    EARTHING AND LIGHTNING PROTECTION

  • 1

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Copper Bond Electrode Rod (Threaded) They are made from a low carbon, high tensile strength (600m/mm2 minimum) steel core with a coating

    of molecular bonded 99.9% pure electrolytic copper.

    The minimum thickness of this coating is 100 micro (0.1 mm), 200 micro (0.2 mm), 250 micro (0.25 mm).

    Extensible type rods have a rolled thread (UNC2A at each end).

    Rolled threads have a higher strength than cut threads and also preserve the copper coating at the

    treads roots.

    Special size and copper thickness can be supplied on request.

    Part No. Length Rod Dia

    mm

    Thread Size

    ft mm in mm

    ERT 1112 4' 1200 11 1/2" 12.5

    ERT 1115 5' 1500 11 1/2" 12.5

    ERT 1118 6' 1800 11 1/2" 12.5

    ERT 1212 4' 1200 12.5 9/16" 14.2

    ERT 1215 5' 1500 12.5 9/16" 14.2

    ERT 1218 6' 1800 12.5 9/16" 14.2

    ERT 1412 4' 1200 14.2 5/8" 15.8

    ERT 1415 5' 1500 14.2 5/8" 15.8

    ERT 1418 6' 1800 14.2 5/8" 15.8

    ERT 1424 8' 2400 14.2 5/8" 15.8

    ERT 1430 10' 3000 14.2 5/8" 15.8

    ERT 1712 4' 1200 17.2 3/4" 19

    ERT 1715 5' 1500 17.2 3/4" 19

    ERT 1718 6' 1800 17.2 3/4" 19

    ERT 1724 8' 2400 17.2 3/4" 19

    ERT 1730 10' 3000 17.2 3/4" 19

  • 2

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Copper Bond Electrode Rod (Un-Threaded)

    They are made from a low carbon, high tensile strength (600m/mm2 minimum) steel core with a coating

    of molecular bonded 99.9% pure electrolytic copper.

    The minimum thickness of this coating is 100 micro (0.1 mm), 200 micro (0.2 mm), 250 micro (0.25 mm).

    Special size and copper thickness can be supplied on request.

    Part No. Length Rod Dia

    ft mm in mm

    ER 101 4' 1200 1/2" 12.5

    ER 102 5' 1500 1/2" 12.5

    ER 103 6' 1800 1/2" 12.5

    ER 144 4' 1200 9/16" 14

    ER 145 5' 1500 9/16" 14

    ER 146 6' 1800 9/16" 14

    ER 201 4' 1200 5/8" 16

    ER 202 5' 1500 5/8" 16

    ER 203 6' 1800 5/8" 16

    ER 204 8' 2400 5/8" 16

    ER 205 10' 3000 5/8" 16

    ER 301 4' 1200 3/4" 19

    ER 302 5' 1500 3/4" 19

    ER 303 6' 1800 3/4" 19

    ER 304 8' 2400 3/4" 19

    ER 305 10' 3000 3/4" 19

  • 3

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Driving Head

    Driving studs are made from high tensile steel with a

    socket head cap screw.

    Coupling

    Couplers are counter bored to completely enclose threads

    & protect from damage and corrosion

    Driving Tip

    Part No. Suitable for Rod Dia

    In mm

    DH 12 1/2" 12.5

    DH 14 9/6" 14

    DH 16 5/8" 16

    DH 19 3/4" 19

    Part No. Length (mm)

    Suitable for Rod Dia

    in mm

    CC 12 60 1/2" 12.5

    CC 16 60 9/6" 14

    CC 19 70 5/8" 16

    CC 14 70 3/4" 19

    Part No. Length (mm) Suitable for Rod Dia

    in mm

    DS 12 60 1/2" 12.5

    DS 14 60 9/6" 14

    DS 16 70 5/8" 16

    DS 19 70 3/4" 19

  • 4

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Solid Copper Grounding Rod

    Solid copper earth rod are made from 99.9% pure

    electrolytic copper. Solid copper rods offers greater

    resistance to corrosion. They are ideally used in applications

    where soil condition are very aggressive, for eg. Solid with

    high salt content.

    Driving Head

    Driving Heads are made from hardened and tempered

    steel. It is used protect the internal thread and the top of

    the earth electrode when being driven into the ground.

    Coupling Dowel

    Coupling dowels for stainless steel earth rods are made

    from stainless steel or brass. It used to join either the solid

    copper and stainless steel rods.

    Driving Spike

    Driving spikes are made from case hardened steel. It is used

    to enable the earth. Electrode to be driven into the ground

    more easily and stops the earth electrode from being

    damage.

    Part No. Rod Dia (mm) Length

    SCR-512 15 1200 mm or 4'

    SCR-515 15 1500 mm or 5'

    SCR-520 20 1200 mm or 6'

    SCR-521 20 1500 mm or 5'

    Part No. Length (mm) Thread Dia (mm) Material

    DH 16 40 10 Hardened steel DH 20 42 10

    Part No. Length Thread Dia (mm) Material

    CD 10 40 10 Stainless steel CD 10 40 10

    Part No. Length Thread Dia (mm) Material

    DS 10 40 10 Stainless steel DS 10 40 10

  • 5

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Solid Copper Earth Rod

    Solid copper earth rod are made from 99.9% pure electrolytic copper.

    Solid copper earth rod offers greater resistance to corrosion. They are ideally used in applications where

    soil conditions are very aggressive, foreg, soil with high salt content.

    Mechanically Claded Earth Rod

    Mechanically cladded copper earth rod is made from 99.9% electrolytic grade copper tube with wall

    thickness of 0.25 mm (25 micro) is cladded to a low carbon steel rod.

    Part No. Length Rod Dia

    ft mm in mm

    CR 101 4' 1200 1/2" 12.5

    CR 102 5' 1500 1/2" 12.5

    CR 144 4' 1200 9/16" 14

    CR 145 5' 1500 9/16" 14

    CR 201 4' 1200 5/8" 16

    CR 202 5' 1500 5/8" 16

    CR 203 6' 1800 5/8" 16

    Part No. Length Rod Dia

    ft mm in mm

    ER 101 4' 1200 1/2" 12.5

    ER 102 5' 1500 1/2" 12.5

    ER 144 4' 1200 9/16" 14.2

    ER 145 5' 1500 9/16" 14.2

    ER 201 4' 1200 5/8" 16

    ER 202 5' 1500 5/8" 16

    ER 203 6' 1800 5/8" 16

    ER 302 5' 1500 3/4" 19

    ER 303 6' 1800 3/4" 19

  • 6

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Rod to Tape Clamp

    The clamps are used to join various sizes of conductor tape to

    the earth electrode, which have a high resistance to

    corrosion and are mechanically strong to ensure a lasting

    connection.

