FAU-TDL
W W W . E C O T E C C O . C O M
FAU-TDL Laser TechnologyNow Available
The FAU-TDL uses Tunable Diode Laser Technology to enable accurate andreliable measurements with no drift over time or cross gas sensitivity.
This analyzer is the most reliable and cost effective solution forCarbon Credit verification and Green House Gas (GHG) reporting.
Tunable Diode Laser Technology
No drift over time/No cross gas contamination
Annual Factory Calibration Not Required
FIELD ANALYTICAL UNITTUNABLE DIODE LASER
Features• Tunable Diode Laser Technology• Measures % CH4, CO2 & O2
wavelength (CH4 & CO2)• Accuracy of 1.0% full scale (CH4, CO2 & O2)• No drift overtime (CH4 & CO2)• Optically isolated analog outputs - 4-20mA
• Options: Rack mounted or NEMA 4x enclosure• Optional: Gas Conditioning unit-with e�ciency of 99.97% removal of (0.3-06 micron particles)• Optional: Temperature Probe
• Accurate & reliable measurements• No cross gas contamination• Fixed position continuous analyzer• Continuous readings with rapid response• Integrates to AEMS or existing SCADA Systems• Low cost of ownership
• Green House Gas/Carbon Credit Projects (CDM, CAR, CCX, REGGI, GSV2, VCS)• Gas to energy projects• Environmental compliance projects• Closed site monitoring
Applications
Technical Specification
ECOTEC SOLUTIONS, INC.850 South Via Lata, Suite 112
Colton, CA 92324 Phone +1 (909) 906-1001
© ECOTEC SOLUTIONS, INC. 2015 #CTS-FAUTDL Rev 8-2016
www.ecotecco.com
FAU-TDLFIELD ANALYTICAL UNITTUNABLE DIODE LASER
Power SupplyPower Requirements
90-240 VAC, 50-60 Hz 1.4A
Gas RangesGases Measured CH4
CO2
By Tunable Diode Laser
O2 By internal electrochemical cell
0-100% 0-25%
0-100% Ranges
Gas Accuracy
By Tunable Diode Laser
CH4CO2O2
± 1.0%± 1.0%
± 1.0%CH4CO2O2
Gas ConditioningCan sample on wet or dry basis:gas must be non-condensing
Particles > 20 micronsParticle removal
Response Time, T90
Liquid removal
PumpFlow Rate 200-1000 ml/minVacuum / Pressure -120” W.C. Max /
+4 PSI Max
Environmental ConditionsAmbient TemperatureRange Relative Humidity
-4°F to 158oF (-20°C to +70oC)
0-95% non condensing
Optional AccessoriesTemperature Probe ±1oC of reading -22oF to 266oF
(-30oC to +130oC)
Physical
19” Rack MountDimentions and Weight7”H x 19”W x 18”D (178mm x 483mm x 457mm) - 31 lbs (14kg)
NEMA 4x enclosure 25.4”H x 17.1”W x 9.8”D (645mm x 434mm x 249mm)
The development of ECOTEC’s FAU-TDL is the culmination of research by NASA’s Jet Propulsion Laboratory for use on Mars. The optical
This technique produces an analyzer with a fast response speed, where the laser light stimulates vibrations and rotation in the molecule, resulting in energy absorption and enabling the sensing of gas.