Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
RESIDENTIAL ROOFING PROFILES
SUPER VICA 30” COVERAGE PANEL WITH A 3/4” RIB.
SUPER VIC’s greater strength permits spans of up to 24”. Minimum recommended pitch is 4:12.
A fully reversible sheet, with little or no waste, makes a perfect panel for roofs with valleys, cottage hips or dormers.
ULTRA-VICA 36” COVERAGE PANEL WITH A 3/4” RIB.
ULTRA-VIC is a very economical panel to use on straight gable roofs. Minimum recommended pitch is 4:12.
19 mm (3/4") 254 mm (10")
762 mm (30")
914mm (36")
19mm (3/4")
229mm (9")
VIC/ELITEA 16” COVERAGE PANEL WITH CONCEALED FASTENERS.
Our newest panel designed specifically for the residential market. Minimum recommended pitch is 4:12.
Available in our exclusive WeatherXTM Paint or an upgraded PVC paint system, complete with custom trims
designed to complement your home.
TRIMS & ACCESSORIESVICWEST offers a complete range of standard and custom trims and accessories.
3.8 mm (5/32")21.7 mm (7/8")
406 mm (16")
138 mm (5 7/16")
914 mm (36”)
229 mm (9”)19 mm (3/4”)
406 mm (16”)
21.7 mm (7/8”) 3.8 mm (5/32”) 138 mm (5 7/16”)
762 mm (30”)
19 mm (3/4”) 254 mm (10”)
3"
3"1/4"
1/2"
4"
4"1/4"
1/2"
3 3/8"1 1/4"
1 7/8"1/4"
1/2"
1"1/2"
1/8"3/4"
3 3/4"1/4"
3.75"
2.75"
1.5"
0.625"
2"
2"
3"
3"
1/2"
1"
1/2"
7"
4"
Bug Screen &Fibre Filling
2.75"
12.75"
3.5"
12.75" 4 3/4"
1"6"
4 3/4"
1"
6" 2"
2"
1/2"
RR-6 Ridge Cap
RR-8 Ridge Cap VMC Ridge Cap Ridge Cap F Gable Trim S-122 Eave Trim S-124 Gable Trim
Vented Ridge Single Line Ridge W-Valley
V-Valley
MASTER FLASHTM S-123 Gable TrimSidewall/Endwall
Flashing
1
RESIDENTIAL APPLICATION GUIDEfor SUPER VIC and ULTRA-VICThe following brochure is a step-by-step procedure for reroofing a residence. Great care must be taken to use the prop-er flashings and fittings to insure a perfect, long lasting, leak proof roof. Many inexperienced applicators try to cut cor-ners but the end result is a roof that fails! Please follow this guide and if you have any questions, contact yourAuthorized VICWEST Dealer for further information. VICWEST offers this installation as a guideline only andassumes no responsibility whatsoever regarding improper installation or improper use of its products.
19 mm (3/4") 254 mm (10")
762 mm (30")
RecommendedOverlapProcedure
SUPER VIC
ULTRA-VICRECOMMENDED PANEL FASTENING:
914mm (36")
19mm (3/4")
229mm (9")
AntisiphonOverlapProcedure
Large Tab (for use above profile)
WATERPROOFING AND SEALING
Metal Building TapeFoam Closures - Crosslinked Polyethylene
Small Tab (for use below profile)
Ridge End SealTape Sizes:
overlap: 1/16” x 1/4”endlap: 1/8” x 1/2”
In some conditions, Metal BuildingTape is suggested on overlapping ribs.Please consult your local VICWESTDistributor for detailed information.
2
STEP 1Draw a diagram of the roof or structure that you will becladding.To accurately estimate and order your new VICWESTproduct, all measurements must be precise and includedon your drawing. Include all valley lengths, cottage roofhip lengths, dormer sizes, rafter (measure from centre ofridge to outside of fascia board; do not deduct from thismeasurement) and ridge lengths, and the location andsizes of all chimneys, skylights and vent pipes. It is alsoimportant to know the approximate pitch of your roof, as itis imperative that flashings and ridge vents be made to suit.To determine the pitch of the roof, measure horizontallyacross the gable end and mark a distance of 12”. From thispoint, measure the vertical rise of the roof. This will giveyou the pitch; e.g., a 4” rise in 12” will be a 4:12 pitch. (Seediagram opposite.)Have yourVICWEST Dealer estimate your requirements.
