12
©2011 DENTIS CO.,LTD. All Right reserved. Specifications are subject to change without notice Trademarks are the property of DENTIS CO.,LTD. or their respective owners Issued date : 1 st of December, 2011 Version : Rev.201112-1A Headquarters #951. Woram-Dong, Dalseo-Gu, Daegu, Korea / Tel. +82-53-583-2804~5 Fax. +82-53-583-2806 www.dentis.co.kr Sales Head Office(Seoul) #907-908, Leaders Tower 60 -15, Gasan-Dong Geumcheon-Gu Seoul, Korea DENTIS USA 5455 Wilshire Blvd #950 LA CA 90036 / Tel. +1-323-677-4363~5 Fax. +1-323-677-4366 DENTIS TAIWAN 11F-2, No.65, Songde Rd., Xinyi Dist., Taipei City 110, Taiwan / Tel : + 886-2-2729-6200

e-Clean System

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

©2011 DENTIS CO.,LTD.All Right reserved.Specifications are subject to change without noticeTrademarks are the property of DENTIS CO.,LTD. or their respective owners

Issued date : 1st of December, 2011Version : Rev.201112-1A

Headquarters#951. Woram-Dong, Dalseo-Gu, Daegu, Korea / Tel. +82-53-583-2804~5 Fax. +82-53-583-2806 www.dentis.co.kr

Sales Head Office(Seoul)#907-908, Leaders Tower 60 -15, Gasan-Dong Geumcheon-Gu Seoul, Korea

DENTIS USA5455 Wilshire Blvd #950 LA CA 90036 / Tel. +1-323-677-4363~5 Fax. +1-323-677-4366

DENTIS TAIWAN11F-2, No.65, Songde Rd., Xinyi Dist., Taipei City 110, Taiwan / Tel : + 886-2-2729-6200

e-Clean System

e-Clean System

DENTAL IMPLANT SOLUTIONC o n t e n t s• A Multi-Center Retrospective Study of DENTIS Implant System····3p

• Features of CLEANLANT······················4p

• Fixture System Selection······················5p

• Prosthetic Flow Diagrams for e-Clean·················6p

• Prosthetic Components·······················8p

• Cleanlant Surgical Kit························10p

A Multi-Center Retrospective Study of DENTIS Implant System

Background: The design of DENTIS implant system, marketed since 2005 in Korea and abroad in 15 countries, is designed with the following characteristics: RBM surface treatments for time-proven osseo-integration; tapered body with optimized thread designs for easy initial fixation at the time of placement surgery; 3 different abutment connection types for the same body design, allowing easier transition for the operator from existing systems in his/her armamentarium; and simplified prosthetic components. The purpose of this retrospective study was to evaluate clinical success rates for a new dental implant system called DENTIS in various private practice clinical settings.

Methods: 707 consecutive patients at 3 different clinical locations were treated with 1429 DENTIS implants. All 3 different abutment connection types of DENTIS Implant System (external hex connection type, octagonal conical-taper internal supra-gingival connection type, and submerged/bone level hex conical-taper internal connection type) were utilized in this study based on operator decision for each case. Implants were placed at various locations throughout the maxilla and mandible according to the treatment plan, including delayed and immediate placements after extractions. Various bone grafting procedures were done, including sinus augmentations, when clinically necessary. Patients were recalled and clinically examined at regular intervals along with radiographs to monitor clinical progression and prosthetic serviceability and stability.

Results: Average time since implant placements were

26 months. Average time since delivery of prosthesis

was 21 months. 27 implants out of 1429 implants had

to be removed before delivery of definitive restorations

for various clinical failure criteria, resulting in a failure

rate of 1.9%. Cumulative survival rate was 98.1%.

Average age of the patient population was 52 years

old at the time of implant placement surgery, while

youngest patient was 16 years old and oldest patient

was 87 years old. 52.7% of the patient population

was female, while 47.3% was male. While maxillary

molar region had the highest risk of failures

anatomically, diabetes and smoking were the highest

medical condition risk factors. Prosthetic complication

factors such as screw loosening, cemented crowns

coming-off, and porcelain fractures affected 36

implants, resulting in 4.8% prosthetic complication

rate for the 26 months of this study.

