www.baumerprocess.com Data Sheet A 11 D6.181
Design and specifications subject to change without notice Page 1
ED 701 – Hygenic Pressure Transmitter
Hygienic process connections
Complete range of electrical connections
4 ... 20 mA and Voltage outputs
Accuracy: 0.1%, 0.2% and 0.4% FS
Quick response time < 25 ms (Option 5 ms)
High long-term stability
Excellent repeatability
Active compensation for temperature drifts
ATEX II 1G, II 2G, II 1/2G and II 1D
Lloyd‘s Register Approval
Compatibility with CIP/SIP
Description
The large choice of pressure and electrical connections makesthe ED 701 series suitable for a large variety of applications. TheED 701 pressure transmitters are available in 4… 20 mA currentloop or in voltage output signal versions. This transmitters offer avery high accuracy over a wide temperature range, an excellentrepeatability and long time stability as well as a short responsetime (down to 5 ms).
The piezo-resistive silicon sensor is anodic bonded on avery stable glass base, which is attached to a stainless steelconstruction. This assembly guarantees an excellent thermalisolation.
The sensor is isolated from the process by a stainless steeldiaphragm (1.4435 / 316L) and a filling liquid. The electronics islocated within the hermetically sealed transmitter housing whichgives the ED 701 an excellent resistance to humidity, shock andvibration. Protection class, from IP 65 to IP 67 only depends onthe choice of the electrical connection.
The electronics is a state-of-the-art signal processing unitfitted with a fast micro-controller allowing the compensation ofdrift effects due to temperature on the sensor signal, over a widetemperature range with a fast response time.
The ED 701 is available with a great variety of pressure andelectrical connections to meet all requirements. The electricalconnection can be replaced easily and gives access to theAutozero adjustment.
The hygienic design of the ED 701 series is particularlydedicated to the food and beverage processing industry, thepharma and the biotechnology industry. According to its ATEXapproval the ED 701 can be used in potentially explosiveatmospheres (gases, vapors and dust). The ED 701 has gotthe Lloyd‘s Register approval, which makes it the ideal productfor environments such as in the marine, offshore and industrialapplications.
ED701 for general industry applications: refer to datasheet ED701_Industrial (D6.180, ED701 – General Industry Transmitter)
www.baumerprocess.com DataSheet A11 D6.181
Designandspecificationssubjecttochangewithoutnotice Page2
1)PressureconnectionL,Z,N/9412,N/9413,Y/9451andY/9452:Notavailableforpressureranges<400mbar.Availableonlywithanaccuracyof0.4%(OrderingcodePosition5)forpressureranges<1bar.Availablewitheveryaccuracycodesforpressureranges1bar.
2)PressureconnectionZ,Y/9451,8and9:Onlyavailablewithoutcoolingneck.TheaccuracycodesAandBarethennotavailable(OrderingcodePosition5).
3)PressureconnectionW:OnlyavailablewiththeaccuracycodesAundB(OrderingcodePosition5),becauseacoolingneckisalwaysintegrated.Onlyavailableforpressureranges10bar.
4)Pressureconnection8and9:Theseconnectionshaven’tgotanydiaphragm.Theyarethenonlyavailablewithoutanyoilfilling(Code9oftheorderingcodePosition11).
5)Lloyd‘sRegisterapprovedED701haveareducedsupplyvoltagerangeandtheambianttemperatureislimiteddependingonthemediumtemperature.ChecktheLloyd‘sRegisterparagraph.
6)FieldHousing:Thecableglandarecompatiblewithcablediameterof5mmto12mm.
7)AccuracycodeAandB(hightemperature):Ifnocalibrationtemperatureisspecified(Option9007/TTTT),thecompensatedtemperaturerangeis[–10°..+80°C].Themaximummediumtemperatureisdependingontheambienttemperature(Tamb):IfTamb40°Cthemax.allowedmediumtemperatureis300°C.IfTamb60°Cthemax.allowedmediumtemperatureis200°C.IfTamb80°Cthemax.allowedmediumtemperatureis150°C.Themax.mediumtemperaturemustnevergoover+200°C,whentheoilfillingistheFDAapprovedwhiteoil.
8)AccuracycodeA:Fortemperatureabove200°ConlythepressureconnectionsJandWwithsiliconorhalocarbonoilareavailable(OrderingcodePosition11).