STEP 2Once you have received your new VICWEST panels andaccessories, you are ready to proceed with the application.Cut off the overhanging old roofing flush with the fascia.Replace or repair any damaged or deteriorated fasciaboards. Check the structural integrity of the roof framingand repair any areas requiring attention.
STEP 3Using a minimum of 1” x 4” standard or better lumber,install nailers around pipes that protrude through theroof. Check the MASTER FLASHTM/RETROFIT MASTERFLASHTM section on page 12 for the location of the nailers.Then install nailers down the valleys and along ridges,hips and any other place where a flashing will berequired. In each case, check the flashing for the properlocation of the nailer. If Snow Guards will be required,check the detail on Pg. 6 and locate strapping accordingly.You may want to add the strapping for future requirements.STEP 4Strap the rest of the roof with a minimum of a 1” x 4” stan-dard or better lumber, placed at proper spans. Span infor-mation is available from your Authorized VICWESTDealer. It is recommended that strapping be screwed tothe roof as nails will pull out after a time. Be sure that allnailers are level - shim under nailers where necessary.
RESIDENTIAL APPLICATION GUIDEforSUPER VIC and ULTRA-VIC
4”12”
3
RESIDENTIAL APPLICATION GUIDEforSUPER VIC and ULTRA-VIC
Existing Eave Fascia Trim
VICWEST Roof Sheet
Optional SmallTab Foam
Eave CapRafter
Cut Sheathingflush with face
2"
3/4"
2"
Roofing Panel directly on TITANIUM-UDLUnderlayment or on Strapping over Shingles.(Consult VICWEST for safe spans.)
Existing GableFascia Trim
Gable Cap
Fascia Board
VICWEST Roof Sheet1 1/2" or 2"Nylon Head Screw
Cut Sheathingflush with face
2"
3/4"
2"Roofing Panel directly on TITANIUM-UDLUnderlayment or on Strapping lengthwiseup gable end over Shingles.
VICWESTPrepainted Steel Fascia
Fascia Board
VICWESTRoof Sheet Small Tab Foam
(Eave Closure)
1 1/2" or 2"Nylon Head Screw
Rafter
Standard Aluminum or Vinyl Vent-a-SoffitWall
4" to 6"
3/4"
Roofing Panel directly on TITANIUM-UDLUnderlayment or on Strapping over Shingles.(Consult VICWEST for safe spans.)
S-122 EAVE CAP DETAIL
VENT-A-SOFFIT DETAIL
S-123 GABLE CAP DETAIL
STEP 5Install the fascia cover flashings on eaves and gables.These are usually an S122 for the eaves and an S123 for thegables.
STEP 6Install the valley flashings using small galvanized nails tohold them in place. Screws will be applied later, securingthem permanently. Valley & Hip Sealer must be appliedon top of the wing of the valley flashing, between the roofpanels. This will ensure a water-tight joint.
Type "B" W-Valley(See VICWEST Trim Selection)
VICWESTRoof Sheet
Valley & Hip Sealer
New or existing Sheathing
4" to 6"
W-Valley and Roofing Panels directly on TITANIUM-UDLUnderlayment or on Strapping over Shingles.
W-VALLEY DETAIL
4
RESIDENTIAL APPLICATION GUIDEforSUPER VIC and ULTRA-VIC
Structural Fastener:Fasten panel to structural through crown of sheet.
Structural Fastener:Fasten panel to structural through flat of sheet.
Prevailing Wind Direction
Follow panel manufacturer's recommendations for proper fastener placement.
Apply sufficient torque to seat the washer.NOTE: Do not over-drive the fastener!
COMPRESSION
TOO LOOSECORRECT TOO TIGHT
Sealing materialslightly visible.
Sealing materialnot visible.
Metal Washerdeformed.
STEP 7Begin to apply the sheets. Be sure to start your sheetssquare, and in the case of ULTRA-VIC, lapping the shortlap over the full lap, as per specifications. It is recom-mended that you pre-drill your sheets where possible, bymeasuring the centres on your strapping and marking thesheets accordingly. This procedure will give you an aes-thetically pleasing look, as you will have straight rows ofscrews on the finished roof. Always pre-drill and cut thesheets from the back side, ensuring that all metals filingsare wiped from the sheet. Apply the sheets with nylonhead skirt flange screws. Great care must be taken that thewasher is compressed but not over-tightened, as shown inthe diagram opposite.Note: Lap joints should face away from prevailing winds.