    Rod to Cable Clamp

    The clamps are used to join various sizes of cable to the earth

    electrode, which have a high resistance to corrosion and are

    mechanically strong to ensure a lasting connection.

    Part No. Rod Dia

    Max. Conductor in mm

    RTC 10 1/2" 12.5 26 x 12 mm2

    RTC 10 5/8" 16 26 x 12 mm2

    RTC 10 3/4" 19 26 x 10 mm2

    RTC 30 5/8" 16 40 x 12 mm2

    RTC 40 5/8" 16 51 x 8 mm2

    RTC 50 3/4" 19 51 x 12 mm2

    RTC 60 1/2" 12.5 26 x 20 mm2

    RTC 60 5/8" 16 26 x 18 mm2

    RTC 60 3/4" 19 26 x 10 mm2

    RTC 60 1" 25 26 x 10 mm2

    Part No. Rod Dia

    Max. Conductor in mm

    RCC 9 3/8" 9.5 6-35 mm2

    RCC 12 1/2" 12.5 16-50 mm2

    RCC 16 5/8" 16 16-70 mm2

    RCC 20 3/4" 19 16-95 mm2

    RCC 25 1" 25 70-120 mm2

  • 7

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    U-Bolt Rod to tape Clamp (Single Plate)

    The clams are used to join various sizes of conductor

    tape to earth electrode / rebar.

    U-Bolt Rod to tape Clamp (Double Plate)

    The clams are used to join 25 x 3 mm conductor tape to

    earth electrode / rebar, without the need to drill the

    tape.

    Part No. Rod Dia

    Material in Mm

    URC-1-16 5/8" 16

    Copper/Brass URC-1-20 3/4" 20

    URC-1-25 1 25

    Part No. Rod Dia

    Material in Mm

    URC-2-16 5/8" 16

    Copper/Brass URC-2-20 3/4" 20

    URC-2-25 1 25

  • 8

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    U-Bolt Rod to Cable Clamp

    U-Bolt Rod Clamp

    Part No. Rod/Pipe Dia No. of

    Conductors Conductor Size

    (mm2) No. of Copper Tape

    in mm

    UC 301 5/8"-3/4" 16-19 1 50-95 -

    UC 302 5/8"-3/4" 16-19 2 50-70 -

    UC 303 5/8"-3/4" 16-19 3 50-70 -

    UC 304 5/8"-3/4" 16-19 5 50-70 -

    UC 305 5/8"-3/4" 16-19 3 70-120 -

    UC 306 5/8"-3/4" 16-19 2 50-70 -

    UC 307 5/8"-3/4" 16-19 1 70-120 -

    UC 308 5/8"-3/4" 16-19 - - 1 or 2

    UC 309 - 30 - - 1 or 2

    UC 310 - 40 - - 1

    Part No. Rod Dia

    (mm) Conductor

    (mm2) Material

    URCC 16 14.2-17.2 16-70 Copper/Brass

    URCC 70 18-25 70-185

  • 9

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Tape Clip

    These Metal Clip Hold the Tape Flush to the Surface

    and Fixed Using Two Screws

    Tape Clip

    DC Tape Clamp

    DC Tape Clamp

    Part No. Conductor Size

    (mm) Material

    TCC 203 20 x 3 Copper/Brass

    TCC 253 25 x 3

    Part No. Conductor Size

    (mm) Material

    TCA 203 20 x 3 Aluminium

    TCA 253 25 x 3

    Part No. Tape Size (mm) Material

    ADC 203 20 x 3

    Aluminium ADC 253 25 x 3

    ADC 256 25 x 6

    ADC 506 50 x 6

    Part No. Conductor (mm) Material

    CDC 203 20 x 3

    Copper/Brass

    CDC 253 25 x 3

    CDC 256 25 x 6

    CDC 503 50 x 3

    CDC 504 50 x 4

    CDC 506 50 x 6

  • 10

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Square Tape Clamp

    Square clamps are made form cooper and aluminium,

    it is used for four ways connection and suitable for

    crossing over taps, straight through joints or t

    connections to from a continuous network of tapes.

    Square Conductor Clamp

    Square clamps for copper and aluminium circular

    conductor used for a four ways connection and

    suitable for crossing over taps, straight through joints

    or t connections to from a continuous network of

    tapes.

    Part No. Conductor Size

    (mm2) Material

    ASC 253 25 x 3 Aluminium

    CSC 253 25 x 3

    Copper/Brass CSC 256 25 x 6

    CSC 506 50 x 6

    Part No. Conductor Size

    (mm2) Material

    SCC 50 50

    Copper SCC 50 70

    SCC 50 95

  • 11

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Bi-Metallic Connector

    Part No. Conductor Size

    (mm2) Material

    BMC 253 B 25 x 3 Aluminium Tape to

    25 x 3 Copper Tape

    Bimetal Clamps are used to connect Aluminium conductor to Copper Earth Conductor

    Adhesive Base DC Clip

    Part No. Conductor Size

    (mm2) Material

    BMC 253 A 25 x 3 Aluminium Tape to

    25 x 3 Copper Tape

    Part No. Conductor Dia

    (mm) Conductor Type

    OH 8 C 8 Copper

    OH 8 A 8 Aluminium

    OH 10 C 8 Copper pvc covered

    OH 10 A 8 Aluminium pvc covered

  • 12

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    C-Copper Clamp

    Material : 99.9% Pure coppen Surface : Tin Plating on request

    Split Bolted Connector

    Material : Brass Surface : Tin Plated or Copper Plated on request. It is used to branch or connect aerial hard copper conductor or insulated copper conductor.

    Part No.

    Conductor (mm

    2)

    Dimensions (mm) Note

    H B L C

    CCA-1 25-35 25 15 22 10 Can be produced

    according to customer's

    drawing

    CCA-2 50-70 34 21.5 25 11

    CCA-3 95-95 41 25 29 14.5

    CCA-4 120-120 47.5 29 30 16

    Part No. Conductor

    (mm2)

    Dimensions (mm)

    H A B L C T

    CCT-10 7.5-14 9.5 6.3 6.2 12 4 1.6

    CCT-16 14.5-16 11.8 7.8 7.8 13 5 2

    CCT-20 16.5-20 12.8 8.6 9.7 13 5.4 2.9

    CCT-26 21-26 14.7 10.2 10 16 6.5 3.2

    CCT-44 27-44 19 13.4 14.4 20 8.5 4

    CCT-60 45-60 21 15.4 15.4 22 9.7 4

    CCT-76 61-75 24.4 17.3 17.6 22 10.8 5

    CCT-98 77-98 27.8 20.8 18.8 25 12.8 5

    CCT-122 99-122 29.8 22.1 21.2 26 13.5 5.5

    CCT-154 123-154 34 25.7 24.4 28 17 6

    CCT-190 155-190 37 28.5 25.4 35 17.4 6

    CCT-240 191-240 40 30.2 28.5 40 19 7

    Part No. Applicable Conductor

    (mm2)

    Dimensions (mm) Weight (kg) L M H S

    T/J-16 16 26 10 x 1 5.3 13.9 0.023

    T/J-25 25 29 14 x 1.5 7 18.5 0.034

    T/J-35 35 34 18 x 1.5 8 20.8 0.057

    T/J-50-70 50-70 42 24 x 2 12 27.7 0.108

    T/J-90-120 90-120 50 24 x 2 14.5 30 0.142

    T/J-150-185 150-180 63 24 x 2 18 34.6 0.250

    T/J-200-240 200-240 72 31 x 2.5 20 32 0.301

  • 13

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    B Bond

    Bond connections are used to bond either Copper of Aluminium to flat metal surfaces.