9)ATEXcertificationisonlyavailablewith4...20mAoutputsignal
Ordering details
Orderingcodedigit:Positions 1 2 3 4 5 6 7 8 9 10 11 12
Process connectionMalethreadG1”flushdiaphragmcone J MalethreadG1”flushdiaphragmO’ring K MalethreadG1⁄2”flushdia.DIN3852(CombiConnect)1) L MalethreadG1⁄2”flushdiaphragmO’ring1)2) ZMalethreadG1⁄2”flushdiaphragmcone3) WAsepticClampDIN11864-3(Additionalcodeneeded) FClampDIN32676(Additionalcodeneeded) HNeumoBioConnect®asepticconnection(Additionalcodeneeded) I ClampISO2852(Additionalcodeneeded)1) NTri-Clamp®,sanitaryclampconnection(Additionalcodeneeded)1)2) YMalethreadG1⁄2”EN837-1forassemblywithpressureseal2)4) 8 MalethreadG1⁄4”EN837-1forassemblywithpressureseal2)4) 9Specificprocessconnection(Additionalcodeneeded) 0
Output signal4...20mA 2 0...10VDC 4 0...5VDC 5
ApprovalCEconform 0ATEX9) 1Lloyd‘sRegister5) 3Lloyd‘sRegister5)+ATEX9) 4
Electrical connection2metershieldedcable3conductors,IP65 12metershieldedcable3conductors,IP67 9 FischerPlug,IP67 2DIN41524BinderPlug,IP65 3 DIN43650Plug,IP65 4 Bendix6polePlug,IP65 5 M12,4poleIndustrialPlug,IP67 6 1⁄2”NPT,cablelength1m,IP67 7 FieldHousing,cableglandbrassnickel-plated,IP676) AFieldHousing,cableglandstainlesssteel,IP676) BFieldHousingcableglandPA,IP676) CFieldHousingM12Plug,stainlesssteel,IP67 D
AccuracyMedium temperature up to 125°C0.4%FS,compensatedtemperaturerange–10°…+125°C 10.2%FS,compensatedtemperaturerange–10°…+125°C 20.1%FS,compensatedtemperaturerange–10°…+80°C 35 ms response time0.4%FS,5ms,compensatedtemperaturerange–10°…+80°C 60.2%FS,5ms,compensatedtemperaturerange0°…+60°C 7High medium temperature0.4%FS,integratedcoolingneck(uptomax.300°C)7)8) A0.2%FS,integratedcoolingneck(uptomax.200°C)7) B
Pressure unit Gaugepressure(100mbarupto40bar) 3Absolutepressure(400mbarupto40bar) 4Negativegaugepressure(0…-100mbar,-1…40bar) 5
Pressure range 100mbarupto40bar:gaugepressure 400mbarupto40bar:absolutepressure
SeetablePressurerange
www.baumerprocess.com DataSheet A11 D6.181
Designandspecificationssubjecttochangewithoutnotice Page3
Ordering details (continued)
Orderingcodedigit:Positions 1 2 3 4 5 6 7 8 9 10 11 12
Wetted parts Allstainlesssteel 1AllHastelloyC 2Allstainlesssteel,withelectropolishedpressureconnection(Ra0.8) 8Strengthenedstainlesssteeldiaphragm10) 3Stainlesssteel,goldplated10) 9
Oil fillingFDAapprovedwhiteoil(Standard)11) 1Siliconoil11) 0Halocarbonoil11) 2Nooilfilling12) 9
10)Strengtheneddiaphragmandgoldplated:Ifnocalibrationtemperatureisspecified(Option9007/TTTT),thecompensatedtemperaturerangeis-10°…+80°C.OnlyavailablewiththepressureconnectionsJ,K,N/9414,N/9416,N/9418.Onlyavailablefortheaccuracyclasses0.2%und0.4%(OrderingcodePosition5).Onlyavailableforpressureranges1bar.
11)Operatingtemperature:refertothetechnicaldata.12)Nooilfilling:onlyforassemblywithpressureseal.
