17

dwg status: PLANNING - Coventrydemocraticservices.coventry.gov.uk/documents/s36546/Application FU… · Perimeter retaining wall Retaining/boundary walling in brick to match proposed

  • Upload
    lammien

  • View
    227

  • Download
    11

Embed Size (px)

Citation preview

Page 1: dwg status: PLANNING - Coventrydemocraticservices.coventry.gov.uk/documents/s36546/Application FU… · Perimeter retaining wall Retaining/boundary walling in brick to match proposed
Page 2: dwg status: PLANNING - Coventrydemocraticservices.coventry.gov.uk/documents/s36546/Application FU… · Perimeter retaining wall Retaining/boundary walling in brick to match proposed

St Columa's Close

St Nicholas Street

dwg title:

job title:

scale:date:

dwg no:

drawn:job no:

rev:

oconnell east architects63 Newton Street, Manchester, M1 1ETt: 0161 839 9380 f: 0161 833 1638

oea

dwg status:

O'Connell East Architects - 2016

oeaAll dimensions are in millimetres unless stated otherwise. No dimensions to be scaled from drawings. All dimensions to be checked on site prior to manufacture.

Any discrepancies between drawings and site conditions are to be reported to the contract manager.

This drawing is to be read in conjunction with all relevant Structural Engineers and Mechanical & Electrical Engineers drawings and specification.

Copyright of this drawing and all the information it contains is the sole property of OEA and may not be reproduced or used for any purpose without the express approval of the authors

Notes:

CNM Capital Ltd.

1 : 1250

Site Location Plan

Combined Sites St Columbas Close

JG

1675

1675_PL_001

04/09/2017

Rev Description Date By Chk

1 : 1250Location Plan1

PLANNING

Page 3: dwg status: PLANNING - Coventrydemocraticservices.coventry.gov.uk/documents/s36546/Application FU… · Perimeter retaining wall Retaining/boundary walling in brick to match proposed

St Columbas Close

St Nicholas Street

dwg title:

job title:

scale:date:

dwg no:

drawn:job no:

rev:

oconnell east architects63 Newton Street, Manchester, M1 1ETt: 0161 839 9380 f: 0161 833 1638

oea

dwg status:

O'Connell East Architects - 2016

oeaAll dimensions are in millimetres unless stated otherwise. No dimensions to be scaled from drawings. All dimensions to be checked on site prior to manufacture.

Any discrepancies between drawings and site conditions are to be reported to the contract manager.

This drawing is to be read in conjunction with all relevant Structural Engineers and Mechanical & Electrical Engineers drawings and specification.

Copyright of this drawing and all the information it contains is the sole property of OEA and may not be reproduced or used for any purpose without the express approval of the authors

Notes:

CNM Capital Ltd.

1 : 500

Site Plan

Combined Sites St Columbas Close

JG

1675

1675_PL_002

04/09/17

1 : 500Site Plan1

PLANNING

Rev Description Date By Chk

Page 4: dwg status: PLANNING - Coventrydemocraticservices.coventry.gov.uk/documents/s36546/Application FU… · Perimeter retaining wall Retaining/boundary walling in brick to match proposed

94.00

94.0

0

95.0

0

95.0095.00

96.00

96.0

0

96.0

0

97.00

97.00

95.00

94.00

95.00

95.00

94.00

94.00

UP

UP

22 m²Cinema

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

45 m²Twodio

45 m²Twodio

46 m²Common Room

46 m²Cycle Store

23 m²Plant

sub-stationover

92195

dwg title:

job title:

scale:

date:

dwg no:

drawn:

job no:

rev:

oconnell east architects63 Newton Street, Manchester, M1 1ETt: 0161 839 9380 f: 0161 833 1638

oea

oea

All dimensions are in millimetres unless stated otherwise. No dimensions to be scaled from drawings. All dimensions to be checked on site prior to manufacture.

Any discrepancies between drawings and site conditions are to be reported to the contract manager.

This drawing is to be read in conjunction with all relevant Structural Engineers and Mechanical & Electrical Engineers drawings and specification.