    Pipe Bond

    Pipe bond connections are used to connect flat conductor objects i.e. Pipe work and hand rails etc.

    Rod to Cable Lug Clamp

    Rod to cable lug clamps are used to join various sizes of compression lugs to the earth electrode.

    Part No. Conductor

    (mm) Material

    BBC 25 x 3 Copper/Brass

    BBA 25 x 3 Aluminium

    Part No. Conductor

    (mm) Material

    PBC 25 x 3 Copper/Brass

    PBA 25 x 3 Aluminium

    Part No. Rod Dia

    Material in mm

    CLUG 10 3/8" 9.5

    Copper/Brass CLUG 16 5/8" 16

    CLUG 20 S - 20

  • 14

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Tee Clamp

    Tee clamps for copper and aluminium circular conductor, the clamps are used for three ways connection.

    Flat to Circular Square Clamp

    Square clamps for copper tape to circular conductor, the base has a countersunk hole in the middle for fixing the clamp.

    Test ClampCable

    Test clamps are manufactured from copper, it used to form a disconnecting joint between the down conductor system and the earthing system.

    Part No. Conductor Dia

    (mm) Material

    TC 08 8 Copper/Brass

    TA 08 8 Aluminium

    Part No. Tape Size

    (mm) Conductor Rang

    (mm/mm2) Material

    SCC 25350 25 x 3 50

    Copper/Brass SCC 25370 25 x 3 70

    SCC 25395 31 x 3 95

    Part No. Conductor Dia (mm) Material

    TC 50 50

    Copper/Brass TC 70 70

    TC 95 95

  • 15

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Oblong Test Clamp

    Oblong Test Clamps are used to join conductor tape to facilitate in the annual testing of the lightning protection system.

    Copper Test Clamp

    Copper test clamp are used to form a disconnecting joint between either conductor (8 mm + 0.8 mm dia) or 25 x 3 m conductor.

    Earth Bonding Point

    Earth bond points are used to provide earthing continuity and a multi-bonding point. The bonding points are available with 2 or 4 holes connections and cover plate.

    Part No. Conductor (mm) Material

    OTCA 253 25 x 3 Aluminium

    OTCC 253 25 x 3

    Copper/Brass OTCC 316 31 x 6

    OTCA 405 40 x 5

    Part No. Conductor Dia

    (mm) Conductor Size

    (mm) Material

    CTC 08 8 25 x 3 Copper/Brass

    Part No. Length (mm)

    Material

    EBP 2 500

    Gunmetal casting with 70 mm2 pvc copper cable

    EBP 4 500

    EBP 2P 500

    EBP 2P-08 500

  • 16

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Screw Down Test Clamp

    Screw down test clamp are used to join 25 x 3 mm conductor tape to facilitate in the annual testing of the lightning protection system.

    Plate Test Clamp

    Plate type test clamps, made of brass or aluminium, which can be used as to joints or straight through joints of tapes being joints, these can also effectively be used as testing points for the network. By disconnecting the joints, plate test clamp can also be used for heavy duty up to 50 x 6 tape connections.

    Part No. Conductor (mm) Material

    STDC 253 25 x 3 Copper/Brass

    Part No. Conductor (mm) Material

    PTC 253 25 x 3 Gunmetal

  • 17

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Air Rod

    The air rods made from Electrocytic Grade Copper, one side tapper pointed and the other side with suitable threads for fixing to saddles /air terminal bases. Rods made from also can be supplied against specific requirements. Rods can be installed with or without multiple points. However, researches conducted in this regards suggest use or multiple points with taper pointed air rods are more effective than taper pointed air rods.

    Air Rods Base

    Copper and Aluminium Air Rod Base are used for supporting taper pointed or air Rods with tapes, four fixing holes are provided on it.

    Part No. Rod Length

    (mm) Rod Dia

    (mm) Thread Dia

    (mm) Material

    CAR 0515 500 15 16

    Copper CAR 1015 1000 15 16

    CAR 1515 1500 15 16

    CAR 2015 2000 15 16

    TAR 515 T 500 15 16

    Tinned Copper TAR 1515 T 1000 15 16

    TAR 2015 T 1500 15 16

    TAR 051 T 2000 15 16

    AAR 0515 A 500 15 16

    Aluminium AAR 1015 A 1000 15 16

    AAR 1515 A 1500 15 16

    AAR 2015 A 2000 15 16

    AAR 0510 500 10 10 Copper

    AAR 1010 1000 10 10

    AAR 0510 A 500 10 10 Aluminium

    AAR 1010 A 1000 10 10

    Part No. Rod Dia

    (mm) Thread Dia

    (mm)

    Max. Conductor

    width (mm) Material

    DC 312 12 12 25 Copper/Brass

    DC 515 15 16 25

    DA 312 12 12 25 Aluminium

    DA 515 15 16 25

  • 18

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Air Termination

    Tapper pointed air rods ate made from copper/base. One side tapper pointed and the other side with suitable for fixing to saddles/air terminal bases. Rods made of aluminium alco can be supplied against specific requirements. Rod can be use of multiple points with taper points with taper pointed air rods are more effective than taper pointed air rods.

    Part No. Rod Length

    (mm) Rod Dia

    (mm) Thread Dia

    (mm) Material

    ATC 3142 300 14.2 5/8"

    Copper/Brass ATC 5142 500 14.2 5/8"

    ATC 10142 1000 14.2 5/8"

    ATC 20142 2000 14.2 5/8"

    ATC 31558-16 300 15 5/8' or 16 mm

    Copper/Brass

    ATC 51558-16 500 15 5/8' or 16 mm

    ATC 101558-16 1000 15 5/8' or 16 mm

    ATC 201558-16 2000 15 5/8' or 16 mm

    ATC 31658-16 300 16 5/8' or 16 mm

    ATC 51658-16 500 16 5/8' or 16 mm

    ATC 101658-16 1000 16 5/8' or 16 mm

    ATC 201658-16 2000 16 3/4'

    ATC 5172 500 17.2 3/4'

    Copper/Brass ATC 10172 1000 17.2 3/4'

    ATC 20172 2000 17.2 5/8'

    ATA 3142 300 14.2 5/8'