STEP 8As you proceed across the roof, install flashings asrequired.
STEP 9Fasten ridge cap and/or vented ridge using nylon headscrews at each rib. The use of Large Tab Foam (over sheet)is highly recommended between the cap and the sheet.
NOTEVENTED RIDGE CAP, RAPID RIDGE OR VICWEST’SVENTED FOAM CLOSURE (shown on facing page)(FOR SUPER VIC, ULTRA-VIC and VIC/ELITE) IS AMUST ON ANY ROOF APPLICATION.THE BUILDING CODE REQUIRES PROPER VENTI-LATION AND VICWEST STRONGLY SUPPORTSTHIS, AS POOR VENTILATION IS THE MAJORCAUSE OF CONDENSATION IN AN ATTIC! VMC Ridge Cap
VICWESTRoof Sheet
Large TabFoam Closure
2 1/2" Woodscrew
Vent Mesh
ROLL VENT
1 3/4"
3 3/8"6 1/2"
1 1/4" 1 7/8"4"
Roofing Panels directly onTITANIUM-UDL Underlaymentor on Strapping over Shingles.
RIDGE CAP Finished End View
RAPID RIDGE Installation
Prevailing WindDirection
5
RESIDENTIAL APPLICATION GUIDEforSUPER VIC and ULTRA-VIC
FOAM CLOSURE
ROOF CLADDING
VENTROOF FLANGE
VICWEST MODEL 120010ft. ROOFLINERIDGE VENT
VENTENDPANEL TAB
Drainage Holes
VENT CONNECTOR FLANGE(for running vents continuously- replaces VENT END FLANGE)
SINGLE LINERIDGE CAP
VENTEND FLANGE
REAR VIEW
TOP VIEW
FRONT VIEW END VIEW
RAIN GUARD
RAIN, SNOW & BUG SCREEN CLAMP ASSEMBLIES
VENTED FOAM CLOSUREFEATURES & BENEFITSVICWEST Vented Foam Closure is designed to fit under-neath your Ridge Cap, giving a clean unobtrusive appear-ance. It provides 4.5 sq. ins. of free air intake per linealfoot of closure or 9 sq. ins. per lineal foot of ridge.VICWEST Vented Ridge consists of 3 basic components.The Front Vent has bug screen and weep holes, the centralcomponent is a Rain Baffle and the Back Vent has a glueline for ease of installation.N.B.: This Closure can be combined with our ResidentialEndwall RE-8 to create a Ventilated Endwall.
INSTALLATION1) Keep your roof sheet back 2” from the ridge line.2) Peel paper from glue line on Back Vent.3) Place Closure Vent on panel with weep holes to the
front.
VICWEST VENTED RIDGE
VENTED FOAM CLOSURE
INSTALLATION INSTRUCTIONS1. Apply roof cladding leaving the required opening for
the VICWEST 10’ Roofline Ridge Vent (2 3/4” wide x120” long).
2. Install the ridge cover over the roof cladding up to theedge of the roof opening.
3. Each vent carton contains 2 end flanges and 1 connec-tor flange.– End flanges are used when vents are installed indi-vidually. Install end flanges on the inside of the ventend panel as shown.– Connector flanges are used between vents when run-ning vents continuously (do not use end flanges here!).Butt two vents together with the connector flangeunderneath at the joint. Both vent end panels fitbetween the two tabs on the connector flange.
4. Install the vent over the opening using the properfoam closure to suit the roof cladding profile. Makesure the foam closure does not block drainage holes inthe roof flange.
VICWEST 10’ RIDGE VENT
5. Vent should be fastened on the ribs of roof claddingand a generous bead of caulking must be appliedbetween the ridge cover and the vent end flanges orconnector flanges.
6. IT IS IMPERATIVE THAT YOU ORDER THECORRECT VENTED RIDGE FOR YOUR PROJECT!THE PITCH OF THE ROOF MUST BE SPECIFIEDIN ORDER THAT A CORRECT UNIT MAY BEMANUFACTURED.
4) Install Ridge Cap. (Due to the size of the vented clo-sure and the requirement to leave a vent space at theridge line, it will be necessary to use a larger RidgeCap than normal. Style RR-8 Ridge is recommended.)