Conclusion: A new dental implant system called

DENTIS is found to be performing well in various

clinical practice settings in this retrospective multi-

center study. Cumulative success rate of 98.1% for

the DENTIS Implant System, as demonstrated in this

study, compares favorably to most of the leading

implant systems in the market now. Same patient

population will continue be followed up in coming

years for further evaluation of DENTIS implants.

Thomas K. Lee, DDS

Su-Kwan Kim, DDS, PhD

Sang-Don Joo, DDS

Sang-Chul Ko, DDS

● Age Distribution

● Anatomic Locations ● Failure Anatomic Sites

● Failure Details / Factors

● Prosthetic Complications

● DENTIS Implant Success Rate

● Failures

● Recipients

500

400

300

200

100

0‹20 20-29 30-39 40-49 50-59 60-69 70-79 ›80

Female53%

Male47%

600

500

400

300

200

100

0Upper

AnteriorUpper

PremolarUpperMolar

LowerAnterior

LowerPremolar

LowerMolar

Failure2%

Success98%

Female37%

Male63%

12

10

8

6

4

2

0Upper

AnteriorUpper

PremolarUpperMolar

LowerAnterior

LowerPremolar

LowerMolar

0 5 10 15

Smoker

Diabetes

Hypertension

Short Implant(›10mm)

Narrow Implant(‹4mm)

Sinus Graft Sx

Bone Graft

Dentis e-Clean System I A Multi-Center Retrospective Study of DENTIS Implant System I •02 ••03

Fixture Mount can be used for Imperssion Coping and Free Abutment.Fixture mount is economical and makes it simple for dental prosthetics.

Mount could be used as transfer type of impression coping and final

abutment after inserted fixture.

Tapered designRoot Form Design achieved superb initial fixation strength also in places

where condition of the bone is not good, makes an easy and stable

surgery possible and reduces surgery time.

Micro-Thread for Bone Loss PreventionIt prevents water absorption of the cortex due to bacterial infection and

minimizes bone loss, breaking due to internal stress and stimulus of the

cortical bone with stable initial fixation strength and wedges in thin cortex

as well.

Safe cutting edgeIt minimizes resistance of the bone during insertion of the implant and

functions to provide safe and smooth insertion.

RBM Surface Treatment (1.5±0.2um)It maximizes osseointegration.

× 50

× 5,000

Features of CLEANLANT

Mini

ImplantDiameter

Length Code

Ø3.5

8.0mm DEFM3508

10.0mm DEFM3510

12.0mm DEFM3512

14.0mm DEFM3514

Regular

ImplantDiameter

Length Code

Ø4.1

8.0mm DEFR4108

10.0mm DEFR4110

12.0mm DEFR4112

14.0mm DEFR4114

Wide

ImplantDiameter

Length Code

Ø5.1

8.0mm DEFW5108

10.0mm DEFW5110

12.0mm DEFW5112

14.0mm DEFW5114

0.7㎜

Ø3.5

L

Hex 2.4

Ø4.1

0.7㎜

L

Hex 2.7

Ø5.1

0.7㎜

L

Hex 3.4

Fixture System Selection

Dentis e-Clean System I Fixture System Selection I •04 ••05

Description Flow Tool

Screw

Abutment 1) Cemented2) Angled3) Gold UCLA4)Plastic

Lab analog

Impression Coping1) Pick-up2) Transfer

1) Cover Screw2) Healing Abutment

E-Clean Fixture

1

1 2 3 4

2

1.2 Hex Driver

1.2 Hex Driver

Hex 15˚ Hex

Hex

HexN-Hex 25˚ N-Hex

N-Hex

N-Hex

Cemented system

1 2

1.2 Hex Driver0.9 Hex Driver※Mini Only

Prosthetic Flow Diagrams for e-Clean

Description Flow Tool

1) O-Ring2) O-Ring Retainer

O-Ring Lab Analog

O-Ring Abutment

1) Cover Screw2) Healing Abutment

E-Clean Fixture

2

O-Ring system

O-RingAbutment Driver

1

1.2 Hex Driver0.9 Hex Driver※Mini Only

1 2

Dentis e-Clean System I Prosthetic Flow Diagrams for e-Clean I •06 ••07

e-Clean Cemented Abutment Components

Mount Platform Diameter Code No.

