The above case model has case lengths that are UL and NSF approved. Merchandising Applications Issue Date: 7/15/2013 DX8LD—STRATUS Multi-Deck Capacities Length (FT) Facing Area (FT²) Cubic Capacity (FT³) 4’ 21.30 48.38 8’ 42.60 96.76 12’ 63.97 145.26 Refrigeration Data BTUH per FT of Case Unlighted Shelves LED Lights BTUH per FT of Case Unlighted Shelves T8 Lights Evap. Temp. Discharge Air Parallel Single Parallel Single Temp Velocity 280 302 321 347 +28°F +34°F 185 FPM BTUH determined using EC fan motors. Electrical Data Length ECM Fan Data Light - Amps Anti-Sweat (Vista C) Fan Qty Amps Gelcore LED Optimax Pro Amps 4’ 1 0.10 0.28 0.16 0.85 8’ 2 0.20 0.53 0.33 1.13 12’ 4 0.40 0.82 0.48 1.96 Defrost Data Defrost Per Day Fail Safe Termination Off Cycle 1 45 min +47°F Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main- tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.

DX8LD—STRATUS Multi-Deck - Kysor Warren€™ 21.30 48.38 8’ 42.60 96.76 12’ 63.97 145.26 Refrigeration Data BTUH per FT of Case Unlighted Shelves LED Lights BTUH per FT of Case

Embed Size (px)

Citation preview

Page 1: DX8LD—STRATUS Multi-Deck - Kysor Warren€™ 21.30 48.38 8’ 42.60 96.76 12’ 63.97 145.26 Refrigeration Data BTUH per FT of Case Unlighted Shelves LED Lights BTUH per FT of Case

The above case model has case lengths that are UL and NSF approved.

Merchandising Applications

Issue Date: 7/15/2013DX8LD—STRATUS Multi-Deck

Capacities

Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4’ 21.30 48.38

8’ 42.60 96.76

12’ 63.97 145.26

Refrigeration Data

BTUH per FT of Case Unlighted Shelves

LED Lights

BTUH per FT of Case Unlighted Shelves

T8 LightsEvap. Temp.

Discharge Air

Parallel Single Parallel Single Temp Velocity

280 302 321 347 +28°F +34°F 185 FPM

BTUH determined using EC fan motors. Electrical Data

Length ECM Fan Data Light - Amps Anti-Sweat (Vista C)Fan Qty Amps Gelcore LED Optimax Pro Amps

4’ 1 0.10 0.28 0.16 0.85

8’ 2 0.20 0.53 0.33 1.13

12’ 4 0.40 0.82 0.48 1.96

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 1 45 min +47°F

Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.

Page 2: DX8LD—STRATUS Multi-Deck - Kysor Warren€™ 21.30 48.38 8’ 42.60 96.76 12’ 63.97 145.26 Refrigeration Data BTUH per FT of Case Unlighted Shelves LED Lights BTUH per FT of Case

A Proud Partner of: 5201 Transport Blvd. • Columbus, GA 31907Toll-Free: 800.866.5596 • Phone: 706.568.1514heatcraftrpd.com

2178

1614

6

42

6758

88

AIR

SP

AC

E

3

4178

3478

292927

8

4234

16

30

70

48-1/8 (72-1/4)

42

43

29

24 (36)

712

24 (36)

18

512

96-1/4 (144-1/2)

ELECTRICAL ACCESS POINT

REFRIGERATION PENETRATION

DRAIN CONNECTION(WITH TRAP RIGHT OR LEFT)

FRONT OF CASE

29STUB UPAREA

STANDARD KICKPLATE LOCATION (PLATINUM)

3

3

3912

35

- STANDARD KICKPLATE LOCATION (MODERN, CLASSIC)- OPTIONAL KICKPLATE LOCATION (PLATINUM)

SKIDRAIL

3SKIDRAIL

MINIMUM AIR SPACE

LEG

LEG

LEG

LEG

312 7

3534

714

Add 3” thickness for a pair of ends.

DX8LD Cross View

DX8LD Plan View

Page 3: DX8LD—STRATUS Multi-Deck - Kysor Warren€™ 21.30 48.38 8’ 42.60 96.76 12’ 63.97 145.26 Refrigeration Data BTUH per FT of Case Unlighted Shelves LED Lights BTUH per FT of Case

The above case model has case lengths that are UL and NSF approved.