Copyright of this drawing and all the information it contains is the sole property of OEA and may not be reproduced or used for any purpose without the express approval of the authors

Notes:

@ A1

dwg status:

C OConnell East Architects - 2015

CNM Capital

1 : 100

B

Lower Ground Floor

Combined Sites St ColumbasClose

JG1675

1675_PL_101

04/09/17 1 : 100Level -11

Rev Description Date By Chk

A Amended to suit phasing 15.08.17B Low wall added to rear boundary 14.09.17

PLANNING

Page 5: dwg status: PLANNING - Coventrydemocraticservices.coventry.gov.uk/documents/s36546/Application FU… · Perimeter retaining wall Retaining/boundary walling in brick to match proposed

+ 95880

+ 95280

+ 95120

+ 94190

Low hedge planted intowidened boundary wall withplanting cavity.

Low hedge planted intowidened boundary wall withplanting cavity.

+95.195

+94.595

FFL

94.695

FFL

95.295

FFL

95.295

FFL

95.295

FFL

95.295

DN

DN

DN

DN

S

t

.

C

o

l

u

m

b

a

'

s

C

l

o

s

e

22 m²

Studio

22 m²

Studio

22 m²

Studio

22 m²

Studio

22 m²

Studio

45 m²

Twodio

45 m²

Twodio

22 m²

Studio

22 m²

Studio

22 m²

Studio

22 m²

Studio

16 m²

Substation

5 m²

Comms

6 m²

Switches

23 m²

Refuse Store

11 m²

Management

Office

1

1

0

0

void

Ornamental Shrub PlantingProposed shrubs and flowering herbaceousplants to be planted as 3-5L pots at 3-5 per sq.m.with feature specimen 10-12L.

Proposed Ornamental HedgeProposed ornamental hedge to be planted intoperimeter wall

LEGEND - SOFT LANDSCAPE

LEGEND - HARD LANDSCAPE

Block Paving - Type 1To be block paving 350 x 110 x 80mm, in greyor silver grey blend. Kellen by hardscape orsimilar approved

Kerb EdgingCountry Edge kerb 75 x 150 x 900mm ingranite aggregate finish,laid with 50mm upstand to paving

Existing Trees to be Retained

Perimeter WallingAs architects details 1.2m

Perimeter retaining wallRetaining/boundary walling in brick to matchproposed building or other materials as agreed.Retaining soil as required around -1 lowerground levels

Perimeter walling with hedgeAs architects details. Solid wall to 1.2m highwith cavity wall min 300mm wide to take lowhedge planting above.

External StepsTo architects details

Scale @ A1

Status

Description

Drawing number

Drawn

Revision

Checked

Client

Project

2730

1:100

for planning

103

ct

B

ct

Landscape Layout levels -1-0

St Columbus

CNM Capital Ltd

address: 4th Floor Studio 10 Little Lever St Manchester M1 1HRtel: 0161 235 0600 fax 0601 email [email protected]

chartered landscape architects

Date

00.00.15

Rev

A CT 08.03.17Building layout amended

By Description Date

Job number

N

GENERAL NOTES

1. This drawing is the copyright of tpm landscape Ltd andcannot be reproduced in any form without the consentof the company.

2. This drawing is to be read in conjunction with detaillandscape drawings, details and specification.

3. This drawing is to be read in conjunction with allrelevant Architects', Engineer's, Specialists, Bills ofQuantities and Specifications.

4. The insertion of any firm or proprietary brand on thisdrawing is an indication of the class or quality requiredand does not exclude the use of alternative materialsthat are equal in performance, quality and appearance,provided that they have been approved in writing bythe Landscape Architect.

5. The Contractor is responsible for accuratelyascertaining the position of underground services andresponding to all relevant service easementrequirements.

6. All dimensions are in millimetres unless statedotherwise, for the purposes of construction thisdrawing must not be scaled and only writtendimensions used. Written and scaled dimensions to bechecked on site, any discrepancies reported prior towork commencing. IF IN DOUBT PLEASE ASK.