MiniRegular

Wide

DEFMMDEFMRDEFMW

Short Mount Platform Diameter Code No.

MiniRegular

Wide

DEFMSMDEFMSRDEFMSW

6.5mm

Cover Screw Platform Diameter Code No.

MiniRegular

Wide

DECSMDECSRDECSW

Cemented Abutment Type Cuff Height(H) Code No.

Hex

N-Hex

1mm2mm3mm4mm1mm2mm3mm4mm

1mm2mm3mm4mm1mm2mm3mm4mm

6mm

8mm

6mm

8mm

MiniDECAM416HDECAM426HDECAM436HDECAM446HDECAM418HDECAM428HDECAM438HDECAM448H

DECAM416NDECAM426NDECAM436NDECAM446NDECAM418NDECAM428NDECAM438NDECAM448N

DECAR516HDECAR526HDECAR536HDECAR546HDECAR518HDECAR528HDECAR538HDECAR548H

DECAR516NDECAR526NDECAR536NDECAR546NDECAR518NDECAR528NDECAR538NDECAR548N

DECAR616HDECAR626HDECAR636HDECAR646HDECAR618HDECAR628HDECAR638HDECAR648H

DECAR616NDECAR626NDECAR636NDECAR646NDECAR618NDECAR628NDECAR638NDECAR648N

WideDECAW616HDECAW626HDECAW636HDECAW646HDECAW618HDECAW628HDECAW638HDECAW648H

DECAW616NDECAW626NDECAW636NDECAW646NDECAW618NDECAW628NDECAW638NDECAW648N

Regular

* Abutment+Abutment Screw Set Code : Abutment Code + S(ex: DECAM416HS)

Cuff: 1, 2, 3, 4mm

H

Hex

N-Hex

Lab Analog Platform Diameter Code No.

MiniRegular

Wide

DELAMDELARDELAW

Impression Coping - Transfer Type Code No.

HexN-Hex

MiniDETIM40HDETIM40N

DETIR50HDETIR50N

DETIR60HDETIR60N

WideDETIW60HDETIW60N

Regular

* Impression Coping+Guide Pin Set Code : Impression Coping Code + S(ex: DETIM40HS)

Hex N-Hex

Impression Coping - Pick-Up Type Code No.

HexN-Hex

MiniDEIM40HDEIM40N

DEIR50HDEIR50N

DEIR60HDEIR60N

WideDEIW60HDEIW60N

Regular

* Impression Coping+Guide Pin Set Code : Impression Coping Code + S(ex: DEIM40HS)

Healing Abutment Cuff Code No.

2mm3mm4mm

5.5mm7mm

MiniDEHM420DEHM430DEHM440DEHM455DEHM470

DEHR520DEHR530DEHR540DEHR555DEHR570

DEHR620DEHR630DEHR640DEHR655DEHR670

WideDEHW620DEHW630DEHW640DEHW655DEHW670

Regular

Cuff: 2, 3, 4, 5.5, 7mm

Prosthetic Components

e-Clean O-Ring Abutment Components

O-Ring Code No.

ORING

O-Ring Lab Analog Code No.

DOLA

O-Ring Retainer Code No.

DOR

O-Ring Abutment Platform Diameter Cuff Code No.Ø4.1

Ø5.1

2mm4mm

2mm4mm

DEORRA20DEORRA40

DEORWA20DEORWA40

Cuff: 2, 4mm

Temporary Abutment Platform Diameter Type Code No.Ø4.0Ø4.5Ø5.5Ø4.0Ø4.5Ø5.5Ø4.0Ø4.5Ø5.5Ø4.0Ø4.5Ø5.5

TitaniumHex

TitaniumN-Hex

PeekHex

PeekN-Hex

DETMHDETRHDETWHDETMNDETRNDETWN

DEPTMHDEPTRHDEPTWHDEPTMNDEPTRNDEPTWN

* Abutment+Abutment Screw Set Code : Abutment Code + S(ex: DETMHS)

Titanium

Hex

Hex

N-Hex

N-Hex

Plastic

Plastic UCLA Type Code No.