Thefollowingorderingcodeshavetobecompletedwithanadditionalcodetobepreciselydefined:
Process connection Code F (Ordering code Position 1) – Aseptic clamp DIN 11864-3Thefollowingadditionalcodesareavailable.Othersonrequest: /9390 Clampconnectionwithexternaldiameter50.5mm,BKS,SeriesA,FormA,NominaldiameterDN25DIN. PipeaccordingtoDIN11866-A. /9391 Clampconnectionwithexternaldiameter50.5mm,BKS,SeriesB,FormA,NominaldiameterDN33.7ISO. PipeaccordingtoDIN11866-B Example:ED701Fxx.xxx.xxx.xx/9391
Process connection Code H (Ordering code Position 1) – Clamp DIN 32676 Thefollowingadditionalcodesareavailable.Othersonrequest: /9533 Clampconnection,externaldiameter50.5mm,,NominaldiameterDN25,DN32andDN40. PipeaccordingtoDIN11850 Example:ED701Hxx.xxx.xxx.xx/9533
Process connection Code I (Ordering code Position 1) – Neumo BioConnect® aseptic connectionThefollowingadditionalcodesareavailable.Othersonrequest: /9402 FlangeformV,NominalDimension48.3.Flangeexternaldiameter100mm.PipeaccordingtoDIN11866-B, DINENISO1127 Example:ED701Ixx.xxx.xxx.xx/9402
Process connection Code N (Ordering code Position 1) – Clamp ISO 2852 Thefollowingadditionalcodesareavailable.Othersonrequest: /9412 Clampconnection,externaldiameter34mm,NominalDimensionDN21.3.PipeaccordingtoISO2037 /9413 Clampconnection,externaldiameter50.5mm,NominalDimensionDN25.PipeaccordingtoISO2037 /9414 Clampconnection,externaldiameter50.5mm,NominalDimensionDN33.7andDN38. PipeaccordingtoISO2037 /9416 Clampconnection,externaldiameter64mm,NominalDimensionDN40andDN51.PipeaccordingtoISO2037 /9418 Clampconnection,externaldiameter77.5mm,NominalDimensionDN63.5.PipeaccordingtoISO2037 Example:ED701Nxx.xxx.xxx.xx/9414
Process connection Code Y (Ordering code Position 1) – Tri-Clamp®, sanitary clamp connection Thefollowingadditionalcodesareavailable.Othersonrequest: /9451 Tri-Clamp®3/4“connection,externaldiameter24.9mm. /9452 Tri-Clamp®1“connection,externaldiameter50.4mm. /9453 Tri-Clamp®11/2“connection,externaldiameter50.4mm. /9454 Tri-Clamp®2“connection,externaldiameter63.9mm. Example:ED701Yxx.xxx.xxx.xx/9451
Process connection Code 0 (Ordering code Position 1) – Specific pressure connection Thefollowingadditionalcodesareavailable.Othersonrequest: /9483 BBS-Systems®,Quick-Connectasepticclampwithnotch,ISODN25,Externalclampdiameter50.5mm /9486 Malethread1“-11.5NPT,flushdiaphragm Example:ED7010xx.xxx.xxx.xx/9483
Additional ordering codes
www.baumerprocess.com DataSheet A11 D6.181
Designandspecificationssubjecttochangewithoutnotice Page4
Standard ED 701 – Delivery
Calibration temperature:TheED701arecalibratedat+25°C.Ifanothercalibrationtemperatureisneeded,theoption/9007/TTTThastobementioned,aspartoftheorderingcode(seeOptions).Electrical connections:Nocablesocketwillbeprovided.Suchaccessorieshavetobeorderedseparately(seeAccessories).Test Certificate:EachED701willbedeliveredwithaTestCertificateatthecalibrationtemperature(6points).Ifnotspecified,theCertificatewillbeinGerman(seeOptions).O-Ring seals:ThepressureconnectionsJ,K,L,ZandW(OrderingcodePosition1)arealwaysdeliveredwithaNBRO-Ring.OtherO-Ringsareavailable(seeAccessories).AlltheO-RingsareapprovedbytheFDA.TheED701withpressureconnectionF,I,N,Yand0aredeliveredwithoutanyseals.
126 0...100B06 0...150136 0...160A56 0...200146 0...250B26 0...300B36 0...350156 0...400A66 0...500166 0...600B46 0...700176 0...1000P46 0...1250B56 0...1400186 0...1600D06 0…–10020)D16 0…–16020)D26 0…–20020)
L25 1...10015 0...0.6025 0...1035 0...1.6A15 0...2045 0...2.5L35 0...2.8055 0...4A25 0...5065 0...6L45 0...7L05 0...8075 0…10L15 0…12085 0…16A35 0…20095 0…25
Code Range Code Range Code Range Code Range mbar mbar bar bar
L55 0...30105 0...40D85 0…–120)E05 –0.1…120)E15 –0.1…220)315 –1…020)H05 –1…120)525 –1…320)535 –1…520)545 –1…920)E65 –1…1.620)F05 –1…220)F15 –1…1020)F45 –1…12.520)F25 –1…2020)F35 –1…2420)F65 –1…4020)
D46 0…–40020)D56 0…–50020)D66 0…–60020)A76 0...2000196 0...2500206 0...4000A86 0...5000216 0...6000P76 0...7300226 0...10000P86 0...18300H66 –100…10020)H76 –200…20020)H86 –500…50020)C46 –200…020)C56 –500…020)
Description Ordering code
Specific pressure range: /SETRAnapplicationspecificpressurerangecanbedefinedhere.Therangemustbegiveninplaintext.Thesmallestavailablepressurerangesare100mbar(gaugeandnegativegaugepressure)and400mbar(absolutepressure).Example:/SETR500mbar…2500mbarSpecific calibration temperature (temperature of the medium): /9007/TTTTExample:/9007/0100.TheED701willbecalibratedforamediumtemperatureof100°C(exfactory).Thisoptionisreducingthecompensatedtemperaturerangeto±25°Caroundthespecifiedcalibrationtemperature.Ferrite content according to customer specifications /9330Ferritecontentofthepiecesincontactwiththefluidaccordingtocustomerspecifications.Example:/9330/Pressureconnection<1%,weld<3%.Free of oil and grease /9331Freeofoilandgrease(piecesincontactwiththefluid).TheED701iscleanedandpackedaccordingly.Pressure connection electropolished according to customer specifications /9344Thepressureconnectioniselectropolishedaccordingtocustomerspecifications.Onlyavailablewithcode8attheposition10oftheorderingcode.Example:/9344/Ra0.4.Language of the Test Certificate and Operating Manual:BothdocumentsareavailableinGerman,FrenchandEnglish.Thedesiredlanguagemustbespecifiedinplaintextwiththeorderingcode.StandardwillbeGerman.