7. All work and materials are to be in accordance with therelevant British Standards and Code of Practice.

8. All Proprietary products are to be used strictly inaccordance with the manufacturer's instructions anddetails.

REVISION NOTES

LEGEND

B EG 29.09.17Building layout amended

Page 6: dwg status: PLANNING - Coventrydemocraticservices.coventry.gov.uk/documents/s36546/Application FU… · Perimeter retaining wall Retaining/boundary walling in brick to match proposed

e

ng

DNDN

DNDN

St. Columba's Close

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

45 m²Twodio

45 m²Twodio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

95295

16 m²Substation

5 m²Comms

6 m²Switches

23 m²Refuse Store

11 m²

ManagementOffice

95295

95295

95295

94695

94595

95195

95295 95045

1100

void

dwg title:

job title:

scale:

date:

dwg no:

drawn:

job no:

rev:

oconnell east architects63 Newton Street, Manchester, M1 1ETt: 0161 839 9380 f: 0161 833 1638

oea

oea

All dimensions are in millimetres unless stated otherwise. No dimensions to be scaled from drawings. All dimensions to be checked on site prior to manufacture.

Any discrepancies between drawings and site conditions are to be reported to the contract manager.

This drawing is to be read in conjunction with all relevant Structural Engineers and Mechanical & Electrical Engineers drawings and specification.

Copyright of this drawing and all the information it contains is the sole property of OEA and may not be reproduced or used for any purpose without the express approval of the authors

Notes:

@ A1

dwg status:

C OConnell East Architects - 2015

CNM Capital

1 : 100

B

Ground Floor

Combined Sites St ColumbasClose

JG1675

1675_PL_102

04/09/17 1 : 100Level 01

Rev Description Date By Chk

A Amended to suit phasing 15.08.17B Low wall added to rear boundary 14.09.17

PLANNING

Page 7: dwg status: PLANNING - Coventrydemocraticservices.coventry.gov.uk/documents/s36546/Application FU… · Perimeter retaining wall Retaining/boundary walling in brick to match proposed

e

g

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

dwg title:

job title:

scale:

date:

dwg no:

drawn:

job no:

rev:

oconnell east architects63 Newton Street, Manchester, M1 1ETt: 0161 839 9380 f: 0161 833 1638

oea

oea

All dimensions are in millimetres unless stated otherwise. No dimensions to be scaled from drawings. All dimensions to be checked on site prior to manufacture.

Any discrepancies between drawings and site conditions are to be reported to the contract manager.

This drawing is to be read in conjunction with all relevant Structural Engineers and Mechanical & Electrical Engineers drawings and specification.

Copyright of this drawing and all the information it contains is the sole property of OEA and may not be reproduced or used for any purpose without the express approval of the authors

Notes:

@ A1

dwg status:

C OConnell East Architects - 2015

CNM Capital

1 : 100

B

2nd Floor

Combined Sites St ColumbasClose

JG1675

1675_PL_104

04/09/17

1 : 100Level 21

Rev Description Date By Chk

A Amended to suit phasing 15.08.17B Low wall added to rear boundary 14.09.17

PLANNING

Page 8: dwg status: PLANNING - Coventrydemocraticservices.coventry.gov.uk/documents/s36546/Application FU… · Perimeter retaining wall Retaining/boundary walling in brick to match proposed

e

g

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

46 m²Twodio

22 m²Studio

22 m²Studio

dwg title:

job title:

scale:

date:

dwg no:

drawn:

job no:

rev:

oconnell east architects63 Newton Street, Manchester, M1 1ETt: 0161 839 9380 f: 0161 833 1638

oea

oea

All dimensions are in millimetres unless stated otherwise. No dimensions to be scaled from drawings. All dimensions to be checked on site prior to manufacture.

Any discrepancies between drawings and site conditions are to be reported to the contract manager.

This drawing is to be read in conjunction with all relevant Structural Engineers and Mechanical & Electrical Engineers drawings and specification.

Copyright of this drawing and all the information it contains is the sole property of OEA and may not be reproduced or used for any purpose without the express approval of the authors

Notes:

@ A1

dwg status:

C OConnell East Architects - 2015

CNM Capital

1 : 100

B

1st Floor

Combined Sites St ColumbasClose

JG1675

1675_PL_103

04/09/17 1 : 100Level 11

Rev Description Date By Chk

A Amended to suit phasing 15.08.17B Low wall added to rear boundary 14.09.17

PLANNING

Page 9: dwg status: PLANNING - Coventrydemocraticservices.coventry.gov.uk/documents/s36546/Application FU… · Perimeter retaining wall Retaining/boundary walling in brick to match proposed

re

ng

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

30 m²Accessible Studio

22 m²Studio

25 m²Common Room

22 m²Studio

22 m²Studio

22 m²Studio

dwg title:

job title:

scale:

date:

dwg no:

drawn:

job no:

rev:

oconnell east architects63 Newton Street, Manchester, M1 1ETt: 0161 839 9380 f: 0161 833 1638

oea

oea

All dimensions are in millimetres unless stated otherwise. No dimensions to be scaled from drawings. All dimensions to be checked on site prior to manufacture.