HexN-Hex

MiniDEPMHDEPMN

RegularDEPRHDEPRN

WideDEPWHDEPWNHex N-Hex

* Abutment+Abutment Screw Set Code : Abutment Code + S(ex: DEPMHS)

Gold UCLA Type Code No.

HexN-Hex

MiniDEGUMHDEGUMN

RegularDEGURHDEGURN

WideDEGUWHDEGUWNHex N-Hex

* Abutment+Abutment Screw Set Code : Abutment Code + S(ex: DEPMHS)

Angled Abutment Angle Cuff Height(H) Code No.

15˚

25˚

2mm4mm

2mm4mm

8mm

8mm

MiniDEAAM4215DEAAM4415

DEAAM4225DEAAM4425

DEAAR5215DEAAR5415

DEAAR5225DEAAR5425

DEAAR6215DEAAR6415

DEAAR6225DEAAR6425

WideDEAAW6215DEAAW6415

DEAAW6225DEAAW6425

Regular

* Abutment+Abutment Screw Set Code : Abutment Code + S(ex: DEAAM4215S)

15。 25。

Cuff: 2, 4mm

Dentis e-Clean System I Prosthetic Components I •08 ••09

e-Clean Tapered countersink

Twist Drill

Ø3.5

Ø0.9

Ø1.2

Ø4.1

Ø5.1

DTD3508DTD3510

DTD3512DTD3514

DRD09

DRD12S DRD12L

DTD4108DTD4110

DTD4112DTD4114

DTD5108DTD5110

DTD5112DTD5114

Ø3.5

Ø3.5

Ø4.1

Ø4.1

Ø3.5

DETCS35

Mini

DEFMSM

DMHD24

Ø4.1

DETCS41

Regular

DEFMSR

DMHD30

Ø5.1

DETCS51

Wide

DEFMSW

Code - DEK

05

06

07

08

01

02

04

03

09

10

1412

13

01 0503 04 06 07 08 09

02

12

13

10

11

14

Pilot Drill

Drill Extension

StraightTwist Drill

Mount Driverfor Machine

Short Mount

Hex Driver

Ø2.2

DTD2208DTD2210

DTD2212DTD2214

DTD2808DTD2810

DTD2812DTD2814

DSPD28

Ø2.8

Mount Driverfor Ratchet

DRHDS24 DRHDL24

DRHDS30 DRHDL30

Parallel Pin

DPPØ2.8DPD

DDE

Point Drill

DPDG

Torque RatchetProbe Depth Gauge

DTR

e - Clean tapered KIT

Ø3.5 Fixture D4 Bone Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø3.5 fixture D2-3 Bone Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø3.5 tapered drill → Ø3.5 countersink →Ø3.5 fixture D1 Bone Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø3.5 tapered drill → Ø3.5 countersink →Ø3.5 tap drill (option) → Ø3.5 fixture

Ø4.1 Fixture D4 Bone Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø3.5 tapered drill →Ø4.1 fixture D2-3 Bone Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø3.5 tapered drill →Ø4.1 tapered drill →Ø4.1 countersink →Ø4.1 fixture D1 Bone Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø3.5 tapered drill →Ø4.1 tapered drill →Ø4.1 countersink →Ø4.1 tap drill (option) → Ø4.1 fixture

Ø5.1 Fixture D4 Bone Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø3.5 tapered drill →Ø4.1 tapered drill →Ø5.1 fixture D2-3 Bone Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø3.5 tapered drill →Ø4.1 tapered drill → Ø5.1 tapered drill →Ø5.1 countersink →Ø5.1 fixture D1 Bone Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø3.5 tapered drill →Ø4.1 tapered drill → Ø5.1 tapered drill →Ø5.1 countersink →Ø5.1 tap drill (option) →Ø5.1 fixture

Drilling Sequence

Cleanlant Surgical Kit

11

www.dentis.co.kr