Page 1: :DWHUZRUNV &DWDORJ - McWane

Waterworks CatalogPC-U2012, January, 2012

www.tylerunion.com

11910 CR 492 • Tyler, Texas 75706 • (800) 527-84781501 West 17th St. • Anniston, Alabama 36201 • (800) 226-76011001 ElCamino Ave • Corona, California 92879 • (866) 527-84716204 N. Marine Drive • Portland, Oregon 97203 • (866) 527-8471

Page 2: :DWHUZRUNV &DWDORJ - McWane

Tyler:  11910 CR 492 • Tyler, Texas 75710 • (800) 527-8478  Anniston:  1501 W. 17th St. • Anniston, AL 36201 • (800) 226-7601Corona: 1001 El Camino Ave. • Corona, CA 92879 • (866) 527-8471  Portland:  6204 N. Marine Dr. • Portland, OR 97203 • (866) 527-8471

www.tylerunion.com

TABLE OF CONTENTS

Municipal Castings:

Boxes: Service Screw Type ............................33  Two-Piece (Screw Type) ................ 34-35  Three-Piece (Screw Type) ............. 38-39  Extensions ...............................40,42,44   Lids (Drop, MWW, Locking, Repair) .....45  Bases (Service Box & Valve Box) ....38,44  Risers (Fixed & Adjustable) .................46  Meter Box, Ring and COver ...............47  Wrenches ................................38,45,4729U-Domestic Valve Box Submittal .........6730U-Non-Domestic Valve Box Submittal .68

Frequently Asked Questions:  About Tyler Union Products ...........53,54  Terms & Conditions of Sale ...........48,49  Product Certification ..........................79

Pressure Pipe Fittings & Restraints:

Pipe and Fittings Restraints ...... 56,57,63,71-78Mechanical Joint-AWWA C153 ................. 3-12Mechanical Joint-AWWA C110 ............... 13-23Push-On Joint ........................................ 24-29Flanged Joint-AWWA C110 .................... 31-37Split Glands .................................................11Tapping Sleeve ........................................12,64Swivel Hydrant Fittings ................ 5-7,22,23,27Companion,Blind & Adapter Flanges ..36,37,50

Submittal, Specifications & Installation20U-Protective Fusion Bonded Epoxy .......58,5921U-Cement Lining & Asphaltic Coating .......6022U-Mechanical Joint C110 .........................6123U-Mechanical Joint C153 .........................6224U-MJ Set Screw Retainer Gland ................6325U-MJ Tapping Sleeve C153 .......................6526U-Union Tite-Push On C153 .....................65        -AWWA C111 Fasteners ........................5528U-Flanged Joint C110 ..............................6631U-Gaskets (Standard & Transition) .......69,70      -Push-On Joint Std. & Restraint ...... 75-7632U-Serrated Clamp Restraint ................ 75-76        -MJ Field LOK Restraining System .... 56-57        -Sure Stop 350 Tyton Restraint Gasket ....77TUF Grip Ductile and PVC Restraints ....... 71-74

<<<<<<<Special Information>>>>>>Flange Data ....................................1,30,31,36Tap Locations for Flanged Fittings .................37Cutting-In Sleeve, Installation .......................10Tapping Sleeve Excavation ............................55Making Offsets on the Job ............................51Pipe O.D. Chart (For Reference Use Only) .....52

Item Page Item Page

NOTICE: (1) Weights published in this catalog are for shipping purposes only. Actual weights may vary as some fittings are produced in multiple foundries. All fittings meet the AWWA standards. For weights of specific fittings, contact Tyler Union Waterworks.

(2) *For the Flange thickness of specific fittings, please contact Tyler Union Waterworks.

Flange Thickness of SSB D.I. Class 350 MJxFlange Fittings

Size  T  Size  T 

  3  .60  14  .87   4  .63  16  .90  6  .63  18  .93   8  .70  20  .96  10  .75  24  1.00   12  .81  36  1.10

*Compact Flange Thickness(+.06")  *See Notice at(-.06")    Bottom of Page

2

Page 3: :DWHUZRUNV &DWDORJ - McWane

3

SAMPLE SPECIFICATIONS (Current ANSI/AWWA revisions apply)

Mechanicaljointwatermainfittingswithaccessories,2"through48"shallbemanufacturedfromductileironinaccordancewithandmeetallapplicabletermsandprovisionsofstandardsANSI/AWWAC153/A21.53and ANSI/AWWAC111/A21.11.Ductileironmechanicaljointfittings2"through24"shallberated for 350 PSIworkingpressure.Ductile iron 30"through48"shallberatedfor250psiworkingpressure.Flangedductile iron fittings in24-in.(610mm)andsmallersizesmayberatedfor350psi(2,413kPa)withtheuseofspecial(annular ring or comparable) gaskets. Allcoatedand lined fittingsmeetrequirementsofNSF-61.

NOTE-EXCEPTIONS:Mechanicaljointfittingswithflangedbranchesareratedforwaterpressureof250PSI.NOTE - Wyes over 12" are not pressure rated. Contact manufacurer for rating in your application.

NOTE -FittingsarecementlinedandsealcoatedinaccordancewithANSI/AWWAC104/A21.4. Fittings are available doublecement-lined,bare,orepoxycoated upon request. Epoxy coating per ANSI/AWWA C116NOTE - Installation per AWWA C600-10

MECHANICAL JOINT C153 DUCTILE IRONCOMPACT FITTINGS

Sizes3"thru16"ULListedForFireMainEquipment

NOMINAL JOINT DIMENSIONS IN INCHES BOLTS

Size ADia. B CDia. DDia. FDia. JDia. K1Dia. K2Dia. L M S T X Size No.

3 3.96 2.50 4.84 4.94 4.06 6.19 7.62 7.69 .58 .62 .39 .33 ¾ Áx3 4

4 4.80 2.50 5.92 6.02 4.90 7.50 9.06 9.12 .60 .75 .39 .34 Â ¾x3½ 4

6 6.90 2.50 8.02 8.12 7.00 9.50 11.06 11.12 .63 .88 .43 .36 Â ¾x3½ 6

8 9.05 2.50 10.17 10.27 9.15 11.75 13.31 13.37 .66 1.00 .45 .38 Â ¾x4 6

10 11.10 2.50 12.22 12.34 11.20 14.00 15.62 15.62 .70 1.00 .47 .40 Â ¾x4 8

12 13.20 2.50 14.32 14.44 13.30 16.25 17.88 17.88 .73 1.00 .49 .42 Â ¾x4 8

14 15.30 3.50 16.40 16.54 15.44 18.75 20.31 20.25 .79 1.25 .55 .47 Â ¾x4½ 10

16 17.40 3.50 18.50 18.64 17.54 21.00 22.56 22.50 .85 1.31 .58 .50 Â ¾x4½ 12

18 19.50 3.50 20.60 20.74 19.64 23.25 24.83 24.75 1.00 1.38 .68 .54 Â ¾x4½ 12

20 21.60 3.50 22.70 22.84 21.74 25.50 27.08 27.00 1.02 1.44 .69 .57 Â ¾x4½ 14

24 25.80 3.50 26.90 27.04 25.94 30.00 31.58 31.50 1.02 1.56 .75 .61 Â ¾x5 16

30 32.00 4.00 33.29 33.46 32.17 36.88 39.12 39.12 1.31 2.00 .82 .66 1¿ 1x6 20

36 38.30 4.00 39.59 39.76 38.47 43.75 46.00 46.00 1.45 2.00 1.00 .74 1¿ 1x6 24

42 44.50 4.00 45.79 45.96 44.67 50.62 53.12 53.12 1.45 2.00 1.25 .82 1À 1¼x6½ 28

48 50.80 4.00 52.09 52.26 50.97 57.50 60.00 60.00 1.45 2.00 1.35 .90 1À 1¼x6½ 32 NOTE: 2 Inch MJ ASTM A536 ductile iron Compact fittings (2"-22.5 bend, 2"-45 bend, 2"-90 bend, 2"x12" solid sleeve, 2"x2" tee, 4"x2" tee, and 4"x2" reducer) will be available beginning 2012. Call Tyler Union for availability and product dimensions.

256772_utility catalog.pdf 3 12/15/08 8:24:18 AM

Page 4: :DWHUZRUNV &DWDORJ - McWane

4

90° Bends (1/4) 45° Bends (1/8) 22½° Bends (1/16) 11¼° Bends (1/32)

Dimensions Dimensions Dimensions DimensionsSize T A R Weight A R Weight A R Weight A R Weight

3 .34 3.5 2.5 19 2.00 2.41 17 1.50 2.51 15 1.25 2.53 16

4 .35 4.0 3.0 22 2.50 3.56 20 1.75 3.81 18 1.50 5.12 18

6 .37 6.5 6.0 49 3.50 7.25 39 2.25 6.35 31 1.50 5.12 29

8 .39 7.5 7.0 64 4.00 8.44 56 2.85 11.80 50 2.06 15.80 45

10 .41 9.5 9.0 102 5.01 10.88 78 3.35 14.35 66 2.32 18.36 59

12 .43 10.5 10.0 129 5.98 13.25 102 3.86 16.90 87 2.56 20.90 82

14 .51 12.0 11.5 214 5.50 12.06 155 3.93 17.25 142 2.59 21.25 136

16 .52 13.0 12.5 273 5.98 13.25 204 3.98 17.50 178 2.62 21.50 157

18 .59 15.5 14.0 411 6.50 12.36 292 7.50 30.19 286 3.00 60.84 283

20 .60 17.0 15.5 519 7.00 13.59 372 8.50 35.19 376 3.50 71.07 374

24 .62 17.0 15.5 721 7.50 14.89 490 9.00 37.69 512 3.50 76.12 487

30.66 21.50 19.0 930 10.50 9.31 716 6.75 21.36 665 4.75 22.84 600

36 .74 24.50 22.0 1450 11.50 21.73 1110 7.75 26.39 960 5.00 25.38 820

42 .82 29.25 26.7 2205 14.00 27.76 1610 9.00 32.68 1350 6.00 35.54 1180

48 .90 33.25 30.75 2990 15.00 30.17 2090 10.00 27.70 1760 6.50 40.61 1475 **Note: 2 Inch Compact ductile iron 22.5, 45, and 90 degeree bends available in 2012. Call Tyler Union for information.

BENDS

MECHANICAL JOINT C153 DUCTILE IRONCOMPACT FITTINGS

Sizes3"thru16"ULListedForFireMainEquipment

*OFFSETS MJ x MJ MJ x PE

Dimensions Weights Size D L1 L MJxMJ MJxPE

4 6 10 -- 42 -- 4 12 16 -- 52 -- 4 18 22 -- 58 -- 4 24 28 -- 70 -- 6 6 12 17.5 50 -- 6 12 18 -- 65 -- 6 18 24 -- 82 -- 6 24 30 -- 91 -- 8 6 13 -- 79 -- 8 12 19 -- 96 -- 8 18 25 -- 116 -- 10 12 21 -- 136 -- 12 6 17 -- 137 -- *NotincludedinAWWAC153.

Page 5: :DWHUZRUNV &DWDORJ - McWane

5

90° Bend MJ x PE (1/4) 45° Bend MJ x PE (1/8) 22½° Bend MJ x PE (1/16) 11¼° Bend MJ x PE (1/32)

Dimensions Dimensions Dimensions Dimensions Size T A Y R Weight A Y R Weight A Y R Weight A Y R Weight

3 .34 3.5 9.0 2.5 18 2.0 7.5 2.41 17 1.50 7.00 2.51 19 1.25 6.75 7.62 15 4 .35 4.0 9.5 3.0 26 2.5 8.0 3.56 22 1.75 7.25 3.81 20 1.50 7.00 5.12 20 6 .37 6.0 11.5 5.0 45 3.2 8.7 5.49 38 2.25 7.75 6.35 33 1.50 7.00 5.12 32 8 .39 7.5 13.0 7.0 64 4.0 9.5 8.44 55 2.84 8.34 11.80 51 2.05 7.55 15.80 4410 .41 9.5 15.0 9.0 108 5.0 10.5 10.88 78 3.35 8.85 14.35 66 2.31 7.81 18.36 6012 .43 9.0 14.4 6.0 114 6.0 11.5 13.25 104 3.50 9.00 12.70 89 2.56 8.06 20.90 7914 .51 12.0 20.0 11.5 219 5.5 13.4 10.85 165 3.93 11.93 17.25 152 2.59 10.59 21.25 13716 .52 13.0 21.0 12.5 254 6.0 14.0 13.25 206 3.98 11.98 17.50 181 2.62 10.62 21.50 16120 .57 15.0 23.0 13.5 400 7.0 15.3 13.97 290 -- -- -- -- -- -- -- -- 24 .62 17.0 25.0 15.5 710 7.5 16.6 14.69 460 9.00 17.66 37.69 455 9.00 26.12 12.00 475 30 .68 21.5 30.5 -- 865 10.5 19.5 -- 715 6.75 15.75 -- 600 -- -- -- --

BENDS

90° Swivel x Swivel Hydrant Ell

DimensionsSize T A B C D E F R*Weight

6 .37 10.5 15.5 6.90 11.2 6.81 7.98 6.0 74

*Weightincludestwoswivelglands.

90° Bend MJ x Flange 45° Bend MJ x Flange 22½° Bend MJ x Flange 11¼° Bend MJ x Flange (1/4) (1/8) (1/16) (1/32)

Dimensions Dimensions Dimensions Dimensions Size T A R F Weight A R F Weight A R F Weight A R F Weight

3 .34 3.5 2.5 5.5 21 ... ... .. .. ... ... .. .. ... ... .. .. 4 .35 4.0 3.0 6.5 28 2.50 3.56 4.0 34 1.75 3.81 4.0 34 1.50 5.12 4.0 19 6 .37 6.0 5.0 8.0 45 3.25 5.49 5.0 57 2.25 5.35 5.0 57 1.50 5.12 5.0 30 8 .39 7.5 7.0 9.0 73 4.25 7.93 5.5 83 2.50 7.62 5.5 83 1.75 7.70 5.5 5010 .41 9.5 9.0 11.0 113 5.00 9.76 6.5 122 3.00 10.16 6.5 122 2.00 10.25 6.5 7512 .43 10.5 10.0 12.0 141 6.0012.19 7.5 159 3.50 12.70 7.5 159 2.25 12.82 7.5 8814 .51 12.0 11.5 14.0 217 5.5010.85 8.5 20716 .52 13.0 12.5 15.0 280 6.0012.02 9.5 290

MECHANICAL JOINT C153 DUCTILE IRONCOMPACT FITTINGS

Sizes3"thru16"ULListedForFireMainEquipment

256772_utility catalog.pdf 5 12/15/08 8:24:18 AM

Page 6: :DWHUZRUNV &DWDORJ - McWane

2"x2" and 4"x2" Compact C153 tees available in 2012. Call Tyler Union for information. 6

TEES

MJ Tee MJ x FE Tee MJ x Swivel Tee Cross

Dimensions Weights Size T T1 H J1 J2 J3 MJ MJxFE †MJxS Cross

3 .34 .34 3.5 3.50 5.5 ... 26 29 ... 31 4x3 .35 .34 3.5 4.00 6.5 ... 35 34 ... 39 4 .35 .35 4.0 4.00 6.5 ... 36 39 ... 45 6x3 .37 .34 4.0 4.00 6.5 ... 51 54 ... ... 6x4 .37 .35 4.0 5.00 8.0 ... 52 57 ... 62 6 .37 .37 5.0 5.00 8.0 10.50 66 68 77 79 8x3 .39 .34 4.0 6.50 9.0 ... 56 ... ... ... 8x4 .39 .35 4.5 6.50 9.0 ... 72 82 ... 84 8x6 .39 .37 5.5 6.50 9.0 11.50 79 81 105 98 8 .39 .39 6.5 6.50 9.0 11.50 90 101 116 112 10x3 .41 .34 4.0 7.50 11.0 ... 80 ... ... ... 10x4 .41 .35 4.5 7.50 11.0 ... 82 92 ... 98 10x6 .41 .37 5.5 7.50 11.0 13.00 99 116 114 121 10x8 .41 .39 6.5 7.50 11.0 13.00 116 128 138 135 10 .41 .41 7.5 7.50 11.0 ... 132 144 ... 156 12x3 .43 .34 4.0 8.75 12.0 ... 99 ... ... ... 12x4 .43 .35 4.5 8.75 12.0 ... 108 118 ... 119 12x6 .43 .37 5.5 8.75 12.0 14.25 119 133 132 138 12x8 .43 .39 6.5 8.75 12.0 14.25 126 146 149 149 12x10 .43 .41 7.5 8.75 12.0 ... 159 174 ... 187 12 .43 .43 8.75 8.75 12.0 ... 171 198 ... 202 14x6 .51 .44 6.5 10.50 14.0 16.00 183 205 211 210 14x8 .51 .45 7.5 10.50 14.0 ... 211 ... ... 231 14x10 .51 .46 8.5 10.50 14.0 ... 229 244 ... 255 14x12 .51 .47 9.5 10.50 14.0 ... 245 284 ... 269 14 .51 .51 10.5 10.50 14.0 ... 281 291 ... 299 16x6 .52 .45 6.5 11.50 15.0 17.00 222 230 243 250 16x8 .52 .46 7.5 11.50 15.0 ... 245 248 ... 264 16x10 .52 .47 8.5 11.50 15.0 ... 265 287 ... 286 16x12 .52 .48 9.5 11.50 15.0 ... 277 312 ... 312 16x14 .52 .51 10.5 11.50 15.0 ... 317 348 ... ... 16 .52 .52 11.5 11.50 15.0 ... 337 324 ... 451 18x6 .59 .44 6.5 14.50 15.5 18.00 275 261 279 ... 18x8 .59 .45 7.5 14.50 14.5 ... 280 351 ... ... 18x10 .59 .47 8.5 12.50 ... ... 286 ... ... ... 18x12 .59 .49 9.5 12.50 ... ... 372 ... ... ... 18x14 .59 .56 10.5 12.50 ... ... 415 ... ... ... 18x16 .59 .57 11.5 12.50 ... ... 445 ... ... ... 18x18 .59 .59 13.0 12.50 ... ... 490 ... ... ... NOTE: Contact TU Inside Sales representative for MJ Crosses larger than 16 inch. †MJxSwl Weights include swivel gland. **NOTE:

CROSS

MECHANICAL JOINT C153 DUCTILE IRONCOMPACT FITTINGS

Sizes3"thru16"ULListedForFireMainEquipment

Page 7: :DWHUZRUNV &DWDORJ - McWane

48x48 .90 .82 33.5 33.5 ... ... 4251 ... ... 7

Swivel x Solid Adapterwith Swivel Gland

Sizeby WallLayingLength Thickness Weight

6x13 .37 52 6x18 .37 65 6x24 .37 69 8x12 .39 52

TEES (Continued)

MJ Tee MJ x FE Tee MJ x Swivel Tee

Dimensions Weights Size T T1 H J1 J2 J3 MJ MJxFE †MJxS

20x6 .60 .44 7.0 16.0 17.0 19.5 335 362 358 20x8 .60 .45 8.0 14.0 ... ... 390 ... ... 20x10 .60 .47 9.0 14.0 ... ... 417 ... ... 20x12 .60 .49 10.0 14.0 ... ... 460 ... ... 20x14 .60 .56 11.0 14.0 ... ... 475 ... ... 20x16 .60 .57 12.0 14.0 ... ... 530 ... ... 20x18 .60 .59 13.0 14.0 ... ... 560 ... ... 20x20 .60 .60 14.0 14.0 ... ... 605 ... ... 24x6 .62 .44 7.0 18.0 19.0 21.5 465 451 457 24x8 .62 .45 8.0 16.0 ... ... 475 ... ... 24x10 .62 .47 9.0 16.0 ... ... 516 ... ... 24x12 .62 .49 10.0 18.0 ... ... 549 580 ... 24x14 .62 .56 11.0 16.0 ... ... 585 ... ... 24x16 .62 .57 12.0 19.5 ... ... 625 744 ... 24x18 .62 .59 13.0 16.0 ... ... 675 ... ... 24x20 .62 .60 15.0 17.0 ... ... 740 ... ... 24x24 .62 .62 17.0 17.0 ... ... 844 ... ... 30x6 .66 .36 7.0 20.0 ... ... 700 ... ... 30x8 .66 .38 8.5 20.0 ... ... 739 ... ... 30x12 .66 .42 10.0 20.0 ... ... 739 ... ... 30x16 .66 .50 12.5 20.0 ... ... 959 ... ... 30x18 .66 .52 14.0 20.0 ... ... 975 ... ... 30x20 .66 .57 15.0 20.0 ... ... 995 ... ... 30x24 .66 .61 16.0 20.0 ... ... 1160 ... ... 30x30 .66 .66 20.0 20.0 ... ... 1323 ... ... 36x12 .74 .50 10.5 23.5 ... ... 1103 ... ... 36x16 .74 .50 12.5 23.5 ... ... 1350 ... ... 36x24 .74 .61 16.0 23.5 ... ... 1498 ... ... 36x30 .74 .66 20.0 23.5 ... ... 1555 ... ... 36x36 .74 .74 23.5 23.5 ... ... 1910 ... ... 42x12 .82 .62 10.0 29.5 ... ... 1410 ... ... 42x24 .82 .62 20.0 30.0 ... ... 2295 ... ... 42x30 .82 .66 22.0 30.0 ... ... 2337 ... ... 42x36 .82 .74 30.0 30.0 ... ... 3000 ... ... 48x12 .90 .62 23.0 32.0 ... ... 2500 ... ... 48x24 .90 .62 33.5 32.0 ... ... 2822 ... ... 48x36 .90 .82 33.5 33.5 ... ... 3982 ... ... 48x42 .90 .82 33.5 33.5 ... ... 4100 ... ...

42x42 .82 .82 30.0 30.0 ... ... 3169 ... ... †MJxSwivel Tee Weights incl. swivel gland.

MJ GLANDS

Glands

Size Weight Size Weight

3 3 18 22 4 4 20 32 6 5 24 37 8 6 30 8510 9 36 11512 10 42 180 14 17 48 27516 21

Swivel x Swivel Adapter Sizeby WallLayingLength Thickness Weight

6x12 .37 28 6x18 .37 49 6x24 .37 52

SwivelGlands,page22RetainerGlands,page10

MECHANICAL JOINT C153 DUCTILE IRONCOMPACT FITTINGS

Sizes3"thru16"ULListedForFireMainEquipment

Page 8: :DWHUZRUNV &DWDORJ - McWane

††

WYES/LATERAL

MJ x MJ PExMJSEB MJLEBxPE PE x PE

Dimensions MJ SEB LEB PE Weights Size T T1 L L L L MJ SEB LEB PE

4x3 .35 .34 3.0 8.5 8.5 14.0 18 17 17 186x3 .37 .34 5.0 10.5 10.5 16.0 28 25 27 206x4 .37 .35 4.0 9.5 9.5 15.0 28 26 27 268x4 .39 .35 5.0 10.5 10.5 16.0 36 34 36 338x6 .39 .37 4.0 9.5 9.5 15.0 39 38 39 3010x4 .41 .35 7.0 12.5 12.5 18.0 53 46 51 ...10x6 .41 .37 5.0 10.5 10.5 16.0 59 48 52 4910x8 .41 .39 4.0 9.5 9.5 15.0 54 52 52 4712x4 .43 .35 9.0 14.5 14.5 20.0 67 61 68 6012x6 .43 .37 7.0 12.5 12.5 18.0 64 58 66 5412x8 .43 .39 5.0 10.5 10.5 16.0 57 62 65 6012x10 .43 .41 4.0 9.5 9.5 15.0 63 61 65 5714x6 .51 .44 9.0 17.0 14.5 22.5 104 107 112 ...14x8 .51 .45 7.0 15.0 12.5 20.5 104 107 108 ...14x10 .51 .46 5.0 13.0 10.5 18.5 100 102 100 ...14x12 .51 .47 4.0 12.0 9.5 17.5 100 101 100 10016x6 .52 .45 11.0 19.0 16.5 24.5 132 131 141 12816x8 .52 .46 9.0 17.0 14.5 22.5 136 128 136 13616x10 .52 .47 7.0 15.0 12.5 20.5 128 124 128 12316x12 .52 .48 5.0 13.0 10.5 18.5 120 123 119 11316x14 .52 .51 4.0 12.0 12.0 20.0 140 139 138 13318x8 .59 .45 14.0 22.0 19.5 27.5 201 180 195 ...18x10 .59 .47 12.0 20.0 17.5 25.5 196 180 185 ...18x12 .59 .49 10.0 18.0 15.5 23.5 175 170 190 ...18x14 .59 .56 8.0 16.0 16.0 24.0 180 181 200 ...18x16 .59 .57 7.0 15.0 15.0 23.0 194 180 190 ...20x10 .60 .47 14.0 22.0 19.4 27.5 225 210 210 ...20x12 .60 .49 12.0 20.0 17.5 25.5 214 208 210 ...20x14 .60 .56 10.0 18.0 17.8 26.0 208 198 205 ...20x16 .60 .57 8.0 16.0 15.8 24.0 225 215 222 ...20x18 .60 .59 7.0 15.0 15.0 23.0 233 220 ... ...24x12 .62 .49 16.0 24.0 21.4 29.5 320 302 300 ...24x14 .62 .56 14.0 22.0 21.8 30.0 314 325 322 ...24x16 .62 .57 12.0 20.0 19.8 28.0 325 319 340 ...24x18 .62 .59 10.0 18.0 18.0 26.0 325 310 ... ...24x20 .62 .60 8.0 16.0 16.0 24.0 315 305 ... ...30x16 .66 .50 30.0 39.0 ... ... 475 565 ... ...30x18 .66 .54 28.0 37.0 ... ... 495 590 ... ...30x20 .66 .57 24.0 33.0 ... ... 525 560 ... ...30x24 .66 .61 10.0 24.5 ... ... 478 495 ... ...36x16 .74 .50 30.0 ... ... ... 789 890 ... ...36x20 .74 .57 36.0 45.0 ... ... 970 874 ... ...36x24 .74 .61 19.0 33.0 ... ... 770 746 ... ...36x30 .74 .66 15.5 24.5 ... ... 838 725 ... ...42x30 .82 .74 20.0 ... ... ...1067 ... ... ... 48x42 .90 .82 15.5 ... ... ... 1486 ... ... ... 8

42x36 .82 .74 15.5 ... ... ... 1116 ... ... ... 48x30 .90 .66 40.0 ... ... ... 1852 ... ... ... 48x36 .90 .74 28.0 ... ... ... 1632 ... ... ...

*Wyes

Dimensions Size A Y T T1 Weights

3 2.5 7.5 .34 .34 36 4x3 2.0 8.5 .35 .34 39 4 2.5 8.5 .35 .35 45 6x4 1.5 11.0 .37 .35 67 6 3.0 13.0 .37 .37 85 8x4 0.5 13.0 .39 .35 86 8x6 2.0 14.5 .39 .37 109 8 3.5 16.0 .39 .39 117 10x4 0.0 15.0 .41 .35 112 10x6 1.0 16.0 .41 .37 129 10x8 2.5 17.0 .41 .39 162 10 3.5 19.0 .41 .41 199 12x4 0.0 16.5 .43 .35 141 12x6 1.5 18.5 .43 .37 170 12x8 1.5 18.5 .43 .39 177 12x10 3.0 20.0 .43 .41 216 12 4.5 22.5 .43 .43 269 14 6.0 25.0 .51 .51 476t16x6 0.0 21.0 .52 .45 300t16x8 0.5 22.5 .52 .46 349 16x12 3.5 25.0 .52 .48 471 16 6.5 28.0 .52 .52 635*NotincludedinAWWAC153.†Ratedat250psi.

REDUCERS

MECHANICAL JOINT C153 DUCTILE IRONCOMPACT FITTINGS

Sizes3"thru16"ULListedForFireMainEquipment

MJ x PE x MJ Tee

Dimensions Size T T1 H J1 Z Weights

6 .37 .37 5.0 5.0 11.5 57 8x6 .39 .37 5.5 6.5 11.5 79 8 .39 .39 6.5 6.5 12.5 83 10 .41 .41 7.5 7.5 13.0 133

MJxFEFlangeDimensionsareoninsidefrontcover.

Page 9: :DWHUZRUNV &DWDORJ - McWane

SOLID & TAPPED PLUGS & CAPS

Short Long

Dimensions Weights Size T L1 L2 Short Long

3 .34 7.5 12 13 22 4 .35 7.5 12 19 25 6 .37 7.5 12 28 39 8 .39 7.5 12 38 55 10 .41 7.5 12 48 68 12 .43 7.5 12 62 81 14 .56 9.5 15 116 146 16 .57 9.5 15 138 174 18 .68 9.5 15 160 230 20 .69 9.5 15 212 269 24 .75 9.5 15 272 380 30 .66 15.0 15 500 ... 30 .66 ... 24 ... 640 36 .74 15.0 15 725 662 36 .74 ... 24 ... 925 42 .82 ... 24 ... 1146 48 .90 ... 24 ... 1455 Note: 2"x12" C153 Sleeves available, call for information ADAPTERS*Note: Verify non domestic laying lengths with Tyler Union

SOLID SLEEVES

MJ x FE FE x PE

Dimensions Weights Size T L1 L2 MJxFE FExPE

3 .34 *6 12 18 ... 4 .35 *6 12 26 23 6 .37 *6 12 36 35 8 .39 *6 12 50 50 10 .41 *6 12 60 69 12 .43 *6 12 88 88 14 .51 *6 12 127 ... 16 .52 *6 12 155 149

18 .56 *6 ... 195 ... ... 30 .66 *7 ... 470 ... 36 .74 *8 ... 750 ... 9

20 .60 *6 ... 275 ... 24 .62 *6 ... 305 ...

MJ Tapped Tee (2" Tap)

Dimensions

Size T L Max.Tap Weights

3 .34 6 2 19 4 .35 6 2 23 6 .37 6 2 35 8 .39 6 2 54 10 .41 6 2 68 12 .43 6 2 88 16 .52 6 2 164

TAPPED TEE

3"-12" 14"-24" 3"-12" 14"-24" MJ Plug MJ Cap

Dimensions Max. Weights Size T Tap Plugs Caps

3 .46 2 9 8 4 .46 2 9 10 6 .46 2 18 18 8 .46 2 25 26 10 .56 2 36 32 12 .56 2 47 46 14 .62 2 76 85 16 .62 2 98 94 18 .65 2 138 121 20 .66 2 158 149 24 .68 2 223 210 30 .66 2 355 345 36 42 48

.74 2 688 626 .82 2 1091 723 .90 2 1455 974

MECHANICAL JOINT C153 DUCTILE IRONCOMPACT FITTINGS

Sizes3"thru16"ULListedForFireMainEquipment

MJxFEFlangeDimensionsareoninsidefront

cover.

Page 10: :DWHUZRUNV &DWDORJ - McWane

10

VALVEINSTALLATIONS

METERSETTINGS

TYPICAL CUTTING-IN SLEEVE INSTALLATIONS

MJ x FE Cutting-InSleevewithDualPurposeAccessories

Dimensions ShippingWt.Size ForPipeSize L L1 T Assembled

4 4.80-5.00O.D. 10 9.5 .35 33 6 6.90-7.10O.D. 10 9.5 .37 50 8 9.05-9.30O.D. 10 9.5 .39 6710 11.10-11.40O.D. 10 9.5 .41 12212 13.20-13.50O.D. 10 9.5 .43 157

FlangedendsarefacedanddrilledperANSI/AWWAC110/A21.10.Mechanicaljointendsaredesignedtoreceivebothstan-dardandoversizegrayorductileironpipeasshownabove.