6
If re-roofing over shingles, strap up each side of the hip,checking the flashing (hip cap) for proper placement ofthe nailer.Cut the angle required on the steel panel and install on thehip. Apply Valley & Hip Sealer down both sides of the hipand screw the hip cap on, using a nylon head screw ateach rib as shown on the drawing.
See Pg. 7 for additional trim options.
COTTAGE HIP DETAIL RR Ridge Cap(6" x 6" or 8" x 8")
VICWESTRoof Sheet
Valley & Hip Sealer
1 1/2" or 2"Nylon Head Screws
New or existing SheathingRoofing Panel directly on TITANIUM-UDLUnderlayment or on Strapping over Shingles
RESIDENTIAL APPLICATION GUIDEforSUPER VIC and ULTRA-VIC
BRICK CHIMNEYSIt is recommended that, when a brick chimney is presentin a re-roof application with VICWEST steel, a saddle bebuilt on the back of the chimney to deflect snow andwater around the chimney.
Chimney Flashing
Ridge Cap
Valley(only one shown)
STEP 10 OPTIONS
SNOW RESTRAINTDrifts of snow and ice accumulating on top of homes maysuddenly cascade down and off roofs. This can tear off gut-ters and cause damage to people or objects below.The potential for snow pile-up on a roof can vary greatly,depending on building location and geometry. If signifi-cant loading is expected on a restraining system, an engi-neered system appropriately anchored to the buildingstructure should be investigated. If minor loading is envi-sioned, one of the following options may be appropriate.1. SNOWGUARDSSnow guards may hold back or retard the movement ofsnow or ice.2. POLAR BLOXThis polycarbonate product is intended to solve the prob-lem of ice and snow movement. This item must be installedin accordance with the manufacturer’s directions:1) Apply a transparent silicone sealant to the base (non-acetic acid type on Galvalume or Galvanized roofs).
2) Using 2 self-tapping #14 screwsw/neoprene washers, screw throughthe Polar Blox and roofing materialinto the purlin or structural support.
3 1/2"
1"1 1/2"
2"
SNOW GUARD Colour Cap
R
18 ga. Galv. Inner
STEEL PANEL
1" x 4" NAILERS
PLYWOOD
Sealant required between top of steel panel and base of Snow Guard
4 1/4"
SNOW GUARD
POLAR BLOX
a) Slope 0 to 2/12: 1 staggered row up to 50’ of roof length.2’ max. on centre horizontally.
b) Slope 3/12 to 6/12: 1 staggered row every 25’ of roof length.2’ max. on centre horizontally.
c) Slope over 6/12: 1 straight row every 12’ of roof length.1’ max. on centre horizontally.
a)
b) c)
7
RESIDENTIAL APPLICATION GUIDEforSUPER VIC and ULTRA-VIC
REMEMBER, ON ALL APPLICATIONS1. Always use screws, not nails.2. Use a proper screw gun, not a drill with a socket.3. Use the proper flashing around the vents.4. Flash all exposed edges with standard or custom flash-
ing available from VICWEST.5. All cutting of steel should be done on reverse side of
sheet. Ensure that all metal filings are wiped clean fromsheet.
6. Recommended cutting tools: circular saw with metalcutting blade, electrical nibblers or shears, tin snips foraround chimney.
NEW CONSTRUCTIONOn new roofs,VICWEST recommends sheathing coveredwith TITANIUM-UDL Metal Roofing Underlayment, thesteel then being laid directly on the Underlayment.
Before proceeding with such an installation, always con-sult your local building inspector. VICWEST offers thisinstallation as a guideline only and assumes no responsi-bility whatsoever regarding improper installation orimproper use of its products.
OTHER TRIM OPTIONS:
6" 1"120°
4 3/4"Specify Pitch
New or Existing Counter-Flashing
Tapcon or Lead Anchor
VICWESTRoof Sheet
1 1/2" or 2"Nylon Head Screws
New or existingSheathing
Chimney Flashing #1
Valley & Hip Sealer
Chimney
Roofing Panel directly on TITANIUM-UDLUnderlayment or on Strapping over Shingles.
Specify Pitch
5 1/2" 1"
3 3/4"
3/4"
1/2"
Chimney Flashing #2
1/2"
3 3/4"
VICWESTRoof Sheet
1 1/2" or 2"Nylon Head Screws
Caulking
Measure Kerf Cutplacementfrom this point
Kerf Cut
Chimney
Tapcon or Lead Anchor
Large Tab Foam Closure
New or existing Sheathing
Roofing Panel directly on TITANIUM-UDLUnderlayment or on Strapping over Shingles.