Merchandising Applications

Issue Date: 12/6/2012DX8LN -- STRATUS Multi-Deck

Capacities

Length Facing Area (FT²) Cubic Capacity (FT³)4’ 21.4 53.66’ 32.1 80.48’ 42.8 107.212’ 64.2 160.8

Refrigeration Data

BTUH per FT of Case

Unlighted Shelves One Row Canopy -

LED Lights

BTUH per FT of Case

Unlighted Shelves One Row Canopy - T8

Lights

Add BTUH per FT per Row

Lighted Shelves

Add BTUH per FT per Row

Nose Lights or Additional T8 Canopy

Light

Evap. Temp.

Discharge Air

Parallel Single Parallel Single LED T8 LED T8 Temp Velocity

1161 1254 1167 1260 11 19 11 19 +26°F +33°F 225 FPMAdd 13 BTUH/FT for additional LED canopy light

Electrical Data

Length ECM Fan Data

Shelf Light - Amps Per

Lighted Shelf

Nose Light - Amps

Canopy Light - Amps

Fan Qty Amps LED T8 LED T8 1 Row

LED2 Row

T84’ 1 0.14 0.12 0.25 0.1 0.25 0.24 0.56’ 2 0.28 0.09 0.22 0.18 0.44 0.37 0.888’ 2 0.28 0.12 0.25 0.2 0.5 0.48 1

12’ 4 0.56 0.12 0.25 0.36 0.75 0.72 1.5

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F

Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.

Page 4: DX8LD—STRATUS Multi-Deck - Kysor Warren€™ 21.30 48.38 8’ 42.60 96.76 12’ 63.97 145.26 Refrigeration Data BTUH per FT of Case Unlighted Shelves LED Lights BTUH per FT of Case

A Proud Partner of:

5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com

DX8LN Cross View

Add 3” thickness for a pair of ends.

DX8LN Plan View

Page 5: DX8LD—STRATUS Multi-Deck - Kysor Warren€™ 21.30 48.38 8’ 42.60 96.76 12’ 63.97 145.26 Refrigeration Data BTUH per FT of Case Unlighted Shelves LED Lights BTUH per FT of Case

The above case model has case lengths that are UL and NSF approved.

Merchandising Applications

Issue Date: 6/21/2013DX8LN (Glycol) — STRATUS Multi-Deck

Capacities

Length Facing Area (FT²) Cubic Capacity (FT³)4’ 21.4 53.6

6’ 32.1 80.4

8’ 42.8 107.2

12’ 64.2 160.8

Refrigeration Data

BTUH per FT of Case

Unlighted Shelves One Row Canopy -

LED Lights

BTUH per FT of Case

Unlighted Shelves One Row Canopy - T8

Lights

Add BTUH per FT per Row

Lighted Shelves

Add BTUH per FT per Row

Nose Lights or Additional T8 Canopy

Light

Evap. Temp.

Discharge Air

Parallel Single Parallel Single LED T8 LED T8 Temp Velocity

1161 1254 1167 1260 11 19 11 19 +26°F +33°F 225 FPM

Add 13 BTUH/FT for additional LED canopy light

Electrical Data

Length ECM Fan Data

Shelf Light - Amps Per

Lighted Shelf

Nose Light - Amps

Canopy Light - Amps

Fan Qty Amps LED T8 LED T8 1 Row

LED2 Row

T84’ 1 0.14 0.12 0.25 0.1 0.25 0.24 0.5

6’ 2 0.28 0.09 0.22 0.18 0.44 0.37 0.88

8’ 2 0.28 0.12 0.25 0.2 0.5 0.48 1

12’ 4 0.56 0.12 0.25 0.36 0.75 0.72 1.5

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 6 35 min +47°F

Glycol Data

Length Heat Load-BTUH Glycol % PG Supply Temp Temp Rise Flow Rate (GPM) Pressure Drop4’ 5,644 35 +20°F +10°F 1.447 2.0 PSI

6’ 8,466 35 +20°F +10°F 2.172 4.40 PSI

8’ 11,288 35 +20°F +10°F 2.895 2.0 PSI

12’ 16,935 35 +20°F +10°F 4.343 4.40 PSI

Type I refrigerator, intended for use in an area where the environ-mental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Re-frigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices with-out incurring obligation.