Options
Pressure range
20)Negativegaugepressureranges:onlyavailablewiththepressureunitcode5(OrderingcodePosition6).
www.baumerprocess.com DataSheet A11 D6.181
Designandspecificationssubjecttochangewithoutnotice Page5
Code Range Code Range Code Range psi psi in H2O [4°C]
20)Negativegaugepressureranges:onlyavailablewiththepressureunitcode5(OrderingcodePosition6).
17G 0...4018G 0...5019G 0...6022G 0...10030G 0...30040G 0...750
Code Range Code Range Code Range Code Range mm H2O [4°C] m H2O [4°C] m H2O [4°C] m H2O [4°C]
177 0...1000P47 0...1250187 0...1600A77 0...2000197 0...2500207 0...4000A87 0...5000217 0...6000P77 0...7300227 0...10000P87 0...18300
028 0...1038 0...1.6A18 0...2048 0...2.5L38 0...2.8058 0...4A28 0...5068 0...6L48 0...7L08 0...8078 0...10L28 1...10L18 0...12088 0...16A38 0...20098 0...25
H08 -1...120)H18 -2...220)H28 -5...520)H38 -10...1020)C08 -2...020)C18 -5...020)D88 0...-120)E08 -0.1...120)E18 -0.1...220)E68 -1...1.620)F08 -1...220)F18 -1...1020)F28 -1...2020)F38 -1...2420)F48 -1...12.520)
17D 0…30018D 0…40032D 0…50070D –1.5…1.520)71D –3…320)72D –6…620)80D –15…1520)60D –1.5…020)61D –3…020)62D –6…020)81D –15…3020)82D –15…6020)83D –15…15020)
L58 0...30L78 0...32108 0...40A48 0...50118 0...60L88 0...64L68 0...70128 0...100L98 0...128B08 0...150138 0...160A58 0...200148 0...250B28 0...300B38 0...350158 0...400
Code Range Code Range Code Range Code Range MPa KPa KPa KPa
013 0...0.6023 0...1033 0...1.6A13 0...2043 0...2.5053 0...4883 -0.1...0.920)E03 -0.1...120)E13 -0.1...220)
072 0...10L22 1...10L12 0...12082 0...16A32 0...20092 0...25L52 0...30L72 0...32102 0...40A42 0...50112 0...60L82 0...64L62 0...70122 0...100132 0...160A52 0...200142 0...250B22 0...300B32 0...350152 0...400
392 -60...020)402 -100...020)C92 0...-6020)D02 0...-10020)642 -10...1520)652 -15...1020)662 -15...2520)672 -25...1520)682 -20...4020)692 -40...2020)702 -40...6020)712 -60...4020)722 -60...10020)732 -100...6020)742 -100...15020)G02 -100...20020)922 -100...30020)932 -100...50020)
A62 0...500162 0...600B42 0...700172 0...1000P42 0...1250B52 0...1400182 0...1600A72 0...2000192 0...2500202 0...4000H32 -10...1020)H42 -20...2020)H52 -50...5020)H62 -100...10020)352 -10...020)362 -16...020)C22 -20...020)372 -25...020)382 -44...020)C32 -50...020)
05D 0...1.506D 0...2.507D 0...308D 0...409D 0...645D 0...7.510D 0...1011D 0...1512D 0…3013D 0…6051D 0…7514D 0...10015D 0...15016D 0…200
Pressure range
www.baumerprocess.com DataSheet A11 D6.181
Designandspecificationssubjecttochangewithoutnotice Page6
Technical data
Measurement characteristics
Pressure rangeGaugepressure: from0…100mbarupto0…40bar.Absolutepressure: from0…400mbarupto0…40bar.Thestandardpressurerangesarelistedinthepressurerangetable.OtherspecificrangesareavailablewiththeoptionSETR.
