58
Echo in the ITU Dr Caroline Daly Cardiologist, SJH

Echo in the ITU

  • Upload
    hanne

  • View
    46

  • Download
    5

Embed Size (px)

DESCRIPTION

Echo in the ITU. Dr Caroline Daly Cardiologist, SJH. Scope of uses of ECHO in ICU. Following cardiac surgery Diagnosis Monitoring. Advantages. Cheap Portable Widely available Non invasive, no toxic contrast, no radiation. Rationale for use of Echo in ITU. - PowerPoint PPT Presentation

Citation preview

Page 1: Echo in the ITU

Echo in the ITU

Dr Caroline DalyCardiologist, SJH

Page 2: Echo in the ITU

Scope of uses of ECHO in ICU

• Following cardiac surgery

• Diagnosis

• Monitoring

Page 3: Echo in the ITU

Advantages

• Cheap

• Portable

• Widely available

• Non invasive, no toxic contrast, no radiation

Page 4: Echo in the ITU

Rationale for use of Echo in ITU

• Point-of care echocardiography in the management of the critically ill patient

• Provides rapid assessment of cardiac function and physiology

• Complements data available from standard invasive hemodynamic monitoring

• Both a diagnostic and monitoring tool for rapid bedside assessment of cardiovascular pathophysiology in the critically ill

Page 5: Echo in the ITU

Key Questions in ITU

• Systolic function and RWMA• tamponade and pericardial effusion• hypovolemia and volume responsiveness• acute cor pulmonale• hypoxemia• complication of AMI• chest trauma• assessment of shock

Page 6: Echo in the ITU

Disadvantages of TTE in ITU

• Poor ECHO images in:

• Obese• COAD/hyperinflated chest• Chest wall deformity• Oedema• Post cardiac surgery –wounds, pain, drains

Page 7: Echo in the ITU

TOE

• Invasive - but minimally invasive vs other Ix• Overcomes the issues of poor image quality• Better spatial resolution & better views of posterior structures• More sensitive for detection of endocarditis - >90 % vs 68% • Complications (retrospective series n= 7200 pts in cardiac

surgery : Kallmeyer et al.)– severe odynophagia (0.1%)– dental injury (0.03%)– endotracheal tube malpositioning (0.03%)– upper gastrointestinal hemorrhage (0.03%)– oesophageal perforation (0.01%)

Page 8: Echo in the ITU

Emergency Echo

• FEEL: focused echocardiography evaluation in life support

• FATE: focused assessed transthoracic echo

Goals• acquire standard TTE views in ACLS compliant

manner• recognise major causes of arrest/ shock• recognise when referral for second opinion

Page 9: Echo in the ITU

FATE - interpretation

• Look for obvious pathology– Masses, vegetations, intra thoracic foreign bodies

• Assess morphology/dimensions

• Assess myocardial function• Assess valves• Image pleura on both side• Relate the information to the clinical context

Page 10: Echo in the ITU

Normal FATE view

• Subcostal 4 chamber• Apical 4 chamber• Parasternal long axis• Parasternal LV short axis• Pleural scanning

Page 11: Echo in the ITU

Extended FATE

• Normal FATE +• Subcostal vena cava• Apical 2 chamber• Apical long axis• Apical 5 chamber• Parasternal short axis mitral plane• Parasternal aorta short axis

Page 12: Echo in the ITU

FATE

• Hypovolemia• Myocardial dysfunction• Pericardial effusion• Pulmonary embolism• Papillary muscle rupture• VSD in AMI• Severe valve dysfunction• Pleural effusion/ pneumothorax

Page 13: Echo in the ITU

Key morphological parameters

• LV shape / chamber dimension / thickness• RV shape / chamber dimension / thickness• Atrial dimension• IV septum position

Page 14: Echo in the ITU

Pathologies to be considered

• Pericardial effusionpost cardiac surgery, post cardiac catheterization, trauma, renal failure, infection

• Dilated RA + RVpulmonary embolism, RV infarction, pulmonaryhypertension, volume overload

• Dilated LA + LVischemic heart disease, dilated cardiomyopathy,sepsis, volume overload, aortic insufficiency

Page 15: Echo in the ITU

Pathologies to be considered Ctd

• LV hypertrophy

Aortic stenosis, arterial hypertension, left ventricular outflow tract obstruction ( eg SAM or sub-aortic membrane), hypertrophic cardiomyopathy, myocardial deposition (amyloid, haemochromatosis)

Page 16: Echo in the ITU

Pre-existing cardiac disease?