    Aluminium

    ATA 5142 500 14.2 5/8'

    ATA 10142 1000 14.2 5/8'

    ATA 15142 1500 14.2 5/8'

    ATA 20142 2000 14.2 5/8' or 16 mm

    ATA 31558-16 300 15 5/8' or 16 mm

    Aluminium

    ATA 51558-16 500 15 5/8' or 16 mm

    ATA 101558-16 1000 15 5/8' or 16 mm

    ATA 151558-16 1500 15 5/8' or 16 mm

    ATA 201558-16 2000 15 5/8' or 16 mm

    ATA 31658-16 300 16 5/8' or 16 mm

    Aluminium

    ATA 51658-16 500 16 5/8' or 16 mm

    ATA 101658-16 1000 16 5/8' or 16 mm

    ATA 151658-16 1500 16 5/8' or 16 mm

    ATA 201658-16 2000 16 3/4'

    ATA 5172 500 17.2 3/4'

    Aluminium ATA 10172 1000 17.2 3/4'

    ATA 20172 2000 17.2

  • 19

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Air Termination

    Part No. Dimensions (mm)

    H H1 H2 H3 D

    ATC 01-A 380 250 130 90 100

    ATC 01-B 550 420 130 140 100

    ATC 01-C 1000 870 130 300 100

    Part No. Dimensions (mm)

    H H1 H2 H3 D

    ATC 02-A 380 250 130 90 100

    ATC 02-B 550 420 130 140 100

    ATC 02-C 1000 870 130 300 100

    Part No. Dimensions (mm)

    H H1 H2 H3

    ATC 03-A 750 400 250 100 100

    Part No. Dimensions (mm)

    H H1 H2 H3 1 2

    ATC 03-B 1500 250 200 700 150 200

  • 20

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Earth Plate Solid Copper

    Solid copper earth plates are used as part of earthing network, which provide a log lasting solution where earth rods are unsuitable and also used as an electrode where significant amounts of fault current can be encountered.

    Earth Mat Copper Tape

    The Copper Earth Mat are used where step potential could cause problems, which provide a long lasting earthing solution and used as an electrode where significant amounts of fault current can be encountered. Solid copper plate arrangement Lattice copper mat arrangement

    Part No. Size (mm) Material

    SCEP 615 600 x 600 x 1.5

    Copper SCEP 630 600 x 600 x 3

    SCEP 915 900 x 900 x 1.5

    SCEP 930 900 x 900 x 3

    Part No. Size (mm) Material

    LCEM 630 600 x 600 x 3 High conductivity copper

    LCEM 930 900 x 900 x 3

  • 21

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Rod To Tape Coupling

    Rod To Tape Couplers are made from copper and used in conjunction with Side Mounted Brackets.

    Air Rod Bracket

    Air Rod Brackets are to be installed to the side of the building were it is not possible to fit a conventional air terminal base. The brackets are to be used in conjunction with the rod to tape coupling.

    Puddle Flanges

    Made from copper or Aluminium, used where the roof termination or down conductors have to pass through water proof couering, roff, etc.

    Part No. Conductor Dia

    (mm) Conductor Size

    (mm) Material

    RBCC 16 16 25 x 3 Copper/Brass

    Part No. Conductor Dia

    (mm) Conductor Size

    (mm) Material

    APK 15 15 16 Copper

    APK 15 A 15 16 Aluminium

    APK 15 T 15 16 Tinned Copper

    Part No. Dimension (mm) Material

    PFC 150 x 150 x 600 Copper

    PFA 150 x 150 x 600 Aluminium

  • 22

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Compression Clamp

    Inspection Pit

    These are suitable for most types of earthing & lightning protection installations. Not suitable for use in areas where high load, small wheel vehicles are used.

    Product Introduction

    Part No. Diameter of lamp Height of Lamp Length of screw Material

    IP 5 160 mm 185 mm 200 mm M16

    The obstruction lamp is a product applied by the communication base stations up to date since a long time ago. It is based on DC or AC power as its power supply system with the light emitting tube as its light source. Its outside case is made of polycarbonate and engineering plastic materials, controlled with the light sensitive resistance. It flashes by itself at the night time and turns off automatically at the day time.

    Part No. Suitable Conductor (mm2)

    BC-119-50 50-70

    BC-119-70 70-95

    BC-119-95 95-120

    Part No. Overall (mm) Description Material

    IP 5 300 x 25 x 6 5 Hole pit bar Hard drawn copper bar IP 7 300 x 25 x 6 7 Hole pit bar

  • 23

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Earth Bars

    Other sizes request

    Earth Bars Insulators

    Electrical : Dielectric Strength : > 14 kV/mm Resistance (normal) : > 10 M Ohms Resistance (bolted) : > 10 M Ohms Arc resistance : > 180 secretary Tracking Index : > 600 Inserts: Brass M6 9 Nm Torque (Torque can depend M8 18 Nm Torque on the Standoff M10 35 Nm Torque diameter)