Any discrepancies between drawings and site conditions are to be reported to the contract manager.

This drawing is to be read in conjunction with all relevant Structural Engineers and Mechanical & Electrical Engineers drawings and specification.

Copyright of this drawing and all the information it contains is the sole property of OEA and may not be reproduced or used for any purpose without the express approval of the authors

Notes:

@ A1

dwg status:

C OConnell East Architects - 2015

CNM Capital

1 : 100

B

3rd Floor

Combined Sites St ColumbasClose

JG1675

1675_PL_105

04/09/17

1 : 100Level 31

Rev Description Date By Chk

A Amended to suit phasing 15.08.17B Low wall added to rear boundary 14.09.17

PLANNING

Page 10: dwg status: PLANNING - Coventrydemocraticservices.coventry.gov.uk/documents/s36546/Application FU… · Perimeter retaining wall Retaining/boundary walling in brick to match proposed

e

ng

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

22 m²Studio

21 m²Studio

22 m²Studio

28 m²Studio

27 m²Studio

25 m²Studio

24 m²Studio

25 m²Studio

dwg title:

job title:

scale:

date:

dwg no:

drawn:

job no:

rev:

oconnell east architects63 Newton Street, Manchester, M1 1ETt: 0161 839 9380 f: 0161 833 1638

oea

oea

All dimensions are in millimetres unless stated otherwise. No dimensions to be scaled from drawings. All dimensions to be checked on site prior to manufacture.

Any discrepancies between drawings and site conditions are to be reported to the contract manager.

This drawing is to be read in conjunction with all relevant Structural Engineers and Mechanical & Electrical Engineers drawings and specification.

Copyright of this drawing and all the information it contains is the sole property of OEA and may not be reproduced or used for any purpose without the express approval of the authors

Notes:

@ A1

dwg status:

C OConnell East Architects - 2015

CNM Capital

1 : 100

B

4th Floor

Combined Sites St ColumbasClose

JG1675

1675_PL_106

04/09/17

1 : 100Level 41

Rev Description Date By Chk

A Amended to suit phasing 15.08.17B Low wall added to rear boundary 14.09.17

PLANNING

Page 11: dwg status: PLANNING - Coventrydemocraticservices.coventry.gov.uk/documents/s36546/Application FU… · Perimeter retaining wall Retaining/boundary walling in brick to match proposed

e

ng

14 m²Studio_Mezz

8 m²Studio_Mezz

dwg title:

job title:

scale:

date:

dwg no:

drawn:

job no:

rev:

oconnell east architects63 Newton Street, Manchester, M1 1ETt: 0161 839 9380 f: 0161 833 1638

oea

oea

All dimensions are in millimetres unless stated otherwise. No dimensions to be scaled from drawings. All dimensions to be checked on site prior to manufacture.

Any discrepancies between drawings and site conditions are to be reported to the contract manager.

This drawing is to be read in conjunction with all relevant Structural Engineers and Mechanical & Electrical Engineers drawings and specification.

Copyright of this drawing and all the information it contains is the sole property of OEA and may not be reproduced or used for any purpose without the express approval of the authors

Notes:

@ A1

dwg status:

C OConnell East Architects - 2015

CNM Capital

1 : 100

4th Floor Mezzanine

Combined Sites St ColumbasClose

Author1675

1675_PL_107

09/14/17

Rev Description Date By Chk

1 : 100Level 4-Mezz1

Page 12: dwg status: PLANNING - Coventrydemocraticservices.coventry.gov.uk/documents/s36546/Application FU… · Perimeter retaining wall Retaining/boundary walling in brick to match proposed

re

ng

21 m²Studio

21 m²Studio

25 m²Studio

27 m²Studio

Mezz.

Mezz.