• RV dilatation = acute or chronic• LV dilatation = almost always chronic• Biventricular dilatation = chronic failure• Atrial dilatation = chronic pressure or volume

overload• RV or LV hypertrophy = chronic pressure

overload

Page 17: Echo in the ITU

Severe hypovolaemia

• End systolic LV obliteration (kissing walls)

• LV end diastolic area (LVEDA) < 5.5 cm/m2 BSA• (or < 10 cm2)

• LVEDA variation with loading

Page 18: Echo in the ITU

Severe Hypovolaemia

• IVC diameter– spontaneous respiration: EED < 9 mm– mechanical ventilation: EED < 15 mm

• IVC respiratory variation– spontaneous respiration: > 50%– mechanical ventilation: > 18%

• IVC variation with loading

EED = End expiratory dimension

Page 19: Echo in the ITU

Volume Overload

• Dilated, fixed IVC

Pitfalls• cardiac tamponade• constrictive pericarditis

Page 20: Echo in the ITU

Basic Volume Status Assessment

• Easy in severe hypovolaemia• Easy in clear volume overload• Difficult in less severe hypovolemia/significant

cardiac disease

• Consider pre-existing cardiac disease• Consider respiratory status

Page 21: Echo in the ITU

Ventricular Function assessment

• LV global systolic function– fractional shortening (FS)– FS% = (LVEDD-LVESD)/LVEDD x 100%– With RWMA is unreliable, but, simplified Teicholz

method EF % = FS % x 2– visual ejection fraction (eyeballing)– Simpsons (planimetry of LV cavity)

• LV regional function• RV systolic function

Page 22: Echo in the ITU

Qualitative Assessment of Function

• Qualitative assessment of LV function– tend to be underestimated in a dilated LV– overestimated in small cavity LV

• Interpret findings in the context of drugs and preload (volume status)

• Repeated echo assessment of LV function• Interpret findings considering inotropic/

mechanical support• Marked tachycardia/atrial fibrillation may

underestimate of LV systolic function

Page 23: Echo in the ITU

RV function

• RVEDA / LVEDA• > 0.6 moderate dysfunction• > 1 severe dysfunction

• Paradoxical septal movement

Page 24: Echo in the ITU

Mitral Valve

• Excessive leaflet mobility– myxomatous valve disease, – torn chordae, – prolapse,– Flail– myocardial infarction, torn papillary muscle

• Restrictive leaflet mobility– rheumatic disease– calcific disease– dilated cardiomyopathy– acute ischemic disease

Page 25: Echo in the ITU
Page 26: Echo in the ITU
Page 27: Echo in the ITU
Page 28: Echo in the ITU

Focused Echo -

• Focused echocardiography as an adjunct in the peri-arrest period is likely to become a core competency for acute medicine trainees

• World Interactive Network Focused on Critical Ultrasound = “Winfocus” basic echo

• “Echocardiography practice, training and accreditation in the intensive care”

http://www.cardiovascularultrasound.com/content/6/1/49

Page 29: Echo in the ITU

FEEL: focused echocardiography evaluation in life support

• To assess the function of the heart and identify treatable conditions in peri-resuscitation care

• Differentiates"true" PEA from "pseudo-PEA"• Identify 4 treatable causes of cardiac arrest– cardiac tamponade– hypovolemia– pulmonary embolism– severe LV dysfunction

Page 31: Echo in the ITU

RV

• Small and hyperkinetic RV: tamponade

• Dilated and hypokinetic RV: RV failure– LV dysfunction– RV AMI– Acute pulmonary embolism

Page 32: Echo in the ITU

LV• Severe LV hypokinesia– LV AMI, – Sepsis related– Myocarditis– DCM

• LV hyperkinesia– Acute valvular dysfunction (AR, MR), – HOCM,– diastolic dysfunction

Page 33: Echo in the ITU

Bibliography

• ICU echocardiography- should we use it in a heartbeat? Chest 2002

• Portable echocardiography- is essential for the treatment of acutely ill patients BMJ 2006

• Echocardiography for the intensivists Care of the Critically Ill 2003

• Beside Ultrasonography in the ICU Chest 2005• Echo in ICU- time for widespread use ICM 2006

Page 34: Echo in the ITU

Advanced Critical Care Echo

• Evaluating LV systolic function• Evaluating RV function • Monitoring Cardiac Output• Fluid Responsiveness– IVC and LV

• Diastolic function• RV function• Tamponade

Page 35: Echo in the ITU

Cardiac Output

• Cardiac output = Stroke volume x Heart Rate

• Stroke Volume

Calculated from (i) Pulse Wave VTI and CSA of– LVOT – RVOT – Mitral inflow (at annulus)

• (ii) Simpson’s (EDV - ESV = SV).– (May be overestimated if RWMAs)

Page 36: Echo in the ITU

CO by TOE in liver transplantation

Curr Cardiol Rev. 2011 August; 7(3): 184–196.

