©2011 DENTIS CO.,LTD.All Right reserved.Specifications are subject to change without noticeTrademarks are the property of DENTIS CO.,LTD. or their respective owners
Issued date : 1st of December, 2011Version : Rev.201112-1A
Headquarters#951. Woram-Dong, Dalseo-Gu, Daegu, Korea / Tel. +82-53-583-2804~5 Fax. +82-53-583-2806 www.dentis.co.kr
Sales Head Office(Seoul)#907-908, Leaders Tower 60 -15, Gasan-Dong Geumcheon-Gu Seoul, Korea
DENTIS USA5455 Wilshire Blvd #950 LA CA 90036 / Tel. +1-323-677-4363~5 Fax. +1-323-677-4366
DENTIS TAIWAN11F-2, No.65, Songde Rd., Xinyi Dist., Taipei City 110, Taiwan / Tel : + 886-2-2729-6200
DENTAL IMPLANT SOLUTIONC o n t e n t s• A Multi-Center Retrospective Study of DENTIS Implant System····3p
• Features of CLEANLANT······················4p
• Fixture System Selection······················5p
• Prosthetic Flow Diagrams for e-Clean·················6p
• Prosthetic Components·······················8p
• Cleanlant Surgical Kit························10p
A Multi-Center Retrospective Study of DENTIS Implant System
Background: The design of DENTIS implant system, marketed since 2005 in Korea and abroad in 15 countries, is designed with the following characteristics: RBM surface treatments for time-proven osseo-integration; tapered body with optimized thread designs for easy initial fixation at the time of placement surgery; 3 different abutment connection types for the same body design, allowing easier transition for the operator from existing systems in his/her armamentarium; and simplified prosthetic components. The purpose of this retrospective study was to evaluate clinical success rates for a new dental implant system called DENTIS in various private practice clinical settings.
Methods: 707 consecutive patients at 3 different clinical locations were treated with 1429 DENTIS implants. All 3 different abutment connection types of DENTIS Implant System (external hex connection type, octagonal conical-taper internal supra-gingival connection type, and submerged/bone level hex conical-taper internal connection type) were utilized in this study based on operator decision for each case. Implants were placed at various locations throughout the maxilla and mandible according to the treatment plan, including delayed and immediate placements after extractions. Various bone grafting procedures were done, including sinus augmentations, when clinically necessary. Patients were recalled and clinically examined at regular intervals along with radiographs to monitor clinical progression and prosthetic serviceability and stability.
Results: Average time since implant placements were
26 months. Average time since delivery of prosthesis
was 21 months. 27 implants out of 1429 implants had
to be removed before delivery of definitive restorations
for various clinical failure criteria, resulting in a failure
rate of 1.9%. Cumulative survival rate was 98.1%.
Average age of the patient population was 52 years
old at the time of implant placement surgery, while
youngest patient was 16 years old and oldest patient
was 87 years old. 52.7% of the patient population
was female, while 47.3% was male. While maxillary
molar region had the highest risk of failures
anatomically, diabetes and smoking were the highest
medical condition risk factors. Prosthetic complication
factors such as screw loosening, cemented crowns
coming-off, and porcelain fractures affected 36
implants, resulting in 4.8% prosthetic complication
rate for the 26 months of this study.
Conclusion: A new dental implant system called
DENTIS is found to be performing well in various
clinical practice settings in this retrospective multi-
center study. Cumulative success rate of 98.1% for
the DENTIS Implant System, as demonstrated in this
study, compares favorably to most of the leading
implant systems in the market now. Same patient
population will continue be followed up in coming
years for further evaluation of DENTIS implants.
Thomas K. Lee, DDS
Su-Kwan Kim, DDS, PhD
Sang-Don Joo, DDS
Sang-Chul Ko, DDS
● Age Distribution
● Anatomic Locations ● Failure Anatomic Sites
● Failure Details / Factors
● Prosthetic Complications
● DENTIS Implant Success Rate
● Failures
● Recipients
500
400
300
200
100
0‹20 20-29 30-39 40-49 50-59 60-69 70-79 ›80
Female53%
Male47%
600
500
400
300
200
100
0Upper
AnteriorUpper
PremolarUpperMolar
LowerAnterior
LowerPremolar
LowerMolar
Failure2%
Success98%
Female37%
Male63%
12
10
8
6
4
2
0Upper
AnteriorUpper
PremolarUpperMolar
LowerAnterior
LowerPremolar
LowerMolar
0 5 10 15
Smoker
Diabetes
Hypertension
Short Implant(›10mm)
Narrow Implant(‹4mm)
Sinus Graft Sx
Bone Graft
Dentis e-Clean System I A Multi-Center Retrospective Study of DENTIS Implant System I •02 ••03
Fixture Mount can be used for Imperssion Coping and Free Abutment.Fixture mount is economical and makes it simple for dental prosthetics.
Mount could be used as transfer type of impression coping and final
abutment after inserted fixture.
Tapered designRoot Form Design achieved superb initial fixation strength also in places
where condition of the bone is not good, makes an easy and stable
surgery possible and reduces surgery time.