    Part No. Dimension (mm2) Material

    EBAR 6 300 x 90 x 90 6 ways earth bar disconnect link

    EBAR 8 450 x 90 x 90 8 ways earth bar disconnect link

    EBAR 10 450 x 90 x 90 10 ways earth bar disconnect link

    EBAR 12 520 x 90 x 90 12 ways earth bar disconnect link

    EBAR 14 650 x 90 x 90 14 ways earth bar disconnect link

    EBAR 16 650 x 90 x 90 16 ways earth bar disconnect link

    EBAR 18 800 x 90 x 90 18 ways earth bar disconnect link

    EBAR 20 800 x 90 x 90 20 ways earth bar disconnect link

    EBAR 22 900 x 90 x 90 22 ways earth bar disconnect link

    EBAR 24 1050 x 90 x 90 24 ways earth bar disconnect link

    EBAR 26 1050 x 90 x 90 26 ways earth bar disconnect link

    EBAR 28 1250 x 90 x 90 28 ways earth bar disconnect link

    EBAR 30 1250 x 90 x 90 30 ways earth bar disconnect link

    Part No. Size (mm) Description

    SM 10 M 10 x 35 Insulator stand off type c/w 2 studs & 3 nuts

    SM 20 M 5 x 20 Insulator stand off type

    SM 25 M 6 x 25 Insulator stand off type

    SM 30 M 8 x 30 Insulator stand off type

    SM 35 M 8 x 35 Insulator stand off type

    SM 40 M 8 x 40 Insulator stand off type

    SM 45 M 8 x 45 Insulator stand off type

    SM 51 M 8 x 51 Insulator stand off type

    SM 60 M 8 x 60 Insulator stand off type

    SM 76 M 10 x 71 Insulator stand off type

  • 24

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Copper Tape

    Part No. Dimension (mm2) Stand No. / Diameter

    (mm2) Remark

    CT 203 20 x 3 60

    Material : Oxygen-free copper

    CT 254 25 x 4 100

    CT 304 30 x 4 120

    CT 305 30 x 5 150

    CT 404 40 x 4 160

    CT 405 40 x 5 200

    CT 505 50 x 5 250

    CT 506 50 x 6 300

    Bi-metal Earth Conductor

    Part No. Diameter (mm) Length (m) Remark

    SBCT 08 8 6

    SBCT 10 10 6 Thickness of copper layer 0.5 mm Copper/steel SBCT 12 12 6

    SBCT 14 14 6

    Flat Bi-metal Tape

    Part No. Dimensions

    (mm) Stand No. / dia (m) Remark

    FBT 50 6 X 14 6

    FBT 070 6 X 20 6

    FBT 095 7 X 22 6

    FBT 120 7 X 27 6 Thickness of copper layer 0.5 mm Copper/steel FBT 160 7 X 32 6

    FBT 180 7 X 37 6

    FBT 210 8 X 37 6

  • 25

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Bi-metal Earthing Conductor Barel (Cu/Steel) Bimetallic cable / Y/G PVC insulated (Cu/Steel) Bimetallic cableGalvanized technics.

    Part No. Conductor Section

    (mm2) Conductor Dia

    (mm) Weight / M

    (kgs) Remark

    BC 16/IBC 16 16 7/1.70 0.126/0.156

    BC 25/IBC 25 25 7/2.14 0.193/0.228

    BC 35/IBC 35 35 7/2.50 0.273/0.323

    BC 50/IBC 50 50 7/3.00 0.384/0.444 General packing : 100 meters BC 50/IBC 50 50 19/1.80 0.384/0.444

    BC 70/IBC 70 70 19/2.10 0.523/0.603 Voltage of Insulator : 450/750V BC 95/IBC 95 95 19/2.50 0.742/0.842

    BC 120/IBC 120 120 37/2.03 0.930/1.050

    BC 150/IBC 150 150 37/2.30 1.02/1.17

    BC 185/IBC 185 185 37/2.50 1.446/1.63

    Copper Earth Conductor Bare copper stranded cables / Y / G PVC insulated copper cables.

    Part No. Conductor Section

    (mm2)

    Conductor Dia (mm)

    Weight / M (kgs)

    Remark

    CC 16/ICC 16 16 7/1.68 0.14/0.17

    Cc 25/ICC 25 25 7/2.11 0.22/0.255

    Cc 35/ICC 35 35 7/2.49 0.306/0.356

    Cc 50/ICC50 50 7/2.97 0.438/0.498 Material : Oxygen-

    Cc 70/ICC 70 70 19/2.14 0.618/0.698 free copper

    Cc 95/ICC 95 95 19/2.49 0.838/0.938 tinned conductor

    Cc 120/ICC 120 120 19/2.80 1.057/1.177 on request

    Cc 150/ICC 150 150 37/2.25 1.34/1.49

    Cc 185/ICC 185 185 37/2.49 1.65/1.834

    Cc 240/ICC 240 240 37/2.84 2.14/2.371

    Cc 300/ICC 300 300 61/2.49 3.564/2.854

  • 26

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Copper Braid Wire The copper braided wire is used as flexible jointing wire of electric appliance, switch appliance, electric stove and storage battery etc. Model and Meaning Technique Performance Copper braided wire adopts super quality round copper wire or tinning soft round copper wire to be braided in multiple thread one layer or many layers. The DC electrical resistivity (20oC) of copper braided wire is lower than 0.022 .mm2/m, the DC electrical resistivity (200C) of tinning copper braided wire is lower than 0.234 .mm2/m.

    CBW20 and CBWX 20

    Section (mm2) Number of skeins x

    threads/diameter of a single thread (mm)

    Size (mm)

    20 Direct Current reistance /km no

    more than Calculating

    weight (kg/km)

    Standard Calculating The width no more

    than

    Thickness for

    reference CBW-20 CBWX-20

    16 16.59 24 x 22 x1/0.20 16 3.0 1.30 1.36 166

    25 24.88 24 x 33 x1/0.20 18 3.5 0.87 0.91 249

    35 33.18 24 x 44 x1/0.20 20 4.0 0.65 0.68 331

    50 49.77 24 x 33 x2/0.20 22 5.0 0.43 0.45 198

    70 66.36 24 x 44 x2/0.20 24 6.5 0.32 0.33 664

    95 90.49 24 x 40 x3/0.20 20 - 0.24 0.25 905

    120 120.55 24 x 40 x4/0.20 22 - 0.18 0.19 1207

    150 150.82 24 x 40 x 5/0.20 24 - 0.14 0.15 1508

    185 180.98 24 x 40 x 6/0.20 26 - 0.12 0.13 1810

    240 241.31 24 x 40 x 8/0.20 30 - 0.089 0.093 2413

    300 301.63 24 x 40 x 10/0.20 35 - 0.071 0.075 3016

    400 401.17 24 x 40 x 10/0.20 + 36 x 44 x 2/0.20 40 - 0.054 0.056 4004

    500 500.65 24 x 40 x 10/0.20 + 48 x 44 x 3/0.20 45 - 0.043 0.045 5007

    630 633.43 24 x 40 x 10/0.20 + 48 x 44 x 5/0.20 50 - 0.034 0.036 6334

  • 27

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Copper Braided Shunt

    These connectors manufactured from highly flexible, which are braided from annealed Cu. The best alternative to cable, no cutting, no crimping, flexible, pre-punched, ready to use, quick and easy to install. Solidified pressed contact areas Ametal Alloyed Leadfree Solder Solidified Contact Areas Technical data Braids : 0.20 mm annealed Cu-ETP wires, uncoated or tinned Insulation : Special vinyl compound Max. working temperature 1050C Self extinguishable: UL 94 VO Dielectric strength : 20 kV/mm Max. working voltage : 1000V AC 1500 V DC

  • 28

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Part No. Cross secretary

    (mm2)