DUAL PURPOSE CUTTING-IN SLEEVE

Pressure Gland PipeO.D. D.I.Pipe Noof Sizeof Rating, O.D. O.D. Wall Set Set Gland Weight Size psi B A Class Screws Screws Weight w/Acces.

3 350 7.69 3.96 50-56 4 Áx2 5 7 4 350 9.12 4.80 50-56 4 Áx2 6 13 6 350 11.12 6.90 50-56 6 Áx2 11 20 8 250 13.37 9.05 50-56 9 Áx2 13 25 10 250 15.62 11.10 50-56 12 Áx2 18 33 12 150 17.88 13.20 50-56 16 Áx2 23 38 14 250 20.25 15.30 53-56 20 Áx2½ 44 55 16 200 22.50 17.40 53-56 24 Áx2½ 51 64 18 200 24.75 19.50 53-56 24 Áx2½ 62 72 20 200 27.00 21.60 53-56 28 Áx3 73 91 24 150 31.50 25.80 53-56 32 Áx3 93 118*NotincludedinAWWAC110 **Note: Not recommended for plain end fittings

MechanicalJointRetainerGlandsaredesignedtoprovideamethodforrestrain-ingmechanicaljointpipeand**fittingsandotherstandardizedmechanicaljointsagainstpossiblejointseparation,ruptureorblow-outcausedbyinternalwaterpres-sure. Thesetscrewsaresquare-headedwithTypeCknurledcuppoints,andareshippedalreadyassembledintheGlands.Theyaremanufacturedof4140gradealloysteel,andareheattreatedtoaRock-wall“C”45/53casehardness.Tee-headboltsandgasketsarenotincluded,butmaybeorderedseparately.Recommend-edtorqueforsetscrewsis75footpounds,andsetscrewsonoppositesidesoftheglandsshouldbetightenedalternately. Tee-headboltholesizeandspac-ingareequaltoMJGlandsasshowninAWWAC-111.StandardmechanicalJointgasketsasshowninC-111shouldbeused.

DUCTILE IRON RETAINER GLANDS

*SET-SCREW RETAINER GLANDPipeWallThickness:Sizes3"-12"arerecommendedforductileironpipeclass50thru56.Sizes14"thru24"arerecommendedforductileironpipeclass53thru56.

MECHANICAL JOINT C153 DUCTILE IRONCOMPACT FITTINGS

Sizes3"thru16"ULListedForFireMainEquipment

SeeInstallationsInstructions........................................................ Page48

MJxFEFlangeDimensionsareoninsidefront

cover.

256772_utility catalog.pdf 10 12/15/08 8:24:21 AM

Page 11: :DWHUZRUNV &DWDORJ - McWane

MECHANICAL JOINT DUCTILE IRONCOMPACT SPLIT REPAIR GLANDS

6"-8"-10"-12" Sizes

MJ Compact Split Repair Glands

4" Size

SizeInside Diameter Bolt Circle Weight

(+.07-.03) (+-.06) Lbs.4 4.90 7.50 4.06 7.00 9.50 5.08 9.15 11.75 6.0

10 11.20 14.00 7.7 12 12.50 16.25 10.2

Split glands work with standard MJ gaskets and standard T-head bolts. Glands are shipped in halves and do not need separate bolts. T-head

bolts alone hold the halves together. 11

Page 12: :DWHUZRUNV &DWDORJ - McWane

12

COMPACT DUCTILE IRON MJ TAPPING SLEEVES

SAMPLE SPECIFICATION (Current ANSI/AWWA revisions apply)DuctileironmechanicaljointtappingsleevesfurnishedbyTylerUnion Waterworks areproducedinaccordancewithmanufacturer'sstandards.Chemicalandphysicalpropertiesoftheductileironareinaccordance with therequirementsofANSI/AWWAC153/A21.53 and ASTM A536. Coatings are NSF-61 approved and conform withAWWA C104. Flange recessdimensionsperMSS SP-60. Tapping sleeve meets requirements of MSS SP-111

General Installation Instructions for Tyler Union Waterworks MJ Tapping Sleeves1.Cleanpipe-insertsidegasketintobackhalfofgasketgrooves.Makesureendsareflushwithorslightlypro-trudeintotheendgasketseatingarea.2.Boltsleevehalvestogetherandtrimsidegasketsasnecessary.MAKESURESLEEVEWILLROTATEFREELYONPIPE.3.Installendgaskets,locatingcutends90°fromsidegasket.IfpipeismaximumOD,stretch gaskettomakecertaincutendsmatchwithno gapinbetween.4.Installglandsandbolts-rotatesleevetodesiredposition.Besurepipeiscenteredinsidethesleeve.5.Tightenglandboltsalternately,using80to90footpounds.6.Afterassembly,PRESSURETESTALLJOINTSBE-FORETAPPING.Ifadditionaltighteningis required,releasepressureandrelaxtensiononglandboltsbeforetighteningsidebolts.

ForCastIron,DuctileIron, and PVC C900/905PipeMechanicaljointtappingsleeves-for6"through12"castiron,ductileiron, or PVCpipe.OutletflangeperANSI/AWWAC153/A21.53Gasketsfurnished meet AWWAC111 and ASTM D2000-AA.Workingpressure-250p.s.i.Gaskets available in SBR onlyJoint deflection is not recommended

TappingSleevefor CastIron/DuctileIron

O.D.Range Dimensions DI Weight Size A B C D E F Min. Max. DI

6x4 5.016 .250 7.50 15.75 8.00 12.75 6.85 7.15 104 6 7.016 .312 9.50 15.75 8.00 12.75 6.85 7.15 108 8x4 5.016 .250 7.50 16.50 9.00 13.50 9.00 9.35 134 8x6 7.016 .312 9.50 16.50 9.00 13.50 9.00 9.35 140 8 9.016 .312 11.75 16.50 9.00 13.50 9.00 9.35 148 10x4 5.016 .250 7.50 24.00 11.00 20.75 11.04 11.45 236 10x6 7.016 .312 9.50 24.00 11.00 20.75 11.04 11.45 240 10x8 9.016 .312 11.75 24.00 11.00 20.75 11.04 11.45 246 10 11.016 .312 14.25 24.00 11.00 20.75 11.04 11.45 257 12x4 5.016 .250 7.50 26.50 12.00 23.25 13.14 13.56 273 12x6 7.016 .312 9.50 26.50 12.00 23.25 13.14 13.56 286 12x8 9.016 .312 11.75 26.50 12.00 23.25 13.14 13.56 292 12x10 11.016 .312 14.25 26.50 12.00 23.25 13.14 13.56 303 12 13.016 .312 17.00 26.50 12.00 23.25 13.14 13.56 320

256772_utility catalog.pdf 12 12/15/08 8:24:21 AM

Page 13: :DWHUZRUNV &DWDORJ - McWane

13

ANSI/AWWAC110/A21.10,ANSI/AWWAC111/A21.11

SAMPLE SPECIFICATION (Current ANSI/AWWA revision apply)Mechanicaljointwatermainfittingswithaccessories,2"through48"shallbeproducedofductileironinaccordancewithand meetallapplicabletermsandprovisionsofstandardsANSI/AWWAC110/A21.10 andANSI/AWWAC111/A21.11.Ductileironmechanicaljointfittings3"through24"shallberatedfor350PSIworkingpressure.AllductileironmechanicalJointfittings30"through48"shallberatedfor250PSIworkingpressure.Flangedductile-ironfittingsin24-in.(610mm)andsmallersizesmayberatedfor350psi(2,413kPa)withtheuseofspecial(annular ring or comparable) gaskets.

NOTE-EXCEPTIONS:MechanicalJointFittingswithflangedbranchesand14"andlargercapsandplugsareratedforwater pressureof250PSI.NOTE - Installation per AWWA C600-10 NOTE:Fittingsarecement linedandsealcoatedinaccordancewithANSI/AWWAC104/A21.4. Fittings are alsoavailable double cement lined,bareorepoxycoated.Allcoated and linedfittingsmeetrequirementsofNSF-61.

NOMINAL JOINT DIMENSIONS IN INCHES - MECHANICAL JOINT FITTINGSDIMENSIONS IN INCHES

Size A B C D F Ø X J K1 K2 L M N O P S

*2 2.50 2.50 3.39 3.50 2.61 28° ¾ 4.75 6.25 6.25 .75 .62 1.12 .31 .63 .44 3 3.96 2.50 4.84 4.94 4.06 28° ¾ 6.19 7.69 7.69 .94 .62 1.37 .31 .63 .52 4 4.80 2.50 5.92 6.02 4.90 28° Â 7.50 9.12 9.12 1.00 .75 1.50 .31 .75 .65 6 6.90 2.50 8.02 8.12 7.00 28° Â 9.50 11.12 11.12 1.06 .88 1.63 .31 .75 .70 8 9.05 2.50 10.17 10.27 9.15 28° Â 11.75 13.37 13.37 1.12 1.00 1.75 .31 .75 .7510 11.10 2.50 12.22 12.34 11.20 28° Â 14.00 15.69 15.62 1.19 1.00 1.75 .31 .75 .8012 13.20 2.50 14.32 14.44 13.30 28° Â 16.25 17.94 17.88 1.25 1.00 1.75 .31 .75 .8514 15.30 3.50 16.40 16.54 15.44 28° Â 18.75 20.31 20.25 1.31 1.25 2.00 .31 .75 .8916 17.40 3.50 18.50 18.64 17.54 28° Â 21.00 22.56 22.50 1.38 1.31 2.06 .31 .75 .9718 19.50 3.50 20.60 20.74 19.64 28° Â 23.25 24.83 24.75 1.44 1.38 2.13 .31 .75 1.0520 21.60 3.50 22.70 22.84 21.74 28° Â 25.50 27.08 27.00 1.50 1.44 2.19 .31 .75 1.1224 25.80 3.50 26.90 27.04 25.94 28° Â 30.00 31.58 31.50 1.62 1.56 2.31 .31 .75 1.2230 32.00 4.00 33.29 33.46 32.17 20° 1¿ 36.88 39.12 39.12 1.81 2.00 2.75 .38 1.00 1.5036 38.30 4.00 39.59 39.76 38.47 20° 1¿ 43.75 46.00 46.00 2.00 2.00 2.75 .38 1.00 1.8042 44.50 4.00 45.79 45.96 44.67 20° 1À 50.62 53.12 53.12 2.00 2.00 2.75 .38 1.00 1.9548 50.80 4.00 52.09 52.26 50.97 20° 1À 57.50 60.00 60.00 2.00 2.00 2.75 .38 1.00 2.20

*NotincludedinAWWAC110.

DUCTILE IRON C110 FULL BODYMECHANICAL JOINT DIMENSIONS Sizes 3" thru 12" UL Listed for Fire Main Equipment

ACCESSORIES AND WEIGHTS

Wt.ofGland, Pipe Bolt Bolt BoltTorque Boltsand BarrelSize No. Size Length Ft/Lbs. Gasket,Lbs. O.D.

*2 2 Á 3 45-60 5 2.50 3 4 Á 3 45-60 7 3.96 4 4 ¾ 3½ 75-90 10 4.80 6 6 ¾ 4 75-90 16 6.90 8 6 ¾ 4 75-90 25 9.0510 8 ¾ 4 75-90 30 11.1012 8 ¾ 4 75-90 40 13.2014 10 ¾ 4½ 75-90 45 15.3016 12 ¾ 4½ 75-90 55 17.4018 12 ¾ 4½ 75-90 65 19.5020 14 ¾ 4½ 75-90 85 21.6024 16 ¾ 5 75-90 105 25.8030 20 1 6 100-120 220 32.0036 24 1 6 100-120 301 38.3042 28 1¼ 6½ 120-150 389 44.5048 32 1¼ 6½ 120-150 477 50.80

*NotincludedinAWWAC110.

14"THRU48"GLANDSMAYBETAPERED

256772_utility catalog.pdf 13 12/15/08 8:24:22 AM

Page 14: :DWHUZRUNV &DWDORJ - McWane

14

ANSI/AWWAC110/A21.10,ANSI/AWWAC111/A21.11

BENDS90° Bends (1/4)

Dimensions WeightsSize R Y Z MJxMJ MJxPE MJxFE

*2 2.25 3.25 ... 16 ... ... 3 4.0 5.5 13.5 26 36 ... 4 4.5 6.5 14.5 56 53 51 6 6.0 8.0 16.0 88 80 75 8 7.0 9.0 17.0 123 119 11810 9.0 11.0 19.0 189 181 16812 10.0 12.0 20.0 268 252 28814 11.5 14.0 22.0 380 ... ...16 12.5 15.0 23.0 552 470 46518 14.0 16.5 24.5 625 600 57720 15.5 18.0 26.0 862 775 ...24 18.5 22.0 30.0 1423 1301 115030 21.5 25.0 33.0 1942 1920 ...36 24.5 28.0 36.0 2629 2310 ...42 27.5 31.0 3410 ... ...48 30.5 34.0 4595 ... ...

90°MJxFE(1/4)

90°MJxPE(1/4)

MechanicalJointweightsdonotincludeGlands,Nuts,BoltsandGaskets.SeeJointAccessories.

ForsizesnotfoundinthissectioncheckMJ-SSBDIfittings,pages3thru11.

90°MJxMJ(1/4)

DUCTILE IRON C110 FULL BODYMECHANICAL JOINT FITTINGS

MJxFIPTECCENTRICREDUCER

Dimensions Size L Weights

6x2 13 51 8x2 15 71

256772_utility catalog.pdf 14 12/15/08 8:24:22 AM

Page 15: :DWHUZRUNV &DWDORJ - McWane

15

ANSI/AWWAC110/A21.10,ANSI/AWWAC111/A21.11

BENDS

22½° Bends (1/16)

Dimensions WeightsSize R Y Z MJ MJxFE* MJxPE

3 7.56 3.0 11.0 30 ... ... 4 10.06 4.0 12.0 52 ... ... 6 15.06 5.0 13.0 77 71 70 8 17.62 5.5 13.5 110 107 10910 22.62 6.5 14.5 156 155 16312 27.62 7.5 15.5 221 215 22414 25.12 7.5 15.5 300 ... ...16 27.62 8.0 16.0 391 315 36518 30.19 8.5 16.5 527 422 45520 35.19 9.5 17.5 611 ... 57524 37.69 11.0 19.0 986 800 93030 57.81 15.0 23.0 1898 ... 154036 72.88 18.0 26.0 2372 ... 197042 88.00 21.0 3020 ... ...48 103.06 24.0 4170 ... ...

45° Bends (1/8)

Dimensions WeightsSize R Y Z MJ MJxFE* MJxPE

*2 1.96 1.8 ... 16 ... ... 3 3.62 3.0 11.0 30 ... ... 4 4.81 4.0 12.0 53 48 45 6 7.25 5.0 13.0 77 60 69 8 8.44 5.5 13.5 110 107 11110 10.88 6.5 14.5 172 168 16712 13.25 7.5 15.5 222 215 21814 12.06 7.5 15.5 311 ... ...16 13.25 8.0 16.0 364 360 36018 14.50 8.5 16.5 531 430 45520 16.88 9.5 17.5 655 543 66424 18.12 11.0 19.0 865 1099 82530 27.75 15.0 23.0 1447 ... 151036 35.00 18.0 26.0 2435 ... 193042 42.25 21.0 2955 ... ...48 49.50 24.0 4080 ... ...

*NotincludedinAWWAC110.

11¼° Bends (1/32)

Dimensions WeightsSize R Y Z MJ MJxFE* MJxPE

3 15.25 3.0 11.0 30 ... ... 4 20.31 4.0 12.0 52 ... ... 6 30.50 5.0 13.0 65 71 ... 8 35.50 5.5 13.5 104 105 ...10 45.69 6.5 14.5 171 ... ...12 55.81 7.5 15.5 221 215 ...14 50.75 7.5 15.5 305 ... ...16 55.81 8.0 16.0 391 367 ...18 60.94 8.5 16.5 525 422 ...20 71.06 9.5 17.5 605 ... ...24 76.12 11.0 19.0 996 800 97230 116.75 15.0 23.0 1410 ... 130536 147.25 18.0 26.0 2397 ... 218542 177.69 21.0 3035 ... ...48 208.12 24.0 4190 ... ...

45° MJ (1/8) 45° MJ x PE (1/8)

45° MJ x FE (1/8)

22½° MJ (1/16) 22½° MJ x PE (1/16)

11¼° MJ x FE (1/32)

11¼° MJ (1/32)

22½° MJ x FE (1/16)

DUCTILE IRON C110 FULL BODYMECHANICAL JOINT FITTINGS

11¼° MJ x PE (1/32)

256772_utility catalog.pdf 15 12/15/08 8:24:22 AM

Page 16: :DWHUZRUNV &DWDORJ - McWane

16

ANSI/AWWAC110/A21.10,ANSI/AWWAC111/A21.11

Size Dimensions Weights Run Run Branch X Y Z MJ **MJxPExMJ **MJxMJxFE

*2 2 2 3.25 3.25 ... 21 ... ... *3 3 2 3.25 3.25 ... 45 ... ... 3 3 3 5.5 5.5 13.5 58 ... ... *4 4 2 4.8 4.8 14.5 68 ... 49 4 4 3 6.5 6.5 14.5 77 ... ... 4 4 4 6.5 6.5 14.5 78 75 76 4 4 6 8.0 8.0 ... 112 ... ... *6 6 2 8.0 8.0 ... 78 ... ... 6 6 3 8.0 8.0 16.0 112 ... ... 6 6 4 8.0 8.0 16.0 110 ... 109 6 6 6 8.0 8.0 16.0 119 120 141 6 6 8 9.0 9.0 ... 158 ... ... 8 8 3 9.0 9.0 17.0 155 ... ... 8 8 4 9.0 9.0 17.0 157 ... 150 8 8 6 9.0 9.0 17.0 175 170 182 8 8 8 9.0 9.0 17.0 199 180 194 10 10 4 11.0 11.0 19.0 ... ... 229 10 10 6 11.0 11.0 19.0 258 ... 264 10 10 8 11.0 11.0 19.0 268 ... 245 10 10 10 11.0 11.0 19.0 300 250 ... 12 12 4 12.0 12.0 20.0 318 315 323 12 12 6 12.0 12.0 20.0 325 325 335 12 12 8 12.0 12.0 20.0 335 335 372 12 12 10 12.0 12.0 20.0 392 390 ... 12 12 12 12.0 12.0 20.0 396 396 476 14 14 12 14.0 14.0 22.0 540 560 ... 14 14 14 14.0 14.0 22.0 585 570 ... *16 16 4 15.0 15.0 23.0 600 580 575 16 16 6 15.0 15.0 23.0 615 590 605 16 16 8 15.0 15.0 23.0 625 605 615 16 16 10 15.0 15.0 23.0 645 620 ... 16 16 12 15.0 15.0 23.0 660 640 651 16 16 16 15.0 15.0 23.0 740 720 730

MJxMJxFE

Bullhead

Straight Tees andReducing on Branch Tees

TEES

DUCTILE IRON C110 FULL BODYMECHANICAL JOINT FITTINGS

MJ Tapped Tee (2"Tap)

DimensionsSize L Max.Tap Weights

3 8 2 40 4 8 2 51 6 8 2 73 8 8 2 10410 8 2 13012 8 2 180

MJ TAPPED TEE

ForsizesnotfoundinthissectioncheckMJ-SSBDIfittings,pages3thru11.

NOTICE:Weightspublishedinthiscatalogareforshippingpurposesonly.Actualweightsmayvary becausesomefittingsareproducedinmultiplefoundries.AllfittingsmeettheAWWA standards to which they aredesigned. Forweightsofspecificfittings,pleasecontactTylerUnion WaterworksCompany. *Not included in AWWA C110 **Made to order only. Not Returnable

256772_utility catalog.pdf 16 12/15/08 8:24:22 AM

Page 17: :DWHUZRUNV &DWDORJ - McWane

17

ANSI/AWWAC110/A21.10,ANSI/AWWAC111/A21.11

TEES (Con't) Size Dimensions Weights Run Run Branch X Y Z MJ **MJxPExMJ **MJxMJxFE

18 18 6 13.0 15.5 ... 710 ... 707 18 18 8 13.0 15.5 ... 674 ... 675 18 18 12 13.0 15.5 ... 749 ... 733 18 18 18 16.5 16.5 ... 945 ... 953 20 20 6 14.0 17.0 ... 849 ... ... 20 20 8 14.0 17.0 ... 892 ... 859 20 20 12 14.0 17.0 ... 896 ... ... 20 20 16 18.0 18.0 ... 1095 ... ... 20 20 20 18.0 18.0 ... 1258 ... 1168 24 24 6 15.0 19.0 ... 1233 ... 1228 24 24 8 15.0 19.0 ... 1234 ... 1242 24 24 12 15.0 19.0 ... 1256 ... 1165 24 24 14 15.0 19.0 ... 1220 ... ... 24 24 16 15.0 19.0 ... 1245 ... ... 24 24 18 22.0 22.0 ... 1735 ... ... 24 24 20 22.0 22.0 ... 1720 ... ... 24 24 24 22.0 22.0 ... 1947 ... 1795 30 30 6 18.0 23.0 ... 2050 ... ... 30 30 8 18.0 23.0 ... 2060 ... ... 30 30 10 18.0 23.0 ... 2075 ... ... 30 30 12 18.0 23.0 ... 2090 .... ... 30 30 16 18.0 23.0 ... 2145 ... ... 30 30 18 18.0 23.0 ... 2170 ... ... 30 30 20 18.0 23.0 ... 2205 ... ... 30 30 24 25.0 25.0 ... 2880 ... ... 30 30 30 25.0 25.0 ... 2275 ... 3080 36 36 6 20.0 26.0 ... 2439 ... 2430 36 36 8 20.0 26.0 ... 2444 ... ... 36 36 10 20.0 26.0 ... 2535 ... ... 36 36 12 20.0 26.0 ... 2541 ... 2550 36 36 14 20.0 26.0 ... 2570 ... ... 36 36 16 20.0 26.0 ... 2585 ... 2450 36 36 18 20.0 26.0 ... 2610 ... ... 36 36 20 20.0 26.0 ... 2635 ... ... 36 36 24 20.0 26.0 ... 2792 ... 2660 36 36 30 28.0 28.0 ... 3545 ... ... 36 36 36 28.0 28.0 ... 3450 ... ... 42 42 24 23.0 30.0 ... 3690 ... ... 42 42 30 31.0 31.0 ... 4650 ... ... 42 42 36 31.0 31.0 ... 4880 ... ... 42 42 42 31.0 31.0 ... 6320 ... ... 48 48 24 26.0 34.0 ... 4995 ... ... 48 48 30 26.0 34.0 ... 5140 ... ... 48 48 36 34.0 34.0 ... 6280 ... ... 48 48 42 34.0 34.0 ... 8130 ... ... 48 48 48 34.0 34.0 ... 8420 ... ...

*NotincludedinAWWAC110 **Madetoorderonly.NotReturnable

DUCTILE IRON C110 FULL BODYMECHANICAL JOINT FITTINGS

MJxMJxFE

Bullhead

Straight Tees andReducing on Branch Tees

256772_utility catalog.pdf 17 12/15/08 8:24:22 AM

Page 18: :DWHUZRUNV &DWDORJ - McWane

18

ANSI/AWWAC110/A21.10,ANSI/AWWAC111/A21.11

ALL MJ *MJ x MJ x FE x FE

CROSSES

For sizes not found in this section check MJ-C153 sec.

Size Dimensions Weights Run Branch X Y MJ *MJxFE

6 6 8.0 8.0 160 141 8 4 9.0 9.0 185 .... 8 6 9.0 9.0 205 182 8 8 9.0 9.0 255 245 10 6 11.0 11.0 285 .... 10 8 11.0 11.0 310 .... 10 10 11.0 11.0 380 360 12 6 12.0 12.0 361 367 12 8 12.0 12.0 371 373 12 12 12.0 12.0 486 487 14 8 14.0 14.0 550 .... 14 14 14.0 14.0 779 .... 16 6 15.0 15.0 650 .... 16 8 15.0 15.0 675 655 16 16 15.0 15.0 895 875 18 8 13.0 15.5 775 .... 18 10 13.0 15.5 760 .... 18 12 13.0 15.5 860 .... 18 18 16.5 16.5 1140 .... 20 8 14.0 17.0 951 .... 20 12 14.0 17.0 977 .... 20 16 18.0 18.0 1245 .... 20 20 18.0 18.0 1440 .... 24 8 15.0 19.0 1244 .... 24 12 15.0 19.0 1326 .... 24 16 15.0 19.0 1479 .... 24 20 22.0 22.0 1965 .... 24 24 22.0 22.0 2192 .... 30 6 18.0 23.0 2085 .... 30 12 18.0 23.0 2165 .... 30 24 25.0 25.0 3180 .... 30 30 25.0 25.0 3640 .... 36 24 20.0 26.0 2910 .... 36 36 28.0 28.0 4370 .... 42 42 31.0 31.0 7145 .... 48 24 26.0 34.0 5210 ....

48 36 34.0 34.0 6790 .... 48 48 34.0 34.0 9380 .... *Not included in AWWAC110.

Size Dimensions Run Branch X Z Weights

3 3 10.0 3.0 60

4 4 12.0 3.0 90

6 4 14.5 3.5 130 6 6 14.5 3.5 145 8 4 17.5 4.5 190 8 6 17.5 4.5 205 8 8 17.5 4.5 230 10 6 20.5 5.0 330 10 8 20.5 5.0 310 10 10 20.5 5.5 435 12 8 24.5 5.5 505 12 12 24.5 5.5 490 14 6 27.0 6.0 626 16 16 30.0 6.5 1079 18 8 32.0 7.0 1073 18 10 32.0 7.0 975 18 12 32.0 7.0 1015 18 16 32.0 7.0 1135 18 18 32.0 7.0 1130 20 10 35.0 8.0 1220 20 12 35.0 8.0 1260 20 16 35.0 8.0 1375 20 20 35.0 8.0 1525 24 24 40.5 9.0 2372 30 30 49.0 10.0 3670 36 24 54.0 15.0 5390 36 36 60.0 19.5 6335 42 24 60.0 12.0 6810 42 30 63.0 12.0 7210 42 36 66.0 12.0 8355 42 42 71.0 15.0 9900 48 48 77.0 16.0 13150

WYES/LATERAL(NotincludedinAWWAC110.)

DUCTILE IRON C110 FULL BODYMECHANICAL JOINT FITTINGS

Page 19: :DWHUZRUNV &DWDORJ - McWane

19

ANSI/AWWAC110/A21.10,ANSI/AWWAC111/A21.11

REDUCERS

Plain End-Plain End Reducer

MJ Reducer

MJ Small End Bell Reducer

MJ Large End Bell Reducer

FExMJ Reducer

MJxFE Reducer

Laying Lengths (L) Weights

Size MJ MJ-SEB MJ-LEB PExPE FExMJ MJxFE MJ MJ-SEB MJ-LEB PExPE FExMJ MJxFE

*3x2 6 14 14 ... ... ... 24 24 24 ... ... ...*4x2 7 15 15 ... ... ... 31 30 31 ... ... ...4x3 7 15 15 23 7 7 37 38 37 34 34 35*6x2 9 17 17 ... ... ... 46 43 47 ... ... ...6x3 9 17 17 25 ... 9 55 50 55 ... ... 506x4 9 17 17 25 9 9 56 60 59 57 53 628x3 11 19 19 27 ... ... 84 77 70 ... ... ...8x4 11 19 19 27 11 11 84 82 84 ... 73 758x6 11 19 19 27 11 11 94 90 93 96 84 8010x6 12 20 20 28 12 12 115 116 117 ... 100 10510x8 12 20 20 28 12 12 142 135 130 135 130 13012x4 14 22 22 30 ... ... 139 131 ... ... ... ...12x6 14 22 22 30 14 12 148 150 153 ... 145 13012x8 14 22 22 30 14 12 173 168 165 168 170 17512x10 14 22 22 30 14 12 194 190 178 185 188 19014x6 16 24 24 32 ... 16 ... ... ... ... ... 19514x8 16 24 24 32 ... 16 ... ... ... ... ... 21514x12 16 24 24 32 ... 16 ... ... ... ... ... 27016x6 18 26 26 34 ... ... 250 ... ... ... ... ...16x8 18 26 26 34 ... ... 288 248 ... ... ... ...16x10 18 26 26 34 ... ... 300 ... ... ... ... ...16x12 18 26 26 34 18 18 330 304 325 ... 305 32516x14 18 26 26 34 ... ... 370 ... ... ... ... ...18x8 19 27 27 35 ... 19 320 ... ... ... ... 30018x10 19 27 27 35 ... ... 388 ... ... ... ... ...18x12 19 27 27 35 ... 19 380 355 ... ... ... 40518x14 19 27 27 35 ... ... 450 ... ... ... ... ...18x16 19 27 27 35 ... 19 476 ... ... ... ... 44520x10 20 28 28 36 ... ... 410 ... ... ... ... ...20x12 20 28 28 36 ... ... 515 420 ... ... ... ...20x16 20 28 28 36 ... 20 578 525 510 ... ... 51020x18 20 28 28 36 ... ... 575 ... ... ... ... ...24x12 24 32 32 40 ... 24 610 570 ... ... ... 45524x16 24 32 32 40 ... ... 705 665 753 ... ... ...24x18 24 32 32 40 ... ... 789 720 ... ... ... ...24x20 24 32 32 40 ... ... 815 775 804 ... ... ...*30x16 30 38 38 46 ... ... 1150 1040 ... 1015 ... ...30x18 30 38 38 46 ... ... 1160 1050 ... 1025 ... ...30x20 30 38 38 46 ... ... 1225 1120 ... 1090 ... ...30x24 30 38 38 46 ... ... 1360 1255 1320 1215 ... ...36x20 36 44 44 52 ... ... 1495 ... 1466 ... ... ...36x24 36 44 44 52 ... ... 1580 ... 1535 1389 ... ...36x30 36 44 44 52 ... ... 1919 1721 ... 1585 ... ...42x24 42 50 50 58 ... ... 2060 ... ... ... ... ...42x30 42 50 50 58 ... ... 2370 ... ... ... ... ...42x36 42 50 50 58 ... ... 2695 ... ... ... ... ...48x30 48 56 56 64 ... ... 3005 ... ... ... ... ...48x36 48 56 56 64 ... ... 3370 ... ... ... ... ...48x42 48 56 56 64 ... ... 3750 ... ... ... ... ...

* NotincludedinAWWAC110

DUCTILE IRON C110 FULL BODYMECHANICAL JOINT FITTINGS

Page 20: :DWHUZRUNV &DWDORJ - McWane

20

ANSI/AWWAC110/A21.10,ANSI/AWWAC111/A21.11

DUCTILE IRON C110 FULL BODYMECHANICAL JOINT FITTINGS

SOLID SLEEVES

* MJ x PE DUAL-PURPOSE CUTTING-IN SLEEVEWithDual-PurposeAccessories(NOTES:Glandwithcup-jointsetscrewsavailableatextracostwhenspecified.NOTFORRESTRAINT.)Currently,TylerandUnionDualPurposeGlandsareNOTinterchangeable.