Micro-Thread for Bone Loss PreventionIt prevents water absorption of the cortex due to bacterial infection and
minimizes bone loss, breaking due to internal stress and stimulus of the
cortical bone with stable initial fixation strength and wedges in thin cortex
as well.
Safe cutting edgeIt minimizes resistance of the bone during insertion of the implant and
functions to provide safe and smooth insertion.
RBM Surface Treatment (1.5±0.2um)It maximizes osseointegration.
× 50
× 5,000
Features of CLEANLANT
Mini
ImplantDiameter
Length Code
Ø3.5
8.0mm DEFM3508
10.0mm DEFM3510
12.0mm DEFM3512
14.0mm DEFM3514
Regular
ImplantDiameter
Length Code
Ø4.1
8.0mm DEFR4108
10.0mm DEFR4110
12.0mm DEFR4112
14.0mm DEFR4114
Wide
ImplantDiameter
Length Code
Ø5.1
8.0mm DEFW5108
10.0mm DEFW5110
12.0mm DEFW5112
14.0mm DEFW5114
0.7㎜
Ø3.5
L
Hex 2.4
Ø4.1
0.7㎜
L
Hex 2.7
Ø5.1
0.7㎜
L
Hex 3.4
Fixture System Selection
Dentis e-Clean System I Fixture System Selection I •04 ••05
Description Flow Tool
Screw
Abutment 1) Cemented2) Angled3) Gold UCLA4)Plastic
Lab analog
Impression Coping1) Pick-up2) Transfer
1) Cover Screw2) Healing Abutment
E-Clean Fixture
1
1 2 3 4
2
1.2 Hex Driver
1.2 Hex Driver
Hex 15˚ Hex
Hex
HexN-Hex 25˚ N-Hex
N-Hex
N-Hex
Cemented system
1 2
1.2 Hex Driver0.9 Hex Driver※Mini Only
Prosthetic Flow Diagrams for e-Clean
Description Flow Tool
1) O-Ring2) O-Ring Retainer
O-Ring Lab Analog
O-Ring Abutment
1) Cover Screw2) Healing Abutment
E-Clean Fixture
2
O-Ring system
O-RingAbutment Driver
1
1.2 Hex Driver0.9 Hex Driver※Mini Only
1 2
Dentis e-Clean System I Prosthetic Flow Diagrams for e-Clean I •06 ••07
e-Clean Cemented Abutment Components
Mount Platform Diameter Code No.
MiniRegular
Wide
DEFMMDEFMRDEFMW
Short Mount Platform Diameter Code No.
MiniRegular
Wide
DEFMSMDEFMSRDEFMSW
6.5mm
Cover Screw Platform Diameter Code No.
MiniRegular
Wide
DECSMDECSRDECSW
Cemented Abutment Type Cuff Height(H) Code No.
Hex
N-Hex
1mm2mm3mm4mm1mm2mm3mm4mm
1mm2mm3mm4mm1mm2mm3mm4mm
6mm
8mm
6mm
8mm
MiniDECAM416HDECAM426HDECAM436HDECAM446HDECAM418HDECAM428HDECAM438HDECAM448H
DECAM416NDECAM426NDECAM436NDECAM446NDECAM418NDECAM428NDECAM438NDECAM448N
DECAR516HDECAR526HDECAR536HDECAR546HDECAR518HDECAR528HDECAR538HDECAR548H
DECAR516NDECAR526NDECAR536NDECAR546NDECAR518NDECAR528NDECAR538NDECAR548N
DECAR616HDECAR626HDECAR636HDECAR646HDECAR618HDECAR628HDECAR638HDECAR648H
DECAR616NDECAR626NDECAR636NDECAR646NDECAR618NDECAR628NDECAR638NDECAR648N
WideDECAW616HDECAW626HDECAW636HDECAW646HDECAW618HDECAW628HDECAW638HDECAW648H
DECAW616NDECAW626NDECAW636NDECAW646NDECAW618NDECAW628NDECAW638NDECAW648N
Regular
* Abutment+Abutment Screw Set Code : Abutment Code + S(ex: DECAM416HS)
Cuff: 1, 2, 3, 4mm
H
Hex
N-Hex
Lab Analog Platform Diameter Code No.
MiniRegular
Wide
DELAMDELARDELAW
Impression Coping - Transfer Type Code No.
HexN-Hex
MiniDETIM40HDETIM40N
DETIR50HDETIR50N
DETIR60HDETIR60N
WideDETIW60HDETIW60N
Regular
* Impression Coping+Guide Pin Set Code : Impression Coping Code + S(ex: DETIM40HS)
Hex N-Hex
Impression Coping - Pick-Up Type Code No.
HexN-Hex
MiniDEIM40HDEIM40N
DEIR50HDEIR50N
DEIR60HDEIR60N
WideDEIW60HDEIW60N
Regular
* Impression Coping+Guide Pin Set Code : Impression Coping Code + S(ex: DEIM40HS)
Healing Abutment Cuff Code No.