Page 37: Echo in the ITU

Continuous monitoring of CO (TOE)• Meta-analysis of comparison of 2 available

ultrasonographic devices- CO evaluation from pulsed-wave Doppler of the descending aorta. (CardioQ and HemoSonic 100) v thermodilution via PA

• Left ventricular stroke volume estimated by mean systolic velocity measurement using a nomogram in the CardioQ, and an M-mode echocardiography estimate of aortic diameter using HemoSonic 100.

• 21 studies, 314 patients, 2400 paired measurements. • Reasonable correlation was found between both

methods, with a mean difference of -0.69 to 2.00 l/min.• Is good to track changes

Page 38: Echo in the ITU

Haemodynamics in ITU

Page 39: Echo in the ITU
Page 40: Echo in the ITU

Fluid ResponsivenessIVC• IVC size correlated to CVP/RAP spontaneous breathing• In controlled ventilation IVC will expand in inspiration (as

venous return is reduced) and reduce in expiration (opposite of spont).

• Absence of respiratory variation : 90% chance will not be fluid responsive.>11% variation identifies responders

IVC collapsibility index = max diameter - minimum diameter / mean diameter

x100 to get percentage

Page 41: Echo in the ITU

LV : fluid responsiveness

• LVVariation in LV stroke area with respiration shown to predict fluid responsiveness (change >16%).

• ie area of LV in PSAX papillary level in systole and diastole and subtract systole from diastole - see how this changes with respiration

• Impractical/time consuming without appropriate software in machine.

Page 42: Echo in the ITU

LVOT : fluid responsiveness

• LVOTVmax or VTI variation with respiration of >12% predicts fluid responsiveness

• (max - min / mean) x 100

VTI increase of >12% 1min after PLR predicts fluid responsiveness

Page 43: Echo in the ITU

Diastolic Dysfunction

• Important cause of cardiogenic pulmonary oedema and failure to wean even with reasonable systolic function.– IHD – Hypertension – AS – Cardiomyopathy – Sepsis (sepsis induced cardiomyopathy) – Inotropes (adrenaline). PDE inhibitors (lusitropes)

preserve diastolic function better.

Page 44: Echo in the ITU

Diastolic dysfunction• LV compliance reduced so LVED Pressure Volume

relationship shifted up and left so:

• LV can be under-filled despite high filling pressures. • Optimum filling range narrow (under or over filled

easily)

• Therefore a hypovolaemic LV with diastolic dysfunction will have elevated filling pressures, may respond well to fluid, but will easily be overloaded with pulmonary oedema resulting.

Page 45: Echo in the ITU

Causes of RV dysfunction

• RV volume overload. • RV pressure overload (ARDS, PE). • Myocardial contusion (most anterior cardiac chamber). • Myocardial ischaemia. • RCA air embolus post cardiac surgery.

• All forms of RV overload compromise LV diastolic function.

Page 46: Echo in the ITU

RV Volume Overload

• RV very compliant so volume can increase with little change in pressure.

• If severe volume increase will move over top of Starling curve and start to fail.

• TR will also develop.– Acute from IV fluid or renal failure.– Chronic from ASD, VSD, severe TR or PR.

• Chronic volume overload can cause RV hypertrophy and pressure overload.

• In pure volume overload the RV will not be hypertrophied

Page 47: Echo in the ITU

RV Pressure Overload• RV very sensitive to increase in afterload and will quickly result

in dilatation and failure if acute (eg PE or ARDS).• If chronic RV will be hypertrophied, will tolerate increased

afterload better.•

Features of pressure overload• Dilated RV. Hypertrophied if chronic.• Acute pressure overload (PE or ARDS) will look the same as

volume overload with septal flattening in diastole.• If chronic from PHT(recurrent PE, L sided regurg, L heart failure,

COPD) RV will be hypertrophied and able to generate very high pressures (>50mmHg). The septum is D shaped in systole (paradoxical motion) going back to normal in diastole.

Page 48: Echo in the ITU

Tamponade

2D and M-mode.

Look for chamber collapse in diastole.

RA then RVOT then whole RV then LA then LV.

RAP will be high so IVC dilated with little or no respiratory variation.

Page 49: Echo in the ITU

Tamponade

• Pulse Wave Doppler• Assess RV and LV inflow in A4C. • Inspiration increases flow of blood into R heart (sucks it

in) and reduced flow into L heart (pulm vessels expand). • This is exaggerated in tamponade (pulsus paradoxus). • This is the opposite if positive pressure ventilation• Measure max and min E wave velocities for each valve.• Assess outflow of RVOT and LVOT by measuring Vmax

and/or VTI.

Page 50: Echo in the ITU

Tamponade physiology

Page 51: Echo in the ITU
Page 52: Echo in the ITU
Page 54: Echo in the ITU
Page 56: Echo in the ITU
Page 57: Echo in the ITU
Page 58: Echo in the ITU

Ultrasound in cardiac arrest due to pneumothorax.

Typically, cardiac chambers are small and hyperkinetic (a), inferior vena cava is dilated (b)