Specify Pitch
5 1/2"1"
5"
1/2"
Chimney Flashing #3
VICWEST Roof Sheet
Large Tab Foam Closure
1 1/2" or 2" Nylon Head Screws
Tapcon or Lead Anchor to chimney
Caulking
Chimney
New or existing Sheathing
Roofing Panel directly on TITANIUM-UDLUnderlayment or on Strapping over Shingles.
Cut existing Chimney Flashing. Slide Nailer of ChimneyFlashing #1 up underneath new or existing Counter-Flashing. Note that the Wall Nailer may have to betrimmed to fit. Fasten to Chimney with Tapcon or LeadAnchor fasteners.
This installation involves cutting a 1” deep slot in thebrick with a Concrete Diamond Blade.Install Chimney Flashing #2 as shown in diagram. Fastento Chimney with Tapcon or Lead Anchor fasteners.
Install as shown. Fasten to Chimney with Tapcon or LeadAnchor fasteners.
ChimneyFlashing #1
ChimneyFlashing #2
ChimneyFlashing #3
2 3/4"
2"
Upper VICWESTRoof Sheet
1 1/2" or 2"Nylon Head Screws
New or existing Sheathing
Roofing Panel directly on TITANIUM-UDLUnderlayment or on Strapping over Shingles
Install LowerVICWEST Roof Sheet first
Small Tab Super VicFoam Closure
Super Vic Reverse Hip
NOTE: Also applies to Plain Hip Cap Reversed or C-121 Flashing
Notched end
Large Tab Super VicFoam Closure
Transition Trim Installation
8
3.8 mm (5/32")21.7 mm (7/8")
406 mm (16")
138 mm (5 7/16")
V
RecommendedOverlapProcedure
Snap Down
Fastener Flange
RESIDENTIAL APPLICATION GUIDEfor theVIC/ELITE CONCEALED FASTENER ROOFING SYSTEM
VIC/ELITE
ACCEPTABLE CONSTRUCTION PROCEDURESSolid decking (min. 1/2” plywood or 7/16” OSB) covered withan approved fully adhered Metal Roofing Underlayment.Steel roofing installed flat on Underlayment. This proce-dure is also applicable to a re-roof after existing shinglesare removed and underlayment installed.
INSTRUCTIONS - STEP 1Draw a diagram of the roof or structure that you will becladding.To accurately estimate and order your new VICWESTproduct, all measurements must be precise and includedon your drawing. Include all valley lengths, cottage roofhip lengths, dormer sizes, rafter (measure from centre ofridge to outside of fascia board; do not deduct from thismeasurement) and ridge lengths, and the location andsizes of all chimneys, skylights and vent pipes. It is alsoimportant to know the approximate pitch of your roof, as itis imperative that flashings and ridge vents be made to suit.To determine the pitch of the roof, measure horizontallyacross the gable end and mark a distance of 12”. From thispoint, measure the vertical rise of the roof. This will giveyou the pitch; e.g., a 4” rise in 12” will be a 4:12 pitch (perdiagram above). Have your VICWEST Dealer estimateyour requirements.
STEP 2Once you have received your new VICWEST panels andaccessories, you are ready to proceed with the application.Cut off the overhanging old roofing flush with the fascia.Replace or repair any damaged or deteriorated fasciaboards. Check the structural integrity of the roof framingand repair any areas requiring attention.
4”12”
S-124 GABLEFLASHING
Fasteners w/Washers attached
Silicone
Roof Sheet S-124
To ensure a proper seal on Roof side of S-124:After screwing down, remove screws and trim.Add a small dab of silicone sealant to sealscrews at roof surface and refasten into same holes.
3"
3"
1/2"
1"
1/2"
STEP 3Install the fascia cover flashings on eaves and gables.These are usually an S122 for the eaves and an S124 for thegables as in the drawing shown here, installed after thefirst sheet is applied on the gable end.