Over pressure limit Pmax.Depending on the pressure range 0.. PP [bar] 0,1..0,35 0,4..1,0 1,6..5 6..20 25 30..40Maximum pressure Pmax [bar] 1 3 15 60 70 135
Accuracy0.1%FS,0.2%FSund0.4%FSclasses(seeorderingcodePosition5).Hysteresis and repeatability ±0.05%FS
Long term stability ±0.2%FS/year
Response time (10 … 90%) 25ms 5mswiththeaccuracycodes6und7 (OrderingcodePosition5).
Temperature influence (in compensated range)
Dependingontheaccuracyclass:
Orderingcode,Position5=1and6(class0.4%) Zero: TC±0.20%FS/10K. Span: TC±0.15%FS/10K.
Orderingcode,Position5=2and7(class0.2%) Zero: TC±0.15%FS/10K. Span: TC±0.10%FS/10K.
Orderingcode,Position5=3(class0.1%) Zero: TC±0.05%FS/10K. Span: TC±0.05%FS/10K.
Orderingcode,Position5=AandB(hightemperature) Zero: TC±0.20%FS/10K. Span: TC±0.15%FS/10K.
Dependingonthewettedpartsmaterial:
Orderingcode,Position10=3and9 Zero: TC±0.30%FS/10K. Span: TC±0.20%FS/10K.
Admissible temperature of the medium
ED701 without integrated cooling neck (Ordering code Position 5: Code 1, 2, 3, 6 or 7): ED701withFDAwhiteoil: -10°C…+125°C ED701withsiliconorhalocarbonoil: -30°C…+125°C
ED701 with integrated cooling neck (Ordering code Position 5: Code A or B): Forhighmediumtemperature(120°Candhigher)theED701hastohaveanintegratedcoolingneck. ED701withcoolingneckwith FDAwhiteoil: -10°C…+200°C ED701withcoolingneckwithsiliconor halocarbonoil: -30°C…+300°C
Ambient temperature (housing)
-10°C…+80°C
Storage temperature
-10°C…+80°C
Sterilisation temperature (SIP Process)
Sterilisation:max.+140°C,max.30minutes
SterilisationCompletedevice,notpowered,onlyforexecutionswiththeFischerelectricalplug.Processdurationmax.60minutes,sterilisationtemperaturemax.140°C,pressure3500mbar,notpowered.
Materials specification
Wetted partStainlessSteel1.4435(AISI316L)
Parts not in contact with mediumStainlessSteel1.4301,1.4305andelectricalconnectormaterial.
Certificate EN102043.1availableonrequest
Electrical specification
Supply voltage 9...30VDC(4…20mA) 10...28VDC(4…20mAEEX) 14...24VDC(4...20mALloyd‘sRegister) 15...30VDC(0…10and0...5VDC) 20...24VDC(0…10and0...5VDCLloyd‘sRegister)
Insulation Resistance >1GOhm,500VDC
Load (currentoutput) RL50xUB-450Load(voltageoutput) RL5kOhm
Protected against reverse signal polarity.
Switch ON time5sec.
EMC
Influence of EMC Lessthan0.15%FS
Conformity EN61000-6-3,EN61000-6-2,EN61326, EN50121-4
ATEX data
IntrinsicallysafeconformingtoEN50020andEN50281-1-1Applications:
II1GII1D Devicelocatedinzone0/zone20
II1/2GII1D Pressureconnectioninzone0/zone20 Housingandelectricalconnectionin zone1/zone20
II2GII1D Devicelocatedinzone1/zone20
IntrinsicallysafetyEExiaIIC.Thedevicecanonlybeconnectedtoanapprovedintrinsicallysafecurrentloopwiththefollowingbounderyvalues:U0=28V Ik=100mA P=1.5WThedeviceinternalcapacityandinductivityvaluesare:Ci=1nF Li=0.1mH
FortheapplicationinEExzoneyouhavetorespecttheconditionsmentionedintheATEXTypeExaminationCertificate.Youfindthecertificatesandmanualsunderhttp://www.baumerprocess.com/en/downloads/.
Environmental specification
Humidity AccordingtoEN60068-2-38Vibrations AccordingtoEN60068-2-6Shocks AccordingtoEN60068-2-31
Protection class
RatingIP65andIP67,dependingonelectricalplug.
Mounting
Positionatcalibrationtime:Vertical
Physical characteristics
Weight Between223and885gdependingoftheversion.
DimensionsSeedrawings.