Page 6: DX8LD—STRATUS Multi-Deck - Kysor Warren€™ 21.30 48.38 8’ 42.60 96.76 12’ 63.97 145.26 Refrigeration Data BTUH per FT of Case Unlighted Shelves LED Lights BTUH per FT of Case

A Proud Partner of: 5201 Transport Blvd. • Columbus, GA 31907Toll-Free: 800.866.5596 • Phone: 706.568.1514heatcraftrpd.com

DX8LN Cross View

Add 3” thickness for a pair of ends.

DX8LN Plan View

Page 7: DX8LD—STRATUS Multi-Deck - Kysor Warren€™ 21.30 48.38 8’ 42.60 96.76 12’ 63.97 145.26 Refrigeration Data BTUH per FT of Case Unlighted Shelves LED Lights BTUH per FT of Case

The above case model has case lengths that are UL and NSF approved.

Merchandising Applications

Issue Date: 7/15/2013DX8UD—STRATUS Multi-Deck

Capacities

Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4’ 22.60 51.32

8’ 45.20 102.64

12’ 67.85 154.00

Refrigeration Data

BTUH per FT of Case Unlighted Shelves

LED Lights Evap. Temp. Discharge Air

Parallel Single Temp Velocity

300 325 +28°F +34°F 185 FPM

BTUH determined using EC Fan Motors. Electrical Data

Length ECM Fan Data Light - Amps Anti-Sweat

(Vista C)Fan Qty Amps Gelcore LED Optimax Pro Amps

4’ 1 0.10 0.16 0.16 0.85

8’ 2 0.20 0.28 0.33 1.13

12’ 4 0.40 0.42 0.48 1.96

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 3 45 min +47°F

Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.

Page 8: DX8LD—STRATUS Multi-Deck - Kysor Warren€™ 21.30 48.38 8’ 42.60 96.76 12’ 63.97 145.26 Refrigeration Data BTUH per FT of Case Unlighted Shelves LED Lights BTUH per FT of Case

A Proud Partner of: 5201 Transport Blvd. • Columbus, GA 31907Toll-Free: 800.866.5596 • Phone: 706.568.1514heatcraftrpd.com

DX8UD Cross View

Add 3” thickness for a pair of ends.

DX8UD Plan View

48-1/8 (72-1/4)

42

43

29

24 (36)

712

24 (36)

18

512

96-1/4 (144-1/2)

ELECTRICAL ACCESS POINT

REFRIGERATION PENETRATION

DRAIN CONNECTION(WITH TRAP RIGHT OR LEFT)

FRONT OF CASE

29STUB UPAREA

STANDARD KICKPLATE LOCATION (PLATINUM)

3

3

3912

35

- STANDARD KICKPLATE LOCATION (MODERN, CLASSIC)- OPTIONAL KICKPLATE LOCATION (PLATINUM)

SKIDRAIL

3SKIDRAIL

MINIMUM AIR SPACE

LEG

LEG

LEG

LEG

312 7

3534

714

Page 9: DX8LD—STRATUS Multi-Deck - Kysor Warren€™ 21.30 48.38 8’ 42.60 96.76 12’ 63.97 145.26 Refrigeration Data BTUH per FT of Case Unlighted Shelves LED Lights BTUH per FT of Case

The above case model has case lengths that are UL and NSF approved.

Merchandising Applications

Issue Date: 11/14/2012DX8UN -- STRATUS Multi-Deck

Capacities

Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 21.4 53.66 32.1 80.48 42.8 107.212 64.2 160.75

Refrigeration Data

BTUH per FT of Case

Unlighted Shelves One Row Canopy -

LED Lights

BTUH per FT of Case

Unlighted Shelves One Row Canopy - T8

Lights

Add BTUH per FT per Row

Lighted Shelves

Add BTUH per FT per Row

Nose Lights or Additional T8 Canopy

Light

Evap. Temp.