9
RESIDENTIAL APPLICATION GUIDEfor theVIC/ELITE CONCEALED FASTENER ROOFING SYSTEM
STEP 5
Begin to apply sheets. Starting from left to right, depend-ing on the prevailing wind direction, fasten the first sheetat the gable end with a #12 truss head screw on 16” cen-tres up the entire length of the sheet. On the flange side ofthe sheet, fasten same as gable.2nd Sheet: Starting at the top or bottom, place sheet lapover rib to cover screwed down flange. Lock panel inplace by hitting rib with a rubber mallet, traversing up ordown the sheet again to make a tight lock.CAUTION: Do not start at both ends and snap togethertowards the middle!3rd Sheet: Same as 2nd, and so on.Check regularly to ensure that the sheets are square andadjust accordingly if out of alignment.STEP 6At the bottom of the sheets, install three 1” nylon headscrews in the flat area of the sheet as per the drawing onthe right. At rib overlaps, install a 2” nylon head screw inthe top of the rib as an aid against the sheets pulling apart.STEP 7As you proceed across the roof, install flashings asrequired.STEP 8Fasten ridge cap and/or vented ridge using nylon headscrews at each rib. The use of Large Tab Foam (over sheet)is highly recommended between the cap and the sheet.
Prevailing WindDirection
9 1/4" 9 1/4"1" 1"
2 PIECE VALLEYFLASHING
STEP 4Install the valley flashings using small galvanized nails tohold them in place. Screws will be applied later, securingthem permanently. Valley & Hip Sealer must be appliedon top of the wing of the valley flashing, between the roofpanels. This will ensure a water-tight joint.
3"
Fasteners with washers attached
10
RESIDENTIAL APPLICATION GUIDEfor theVIC/ELITE CONCEALED FASTENER ROOFING SYSTEM
FOAM CLOSURE
ROOF CLADDING
VENTROOFFLANGE
VICWEST MODEL 120010ft. ROOFLINERIDGE VENT
VENTENDPANEL TAB
Drainage Holes
VENT CONNECTOR FLANGE(for running vents continuously- replaces VENT END FLANGE)
SINGLE LINERIDGE CAP
VENTEND FLANGE
VICWEST VENTED RIDGE
UPLIFT COMMENTARYWind uplift to be resisted by the roof panels depends on anumber of factors, including building location and height,roof shape and construction, etc.Uplift will also often be higher near the corners and/orthe perimeter of the roof area. In many cases, installingVic/Elite as described in the application guide is satisfac-tory.If wind uplift is expected to be higher than normal, fastenerspacing closer than 16” is recommended.Under some extreme conditions, it may also be necessary toprovide additional stitch fasteners at the ribs to prevent thedisengagement of the side lap.
NOTE
VENTED RIDGE CAP, RAPID RIDGE OR VICWEST’SVENTED FOAM CLOSURE (see pgs. 4 & 5) (FORSUPER VIC, ULTRA-VIC and VIC/ELITE) IS A MUSTON ANY ROOF APPLICATION.THE BUILDING CODE REQUIRES PROPER VENTI-LATION AND VICWEST STRONGLY SUPPORTSTHIS, AS POOR VENTILATION IS THE MAJORCAUSE OF CONDENSATION IN AN ATTIC!
NOTES
11
If re-roofing over shingles, strap up each side of the hip,checking the flashing (hip cap) for proper placement ofthe nailer.Cut the angle required on the steel panel and install on thehip. Apply Valley & Hip Sealer down both sides of the hipand screw the hip cap on, using a nylon head screw ateach rib as shown on the drawing.
COTTAGE HIP DETAIL
COTTAGE HIP DETAILRR Ridge Cap(6" x 6" or 8" x 8")
VICWESTRoof Sheet
Valley & Hip Sealer
1 1/2" or 2"Nylon Head Screws
New or existing SheathingRoofing Panel directly onMetal Roofing Underlayment
RESIDENTIAL APPLICATION GUIDEfor theVIC/ELITE CONCEALED FASTENER ROOFING SYSTEM
ENDLAPPING VIC/ELITE(if required)
(Use a 6” to 8” endlap)1) Apply complete lower course of roofing panels2) Stop end the upper end of the lower course approxi-
mately 15° up. This creates an anti-siphon area.3) Use a pinching tool to compress the ribs the same
length as the overlap. The compressed rib will nowaccept the upper course of roofing panels.
4) Apply two rows of 1/8” Butyl caulk across the lap.Locate the first bead above the bottom edge of theupper course position and the second bead 1” abovethe lower.
5) Apply the upper course of roofing panels, overlap-ping the bottom course by 6” - 8”.