Disposal of product and packingAccordingtonationallawsorbyreturningtothemanufacturer.
www.baumerprocess.com DataSheet A11 D6.181
Designandspecificationssubjecttochangewithoutnotice Page7
Technical data
Zero adjustment and factory setting:
ThezeroadjustmentandfactorysettingaredirectlyavailableontheED701byremovingtheelectricalplug.Apushbuttononthetopoftheelectronicunitcanbeactivated.Zero adjustment:Bypressingthepushbuttontheappliedpressurewillbeconsideredasthenewzeropointandtheoutputsignalwillbereset(i.e.4mAor0VDC).Thisfunctionallowssomecorrectionsifthemountingpositioninfluencesthemeasurement,iftemperatureorlongtermdriftsoccursandifaresettinginalevelmeasurementapplicationisneeded.Factory setting(zero):Thefactorysettingcanbereloadedatanytime.Todoitthepushbuttonmustbepressedduringatleast10seconds.
Oil filling
Standard:ThestandardoilfillingistheFDAapprovedwhiteoil(Paraffinoil).Thisisthebestchoiceforalltheapplicationsinthefood,beverages,pharmaceuticalandbiotechindustries.Temperaturebelow-10°Candabove+200°Cshouldnotbeused,itcouldseverelydamagetheED701.Alternative:Thesiliconoilcanberecommendedforallgeneralindustrialapplicationsandcanbeusedinatemperaturerangefrom-30°Cupto+300°C.Foroxygenserviceorpaintingindustry,choosethehalocarbonoil.Halocarbonissiliconfreeandwithstandstemperaturesfrom-30°Cupto+300°C.Withthisparticularfilling,weguaranteethatallpartsthatmaybeincontactwiththemedium(e.g.incaseofdiaphragmdamage)aresiliconfree.Componentslocatedinsideofthesealedtransmitterhousingmaycontainsiliconinsolidform.
Pressure connection tightness with O-Ring
Themountingexamplesonthenextpagesshowtheappropriatetightnessmethodsforeachtypeofpressureconnection.AmetaltometalsealispossiblewiththepressureconnectionJandW.ThisuniqueBourdon-Haenniconeconstructionhastoberealizedusingtheadequateweldingsleeve(seeAccessories).ThepressureconnectionsKandZareusuallysealedbytheO-ringlocatedonthefrontoftheconnection.TheconnectionLiscompatiblewiththeCombiConnectsystemproposedbyBourdon-Haenni,allowingahygienicsealatthefrontoftheconnection.TheCombiConnectsystemconsistsofaseriesofhygienic,replaceableconnections.Moredetailsonrequest.AllthepressureconnectionsJ,K,L,W,ZcanalsobesealedbytheO-ringlocatedattherearofthethread(ortightnesssurface).
Lloyd‘s Register (LR)
TheED701hasbeentestedwithsatisfactoryresultsinaccordancewiththerequirementsoftheLRTypeApprovalSystem.
Certificate number: 06/20034.(Expires:29August2011).
Applications: Marine,offshoreandindustrialapplicationsforuseinenvironmentalcategoriesENV1,ENV2andENV3asdefinedinLloyd‘sRegister‘sTypeApprovalSystem,TestSpecificationNumber1-2002.
Limitations:ThesupplyvoltagerangeofED701isisreducedcomparedtothenonLRapprovedED701.(PleaserefertotheparagraphTechnicaldata-Electricalspecification).AccordingtothecurvebelowtheallowedambienttemperatureforLloyd‘sRegisterapprovedED701isderatedatmediumtemperaturesabove150°C.
80 ºC
T°ambient
AllowedZone
60 ºC
-10 ºC T° medium
150 ºC 200 ºC
www.baumerprocess.com DataSheet A11 D6.181
Designandspecificationssubjecttochangewithoutnotice Page8
30)Onlyforpressureranges 1barandaccuracyclasses0.2%and0.4%.31)Onlyforpressureranges 400mbarandwiththeaccuracyclass0.4%.32)Onlyforpressureranges 10barandwiththeaccuracyclassesAandB.33)Onlyforpressureranges 1bar.34)Onlyavailablewithsiliconoilorhalocarbonoil.
35)UseappropriateO-Ringorsealfortemperatureupto200°C.WerecommendViton®.