    Dimensions

    Red Copper Tinned Copper L

    mm L1

    mm L2

    mm L3

    mm L4

    mm L5

    mm W

    mm T

    mm K

    mm G

    mm D1

    mm D2

    mm

    BS 025- 230- 10-8 BST 025- 230- 10-8 25 230 25 25 11 7 248 20 3.2 7 23 10 8.5

    BS 025- 330- 10-8 BST 025- 330- 10-8 25 330 25 25 11 7 348 20 3.2 7 23 10 8.5

    BS 025- 430- 10-8 BST 025- 430- 10-8 25 430 25 25 11 7 448 20 3.2 7 23 10.5 8.5

    BS 025- 530- 10-8 BST 025- 530- 10-8 25 530 25 25 11 7 548 20 3.2 7 23 10.5 8.5

    BS 025- 630- 10-8 BST 025- 630- 10-8 25 630 25 25 11 7 648 20 3.2 7 23 10.5 8.5

    BS 025- 230- 10-8 BST 025- 230- 10-8 25 230 25 25 11 7 248 20 4.2 7 23 10.5 8.5

    BS 035- 330- 10-8 BST 035- 330- 10-8 35 330 25 25 11 7 348 20 4.2 7 23 10.5 8.5

    BS 035- 430- 10-8 BST 035- 430- 10-8 35 430 25 25 11 7 448 20 4.2 7 23 10.5 8.5

    BS 035- 530- 10-8 BST 035- 530- 10-8 35 530 25 25 11 7 548 20 4.2 7 23 10.5 8.5

    BS 035- 630- 10-8 BST 035- 630- 10-8 35 630 25 25 11 7 648 20 4.2 7 23 10.5 8.5

    BS 035- 230- 10-8 BST 035- 230- 10-8 35 230 25 25 11 7 252 20 5 7.5 23 10.5 8.5

    BS 050- 330- 10-8 BST 050- 330- 10-8 50 330 25 25 11 7 352 20 5 7.5 23 10.5 8.5

    BS 050- 430- 10-8 BST 050- 430- 10-8 50 430 25 25 11 7 452 20 5 7.5 23 10.5 8.5

    BS 050- 530- 10-8 BST 050- 530- 10-8 50 530 25 25 11 7 552 20 5 7.5 23 10.5 8.5

    BS 050- 630- 10-8 BST 050- 630- 10-8 50 630 25 25 11 11 652 20 5 7.5 23 10.5 10.5

    BS 050- 230- 10-8 BST 050- 230- 10-8 50 230 25 25 11 11 252 20 6.8 8.5 23 10.5 10.5

    BS 070- 330- 10-10 BST 070- 330- 10-10 70 330 25 25 11 11 352 20 6.8 8.5 23 10.5 10.5

    BS 070- 430- 10-10 BST 070- 430- 10-10 70 430 25 25 11 11 452 20 6.8 8.5 23 10.5 10.5

    BS 070- 530- 10-10 BST 070- 530- 10-10 70 530 25 25 11 11 552 20 6.8 8.5 23 10.5 10.5

    BS 070- 630- 10-10 BST 070- 630- 10-10 70 630 25 25 11 11 652 20 6.8 8.5 23 10.5 10.5

    BS 070- 230- 10-10 BST 070- 230- 10-10 70 230 25 25 11 11 252 25 7.5 8.5 28 10.5 10.5

    BS 095- 330- 10-10 BST 095- 330- 10-10 95 330 25 25 11 11 352 25 7.5 8.5 28 10.5 10.5

    BS 095- 430- 10-10 BST 095- 430- 10-10 95 430 25 25 11 11 452 25 7.5 8.5 28 10.5 10.5

    BS 095- 530- 10-10 BST 095- 530- 10-10 95 530 25 25 11 11 552 25 7.5 8.5 28 10.5 10.5

    BS 095- 630- 10-10 BST 095- 630- 10-10 95 630 25 25 11 11 652 25 7.5 8.5 28 10.5 10.5

    BS 120- 330- 10-10 BST 120- 330- 10-10 120 330 30 30 11 14 355 30 7.5 12.5 28 10.5 10.5

    BS 120- 430- 10-10 BST 120- 430- 10-10 120 430 30 30 11 14 455 30 7.5 12.5 28 10.5 10.5

    BS 120- 530- 10-10 BST 120- 530- 10-10 120 530 30 30 11 14 555 30 7.5 12.5 28 10.5 10.5 BS 120- 630- 10-10 BST 120- 630- 10-10 120 630 30 30 11 14 655 30 7.5 12.5 28 10.5 10.5

    BS 120- 730- 10-10 BST 120- 730- 10-10 120 730 30 30 11 14 755 30 7.5 12.5 28 10.5 10.5

    BS 120- 830- 10-10 BST 120- 830- 10-10 120 830 30 30 11 14 855 30 7.5 12.5 28 10.5 10.5

    BS 150- 330- 10-12 BST 150- 330- 10-12 150 330 30 30 14 14 355 30 10 15 34 12.5 12.5

    BS 150- 430- 10-12 BST 150- 430- 10-12 150 430 30 30 14 14 455 30 10 15 34 12.5 12.5

    BS 150- 530- 10-12 BST 150- 530- 10-12 150 530 30 30 14 14 555 30 10 15 34 12.5 12.5

    BS 150- 630- 10-12 BST 150- 630- 10-12 150 630 30 30 14 14 655 30 10 15 34 12.5 12.5

    BS 150- 730- 10-12 BST 150- 730- 10-12 150 730 30 30 14 14 755 30 10 15 34 12.5 12.5

    BS 150- 830- 10-12 BST 150- 830- 10-12 150 830 30 30 14 14 855 30 10 15 34 12.5 12.5

    BS 185- 330- 10-12 BST 185- 330- 10-12 185 330 30 30 14 14 355 30 11 15 34 12.5 12.5

    BS 185- 430- 10-12 BST 185- 430- 10-12 185 430 30 30 14 14 455 30 11 15 34 12.5 12.5

    BS 185- 530- 10-12 BST 185- 530- 10-12 185 530 30 30 14 14 555 30 11 15 34 12.5 12.5

    BS 185- 630- 10-12 BST 185- 630- 10-12 185 630 30 30 14 14 655 30 11 15 34 12.5 12.5

    BS 185- 730- 10-12 BST 185- 730- 10-12 185 730 30 30 14 14 755 30 11 15 34 12.5 12.5

    BS 185- 830- 10-12 BST 185- 830- 10-12 185 830 30 30 14 14 855 30 11 15 34 12.5 12.5

    BS 240- 330- 10-12 BST 240- 330- 10-12 240 330 30 30 14 14 355 30 13 17 34 12.5 12.5

    BS 240- 430- 10-12 BST 240- 430- 10-12 240 430 30 30 14 14 455 30 13 17 34 12.5 12.5

    BS 240- 530- 10-12 BST 240- 530- 10-12 240 530 30 30 14 14 555 30 13 17 34 12.5 12.5

    BS 240- 630- 10-12 BST 240- 630- 10-12 240 630 30 30 14 14 655 30 13 17 34 12.5 12.5

    BS 240- 730- 10-12 BST 240- 730- 10-12 240 730 30 30 14 14 755 30 13 17 34 12.5 12.5

    BS 240- 830- 10-12 BST 240- 830- 10-12 240 830 30 30 14 14 855 30 13 17 34 12.5 12.5

  • 29

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Grounding Braid

    Earthing Tapes With Solder Pressed Contact Areas

    Earthing Tapes With Ametal Alloyed Leadfree Solder Solidified Contact Areas

    Part No. Tinned Copper Section (mm2)