Cutting-In Sleeve&Gland

Weight ForUse Gland Gland Size OnPipeO.D. L L1 D Only &Sleeve

4 4.80-5.00 12 8 4.80 6.0 72 6 6.90-7.10 12 8 6.90 10.0 94 8 9.05-9.30 12 8 9.05 16.0 122 10 11.10-11.40 12 8 11.10 25.0 175 12 13.20-13.50 12 8 13.20 30.0 235

*NotincludedinAWWAC110.

Standard

Pipe Short Long Size O.D. L Weight L Weight

*2 2.50 8.0 13 12 18 3 3.96 7.5 25 12 36 4 4.80 7.5 35 12 47 6 6.90 7.5 45 12 65 8 9.05 7.5 65 12 90 10 11.10 7.5 85 12 115 12 13.20 7.5 120 12 136 16 17.40 9.5 206 15 281 18 19.50 9.5 246 15 362 20 21.60 9.5 275 15 404 24 25.80 9.5 360 15 540 30 32.00 15.0 745 24 1085 36 38.30 15.0 1047 24 1502 42 44.50 15.0 1312 24 1550 48 50.80 15.0 1585 24 1940

*NotincludedinAWWAC110

* Dual Purpose †

Pipe Short LongSize O.D. L Weight L Weight

4 4.80/5.00 7.5 33 12 44 6 6.90/7.10 7.5 46 12 63 8 9.05/9.30 7.5 65 12 88 10 11.10/11.40 ... ... 12 111†12 13.20/13.50 ... ... 12 221†16 17.40/17.80 ... ... 15 385

AllSizesUseMJDualPurposeGland*NotincludedinAWWAC110†12"&16"aresoldassembledNOTE:Sizes4-10"usestandardMJGaskets;

12"and16"requirespecialduogaskets.

MJxFE

Dimensions Size L Weights

3 8 30 4 8 42 6 8 62 8 8 88 10 8 120 12 8 150 16 8 257 18 8 324 20 8 365 24 8 528 30 10 760 36 10 1070

ADAPTERS

256772_utility catalog.pdf 20 12/15/08 8:24:23 AM

Page 21: :DWHUZRUNV &DWDORJ - McWane

21

ANSI/AWWAC110/A21.10,ANSI/AWWAC111/A21.11

Solid or Tapped

WeightSize Tap Solid Tapped

*2 2 5 5 3 2 9 9 4 2 13 14 6 2 15 15 8 2 45 45 10 2 66 66 12 2 79 79 14 2 120 120 16 2 147 147†18 2 192 190†20 2 220 219†24 2 338 338†30 2 660 660†36 2 838 838 †42 ... 1180 ... †48 ... 1455 ...

† Dished–Notflatasshown.* Notincludedin AWWAC110.

PLUGS OFFSETS

MJ x MJ MJ x PE

Dimensions Weights Size D L1 L MJxMJ MJxPE

4 6 19 27 ... 82 4 12 22 30 85 80 4 18 30 38 105 ...*4 24 26 34 126 125 6 6 20 28 114 105 6 12 26 34 148 143 6 18 33 41 188 176*6 24 24 32 182 160 8 6 21 29 177 155 8 12 28 36 231 195 8 18 35 43 287 282*8 24 36 44 280 285 10 12 30 38 347 280 10 18 38 46 340 340 10 24 38 46 420 ... 12 12 37 45 420 420 12 18 48 56 520 520*12 24 48 56 649 630 16 12 40 48 715 ... 16 18 50 58 850 830*20 12 40 48 1025 ...*20 18 48 60 1362 ...

*NotincludedinAWWAC110.

CAPS

Solid or Tapped

WeightSize Tap Solid Tapped

*2 2 6 ... 3 2 10 10 4 2 18 13 6 2 34 30 8 2 46 45 10 2 58 54 12 2 86 80 16 2 178 175†18 2 215 215†20 2 250 249†24 2 370 370†30 2 680 680†36 2 850 850 42 .. 1180 ... 48 .. 1595 ...

†Dished–Notflatasshown.* Notincludedin AWWAC110.

DUCTILE IRON C110 FULL BODYMECHANICAL JOINT FITTINGS

TYTON® Plug**Solid or Tapped

Size Tap T Weight*

4 2 .60 18 6 2 .65 25 8 2 .70 46 10 2 .75 70 12 2 .75 95

* Weightsdonotincludeaccessories**NotincludedinAWWAC110. TYTON®isaregisturedtrademarkofU.S.PipeandFoundryCompany.

Push-InPlugwithEars(Tobeusedwithallpush-in

pipeandfittings)

Size Tap Weight

14 2.0 101 16 2.0 137 18 2.0 177†20 2.0 239†24 2.0 311

† Dished-NotflatasshownNOTE:Blockingstillrequired–earsforassemblyonly.

Solid Tapped

256772_utility catalog.pdf 21 12/15/08 8:24:23 AM

Page 22: :DWHUZRUNV &DWDORJ - McWane

22

ANSI/AWWAC110/A21.10,ANSI/AWWAC111/A21.11

Gland Weight Size Wt.Pack GlandOnly

2 5 3 3 7 4 4 10 6 6 16 10 8 25 16 10 30 19 12 40 26 14 45 34 16 55 54 18 65 52 20 85 73 24 105 91 30 220 90 36 301 127 42 Call 279 48 Call 341

MJ GLAND

DUCTILE IRON C110 FULL BODY MECHANICAL JOINT FITTINGS

MJxMJxSwivel

Dimensions Size X Y Weight

6 8.0 10.5 150 8x6 9.0 11.5 199 8 9.0 11.5 21010x6 11.0 13.5 26712x6 12.0 14.5 34616x6 15.0 17.5 61916x8 15.0 17.5 64930x6 18.0 24.5 2070

AllweightsshownincludetheSwivelGland

TEES

DUCTILE IRON RETAINER GLANDS

Pressure Gland PipeO.D. D.I.Pipe Noof Sizeof Rating, O.D. O.D. Wall Set Set Gland Weight Size psi B A Class Screws Screws Weight w/Acces.

3 350 7.69 3.96 50-56 4 Áx2 4 8 4 350 9.12 4.80 50-56 4 Áx2 5 11 6 350 11.12 6.90 50-56 6 Áx2 9 16 8 250 13.37 9.05 50-56 9 Áx2 13 21 10 250 15.62 11.10 50-56 12 Áx2 17 26 12 150 17.88 13.20 50-56 16 Áx2 20 28 14 250 20.25 15.30 53-56 20 Áx2½ 44 55 16 200 22.50 17.40 53-56 24 Áx2½ 54 64 18 200 24.75 19.50 53-56 24 Áx2½ 62 72 20 200 27.00 21.60 53-56 28 Áx3 76 91 24 150 31.50 25.80 53-56 32 Áx3 103 118*NotincludedinAWWAC110

MechanicalJointRetainerGlandsaredesignedtoprovideamethodforrestrain-ingmechanicaljointpipeand**fittingsandotherstandardizedmechanicaljointsagainstpossiblejointseparation,ruptureorblow-outcausedbyinternalwaterpres-sure. Thesetscrewsaresquare-headedwithTypeCknurledcuppoints,andareshippedalreadyassembledintheGlands.Theyaremanufacturedof4140gradealloysteel,andareheattreatedtoaRock-wall“C”45/53casehardness.Tee-headboltsandgasketsarenotincluded,butmaybeorderedseparately.Recommend-edtorqueforsetscrewsis75footpounds,andsetscrewsonoppositesidesoftheglandsshouldbetightenedalternately. Tee-headboltholesizeandspac-ingareequaltoMJGlandsasshowninAWWAC-111.StandardmechanicalJointgasketsasshowninC-111shouldbeused.**Note: Not recommended for use on plain end fittings

*SET-SCREW RETAINER GLAND Pipe Wall Thickness:Sizes3"-12"arerecommendedforductileironpipeclass50thru56.Sizes14"thru24"arerecommendedforductileironpipeclass53thru56.

SeeInstallationsInstructions........................................................ Page48

256772_utility catalog.pdf 22 12/15/08 8:24:24 AM

Page 23: :DWHUZRUNV &DWDORJ - McWane

23

ANSI/AWWAC110/A21.10,ANSI/AWWAC111/A21.11

NOTE:Whenorderingglandsseparately,(1)SpecifyTYLERUNION UPCode Number,(2)Description,and(3)Sizeoffittingtobejoined.

Swivel x Solid Adapter

Sizeby Wall LayingLength Thickness Weight*

4x13 .52 52 6x12 .55 84 6x18 .55 91 6x24 .55 105 6x36 .55 156 8x13 .60 126 12x13 .75 186

*WeightswithGland.

ADAPTERS

SwivelGlands**Size Weight 12 30**NotincludedinAWWAC110.

SWIVEL GLAND ASSEMBLYUsedwithswivelfittings,theTYLERUNION Swivelgland,withitsrotatingfeature,permitstheinstallertomeetanygraderequire-mentsregardlessofbolt-holealignment.Inaddition,thesystempermitsstiffconnectionswithoutbraces,blockingorstrapping.

ELLS

*90° Swivel x Swivel Ell(Not Included In AWWA C110)

Wall Dimensions Size Thickness A B C D E F R *Weight

6 .55 10.5 15.5 7.10 11.12 6.90 8.02 6.0 106 8 .60 11.5 16.5 9.20 13.37 9.05 10.17 7.0 156

*With2SwivelGlands

DUCTILE IRON C110 FULL BODY MECHANICAL JOINT ELLS, ADAPTERS

AND GLANDSFor Valve and Hydrant Connections

OtherSwivelHydrantFittings,Pages5,6and7.

256772_utility catalog.pdf 23 12/15/08 8:24:24 AM

Page 24: :DWHUZRUNV &DWDORJ - McWane

11910CR492•Tyler,Texas75706•(800)527-8478

UNION-TITE DUCTILE IRON C153 COMPACT FITTINGS

Sizes 4"-16" UL Listed for Fire Main Equipment

BELL DIMENSIONS IN INCHES FOR UNION-TITE FITTINGS

Pipe Size A B B.C. C D E

4 5.04 6.38 7.88 4.16 2.25 .35 6 7.14 8.52 10.50 4.29 2.25 .37 8 9.32 10.90 12.88 4.78 2.25 .3910 11.37 12.91 14.69 4.98 2.25 .4112 13.47 15.12 17.19 4.98 2.25 .4314 15.64 18.12 19.00 5.40 2.25 .5116 17.74 20.32 21.40 5.40 2.25 .5218 19.83 22.52 ... 5.40 2.25 .5920 21.94 24.29 ... 5.40 2.25 .6024 26.14 29.14 ... 5.65 2.50 .62

SAMPLE SPECIFICATIONS (Current ANSI/AWWA revisions apply) 4"through24"Push-OnjointductileironfittingsshallbeproducedinaccordancewithallapplicabletermsandprovisionsofANSI/AWWAC153/A21.53.Fittingsarecement-linedandseal-coatedinaccordancewithANSI/AWWAC104/A21.4.Jointsshallbeinaccordancewithmanufacturer's design withbellsocketsdesignedtoreceivepressurepipeO.D.'sasspecifiedinANSI/AWWAC151/A21.51andAWWAC900TABLE2.Theworkingpressureratingshallbe350PSI,exceptforwyesandflanged-branchfittings.NOTE:Fittingsarecement linedandsealcoatedinaccordancewithANSI/AWWAC104/A21.4,alsoavailablebareorepoxycoated.Doublecementlinedavailable.Allcoatedfittingsmeetrequirementsof NSF-61.

Thicknessesanddimensionsofbellsocketsandgasketsshallbeinaccordancewiththemanufacturer'sdesign.Gasketsshallbefurnishedbythemanufacturer.Workingpressuresapplytofittingsonlyanddonotapplytorestraininglugsorexternalrestrainingdevices. Installation of fittings shall be per AWWA C600-10.

NOTE: Standard restraining lugs are provided on sizes 4" through 16" ONLY. Restraining lugs are available on 18"-24" fittings provided sufficient time is available to make tooling adaptations.

EXCEPTIONS: Union-Tite fittings with flanged branches are rated for water pressure of 250 PSI but can be rated for 350 PSI with the use of an annular ring or comparable gasket. Wye fittings over 12" are not pressure rated, call Tyler Union for information.

ADVANTAGESANDFEATURES• Push-ongasketjointusesTYTON®orMcWane 350 Sure Stop®gaskets• ForusewithDuctileironpipe,C-900/905PVCpipe,and4"-12"pressureratedIPSdiameterPVCpipe (with transition gasket)• Deepstabjointdesignaccommodatestaperonplasticpipes• SlipjointinstallationeliminatesT-boltsandnuts (MJglandsnotneeded)

TYTON®is aregisteredtrademarkofU.S.PipeandFoundryCompany.

For Joint deflection, refer to Tyler Union product submittal 26U located on page 65 of this catalog. 24

Page 25: :DWHUZRUNV &DWDORJ - McWane

25

BENDS

90° (1/4) 45° (1/8) 22½° (1/16) 11¼° (1/32) UT x Flange Bends UT x Flange Bends UT x Flange Bends UT x Flange Bends

Dimensions Dimensions Dimensions Dimensions Size T A B R Weight A B R Weight A B R Weight A B R Weight

4 .35 4.5 6.5 3.87 31 2.0 4.0 3.31 21 1.50 3.5 4.38 25 1.25 3.30 6.77 24 6 .37 6.0 7.0 5.37 49 3.0 5.0 5.72 42 2.25 4.3 8.16 44 1.50 3.50 9.38 30 8 .39 7.0 9.0 6.37 74 3.5 5.5 6.93 60 2.50 4.5 9.40 64 1.75 3.75 11.48 6110 .41 9.0 10.0 8.36 130 4.5 6.5 9.34 93 3.00 5.3 13.17 90 2.00 4.00 13.95 8012 .43 10.0 12.0 9.36 158 5.5 7.5 11.75 122 3.50 5.5 14.42 112 2.25 4.30 16.50 9414 .51 12.0 15.5 10.98 231 5.5 8.5 10.85 162 3.75 6.8 13.82 174 2.60 5.75 14.26 17016 .52 13.0 16.5 12.00 233 6.0 9.5 12.02 275 4.00 7.5 14.97 228 2.60 6.10 15.23 228

90° (1/4) UT Bends 45° (1/8) UT Bends 22½° (1/16) UT Bends 11¼° (1/32) UT Bends

Dimensions Dimensions Dimensions Dimensions Size T A R Weight A R Weight A R Weight A R Weight

4 .35 4.5 3.87 24 2.0 3.31 26 1.50 4.38 18 1.25 6.77 18 6 .37 6.0 5.37 51 3.0 5.72 42 2.25 8.16 39 1.50 9.38 40 8 .39 7.0 6.37 80 3.5 6.93 66 2.50 9.40 64 1.75 11.48 6010 .41 9.0 8.36 121 4.5 9.34 101 3.00 13.17 67 2.00 13.95 7712 .43 10.0 9.36 151 5.5 11.75 128 3.50 14.42 111 2.25 16.50 9414 .51 12.0 10.98 254 5.5 10.85 143 3.75 13.82 162 2.60 14.26 11316 .52 13.0 12.00 328 6.0 12.02 225 4.00 14.97 195 2.60 15.23 17218 .59 15.5 14.00 482 6.5 12.36 209 7.50 30.19 209 3.00 60.94 20920 .60 17.0 15.50 340 7.0 13.59 397 8.50 35.19 414 3.50 71.07 26524 .62 17.0 15.59 674 7.5 14.69 492 9.00 37.69 596 ... ... ...

UNION-TITE DUCTILE IRON C153 COMPACT FITTINGS

Sizes 4"-16" UL Listed for Fire Main Equipment

256772_utility catalog.pdf 25 12/15/08 8:24:25 AM

Page 26: :DWHUZRUNV &DWDORJ - McWane

26

90° (1/4) 45° (1/8) 22½° (1/16) 11¼° (1/32) UT x PE Bends UT x PE Bends UT x PE Bends UT x PE Bends

Dimensions Dimensions Dimensions Dimensions Size T A B R Weight A B R Weight A B R Weight A B RWeight

4 .35 4.5 10.5 3.87 35 2.0 8.0 3.31 21 ... ... ... .. ... ... ... .. 6 .37 6.0 12.0 5.37 70 3.0 9.0 5.72 38 2.25 8.08 8.16 35 1.50 7.30 9.38 36 8 .39 ... ... ... .. 3.5 9.5 6.93 60 2.50 8.34 9.40 57 1.75 7.55 11.48 55

UT x UT x PE Tees

Size Dimensions Run Branch T T1 H J3 Weight

6 6 .37 .37 6.0 11.5 60 8 6 .39 .37 6.0 12.5 80 12 6 .43 .37 7.0 15.5 140

BENDS

UNION-TITE DUCTILE IRON C153 COMPACT FITTINGS

TEES

256772_utility catalog.pdf 26 12/15/08 8:24:25 AM

Page 27: :DWHUZRUNV &DWDORJ - McWane

27

UNION-TITE DUCTILE IRON C153 COMPACT FITTINGS

TEES

UTxUTTees UTxFlangeTees UTxSwivelTees

Dimensions Weights Size T T1 H J1 J2 J3 UTxUT UTxFlange UTxSwivel

4 .35 .35 4.5 4.5 6.5 ... 44 45 ... 6x4 .37 .35 5.0 6.0 8.0 ... 68 56 ... 6 .37 .37 6.0 6.0 8.0 9.5 69 71 65 8x4 .39 .35 5.0 7.0 9.0 ... 73 89 ... 8x6 .39 .37 6.0 7.0 9.0 10.5 96 101 100 8 .39 .39 7.0 7.0 9.0 10.5 116 117 110 10x4 .41 .35 6.0 9.0 11.0 ... 102 115 ... 10x6 .41 .37 7.0 9.0 11.0 12.5 113 128 130 10x8 .41 .39 8.0 9.0 11.0 12.5 145 145 156 10 .41 .41 9.0 9.0 11.0 ... 155 158 ... 12x4 .43 .35 6.0 10.0 12.0 ... 119 138 ... 12x6 .43 .37 7.0 10.0 12.0 13.5 141 148 162 12x8 .43 .39 8.0 10.0 12.0 13.5 177 170 158 12x10 .43 .41 9.0 10.0 12.0 ... 160 162 ... 12 .43 .43 10.0 10.0 12.0 ... 217 183 ... 14x6 .51 .44 6.5 10.5 12.5 14.0 176 212 202 14x10 .51 .46 8.5 10.5 12.5 ... 195 246 ... 14x12 .51 .47 9.5 10.5 12.5 ... 196 296 ... 14 .51 .51 10.5 10.5 14.0 ... 209 321 ... 16x6 .52 .45 6.5 11.5 13.5 15.0 266 160 229 16x8 .52 .46 7.5 11.5 13.5 15.0 292 270 292 16x10 .52 .47 8.5 11.5 13.5 ... 232 330 ... 16x12 .52 .48 9.5 11.5 13.5 ... 239 321 ... 16x14 .52 .51 10.5 11.5 15.0 ... 349 342 ... 16 .52 .52 11.5 11.5 15.0 ... 261 355 ... 18x6 .59 .44 6.5 12.5 14.5 16.13 348 301 348 18x8 .59 .45 7.5 12.5 14.5 16.13 325 319 324 18x10 .59 .47 8.5 12.5 14.5 ... 344 337 ... 18x14 .59 .56 10.5 12.5 16.0 ... 342 393 ... 18x16 .59 .57 11.5 12.5 16.0 ... 362 420 ... 20x6 .60 .44 7.0 14.0 16.0 17.5 355 341 400 20x10 .60 .47 9.0 14.0 16.0 ... 369 420 ... 20x14 .60 .56 11.0 14.0 17.5 ... 484 474 ... 20x16 .60 .57 12.0 14.0 17.5 ... 610 498 ... 20x18 .60 .59 13.0 14.0 17.5 ... 539 ... ... 24x6 .62 .44 7.0 16.0 18.0 19.5 385 512 525 24x10 .62 .47 9.0 16.0 18.0 ... 478 468 ... 24x12 .62 .49 10.0 16.0 18.0 ... 663 503 ... 24x14 .62 .56 11.0 16.0 19.5 ... 542 531 ... 24x16 .62 .57 12.0 16.0 19.5 ... 566 555 ... 24x18 .62 .59 13.0 16.0 ... ... 593 ... 24x20 .62 .60 15.0 17.0 ... ... 628 ... ... 24 .62 .62 17.0 17.0 ... ... 884 ... ...

256772_utility catalog.pdf 27 12/15/08 8:24:25 AM

Page 28: :DWHUZRUNV &DWDORJ - McWane

28

Solid Cap Solid Plug

UT x Tapped Tee/Crosses

Dimensions Size T MaxTap L Weight

4 .35 3.0 6.0 27 6 .37 3.5 6.0 38 8 .39 3.5 6.0 59 10 .41 3.5 6.0 72 12 .43 3.5 6.0 92

TAPPED TEE/CROSS

UT Caps and Plugs*

Dimensions Weights Size T1 T2 L Cap Plug

4 .48 .50 5.25 15 8 6 .48 .50 5.25 20 23 8 .51 .53 5.25 35 32 10 .53 .56 5.25 50 38 12 .55 .62 5.25 75 49*Restraininglugs(ears)available.

CAPS AND PLUGS

UT x UT Reducers UT x Flange Reducers

Dimensions Weights Size T T1 L G UTxUT UTxFlange

6x4 .37 .35 4.0 6.0 32 32 8x4 .39 .35 5.0 7.0 46 46 8x6 .39 .37 4.0 6.0 49 47 10x4 .41 .35 7.0 9.0 47 55 10x6 .41 .37 5.0 7.0 47 59 10x8 .41 .39 4.0 6.0 53 61 12x4 .43 .35 9.0 11.0 74 78 12x6 .43 .37 7.0 9.0 58 75 12x8 .43 .39 5.0 7.0 74 74 12x10 .43 .41 4.0 6.0 82 95 14x6 .51 .44 9.0 11.0 84 121 14x8 .51 .45 7.0 9.0 85 128 14x10 .51 .46 5.0 7.0 87 127 14x12 .51 .47 4.0 6.0 104 144 16x6 .52 .45 11.0 13.0 94 133 16x8 .52 .46 9.0 11.0 104 141 16x10 .52 .47 7.0 9.0 130 158 16x12 .52 .48 5.0 7.0 152 172 16x14 .52 .51 4.0 6.0 139 196 18x8 .59 .45 14.0 16.0 142 157 18x10 .59 .47 12.0 14.0 151 175 18x12 .59 .49 10.0 12.0 167 215 18x14 .59 .56 8.0 11.5 217 234 18x16 .59 .57 7.0 10.5 202 246 20x10 .60 .47 14.0 16.0 180 234 20x12 .60 .49 12.0 ... 205 ... 20x14 .60 .56 10.0 13.5 233 249 20x16 .60 .57 8.0 11.5 250 272 20x18 .60 .59 7.0 ... 248 ... 24x12 .62 .49 16.0 18.0 246 262 24x14 .62 .56 14.0 17.5 281 315 24x16 .62 .57 12.0 15.5 380 328 24x18 .62 .59 10.0 ... 390 ... 24x20 .62 .60 8.0 ... 421 ...

REDUCERS

UT x Flange Adaptor

Dimensions Size T L Weight

4 .35 6.0 28 6 .37 6.0 36 8 .39 6.0 54 10 .41 6.0 71 12 .43 6.0 102 14 .51 7.0 113 16 .52 7.0 115 20 .60 6.0 295

2" Tapt Cap 2" Tapt Plug

UNION-TITE DUCTILE IRON C153 COMPACT FITTINGS

256772_utility catalog.pdf 28 12/15/08 8:24:26 AM

Page 29: :DWHUZRUNV &DWDORJ - McWane

29

UNION-TITE DUCTILE IRON C153 COMPACT FITTINGS

UT Wyes

Dimensions Size T T1 P N Weights

8x4 .39 .35 13.5 0.0 89 10x4 .41 .35 15.0 0.0 141 10x6 .41 .37 16.0 1.0 151 10x8 .41 .39 17.0 2.5 175 10 .41 .41 18.0 4.0 200 12x4 .43 .35 16.5 0.0 178 12x6 .43 .37 18.5 1.5 201 12x8 .43 .39 18.5 1.5 224 12x10 .43 .41 20.0 3.0 240 12 .43 .43 20.0 5.0 289 14x6 .51 .44 19.5 0.0 236 14x8 .51 .45 21.0 1.5 255 14x10 .51 .46 22.5 3.0 325 14 .51 .51 25.0 6.0 475 16x6 .52 .45 21.0 0.0 281 16x8 .52 .46 22.5 0.5 304 16x12 .52 .48 25.0 3.5 346 16 .52 .52 28.0 6.5 380

WYES CROSSES

UT Crosses

Dimensions Size T1 H J Weights

6 .37 6.0 6.0 88 8x6 .37 6.0 7.0 117 8 .39 7.0 7.0 156 10x4 .35 6.0 9.0 116 12x8 .39 8.0 10.0 240 12 .43 10.0 10.0 241 14x6 .44 6.5 10.5 189 14x8 .45 7.5 10.5 204 14x10 .46 8.5 10.5 222 14x12 .47 9.5 10.5 239 14 .51 10.5 10.5 270 16x6 .45 6.5 11.5 234 16x8 .46 7.5 11.5 323 16x10 .47 8.5 11.5 268 16x12 .48 9.5 11.5 274 16x14 .51 10.5 11.5 322 16 .52 11.5 11.5 317

TYTON® JOINT IPS Transition and Regular Gasket

Dimensions Transition(IPS) Regular(Ductile) Size A B(±1%) B* C

4 5.74 4.18 4.68 1.00 6 7.86 6.31 6.73 1.10 8 10.15 8.32 8.85 1.29 10 12.10 10.30 10.87 1.36 12 14.31 12.70 12.95 1.45

TYTON® GASKETS

NOTICE:Weightspublishedinthiscatalogareforshippingpurposesonly.Actualweightsmayvarybecausesomefittingsareproducedinbothfoundries.AllfittingsaremadeintheUSAandmeettheAWWAstandardstowhichtheyaredesigned. Forweightsofspecificfittings,pleasecontactyour TylerUnion Waterworksrepresentative.

TYTON®isaregisteredtrademarkof U.S.PipeandFoundryCompany.

256772_utility catalog.pdf 29 12/15/08 8:24:26 AM

Page 30: :DWHUZRUNV &DWDORJ - McWane

30

DUCTILE IRON C110FLANGED FITTINGS

Sizes3"thru12"ULListedforFireMainEquipment

SAMPLE SPECIFICATION (Current ANSI/AWWA revisions apply)Flangedfittings,2"through48"shallbemanufacturedofductileIroninaccordancewithallapplicabletermsandprovisionsofstandardsANSI/AWWAC110/A21.10.FlangesurfacesshallbefacedanddrilledinaccordancewithANSIClass 125, B16.1.Allductileironflangedfittingsshallberatedforwaterpressureof250PSI.Flangedductile-ironfittingsin24-in.(610 mm)andsmallersizesmayberatedfor350psi(2,413kPa)withtheuseofspecialgaskets.NOTE:Fittingsarecement linedandsealcoatedinaccordancewithANSI/AWWAC104/A21.4. Fittings arealsoavailableprimecoated,bareorepoxycoated.All coated fittings meetrequirementsofNSF-61.Interiorsof fittings shallbelinedandsealcoatedinaccordancewithANSI/AWWA C104/A21.4. Cement mortorliningforductileironpipeandfittingsforpotable water unlessotherwisespecified.Installation of fittings shall be per AWWA C110.

FLANGE DETAILS

Nominal Dia.of FlangePipeSize Flange Bolt Thickness BoltHole Number BoltDia. Inch O.D. Circle T Diameter ofBolts andLengths

2 6 4.75 .62 .75 4 Áx2¼ 3 7.5 6 .75 .75 4 Áx2½ 4 9 7.5 .94 .75 8 Áx3 6 11 9.5 1.00 .875 8 ¾x3½ 8 13.5 11.75 1.12 .875 8 ¾x3½ 10 16 14.25 1.19 1.00 12 Âx4 12 19 17 1.25 1.00 12 Âx4 14 21 18.75 1.38 1.125 12 1x4½ 16 23.5 21.25 1.44 1.125 16 1x4½ 18 25 22.75 1.56 1.25 16 1¿x5 20 27.5 25 1.69 1.25 20 1¿x5 24 32 29.5 1.88 1.375 20 1¼x5½ 30 38.75 36 2.12 1.375 28 1¼x6½ 36 46 42.75 2.38 1.675 32 1½x7 42 53 49.50 2.62 1.625 36 1½x7½ 48 59.50 56.00 2.75 1.625 44 1½x8

NOTE:Noflangejointmaterialfurnished.

NOTE:Drillingtemplatesareinmultiplesoffour,sothatfittingsmaybemadetofaceinanyquarter.Boltholesshallstraddlethecenterline.

256772_utility catalog.pdf 30 12/15/08 8:24:26 AM

Page 31: :DWHUZRUNV &DWDORJ - McWane

31

90° Bends (1/4) 45° Bends (1/8) 221/2° Bends (1/16) 111/4° Bends (1/32)

Dimensions Dimensions Dimensions DimensionsSize R A Weight R A Weight R A Weight R A Weight

2 3.0 4.5 14 ... ... ... ... ... ... ... ... ... 3 4 5.5 26 3.62 3 20 7.56 3 22 15.25 3 20 4 4.5 6.5 44 4.81 4 36 10.06 4 35 20.31 4 40 6 6 8 67 7.25 5 57 15.06 5 64 30.5 5 56 8 7 9 115 8.44 5.5 105 17.62 5.5 90 35.5 5.5 9010 9 11 164 10.88 6.5 131 22.62 6.5 130 45.69 6.5 13012 10 12 236 13.25 7.5 196 27.67 7.5 194 55.81 7.5 19314 11.5 14 330 12.06 7.5 245 25.12 7.5 250 50.75 7.5 24516 12.5 15 478 13.25 8 315 27.62 8 315 55.81 8 31518 14 16.5 527 14.5 8.5 422 30.19 8.5 402 60.94 8.5 38520 15.5 18 878 16.88 9.5 485 35.19 9.5 505 71.06 9.5 50524 18.5 22 1085 18.12 11 730 37.69 11 528 76.12 11 76030 21.5 25 1755 27.75 15 1355 57.81 15 1385 116.75 15 139536 24.5 28 2135 35.00 18 1755 72.88 18 1790 147.25 18 1805 42 27.5 31 3055 42.25 21 2600 88.00 21 2665 177.69 21 268048 30.5 34 4095 49.50 24 3580 103.06 24 3665 208.12 24 3695

BENDSNote:BaseBendsareonpage33and34,reducingandlongradius90°bendsareonpage33.

