1
A R C H I T E C T 215 Juan Luna Street Binondo, Manila 23 Flr Unit 03 World Trade Exchange Building CA ARCHITECT ARCHITECT ENGINEERING CONSULTANT DATE ISSUED PRC NO. PTR NO. Mobile No. 0917-8282013 Tel. No. 242-0933 Section 25 (4) REPUBLIC ACT 545 TIN NO. PLACE PRESIDENTIAL DECREE NO. 49 OWNER LOCATION APPROVAL DRAWN DATE CHECKED PROJECT REVISIONS: DESIGNED SHEET CONTENTS: SHEET NO. ANDREW CHENG 08071979 8744552 06-09-10 187-299-017 MANILA J.J.DUFF ALL WORKS SHALL COMPLY WITH THE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, WITH THE RULES AND REGULATIONS OF THE NATIONAL AND LOCAL AUTHORITIES CONCERNED WITH ENFORCEMENT OF THE ELECTRICAL LAWS AND ORDINANCES AND WITH THE RULES AND REGULATION OF THE UTILITY COMPANIES CONCERNED. 1. SERVICE SHALL BE 230 VOLTS, 1-PHASE, 3-WIRES. 2. SERVICE ENTRANCE SHALL BE IN RIGID STEEL CONDUIT (RSC) "MATSUSHITA" OR APPROVED EQUAL. 5$&(:$<6 6+$// 127 %( 60$//(5 7+$1 00 56& 2876,'( ',$0(7(5 75$'( 6,=( $1' :,5(6 6+$// 127 %( 60$//(5 THAN 3.5mm INSULATED FOR 600 VOLTS. 3. BRANCH CIRCUIT WIRING SHALL BE DONE IN SCHEDULE RIGID STEEL CONDUIT WHERE TYPE THHN WIRES AREA USED. ALL BRANCH CIRCUIT SHALL BE PROVIDED WITH GREEN INSULATED GROUND WIRES. 5. DUPLEX RECEPTACLE OUTLETS SHALL BE RATED 10A, 250 VOLTS, GROUNDING TYPE "NATIONAL". SPECIAL PURPOSE OUTLETS SHALL BE OF TYPE AND RATING SUITABLE FOR THE EQUIPMENT SERVED. 6. LIGHT CONTROL SWITCHES SHALL BE RATED 15A, 300 VOLTS, "PANASONIC" 7. OUTLET BOXES SHALL BE GAUGE#1.55mm(MINIMUM) PRESSED-STEEL, GALVANIZED, 55mm DEEP. 8. ALL MATERIALS TO BE USED SHALL BE NEW AND OF APPROVED TYPE FOR THE LOCALTION AND PURPOSED 9. MOUNTING HEIGHTS SHALL BE AS FOLLOWS: a. LIGHTING CONTROL SWITCHES & PUSH BUTTON b. WALL RECEPTACLE, TEL. AND TV ANTENNA OUTLETS. c. RANGE OUTLET d. SPECIAL PURPOSE OUTLET e. PANELBOARDS AND CABINET = 1.37m ABOVE FLOOR AT CENTER 0.30 ABOVE FLOOR AT CENTER 0.60 ABOVE FLOOR AT CENTER AS REQUIRED BY EQUIPMENTER SERVED, VERIFY = = = = 1.37M ABOVE FLOOR AT CENTER UNLESS OTHERWISE REQUIRED BY FIELD CONDITIONS ALL MOUNTING HEIGHTS SHALL BE SUBJECT TO PRIOR APPROVAL BY THE ARCHITECT. LOCATION MAP LP-1 ELP-1 a a a a b b b f c c c g d c f c f c f g g d d d a l e e e e e e e g h h h h h h h j k j k f m n m n m n n m m n m n m n m n m ELP MTS LP S S ABOVE CEILING S S LP-3 LP-7 LP-6 LP-4 LP-5 LP MTS ELP NNà5))/ NNà 5))/ */ NNȾ 34$ MTS; 2-20AT, 50AF,2PCB,240V, 10 KAIC, B.O. WITH MECHANICAL INTERLOCK IN NEMA-I ENCLOSURE AT ELECTRICAL ROOM\ NORMAL POWER (VERIFY) EXACT LOCATION) EMERGENCY POWER AT ELECTRICAL M M NNà5))/ NNà 5))/ */ NNȾ 34$ (50/44.00A) 1000 505 4.35 2.19 PPð7++1 PPð7++1 ,1 PP56& PPð7++1 PPð7++1 IT = 47.36 AMPERES USE: 2-8.0mm 2 THHN, 1-5.5mm 2 7++1 ,1 PP 56& 47.36 AMPS) MAIN: 60AT, 60AF,2PCB,240V,10KAIC, B.O. 5 1000 4.35 1000 4.35 1000 4.35 1000 4.35 1000 4.35 1000 4.35 PPð7++1 PPð7++1 LEGEND CT DUPLEX CONVENIENCE OUTLET COUNTERTOP OUTLET ELECTRICAL PANELBOARD ONE - SINGLE POLE SWITCH IN A GANG TWO - SINGLE POLE SWITCH IN A GANG THREE - SINGLE POLE SWITCH IN A GANG 11 WATTS PINLIGHT CIRCUIT HOMERUN TO PANEL GENERAL NOTES SINGLE LINE DIAGRAM SCALE N.T.S. LIGHTING LAYOUT SCALE 1:50 POWER LAYOUT SCALE 1:50 PPð7++1 PPð7++1 ,1 PP56& IT = 2.19AMPERES USE: 2-5.5mm 2 THHN, 1-2.0mm 2 7++1 ,1 PP 56& $036 MAIN: 20AT, 50AF,2PCB,240V,10KAIC, B.O. DO LOAD COMPUTATION SCALE N.T.S. 20-WATT T5 ELECTRONIC LAMP 25 WATTS PILOT LIGHT 11 WATTS EMERGENCY PINLIGHT 20-WATT T5 EMERGENCY ELECTRONIC LAMP SHEET CONTENTS: SHEET NO. VICINITY MAP LOCATION MAP GENERAL NOTES LEGEND E 1 SINGLE LINE DIAGRAM LOAD COMPUTATION ELECTRICAL LAYOUTS UNIT 222 SECOND FLR.SM CITY GEN. SAN., GENERAL SANTOS, PHILIPPINES