    Wire Diameter

    Dimensions

    A mm

    B mm

    C mm

    D mm

    S mm

    L mm

    TZ 6 - 75/010/07 TZX 6 - 75/010/07 6 0.10 13 11 5 7 2.0 75

    TZ 6 - 100/010/07 TZX 6 - 100/010/07 6 0.10 13 11 5 7 2.0 100

    TZ 6 - 150/010/07 TZX 6 - 150/010/07 6 0.10 13 11 5 7 2.0 150

    TZ 6 - 200/010/07 TZX 6 - 200/010/07 6 0.10 13 11 5 7 2.0 200

    TZ 10 - 100/020/09 TZX 10 - 100/020/09 10 0.15 23 17 10 9 2.0 100

    TZ 10 - 150/020/09 TZX 10 - 150/020/09 10 0.15 23 17 10 9 2.0 150

    TZ 10 - 200/020/09 TZX 10 - 200/020/09 10 0.15 23 17 10 9 2.0 200

    TZ 10 - 250/020/09 TZX 10 - 250/020/09 10 0.15 23 17 10 9 2.0 250

    TZ 10 - 300/020/09 TZX 10 - 300/020/09 10 0.15 23 17 10 9 2.0 300

    TZ 16 - 100/020/09 TZX 16 - 100/020/09 16 0.20 23 17 10 9 2.5 100

    TZ 16 - 200/020/09 TZX 16 - 200/020/09 16 0.20 23 17 10 9 2.5 200

    TZ 16 - 250/020/09 TZX 16 - 250/020/09 16 0.20 23 17 10 9 2.5 250

    TZ 16 - 300/020/09 TZX 16 - 300/020/09 16 0.20 23 17 10 9 2.5 300

    TZ 16 - 350/020/09 TZX 16- 350/020/09 16 0.20 23 23 10 9 2.5 350

    TZ 16 - 400/020/09 TZX 16 - 400/020/09 16 0.20 23 23 10 9 2.5 400

    TZ 25 - 100/020/09 TZX 25 - 100/020/09 25 0.20 23 17 10 9 3.2 100

    TZ 25 - 200/020/09 TZX 25 - 200/020/09 25 0.20 23 17 10 9 3.2 200

    TZ 25 - 300/020/09 TZX 25 - 300/020/09 25 0.20 23 17 10 9 3.2 300

    TZ 25 - 400/020/09 TZX 25 - 400/020/09 25 0.20 23 17 10 9 3.2 400

    TZ 35 - 100/020/09 TZX 35 - 100/020/09 35 0.20 23 23 10 9 3.4 100

    TZ 35 - 200/020/09 TZX 35 - 200/020/09 35 0.20 23 23 10 9 3.4 200

    TZ 35 - 300/020/09 TZX 35 - 300/020/09 35 0.20 23 23 10 9 3.4 300

    TZ 35 - 400/020/09 TZX 35 - 400/020/09 35 0.20 23 23 10 9 3.4 400

    TZ 50 - 100/020/11 TZX 50 - 100/020/11 50 0.20 30 23 10 9 4.5 100

    TZ 50 - 200/020/11 TZX 50 - 200/020/11 50 0.20 30 30 15 11 4.5 200

    TZ 50 - 300/020/11 TZX 50 - 300/020/11 50 0.20 30 30 15 11 4.5 300

    TZ 50 - 400/020/11 TZX 50 - 400/020/11 50 0.20 30 30 15 11 4.5 400

    TZ 75 - 200/020/11 TZX 75 - 200/020/11 75 0.20 30 30 15 11 5.0 200

    TZ 75 - 300/020/11 TZX 75 - 300/020/11 75 0.20 30 35 15 11 5.0 300

    TZ 75 - 400/020/11 TZX 75 - 400/020/11 75 0.20 30 35 15 11 5.0 400

    TZ 95 - 200/020/13 TZX 95 - 200/020/13 100 0.20 35 35 15 13 6.0 200

    TZ 95 - 250/020/13 TZX 95 - 250/020/13 100 0.20 35 35 15 13 6.0 250

    TZ 95 - 400/020/13 TZX 95 - 400/020/13 100 0.20 35 35 15 13 6.0 400

    TZ 95 - 400/020/13 TZX 95 - 400/020/13 100 0.20 35 35 15 13 6.0 700

  • 30

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Round Flexible Copper Wire

    Standard Section (mm2)

    Calculating Section (mm2)

    Size (mm) Calculating

    external diameter

    (mm)

    20 Direct Current reistance /km no

    more than Calculating weight (kg/km)

    Total

    Number of skeins x threads/diameter of a single thread

    (mm)

    CBW-20 CBWX-20

    1.5 1.57 408 12 x 34/0.07 1.97 11.70 12.6 14.8

    2.5 2.49 646 19 x 34/0.07 2.35 7.41 7.96 23.7

    4 4.03 513 19 x 27/0.10 3.08 4.58 4.79 38.3

    6. 3 6.27 798 19 x 42/0.10 3.73 2.94 3.07 59.6

    10 10.00 1273 19 x 67/0.10 4.73 1.85 1.93 95.1

    16 15.83 2016 12 x 7 x 24/0.10 7.18 1.15 1.21 150

    25 25.07 3192 19 x 7 x 24/0.10 8.55 0.736 0.769 238

    (35) 34.47 4389 19 x 7 x 33/0.10 9.90 0.535 0.559 328

    40 39.96 2261 19 x 7 x 17/0.15 11.03 0.462 0.483 380

    (50) 49.36 2793 19 x 7 x 21/0.15 12.15 0.374 0.391 470

    63 63.46 3591 19 x 7 x 27/0.15 13.50 0.291 0.304 604

    (70) 70.51 3990 19 x 7 x 30/0.15 14.18 0.252 0.274 671

    80 79.91 4522 19 x 7 x 34/0.15 15.08 0.231 0.241 760

    (95) 94.01 5320 19 x 7 x 40/0.15 16.43 0.195 0.205 894

    100 10.73 5700 19 x 7 x 25/0.15 18.27 0.183 0.191 958

    (120) 120.87 6840 19 x 7 x 30/0.15 20.24 0.153 0.160 1150

    125 127.59 7220 19 x 19 x 20/0.15 20.29 0.145 0.152 1214

    160 159.49 9025 19 x 19 x 25/0.15 21.75 0.116 0.121 1517

    (185) 185.00 10469 19 x 19 x 29/0.15 23.25 0.0997 0.104 1760

    200 196.15 11100 37 x 12 x 25/0.15 25.58 0.0940 0.0982 1866

    250 251.08 41208 37 x 12 x 32/0.15 28.57 0.0735 0.0768 2388

    315 310.58 17575 37 x 19 x 25/0.15 30.45 0.0594 0.0621 2954

    400 397.54 22496 37 x 19 x 32/0.15 34.13 0.0464 0.0485 3782

    500 496.92 28120 37 x 19 x 40/0.15 38.06 0.0371 0.0388 4727

  • 31

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Brailed Flexible Connector Pressed copper connectors, tin coated on request. Single wire diameter : 0.20 standard 0.10 on request