28 m²Studio

dwg title:

job title:

scale:

date:

dwg no:

drawn:

job no:

rev:

oconnell east architects63 Newton Street, Manchester, M1 1ETt: 0161 839 9380 f: 0161 833 1638

oea

oea

All dimensions are in millimetres unless stated otherwise. No dimensions to be scaled from drawings. All dimensions to be checked on site prior to manufacture.

Any discrepancies between drawings and site conditions are to be reported to the contract manager.

This drawing is to be read in conjunction with all relevant Structural Engineers and Mechanical & Electrical Engineers drawings and specification.

Copyright of this drawing and all the information it contains is the sole property of OEA and may not be reproduced or used for any purpose without the express approval of the authors

Notes:

@ A1

dwg status:

C OConnell East Architects - 2015

CNM Capital

1 : 100

B

5th Floor

Combined Sites St ColumbasClose

JG1675

1675_PL_108

03/01/2017

1 : 100Level 51

PLANNING

Rev Description Date By Chk

A Amended to suit phasing 15.08.17B Low wall added to rear boundary 14.09.17

Page 13: dwg status: PLANNING - Coventrydemocraticservices.coventry.gov.uk/documents/s36546/Application FU… · Perimeter retaining wall Retaining/boundary walling in brick to match proposed

e

g

16 m²Studio_Mezz

16 m²Studio_Mezz

15 m²Studio_Mezz

dwg title:

job title:

scale:

date:

dwg no:

drawn:

job no:

rev:

oconnell east architects63 Newton Street, Manchester, M1 1ETt: 0161 839 9380 f: 0161 833 1638

oea

oea

All dimensions are in millimetres unless stated otherwise. No dimensions to be scaled from drawings. All dimensions to be checked on site prior to manufacture.

Any discrepancies between drawings and site conditions are to be reported to the contract manager.

This drawing is to be read in conjunction with all relevant Structural Engineers and Mechanical & Electrical Engineers drawings and specification.

Copyright of this drawing and all the information it contains is the sole property of OEA and may not be reproduced or used for any purpose without the express approval of the authors

Notes:

@ A1

dwg status:

C OConnell East Architects - 2015

CNM Capital

1 : 100

5th Floor Mezzanine

Combined Sites St ColumbasClose

JG1675

1675_PL_109

09/14/17

Rev Description Date By Chk

1 : 100Level 5-Mezz1

Page 14: dwg status: PLANNING - Coventrydemocraticservices.coventry.gov.uk/documents/s36546/Application FU… · Perimeter retaining wall Retaining/boundary walling in brick to match proposed

External Finishes

1) Facing Brick2) Feature Brick Panel3) Brick Cill4) Standing Seem Metal Cladding 5) PPC Aluminium Window6) PPC Metal Ventilation Louvres7) Curtain Wall Glazing 8) Balcony Rail Glazing

dwg title:

job title:

scale:date:

dwg no:

drawn:job no:

rev:

oconnell east architects63 Newton Street, Manchester, M1 1ETt: 0161 839 9380 f: 0161 833 1638

oea

dwg status:

O'Connell East Architects - 2016

oeaAll dimensions are in millimetres unless stated otherwise. No dimensions to be scaled from drawings. All dimensions to be checked on site prior to manufacture.

Any discrepancies between drawings and site conditions are to be reported to the contract manager.

This drawing is to be read in conjunction with all relevant Structural Engineers and Mechanical & Electrical Engineers drawings and specification.

Copyright of this drawing and all the information it contains is the sole property of OEA and may not be reproduced or used for any purpose without the express approval of the authors

Notes:

CNM Capital Ltd.

As indicated

A

North-West Elevation

Combined Sites St Columbas Close

JG

1675

1675_PL_111

04/09/2017

North-West Elevation

Approach from the South-East up St Columbas Close

PLANNING

1

74 7 4 5 2 3

St. Columbas Close

8

A

Rev Description Date By Chk

A Low wall added to rear boundary 14.09.17

Page 15: dwg status: PLANNING - Coventrydemocraticservices.coventry.gov.uk/documents/s36546/Application FU… · Perimeter retaining wall Retaining/boundary walling in brick to match proposed

External Finishes

1) Facing Brick2) Feature Brick Panel3) Brick Cill4) Standing Seem Metal Cladding 5) PPC Aluminium Window6) PPC Metal Ventilation Louvres7) Curtain Wall Glazing 8) Balcony Rail Glazing

dwg title:

job title:

scale:date:

dwg no:

drawn:job no:

rev:

oconnell east architects63 Newton Street, Manchester, M1 1ETt: 0161 839 9380 f: 0161 833 1638

oea

dwg status:

O'Connell East Architects - 2016

oeaAll dimensions are in millimetres unless stated otherwise. No dimensions to be scaled from drawings. All dimensions to be checked on site prior to manufacture.