Viton®isaregisteredtrademarkofDuPontPerformanceElastomers
Available Availablewithrestrictions
Process connection availability – Overview table
Code Process connection Material Oil filling Accuracy
J MalethreadG1“flushdiaphragmwithcone 30) 30) 35) 35) 34)
K MalethreadG1“flushdiaphragmwithO’ring 30) 30) 35) 35)
L MalethreadG1⁄2“flushdiaphragmDIN3852 31) 33) 33) 31) 35) 35)
Z MalethreadG1⁄2“flushdiaphragmwithO’ring 31) 33) 33) 31)
W MalethreadG1⁄2“flushdiaphragmwithcone 32) 35) 35) 34)
F /9390ClampDIN11864-3,BKS,DN25DIN 35) 35)
F /9391ClampDIN11864-3,BKS,DN33.7ISO 35) 35)
H /9533ClampDIN32676,DN25,DN32,DN40 30) 30) 35) 35)
I /9402NeumoBioConnect®,FormV,DN48.3 35) 35)
N /9412ClampISO2852,DN21.3 31) 33) 33) 31) 35) 35)
N /9413ClampISO2852,DN25 31) 33) 33) 31) 35) 35)
N /9414ClampISO2852,DN33.7,DN38 30) 30) 35) 35)
N /9416ClampISO2852,DN40,DN51 30) 30) 35) 35)
N /9418ClampISO2852,DN63.5 30) 30) 35) 35)
Y /9451Tri-Clamp®3⁄4” 31) 33) 33) 31)
Y /9452Tri-Clamp®1” 31) 33) 33) 31) 35) 35)
Y /9453Tri-Clamp®11⁄2” 35) 35)
Y /9454Tri-Clamp®2” 35) 35)
8 MalethreadG1⁄2”EN837-1forpressureseal
9 MalethreadG1⁄4”EN837-1forpressureseal
0 /9483BBS,Quick-Connect,ISODN25 35) 35)
0 /9486Malethread1“-11.5NPTflushdiaphragm 35) 35)
1.44
35
Hast
ello
y-C
Stre
ngth
ened
dia
phra
gm
0.2%
FS
0.4%
FS
0.2%
for h
igh
med
ium
te
mpe
ratu
re (u
p to
200
°C)
FDA
Silic
on
Halo
carb
on
P <
1 b
ar
P
1 b
ar
0.1%
FS
0.4%
for h
igh
med
ium
te
mpe
ratu
re (u
p to
200
°C)
0.4%
for h
igh
med
ium
te
mpe
ratu
re (u
p to
300
°C)
Gold
pla
ted
www.baumerprocess.com DataSheet A11 D6.181
Designandspecificationssubjecttochangewithoutnotice Page9
Drawing (all dimensions in mm)
OnlyfororderingcodePosition5=AandB
Code l4
K, J 48L, W 50F /9390, F /9391 50I /9402 50N /9412, N /9413, N /9414 50N /9416, N /9418 500 /9483
DIN 43650 plugCode:4
34
17
Bendix 6 pole plugCode:5
34
17
Cable 3 conductorsIP 65 / IP 67 Code: 1(IP65) 9(IP67)
34
10.4
DIN 41524Binder plugCode:3
34
14
Fischer plugCode:2
Field housingCode:A,B,CandD
34 55
14.5
M12 industrial plugCode:6
34
10.4
55
NPT 3 conductorsCode:7
34
10
SW27
34
61.5
40
l 4
www.baumerprocess.com DataSheet A11 D6.181
Designandspecificationssubjecttochangewithoutnotice Page10
Drawing (all dimensions in mm)
Mounting example
einbau_g1_ohne_konus_D13708.dxf
Seal
Seal
Weldingsleeve
Pressureport
Screwhole
Pressureport
PressureportSeal
Pressureport
Screwhole
Clamp
Code Threadd1 d2 l1 l2
K G1” 30 12.5 20.5Z G1⁄2” 18 10.5 20.50 /9486 1“-11.5 NPT
Code Nominalsize d1 d2 l1H /9533 DN 25/32/40 50,5 24N /9412 DN 21,3 34 17,5 15N /9413 DN25 50,5 17.5 15N /9414 DN 33,7/DN 38 50,5 24 15N /9416 DN 40/DN 51 64 24 15N /9418 DN 63,5 77,5 24 15Y /9451 3⁄4” 24,9 16 31,7Y /9452 1” 50,4 17,5Y /9453 11⁄2” 50,4 24Y /9454 2” 63,9 240 /9483 ISO DN25 50,5 24
key41(TypK,and0/9486)key27(TypZ)
d2
d1
l 1
l 212
d1
l 1
d2diaphragm
key41(TypJ)key27(TypW)
d1
d2
l 1l 2
l 3
70°
Code Threadd2 l1 l2 l3
J G1” 25.5 18 9W G1⁄2” 15.2 13.7 9 16.5
key27
d2
d1
l 116
.5
l 2
Code Threadd1 d2 l1 l2
L G1⁄2” 17.5 16 2.5
Code Nominalsize d1 d2 l1F /9330 DN 25 DIN 50.5 24 15F /9331 DN 33.7 ISO 50.5 24 15
d1
l 1
d2diaphragm
Code Nominalsize d1 d2 l1I /9402 100 24
d1
d2diaphragm
www.baumerprocess.com DataSheet A11 D6.181
Designandspecificationssubjecttochangewithoutnotice Page11