E1.pdf

Embed Size (px)

Citation preview

Page 1: E1.pdf

A R C H I T E C T

215 Juan Luna Street Binondo, Manila

23 Flr Unit 03 World Trade Exchange Building

CA ARCHITECT

ARCHITECT ENGINEERING CONSULTANT

DATE ISSUED

PRC NO.

PTR NO.

Mobile No. 0917-8282013

Tel. No. 242-0933

Section 25 (4)

REPUBLIC ACT 545

TIN NO.

PLACE

PRESIDENTIAL DECREE NO. 49

OWNER

LOCATION

APPROVAL

DRAWN

DATE

CHECKED

PROJECT

REVISIONS:

DESIGNED SHEET CONTENTS:

SHEET NO.

ANDREW CHENG

08071979

8744552

06-09-10

187-299-017

MANILA

J.J.DUFF

ALL WORKS SHALL COMPLY WITH THE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, WITH THE RULES

AND REGULATIONS OF THE NATIONAL AND LOCAL AUTHORITIES CONCERNED WITH ENFORCEMENT OF THE ELECTRICAL LAWS AND

ORDINANCES AND WITH THE RULES AND REGULATION OF THE UTILITY COMPANIES CONCERNED.

1. SERVICE SHALL BE 230 VOLTS, 1-PHASE, 3-WIRES.

2. SERVICE ENTRANCE SHALL BE IN RIGID STEEL CONDUIT (RSC) "MATSUSHITA" OR APPROVED EQUAL.

4. RACEWAYS SHALL NOT BE SMALLER THAN 15MMØ RSC (OUTSIDE DIAMETER). TRADE SIZE AND WIRES SHALL NOT BE SMALLER

THAN 3.5mm INSULATED FOR 600 VOLTS.

3. BRANCH CIRCUIT WIRING SHALL BE DONE IN SCHEDULE RIGID STEEL CONDUIT WHERE TYPE THHN WIRES AREA

USED. ALL BRANCH CIRCUIT SHALL BE PROVIDED WITH GREEN INSULATED GROUND WIRES.

5. DUPLEX RECEPTACLE OUTLETS SHALL BE RATED 10A, 250 VOLTS, GROUNDING TYPE "NATIONAL". SPECIAL PURPOSE OUTLETS

SHALL BE OF TYPE AND RATING SUITABLE FOR THE EQUIPMENT SERVED.