Any discrepancies between drawings and site conditions are to be reported to the contract manager.

This drawing is to be read in conjunction with all relevant Structural Engineers and Mechanical & Electrical Engineers drawings and specification.

Copyright of this drawing and all the information it contains is the sole property of OEA and may not be reproduced or used for any purpose without the express approval of the authors

Notes:

CNM Capital Ltd.

As indicated

A

South-East Elevation

Combined Sites St Columbas Close

JG

1675

1675_PL_112

04/09/2017

South-East Elevation

Approach from the North-West down St Columas Close

PLANNING

54 7 1 7 1 3

St. Columbas Close

8

A

Rev Description Date By Chk

A Low wall added to rear boundary 14.09.17

Page 16: dwg status: PLANNING - Coventrydemocraticservices.coventry.gov.uk/documents/s36546/Application FU… · Perimeter retaining wall Retaining/boundary walling in brick to match proposed

External Finishes

1) Facing Brick2) Feature Brick Panel3) Brick Cill4) Standing Seem Metal Cladding 5) PPC Aluminium Window6) PPC Metal Ventilation Louvres7) Curtain Wall Glazing 8) Balcony Rail Glazing

dwg title:

job title:

scale:date:

dwg no:

drawn:job no:

rev:

oconnell east architects63 Newton Street, Manchester, M1 1ETt: 0161 839 9380 f: 0161 833 1638

oea

dwg status:

O'Connell East Architects - 2016

oeaAll dimensions are in millimetres unless stated otherwise. No dimensions to be scaled from drawings. All dimensions to be checked on site prior to manufacture.

Any discrepancies between drawings and site conditions are to be reported to the contract manager.

This drawing is to be read in conjunction with all relevant Structural Engineers and Mechanical & Electrical Engineers drawings and specification.

Copyright of this drawing and all the information it contains is the sole property of OEA and may not be reproduced or used for any purpose without the express approval of the authors

Notes:

CNM Capital Ltd.

As indicated

A

North-East Elevation

Combined Sites St Columbas Close

JG

1675

1675_PL_113

04/09/2017

North-East Elevation

Approach from the South of the site from neigbouring carpark

PLANNING

3 7 4 5 7 1

A

Rev Description Date By Chk

A Low wall added to rear boundary 14.09.17

Page 17: dwg status: PLANNING - Coventrydemocraticservices.coventry.gov.uk/documents/s36546/Application FU… · Perimeter retaining wall Retaining/boundary walling in brick to match proposed

External Finishes

1) Facing Brick2) Feature Brick Panel3) Brick Cill4) Standing Seem Metal Cladding 5) PPC Aluminium Window6) PPC Metal Ventilation Louvres7) Curtain Wall Glazing 8) Balcony Rail Glazing

dwg title:

job title:

scale:date:

dwg no:

drawn:job no:

rev:

oconnell east architects63 Newton Street, Manchester, M1 1ETt: 0161 839 9380 f: 0161 833 1638

oea

dwg status:

O'Connell East Architects - 2016

oeaAll dimensions are in millimetres unless stated otherwise. No dimensions to be scaled from drawings. All dimensions to be checked on site prior to manufacture.

Any discrepancies between drawings and site conditions are to be reported to the contract manager.

This drawing is to be read in conjunction with all relevant Structural Engineers and Mechanical & Electrical Engineers drawings and specification.

Copyright of this drawing and all the information it contains is the sole property of OEA and may not be reproduced or used for any purpose without the express approval of the authors

Notes:

CNM Capital Ltd.

As indicated

A

South-West Elevation

Combined Sites St Columbas Close

JG

1675

1675_PL_110

04/09/2017

South-West Elevation

Approach from the North-East crossing St Columbas Close

PLANNING

77 71 1 1

6

4 4

5

3 3

8

A

Rev Description Date By Chk

A Low wall added to rear boundary 14.09.17