Accessories
Connecting diagram
Electrical connection
ForVoltagesignalOutput0…max.10V For4...20mAcurrentloopversion
a
b
c
d
IA
UA RL
UB UB
RLIA
a
b
d
Pin assignment
Contact Fischer plug NPT 3 conductors M12 industrial plug Field housing
4...20mA 0...5/10VDC 4...20mA 0...5/10VDC 4...20mA 0...5/10VDC 4...20mA 0...5/10VDCa 1 1 Red Red 3 3 1 1b 2 2 Black Black 1 1 2 2c - 3 - Green - 4 - 3d Case Case Case Case 4 4
Viewsolderingside,cablesocket
Welding sleeves
Code D a H Material Ordering code J G1” 55 23 Stainlesssteel1.4435 D 11737.0002 J G1” 55 23 HastelloyC D 11737.0022 W G1⁄2” 35 20 Stainlesssteel1.4435 D 11737.0000 W G1⁄2” 35 20 HastelloyC D 11737.0020
Code D a H Material Ordering code
K G1” 60 20.5 Stainlesssteel1.4435 D 12403.1 Z G1⁄2” 60 20.5 Stainlesssteel1.4435 D 12403.0
Front piece with thread
Code D a b sw Material Ordering code J G1” 18 27 41 Stainlesssteel1.4435 D 11870.0002 J G1” 18 27 41 HastelloyC D 11870.0022 W G1⁄2” 12 23 27 Stainlesssteel1.4435 D 11870.0000 W G1⁄2” 12 23 27 HastelloyC D 11870.0020
aD
H
Pin assignment
Contact DIN 43650 plug Bendix 6 poles plug Cable 3 conductors DIN 41524 Binder plug
4...20mA 0...5/10VDC 4...20mA 0...5/10VDC 4...20mA 0...5/10VDC 4...20mA 0...5/10VDCa 1 1 B B Blue Blue 3 3b 2 2 E E Brown Brown 1 1c - 3 - D - Black - 4d GND GND Case Case Shield Shield Case Case
Viewsolderingside,cablesocket
red blackgreen
blue
blackbrown
shield
www.baumerprocess.com DataSheet A11 D6.181
Designandspecificationssubjecttochangewithoutnotice Page12
Electrical sockets
Description Ordering codeCablesocketconnectorDIN43650 E 6844.0
Description Ordering codeCablesocketconnectorBinder E 13265.0
Description Ordering codeCablesocketconnectorBendix E 6586.1
Description Ordering codeCablesocketconnectorM12 E 15560.0
Cable Ordering codeCablewithM12socketconnectorforED701 E 15543.x LLL
Type ShieldedPVCKabel 0 ShieldedPURKabel 1 Length 2meters 002 5meters 005 10meters 010 20meters 020
Description Ordering codeCablesocketconnectorM12 E 15560.1
Accessories
Description Ordering codeCablesocketconnectorFischer E 13267.0
O-Rings
TheFDAapprovedO-ringsareavailableinNBR,EPDMandViton®(FPM).Theyaredeliveredinpacksof5units.
ThefollowingoperatingtemperatureoftheO-ringsareonlyindicativevalues(dryair):NBR(FDA): –25°…+125°CEPDM(FDA): –40°…+160°CFPM/Viton®(FDA): –20°…+200°C
Process connection Designation Material Ordering code
L,W,Z O-RingformalethreadG1⁄2”(attherear) NBR(FDA) A8550.9110L,W,Z O-RingformalethreadG1⁄2”(attherear) FPM/Viton®(FDA) A8550.9111L,W,Z O-RingformalethreadG1⁄2”(attherear) EPDM(FDA) A8550.9112J,K O-RingfürG1”(attherear) NBR(FDA) A8550.9120J,K O-RingfürG1”(attherear) FPM/Viton®(FDA) A8550.9121J,K O-RingfürG1”(attherear) EPDM(FDA) A8550.9122K O-RingfürG1”(onthefront) NBR(FDA) A8550.9130K O-RingfürG1”(onthefront) FPM/Viton®(FDA) A8550.9131K O-RingfürG1”(onthefront) EPDM(FDA) A8550.9132Z O-RingfürG1⁄2”(onthefront) NBR(FDA) A8550.9140Z O-RingfürG1⁄2”(onthefront) FPM/Viton®(FDA) A8550.9141Z O-RingfürG1⁄2”(onthefront) EPDM(FDA) A8550.9142
Accessories for CombiConnect
SeeDataSheet3400-3,FlexbarHRTaccessories.
Viton®isaregisteredtrademarkofDuPontPerformanceElastomers
35
9
35
9
52.5
35
2
0
M12
x1
SW
19
D6.
181/
UK
/200
8-09
-22
This
dat
ash
eet
may
onl
yb
ere
pro
duc
edin