6) Install a fastener (with washer attached) in each flatarea between the two rows of Butyl caulk. Also applya stitching screw on top of each rib.
Lap6" - 8"
Use Pinching Toolto compress rib thelength of the lap.
1/8" Butyl Caulking
Fasteners w/WasherAttached
Stitching Screws
Stopendup 15°
ENDLAP DETAIL
REMEMBER, ON ALL APPLICATIONS1. Always use screws, not nails.2. Use the proper flashings and closures.3. Always ensure that you have adequate ventilation for your roof to perform well.4. All cutting of steel should be done on reverse side of sheet. Ensure that all metal filings are wiped clean from sheet.
Recommended cutting tools: electrical nibblers, shears or tin snips.NOTE: A circular saw with a metal cutting blade is NOT recommended for this panel, as the heat from the blade can
blister the PVC paint used for this product.
MASTER FLASHTM INSTALLATION
1. TRIM 2. SLIDE 3. SEAL 4. FORM 5. FASTEN
12
Cut opening 20% smallerthan pipe diameter.
Slip MASTER FLASHTM
over pipe.Apply urethane/siliconesealant betweenMASTER FLASHTM androofing.
Bend aluminum base tofit irregularities. Uselarge slot screwdriver topress into tight angles.
Complete the seal usingcommon weather-resistant fasteners.
SELECTION CHARTMASTER FLASHTM Pipe Base Opening
Number Size Dimension Diameter1 1⁄4” - 2” 41⁄2” Closed2 11⁄4” - 3” 6” 7⁄8”3 1⁄4” - 4” 8” Closed4 3” - 6” 10” 21⁄2”5 4” - 7” 11” 31⁄2”6 5” - 9” 12” 4”7 6” - 11” 14” 5”8 7” - 13” 17” 6”
RETROFIT MASTER FLASHTM
For use with hydro masts and vent pipes.Cut to size, place bead of silicone around metal base formbase to ribs or profile and then fasten with skirt flangescrews.
DESIGNATED PIPE SIZE
1/2" to 4" EPDMSILICONE
EPDMSILICONE
EPDMSILICONE
101 RF102 RF
201 RF202 RF
301 RF302 RF
4" to 9 1/4"
9 1/4" to 16 1/4"
COMPOUND CODE FLASHING DETAILSA - TOP OPENING DIAMETER
B - CUT TO SUIT PIPE SIZE
C - BASE DIMENSIONS
1/2"
1/2" to 4"
8 3/16"
4"
4" to 9 1/4"
14 1/4"
9 1/4"
9 1/4" to 16 1/4"
21 1/2"
A - TOP OPENING DIAMETER
B - CUT TO SUIT PIPE SIZE
C - BASE DIMENSIONS
A - TOP OPENING DIAMETER
B - CUT TO SUIT PIPE SIZE
C - BASE DIMENSIONS
A
B
CA
B
CA
B
C
VICWEST CUSTOM COLOURS
VICWEST roofing is available in a wide range of colours. The following are our most popular.For colour availability, please contact your local authorized VICWEST dealer.
SUPER VIC/ULTRA-VIC PROFILES
Colour matching variation is possible from one production lot toanother. We recommend that complete orders of each colour for aproject be placed at one time!
The colours shown below are representative only, therefore we alsorecommend that you check your VICWEST distributor’s samplesbefore making a colour selection.
VIC/ELITE CONCEALED FASTENER SYSTEM
Hunter GreenVW 1594
Tile RedVW 1558
BlackVW 1517
Dark BrownVW 1518
CharcoalVW 1504
Galvalume
4 mil BARRIER SERIES
WeatherXTM
Dark GreenVW 16073
Tile RedVW 16066
BlackVW 16068
Cocoa BrownVW 16077
CharcoalVW 16072
Bright RedVW 16080
Royal BlueVW 16081
Regent GrayVW 16082
Dark GreenVW 16073
Cocoa BrownVW 16077
Bright RedVW 16080
GreenVW 16078
BlackVW 16068
CharcoalVW 16072
Regent GrayVW 16082
GreenVW 16078
Bone WhiteVW 16069
White WhiteVW 16076
TanVW 16074
Slate BlueVW 16067
THERE IS NOEQUIVALENT
!
ONLY VICWEST CAN GIVE YOU THE
BEST ROOFYOU WILL E
VER HAVE!
