    ECDIS ENC Check instruction for Chart Assistant program

    1. Prepare your ECDIS for conducting the checks as specified in the IHO Document ECDIS_check-Instructions_for_Mariners.pdf section 1.

    Please note that safety parameters can be changed on ECDIS Master station only

    therefore you should chose ECDIS Master for the set up and conducting the checks.

    2. Load the CD marked IHO ECDIS Check Dataset to the chosen station disk drive.

    3. Start Chart Assistant for Advanced user

    4. Press Update button

  • Page 2 of 8

    5. Select CD to install ENC Check data from the disk

    6. Confirm by pressing OK when it asks you if you would like to run the ENC installation disc.

    7. When this is done you will see a report of the last action made, click ok. Go to the Network panel of Chart Assistant and synchronize chart collections, then close Chart Assistant and run Navi-Sailor program.

  • Page 3 of 8

    Configuring ECDIS Chart Display for conducting the checks

    1. In the Charts panel of Navi-Sailor you will find the installed ENC charts. Point the cursor to AA5TDS05 in the chart list and click Load Chart button. The display will look like the following

  • Page 4 of 8

    2. Configure display as required by the IHO document ECDIS_check-Instructions_for_Mariners.pdf. this can be done in Layers and ENC tabs of Chart panel and in Monitoring panel of Navi-Sailor

    Note, that Safety Contour and Safety Depth parameters can be changed on Master station only

  • Page 5 of 8

    Transas ECDIS conformance to IHO standards

    According to IMO and IEC ECDIS standards, adequate software maintenance arrangements shall be

    supported by ECDIS manufacturer.

    Manufacturers shall provide customers with timely access, for example by website, to a list showing the

    IHO standards currently in effect for ECDIS, ECDIS application software versions, compliance status and

    regulatory approvals for the listed configurations/versions.

    To comply with the IMO/IEC requirements, Transas always trace changes in IHO Standards followed by

    implementing the changes in newer version of ECDIS. The Transas ECDIS: Navi-Sailor 3000 ECDIS-I and

    Navi-Sailor 4000 ECDIS MFD (Multifunction Display), fully comply with the following IHO standards:

    Implemented edition of the standards Current Edition in force

    NS 3000 ECDIS-I v. 4.00.10 (MNS27)

    NS 4000 ECDIS MFD v. 2.00.xxx (Starting from MNS28)

    ECDIS Performance Standard IMO resolution A817(19)

    ECDIS Performance Standard IMO resolution A817(19) and MSC232 (82)

    A817(19) and MSC232 (82)

    IEC 61174 ECDIS Methods of testing Edition 2.0 2001-10

    IEC 61174 ECDIS Methods of testing Edition 3.0 2008-09

    IEC 61174 ECDIS Method of testing Edition 3.0 2008-09

    Electronic Navigational Chart (ENC) IHO S-57 Edition 3.1.1

    Electronic Navigational Chart (ENC) IHO S-57 Edition 3.1.1 (3.1.2 starting from MNS30)

    S-57 Edition 3.1.1

    ECDIS Display and Presentation IHO S-52 PresLib Edition 3.4

    ECDIS Display and Presentation IHO S-52 PresLib Edition 3.4

    S-52 PresLib Edition 3.4

    ENC Data Protection IHO S-63 Edition 1.0

    ENC Data Protection IHO S-63 Edition 1.1

    S-63 Edition 1.1

    Raster Navigational Chart (RNC) S-61 Edition 1.0

    Raster Navigational Chart (RNC) S-61 Edition 1.0

    S-61 Edition 1.0

    Your ECDIS version number can be found at the License Info tab of the Config functional panel in

    Navi Sailor

    Information about conformance of different versions of Transas ECDIS is regularly updated and

    available at the web page http://www.transas.com/products/onboard/ns/ecdis/rules/default.asp

  • Page 6 of 8

    Transas ECDIS check issues

    Transas confirms that all latest versions of IHO standards have been implemented in new

    versions of Transas ECDIS (ref. above compliance table), there may still be discrepancies in

    displaying ENC Check dataset against the document ECDIS_check-Instructions_for_Mariners.

    Finding these discrepancies does not mean that your ECDIS does not comply with the relevant

    standards because they are caused by differences in interpretation of chart display rules.

    Details of the discrepancies with explanations are given below.

    1. ECDIS Check Instruction, Section 3 (the checks), Check 1, paragraph 5 says The New object symbol (4) should appear as a square and include the words Presentation Library 3.4 The text Presentation Library 3.4 is not displayed on the screen, while available by cursor pick report (ECDIS Info button). The text is not shown because it has been encoded in this particular ENC test data set in an unusual way, not normally used during normal ENC production.

    2. ECDIS Check Instruction, Section 3 (the checks), Check 3, paragraph 3. Symbol 4 is not displayed with isolated danger symbol in Standard Display mode. This is caused by different interpretation of the IHO presentation library that contains requirement to consider user setting Display isolated danger in shallow water and change content of Standard display according to this setting. The current version of Transas ECDIS has no such setting because this contradicts with IMO/IEC requirement to Standard display ECDIS shall present the Standard Display at any time by a single operator action

    If you have only found the two discrepancies listed above and have ECDIS version equal or

    newer than NS 3000 ECDIS-I v. 4.00.10 (MNS27) or NS 4000 ECDIS MFD v. 2.00.xxx (Starting

    from MNS28) we suggest you use the Info function for unknown chart objects and always

    switch on layer Isolated dangers in the tab Layers of Charts functional panel.

    To remove possible anomalies from Transas ECDIS and have more standardized chart

    presentation as expected by IHO experts, appropriate changes in the software were

    implemented and software patch for MFD ver. 2.00.320 (MNS32) was release in October 2011.

    After applying the latest patch to NS4000 ECDIS MFD, all chart symbols in the ENC check

    dataset are shown as expected by the IHO documentation.

  • Page 7 of 8

    More information about updating version of ECDIS software can be obtained from Transas

    Service Department ([email protected])

    The following table illustrates differences in displaying symbols before and after applying the

    MFD ECDIS software patch.

  • Transas Marine

    Registered in Sweden. Registration No. 556489-2866

    NS4000 ECDIS MFD MNS32 before applying the software patch

    (LAYERS: standard display, Isolated Dangers = OFF)

    NS4000 ECDIS MFD MNS32 after applying the software patch

    (LAYERS: Isolated Dangers = OFF, Isolated Dangers in shallow water

    = ON, Names = ON)