    Red copper Tinned copper

    Section (mm)

    A (mm)

    B (mm)

    S (mm)

    L (mm)

    Holes D Terminal Drill

    Current flow

    CRS 100 CSS 100 100 40 40 5 200 13 W1 480

    CRS 150 CSS 150 150 40 40 7 250 13 W1 590

    CRS 200 CSS 200 200 50 50 7 350 13 W1 760

    CRS 250 CSS 250 250 50 50 9 350 13 W1 910

    CRS 300 CSS 300 300 100 50 10 400 13 W2 950

    CRS 400 CSS 400 400 100 50 12 400 13 W2 1020

    CRS 500 CSS 500 500 100 50 16 400 13 W2 1300

    CRS 600 CSS 600 600 100 60 16 400 13 W2 1500

    CRS 800 CSS 800 800 80 80 16 400 13 W4 1700

    CRS 1000 CSS 1000 1000 100 100 17 450 13 W5 1900

    CRS 1200 CSS 1200 1200 120 120 17 450 13 W7 2150

    CRS 1500 CSS 1500 1500 On request

    CRS 2000 CSS 2000 2000

    Widths, lengths, cross-sections and bores are not included in table above, they are provided at request. An information concerning current flow is not binding, the values. Shown above are approximate values.

    Standard drillings

  • 32

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Flexible Insulated Bars Flexible insulated bars are made of high Flexibility laminated copper layers, coated with black coloured, selfextinguishable insulating PUV compound.

    Technical Characteristic Laminated Copper Strips Electrolytic copper annealed Cu ETP (state): 99.9% Cu.

    Resistivity : 1.78 cm2 / cm

    Vickers hardness : < 50 HV

    Maximum tensile strength > 200/MM2

    Elongation > 30%

    Dimensions (mm)

    Section (mm)

    Current-load Dimensions

    (mm) Section (mm)

    Current-load

    t 20C t 40C t 50C t 20C t 40C t 50C

    15.5 x 0.8 x 2 24.8 125 175 200 40 x 1 x 2 80 240 330 380

    15.5 x 0.8 x 3 37.2 160 210 240 40 x 1 x 3 120 330 450 540

    15.5 x 0.8 x 4 49.6 195 265 295 40 x 1 x 4 160 400 560 630

    15.5 x 0.8 x 6 74.4 225 320 360 40 x 1 x 5 200 450 630 710

    15.5 x 0.8 x 8 99.2 165 380 430 40 x 1 x 6 240 480 680 750

    15.5 x 0.8 x 10 124 300 420 480 40 x 1 x 8 320 600 830 920

    40 x 1 x 10 400 670 920 1030

    20 x 1 x 2 40 170 240 270

    20 x 1 x 3 60 230 320 360 50 x 1 x 3 150 400 570 650

    20 x 1 x 4 80 270 380 440 50 x 1 x 4 200 490 700 790

    20 x 1 x 5 100 300 430 490 50 x 1 x 5 250 540 780 880

    20 x 1 x 6 120 330 470 530 50 x 1 x 6 300 690 840 950

    20 x 1 x 8 160 400 560 620 50 x 1 x 8 400 680 1000 1130

    20 x 1 x 10 200 420 580 650 50 x 1 x 10 500 750 1100 1300

    24 x 1 x 2 48 200 280 320 63 x 1 x 5 315 650 900 1000

    24 x 1 x 3 72 250 360 410 63 x 1 x 6 378 690 950 1100

    24 x 1 x 4 96 280 410 460 63 x 1 x 8 504 840 1200 1350

    24 x 1 x 5 120 330 170 530 63 x 1 x 10 630 920 1300 1450

    24 x 1 x 6 144 360 510 570

    24 x 1 x 8 192 420 590 670 80 x 1 x 5 315 650 900 1000

    24 x 1 x 10 240 500 700 790 80 x 1 x 6 378 690 980 1100

    80 x 1 x 8 504 840 1200 1350

    32 x 1 x 2 64 230 320 360 80 x 1 x 10 630 920 1300 1450

    32 x 1 x 3 96 280 410 460

    32 x 1 x 4 126 320 460 520 100 x 1 x 5 500 860 1250 1400

    32 x 1 x 5 160 390 550 610 100 x 1 x 6 600 950 1380 1530

    32 x 1 x 6 192 440 620 700 100 x 1 x 8 800 1100 1580 1760

    32 x 1 x 5 256 510 720 800 100 x 1 x 10 1000 1220 1710 1920

    32 x 1 x 10 320 600 840 930 100 x 1 x 12 1200 1300 1800 2010

    32 x 1 x 10 320 600 840 930 100 x 1 x 12 1200 1300 1800 2010

  • 33

    LAMDA ELECTRIC

    Earthing and Lightning Protection

    PT. Lamda Teknologi Indonesia Komplek Ruko Taman Yasmin Sector VI No. 76 Jl. Ring Road Utara Taman Yasmin Bogor 16310 Telp/Fax : 0251-7155452 / 0251-8384529 Email : [email protected]

    Press Welded Flexible Connector

    Press welding can only be performed on red copper and it depends on its dimensions and customers specifications. The laminated sections are compressed and reconstructed by block during the terminal phase. via use of high currents. The contact resistance between each lamina is almost zero. Contact areas : PWR press welded. Copper strips : 0.1 mm thick witcover sheet 0.3 mm. It is also possible to deliver contact areas with tinned or silvered design.

    Red copper Section (mm)

    A (mm)

    B (mm)

    S (mm)

    L (mm)

    Holes D (mm)

    Terminal drill

    Current flow A

    PWR 200/180/40 200 50 40 5 180 13 W1 600

    PWR 200/230/40 200 50 40 5 230 13 W1 600

    PWR 320/230/40 320 50 43 8 230 13 W1 800

    PWR 400/230/40 400 50 45 10 230 13 W1 900

    PWR 250/250/50 250 60 45 5 250 13 W1 700

    PWR 400/250/50 400 60 48 8 250 13 W1 950

    PWR 500/250/50 500 60 50 10 250 13 W1 1100

    PWR 480/300/60 480 90 70 8 300 13 W2 1100

    PWR 600/300/60 600 90 70 10 300 13 W2 1200

    PWR 640/300/80 640 90 70 8 300 13 W4 1350

    PWR 800/300/100 800 90 70 10 300 13 W4 1500

    PWR 960/300/80 960 90 70 12 300 13 W4 1700

    PWR 800/350/100 800 110 80 8 350 13 W5 15550

    PWR 1000/350/100 1000 110 80 10 350 13 W5 1800

    PWR 1200/350/120 1200 110 80 12 350 13 W5 1900

    PWR 1200/400/120 1200 130 80 10 400 13 W7 2000

    PWR 1440/400/120 1440 130 80 12 400 13 W7 2200