DUCTILE IRON C110FLANGED FITTINGS

Sizes3"thru12"ULListedforFireMainEquipment

256772_utility catalog.pdf 31 12/15/08 8:24:26 AM

Page 32: :DWHUZRUNV &DWDORJ - McWane

32

DUCTILE IRON C110FLANGED FITTINGS

TEES, REDUCING TEES, CROSSES

Straight Tees, Reducing *Reducing *Reducing on *Bullhead Straight and on Branch Tees on Run Run and Branch Tees Reducing Crosses

Size Dimensions Weights Run Run Branch H J Tee Cross

2 2 2 4.5 4.5 20 3 3 2 5.5 5.5 35 ... 3 3 3 5.5 5.5 42 51 4 3 3 6.5 5.5 53 ... *4 4 2 6.5 6.5 55 ... 4 4 3 6.5 6.5 54 76 4 4 4 6.5 6.5 60 87 *4 4 6 8.0 8.0 88 ... *6 4 4 8.0 8.0 96 ... *6 4 6 8.0 8.0 100 ... *6 6 2 8.0 8.0 85 ... 6 6 3 8.0 8.0 85 96 6 6 4 8.0 8.0 90 112 6 6 6 8.0 8.0 98 141 6 6 8 9.0 9.0 138 ... *8 6 4 9.0 9.0 130 ... *8 6 6 9.0 9.0 148 ... *8 6 8 9.0 9.0 154 ... 8 8 3 9.0 9.0 128 140 8 8 4 9.0 9.0 155 155 8 8 6 9.0 9.0 148 172 8 8 8 9.0 9.0 179 195 *8 8 10 11.0 11.0 225 ... *8 8 12 12.0 12.0 277 ...*†10 6 6 13.0 13.0 278 ...*†10 6 10 13.0 13.0 308 ...*†10 8 6 13.0 13.0 298 ...*†10 8 8 13.0 13.0 278 ...*†10 8 10 13.0 13.0 325 ... 10 10 4 11.0 11.0 239 220 10 10 6 11.0 11.0 215 242 10 10 8 11.0 11.0 254 294 10 10 10 11.0 11.0 265 330 10 10 12 12.0 12.0 337 ...*†12 6 6 14.0 14.0 346 ...*†12 6 8 14.0 14.0 362 ...*†12 8 6 14.0 14.0 355 ...

Size Dimensions Weights Run Run Branch H J Tee Cross

*12 8 8 12.0 12.0 375 ...*12 8 12 12.0 12.0 420 ...*†12 10 6 14.0 14.0 390 ... 12 10 8 12.0 12.0 400 ... 12 10 10 12.0 12.0 420 ... 12 10 12 12.0 12.0 440 ... 12 12 4 12.0 12.0 322 310 12 12 6 12.0 12.0 297 326 12 12 8 12.0 12.0 346 351 12 12 10 12.0 12.0 394 415 12 12 12 12.0 12.0 369 438*14 14 4 14.0 14.0 410 ... 14 14 6 14.0 14.0 420 450 14 14 8 14.0 14.0 435 475 14 14 10 14.0 14.0 450 ... 14 14 12 14.0 14.0 470 555 14 14 14 14.0 14.0 500 595*16 16 4 15.0 15.0 525 ... 16 16 6 15.0 15.0 573 565 16 16 8 15.0 15.0 555 590 16 16 10 15.0 15.0 565 620 16 16 12 15.0 15.0 590 665 16 16 14 15.0 15.0 610 ... 16 16 16 15.0 15.0 635 755 18 18 6 13.0 15.5 780 ... 18 18 8 13.0 15.5 609 ... 18 18 10 13.0 15.5 585 ... 18 18 12 13.0 15.5 638 706 18 18 14 16.5 16.5 808 ... 18 18 16 16.5 16.5 760 ... 18 18 18 16.5 16.5 865 915

* NotincludedinAWWAC110 † HandJdimensionsaretwo-incheslongerthanstraight tees.

256772_utility catalog.pdf 32 12/15/08 8:24:27 AM

Page 33: :DWHUZRUNV &DWDORJ - McWane

33

TEES, REDUCING TEES, CROSSES (Con't)

Size Dimensions Weights Run Run Branch H J Tee Cross

20 20 6 14.0 17.0 773 ... 20 20 8 14.0 17.0 720 ... 20 20 10 14.0 17.0 735 ... 20 20 12 14.0 17.0 816 820 20 20 14 14.0 17.0 770 ... 20 20 16 18.0 18.0 950 1065 20 20 18 18.0 18.0 965 ... 20 20 20 18.0 18.0 1005 1175 24 24 6 15.0 19.0 1089 ... 24 24 8 15.0 19.0 1060 ... 24 24 10 15.0 19.0 1020 ... 24 24 12 15.0 19.0 1125 1100 24 24 14 15.0 19.0 1050 1125 24 24 16 15.0 19.0 1070 1160 24 24 18 22.0 22.0 1534 ... 24 24 20 22.0 22.0 1510 1695 24 24 24 22.0 22.0 1685 1850*30 30 6 18.0 23.0 1725 ... 30 30 12 18.0 23.0 1801 ... 30 30 18 18.0 23.0 1852 ... 30 30 24 25.0 25.0 2475 2695 30 30 30 25.0 25.0 2615 2985 36 36 24 20.0 26.0 2255 ... 36 36 30 28.0 28.0 3000 ... 36 36 36 28.0 28.0 3160 6740 42 42 24 23.0 30.0 3245 ... 42 42 30 31.0 31.0 4125 ... 42 42 36 31.0 31.0 5360 ... 42 42 42 31.0 31.0 5580 ... 48 48 24 28.0 34.0 4385 ... 48 48 30 26.0 34.0 4455 ... 48 48 36 34.0 34.0 5555 ... 48 48 42 34.0 34.0 7195 ... 48 48 48 34.0 34.0 7385 ...

*NotincludedinAWWAC110

*Flange and Flare 90° Ell

DimensionsSize D X Y Weight

3 7.5 5.5 8.5 26 4 9.0 6.5 9.5 39 6 11.0 8.0 12.0 73 8 13.5 9.0 13.0 11010 16.0 11.0 15.0 17112 19.0 12.0 16.0 25314 21.0 14.0 22.0 45016 23.5 15.0 23.0 54518 25.0 16.5 24.5 67520 27.5 18.0 26.0 86024 32.0 22.0 30.0 1195

*NotincludedinAWWAC110

FLANGE AND FLARE

*Flange and Flare Piece

Dimensions Size D L Weight

3 7.25 8 21 4 9.00 8 30 6 11.00 8 44 8 13.50 10 7510 16.00 10 11312 19.00 12 15514 21.00 16 22516 23.50 16 33018 25.00 16 35520 27.50 18 46524 32.00 18 598

DUCTILE IRON C110FLANGED FITTINGS

256772_utility catalog.pdf 33 12/15/08 8:24:27 AM

Page 34: :DWHUZRUNV &DWDORJ - McWane

DUCTILE IRON C110FLANGED FITTINGS

REDUCERS

Concentric Reducer Eccentric Reducer

NOTE: Eccentric Reducers not included in AWWA C110

NOTE: Eccentric Reducers Offset1/2 D minus 1/2 D1=OffsetExample:6x3 Ecc.Reducer3-1½ = 1½" Offset

Size Dimensions Wts D D1 L

3 2 6 17 4 2 7 23 4 3 7 29 6 2 9 30 6 3 9 44 6 4 9 46 6 5 9 56 8 3 11 61 8 4 11 63 8 5 11 70 8 6 11 75 10 4 12 98 10 6 12 107 10 8 12 116 12 4 14 119 12 6 14 130 12 8 14 152 12 10 14 178 14 6 16 165 14 8 16 185 14 10 16 205 14 12 16 235 16 6 18 210 16 8 18 230 16 10 18 255 16 12 18 285 16 14 18 315

Size Dimensions Wts D D1 L

4 3 7 30 6 3 9 45 6 4 9 52 8 4 11 70 8 6 11 80 10 4 12 95 10 6 12 98 10 8 12 123 12 4 14 120 12 6 14 135 12 8 14 149 12 10 14 177 14 6 16 165 14 8 16 185 14 10 16 205 14 12 16 294 16 6 18 210 16 8 18 230 16 10 18 255 16 12 18 285 16 14 18 315 18 8 19 265 18 10 19 290 18 12 19 306

Size Dimensions Wts D D1 L

18 8 19 265 18 10 19 290 18 12 19 320 18 14 19 350 18 16 19 405 20 10 20 418 20 12 20 465 20 14 20 430 20 16 20 445 20 18 20 470 24 12 24 608 24 14 24 565 24 16 24 610 24 18 24 645 24 20 24 695 30 16 30 945 30 18 30 970 30 20 30 1144 30 24 30 1155 42 24 42 1810 42 30 42 2060 42 36 42 2345 48 30 48 2615 48 36 48 2940 48 42 48 3320

Size Dimensions Wts D D1 L

18 14 19 350 18 16 19 385 20 10 20 350 20 12 20 370 20 14 20 402 20 16 20 449 20 18 20 455 24 12 24 535 24 14 24 570 24 16 24 614 24 18 24 645 24 20 24 695 30 16 30 778 30 18 30 810 30 20 30 870 30 24 30 970 36 24 36 1425 36 30 36 1555 42 24 42 1820 42 30 42 2060 42 36 42 2345 48 30 48 2625 48 36 48 2950 48 42 48 3320

34

Page 35: :DWHUZRUNV &DWDORJ - McWane

35

BASE BENDS, BASE TEES

BaseBendsaremadetoorderonly,notreturnable.Basesarefurnishedfacedanddrilled.

DUCTILE IRON C110FLANGED FITTINGS

90° Base Bend (1/4) *90° Long Radius Base Bend (1/4) Base Tees

*90° Long Radius Bend (1/4)

Dimensions Size R A Weight

3 6.25 7.75 32 4 7 9 46 6 9.5 11.5 83 8 14 14 140 10 16.5 16.5 252 12 17 19 310 14 19 21.5 475 16 21.5 24 630

*90° Reducing Bend (1/4)

Dimensions Size A Weight

4x3 6.5 35 6x4 8.0 65 8x4 9.0 88 8x6 9.0 96

10x8 10.0 151 12x6 12.0 17212x8 12.0 191

12.0 5.5 315 12x10 12.0 218 18 ..... 26.5 840 14x6 14.0 230 20 ..... 29 1080 14x8 14.0 240 24 ..... 34 1640

*Notincludedin AWWA C110

* WYES/LATERALS BENDS

Support Dimensions Pipe Weight Size X S U Size 90° 90°LR Tee

3 4.88 5 .50 1.5 38 41 47 4 5.50 6 .50 2.0 50 60 76 6 7.00 7 .62 2.5 83 100 115 8 8.38 9 .88 4.0 142 180 195 10 9.75 9 .88 4.0 210 315 315 12 11.25 11 1.00 6.0 300 427 450 14 12.50 11 1.00 6.0 400 580 570 16 13.75 11 1.00 6.0 505 740 710 18 15.00 13.5 1.12 8.0 645 ... 900 20 16.00 13.5 1.12 8.0 805 ... 1125 24 18.50 13.5 1.12 8.0 1215 ... 1927 30 23.00 16 1.15 10.0 1945 ... ... 36 26.00 19 1.15 10.0 2395 2895 ... *NotincludedinAWWAC110

*45° Wye

Size Dimensions Run Branch H J Weight

3 3 10 3 49 4 3 12 3 68 4 4 12 3 76 6 4 14.5 3.5 106 6 6 14.5 3.5 131 8 4 17.5 4.5 153 8 6 17.5 4.5 188 8 8 17.5 4.5 201 10 4 20.5 5 232 10 6 20.5 5 288 10 8 20.5 5 333 10 10 20.5 5 300 12 4 24.5 5.5 355 12 6 24.5 5.5 370 12 8 24.5 5.5 395 12 10 24.5 5.5 420 12 12 24.5 5.5 460 14 6 27 6 500 14 8 27 6 525 14 10 27 6 555 14 12 27 6 600 14 14 27 6 640 16 6 30 6.5 655 16 8 30 6.5 680 16 10 30 6.5 715 16 12 30 6.5 755 16 14 30 6.5 800 16 16 30 6.5 850 18 8 32 7 820 18 10 32 7 855 18 12 32 7 100318 14 32 7 940 18 16 32 7 990 18 18 32 7 103520 10 35 8 109520 12 35 8 113020 14 35 8 117020 16 35 8 122020 20 35 8 134524 24 40.5 9 2020 36 36 60 19.5 5740 *NotincludedinAWWAC110

True Wye

Size Dimensions Stem Branch X Y Weight

4 4 6.5 3.0 496 4 8.0 3.5 756 6 8.0 3.5 848 6 9.0 4.5 1348 8 9.0 4.5 12510 6 8.0 5.0 140 10x6 11.0 126 10 8 9.0 5.0 15510 10 11.0 5.0 220 12 8 9.0 5.5 210 12 10 11.0 5.5 240 12 12 16 16 15.0 6.5 520*NotincludedinAWWAC110

256772_utility catalog.pdf 35 12/15/08 8:24:27 AM

Page 36: :DWHUZRUNV &DWDORJ - McWane

36

DUCTILE IRON C110FLANGED FITTINGS

* FLANGE SLUDGE SHOE

FLANGES (COMPANION FLG)

FlangeforDIPipeReducingFlangeforDIPipe

FlangeforSteelPipeReducingFlangeforSteelPipe

Dimensions Weight Size O Q Y Z Steel DI Blind BlindTap

2 6 .62 1 4.75 4 ... ... ... 2½ 7 .69 1.13 5.50 8 ... ... ... 3 7.5 .75 1.19 6.00 7 6 8 8 4 9 .94 1.31 7.50 12 11 15 15 6 11 1.00 1.56 9.50 21 14 28 28 8 13.5 1.12 1.75 11.75 28 34 45 45 10 16 1.19 1.94 14.25 49 33 62 62 12 19 1.25 2.19 ... 61 52 72 87 14 21 1.38 2.25 ... ... 72 110 110 16 23.5 1.44 2.50 ... ... 90 165 165 18 25 1.56 2.69 ... ... 105 192 190 20 27.5 1.69 2.88 ... ... 115 249 250 24 32 1.88 3.25 ... ... 160 375 370 30 38.75 2.12 ... ... ... 255 580 580 36 46.00 2.38 ... ... ... ... 790 ... 42 53.00 2.62 ... ... ... ... 1175 ... 48 59.50 2.75 ... ... ... ... 1585 ...NOTE: AllflangesconformtoANSI/AWWAC110/A21.10Standards.

Under12"BlindFlangeWithOptional2"Taps

12"andLargerBlindFlangeWithOptional2"Taps

DI Reducing Flange DI Reducing Flange Threaded For Steel Pipe Threaded For Cast Iron Pipe

Size TapxO.D. Weight Size TapxO.D. Weight

4x3 3x9 16 4x3 3x9 16 6x4 4x11 25 6x4 4x11 25 8x4 4x13½ 44 8x4 4x13½ 40 8x6 6x13½ 31 8x6 6x13½ 35 10x6 6x16 50 10x8 8x16 50 12x6 6x19 60 12x8 8x19 85 10x8 8x16 55 12x10 10x19 72

Flange Sludge Shoe

DimensionsSize D X Y Weight

3 5.75 12 6 28 4 7.00 12 6 35 6 7.87 12 6 45 8 10.12 12 6 6910 12.25 12 6 8812 15.25 12 6 120*NotincludedinAWWAC110

* REDUCING BASE BENDS

Base Under Base Under Large End Small End

Dimensions Size X S U Weight

4x3 5.5 6 .50 45 6x4 7 7 .62 75 8x4 8.38 9 .88 118 8x6 8.38 9 .88 135 10x6 9.75 9 .88 175 10x8 9.75 9 .88 184 12x6 11.25 11 1.00 230 12x8 11.25 11 1.00 255 12x10 11.25 11 1.00 285*NotincludedinAWWAC110NOTE:“X”dimensionsareidenticalonBase-under-large-endandBase-under-small-end.“S”dimensionsaredeterminedbythelargestfittingopening.

Base Drilling Details

Nom. Dimensions-Inches Diameter BoltHole Number Inches BC Diameter ofBolts

3 3.88 5/8 4 4 4.75 3/4 4 6 5.50 3/4 4 8 7.50 3/4 4 10 7.50 3/4 4 12 9.50 7/8 4 14 9.50 7/8 4 16 9.50 7/8 4 18 11.75 7/8 4 20 11.75 7/8 4 24 11.75 7/8 4 30 14.25 1 4 36 17.00 1 4 42 21.25 1-1/8 4 48 22.75 1-1/4 4

(IfRequired)

256772_utility catalog.pdf 36 12/15/08 8:24:28 AM

Page 37: :DWHUZRUNV &DWDORJ - McWane

37

DUCTILE IRON C110FLANGED FITTINGS

Fitting Size Maximum Tap Without Boss

3".......................1/2" 4"-6"................3/4" 8".......................1-1/4" 10"-16"..............1-1/2" 18"-36"..............2"

**LOCATION OF TAPPED HOLES FOR DRAINS AWWA C110 Flanged FittingsFittingscanbesuppliedwithtapssizedandlocatedtoANSIB16.1andMSS-SP-45.Specifyfittingsize,taplocationbyletter(refertodrawings)andtapsizebyNPTdimension,onorder.

ADDER for Tapping & Extra Heavy 250 Class Flange Policy:For pricing oftapped outlets, tapped for studs, and extra heavy 250 ClassC-110Flangedfittingsrefer to List Price Guide or consultyourTyler Union Inside SalesRepresentativeforcurrentpricing and more details. **NOTE: For additional tapping options contact the Tyler Union Waterworks Inside Sales Representative for your State.

DUCTILE IRON ADAPTER FLANGE

DuctileIron D F C PipeOD +.06 +.07Size +.06or-.06 -.04 -.03 Weight

3 3.96 4.94 4.06 .94 7 4 4.80 6.02 4.90 1.00 10 6 6.90 8.12 7.00 1.06 14 8 9.05 10.27 9.15 1.12 2210 11.10 12.34 11.20 1.19 3012 13.20 14.44 13.30 1.25 40

Allsetscrewsare5/8"80lb.torquehead.

WallThicknessNote:RecommendedforDuctileIronPipeClass53thruClass56.

Rated No.of No.of Bolt Working Set Bolt Bolt& Size HoleSize Pressure Screws Circle Nuts ofBolt Dia.

3 250 4 6.00 4 Áx2½ ¾ 4 250 4 7.50 8 Áx3 ¾ 6 250 8 9.50 8 ¾x3½ Â 8 250 8 11.75 8 ¾x3½ Â10 250 12 14.25 12 Âx4 112 150 12 17.00 12 Âx4 1

SeeIndexforInstallationInstructions

FittingSizeMaximumTap Fitting Maximum Tap Size Without Boss

NOTE: A BOSS IS ALWAYS REqUIRED AT “Y” OR “V” ON STRAIGHT AND REDUCING SIzES OF 90-DEGREE ELBOWS, AND ON TAPERED SIDES OF REDUCERS.

ADAPTER FLANGES(Ez OR UNI)

256772_utility catalog.pdf 37 12/15/08 8:24:28 AM

Page 38: :DWHUZRUNV &DWDORJ - McWane

38

CAST IRON SERVICE BOXES, ADJUSTABLEAccommodates 2" through 1¼" curbstops; enlarged base

Accommodates 2" curbstops; 2½" shaft - screw type

6500 SERIES PARTS

UPCode ShipItem 67610 Code Wt.

151Ext 144762 S 7.0152Ext 144779 5 12.0153Ext 144786 S 17.0154Ext 144793 S 19.0EnlargedBase 144809 S 8.02½"“WaterLid” 144830 S 1.0BrassScrew(Std.WWPentagon) 144816 S ...Wrench(Std.WWPentagon) 144908 S 0.52½"“RepairLidOld” 144915 S 4.52½"“RepairLidNew” 144922 S 4.52½"“RepairLidOutsideCover” 381518 S 4.5

6500 SERIES, SCREW TYPE WITH WATER LID

UPCode Ship ExtensionBox(Compoents) 67610 Code InInches Weight

89-A(12T&12B) 146681 S 15-21 2090-B(12T&15B) 146742 S 18-24 2190-C(15T&15B) 146803 S 21-27 2291-C(15T&21B) 146865 S 24-33 2492-C(15T&27B) 146926 S 30-39 2692-D(18T&27B) 146988 S 30-42 2893-D(18T&33B) 147046 S 36-48 3293-E(24T&33B) 147114 S 36-54 3794-E(24T&39B) 147183 S 42-60 4195-E(30T&39B) 147251 S 41-64 44100-E(24T&21B&#154Ext) 147312 S 54-72 50100-F(30T&21B&#154Ext) 147381 S 54-78 53101-F(30T&27B&#154Ext) 147459 S 60-84 55

TOP SECTION WITH WATER LID

UPCode ShipItem 67610 Code Weight

12T 147510 S 1115T 147589 S 1218T 147640 S 1424T 147701 S 1930T 147763 S 22

BOTTOM ONLY

UPCode ShipItem 67610 Code Weight

12B 144670 S 915B 144687 S 1021B 144694 S 1227B 144700 S 1433B 144717 S 1839B 144724 S 22

EXTENSION

HeightItem Increase

151 9152 16153 28154 30

ENLARGED BASEFor 2" Curbstop HeightItem Increase

6500 6"

Lid

Top

Bottom

(New Style)Repair Lid

(Old Style)Repair Lid

Wrench

Brass ScrewStd. WW Pentagon

Box Assembled

(Outside Cover)Repair Lid

256772_utility catalog.pdf 38 12/15/08 8:24:28 AM

Page 39: :DWHUZRUNV &DWDORJ - McWane

TYLER UNION valve boxes are available either pre-assembled or as individual tops and bottoms. For assembled boxes, The UPC codes shown represent a combination of one top and one bottom in the sizes shown. For unassembled boxes, the UPC code represents only a top or a bottom, not a complete box. Therefore, unassembled boxes require ordering tops and bottoms separately.

**NOTE: Domestic Valve Boxes available in Heavy Duty Only Non-Domestic available in Standard or Heavy Duty

**6850 SERIESCAST IRON TWO-PIECE VALVE BOXES

for 4" through 12" valves, 51/4" shaft, screw-type

Extension *(D-HD)UPCode *(ND-HD)UPCode *(ND-Std.)UPCodeBox (Components) Height 670610 670610 Wt 670610 Wt

461-S (10T + 15B) 19-22 145776 502098 50 112280 35462-S (10T + 24B) 27-32 145783 502104 58 112297 43562-S (16T + 24B) 27-37 145790 502111 71 112303 50563-S (16T + 30B) 33-43 145752 ----- 78 112310 60564-S (16T + 36B) 39-50 145806 502128 85 112327 66662-S (26T + 30B) 36-52 145769 ---- 93 112341 76664-S (26T + 36B) 39-60 145813 ---- 100 112358 82665-S (26T + 24B) 39-63 375296 ---- 87 --- ---666-S (26T+24B+60 Ext) 51-71 145820 502135 128 112365 95668-S (26T+36B+60 Ext) 62-82 145837 ---- 136 112372 111NOTE: D=Domestic ND=Non-Domestic HD=Heavy Duty Weight Std.=Standard Weight

Box Assembled(Less Lid)

Lids marked “WATER” will ship unless otherwise specified: Also available 5¼" Drop Lids"1)WATER OMA 2)SEWER 3)MWW 4)PLAIN 5)GAS 6)REUSENote: Special Lettering Available Contact Tyler Union for Setup Charge

39

Page 40: :DWHUZRUNV &DWDORJ - McWane

SEPARATE UPCODES for VALVE BOX TOPS ONLY (Less Lids) TOP **(D-HD)UPCode **(ND-HD)UPCode **(ND-Std.)UPCodeBox Length 670610 Wt 670610 Wt 670610 Wt

461-S (10T) 144939 22 502142 22 112402 15462-S (10T) 144939 22 502142 22 112402 15562-S (16T) 144946 36 502159 36 112419 22563-S (16T) 144946 36 502159 36 112419 22564-S (16T) 144946 36 502159 36 112419 22662-S (26T) 144953 51 502166 51 112426 38664-S (26T) 144953 51 502166 51 112426 38666-S (26T) 144953 51 502166 51 112426 38668-S (26T) 144953 51 502166 51 112426 38

**NOTE:D=Domestic ND=Non-Domestic HD=HeavyDutyWeight Std.=StandardWeight

SEPARATE UPCODES for VALVE BOX BOTTOMS ONLY

Bottom **(D-HD)UPCode **(ND-HD)UPCode **(ND-Std.)UPCodeBox Length 670610 Wt 670610 Wt 670610 Wt

461-S (15B) 145004 27 502173 27 112242 20462-S (24B) 145011 35 502180 35 112259 28562-S (24B) 145011 35 502180 35 112259 28563-S (30B) 144991 42 502197 42 112266 38564-S (36B) 145028 49 502203 49 112273 44662-S (30B) 144991 42 502197 42 112266 38664-S (36B) 145028 49 502203 49 112273 44666-S (24B) 145011 35 502180 35 112259 28668-S (36B) 145028 49 502203 49 112273 44 (48B) --- --- --- --- 452737 62 (60B) --- --- --- --- 452744 85 **Note: D=Domestic ND=Non-Domestic HD=Heavy Duty Weight Std.=Standard Weight

6850 SERIESCAST IRON TWO-PIECE VALVE BOXES

for 4" through 12" valves, 51/4" shaft, screw-type

60 Extension

58 and 59 Extension

EXTENSIONS Height **(D-HD)UPCode **(ND-Std.)UPCodeItem/Description Increase 670610 Wt 670610 Wt

#58Screw-Type 14 145141 29 --- ---#59Screw-Type 18 145158 30 --- ---#60Screw-Type 24 145059 37 112389 29

40

Page 41: :DWHUZRUNV &DWDORJ - McWane

6855 SERIESCAST IRON TWO-PIECE VALVE BOXES

for 4" through 12" valves, 51/4" shaft, slip-type

Box Assembled(Less Lid)

TYLER UNION valve boxes are available either pre-assembled or as individual tops and bottoms. For assembled boxes, The UPC codes shown represent a combination of one top and one bottom in the sizes shown. For unassembled boxes, the UPC code represents only a top or a bottom, not a complete box. Therefore, unassembled boxes require ordering tops and bottoms separately.

**NOTE: Domestic Valve Boxes available in Heavy Duty Only Non-Domestic available in Standard or Heavy Duty

Extension *(D-HD)UPCode *(ND-HD)UPCode *(ND-Std.)UPCodeBox (Components) Height 670610 670610 Wt 670610 Wt

461-A (10T + 15B) 19-22 145844 502234 55 112099 34462-A (10T + 24B) 27-32 145831 ---- 65 112105 46562-A (16T + 24B) 27-37 145868 502241 72 112112 55563-A (16T + 30B) 33-43 145714 ---- 81 112129 67564-A (16T + 36B) 39-50 145875 502258 83 112136 72662-A (26T + 30B) 36-52 145721 ---- 97 112143 83664-A (26T + 36B) 39-60 145882 502265 99 112150 88666-A (26T+24B+60 Ext) 51-71 145899 ---- 124 112167 108668-A (26T+36B+60 Ext) 62-82 145905 ---- 135 112181 125NOTE: D=Domestic ND=Non-Domestic HD=Heavy Duty Weight Std=Standard Weight

Lids marked “WATER” will ship unless otherwise specified: Also available 5¼" Drop Lids"1)WATER OMA 2)SEWER 3)MWW 4)PLAIN 5)GAS 6)REUSENote: Special Lettering Available Contact Tyler Union for Setup Charge

41

Page 42: :DWHUZRUNV &DWDORJ - McWane

SEPARATE UPCODES for VALVE BOX BOTTOMS ONLY

Bottom **(D-HD)UPCode **(ND-HD)UPCode **(ND-Std.)UPCodeBox Length 670610 Wt 670610 Wt 670610 Wt

461-A (15B) 145073 26 502302 26 112051 20462-A (24B) 145080 36 502319 36 112068 30562-A (24B) 145080 36 502319 36 112068 30563-A (30B) 145127 45 502333 45 112075 39564-A (36B) 145097 47 502340 47 112082 43662-A (30B) 145127 45 502333 45 112075 39664-A (36B) 145097 47 502340 47 112082 43666-A (24B) *145080 36 *502319 36 *112068 30668-A (36B) *145097 47 *502240 47 *112082 43 (60B) --- --- --- --- 458302 75

**NOTE: D=Domestic ND=Non-Domestic HD=Heavy Duty Weight Std=Standard Weight

*NOTE: Whe installing thes extensions a 6850 screw type bottom is required

6855 SERIESCAST IRON TWO-PIECE VALVE BOXES

for 4" through 12" valves, 51/4" shaft, slip-type

60-A Extension

58-A and 59-A Extension

SEPARATE UPCODES for VALVE BOX TOPS ONLY (Less Lids) TOP **(D-HD)UPCode **(ND-HD)UPCode **(ND-Std.)UPCodeBox Length 670610 Wt 670610 Wt 670610 Wt

461-A (10T) 144960 29 502272 29 112211 15462-A (10T) 144960 29 502272 29 112211 15562-A (16T) 144977 36 502289 36 112228 25563-A (16T) 144977 36 502289 36 112228 25564-A (16T) 144977 36 502289 36 112228 25662-A (26T) 144984 52 502296 52 112235 38664-A (26T) 144984 52 502296 52 112235 38666-A (26T) 144984 52 502296 52 112235 38668-A (26T) 144984 52 502296 52 112235 38

**NOTE:D=Domestic ND=Non-Domestic HD=HeavyDutyWeight Std=StandardWeight

EXTENSIONS Height **(D-HD)UPCode **(ND-Std.)UPCodeItem/Description Increase 670610 Wt 670610 Wt

#58-ASlip-Type 6to14 145233 29 136637 26#59-ASlip-Type 6to18 145240 30 136644 28#60-ASlip-Type 6to24 145066 36 112198 37

42

Page 43: :DWHUZRUNV &DWDORJ - McWane

6860 SERIESCAST IRON THREE-PIECE VALVE BOXES

for 3" through 20" valves, 51/4" shaft, screw-type***(Base required, order separately)

Box Assembled (Less Lid)

Base IllustratedFor Position Only...

Not Furnished.

TYLER UNION valve boxes are available either pre-assembled or as individual tops and bottoms. For assembled boxes, The UPC codes shown represent a combination of one top and one bottom in the sizes shown. For unassembled boxes, the UPC code represents only a top or a bottom, not a complete box. Therefore, unassembled boxes require ordering tops and bottoms separately.