6. LIGHT CONTROL SWITCHES SHALL BE RATED 15A, 300 VOLTS, "PANASONIC"

7. OUTLET BOXES SHALL BE GAUGE#1.55mm(MINIMUM) PRESSED-STEEL, GALVANIZED, 55mm DEEP.

8. ALL MATERIALS TO BE USED SHALL BE NEW AND OF APPROVED TYPE FOR THE LOCALTION AND PURPOSED

9. MOUNTING HEIGHTS SHALL BE AS FOLLOWS:

a. LIGHTING CONTROL SWITCHES & PUSH BUTTON

b. WALL RECEPTACLE, TEL. AND TV ANTENNA OUTLETS.

c. RANGE OUTLET

d. SPECIAL PURPOSE OUTLET

e. PANELBOARDS AND CABINET

=1.37m ABOVE FLOOR AT CENTER

0.30 ABOVE FLOOR AT CENTER

0.60 ABOVE FLOOR AT CENTER

AS REQUIRED BY EQUIPMENTER SERVED, VERIFY

=

=

=

=

1.37M ABOVE FLOOR AT CENTER UNLESS OTHERWISE

REQUIRED BY FIELD CONDITIONS

ALL MOUNTING HEIGHTS SHALL BE SUBJECT TO PRIOR APPROVAL BY THE ARCHITECT.

LOCATION MAP

LP-1

ELP-1

aaa abbb

f

c

c

c

g

dc

f

c

f

c

f gg

ddd

a

l

e e e e e e e

g

hhhhhhh

j

k

j

k

f

mnmnm

n n mm

nm

n m

nm

n m

ELPMTSLP

S

S

ABOVECEILING

S

S

LP-3

LP-7 LP-6

LP-4

LP-5

LP

MTS

ELP

2#5.5mm²THHN1#2.0mm² THHNIN 15mm∅ RSC

MTS; 2-20AT, 50AF,2PCB,240V,10 KAIC, B.O. WITHMECHANICAL INTERLOCK INNEMA-I ENCLOSURE

AT ELECTRICAL ROOM\NORMAL POWER (VERIFY)EXACT LOCATION)

EMERGENCY POWERAT ELECTRICAL

MM

2#8.0mm²THHN1#5.5mm² THHNIN 20mm∅ RSC(50/44.00A)

1000

505

4.35

2.19

2-3.5mm²THHN,

1-2.0mm²THHN,

IN 15mmØRSC.

2-5.5mm²THHN,

1-2.0mm²THHN,

I

T

= 47.36 AMPERES

USE: 2-8.0mm

2

THHN, 1-5.5mm

2

THHN IN 20mmØ RSC. (60/47.36 AMPS)

MAIN: 60AT, 60AF,2PCB,240V,10KAIC, B.O.

5

1000 4.35

1000 4.35

1000 4.35

1000 4.35

1000 4.35

1000 4.35

2-5.5mm²THHN,

1-2.0mm²THHN,

LEGEND

CT

DUPLEX CONVENIENCE OUTLET

COUNTERTOP OUTLET

ELECTRICAL PANELBOARD

ONE - SINGLE POLE SWITCH IN A GANG

TWO - SINGLE POLE SWITCH IN A GANG

THREE - SINGLE POLE SWITCH IN A GANG

11 WATTS PINLIGHT

CIRCUIT HOMERUN TO PANEL

GENERAL NOTES

SINGLE LINE DIAGRAMSCALE N.T.S.

LIGHTING LAYOUTSCALE 1:50

POWER LAYOUTSCALE 1:50

2-3.5mm²THHN,

1-2.0mm²THHN,

IN 15mmØRSC.

I

T

= 2.19AMPERES

USE: 2-5.5mm

2

THHN, 1-2.0mm

2

THHN IN 15mmØ RSC. (50/46 AMPS)

MAIN: 20AT, 50AF,2PCB,240V,10KAIC, B.O.

DO

LOAD COMPUTATIONSCALE N.T.S.

20-WATT T5 ELECTRONIC LAMP

25 WATTS PILOT LIGHT

11 WATTS EMERGENCY PINLIGHT

20-WATT T5 EMERGENCY ELECTRONIC LAMP

SHEET CONTENTS:

SHEET NO.

VICINITY MAP

LOCATION MAP

GENERAL NOTES

LEGEND

E1SINGLE LINE DIAGRAM

LOAD COMPUTATION

ELECTRICAL LAYOUTS

UNIT 222 SECOND FLR.SM CITY GEN. SAN., GENERAL SANTOS, PHILIPPINES