2mm3mm4mm
5.5mm7mm
MiniDEHM420DEHM430DEHM440DEHM455DEHM470
DEHR520DEHR530DEHR540DEHR555DEHR570
DEHR620DEHR630DEHR640DEHR655DEHR670
WideDEHW620DEHW630DEHW640DEHW655DEHW670
Regular
Cuff: 2, 3, 4, 5.5, 7mm
Prosthetic Components
e-Clean O-Ring Abutment Components
O-Ring Code No.
ORING
O-Ring Lab Analog Code No.
DOLA
O-Ring Retainer Code No.
DOR
O-Ring Abutment Platform Diameter Cuff Code No.Ø4.1
Ø5.1
2mm4mm
2mm4mm
DEORRA20DEORRA40
DEORWA20DEORWA40
Cuff: 2, 4mm
Temporary Abutment Platform Diameter Type Code No.Ø4.0Ø4.5Ø5.5Ø4.0Ø4.5Ø5.5Ø4.0Ø4.5Ø5.5Ø4.0Ø4.5Ø5.5
TitaniumHex
TitaniumN-Hex
PeekHex
PeekN-Hex
DETMHDETRHDETWHDETMNDETRNDETWN
DEPTMHDEPTRHDEPTWHDEPTMNDEPTRNDEPTWN
* Abutment+Abutment Screw Set Code : Abutment Code + S(ex: DETMHS)
Titanium
Hex
Hex
N-Hex
N-Hex
Plastic
Plastic UCLA Type Code No.
HexN-Hex
MiniDEPMHDEPMN
RegularDEPRHDEPRN
WideDEPWHDEPWNHex N-Hex
* Abutment+Abutment Screw Set Code : Abutment Code + S(ex: DEPMHS)
Gold UCLA Type Code No.
HexN-Hex
MiniDEGUMHDEGUMN
RegularDEGURHDEGURN
WideDEGUWHDEGUWNHex N-Hex
* Abutment+Abutment Screw Set Code : Abutment Code + S(ex: DEPMHS)
Angled Abutment Angle Cuff Height(H) Code No.
15˚
25˚
2mm4mm
2mm4mm
8mm
8mm
MiniDEAAM4215DEAAM4415
DEAAM4225DEAAM4425
DEAAR5215DEAAR5415
DEAAR5225DEAAR5425
DEAAR6215DEAAR6415
DEAAR6225DEAAR6425
WideDEAAW6215DEAAW6415
DEAAW6225DEAAW6425
Regular
* Abutment+Abutment Screw Set Code : Abutment Code + S(ex: DEAAM4215S)
15。 25。
Cuff: 2, 4mm
Dentis e-Clean System I Prosthetic Components I •08 ••09
e-Clean Tapered countersink
Twist Drill
Ø3.5
Ø0.9
Ø1.2
Ø4.1
Ø5.1
DTD3508DTD3510
DTD3512DTD3514
DRD09
DRD12S DRD12L
DTD4108DTD4110
DTD4112DTD4114
DTD5108DTD5110
DTD5112DTD5114
Ø3.5
Ø3.5
Ø4.1
Ø4.1
Ø3.5
DETCS35
Mini
DEFMSM
DMHD24
Ø4.1
DETCS41
Regular
DEFMSR
DMHD30
Ø5.1
DETCS51
Wide
DEFMSW
Code - DEK
05
06
07
08
01
02
04
03
09
10
1412
13
01 0503 04 06 07 08 09
02
12
13
10
11
14
Pilot Drill
Drill Extension
StraightTwist Drill
Mount Driverfor Machine
Short Mount
Hex Driver
Ø2.2
DTD2208DTD2210
DTD2212DTD2214
DTD2808DTD2810
DTD2812DTD2814
DSPD28
Ø2.8
Mount Driverfor Ratchet
DRHDS24 DRHDL24
DRHDS30 DRHDL30
Parallel Pin
DPPØ2.8DPD
DDE
Point Drill
DPDG
Torque RatchetProbe Depth Gauge
DTR
e - Clean tapered KIT
Ø3.5 Fixture D4 Bone Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø3.5 fixture D2-3 Bone Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø3.5 tapered drill → Ø3.5 countersink →Ø3.5 fixture D1 Bone Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø3.5 tapered drill → Ø3.5 countersink →Ø3.5 tap drill (option) → Ø3.5 fixture
Ø4.1 Fixture D4 Bone Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø3.5 tapered drill →Ø4.1 fixture D2-3 Bone Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø3.5 tapered drill →Ø4.1 tapered drill →Ø4.1 countersink →Ø4.1 fixture D1 Bone Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø3.5 tapered drill →Ø4.1 tapered drill →Ø4.1 countersink →Ø4.1 tap drill (option) → Ø4.1 fixture
Ø5.1 Fixture D4 Bone Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø3.5 tapered drill →Ø4.1 tapered drill →Ø5.1 fixture D2-3 Bone Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø3.5 tapered drill →Ø4.1 tapered drill → Ø5.1 tapered drill →Ø5.1 countersink →Ø5.1 fixture D1 Bone Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø3.5 tapered drill →Ø4.1 tapered drill → Ø5.1 tapered drill →Ø5.1 countersink →Ø5.1 tap drill (option) →Ø5.1 fixture
Drilling Sequence
Cleanlant Surgical Kit
11