**NOTE: Domestic Valve Boxes available in Heavy Duty Only Non-Domestic available in Standard or Heavy Duty

Extension *(D-HD)UPCode *(ND-HD)UPCode *(ND-Std.)UPCodeBox (Components) Height 670610 670610 Wt 670610 Wt

AA (10T + 12B) 27-37 145912 ---- 42 136668 29A (16T + 18B) 33-42 145929 ---- 65 136651 38B (16T + 24B) 39-49 145936 ---- 69 136675 51C (16T + 30B) 45-54 145943 ---- 73 136682 55CC (16T + 36B) 51-60 145950 ---- 75 136699 59D (26T + 30B) 45-66 145967 502357 88 136811 71DD (26T + 36B) 51-72 145974 502364 90 136828 75E (16T+24B+60 Ext) 63-72 145981 ---- 105 136835 80F (26T+24B+60 Ext) 63-84 145998 ---- 120 136842 96G (26T+36B+60 Ext) 74-94 146001 502371 126 136859 104

*NOTE: D=Domestic ND=Non-Domestic HD=Heavy Duty Weight Std=Standard Weight***NOTE: Base Selection Guide (#4 Base for 6” valves or less) (#6 Base for 12” valves or less) (#160 Base for 24” valves or less)

Lids marked “WATER” will ship unless otherwise specified: Also available 5¼" Drop Lids"1)WATER OMA 2)SEWER 3)MWW 4)PLAIN 5)GAS 6)REUSENote: Special Lettering Available Contact Tyler Union for Setup Charge

43

Page 44: :DWHUZRUNV &DWDORJ - McWane

6860 SERIESCAST IRON THREE-PIECE VALVE BOXES

for 3" through 20" valves, 51/4" shaft, screw-type(Base required, order separately)

EXTENSIONS UPCode HeightItem/Description 670610 Increase Wt

#58Screw-Type 145141 14 29#59Screw-Type 145158 18 30#60Screw-Type 145059 24 37#60Screw-Type *112389 24 29#60Screw-Type *Call 24 36*Non-Domestic

#4 Base #6 Base(Standard)

#160 Base60 Extension58 and 59 Extension

SEPARATE UPCODES for VALVE BOX TOPS ONLY (Less Lids) TOP **(D-HD)UPCode **(ND-HD)UPCode **(ND-Std.)UPCodeBox Length 670610 Wt 670610 Wt 670610 Wt

AA (10T) 144939 23 502142 23 112402 15A (10T) 144939 23 502142 23 112402 15B (16T) 144946 36 502159 36 112419 22C (16T) 144946 36 502159 36 112419 22CC (16T) 144946 36 502159 36 112419 22D (26T) 144953 51 502166 52 112426 38DD (26T) 144953 51 502166 52 112426 38E (16T) 144946 36 502159 36 112419 22F (26T) 144953 51 502166 52 112426 38G (26T) 144953 51 502166 52 112426 38**NOTE:D=DomesticND=Non-DomesticHD=HeavyDutyWeightStd.=StandardWeight

BASES *(D-HD)UPCode *(ND)UPCode *(ND-Std)UPCodeItem/Description 670610 670610 Wt 670610 Wt

#4,11¼”Wide 145653 ---- 34 381532 22#6,14¾”Wide 145660 ---- 45 381525 36#160,20½”Wide 145684 ---- 68 256861 55*D=Domestic ND=Non-Domestic HD=Heavy Duty Weight Std.=Standard Weight

SEPARATE UPCODES for VALVE BOX BOTTOMS ONLY

Bottom **(D-HD)UPCode **(ND-HD)UPCode **(ND-Std.)UPCodeBox Length 670610 Wt 670610 Wt 670610 Wt

AA (12B) 145134 19 --- --- 250524 14A (18B) 145141 29 505594 29 250517 25B (24B) 145158 33 502388 33 136958 29C (30B) 145165 37 502395 37 136613 33CC (36B) 145172 39 502401 39 136620 35D (30B) 145165 37 502395 37 136613 33DD (36B) 145172 39 502401 39 136620 35E (24B) 145158 33 502388 33 136958 29F (24B) 145158 33 502388 33 136958 29G (36B) 145172 39 502401 39 136620 35 (48B) --- --- --- --- 452713 65 (60B) --- --- --- --- 452720 91

**NOTE: D=Domestic ND=Non-Domestic HD=Heavy Duty Weight Std=Standard Weight

44

Page 45: :DWHUZRUNV &DWDORJ - McWane

5¼" DROP LID W/SPECIAL MARKINGS***(D-HD)UPCode *(ND-Std)UPCode Special670610 Wt. 670610 Wt. Mark

145332 12 136873 9 GAS145349 12 136903 9 SEWER145356 12 136897 9 PLAIN458975 12 --- --- REUSE**Lids marked with “WATER” will be shipped unless otherwise specified.

5¼" MWW DROP LID*(D-HD)UPCode *(ND-HD)UPCode670610 670610 Wt.

145370 136880 12 *D=Domestic ND=Non-Domestic HD=Heavy Duty Weight

5¼" OMA DROP LID***(D-HD)UPCode *(ND-HD)UPCode Special670610 670610 Markings Wt.

145301 136927 **WATEROMA12*D=Domestic ND=Non-Domestic HD=Heavy Duty wt.**OMAmarkingisinsidelid.

STANDARD & SPECIAL DROP & LOCK LIDS

11/8"Lid

Drop Lid Lock Lid

WRENCHFits Standard Waterworks

Pentagon Head 27/32" Brass Screws

UPCode Ship670610 Code Description Wt

144908 S Wrench 0.5

LIDS (WATER) *(D-HDUP)Code *(ND-Std)UPCode *(ND-HD)UPCodeItem/Description 670610 Wt 670610 Wt 670610 Wt

5¼DropLid 145325 12 136910 9 --- ---5¼LockLid 145462 11 136866 11 --- ---1¿Lid** 145509 11 112532 9 --- ---(Usewith1¿“RiserOnly)

*NOTE:D=DomesticND=Non-DomesticHD=HeavyDutyWeight Std=StandardWeight

45

RECLAIMED WATER LID *(D-HD)UPCode 670610

458892

NOTE:SquareValveBoxTopsforthisLidwillbeavailablein2012.CallTylerUnionforinformation.*D=Domestic HD=Heavy Duty Weight

Page 46: :DWHUZRUNV &DWDORJ - McWane

FIXED & ADJUSTABLE RISERSPLUS SPECIALTY VALVE BOX TOPS

RISERS *(D-HD)UPCode. *(ND-HD)UPCode HeightItem/Description 670610 670610 Increase Wt

5¼x1¿Slip-In* 145554 112549 1¿" 85¼x2¼Slip-In 145547 112556 2¼" 14*Usewith1¿"LidOnly.*D=DomesticND=Non-DomesticHD=HeavyDuty Specialty Valve Box Tops - Call for Submittal / Product Drawing *D-UPCode Description Weight 376774 7126-26T Slip Type Special with 49 Top Flange See 29U Submittal for dimensions Lid Type: Uses Standard 5-1/4" Drop **ND-UPCode Description Weight 502883 910-18T Slip Type Special with 37 Top Flange Body: 7.0" Inside Diameter 7.5" Outside Diameter Top Flange: 12" Outside Diameter Flange 3/8" Thick Lid: Call for Information **ND-UPCode Description Weight 502890 940-18T Slip Type Special with 35 Bottom Flange Body: 6.125" Inside Diameter 6.50" Outside Diameter Bottom Flange: 9.25" Outside Diameter Flange 7/16" Thick Lid: Call for Information Note: *D = Domestic **ND = Non-Domestic

#69 SCREW TYPE ADJUSTABLE RISERFOR 6850/60 SERIES

(Uses Standard Drop Lid)*(D-HD)UPCode *(ND-HD)UPCode Height670610 670610 Increase Weight

148197 112396 2½"-9" 29

*D=DomesticND=Non-DomesticHD=HeavyDuty

#69-A SLIP TYPE ADJUSTABLE RISERFOR 6855 SERIES

(Uses Standard Drop Lid)*(D-HD)UPCode *(ND-HD)UPCode Height670610 670610 Increase Wt

148241 112204 2½"-12" 29

*D=DomesticND=Non-DomesticHD=HeavyDuty

5¼" x 2¼" Riser(Uses Standard 5¼"

Drop Lid)

5¼" x 1¿" Riser(Requires 1¿" Riser Lid)

46

Page 47: :DWHUZRUNV &DWDORJ - McWane

47

UPCode Ship670610 Code Description Weight

148449 S 6150-18Ring&LidB/L* 39148456 S 6150-18Ring&LidB/S* 39148647 S 6150-18RingOnly 27148494 S 6150-18/20LidWithLockB/L* 13148593 S 6150-L-18/20LidLessLock 14148500 S 6150-18/20LidWithLockB/S* 13148463 S 6150-20Ring&LidB/L* 41148470 S 6150-20Ring&LidB/S* 41148630 S 6150-R-20RingOnly 29*B/L=LargeHead Bolts(1-1/32");*B/S=SmallHead Bolts(27/32"Standard) NOTE: The B/L & B/S pentagon head screws use the same worm or locking gear.

6150TR (TOUCH-READER) METER COVERS CAST IRON

UPCode Ship670610 Code Description Weight

148531 S 6150-18TRRing&LidB/L” 39148524 S 6150-18TRRing&LidB/S* 39148579 S 6150-18/20TRLidWithLockB/L* 13148562 S 6150-18/20TRLidWithLockB/S* 13148586 S 6150-18/20TRLidLessLock 12148555 S 6150-20TRRing&LidB/L* 41148548 S 6150-20TRRing&LidB/S* 41*B/L=LargeHead Bolts(1-1/32");B/S=Small HeadBolts(27/32")NOTE:6150TR-Samedimensionsas6150,plusa1-27/32"accessholeinlid.NOTE: The B/L & B/S pentagon head screws use the same worm or locking gear.

6200 METER COVER, CAST IRON

UPCode Ship670610 Code Description Weight

148708 S 6200Ring&LidLessLock 28148760 S 6200-RRingOnly 18148739 S 6200-LLidLessLock 13148722 S 6200-LLidWithLock 11

METER COVERS, TOUCH-READER (TR)RINGS & LIDS

6150 & 6150TR METER COVERS,CAST IRON

Description A B C

18-in.6150Series 8¾ 18 2020-in.6150 9¾ 20 22

6200MeterCover

6150TRMeterCover

6150MeterBoxCover

WRENCH Fits Standard Waterworks

Small Pentagon Head 27/32" Brass Screws

UPCode Ship 670610 Code Description Weight

144908 S Wrench 0.5

256772_utility catalog.pdf 47 12/15/08 8:24:30 AM

Page 48: :DWHUZRUNV &DWDORJ - McWane

48

TERMS AND CONDITIONS OF SALE - McWane, Inc.

1.ENTIREAGREEMENT.McWane,Inc.,agreestosell thegoodscoveredherein(the“Goods”)toBuyeronthefollowingtermsandconditionsofsale(the“TermsandConditions”)whichsupersedeanyotherorinconsistenttermsofBuyer.ThiscontractconstitutestheentireagreementbetweenpartieswithrespecttotheGoods,andthisAgreementmaynotbemodified,amendedorwaivedinanywayexceptinwritingsignedbyanauthorizedrepresenta-tiveofSeller.Norepresentation,promiseortermnotsetforthhereinhasbeennormayberelieduponbyBuyer.AllreferencesbySellertoBuyer’sspecificationsandsimilarrequirementsareonlytodescribetheproductsandworkcoveredherebyandnowarrantiesorothertermsthereinshallhaveanyforceoreffect.

2.QUOTATIONS.WherethisformisusedbySellertoplaceabid,thequota-tionstatedhereinisforpromptacceptanceandissubjecttochangeand/orwithdrawalwithoutnotice.Promptacceptanceofallquotationsandadherencetodeliveryschedulesarematerialtermsofthebidandanysubsequentagree-ment.Incaseswherefreightallowanceisincludedinthequotation,Buyerisliableforanyrateincreaseand/oradditionalexpenseoverthecalculatedallowanceresultingfromcompliancewithBuyer’sshippinginstructions.

3.ACCEPTANCE.ThisordershallnotbebindinguponSelleruntilacceptedbyanauthorizedrepresentativeofSelleratitshomeoffice.Acceptanceoforders,whetheroralorwritten,isbasedontheexpressconditionthatBuyeragreestoalloftheseTermsandConditions.AcceptanceofdeliverybyBuyerwillconstituteBuyer’sassenttotheseTermsandConditionsintheirentirety.

4.DELIVERY.AllpricesareF.O.B.Seller’splant,unlessotherwisespecifiedbySeller.Allshippingdatesareapproximate,andanytimeperiodindicatedforashipmentshallnotcommenceuntilreceiptofSeller’sinformation.Acceptanceofshipmentbydesignatedshipper,allocationofGoodstoBuyeratpremisesotherthanSeller’s,deliverytoBuyer’srepresentativeordesignee,ormailingofaninvoicetoBuyer,whicheverfirstoccurs,shallconstitutetenderofdelivery.Upontenderofdelivery,titleshallpasstoBuyer,subjecttoSeller’srightofstoppageintransitandtoanyinterestofSellerreservedtosecureBuyer’spaymentorperformance,irrespectiveofanyfreightallowanceorprepaymentoffreight.GoodsheldsubjecttoBuyer’sinstructions,GoodsforwhichBuyerhasfailedtosupplyshippinginstructions,orinanycasewhereSeller,initssolediscretion,determinesanypartoftheGoodsshouldbeheldforBuyer’saccount,SellermayinvoicetheGoodsandBuyeragreestomakepaymentatthematurityoftheinvoicerendered.Goodsinvoicedandheldatanyloca-tionforwhateverreasonshallbeatBuyer’sriskandSellermaychargefor(butisnotobligatedtocarry)insurance,storageandotherexpensesincidenttosuchdelayatitsprevailingrates.PartialdeliveriesshallbeacceptedbyBuyerandpaidforatcontractpricesandterms.WhenBuyerhasdeclaredormanifestedanintentionnottoacceptdelivery,notendershallbeneces-sarybutSellermay,atitsoption,givenoticeinwritingtoBuyerthatSellerisreadyandwillingtodeliverandsuchnoticeshallconstituteavalidtenderofdelivery.InnoeventshallBuyerbeentitledtomakeanydeductionfromanypaymentduehereunderbyreasonoflossordamageintransit.UponthewrittenrequestofBuyer,Seller,atitssolediscretion,mayagreeasaservicetoBuyertoprocessBuyer’sclaimagainstthecarrierforanylossordamageintransit,providedthatsuchclaimisreceivedbySellerwithinfive(5)daysofthereceiptofGoods.Anysuchclaimsmustbeaccompaniedbyadeliveryreceipt,signedbycarrier’sagentattimeofdelivery,onwhichreceiptthelossordamagehasbeennoted.Intheabsenceofdirections,goodswillbeshippedbythemethodandviacarrierSellerbelievesdependable.Deliverybytruckwillbemadetonearestpointsreasonablyaccessiblebytruckasdeterminedbythedriver.BuyerwillfurnishandpayfornecessarylabortounloadandstoreGoods.BuyershallnotelossordamageontruckshipmentsupondeliveryticketreturnedtoSeller.AllmaterialsreceivedfromSellermustbecounteduponreceiptandcomparedtotheSeller’spackinglist.Anyshortagemustbenotedonthecarrier’sofficialfreightbillandbeconfirmedwiththesignatureofthedriverrepresentingthedeliveringcarrier.AcopyofthefreightbilllistingtheshortagemustbeforwardedtoSellerwithinthreeworkingdaystoreceive

creditforanyshortage.Ifthefreightbillissignedwithoutexception,thepackinglistwillbedeemedcorrectandnoshortageclaimwillbehonored.ContactSeller’ssalescorrespondentimmediatelyifnopackinglistispresent.

5.TERMSOFPAYMENT.TermstoBuyerswhosecredithasbeenapprovedinwritingbySellerarespecifiedonthefaceoftheapplicableinvoice.Sellershallhavetherighttomakepartialshipments..If,atanytimeorforanyreason,SellershallhavecausetoquestionBuyer’sabilitytoperform,SellermaydemandsuchassurancesofBuyer’sperformanceasSellershalldeemnecessaryinitsdiscretion,includingpaymentinadvanceforallshipments.IfBuyerfailswithin10daysofSeller’sdemandtoprovideSellerwithsuchassurance,Sellershallbeentitledtocancelanyorderthenoutstanding,receivereimbursementforitsreasonableandpropercancellationchargesandmayproceedtocollect,withoutlimitation,anysumsdueandowing,itsreasonablecancellationchargesandalldamageresultingfromBuyer’sdefault.IntheeventofbankruptcyorinsolvencyofBuyer,orintheeventofanyproceedingbroughtagainstBuyer,voluntarilyorinvolun-tarily,underbankruptcyoranyinsolvencylaws,Sellershallbeentitledtocancelanyorderthenoutstandingatanytimeandshallreceivereimbursementforitsreasonableandpropercancellationcharges.IfBuyerfailstomakepaymentfortheGoodswhendue,Buyer’saccountshallbedeemeddelinquentandBuyershallbeliabletoSellerforaservicechargeofeighteenpercent(18%)perannumorthemaximumallowedbylaw,whicheverisgreater,onanyunpaidamount.BuyershallbeliabletoSellerforallcostsandexpensesofcollection,includingcourtcostsandreasonableattorney’sfees.

6. CANCELLATION,CHANGESANDRETURNS. This order is not subject tocancellation, change or return unless agreed to inwriting by an authorizedrepresentativeofSeller.AtSeller’soption,BuyermaybechargedforanycostsincurredbySellerpriortoorasaresultofsuchcancellation,changeorreturn.Inthisevent,thesellershallbeentitledtoreviseitspricesanddeliverydatestoreflect such change. WhenSeller’sagreement isobtained, Sellerwill acceptreturnedmaterialforcreditif,initssolediscretion,itfindssuchmaterialtobestandardstockandingoodcondition.Suchcreditshallbetheinvoicepriceless25%onacceptablegoods,andlessallshippingandhandlingcharges. Inallothercases,thecreditinSeller’ssolediscretionshallbethescrapvalueoftheGoods,lessshippingandhandlingcharges.

7.DELAYINORPREVENTIONOFPERFORMANCE.Sellershallnotbeliableforanyexpense,lossordamageresultingfromdelayindeliveryorpreventionofperformancecausedbyfires,floods,actsofGod,strikes,labordisputes,laborshortages,lackoforinabilitytoobtainmaterials,fuels,suppliesorequipment,riots,accidents,transportationdelays,actsorfailurestoactofanygovernmentorofBuyer,oranyothercausewhatsoever,providedthatsuchcauseisbeyondthereasonablecontrolofSeller;andSellershallhavesuchadditionaltimeforperformanceasmaybereasonablynecessaryunderthecircumstancesandmayadjust theprice toreflect increasesoccasionedbysuchdelay. AcceptancebyBuyerofanyGoodsshallconstituteawaiverbyBuyerofanyclaimfordamagesonaccountofanydelayindeliveryofsuchGoods.Ifdeliveryisdelayedorinter-ruptedforanysuchcause,SellermaystoretheGoodsatBuyer’sexpenseandrisk,andSellermaychargeBuyerthereforareasonablestoragerate.IfSellerisdelayedinproceedingwithproductionorotherwisebecauseitisawaitingBuyer’sapprovaloracceptanceofdesigns,drawings,prints,engineeringor technicaldata,orisawaitingBuyer’sapprovaloracceptanceoftheGoods,SellershallbeentitledtoanadjustmentinpricecommensuratewithanyincreaseinSeller’scostofproductionandanyotherlossesandexpensesincurredbySellerattributabletosuchdelays.

8.DEFERREDDELIVERY.AnydeferreddeliveryrequestbyBuyershallbesubjecttoSeller’swrittenapproval.Ifsuchapprovalisgiven,SellershallhavetherighttochargeBuyer for thecompletedportionof theorderand towarehouseallcompletedGoodsatBuyer’sexpenseandriskofloss.Selleralsoreservestheright,at itsoption,astoanyuncompletedportionof theordertocancelsaiduncompletedportioninaccordancewithParagraph6above,ortoreviseitspricesanddeliveryschedulesontheportionnotcompletedtoreflectitsincreasedcostsandexpensesattributabletothedelay.

256772_utility catalog.pdf 48 12/15/08 8:24:30 AM

Page 49: :DWHUZRUNV &DWDORJ - McWane

49

10.PATENTS.IfanyclaimismadeagainstBuyerbasedonaclaimthatanyoftheGoodsconstituteaninfringementofanyU.S.LetterPatent,BuyershallnotifySellerimmediately.Sellershallhavetheright,withBuyer’sassistance,if required, but at Seller’s expense, to conduct settlement negotiations ofanylitigation.IfanyoftheGoodsareheldtoinfringeanyU.S.LetterPat-ent,andtheiruseisenjoinedor,ifasaresultofasettlement,Sellerdeemstheir continueduseunadvisableandprovided thatBuyerhasgivenSellerthe immediatenoticeprovidedforaboveandhasusedtheGoodsonly inaccordancewiththeprovisionsof thisorderandshallnothavealteredorchangedtheminanymaterialway,Sellershall,atitsoptionandexpense,procureforBuyertherighttocontinueusingtheGoods,modifytheGoodssothattheybecomenon-infringing,replacetheGoodswithnon-infringingGoodsofsubstantiallyequalquality,orreplacetheGoodsandrefundthepurchaseprice,lessreasonabledepreciation.TheforegoingstatesSeller’sentireliabilityforpatentinfringement.

11. CONTROLLINGLAW. ThisAgreementandall rightsandobligationshereundershallbegovernedbythelawsoftheStateofAlabama.orTexasAnyclaimbyBuyerarisinghereundershallbetriedinthecourtsofAlabamaorTexastowhichjurisdictionBuyerherebysubmits.

12.ARBITRATION;DISPUTERESOLUTION;PRESERVATIONOFFORECLOSUREREMEDIES.AttheoptionorelectionofSeller,anydispute,claimorcontroversy(“Dispute”)betweenSellerorBuyerrelatingtothetransactionscontemplatedbythisagreement,includingwithoutlimitationanyclaimbasedonorarisingfromanallegedtort,shallberesolvedbybindingarbitrationinaccordancewithTitle9of theU.S.CodeandtheCommercialArbitrationRulesof theAmericanArbitrationAssociation(the“AAA”).Defensesbasedonstatutesoflimitationandsimilardoctrinesshallbeapplicableinanysuchproceeding,andthecommencementofanarbitrationproceedingunderthisAgreementshallbedeemedthecommencementofanactionforsuchpurposes.ThearbitratorshallbeselectedinaccordancewiththeCommercialArbitrationRulesof theAAA. TheAAAshalldesignateapanelof ten (10)potentialarbitratorsknowledgeableinthesubjectmatteroftheDispute.EachSellerandBuyer shalldesignate,within thirty (30)daysof the receiptof the listof potential arbitrators, one of the potential arbitrators to serve, and thetwoarbitrators sodesignatedshall selecta thirdarbitrator from theeightremainingcandidates.

13.WAIVER.NodelayorfailurebySellertoexerciseanyrightorremedyundertheseTermsandConditionsshallbeconstruedtobeawaiverthereof.WaiverbySellerofanybreachshallbelimitedtothespecificbreachsowaivedandshallnotbeconstruedasawaiverofanysubsequentbreachofthisor-deroranyrightshereunderwithoutthepriorwrittenconsentofSeller.ThisAgreement,andtheTermsandConditionscontainedherein,areenforceable,however,againstthesuccessorsandassignsofBuyer.

14.ASSIGNMENT.Buyermaynotassignthisorderoranyrightshereunderwithoutthepriorwrittenconsentofseller.ThisagreementandtheTermsandConditionscontainedherein,areenforceable,however,againstthesuccessorsandassignsofBuyer.

15.TAXES.Seller’spricesdonotincludesales,use,exciseorothersimilartaxes.Consequently,inadditiontothepricespecifiedherein,theamountofanypresentorfuturesuchtaxshallbepaidbyBuyer,orinlieuthereof,BuyershallprovideSellerwithalltax-exemptioncertificatesrequiredbythetaxingauthorities,atthetimeofsale.

16.CUMULATIVENATUREOFREMEDIES.AllremediesofSellersetforthhereinshallbecumulativeandshallbeinadditiontoanyotherremediesavailabletoSeller,whetheratlaw,equityorotherwise.

TERMS AND CONDITIONS OF SALE - McWane, Inc.

9.WARRANTYANDLIMITATIONOFLIABILITIESANDBUYER’SREMEDIES.SellerwarrantsthattheGoodsdeliveredhereunderwillbeofthekinddescribedinthewithinagreementand shall be free fromdefects inmaterial andworkmanshipunderconditionsofnormaluse.SellerreservestherighttomakeanymodificationsrequiredbyproductionconditionstotheinformationsetforthinSeller’scataloguesandadvertisingliterature.Sellershallnotbeliableorresponsible,however,for(A)anydefectsattributedtonormalwearandtear,erosionorcorrosionorimproperstorage,useormaintenance,or(B)defects inanyportionorpartof theGoodsmanufacturedbyothers.If(B)aboveisapplicable,Sellerwill,asanaccommodationtoBuyer,assigntoBuyeranywarrantiesgiventoitbyanysuchothermanufacturers.AnyclaimbyBuyerwithreferencetotheGoodsforanycauseshallbedeemedwaivedbyBuyerunlesssubmittedtoSellerinwritingwithinten(10)daysfromthedateBuyerdiscovered,orshouldhavediscovered,anyclaimedbreach.BuyershallgiveSelleranopportunitytoinvestigate.

ProvidedthatSellerisfurnishedpromptnoticebyBuyerofanydefectandanop-portunitytoinspecttheallegeddefectasprovidedherein,Sellershall,atitsoptionandinitssolediscretioneither:(I)repairthedefectiveornon-conformingGoods,(ii)replacethenonconformingGoods,orpartthereof,whicharesenttoSellerbyBuyerwithinsixtydaysafterreceiptoftheGoodsatBuyer’splantorstoragefacilities,or(iii)ifSellerisunableorchoosesnottorepairorreplace,returnthepurchasepricethathasbeenpaidandcancelanyobligationtopayunpaidportionsofthepurchasepriceofnonconformingGoods.Innoeventshallanyobligationtopayorrefundexceedthepurchasepriceactuallypaid.Repairand/orreplacementasprovidedaboveshallbeatSeller’splantandshippedFOBPlantunlessotherwiseagreedtobySeller.TransportationchargesforthereturnoftheGoodsorpartthereof to Seller shall be prepaid by Buyer unless otherwise agreed to by theSellerinwriting.Sellershall,innoevent,beresponsibleforanylabor,removalor installation charges thatmay result from theabove-described repair and/orreplacementofanyGoods.Theforegoingwarrantydoesnotcoverfailureofanypartorpartsmanufacturedbyothers,thefailureofanypartorpartsfromexternalforces,includingbutnotlimitedtoearthquake,installation,vandalism,vehicularorother impact,applicationofexcessivetorquetotheoperatingmechanismorfrostheave.TheexclusiveremedyofBuyerandthesoleliabilityofSeller,foranyloss,damage,injuryorexpenseofanykindarisingfromthemanufacture,delivery,sale,installation,useorshipmentoftheGoodsandwhetherbasedoncontract,warranty,tortoranyotherbasisofrecoverywhatsoever,shallbe,attheelectionofSeller,theremediesdescribedabove.TheforegoingisintendedasacompleteallocationoftherisksbetweenthepartiesandBuyerunderstandsthatitwillnotbeabletorecoverconsequentialdamageseventhoughitmaysuffersuchdam-agesinsubstantialamounts.BecausethisAgreementandthepricepaidreflectsuchallocation,thislimitationwillnothavefailedofitsessentialpurposeevenifitoperatestobarrecoveryforsuchconsequentialdamages.

THEFOREGOINGWARRANTYISEXCLUSIVEANDINLIEUOFALLOTHERWARRAN-TIESWHETHEREXPRESSORIMPLIEDBYLAW.THEREISNOIMPLIEDWARRANTYOFMERCHANTABILITYORFITNESSFORAPARTICULARPURPOSE.INNOEVENT,WHETHERASARESULTOFBREACHOFCONTRACT,WARRANTY,TORT(INCLUDINGNEGLIGENCE)ORSTRICTLIABILITY,SHALLSELLERBELIABLEFORANYPUNITIVE,SPECIAL, INCIDENTALORCONSEQUENTIALDAMAGES INCLUDING,BUTNOTLIMITEDTO,LOSSOFPROFIT,LOSSOFUSEOFTHEGOODSOROTHERPROP-ERTYEQUIPMENT,DAMAGETOOTHERPROPERTY,COSTOFCAPITAL,COSTOFSUBSTITUTEGOODS,DOWNTIME,OR THECLAIMSOF BUYER’SCUSTOMERSFORANYOFTHEAFORESAIDDAMAGES.SELLERSHALLNOTBELIABLEFORANDBUYERAGREESTO INDEMNIFYSELLERFORALLPERSONAL INJURY,PROPERTYDAMAGEOROTHER LIABILITY RESULTING INWHOLEOR IN PART FROMTHENEGLIGENCEOFBUYER.

InanycontractbyBuyerforresaleofgoods,buyershalleffectivelydisclaim,asagainstSeller,anyimpliedwarrantyofmerchantabilityandallliabilityforpropertydamageorpersonalinjuryresultingfromthehandling,possessionoruseoftheGoods,andshallexclude,asagainstSeller,anyliabilityforspecialorconsequentialdamages.

256772_utility catalog.pdf 49 12/15/08 8:24:31 AM

Page 50: :DWHUZRUNV &DWDORJ - McWane

50

1. PlaceadapterflangeandMJgasketovertheplainendofthepipewiththesmallsideoftheMJgasketfacingtheflangesideoftheadapterflange.

2. PlacethepipeendagainstflangetobejoinedandsliptheMJgasketintopositionagainsttheflange.Makesurethegasketisevenlyseatedagainsttheflange.

3. Slideadapterflangeintopositionagainstthesmall(tapered)sideoftheMJgasketandaligntheboltholes.Inserttheboltsandfingertightenthenutstomaintainpositionandalignment.

4. Snugupallnutsevenly.Alternating@180°,tightenthenutstoatorqueof:3"-60footpounds;4"thru12"-90footpounds.

5. Snugupallsetscrewsevenlyaroundthepipe.TightentheTorqueHeadSetScrewsevenly,alternatingat180degrees.

NOTE:THETORQUEHEADTOPWILLBREAKOFFATTHERECOMMENDEDSETTINGOF80-90FT.LBS. MAXIMUMDEFLECTIONOFJOINT(2°)

WallThicknessNote:RecommendedforductileironpipeClass53thruClass56.

ADAPTER FLANGE

FM APPROVED

PipeWallThickness:Sizes3"-12"arerecommendedforduc-tileironpipeclass50thru56.Sizes14"thru24"arerecom-mendedforductileironpipeclass53thru56.

*SET-SCREW RETAINER GLAND

1. Washbellandplainendwithsoapywater,thenslipglandandgasketoverplainendwiththesmallsideofthegasketandringsideoftheglandfacingthebell.

2. Slipplainendintobell.Brushsoapywaterongasket.Thislubricatesthegasketandallowsittoslipeasilyintoplace.Pushgasketintobellmakingsureitisevenlyinthebellgasketlanding.

3. Slidetheglandintopositionagainstthebackofthegasket.Alignboltholes,insertT-boltsandtightennutstofingertight.

4. SnugupallT-boltnutsevenly.Alternatingat180°,tightentheT-boltnutstoatorqueof:

3"-60footpounds4"thru24"-90footpounds.

5. Snugupallsetscrewsevenly.Usingatorquewrench,tightenthesetscrewsalternatingat180°totherecommendedtorquevalueof75footpounds.Ifrequireddoublechecksetscrewsimmediately.