QUALITY AND PERFORMANCE SPECIFICATIONforWeatherX™ (SMP) PREFINISHED SHEET STEEL
VICWEST is engaged in continuing research to improve our products, therefore wereserve the right to modify or change this information without prior notice.WeatherXTM is a trademark of the Valspar Corporation.
1.0 SCOPEThe following specifications shall apply to hot dipped metallic coatedsheet steel prefinished with colours of proven durability and suitable forexterior exposure as delivered from the coil coater. The WeatherX™ paintsystem has been designed for both vertical applications and non-verticalapplications whose surfaces range from 5° up to 60° to the horizontal.It is not recommended for severely aggressive exposure.
2.0 BASE METALThe base metal furnished before painting shall conform to one of thefollowing specifications:(a) Continuous hot dipped zinc coated (galvanized) sheet steel
conforming to the requirements of ASTM A653 or ASTM A653Mas applicable.
(b) Continuous hot dipped aluminum zinc alloy coated sheet steelconforming to the requirements of ASTM A792 or ASTM A792Mas applicable.
3.0 PAINT QUALIFICATION TESTS3.1 Film Thickness(a) The exposed surface shall have a dry film thickness of
25 m ± 5 m (1.0 ± 0.2 mils).(b) The unexposed or reverse side shall have a dry film thickness, which
will vary in accordance with the customer’s requirements.(c) Test Method: ASTM D1005 or NCCA 4.2.1.
3.2 Film CureThe baked film shall withstand one hundred and fifty (150) doubleMEK rubs in accordance with ASTM D5402 or NCCA 4.2.11.
3.3 Film Hardness (Pencil Method)(a) Paint film hardness is measured by means of a set of calibrated draw-
ing leads (Berol Turquoise T2375 or equivalent). The Pencil Hardnessis specified as the first pencil grade that will not rupture the paint filmwhen sharpened to a round flat point and applied at a 45° to thepaint surface. A minimum hardness of F shall be achieved.
(b) Test Method: ASTM D3363 or NCCA 4.2.5.
3.4 Formability/Adhesion Test(a) When using a representative sample at 20°C ± 1.5°C (70°F ± 5°F)
using #610 Scotch brand cellophane tape, the paint system will showno loss of adhesion when subjected to a 3T 180° bend test.
(b) Test Method: ASTM D4145 or NCCA 4.2.8.
3.5 Gloss(a) The specular gloss shall be ± 5 gloss units of the agreed-upon
specified target when measured with a Gardner 60° Glossmeter.(b) Test Method: ASTM D523 or NCCA 6.1.6.
4.0 ACCELERATED CORROSION4.1 Humidity Resistance(a) The humidity resistance test shall be conducted at 100% relative
humidity at a temperature of 38°C (100°F).(b) After 1000 hours of exposure, the surface will show no blisters
(on HDG and Galvalume substrates).(c) Test Method: ASTM D2247 or NCCA 5.4.4.
5.0 EXTERIOR EXPOSURE (WEATHERING)When installed in Canada or the USA, each WeatherX™ colour ofproven durability shall successfully meet the following weatheringstandards:
5.1 Film IntegrityDuring the first 40 years of exterior exposure (and in the absence ofaggressive fumes and/or other chemicals not normally encountered inthe atmosphere), the paint film shall have no evidence of cracking,chipping, peeling, crazing, spotting or loss of adhesion apparent onnormal outdoor visual observations.
5.2 ChalkingDuring the first 30 years of exterior exposure, the chalking in verticalapplications shall not exceed a No. 8 rating and in non-verticalapplications shall not exceed No. 6 per ASTM D4214, method A,or NCAA 5.5.2.
5.3 Colour ChangeDuring the first 30 years of exterior exposure, the colour change invertical applications shall not exceed five (5) colour units, and innon-vertical applications the colour change shall not exceed eight (8)colour units per ASTM D2244 or NCCA 6.1.5. Colour measurementsare to be made only on clean surfaces after removing surface depositsand chalk per ASTM D3964. Colour change is measured on anyaccepted colorimeter designed to produce reflectance readings in theTristimulus Filter System of X, Y and Z based on the CIE values ofilluminant C and measured in Hunter L, a and b units.
For more information on VICWEST products, please contact your localauthorized VICWEST dealer.
™
1.5M ©VICWEST/Sept. 2009