3, & Earth connection.Releasing the self-blocking take out the whole set (cable + connector/s).

2. Release sensor´s connector.

3. Unscrew the filter/sensor.Do not twist the flat cable, neither hook it with other elements.

4. Electronic circuit can be dissassembled after releasing 2 subjection screws .

maintenance maintenance FIDEGAS S/3. Exproof detectors

Page 7: DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, Spain marketing@duranelectronica.com  I-FIDEGAS2008-v02 FIDEGAS Gas detection

DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, [email protected] www.duranelectronica.com

I-FIDEGAS2008-v02

FIDEGAS CAQuick installation guideQuick installation guide

Certificatdo nº FS82426

Page 8: DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, Spain marketing@duranelectronica.com  I-FIDEGAS2008-v02 FIDEGAS Gas detection

DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, [email protected] www.duranelectronica.com

I-FIDEGAS2008-v02

1. Mount on the wall the control unit (door to be opened from left to right).

2. Control unit´s bag includes the following replacements: 2 1A fuses Thermal retractable tube to isolate the detector-panel shield connection cable avoiding short-circuits

Conectors It allows the correct functioning of the panel when one or more are not connected (or if they has been disconnected for revisions).

Screw M-4.

Electronic circuit

3. Control unit – detector connection

Fuse 1A. Protect the detectors. All fault LEDs lightining up mean blowed fuse

Isolate the shield using the thermal retractable tube and connect it to EARTH in the proper connector.

Connect: control unit-detector

Place the connector in those non used connectors

FIDEGAS CAQuick installation guideQuick installation guide

Page 9: DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, Spain marketing@duranelectronica.com  I-FIDEGAS2008-v02 FIDEGAS Gas detection

DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, [email protected] www.duranelectronica.com

I-FIDEGAS2008-v02

FIDEGAS CA2. Conector 230V AC

PREALARM: This output its timed to activate the extraction during 2 minutes.IT SHOULD NOT ACTIVATE ALARMS

Between C & NO (ALARM)

Between C & NC (GAS CUT)

230V CA OutputsDo the connection between C & NC or C & NO, being sure that the devices connected (electrovalve, contactor, siren, etc.) work at 230V and total consumption does not exceed the B fuse value of 2A.

12V CC OutputsDo the connection between C & NC or C & NO, being sure that the devices connected (electrovalve, contactor, siren, etc.) work at 2V and total consumption does not exceed the C fuse value of 0,5A.

Example of 12V output connection to an electrovalve

FIDEGAS CA2. Conector 12V DC

Dry contact (close contact and no powered).

Between C & NC (ALARM)

Between C & NO (GAS CUT)

CONSIDERATIONS: When connecting 230V -or after a main fault- wait for 30 s before REARMING the system.Pay attention to the fuses capacity (mentioned in the manual)When all fault LEDs will be lightining up, check the state of the fuse ( D - E )

FIDEGAS CAQuick installation guideQuick installation guide

Page 10: DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, Spain marketing@duranelectronica.com  I-FIDEGAS2008-v02 FIDEGAS Gas detection

DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, [email protected] www.duranelectronica.com

I-FIDEGAS2008-v02

FIDEGAS S/3 DETECTORS testing:

FIDEGAS CA

1

2

3

Put the cap on the sensor head

Introduce cannula In the cap´s hole

Release gas for 2 s.to activate alarmWait 3 s before releasing more gas as required gas concentrationto activate the ALARM keeps 2 m in the mask aprox.

Quick installation guideQuick installation guide

Testing bottle concentration is not suitable for calibration neither precision test.

Ii is only recommended to check the detectors correct functioning.

Page 11: DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, Spain marketing@duranelectronica.com  I-FIDEGAS2008-v02 FIDEGAS Gas detection

DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, [email protected] www.duranelectronica.com

I-FIDEGAS2008-v02

Stand-alone detectors

Page 12: DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, Spain marketing@duranelectronica.com  I-FIDEGAS2008-v02 FIDEGAS Gas detection

DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, [email protected] www.duranelectronica.com

I-FIDEGAS2008-v02

Stand-alone EXPROOF detector for explosive gases (Natural gas-Methane-, Butane-Propane, Hydrogen) provided with a relay output for acting when gas presence reaches a level equal or higher than 20% Low Explosive Limit (L.E.L.).

Available at 12V or 24V.

Coverage area: 16 m2 aprox.

Type of sensor Catalityc (with synterized metal)

Alarm level 20% L.E.L.

Useful life 4 years

Coverage area 16 m2 aprox.

Protection grade I.P. 435

Code of explosive atmosphere EEx d II C T6

FIDEGAS C30 presentation

Page 13: DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, Spain marketing@duranelectronica.com  I-FIDEGAS2008-v02 FIDEGAS Gas detection

DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, [email protected] www.duranelectronica.com

I-FIDEGAS2008-v02

applications

Batteries roomsCellars Chemical industryChicken farms Nuclear industryRefrigeration

Fertiliser plantsFumigationGrain storageGreenhousesLaboratories

Paper millsWater treatmentSteel worksSwimming pools Food processing

Page 14: DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, Spain marketing@duranelectronica.com  I-FIDEGAS2008-v02 FIDEGAS Gas detection

DURAN ELECTRONICA. Tomás Bretón 50, 28045 Madrid, [email protected] www.duranelectronica.com

I-FIDEGAS2008-v02

Tomás Bretón, 5028045 MADRID, [email protected]

© 2008 DURAN ELECTRONICA S.L.

I-FIDEGAS2008-v02

Certificatdo nº FS82426