Maximumrecommendeddeflectionofjoints:

3"thru12"-2°;14"thru30"-1°*Note: Not recommended for use on plain end fittings

ASSEMBLY INSTRUCTIONS

256772_utility catalog.pdf 50 12/15/08 8:24:31 AM

Page 51: :DWHUZRUNV &DWDORJ - McWane

51

MAKING OFFSETS ON THE JOB

UsingTwoBends—OffsetinInches

Nominal C153-A21.53Diameter MechanicalJoint Inches 90° 45° 22½° 11¼°

3 14.00 6.36 3.06 1.46 4 15.00 7.07 3.31 1.58 6 18.00 8.48 3.89 1.68 8 20.00 9.19 4.09 1.77 10 24.00 10.61 4.48 1.88 12 26.00 12.02 4.87 1.97 14 31.50 13.08 5.88 2.47 16 33.50 13.79 5.92 2.48 18 38.00 14.14 8.92 2.54 24 41.50 16.40 9.76 4.97 30 N/A N/A N/A N/A

D R L† Angle Equals Equals Equals

45° Tx1.414 Tx1.000 D-2A 22½° Tx2.613 Tx2.414 D-2A 11¼° Tx5.126 Tx5.027 D-2A †CutthePipesomewhatshortertoallowforclearanceinthejoints.

Example:A14-inchMechanicalJointlineistobeoffset12feetonanangleof45-degreesusingtwoC110full-bodyMechanicalJointbends.Whatisthelayinglength(L)ofpiperequiredtomaketheconnectionbetweenthetwobends?

Solution:D=12'0"x1.414=16.968'R=12'x1.000=12.000'A=7.5"or.625'L=16.968'-1.250=15.718'orapproximately15'8Á".

MechanicalJoint

Nominal C110-A21.10Diameter MechanicalJoint Inches 90° 45° 22½° 11¼°

3 19.60 10.25 5.56 2.63 4 21.50 11.69 6.31 3.02 6 24.50 13.06 7.08 3.41 8 26.60 13.76 7.50 3.61 10 30.50 15.19 8.25 4.00 12 32.50 16.62 9.00 4.39 14 36.50 16.62 8.99 4.39 16 38.50 17.32 9.38 4.58 18 41.50 18.03 9.76 4.78 20 44.50 19.45 10.52 5.17 24 52.50 21.57 11.67 5.75 30 58.50 27.23 14.73 7.32

Nominal C110-A21.10 LongDiameter StandardFlange Radius Inches 90° 45° 22½° 11¼° 90°

3 11.00 4.24 2.30 1.17 15.50 4 13.00 5.66 3.06 1.56 18.00 6 16.00 7.07 3.83 1.95 23.00 8 18.00 7.78 4.21 2.15 28.00 10 22.00 9.19 4.98 2.54 33.00 12 24.00 10.61 5.74 2.93 38.00 14 28.00 10.61 6.74 2.93 43.00 16 30.00 11.31 6.12 3.12 48.00 18 33.00 12.02 6.51 3.32 53.00 20 36.00 13.44 7.27 3.71 58.00 24 44.00 15.56 8.42 4.29 68.00 30 50.00 21.22 11.48 5.85 N/A

DETERMININGLENGTHOFPIPEINOFFSETS

FlangedJoint*Noallowanceismadeinoffsetfiguresforgasketthick-ness.

MechanicalJoint

256772_utility catalog.pdf 51 12/15/08 8:24:32 AM

Page 52: :DWHUZRUNV &DWDORJ - McWane

52

MIN.-MAX. DR41 40,80,120 32.5 C905IPS PIPE 25.18 DIA.14-24 SIZE

1-1/2" 1.90±.06 1.90 STD. 1.90 2" 2.50 2.30±.09 2.35±.09 2.38 2.50 2.38 STD. 2.38 2-1/2" 2.88 STD. 2.88 A 3.80 3.30±.09 3.35±.09 3.50 100 3.74 4.00 3.50 STD. 3.50 3" B,C,D 50-350 3.96 150 3.84 4.10 200 3.84 4.29 A 50-350 4.80 4.30±.09 4.38+.09 4.50 100 4.64 4.79-5.14 4.80 4.50 O.D. 4.00 4" B,C,D 5.00 -.05 150 4.81 4.97-5.27 STD. 4.50 200 4.81 5.22-5.57 5" 5.30±.09 5.30+.09 5.50 5.56 STD. 5.56 -.05 A 50-350 6.90 6.30±.09 6.30+.09 6.50 100 6.91 7.05-7.40 6.90 6.63 O.D. 6.00 6" B,C,D 7.10 -.05 150 6.91 7.07-7.37 STD. 6.63 E,F 7.22 200 6.91 7.26-7.56 A,B 50-300 9.05 8.38±.13 8.38+.13 8.62 100 9.11 9.22-9.57 9.05 8.63 O.D. 8.00 8" C,D 350 9.30 -.09 150 9.11 9.27-9.57 STD. 8.63 E,F 9.42 200 9.11 9.39-9.74 A,B 50-200 11.10 10.50±.13 10.56±.09 10.75 100 11.24 11.42-11.77 11.10 10.75. O.D. 10.00 10" C,D 250-350 11.40 150 11.66 11.82-12.12 STD. 10.75 E,F 11.60 200 11.66 11.77-12.12 A,B 50-200 13.20 12.50±19 12.50±.09 12.75 100 13.44 13.69-14.04 13.20 12.75 O.D. 12.00 12" C,D 250-350 13.50 150 13.92 14.08-14.38 STD. 12.75 E,F 13.76 200 13.92 14.03-14.38 A,B 50-100 15.30 100 15.07 15.40-15.80 15.30 O.D. 14.00 14" C,D 150-300 15.65 150 16.22 16.38-16.73 E,F 16.98 200 16.22 16.48-16.88 15" 15.88±.19 15.83±.09 15.88 A,B 50-100 17.40 100 17.14 17.54-17.94 17.40 O.D. 16.00 16" C,D 150-300 17.80 150 18.46 18.62-18.97 E,F 18.16 200 18.46 18.79-19.19 18" A,B 50-100 19.50 100 19.90 20.44 19.50 STD. 18.00 C,D 150-250 19.92 150 20.94 21.20 20" A,B 50-100 21.60 100 22.12 22.50 21.60 STD. 20.00 C,D 50-250 22.06 150 23.28 23.54 24" A,B 50-100 25.80 100 26.48 27.17 25.80 STD. 24.00 C,D 150-250 26.32 150 27.96 28.22

PIPE O.D. CHART GRAY/DI IRON CAST IRON/DWV ASBESTOS - CEMENT PVC PVC PVC STEEL CLASSES O.D. SV NH XH CLASS MACHINED ROUGH C-900 C-905 STEEL O.D TYPE O.D. PIT SPUN END O.D. BARREL O.D. DI O.D. DI O.D. SCH. PIPE

PIPE O.D.'S AND FLANGE DATA

125LB.FlangesAndBolts

Size Diamof Bolt Numberof DiamOf Length Flange Circle Bolts Bolts OfBolts

2 6 4¾ 4 Á 2 2½ 7 5½ 4 Á 2¼ 3 7½ 6 4 Á 2½ 3½ 8½ 7 8 Á 2½ 4 9 7½ 8 Á 2¾ 5 10 8½ 8 ¾ 3 6 11 9½ 8 ¾ 3 8 13½ 11¾ 8 ¾ 3¼ 10 16 14¼ 12 Â 3½ 12 19 17 12 Â 3¾ 14 21 18¾ 12 1 4¼ 16 23½ 21¼ 16 1 4¼ 18 25 22¾ 16 1¿ 4¾ 20 27½ 25 20 1¿ 5 24 32 29½ 20 1¼ 5½

250L.B.FlangesAndBolts

Pipe Diamof Diamof Numberof Diamof Length Sizes Flanges WtCircle Bolts Bolts ofBolts

2 6½ 5 8 Á 2½ 2½ 7½ 5Â 8 ¾ 3 3 8¼ 6Á 8 ¾ 3¼ 3½ 9 7¼ 8 ¾ 3¼ 4 10 7Â 8 ¾ 3½ 5 11 9¼ 8 ¾ 3¾ 6 12½ 10Á 12 ¾ 3¾ 8 15 13 12 Â 4¼ 10 17½ 15¼ 16 1 5 12 20½ 17¾ 16 1¿ 5½ 14 23 20¼ 20 1¿ 5¾ 16 25½ 22½ 20 1¼ 6 18 28 24¾ 24 1¼ 6¼ 20 30½ 27 24 1¼ 6¾ 24 36 32 24 1½ 7½

BecausemanyitemslistedarenotmadebyTylerPipe,wecannotbecertainthatalldataiscurrentoraccurate.Pleasecheckwiththeproduct

manufacturerfortheirmostrecentinformation.

256772_utility catalog.pdf 52 12/15/08 8:24:32 AM

Page 53: :DWHUZRUNV &DWDORJ - McWane

53

question: FromwhatcompoundisthestandardMJgasketmadeof andwhatisthehighestwatertemperatureitwillwithstand?AretheTYTON®Push-on gasketsmadefromthesamecompound?

Answer:ThestandardMJand Push-on gasketismadeofvulcanizedstyrenebutadienerubber(SBR)in accordancewithANSI/AWWAC111/A21.11.TherecommendedtemperaturerangeforSBRgasketsisfrom20°Fto180°F.SBRgasketsaresuitableforwaterandwastewater,mostmoderatechemicals,wetordryorganicacids,alcohols,ketones, *chloramines,andaldehydes.SBRGASKETSARENOTRECOMMENDED FOR HYDROCARBON SERVICE*Note: Rated for Chloramine concentrations of less than 5 parts per million. NOTE: Review the 31U Submittal on pages 69 and 70 of this catalog for additional gasket information question:DoesTylerUnion Waterworks offeranyothergasketsthatwillwithstandtemperaturesgreater than180 F or for specialserviceapplications? Answer:Yes!TylerUnion offersfourotherspecialservicesgasketsforMJconnectionsonly.Identification,temperaturerangeandapplicationsarelistedbelow: EPDM(EthylenePropylene)- Minus 10°Fto250°FIdealforwaterandwastewater,ozoneandstrong

oxidizingchemicals.Maybeusedonsteamwithingiventemperaturerangeandonhotairwithouthydrocarbons.NOTRECOMMENDEDFORHYDROCARBONSERVICE.

NEOPRENE(CR)- Minus 10°Fto200°FRecommendedformoderatechemicalsandacids,oilfats,

manysolventsandairwithhydrocarbons.Willnotsupportcombustion.

Nitrile(NBR)(Buna-N)(Hycar)- Minus 40°Fto250°FIdeallysuitedforgasoline,petroleumproducts,hydrocarbons,waterandmineralandvegetableoils.

FKM (Fluoroelastomer) Minus 10F to 425F Ideal for hydrocarbons, acids, vegetable oils, and petrolium question:AccordingtoAWWA,howmuchtorqueshouldbeappliedtoMechanicalJointT-bolts? Answer:Therecommendedtorqueranges,asstatedinANSI/AWWAC600are: JointSize RangeofTorque in. (mm) ft/lb N/m 3 (76) 45-60 (61-81) 4-24 (102-610) 75-90 (102-122)30-36 (762-914) 100-120 (136-163)42-48 (1067-1219) 120-150 (163-203) question:WhattypeofMechanicalJointT-boltdoesTylerUnion Waterworks furnish? Answer:TylerUnion suppliesHigh-strength,Low-AlloySteelT-bolts,incompliancewithANSI/AWWAC111/A21.11. Contents of standard MJ Accessory packs comply with ANSI/AWWA C111/A21.11.Anti-RotationT-bolts,Blue Fluoropolymer coatedT-boltsandStainlessSteel(AISI316 and AISI 304)T-bolts are also available for specialapplicationsonrequest.

FREqUENTLY ASKED qUESTIONS

256772_utility catalog.pdf 53 12/15/08 8:24:32 AM

Page 54: :DWHUZRUNV &DWDORJ - McWane

54

question:WhatmaterialaretheStandardT-bolts,Anti-RotationandFluorokote #1 T-boltsmade of?

Answer:TheStandardT-boltsandAnti-RotationT-boltsandNutsaremanufacturedfromASTM A242CorrosionResistent,High-Strength,Low-AlloyWeathering SteelinaccordancewithANSI/AWWAC111(CurrentRevision).Blue Fluorokote #1, T-boltsandNutsaremanufacturedfromthesamehighqualitymaterialasthestandardT-bolts/Nutsbutcome withablue fluoropolymer resin that is baked on and wasdevelopedfor use inhighlycorrosivesoil conditions.Fluorokote #1 blue low alloy T-boltsandNuts plus Fluorokote #1 Green SS304 and Red SS316 complywithANSI/AWWAC111/A21.11(CurrentRevision).

question:Howisthetorquerangeforflangedfittingsand gasketsdetermined?

Answer: Therequired torqueforflangedfittingsand gaskets isnotaddressedintheANSI/AWWAC600Standard.Generally,thistorquerangeisdeterminedbytheflangegasketmanufacturerdue to thevarioustypes of gaskets, bolt patterns and fitting flange diameters available.

question:Whatpurposedoescementmortarliningserve?

Answer:Cementmortarliningservestopreventtuberculationthus maintainingflowcharacteristics.

question:Whatfunctiondoes the sealcoating of fittings serve?

Answer:The seal coating applied to a freshly applied cement lining provides for a controlled curing byproviding a barrier that allows for a controlled loss ofmoisture from the cement resulting in a mortarlining with improved strength. TylerUnion appliesasealcoat that is NSF-61 approved for use in potablewatersystemsand it will cover the entire fitting unless specified otherwise during order placement. Theexterior is coatedforaestheticsandto aid in retarding corrosionprior to installation.

question:ArethefittingsfurnishedbyTylerUnion WaterworksUL/FMapproved?

Answer:TylerUnion ductile iron ANSI/AWWA C110/A21.10MJ and Flange Watermainfittings3" thru 12" are UL listed for Fire Main Equipment andANSI/AWWAC153/A21.53MJ, Flange, & Union-Titefittings for *3" thru 16" are UL listed for Fire MainEquipment.(UL Listing#EX2111)(Union-Tite 4" to 16")

question:DoesTylerUnion Waterworks offerfittingswithanycoatingsotherthananasphalticsealcoat?

Answer: Yes.ForFlangedFullBody (C110)andCompact(C153) fittings,TylerUnion offersanexteriorprime coatofTnemecN140-1211Pota-PoxPlusthatisNSF-61approvedforpotablewatersystemsand is accompanied by acementmortar/sealcoatedlining.TylerUnion alsooffersdoublecementlining uponrequest. Bare castings are available upon request.Additionally Tyler Union offers a full line of ProtectiveFusion bonded epoxy coated and lined fittings for drinking water service applications.Other specialty coatings and linings may be available upon request; contact your Tyler Union Inside Sales representativefor more information. Tyler Union's Fusion bonded epoxy fittings are redoxidein colorand the coatingand lining come standard with 6 to 8 mil average thickness plus meet the applicable requirements of ANSI/AWWA C116/A21.16. For additional FBE information, see the 20U submittal on pages 58 and 59.

question:DoesTylerUnion Waterworks offerfitting interior coatingsforwastewateror sewer systems?

Answer:Yes, under some conditions. Contact your Tyler Union representative for information.

FREqUENTLY ASKED qUESTIONS

256772_utility catalog.pdf 54 12/15/08 8:24:32 AM

Page 55: :DWHUZRUNV &DWDORJ - McWane

Excavation dimensions - MJ 4" through 12" Tapping Sleeves for Ductile Pipe 55

*ASTM A242 High Strength Low Alloy Steel (Coated or Uncoated)*ANSI 304 or 316 AISI Stainless Steel (Coated Green or Red) *Flouropolymer is Fluorokote #1 (Blue for Low Alloy Steel)

BOLTS AND NUTS FOR MECHANICAL JOINTS

*Bolts and Nuts meet ANSI/AWWA C111/A21.11

T-Head Low Alloy Weathering and AISI Stainless Steel Fasteners Dimensions in Inches

A B C D† Threads F H J R Size ±0.05 +0.030 +0.25 perInch +0.15 Max. Inches -0.074 -0.06 E†† -0.03

Á x3 1.50 0.625 3.0 2.00 11 0.625 +or -.04 1.062-.04 0.625 0.312 ¾ x3.5 1.75 0.750 3.5 2.50 10 0.750 +or -.06 1.250 -.06 0.750 0.375 ¾ x 4 1.75 0.750 4.0 3.00 10 0.750 +or -.06 1.250 -.06 0.750 0.375 ¾ x 4.5 1.75 0.750 4.5 3.00 10 0.750 +or -.06 1.250 -.06 0.750 0.375 ¾ x5 1.75 0.750 5.0 3.00 10 0.750 +or -.06 1.250 -.06 0.750 0.375 1 x 6 1.75 1.000 6.0 3.00 8 1.000 +or -.08 1.625 -.08 1.000 0.500 1 x 7.5 2.25 1.000 7.5 4.50 8 1.000 +or -.08 1.625 -.08 1.000 0.625 1-1/4 x 6.5 2.50 1.250 6.5 3.50 7 1.250 +or -.08 2.000 -.08 1.250 0.750 1-1/4 x 8.5 2.50 1.250 8.5 4.00 7 1.250 +or -.08 2.000 -.08 1.250 0.750 The tolerance for cast iron bolts is +or-0.03". If threads are rolled, the body diameter may be reduced to the approximate pitch diameter of the thread.† Tolerance: +3, - 0 threads ††Numberofthreadsperinch-course-threadseries(ANSI/ASMEB1.1),Class2A,.

course-threads series (ANSI.ASME B1.1), Class 2A, external fit UNC2A and Class 2B, UNC2B (ANSI/ASME B1.2

NOTES:1. Dimension“B”isunthread-edshank.

2. Draft,whenrequiredtobe6degreemaximum,maybedeductedfromboltheaddimensions,andradius(B/2)maybechangedtosuitdraft.

3. Gates,ifrequired,mayprotrudeamaximumof1/8inchabovethetopofthebolthead.

4. Chamferisoptionalifthreadsarerolled.

256772_utility catalog.pdf 55 12/15/08 8:24:33 AM

Page 56: :DWHUZRUNV &DWDORJ - McWane

56

MJ FIELD LOK® A RESTRAINT REVOLUTION.Spendlesstime- andmoney-restrainingmechancialjointfittings

withthenewMJFIELDLOK®Gasket.

PROVENJOINT RESTRAINTTECHNOLOGY

NOLEARNINGCURVE

FORDUCTILEIRON ANDPVCPIPE

CURRENTLYAVAILABLE: DuctileIron—4"-24"

PVC—4"-12"

ULListedandFMapproved.•

Provenjointrestrainttechnology.•

Nolearningcurve-installsjustlikeastandard •mechanicaljointgasketandgland.

Nomoreneedfortime-consumingthrustblocksor•heavylug-typerestraints.

Noloosewedgesortorque-offcontrolnutstoget •lostorbroken.

Canbedisassembledjustlikeastandardmechani-•caljoint.

Suitableforpotablewaterandwastewaterapplica-•tions.

Thestate-of-the-artMJFIELDLOK• TMGlandis designedformaximumstrengthandeasyproductidentification.

MJFIELDLOK• ®GasketsareprovidedaspartofakitthatalsoincludestheMJFIELDLOKTMGland,nutsandbolts.

MJ FIELD LOK® Gasket Series DICan be used on any Pressure Class or Special Thickness •Class Ductile Iron pipe up to 350 psi. Not recommended

for use with Plain end Ductile iron fittings. Stainless steel locking segments provide proven joint • restraint technology.

MJ FIELD LOK® Gasket Series PVCan be used on any thickness class of AWWA C900 and •C909 pipe.

Pressure rated at a 2:1 safety factor, based on the pres-•sure rating of the pipe on which it is installed.

Ductile iron locking ring provides proven joint restraint •technology.

MJ FIELD LOK® Gland Highly engineered to provide the strength and •rigidity necessary for restrained joint applications.

Installs just like a standard mechanical joint gland.•

All ductile iron components are manufactured to ASTM •A536 Grade 70-50-05.

MJ FIELD LOK® Gasket Series PV

MJ FIELD LOK® Gasket Series DIMJ FIELD LOK® Gland

256772_utility catalog.pdf 57 12/15/08 8:24:33 AM

Page 57: :DWHUZRUNV &DWDORJ - McWane

57

MJ FIELD LOK® Gasket Series DI

APPROX. SIzE PIPE ORDER NO. OF PRESSURE KIT (Inches) OD NUMBER SEGMENTS RATING WEIGHT

4 4.80 DI04 3 350 7.3 6 6.90 DI06 4 350 10.9 8 9.05 DI08 6 350 13.5 10 11.10 DI10 9 350 18.5 12 13.20 DI12 13 350 19.7 14 15.30 DI14 18 350 26.9 16 17.40 DI16 24 350 31.8 18 19.50 DI18 30 250 49.8 20 21.60 DI20 36 250 59.7 24 25.80 DI24 52 250 81.3

MJ FIELD LOK® Gasket Series PV

PRESSURE PRESSURE APPROX. SIzE PIPE ORDER RATING RATING KIT (Inches) OD NUMBER DR-18 DR-14 WEIGHT (psi) (psi)

4 4.80 PV04 150 200 7.8 6 6.90 PV06 150 200 11.8 8 9.05 PV08 150 200 14.8 10 11.10 PV10 150 200 20.1 12 13.20 PV12 150 200 21.6

MJ FIELD LOK® Gland (See illustration at right)

DIMENSION SIzE WEIGHT A B C D E (Inches) (pounds) (Outside Dim) (Bolt Hole) (Inside Dia.) (OD Lip) (Gland Height)

4 3.3 8.88 7.50 4.90 5.92 1.75 6 5.0 10.87 9.50 7.00 8.02 2.00 8 7.2 13.13 11.75 9.15 10.17 2.25 10 10.2 15.38 14.00 11.20 12.22 2.25 12 11.0 17.63 16.25 13.30 14.32 2.25 14 17.2 20.13 18.75 15.44 16.40 2.51 16 25.0 22.38 21.00 17.54 18.50 2.75 18 38.0 24.75 23.25 19.64 20.60 3.14 20 46.0 27.00 25.50 21.74 22.70 3.20 24 64.0 31.50 30.00 25.94 26.90 3.57

MJ FIELD LOKTM Gland

1. MJFIELDLOK®GasketsaredesignedtosealandrestrainacentrifugallycastductileironorPVCpipespigotineitheraductileironpipeoraductileironfittingbell.

2. MJFIELDLOKGasketsare availabletofitmechanicaljointsconformingtoAWWAC110orAWWAC153in4"-24"sizes.

3. Ifductileironpipewithalowerpressureratingisused,thenthelowerpressureratingwillapplytotheMJFIELDLOKGasketalso.

4. MJFIELDLOKGasketsrequire90ft-lbofbolttorquefor4"-8"gaskets,and120ft-lbofbolttorquefor10"-12"inchgaskets.Mostcommon1/2"driveairpoweredimpactwrenchesarecapableofapplyingthesetorques.

5. MJFIELDLOKGasketsare suitableforeitherpotablewaterorwastewaterapplications.

6. MJFIELDLOKGasketsare NSFapproved,ULListedand FMApproved.

7. MJFIELDLOKGasketSeriesDIproductsarenotrecommendedforusewithcastironpipe,plasticpipe,oversizepipe,metricpipe,plain end DI fittings, or asa“transition”gasket.

8. MJFIELDLOKGasketSeriesPV productsarenotrecommendedforusewithcastironpipe,ductileironpipe,oversizepipe,metricpipe,orforuseasa“transition”gasket.

9.MJFIELDLOKGasketsarewarrantedonlywhenusedwithMJFIELDLOKTM Gland.

Application Notes:

Suggested Specifications:JointrestraintformechanicaljointpipeandfittingsshallbetheMJFIELDLOK®Gasket.Therestraintsystemshallbecompletelyintegraltothegasket,requiringonlystandardmechanicaljointassemblytechniques.Therestrainingsystemforductileironshallbepressureratedto350psiinsizesuptoandincluding16";18",20"and24"areratedfor250psi.TherestrainingsystemforPVCshallberatedata2:1safetyfactorforthepipeonwhichitisinstalled.TherestrainingsystemshallberatedinaccordancewiththeperformancerequirementsofANSI/AWWAC111/A21.11RubberGasketJointsforDuctile-IronPressurePipeandFittings. Not recommended for use on Ductile iron Plain end fittings.

256772_utility catalog.pdf 58 12/15/08 8:24:33 AM

Page 58: :DWHUZRUNV &DWDORJ - McWane

20U ● AWWA - Protective Fusion Bonded Epoxy Revised: 11/02/2011

SUBMITTAL (Current Revisions for All Standards Apply)

Tyler Union Protective Fusion Bonded Epoxy Waterworks fittings are coated on the internal and external 

surfaces in accordance with all the applicable terms and conditions of the ANSI/AWWA C116/A21.16‐09 standard. Section 4.3.2 of AWWA C116 provides that FBE mil thickness in the joint area shall not have a coating of less than 4 mil, and advises it may be necessary to establish a limit for the maximum applied thickness in the joint areas to maintain a leakproof joint. Tyler Union Waterworks standard applied coating is *6 to 8  mil.  

 

Tyler Union can provide fittings with a 10‐12 mil coating, but does not provide warranty for FBE lined fittings with greater than 8 mil thickness in the joint area.  It has been determined that fittings with epoxy coating thickness greater than 8 mil in the joint area can prevent proper joint assembly (pipe will not insert properly and gasket will not seat fully).   

 

The ANSI/AWWA C116/A21.16‐09 standard describes the use of protective fusion‐bonded epoxy coatings as being utilized for the interior and exterior surfaces of ductile‐iron and gray‐iron fittings supplied for “water systems”.  Section 1.1 of the AWWA C116 standard specifically provides that the standard does not cover instances where coatings are agreed upon by purchaser and manufacturer for sewer or other special applications. 

  Though not always recommended for use in **Sewer systems; Tyler Union Protective Fusion Bonded Epoxy 

coated fittings may be used in sewer applications  within the parameters as provided. Tyler  Union Waterworks FBE has  been tested according to UL262; this involves immersing coated parts in four aqueous solutions at 158°F and evaluatingthe coating for blistering during a 90 day exposure period. The four solutions consist of distilled water, 2% sodiumchloride in distilled water, distilled water with the pH adjusted to 4.0 using potassium hydrogen phtalate, and distilled water with the pH adjusted to 10.0 using sodium carbonate. During testing Tyler Union FBE was tested for blister  resistance upon immersion  in acid, alkali, alcohol, and hydrocarbons at room temperature over a 90 day period.Additional test data and recommended exposures for our FBE are as provided in Chart 1, Chart 2, and Chart 3. 

Chart 1: TEST  METHOD  CONDITIONS  RESULT Abrasion Resistance  ASTM D4060  CS‐17 wheels, 1000 cycles, 1 kg load  32 mg loss Adhesion  ASTM D3359 ‐ Method A  X‐cut and tape  5A Adhesion  ASTM D3359 ‐ Method B  Crosshatch and tape  5B Gloss, 60°  ASTM D523    70‐85 Humidity Resistance  ASTM D2247  1000 hours at 100°F  No blisters or rusting Impact  ASTM D2794    Pass 40 inch‐lbs. direct Pencil hardness  ASTM D3363    Pass 4H Salt Spray  ASTM B117  1000 hours  No blisters or face rust, 

no scoreline creepage Water Resistance  AWWA C550  90 days immersion at 70°C  Pass Weather Resistance  ASTM G154  UVA‐340, cycle 4 hrs UV at 60°C, 4 

hrs condensation at 50°C Chalks after 200 hours exposure 

11910 CR 492 ● Tyler, Texas 75706 ● (800) 527‐8478 

1501 W 17th St. ● Anniston, Alabama 36201 ● (800) 226‐7601 1001 El Camino Ave. ● Corona, California 92879 ● (866) 527‐8471 6204 N. Marine Dr. ● Portland, Oregon 97203 ● (866) 527‐8471  58

Page 59: :DWHUZRUNV &DWDORJ - McWane

20U ● AWWA - Protective Fusion Bonded Epoxy Revised: 11/02/2011

SUBMITTAL (Current Revisions for All Standards Apply)

Chart 2: Immersion Environments with the following chemicals (ambient temperature) 

Aliphatic Hydrocarbons  Fresh water Calcium Chloride (10% solution)  Fuel Oil Calcium Hydroxide (10% solution)  Hexane Calcium Sulfate (saturated solution)  Kerosine 

Calcium Carbonate (saturated solution)  Motor oil Distilled water  Magnesium Sulfate (saturated solution) 

Gasoline (unleaded)  Potassium Acetate (saturated solution) Diesel Fuel  Soap solutions 

Sodium Chloride (5% solution)  Sodium Nitrate (10% solution) Sodium Hydroxide (5% solution)  Trisodium Phosphate (5% solution) 

 Chart 3: Splash and Spillage Environments against the following chemicals 

Aromatic Hydrocarbons  Butanol Ethanol  Hydrochloric Acid (5% solution) 

Isopropyl Alcohol  Methanol Sulfuric Acid ( 5% solution)  Toluene 

Xylene   

*NOTE:   Utilizing AWWA prescribed application methods for applying protective fusion bonded epoxy in combination with the varying diameters, recesses, raised lettering, bosses, bolt holes,  and radiuses common with fittings; the applied thickness of the FBE coating  or  lining  

may vary by 1 to 2 mil over the painted surfaces  of  a  fitting.  **NOTE:  The suitability of this product for your application shall be determined by the end user.  Additional epoxy coatings are available up on special or der.  Please contact a Tyler Union Waterworks Inside Sales Customer representative to discuss the additional coating and lining options that are available.   

     

This document is void if modified in any manner 59  

11910 CR 492 ● Tyler, Texas 75706 ● (800) 527‐8478 1501 W 17th St. ● Anniston, Alabama 36201 ● (800) 226‐7601 

1001 El Camino Ave. ● Corona, California 92879 ● (866) 527‐8471 6204 N. Marine Dr. ● Portland, Oregon 97203 ● (866) 527‐8471

Page 60: :DWHUZRUNV &DWDORJ - McWane

21U ● AWWA Cement & Asphaltic Coating or Lining Address: 11910 CR 492 ‐ Tyler, Texas 75706            Telephone No.: (800) 527‐8478               Fax Number: (903) 882‐2347                     www.tylerunion.com

SUBMITTAL (Current revisions for all ANSI/AWWA standards apply) 

 Tyler Union Waterworks manufactures and distributes ductile iron waterworks fittings.  Tyler Union Waterworks lined and/or coated 2 

inch through 48 inch fittings are provided in accordance with and meet all the applicable terms and requirements of ANSI/AWWA C104/A21.4‐08, ANSI/AWWA C110/A21.10‐08, ANSI/AWWA C111/A21.11‐7, ANSI/AWWA C153/A21.53‐06, and ANSI/AWWA C151/A21.51.  Lined and Coated fittings distributed by Tyler Union Waterworks are NSF 61 compliant.  Current revisions apply for each noted standard.   