Discharge Air

Parallel Single Parallel Single LED T8 LED T8 Temp Velocity 1300 1404 1306 1410 11 19 11 19 +26°F +33°F 200 FPM

Add 13 BTUH/FT for additional LED canopy light

Electrical Data

Length ECM Fan Data

Shelf Light - Amps

Per Lighted Shelf

Canopy Light - Amps

Fan Qty Amps LED T8 1 Row LED

2 Row T8

4’ 1 0.14 0.12 0.25 0.24 0.56’ 2 0.28 0.09 0.22 0.37 0.888’ 2 0.28 0.12 0.25 0.48 112’ 4 0.56 0.12 0.25 0.72 1.5

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F

Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.

Page 10: DX8LD—STRATUS Multi-Deck - Kysor Warren€™ 21.30 48.38 8’ 42.60 96.76 12’ 63.97 145.26 Refrigeration Data BTUH per FT of Case Unlighted Shelves LED Lights BTUH per FT of Case

A Proud Partner of:

5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com

DX8UN Cross View

Add 3” thickness for a pair of ends.

DX8UN Plan View

Page 11: DX8LD—STRATUS Multi-Deck - Kysor Warren€™ 21.30 48.38 8’ 42.60 96.76 12’ 63.97 145.26 Refrigeration Data BTUH per FT of Case Unlighted Shelves LED Lights BTUH per FT of Case

The above case model has case lengths that are UL and NSF approved.

Merchandising Applications

Issue Date: 6/21/2013DX8UN (Glycol) — STRATUS Multi-Deck

Capacities

Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 21.4 53.6

6 32.1 80.4

8 42.8 107.2

12 64.2 160.75

Refrigeration Data

BTUH per FT of Case

Unlighted Shelves One Row Canopy -

LED Lights

BTUH per FT of Case

Unlighted Shelves One Row Canopy - T8

Lights

Add BTUH per FT per Row

Lighted Shelves

Add BTUH per FT per Row

Nose Lights or Additional T8 Canopy

Light

Evap. Temp.

Discharge Air

Parallel Single Parallel Single LED T8 LED T8 Temp Velocity

1300 1404 1306 1410 11 19 11 19 +26°F +33°F 200 FPM

Add 13 BTUH/FT for additional LED canopy light

Electrical Data

Length ECM Fan Data

Shelf Light - Amps

Per Lighted Shelf

Canopy Light - Amps

Fan Qty Amps LED T8 1 Row LED

2 Row T8

4’ 1 0.14 0.12 0.25 0.24 0.5

6’ 2 0.28 0.09 0.22 0.37 0.88

8’ 2 0.28 0.12 0.25 0.48 1

12’ 4 0.56 0.12 0.25 0.72 1.5

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 6 35 min +47°F

Glycol Data

Length Heat Load – BTUH

Glycol % PG

Supply Temp (°F)

Temp Rise (°F)

Flow Rate (GPM)

Pressure Drop (PSI)

4’ 5,224 35 +20 +10 1.145 1.80

6’ 7,836 35 +20 +10 1.717 4.10

8’ 10,448 35 +20 +10 2.290 1.80

12’ 15,672 35 +20 +10 3.434 4.10

Type I refrigerator, intended for use in an area where the environ-mental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Re-frigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices with-out incurring obligation.

Page 12: DX8LD—STRATUS Multi-Deck - Kysor Warren€™ 21.30 48.38 8’ 42.60 96.76 12’ 63.97 145.26 Refrigeration Data BTUH per FT of Case Unlighted Shelves LED Lights BTUH per FT of Case

A Proud Partner of: 5201 Transport Blvd. • Columbus, GA 31907Toll-Free: 800.866.5596 • Phone: 706.568.1514heatcraftrpd.com

DX8UN Cross View

Add 3” thickness for a pair of ends.

DX8UN Plan View

Page 13: DX8LD—STRATUS Multi-Deck - Kysor Warren€™ 21.30 48.38 8’ 42.60 96.76 12’ 63.97 145.26 Refrigeration Data BTUH per FT of Case Unlighted Shelves LED Lights BTUH per FT of Case

The above case model has case lengths that are UL and NSF approved.

Merchandising Applications

Issue Date: 12/6/2012DX8XN -- STRATUS Multi-Deck

Capacities

Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 20.4 53.66 30.6 80.48 40.8 107.212 61.2 160.8

Refrigeration Data

BTUH per FT of Case

Unlighted Shelves One Row Canopy -

LED Lights

BTUH per FT of Case

Unlighted Shelves One Row Canopy - T8

Lights

Add BTUH per FT per Row

Lighted Shelves

Add BTUH per FT per Row

Nose Lights or Additional T8 Canopy

Light

Evap. Temp.