 The Asphaltic coating and lining utilized on the “inside” of pipe and fittings is to aide in the proper curing of the cement mortar lining as 

described in the AWWA C104 standard, Section 4.10.  Beginning in 1995 the asphaltic lining for the inside of fittings is no longer required by the AWWA but is recommended in instances where the pH of the water is less than 6.0 or greater than 10.0.   

 The purpose of the cement lining on the “inside” of ductile iron waterworks fittings is to reduce the degree of tuberculation (buildup) or 

corrosion on the fitting wall.  Tuberculation or corrosion of the fitting wall is minimized in soft or acid water as the cement lining creates a high pH at the fitting wall. The AWWA standard specified thicknesses for Cement linings and Asphaltic linings in ductile iron fittings 2 inch through 48 inch are as provided.       Fitting Sizes    AWWA Std. Cement Lining   AWWA Dbl. Cement Lining        AWWA Std. Asphaltic            Std. Tyler Union Asphaltic   2 inch to 12 inch      1/16”      1/8”      1 mil      2 mil 14 inch to 24 inch      3/32”      3/16”      1 mil      2 mil 30 inch to 48 inch      1/8”      1/4 “      1 mil      2 mil 

 The Asphaltic coating and lining utilized on the “outside” of pipe and fittings is for cosmetic purposes and intended to provide some level 

of corrosion protection prior to being installed.   Unless specified upon order placement, all cement lined fittings provided by Tyler Union Waterworks will be provided with an asphaltic lining and coating. 

   Cement Lining ‐ Field Repair  

1. Remove the damaged portion or area of the lining down to the metal surface, making sure any remaining lining edges are undercut slightly or perpendicular to the fitting wall. 

2. Clean the surface of loose debris and any tuberculation or corrosion where the lining was removed. 3. Prepare a stiff mortar from a mixture of sand, cement, and water making sure the mix contains no less than one part cement to two 

parts sand by volume.   4. Thoroughly wet the cut out area and the adjoining lining. 5. Apply mortar mix and trowel smooth with the adjoining lining 6. After any surface water has evaporated, but while the patch is still moist, cure the lining as provided. 7. The repaired cement lining can be kept moist by seal (asphaltic) coating or with the use of **wetted burlap bags placed over the 

entire waterway opening of the fitting or access point.  Once the mortar is applied to the fitting apply the seal coat by spraying or brushing on the seal coat within 5 to 15 minutes after any surface water has evaporated.  

 **Note:   1)  In instances where seal coat is not used, cure cement as provided for 24 hours after application. 

  2)  In cold weather the patched area should be protected from freezing.   3)  If Seal coat is used during field repair, allow a cure time of 48 hours after the seal coat is                 

         applied before placing fitting back in service.    Asphaltic Paint – Field Repair 

1. Paint repair to the fitting body or mechanical joint includes use of a hand steel bristle brush to remove loose corrosion.  Wipe area free of dust or debris with a cloth suitable for the task and recoat exterior areas of the fitting with the paint provided as needed using a standard paint brush sized for the task. 

2. Recoating of the cement lining is achieved by wiping the lining with a cloth to remove any loose paint or debris and then apply paint using a standard size paint brush suitable for the task applying paint to affected areas as needed. 

                                                             *Tyler Union Waterworks Contact Information* 

 Tyler:      11910 CR 492 ● Tyler, Texas 75706 ● (800) 527‐8478                              Anniston:  1501 W. 17th. St. ● Anniston, Alabama 36201 ● (800) 226‐7601 

Corona:  1001 El Camino Ave. ● Corona, California 92879 ● (866) 527‐8471          Portland:  6204 N. Marine Dr. ● Portland, Oregon 97203 ● (866) 527‐8471  

www.tylerunion.com  

                                                                                                This document is void if modified in any manner                                                    Revised 8/24/2011 60 

Page 61: :DWHUZRUNV &DWDORJ - McWane

SUBMITTAL (Current Revisions for All Standards Apply)

SIZES: ............................ 2” through 48”

STANDARDS: ................. ANSI/AWWA C110/A21.10-08 and NFPA 3”-12” UL Listed (EX2111) Note: Cast with tested and traceable ASTM A536 Ductile Iron

PRESSURE RATING: 2”- 24” rated @ 350 psi; 30”- 48” & all fittings with flanged branches rated @ 250 psi Note: With use of special flange gasket 2”- 24” flanged fittings can be rated @ 350 psi For 350 psi flange joint applications, we recommend the use of annular ring type gasket or comparable.

DEFLECTION: .................Fittings 2" - 12", *5° maximum deflection & 14" - 48", *3° maximum deflection Note: If pipe O.D. & fitting I.D. at nominal, achievable deflection is ~50% of maximum

NSF-61: ......................... Meets all requirements, UL Listed (MH16439)

ASPHALTICCOATING: ...................... ANSI/AWWA C104/A21.4 & AWWA C110/A21.10

CEMENT LINING: .......... ANSI/AWWA C104.A21.4-08, Double cement lining available

EPOXY COATING:.......... ANSI/AWWA C116/A21.16-09 Note: Fittings are available to the specification(s) required for your application(s)

BARE: ............................. Available

BOLTS: ........................... ANSI/AWWA C111/A21.11-7

INSTALLATION: ............. AWWA C600-10 using pipe conforming to ANSI/AWWA C151/A21.51-02 or ANSI/AWWA C900-C905

JOINT DIMENSIONS IN INCHES Size A B C D F Ø X J K1 K2 L M N O P S

2 2.50 2.50 3.39 3.50 2.61 28° ¾ 4.75 6.25 6.25 .75 .62 1.12 .31 .63 .44 3 3.96 2.50 4.84 4.94 4.06 28° ¾ 6.19 7.69 7.69 .94 .62 1.37 .31 .63 .52 4 4.80 2.50 5.92 6.02 4.90 28° Â 7.50 9.12 9.12 1.00 .75 1.50 .31 .75 .65 6 6.90 2.50 8.02 8.12 7.00 28° Â 9.50 11.12 11.12 1.06 .88 1.63 .31 .75 .70 8 9.05 2.50 10.17 10.27 9.15 28° Â 11.75 13.37 13.37 1.12 1.00 1.75 .31 .75 .75 10 11.10 2.50 12.22 12.34 11.20 28° Â 14.00 15.69 15.62 1.19 1.00 1.75 .31 .75 .80 12 13.20 2.50 14.32 14.44 13.30 28° Â 16.25 17.94 17.88 1.25 1.00 1.75 .31 .75 .85 14 15.30 3.50 16.40 16.54 15.44 28° Â 18.75 20.31 20.25 1.31 1.25 2.00 .31 .75 .89 16 17.40 3.50 18.50 18.64 17.54 28° Â 21.00 22.56 22.50 1.38 1.31 2.06 .31 .75 .97 18 19.50 3.50 20.60 20.74 19.64 28° Â 23.25 24.83 24.75 1.44 1.38 2.13 .31 .75 1.05 20 21.60 3.50 22.70 22.84 21.74 28° Â 25.50 27.08 27.00 1.50 1.44 2.19 .31 .75 1.12 24 25.80 3.50 26.90 27.04 25.94 28° Â 30.00 31.58 31.50 1.62 1.56 2.31 .31 .75 1.22 30 32.00 4.00 33.29 33.46 32.17 20° 1¿ 36.88 39.12 39.12 1.81 2.00 2.75 .38 1.00 1.50 36 38.30 4.00 39.59 39.76 38.47 20° 1¿ 43.75 46.00 46.80 2.00 2.00 2.75 .38 1.00 1.80 42 44.50 4.00 45.79 45.96 44.67 20° 1À 50.62 53.12 53.12 2.00 2.00 2.75 .38 1.00 1.95 48 50.80 4.00 52.09 52.26 50.97 20° 1À 57.50 60.00 60.00 2.00 2.00 2.75 .38 1.00 2.20

Tyler: 11910 CR 492 - Tyler, TX 75706 - (800) 527-8478 Anniston: 1501 W. 17th. St. - Anniston, AL 36201 - (800) 226-7601Corona: 1001 ElCamino Ave. - Corona, CA 92879 - (866) 527-8471 Portland: 6204 N. Marine Dr. - Portland, OR 97203 - (866) 527-8471 www.tylerunion.com 61

22U - Mechanical Joint AWWA C110/A21.10

Full Body Revised 08/11

Page 62: :DWHUZRUNV &DWDORJ - McWane

SUBMITTAL (Current revisions for all Standards apply)

SIZES: ............................ 2” through 48” (2” Not Referenced in C153/A21.53)

STANDARDS: ................. ANSI/AWWA C153/A21.53-06 and NFPA 3”-16” UL Listed (EX2111) Note: Cast with tested and traceable ASTM A536 Ductile Iron

PRESSURE RATING: ....... 2”- 24” rated @ 350 psi; 30”- 48” & *fittings with Flanged branches rated @ 250 psi Note: With use of special flange gasket 2”- 24” flanged fittings can be rated @ 350 psi For 350 psi flange joint applications, we recommend the use of annular ring type gasket or comparable. *Note: Compact Wyes over 12” are not pressure rated. Contact manufacturer for rating in your application.

DEFLECTION: .................Fittings 2”- 12” *5° maximum deflection & 14”– 48” *3° maximum deflection Note: If pipe O.D. & fitting I.D. at nominal, achievable deflection is ~50% of maximum

NSF-61: ......................... Meets all requirements, UL Listed (MH16439)

ASPHALTICCOATING: ...................... ANSI/AWWA C104/A21.4-08 - ANSI/AWWA C153

CEMENT LINING: .......... ANSI/AWWA C104.A21.4-08, Double cement lining available

EPOXY COATING:.......... ANSI/AWWA C116/A21.16-09 Note: Fittings are available to the specification(s) required for your application(s)

BARE: ............................. Available

BOLTS: ........................... ANSI/AWWA C111/A21.11-7

INSTALLATION: ............. Per AWWA C600-10 using pipe conforming to ANSI/AWWA C151/A21.51-02 or C900-C905

JOINT DIMENSIONS IN INCHES BOLTS

Size A Dia. B C Dia. D Dia. F Dia. J Dia. K1 Dia. K2 Dia. L M S T X Size No.

3 3.96 2.50 4.84 4.94 4.06 6.19 7.62 7.69 .58 .62 .39 .33 ¾ Á x3 4 4 4.80 2.50 5.92 6.02 4.90 7.50 9.06 9.12 .60 .75 .39 .34 Â ¾x3½ 4 6 6.90 2.50 8.02 8.12 7.00 9.50 11.06 11.12 .63 .88 .43 .36 Â ¾x3½ 6 8 9.05 2.50 10.17 10.27 9.15 11.75 13.31 13.37 .66 1.00 .45 .38 Â ¾x4 6 10 11.10 2.50 12.22 12.34 11.20 14.00 15.62 15.62 .70 1.00 .47 .40 Â ¾x4 8 12 13.20 2.50 14.32 14.44 13.30 16.25 17.88 17.88 .73 1.00 .49 .42 Â ¾x4 8 14 15.30 3.50 16.40 16.54 15.44 18.75 20.31 20.25 .79 1.25 .55 .47 Â ¾x4½ 10 16 17.40 3.50 18.50 18.64 17.54 21.00 22.56 22.50 .85 1.31 .58 .50 Â ¾x4½ 12 18 19.50 3.50 20.60 20.74 19.64 23.25 24.83 24.75 1.00 1.38 .68 .54 Â ¾x4½ 12 20 21.60 3.50 22.70 22.84 21.74 25.50 27.08 27.00 1.02 1.44 .69 .57 Â ¾x4½ 14 24 25.80 3.50 26.90 27.04 25.94 30.00 31.58 31.50 1.02 1.56 .75 .61 Â ¾x5 16 30 32.00 4.00 33.29 33.46 32.17 36.88 39.12 39.12 1.31 2.00 .82 .66 1¿ 1x6 20 36 38.30 4.00 39.59 39.76 38.47 43.75 46.00 46.00 1.45 2.00 1.00 .74 1¿ 1x6 24 42 44.50 4.00 45.79 45.96 44.67 50.62 53.12 53.12 1.45 2.00 1.25 .82 1À 1¼x6½ 28 48 50.80 4.00 52.09 52.26 50.97 57.50 60.00 60.00 1.45 2.00 1.35 .90 1À 1¼x6½ 32

11910 CR 492-Tyler, TX 75706-(800) 527-8478 1501 W. 17th St.-Anniston, AL 36201-(800) 226-76011001 ElCamino Ave.-Corona, CA 92879-(866) 527-8471 6204 N. Marine Dr.-Portland, OR 97203-(866) 527-8471

www.tylerunion.com 62

23U - Mechanical Joint C153/A21.53

CompactRevised 11/11

Page 63: :DWHUZRUNV &DWDORJ - McWane

SUBMITTAL (Current revisions for all Standards apply)

SIZES: ............................ Series 100 for 3” through 24”

STANDARDS: ................. Per ANSI/AWWA C110, C111, and C153; cast with ASTM A536 Ductile Iron. Sizes 3”-12” are recommended for Class 50 through Class 56 ductile pipe Sizes 14”-24” are recommended for Class 53 through Class 56 ductile pipe

DEFLECTION: ................. Maximum recommended deflection of joints is 2° for 3” through 12” and 1° for 14” through 24”

BOLTS: ........................... ANSI/AWWA C111/A21.11-7, for assembly use AWWA C153 length standard T-bolts. The set screws are square headed with Type C knurled cup points, 4140 grade alloy steel that is heat treated to a Rockwell “C” 45/53 case hardness and are shipped assembled in the gland

PRESSURE RATING: ....... Refer to chart provided below

NSF-61: ......................... Meets all requirements, UL Registered

COATING: ..................... ANSI/AWWA C104/A21.4-08 (asphaltic paint that is NSF61 approved)

INSTALLATION: ............. Per Tyler Union instructions below. Note: Not for use on Plain end fittings

T-BOLTS (to secure Gland to Hub) 4” to 24” Retainer gland T-bolts torque to 60 ft lbs

SET SCREWS (to secure Gland to Pipe) Set screw recommended torque value is 75 ft lbs

Tyler:11910 CR 492-Tyler, TX 75706-(800) 527-8478 / Anniston:1501 W. 17th. St.-Anniston, AL 36201-(800) 226-7601 Corona:1001 El Camino Ave.-Corona, CA 92879-(866)527-8471 / Portland: 6204 N. Marine Dr.-Portland, OR 97203-(866) 527-8471

www.tylerunion.com 63

24U-*Mechanical Joint Retainer Gland

Series 100 Revised 06/11

Wash bell and plain end with soapy water, 1. then slip gland and gasket over plain end with the small side of the gasket and ring side of of the gland facing the bell.

2. Slip plain end into bell. Brush soapy water on gasket. This lubricates the gasket and allows it to slip easily into place. Push gasket into bell making sure it is evenly in the bell gasket landing.

3. Slide the gland into position against the back of the gasket. Align bolt holes, insert T-bolts and tighten nuts to finger tight.

4. Snug up all T-bolt nuts evenly. Alternating at 180°, tighten the T-bolt nuts to a torque of: 3” - 60 foot pounds 4” thru 24” - 90 foot pounds.

5. Snug up all set screws evenly. Using a torque wrench, tighten the set screws alternating at 180° to the recommended torque value of 75 foot pounds. If required double check set screws immediately.

Pressure Gland Pipe O.D. D.I. Pipe No of Size of Rating, O.D. O.D. Wall Set Set Gland Wt w/ Size psi B A Class Screws Screws Wt Acces.

3 350 7.69 3.96 50-56 4 Á x2 4 8 4 350 9.12 4.80 50-56 4 Á x2 5 11 6 350 11.12 6.90 50-56 6 Á x2 9 16 8 250 13.37 9.05 50-56 9 Á x2 13 21 10 250 15.62 11.10 50-56 12 Á x2 17 26 12 150 17.88 13.20 50-56 16 Á x2 20 28 14 250 20.25 15.30 53-56 20 Á x2½ 44 55 16 200 22.50 17.40 53-56 24 Á x2½ 54 64 18 200 24.75 19.50 53-56 24 Á x2½ 62 72 20 200 27.00 21.60 53-56 28 Á x3 76 91 24 150 31.50 25.80 53-56 32 Á x3 103 118* Not included in AWWA C110 or AWWA C153

Page 64: :DWHUZRUNV &DWDORJ - McWane

SUBMITTAL (Current revisions for all Standards apply)

SIZES: ...................... For 6” to 12” AWWA C900/905 PVC, Cast Iron, and AWWA C151 Ductile pipe with 4" to 12" side flanged outlet with ¾” tap at branch.

STANDARDS: ........... Mechanical and *Flanged joints comply with ANSI/AWWA C153/A21.53Cast with tested and traceable ASTM A536 Ductile Iron. Ductile Iron Mechanical Joint Tapping Sleeves are produced in accordance with Tyler Union manufacturer’s standard. Dimensions and specification ranges are per the standards provided herein. Note: Recess dimensions are per Manufacturer’s Standardization Society standard practice SP-60. Meets requirements of MSS SP-111

PRESSURE RATING: . 6”- 12” Assemblies rated @ 250 PSI.GASKETS: ................ SBR Mechanical Joint and Split gaskets are per ASTM D2000 - AA and

ANSI/AWWA C111/21.11-7, armor tipped with coiled brass wire spring.NSF-61: ................... Meets all requirementsASPHALTICCOATING: ................ ANSI/AWWA C104/A21.4-08 CEMENT LINING: .... Tapping Sleeves are unlined to ensure

they fit over the pipe being tapped.FLANGE: .................. ANSI Class 125B FLANGE THICKNESS: ANSI/AWWA C153/A21.53-06BOLTS: ..................... ANSI/AWWA C111/A21.11-7DEFLECTION: ........... Deflection is not recommendedINSTALLATION: ....... Per Tyler Union instructions as provided

Tyler:11910 CR 492-Tyler, TX 75706-(800) 527-8478 Anniston: 1501 W. 17th.-St. Anniston, AL 36201-(800) 226-7601

Corona: 1001 El camino Ave.-Corona, CA 92879-(866) 527-8471 Portland: 6204 N. Marine Dr.-Portland, OR 97203-(866) 527-8471 www.tylerunion.com 64

25U-Compact Mechanical Joint

Tapping Sleeve for Ductile Iron, Cast Iron, & C900 PVC Pipe

Revised 11/11

Dimensions Pipe O.D. Range Size A B C D E F Min. Max. DI

6x4 5.016 .250 7.50 15.75 8.00 12.75 6.85 7.15 104 6 7.016 .312 9.50 15.75 8.00 12.75 6.85 7.15 108 8x4 5.016 .250 7.50 16.50 9.00 13.375 9.00 9.35 134 8x6 7.016 .312 9.50 16.50 9.00 13.375 9.00 9.35 140 8 9.016 .312 11.75 16.50 9.00 13.375 9.00 9.35 148 10x4 5.016 .250 7.50 24.00 11.00 20.75 11.04 11.45 236 10x6 7.016 .312 9.50 24.00 11.00 20.75 11.04 11.45 240 10x8 9.016 .312 11.75 24.00 11.00 20.75 11.04 11.45 246 10 11.016 .312 14.25 24.00 11.00 20.75 11.04 11.45 257 12x4 5.016 .250 7.50 26.50 12.00 23.25 13.14 13.56 273 12x6 7.016 .312 9.50 26.50 12.00 23.25 13.14 13.56 286 12x8 9.016 .312 11.75 26.50 12.00 23.25 13.14 13.56 292 12x10 11.016 .312 14.25 26.50 12.00 23.25 13.14 13.56 303 12 13.016 .312 17.00 26.50 12.00 23.25 13.14 13.56 320

Clean pipe, insert side gasket into back 1. half of gasket grooves. Make sure ends are flush with or slightly protrude into the end gasket seating area. Bolt sleeve halves together and trim side 2. gaskets as necessary. MAKE SURE SLEEVE WILL ROTATE FREELY ON PIPE. Install end gaskets, locating cut ends 90° 3. from side gasket If pipe is maximum OD, stretch gasket to make certain cut ends match with no gap in between. Install glands and bolts-rotate sleeve to 4. desired position. Be sure pipe is centered inside the sleeve. Tighten gland bolts alternately, using 80 to 5. 90 foot pounds.After assembly, PRESSURE TEST ALL 6. JOINTS BEFORE TAPPING. If additional tightening is required, release pressure and relax tension on gland bolts before tighten-ing side bolts.

Page 65: :DWHUZRUNV &DWDORJ - McWane

SUBMITTAL (Current revisions for all Standards apply)

SIZES: ...................... 4” through 24”STANDARDS: ........... ANSI/AWWA C153/A21.53-06 and NFPA 4”-16” UL Listed (EX2111)

Note: Cast with tested and traceable ASTM A536 Ductile IronPRESSURE RATING: 350 psi; except for flanged branch fittings and wyes larger than 12"

Note: Flanged branch Non-Wye fittings can be rated @ 350 psi with the use of a special gasket. For 350 psi applications, we recommend annular ring gaskets or comparable. Call for Wye pressure ratings

NSF-61: ................... Meets all requirements, UL Listed (MH16439)ASPHALTICCOATING: ................ ANSI/AWWA C104/A21.4-08 CEMENT LINING: .... ANSI/AWWA C104.A21.4-08 (Double Cement lined Available)EPOXY COATING:.... ANSI/AWWA C116/A21.16-09

Note: Epoxy coated fittings available to the specification(s) in your application BELL SOCKETS: ........ ANSI/AWWA C116/A21.16-09 BOLTS: ..................... ANSI/AWWA C151/A21.51-09 and AWWA C900-97, Table 2BARE: ....................... AvailableDEFLECTION: ........... Fittings 4" - 12", *5 degree maximum & 14" - 24", *3 degree maximum Note: If pipe O.D. & fitting I.D. at nominal, deflection is ~50% of maximum RESTRAINING LUGS:Provided on 16” and smaller fittings and the lug pattern for all sizes

accommodates most gripper-type restraints. Note: Restraining lugs available for 18”- 24” fittings provided sufficient time is available to make pattern adaptations.

INSTALLATION: ....... Per AWWA C600-99 using pipe conforming to ANSI/AWWA C151/A21.51-02 and ANSI/AWWA C900-C905

Tyler Union Waterworks Locations11910 CR 492 - Tyler, TX 75706 - (800) 527-8478 1501 W. 17th St. - Anniston, AL 36201 - (800) 226-76011001 ElCamino Ave. - Corona, CA 92879 - (866) 527-8471 6204 N. Marine Dr. - Portland, OR 97203 - (866) 527-8471 www.tylerunion.com 65

26U - Union TiteTyton Joint - Push On

Compact FittingsRevised 11/11

BELL DIMENSIONS IN INCHES FOR UNION-TITE FITTINGS

Pipe Size A B B.C. C D E

4 5.04 6.38 7.88 4.16 2.25 .35 6 7.14 8.52 10.50 4.29 2.25 .37 8 9.32 10.90 12.88 4.78 2.25 .39 10 11.37 12.91 14.69 4.98 2.25 .41 12 13.47 15.12 17.19 4.98 2.25 .43 14 15.64 18.12 19.00 5.40 2.25 .51 16 17.74 20.32 21.40 5.40 2.25 .52 18 19.83 22.52 ... 5.40 2.25 .59 20 21.94 24.29 ... 5.40 2.25 .60 24 26.14 29.14 ... 5.65 2.50 .62

Page 66: :DWHUZRUNV &DWDORJ - McWane

SUBMITTAL (Current revisions for all Standards apply)

SIZES: ............................ 2” through 48”

STANDARDS: ................. ANSI/AWWA C110/A21.10-08 plus NFPA 3" to 12" UL listed (EX 2111) Note: Cast with tested and traceable ASTM A536 Ductile Iron

PRESSURE RATING: ....... 2” through 48” rated @ 250 psi Note: With the use of special flange gasket 2”through24” flanged fittings can be rated @ 350 psi. For 350 psi flange joint applications, we recommend the use of annular ring type gasket or comparable.

DEFLECTION: ................. Deflection is not recommended for flanged joint fittings due to the rigidity of the joint upon completion of installation.

NSF-61: ......................... Meets all requirements, UL Listed (MH16439)

COATING: ...................... ANSI/AWWA C104.A21.4-08 (Asphaltic or Tnemec Pota Pox 140N-1211)

CEMENT LINING: .......... ANSI/AWWA C104.A21.4-08 (Double Cement lined Available)

EPOXY COATING:.......... ANSI/AWWA C116/A21.16-09 Note: Epoxy coated fittings are available to the specification(s) required for your application(s)

BARE: ............................. Available

FLANGES: ...................... ANSI Class 125 per ASME B16.1 and ANSI/AWWA C111/A21.11-7 Note: *ANSI Class 250 ASME B16.1 flanged fittings available Note: *Due to larger bolt sizing and bolt circle, Class 250 flanges are not compatible with Class 125 flanged fittings. AWWA C110 and AWWA C115 Class 125 flanges are compatible.

FLANGE THICKNESS: .... ANSI/AWWA C151/A21.51-05; Standard Class 125 template for drilling bolt holes Note: Drilling templates are in multiplies of 4, so that fittings may be made to face in any quarter. Bolt holes shall straddle the center line.

BOLTS: ........................... ANSI/AWWA C111/A21.11-7

INSTALLATION: ............. Per AWWA C600-10 using pipe conforming to ANSI/AWWA C151/A21.51-02

Tyler Union Waterworks Locations11910 CR 492 - Tyler, TX 75706 - (800) 527-8478 1501 W. 17th St. - Anniston, AL 36201 - (800) 226-76011001 ElCamino Ave. - Corona, CA 92879 - (866) 527-8471 6204 N. Marine Dr. - Portland, OR 97203 - (866) 527-8471 www.tylerunion.com 66

28U - Flange JointAWWA C110/A21.10

Full Body Revised 11/11

FLANGE DETAILSNominal Dia. of Flange Pipe Size Flange Bolt Thickness Bolt Hole Number Bolt Dia. Inch O.D. Circle T Diameter of Holes & Lengths

2 6 4.75 .62 .75 4 Á x2¼ 3 7.5 6 .75 .75 4 Á x2½ 4 9 7.5 .94 .75 8 Á x3 6 11 9.5 1.00 .875 8 ¾x3½ 8 13.5 11.75 1.12 .875 8 ¾x3½ 10 16 14.25 1.19 1.00 12 Â x4 12 19 17 1.25 1.00 12 Â x4 14 21 18.75 1.38 1.125 12 1x4½ 16 23.5 21.25 1.44 1.125 16 1x4½ 18 25 22.75 1.56 1.25 16 1¿ x5 20 27.5 25 1.69 1.25 20 1¿ x5 24 32 29.5 1.88 1.375 20 1¼x5½ 30 38.75 36 2.12 1.375 28 1¼x6½ 36 46 42.75 2.38 1.675 32 1½x7 42 53 49.50 2.62 1.625 36 1½x7½ 48 59.50 56.00 2.75 1.625 44 1½x8

Page 67: :DWHUZRUNV &DWDORJ - McWane

SUBMITTAL (Current Revisions for All Standards Apply)

SIZES: ............................ Adjustable Slip and Screw type with standard assembled lengths ranging from 19” to 72” (Lengths noted do not include the addition of risers, extensions, and/or bases). See the Catalog or List Price guide for access., lids, rings, bases, risers, meter covers, etc.

STANDARDS: ................. Produced with Class 35 cast iron in accordance with and meeting all applicable terms and provisions of ASTM A-48. All Tyler Union valve boxes when properly installed are suitable for use in conjunction with projects utilizing American Association of State Highway and Transportation Officials (AASHTO) standards and provisions.

INSTALLATION: ............. Per AWWA M44, Manual of Water Supply Practices

COATING: ...................... The asphaltic bituminous coating is applied to a thickness of 1.0 to 1.5 mil and the coating once dry is neither brittle when exposed to cold or sticky when exposed to the sun.

Tyler:11910 CR 492-Tyler,TX 75706-(800) 527-8478 Anniston:1501 W. 17th Street-Anniston, AL 36201-(800) 226-7601 Corona:1001 El Camino Ave.-Corona, CA 92879-(866) 527-8471 Portland: 6204 N. Marine Dr.-Portland, OR 97203-(866) 527-8471 www.tylerunion.com 67

29U-Domestic Heavy Duty Cast Iron Curb, Service,& Valve Boxes + Components

Revised 07/11

6500 SCREW TYPECURB / SERVICE BOX

ExtensionComponets In Inches18T & 27B 30-4218T & 33B 36-4824T & 33B 36-5424T & 39B 42-6030T & 39B 41-64*Enlarged Base Available

6850 SCREW TYPE VALVE BOX

Cast Iron - 2 piece Extension Components Height10T + 15B 19-22 10T + 24B 27-3216T + 24B 27-3716T + 30B 33-4316T + 36B 39-5026T + 30B 36-5226T + 36B 39-6026T + 24B + #60 Ext 51-7126T + 36B + #60 Ext 62-82

6855 SLIP TYPE VALVE BOX

Cast Iron - 2 piece ExtensionComponents Height

10T + 15B 19-2210T + 24B 27-3216T + 24B 27-3716T + 30B 33-4316T + 36B 39-5026T + 30B 36-5226T + 36B 39-6026T + 24B + #60 Ext 51-7126T + 36B + #60 Ext 62-82

6860 SCREW TYPE VALVE BOX

Cast Iron - 3 piece ExtensionComponents) Height10T + 12B 27-3710T + 18B 33-4216T + 24B 39-4916T + 30B 45-5416T + 36B 51-6026T + 30B 45-6626T + 36B 51-72

NOTE: Base Required, Order Separately

7126 SLIP TYPE VALVE BOX

ExtensionComponents Height26T + 24B 28-4826T + 30B 34-5426T + 36B 40-6026T + 24B + #60 Ext 52-7226T + 36B + #60 Ext 60-80

NOTE: Use the 6855 Bottoms with these Tops

For 4” to 12” Valves 5¼” Shaft, Screw Type

For 3” to 20” Valves 5¼” Shaft, Screw Type

For 4” to 12” Valves 5¼” Shaft, Slip Type

For ½” to 2” Curbstops

For 4” to 12” Valves 5¼” Shaft, Slip Type

T = Top

B = Bottom

EXT = Extension

Page 68: :DWHUZRUNV &DWDORJ - McWane

SUBMITTAL (Current revisions for all Standards apply)

SIZES: .........................Adjustable Slip and Screw type with standard assembled lengths ranging from 15” to 72” (Lengths do not include risers, bases, and/or extensions). See the Catalog or List Price guide for acc., lids, rings, bases, risers, meter covers, etc.

STANDARDS: ..............Produced with cast iron in accordance with and meeting all applicable termsand provisions of ASTM A-48. All Tyler Union valve boxes when properlyinstalled are suitable for use in conjunction with projects utilizing American Association of State and Highway Transportation Officials (AASHTO) standards.

INSTALLATION: ..........Per AWWA M44, Manual of Water Supply Practices

COATING: ...................The asphaltic bituminous coating is applied to a thickness of 1.0 to 1.5 mil and the coating once dry is neither brittle when cold or sticky when eposed to the sun.

11910 CR 492-Tyler, TX 75706 - (800) 527-8478 / 1501 W. 17th St.-Anniston, AL - (800) 226-7601 1001 El Camino Ave.-Corona, CA 92879-(866) 527-8471 / 6204 N. Maine Dr.-Portland, OR 97203-(866)527-8471 68 www.tylerunion.com

30U-Non-Domestic *Standard & Heavy Duty Valve & Service Boxes + Components Revised 11/11

6500 SCREW TYPECURB / SERVICE BOX

ExtensionComponets In Inches

12T + 12B 15-2112T + 15B 18-2415T + 15B 21-2715T + 21B 24-3315T + 27B 30-3918T + 27B 30-4218T + 33B 36-4824T + 33B 36-5424T + 39B 42-6030T + 39B 41-64

NOTE: Enlarged Base Available

6850 SCREW TYPE VALVE BOX

Cast Iron - 2 piece Extension Components Height

10T + 15B 19-22 10T + 24B 27-3216T + 24B 27-3716T + 30B 33-4316T + 36B 39-5026T + 30B 36-5226T + 36B 39-6026T + 24B + #60 Ext 51-7126T + 36B + #60 Ext 62-82

6855 SLIP TYPE VALVE BOX

Cast Iron - 2 piece ExtensionComponents Height

10T + 15B 19-2210T + 24B 27-3216T + 24B 27-3716T + 30B 33-4316T + 36B 39-5026T + 30B 36-5226T + 36B 39-6026T + 24B + #60 Ext 51-7126T + 36B + #60 Ext 62-82

6860 SCREW TYPE VALVE BOX

Cast Iron - 3 piece ExtensionComponents) Height

10T + 12B 27-3710T + 18B 33-4216T + 24B 39-4916T + 30B 45-5416T + 36B 51-6026T + 30B 45-6626T + 36B 51-7216T + 24B + #60 Ext 63-7226T + 24B + #60 Ext 63-8426T + 36B + #60 Ext 74-94

NOTE: Base Required, Order Separately

For 4” to 12” Valves 5¼” Shaft, Screw Type

For 3” to 20” Valves 5¼” Shaft, Screw Type

For 4” to 12” Valves 5¼” Shaft, Slip Type

For ½” to 2”Curbstops

T = Top B = Bottom EXT = Extension*Note:Wall thickness of Standard weight boxes is 3/16" and the inside diameter is 1/8" greater than the dimensions provided

Page 69: :DWHUZRUNV &DWDORJ - McWane

SUBMITTAL (Current revisions for all Standards apply)

11910 CR 492 - Tyler,TX 75706 - (800) 527-8478 1501 W. 17th. St. - Anniston, AL 36201 - (800) 226-76011001 ElCamino Ave. - Corona, CA 92879 - (866) 527-8471 6204 N. Marine Dr. - Portland, OR 97203 - (866) 527-8471

www.tylerunion.com 69

31U-Standard Mechanical& Push-On Joint Gaskets

(SBR, NBR, EPDM, Neoprene, FKM)Revised 11/11

Page 1 of 2

Tyler Union Waterworks provides that our *Mechanical and Push-On joint gaskets and dimensions conform to the specifications in ANSI/AWWA C111/A21.11-7 (current revision). Markings include size, mold number, gasket manufacturer's mark, country where molded, and product identification letters. No markings are placed on sealing surfaces per the AWWA C111 standard.

*Note: Push-On and Mechanical Joint transition gasket design standards and markings are not addressed by ANSI/AWWA C111/A21.11-7 (current revision). Transition gaskets provided by Tyler Union follow the material testing standards and specifications established for ANSI/AWWA C111/A21.11-7 gaskets.

Gasket material is vulcanized styrene butadiene rubber (SBR). Purchaser may request special application elastomers (EPDM, Nitrile, Neoprene & FKM) which will be identified on all documentation and corresponding gaskets. Gaskets are free of foreign materials, porous areas, or other defects that make them unfit for the intended use.

Tyler Union gaskets are manufactured under quality control standards and procedures that are maintained by the gasket supplier. Appropriate documentation is maintained by the manufacturer and available for review upon request. Properties and test methods for SBR, EPDM, Nitrile, Neoprene and FKM gaskets are as provided.

Property ASTM Test Method Required Value Hardness, Shore “A” D2240-86 75 (+-5)Minimum Tensile D412-87 1500 psi (10MPa)Minimum Elongation D412-87 150 %Minimum Aging D572-88 60 %Maximum Compression Set D395-89, Method B 20 %Resistance to surface D1149-86 No crackingOzone cracking

Tyler Union's approved suppliers maintain a quality assurance program that is reviewed and updated on an ongoing basis to ensure product quality. Tyler Union's gasket suppliers submit gaskets for testing and provide materials for testing to Underwriters Laboratories, Inc. Tyler Union's gasket providers are recognized under the component program (UL 194/ UL 157) of Underwriters Laboratories, Inc.

Tyler Union provides that our Mechanical and Push-On joint gaskets for potable or wastewater projects will perform as designed when selected per the chart provided and installed per AWWA C600-10.

SBR (Styrene Butadiene rubber)(Buna-S) 20°F to180°F Suitable for Water, Wastewater, most moderate chemicals, wet or Not Recommended for Hydrocarbon Service dry organic acids, alcohols, ketones, and aldehydes

EPDM (Ethylene Propylene) -10°F to 250°F Ideal for water, wastewater, ozone, & strong oxidizing chemicalsNot Recommended for Hydrocarbon Service May be used on steam and air within its temperature range CR (Neoprene) -10°F to 200°F Recommended for moderate chemicals and acids, oil fats, greases, many solvents and air with hydrocarbons. Will not support combustion

NBR (Nytril)(Buna-N)(Hycar) -40°F to 250°F Ideally suited for gasoline, petrolium products, hydrocarbons, water, mineral and vegetable oils

*FKM(Fluoroelastomer) 10°F to 425°F Ideally suited for hydrocarbons, acids, vegetable oils & petrolium*Check with Customer Service for availability

Gasket Types Offered: (1)Mechanical Joint std.(2) Push-On Joint std.(3)Mechanical Joint DUO (4)Mechanical & Push-on Joint Transition(5)Push-on Restraining (6)Mechanical Joint Armor Tip Conductivity(7)Compact tapping Sleeve

Unless other wise requested by the purchaser upon order placement, all gaskets provided will be of our standard SBR material.

Page 70: :DWHUZRUNV &DWDORJ - McWane

31U-Standard Mechanical& Push-On Joint Gaskets

(SBR, NBR, EPDM, Neoprene, FKM)Page 2 of 2

**Mechanical Joint Transition Gasket Dimensions in Inches Pipe A B C D E F G Size ± 0.01" ±1% ± 0.01" ± 0.02"

2 .57 .62 .31 2.28 .16 .24 1.08 3 .70 .62 .31 3.45 .16 .37 1.11 4 .77 .75 .31 4.43 .16 .37 1.26 6 .76 .75 .31 6.53 .16 .36 1.25 8 .82 .75 .31 8.50 .16 .42 1.27 10

12 ** Not Included in AWWA C111. Manufacturers Standard does meet applicable AWWA C111 requirements

.79

.84 .75.75 .31 12.56 .16 .44 1.28

.31 10.59 .16 .39 1.26

Mechanical Joint Gasket Dimensions in Inches Pipe Pipe A B C D E F G Size OD ± 0.01" ±1% ± 0.01% ± 0.01" ± 0.02"

2** 2.50 .48 .62 .31 2.48 .12 .15 1.05 3 3.96 .48 .62 .31 3.86 .12 .15 1.05 4 4.80 .62 .75 .31 4.68 .16 .22 1.22 6 6.90 .62 .75 .31 6.73 .16 .22 1.22 8 9.05 .62 .75 .31 8.85 .16 .22 1.22 10 11.10 .62 .75 .31 10.87 .16 .22 1.22 12 13.20 .62 .75 .31 12.95 .16 .22 1.22 14 15.30 .62 .75 .31 14.99 .16 .22 1.22 16 17.40 .62 .75 .31 17.07 .16 .22 1.22 18 19.50 .62 .75 .31 19.13 .16 .22 1.22 20 21.60 .62 .75 .31 21.20 .16 .22 1.22 24 25.80 .62 .75 .31 25.34 .16 .22 1.22 30 32.00 .73 1.00/*.50 .38/*.50 31.47 .16 .37/*.55 1.54/*1.16

36 38.30 .73 1.00/*.50 .38/*.50 37.67 .16 .37/*.55 1.54/*1.16

42 44.50 .73 1.00/*.50 .38/*.50 43.78 .16 .37/*.55 1.54/*1.16

48 50.80 .73 1.00/*.50 .38/*.50 49.98 .16 .37/*.55 1.54/*1.16

**Not included in AWWA C111. Manufacturer's Standard does meet AWWA C111.

MECHANICAL JOINT GASKETSANSI/AWWA C111/A21.11 *MJ Tru-Lock Gaskets 30 to 48 inch

11910 CR 492 - Tyler,TX 75706 - (800) 527-8478 1501 W. 17th. St. - Anniston, AL 36201 - (800) 226-76011001 ElCamino Ave. - Corona, CA 92879 - (866) 527-8471 6204 N. Marine Dr. - Portland, OR 97203 - (866) 527-8471

www.tylerunion.com 70

Page 71: :DWHUZRUNV &DWDORJ - McWane

11910 CR 492 • Tyler, Texas 75706 • (800) 527-8478 • www.tylerunion.com • 1501 West 17th Street • Anniston, Alabama 36201 • (800) 226-7601 71

1000 Series For Ductile Iron Pipe

1000 SERIES TUF GRIP TLD • DUCTILE PIPE RESTRAINT

Tyler Union’s TUF Grip restraints represent the culmination of 20 years of engineering and testing. As a 3rd generation restraint, TUF Grip is the best available technology in the Waterworks market for use in restraining Ductile Iron Pipe.

TM

UL Listed & FM Approved

SPECIFICATIONSDesigned and proven to restrain ductile iron pipe 3 inches through 48 inches in diameter ¾UL approved for 4 inch thru 24 inch applications ¾FM approved for 4 inch thru 12 inch applications ¾Cast with tested and traceable ASTM A536 compliant 65-45-12 ductile iron. ¾TUF Grip nominal deflection is 3° deflection through 12 inch and 1.5° deflection for 14 inch through 48 inch ¾Wedges are heat treated and hardened to a minimum 370 BHN (Brinel Hardness) ¾Restraint gland and all components are rated and proven for a 2:1 safety factor based on pipe pressure rating ¾Conforms to applicable requirements of ANSI/AWWA C110/A21.10, C111/A21.11, C153/A21.53 ¾Restrains any class of ductile iron pipe conforming to ANSI/AWWA C151/A21.51 ¾Not recommended for use on Plain end fittings ¾

FEATURES • ADVANTAGES

Proven Restraint technology utilizing fewer wedges in frequently applied diameters ¾Fewer wedges equate to less time in the trench and greatly reduced project cost ¾Collar bolts and wedges pivot providing for a stronger engagement of pipe at a lower torque ¾(45 to 60 foot pounds)Wedge Torque nuts twist off within a designed torque range so specialized tools are not required for installation ¾TUF Grip restraints eliminate the need for costly and cumbersome Thrust Blocks and Tie-Rods ¾Larger inside diameter of the gland provides for easier installation on out of round pipe ¾Suitable for Potable and Wastewater applications ¾Allows for disassembly just like a standard mechanical joint ¾TUF Grip ductile iron restraints are color coded black for easy recognition ¾Designed by Harold Kennedy one of the foremost Restraint Engineers in the industry today ¾

“A Proven Third Generation Mechanical Joint Restraint”

MJ TUFGripTM TLD

Torque Nut

ISO 9001-2000 Registered

Page 72: :DWHUZRUNV &DWDORJ - McWane

11910 CR 492 • Tyler, Texas 75706 • (800) 527-8478 • www.tylerunion.com • 1501 West 17th Street • Anniston, Alabama 36201 • (800) 226-7601 72

TUFGrip™ MJ Restraint Dimensions Size

(inches) C D E K2 J K R S

3 4.08 4.88 6.19 7.67 9.82 3/4 2.20 0.86

4 4.93 5.92 7.50 8.98 10.67 7/8 2.20 0.73

6 7.03 8.02 9.50 10.98 12.77 7/8 2.24 0.82

8 9.18 10.17 11.75 13.23 14.92 7/8 2.28 0.82

10 11.23 12.22 14.00 15.70 16.97 7/8 2.37 0.93

12 13.33 14.32 16.25 17.95 19.07 7/8 2.40 0.93

14 15.44 16.40 18.75 20.43 21.18 7/8 2.57 0.91

16 17.54 18.50 21.00 22.88 23.28 7/8 2.57 1.05

18 19.64 20.60 23.25 25.43 25.38 7/8 2.57 1.05

20 21.74 22.70 25.50 27.50 27.48 7/8 2.66 1.15

24 25.94 26.90 30.00 32.00 31.68 7/8 2.72 1.35

30 32.18 33.30 36.88 39.42 39.78 1-1/8 3.86 1.53

36 38.48 39.60 43.75 46.29 46.08 1-1/8 3.86 1.53

42 44.68 45.80 50.62 53.62 53.08 1-3/8 4.56 2.05

48 50.98 52.10 57.50 60.50 59.28 1-3/8 4.56 2.05

1000 Series TLD-Ductile TUFGrip™ Application ChartSize Part # Wedge Bolt Weight Glands Weight Pressure Pipe

(inches) Gland Quantity Quantity (lbs.) (w/ Acc.) Rating (psi) O.D.3 113805 2 4 6.5 10.5 350 3.96

4 113812 2 4 7.1 11.8 350 4.80

6 113829 3 6 11.2 17.8 350 6.90

8 113836 3 6 13.1 20.3 350 9.05

10 113843 6 8 26.0 32.5 350 11.10

12 113850 8 8 31.5 40.4 350 13.20

14 113867 10 10 43.3 53.6 350 15.30

16 113874 12 12 54.1 66.3 350 17.40

18 113898 12 12 59.8 72.2 250 19.50

20 113904 14 14 69.8 83.8 250 21.60

24 113911 16 16 90.4 106.9 250 25.80

30 461289 20 20 248 290 250 32.00

36 461333 24 24 277 327 250 38.30

42 461319 28 28 448 512 250 44.50

48 461326 32 32 519 597 250 50.80

Ductile Pipe Restraint

TM

“Better By Design”

Page 73: :DWHUZRUNV &DWDORJ - McWane

11910 CR 492 • Tyler, Texas 75706 • (800) 527-8478 • www.tylerunion.com • 1501 West 17th Street • Anniston, Alabama 36201 • (800) 226-7601 73

Series 2000 For PVC Pipe

Series 2000 TUF GRIP TLP • PVC PIPE RESTRAINT

Tyler Union’s TUF Grip restraints represent the culmination of 20 years of engineering and testing. As a 3rd generation restraint, TUF Grip is the best available technology in the Waterworks market for use in restraining PVC pipe.

TM

UL Listed & FM Approved

ISO 9001-2000 Registered

Torque Nut

TufGrip™ PVC(TLP)

SPECIFICATIONSDesigned and proven to restrain PVC pipe 3 inches through 36 inches in diameter. ¾UL Listed and FM approved for 4 inch thru 12 inch applications ¾Restrains 3"-12" IPS PVC. For 4"-12" C909 PVCO T-bolt torque is 55-65 ft.lbs. ¾TUF Grip nominal deflection is 3° deflection through 12 inch and 1.5° deflection for 14 inch to 36 inch ¾Cast with tested and traceable ASTM A536 compliant 65-45-12 ductile iron. ¾Restraint gland and all components are rated and proven for a 2:1 safety factor based on pipe pressure rating ¾Conforms to applicable requirements of C110/A21.10, C111/A21.11, C153/A21.53, and ASTM F1674-5 ¾Restrains any class of PVC pipe conforming to AWWA C900/905 ¾

FEATURES • ADVANTAGESProven Restraint technology utilizing fewer wedges in frequently applied diameters ¾Fewer wedges equate to less time in the trench and greatly reduced project cost ¾TUF Grip PVC restraints are color coded red for easy recognition ¾Single tooth contoured wedges reduce pipe wall stress and eliminate point loading of the pipe ¾PVC wedge design maintains pipe hoop strength integrity ¾TUF Grip restraints utilize curved wedges to prevent flattening of the pipe ¾Collar bolts and wedges pivot providing for stronger engagement of pipe at lower torque (45 to 60 ft. pounds) ¾Wedge Torque nuts twist off within a designed torque range so specialized tools are not required for installation ¾TUF Grip restraints eliminate the need for cumbersome Thrust blocks and Tie-Rods ¾Larger inside diameter of the gland provides for easier installation on out of round pipe ¾Proven for use on 4"-12" C909 PVCO pipe at 2:1 safety factor per pipe rating ¾Suitable for Potable and Wastewater applications ¾Allows for disassembly just like a standard mechanical joint. ¾Designed by Harold Kennedy one of the foremost restraint engineers in the industry today ¾

“A Proven Third Generation Mechanical Joint Restraint”

Page 74: :DWHUZRUNV &DWDORJ - McWane

11910 CR 492 • Tyler, Texas 75706 • (800) 527-8478 • www.tylerunion.com • 1501 West 17th Street • Anniston, Alabama 36201 • (800) 226-7601 74

Series 2000 TLP-PVC TUFGrip™ Application ChartSize

(inches)Part #

GlandWedge

QuantityT-Bolt

QuantityWeight(lbs.)

Weight(w/Acc.)

PressureRating (psi)

Pipe O.D.

3 113928 2 4 7.0 11.0 305 3.504 113935 2 4 8.3 12.2 305 4.50-4.806 113942 3 6 12.4 18.3 305 6.63-6.908 113959 3 6 14.9 20.8 305 8.63-9.0510 113973 6 8 25.7 33.4 305 10.75-11.1012 113980 8 8 34.1 42.0 305 12.75-13.2014 113997 10 10 45.1 55.4 235 15.3016 114000 12 12 56.2 68.4 235 17.4018 114017 12 12 62.4 74.8 235 19.5020 114024 14 14 72.9 86.9 235 21.6024 114031 16 16 93.2 109.8 235 25.8030 461302 20 20 251 293 150 32.0036 461357 24 24 281 331 125 38.30

TUFGrip™ MJ Restraint Dimensions Size

(inches) C D E K2 J K R S

3 4.08 4.88 6.19 7.67 9.82 3/4 2.20 0.864 4.93 5.92 7.50 8.98 10.67 7/8 2.20 0.736 7.03 8.02 9.50 10.98 12.77 7/8 2.24 0.828 9.18 10.17 11.75 13.23 14.92 7/8 2.28 0.8210 11.23 12.22 14.00 15.70 16.97 7/8 2.37 0.9312 13.33 14.32 16.25 17.95 19.07 7/8 2.40 0.9314 15.44 16.40 18.75 20.43 21.18 7/8 2.57 0.9116 17.54 18.50 21.00 22.88 23.28 7/8 2.57 1.0518 19.64 20.60 23.25 25.43 25.38 7/8 2.57 1.0520 21.74 22.70 25.50 27.50 27.48 7/8 2.66 1.1524 25.94 26.90 30.00 32.00 31.68 7/8 2.72 1.3530 32.18 33.30 36.88 39.42 39.78 1-1/8 3.86 1.5336 38.48 39.60 43.75 46.29 46.08 1-1/8 3.86 1.53

PVC Pipe Restraint

TM

“Better By Design”

Page 75: :DWHUZRUNV &DWDORJ - McWane

32U ● Series 3000 PVC Bell & Spigot Restraint      For:¹ PVC Pipe to PVC Pipe, ²PVC Pipe           DI Fitting, ³PVC Pipe to Mechanic           Fitting & PVC Pipe to PVC Fitting 

 to Push‐Oal Joint DI 

             For AWWA C900/905 IPS PVC Pipe    Restraint Clamps are Cast with Ductile Iron  SUBMITTAL          (Current Revisions for All Standards Apply)           

IPS●Series 3000●Serrated Clamp       4 Inch thru 12 Inch Sizes DIOD●Series 3000●SerratedClamp 

    PVC ● Pipe Restrainers ● Series 3000 Serrated Clamps Serrated clamp pipe restrainers for restraining C900/C905 PVC and IPS PVC pipe spigot to bellNom Size 

PVC Pipe w/Ductile    Iron Pipe O.D.‐ Series 3000 DIOD 

PVC Pipe w/Steel        Pipe O.D.‐          Series 3000 IPS 

*A 

CMax 

Restraint Rods  Connecting 

Clamping Boltsand Torque in Foot 

Pounds 

~WTLBS.    

  O.D.  Part No.  O.D.  Part No.  Qty Size Qty  Size Torq4  4.80  3000‐4‐DI  4.50  3000‐4‐IPS 9.12 1.12 12.0 2 3/4 x 17 4  5/8 x 3.5 100 15

6  6.90  3000‐6‐DI  6.63  3000‐6‐IPS 11.12 1.12 13.0 2 3/4 x 17 4  5/8 x3.5 100 198  9.05  3000‐8‐DI  8.63  3000‐8‐IPS 14.74 1.28 15.0 2 3/4 x 17 4  3/4 x 5 150 3110  11.10  3000‐10‐DI  10.75  3000‐10‐IPS 16.81 1.42 16.0 4 3/4 x 24 4  7/8 x 5 150 5112  13.20  3000‐12‐DI  12.75  3000‐12‐IPS 19.45 1.42 18.0 4 3/4 x 24 4  7/8 x 5 150 5514  15.30  3000‐14‐DI  N/A N/A  22.54 5.03 24.0 6 3/4 x 30 8  7/8 x 6.5 150 13816  17.40  3000‐16‐DI  N/A N/A  24.66 5.03 28.0 6 3/4 x 30 8  7/8 x 6.5 150 14818  19.50  3000‐18‐DI  N/A N/A  26.64 5.04 28.0 8 3/4 x 30 8  1 x 8 175 20720  21.60  3000‐20‐DI  N/A N/A  28.76 5.04 34.0 8 3/4 x 36 8  1‐1/8 x 8.5 200 26524  25.80  3000‐24‐DI  N/A N/A  33.89 5.08 34.0 12 3/4 x 36 8  1‐1/8 x 8.5 225 40730  32.00  3000‐30‐DI  N/A N/A  40.90  10.00  34.00  12  1 x 40  8  1‐1/8 x 8.5 250 605 36  38.30  3000‐36‐DI  N/A N/A  48.00  10.00  34.00  12  1 x 40  8  1‐1/8 x 8.5 250 670 

Note: *Approximate dimension 

DIOD ● PVC Pipe Restrainers ● Series 3000 Serrated Clamps                 14 Inch thru 36 Inch Sizes

               

   11910 CR 492 ● Tyler, TX 75706 ● (800) 527‐8478 ●       Tyler Union Waterworks     ● 1501 W. 17th Street ● Anniston, AL 36201 ● (800) 226‐7601 6204 N. Marine Dr.●Portland, OR 97203● (866) 527‐8471  www.tylerunion.com     ● 1001 El Camino Ave.● Corona, CA 92879 ● (866) 527‐8471 75 

Page 76: :DWHUZRUNV &DWDORJ - McWane

           

                                                    4” thru 12” Clamp Type                                                                      14” thru 36” Clamp Type

                                                                            Series 3000PO (PVC Pipe to Push‐On DI Fitting)                                                         Series 3000PP (PVC Pipe to PVC Pipe) 

                                                                                                                                                                                                      Series 3000MJ (PVC Pipe to Mechanical Joint DI Fitting)                                     Series 3000PF (PVC Pipe to PVC Fitting) FEATURES and ADVANTAGES: 

  Restraints Rated at the Full Pressure Rating of any class PVC pipe with a 2:1 Safety Factor  Available in Sizes 4” through 36” (Clamps for IPS Pipe available in 4‐12 inch only)  Full 360° Contact, No Pipe Distortion or Point loading  To Ease Installation Restraints and Pipe can be assembled outside the Trench  All Connecting Rods, Hex Nuts, T‐Bolts consist of Low Alloy High Strength Steel and meet ANSI/AWWA C111/A21.11  Clamping bolts are SAE Grade 5 and meet ANSI/AWWA C111/A21.11 requirements  For easy Identification IPS or Steel Pipe O.D. clamps are Grey and DIOD or AWWA C900 clamps are Black 

 SAMPLE SPECIFICATIONS: 

  All sizes of clamps are made of high strength 65‐45‐12 grade of ductile Iron in accordance with the requirements and 

specifications of ASTM A536.   To provide full 360 degree contact with the PVC pipe bell or spigot and support the pipe wall; internal serrations are machined to exact tolerances.  Serrated clamps shall be used to grip the pipe and be capable of being installed bi‐directional.  PVC restraint devices shall have a pressure rating of 2:1 or twice the rating of the PVC pipe on which it is installed.    

ADDITIONAL INFORMATION:  

Can be installed on new or existing systems eliminating the need for thrust blocks  Restraints will work in any type soil and are a guaranteed joint restraint  Restraints work with push on pipe bells  Restraints for IPS pipe sizes available for 4 thru 12 inch pipe only 

 11910 CR 492 ● Tyler, TX 75706 ● (800) 527‐8478 ●       Tyler Union Waterworks     ● 1501 W. 17th Street ● Anniston, AL 36201 ● (800) 226‐7601 6204 N. Marine Dr.●Portland, OR 97203● (866) 527‐8471  www.tylerunion.com     ● 1001 El Camino Ave.● Corona, CA 92879 ● (866) 527‐8471 76 

Page 77: :DWHUZRUNV &DWDORJ - McWane
Page 78: :DWHUZRUNV &DWDORJ - McWane
Page 79: :DWHUZRUNV &DWDORJ - McWane

Certificate of Compliance • Waterworks Division Tyler Union Waterworks manufactures and distributes ductile iron water main fittings with accessories.  Tyler Union 2 inch through 48  inch  fittings  are  cast with  tested  and  traceable ASTM A536  compliant ductile  iron  that  is designed  for use with  and conforms to the all the applicable terms and requirements of ANSI/AWWA C153/A21.53‐06, ANSI/AWWA C151/A21.51,  ANSI/AWWA C115/A21.15, ANSI/AWWA C111/A21.11‐7,  ANSI/AWWA C116/A21.16‐09, ANSI/AWWA C110/A21.10‐08, and ANSI/AWWA C104/A21.4‐08.  Current revisions apply for each noted standard.  

 *Tyler Union ANSI/AWWA C153/A21.53‐06 ductile iron Mechanical and Push‐On joint fittings “2 inch through 24 inch” shall 

 be rated for 350 PSI working pressure and a surge allowance of 100 PSI.  Mechanical and Push‐On joint fittings “30 inch through 48 inch” shall be rated for 250 PSI working pressure and a surge allowance of 100 PSI.   

*Tyler Union ANSI/AWWA C110/A21.10‐08 ductile iron Mechanical joint fittings in “2 inch through 24 inch” shall be rated for 350 PSI working pressure and a surge allowance of 100 PSI.  Mechanical joint fittings “30 inch through 48 inch” shall be rated for 250 PSI working pressure and a surge allowance of 100 PSI.  

 *Tyler Union ANSI/AWWA C110/A21.10‐08 and ANSI/AWWA C153/A21.53‐06 ductile iron Flanged joint fittings in 2 inch 

through  48 inch shall be rated for 250 PSI working pressure and a surge allowance of 100 PSI.  Flange fittings 24 inches (610 millimeters) and smaller may be rated for 350 PSI (2,413 kPa) working pressure with the use of special gaskets.  Per Section A.3 of ANSI/AWWA C110/A21.10‐08 ductile iron Flange joint fittings are not recommended for underground installation due to the rigid design of the fitting flange and joint. 

 *Note – Exceptions:   Mechanical and Push‐On joint fittings with flanged branches are rated for working 

pressure of 250 PSI.  ¹ Flange fittings 24 inches and smaller may be rated for 350 PSI working pressure with the use of special flange gaskets.  ² C153 MJ and Push-on joint  wyes larger than 12 inches are not pressure rated; contact Tyler Union for wye pressure ratings in your application.  ³ For 350 PSI flange joint applications we recommend the use of an annular ring type gasket or comparable. 

 Tyler Union ANSI/AWWA C110/A21.10‐08 and ANSI/AWWA C153/A21.53‐06 ductile iron Mechanical joint fittings and  

ANSI/AWWA C153/A21.53‐06 (manufacturer’s standards) Push‐On joint fittings when installed per AWWA C600‐10 are rated for a *maximum 5 degrees of deflection for “3 inch through 12 inch” fittings and a *maximum 3 degrees of deflection for “14 inch through 48 inch” fittings.  

*Note : The total joint deflection is determined by the O.D. of the pipe and the I.D. of the fitting.  When both the    pipe and the fitting are at nominal; the joint deflection will be approximately 50% of the maximum listed. 

 When required, Tyler Union coated and/or cement lined Potable water ductile iron fittings meet all the applicable terms and 

requirements of ANSI/AWWA C116/A21.16‐09, ANSI/AWWA C104/A21.4‐08, and AWWA C550.  Potable water products manufactured and distributed by Tyler Union Waterworks are National Sanitation Foundation NSF 61 compliant. Current revisions apply for each noted standard.   

 Tyler Union Valve and Service boxes are produced in accordance with and meet all applicable terms and provisions of  

ASTM‐A48.  Cast iron Service and Valve box products when properly selected and installed per the guidelines provided by AWWA M44 (Manual of Water Supply Practices) will provide accessibility for testing and maintenance of a water supply system and will meet the various wheel load designations as provided by the American Association of State Highway Transportation Officials (AASHTO).  

 Tyler Union Mechanical Joint Glands, T‐Bolts, and Nuts are produced in accordance with and will meet all applicable terms 

and provisions of ANSI/AWWA C111/A21.11‐07.  Tyler Union Mechanical and Push‐On joint gaskets are produced in accordance with and will meet all applicable terms and provisions of ANSI/AWWA C111/A21.11‐07.  Tyler Union Mechanical and Push-On joint  Transition gaskets are produced in accordance with Tyler Union's design standards and  will meet all  applicable terms  and  provisions of ANSI/AWWA C111/A21.11‐07. 

 *Tyler Union Waterworks Contact Information* 

            Tyler: 11910 CR 492 ● Tyler, Texas 75706 ● (800) 527‐8478                  Anniston: 1501 W 17th St. ● Anniston, AL 36201 ● (800) 226‐7601   Corona: 1001 El Camino Ave. ●  Corona, CA 92879 ● (866) 527‐8471  Portland: 6204 N. Marine Dr. ● Portland, OR 97203 ● (866) 527‐8471 

www.tylerunion.com 

This document is void if modified in any manner  79

Page 80: :DWHUZRUNV &DWDORJ - McWane

Other TYLER UNION Products IncludeDuctile and PVC Restraint SystemsDuctile Iron C153 Fittings in MJ and Union-TiteDuctile Iron C110 Fittings in MJ and FlangedDuctile Iron Compact Flanged FittingsSwivel MJ Fittings For HydrantsCast Iron Service & Valve Boxes

www.tylerunion.com

SEARCH INVENTORY for all fittings, accessories,valve boxes, companion flanges and other productsin stock, 24 hours a day, 7 days a week.

SEE ENTIRE TYLER UNION CATALOGView, print and download drawings and specifications.

FIND THE COMPLETE LIST PRICE SHEETpage-by-page. Use the index to go to the product group

Distributed By