Discharge Air

Parallel Single Parallel Single LED T8 LED T8 Temp Velocity 1085 1172 1091 1178 11 19 11 19 +26°F +33°F 225 FPM

Add 13 BTUH/FT for additional LED canopy light

Electrical Data

Length ECM Fan Data

Shelf Light - Amps Per

Lighted Shelf

Nose Light - Amps

Canopy Light - Amps

Fan Qty Amps LED T8 LED T8 1 Row

LED2 Row

T84’ 1 0.14 0.12 0.25 0.1 0.25 0.24 0.56’ 2 0.28 0.09 0.22 0.18 0.44 0.37 0.888’ 2 0.28 0.12 0.25 0.2 0.5 0.48 1

12’ 4 0.56 0.12 0.25 0.36 0.75 0.72 1.5

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F

Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.

Page 14: DX8LD—STRATUS Multi-Deck - Kysor Warren€™ 21.30 48.38 8’ 42.60 96.76 12’ 63.97 145.26 Refrigeration Data BTUH per FT of Case Unlighted Shelves LED Lights BTUH per FT of Case

A Proud Partner of:

5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com

DX8XN Cross View

Add 3” thickness for a pair of ends.

DX8XN Plan View

Page 15: DX8LD—STRATUS Multi-Deck - Kysor Warren€™ 21.30 48.38 8’ 42.60 96.76 12’ 63.97 145.26 Refrigeration Data BTUH per FT of Case Unlighted Shelves LED Lights BTUH per FT of Case

The above case model has case lengths that are UL and NSF approved.

Merchandising Applications

Issue Date: 6/21/2013DX8XN (Glycol) — STRATUS Multi-Deck

Capacities

Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 20.4 53.6

6 30.6 80.4

8 40.8 107.2

12 61.2 160.8

Refrigeration Data

BTUH per FT of Case

Unlighted Shelves One Row Canopy -

LED Lights

BTUH per FT of Case

Unlighted Shelves One Row Canopy - T8

Lights

Add BTUH per FT per Row

Lighted Shelves

Add BTUH per FT per Row

Nose Lights or Additional T8 Canopy

Light

Evap. Temp.

Discharge Air

Parallel Single Parallel Single LED T8 LED T8 Temp Velocity

1085 1172 1091 1178 11 19 11 19 +26°F +33°F 225 FPM

Add 13 BTUH/FT for additional LED canopy light Electrical Data

Length ECM Fan Data

Shelf Light - Amps Per

Lighted Shelf

Nose Light - Amps

Canopy Light - Amps

Fan Qty Amps LED T8 LED T8 1 Row

LED2 Row

T84’ 1 0.14 0.12 0.25 0.1 0.25 0.24 0.5

6’ 2 0.28 0.09 0.22 0.18 0.44 0.37 0.88

8’ 2 0.28 0.12 0.25 0.2 0.5 0.48 1

12’ 4 0.56 0.12 0.25 0.36 0.75 0.72 1.5

Defrost Data

Defrost Per Day Fail Safe TerminationOff Cycle 6 35 min +47°F

Glycol Data

Length Heat Load-BTUH Glycol % PG Supply Temp Temp Rise Flow Rate (GPM) Pressure Drop4’ 5,276 35 +20°F +10°F 1.353 1.90 PSI

6’ 7,914 35 +20°F +10°F 2.030 4.10 PSI

8’ 10,552 35 +20°F +10°F 2.705 1.90 PSI

12’ 15,828 35 +20°F +10°F 4.060 4.10 PSI

Type I refrigerator, intended for use in an area where the environ-mental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Re-frigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices with-out incurring obligation.

Page 16: DX8LD—STRATUS Multi-Deck - Kysor Warren€™ 21.30 48.38 8’ 42.60 96.76 12’ 63.97 145.26 Refrigeration Data BTUH per FT of Case Unlighted Shelves LED Lights BTUH per FT of Case

A Proud Partner of: 5201 Transport Blvd. • Columbus, GA 31907Toll-Free: 800.866.5596 • Phone: 706.568.1514heatcraftrpd.com

DX8XN Cross View

Add 3” thickness for a pair of ends.

DX8XN Plan View