6
® ASSA ABLOY In U.S.: Corbin Russwin, Inc. 225 Episcopal Road Berlin, CT 06037 USA www.corbinrusswin.com In Canada: ASSA ABLOY Door Security Solutions Canada 160 Four Valley Drive Vaughan, Ontario, Canada L4K4T9 www.assaabloy.ca Technical Product Support: Phone: 888-607-5703 Installation Instructions 1 of 6 Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. ED3200/ED3200A Series Rim Exit Device FM362 (05/15) FM362 (05/15) Inactive Case Cover Hex Dogging Key Active Case Chassis Active Case Cover Crossbar Inactive Case Chassis Plug Locking Screw Locking Screw LHR Left Hand Reverse Hinges Left Open Outward RHR Right Hand Reverse Hinges Right Open Outward Check Application For Proper Hand And Function. If Required, Adjust Exit Device As Follows: Tools Required 1. Measuring tape 2. Power drill 3. Drill bits: 3/32",1/4",11/32", 3/8", #25 4. Taps:#10-24 5. Screwdrivers: Phillips #2 and #3 To view helpful video installation tips, scan the Microsoft® Tags with your mobile phone. Download the free mobile app at http://getscanlife.com.

ED3200/ED3200A Series...2. Mount chassis to door as indicated in Figures 3 and 4. 1. Press in latchbolt and remove cover from active case chassis. 2. Mount chassis to door as indicated

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ED3200/ED3200A Series...2. Mount chassis to door as indicated in Figures 3 and 4. 1. Press in latchbolt and remove cover from active case chassis. 2. Mount chassis to door as indicated

®

ASSA ABLOYIn U.S.:Corbin Russwin, Inc.225 Episcopal RoadBerlin, CT 06037 USAwww.corbinrusswin.com

In Canada:ASSA ABLOY Door Security Solutions Canada160 Four Valley DriveVaughan, Ontario, Canada L4K4T9www.assaabloy.ca

Technical Product Support: Phone: 888-607-5703

Installation Instructions

1 of 6Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express writtenpermission of Corbin Russwin, Inc. is prohibited.

ED3200/ED3200A Series Rim Exit Device

FM362 (05/15)

FM362 (05/15)

Inactive CaseCover

Hex Dogging Key

Active CaseChassis

Active CaseCover

Crossbar

Inactive CaseChassis

Plug

LockingScrew

LockingScrew

LHR Left Hand Reverse

Hinges Left Open Outward

RHR Right Hand Reverse

Hinges Right Open Outward

Check Application For Proper Hand And Function. If Required, Adjust Exit

Device As Follows:

Tools Required1. Measuring tape2. Power drill3. Drill bits: 3/32",1/4",11/32", 3/8", #254. Taps:#10-245. Screwdrivers: Phillips #2 and #3

To view helpful video installation tips, scan the Microsoft® Tags with your mobile phone. Download the free mobile app at http://getscanlife.com.

Page 2: ED3200/ED3200A Series...2. Mount chassis to door as indicated in Figures 3 and 4. 1. Press in latchbolt and remove cover from active case chassis. 2. Mount chassis to door as indicated

®

ASSA ABLOY

2 of 6Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express writtenpermission of Corbin Russwin, Inc. is prohibited.

ED3200/ED3200A Series Rim Exit Device

To Change Hand

A Unscrew Pivot andRemove SpringSupport Assembly

Pivot

B Unscrew Pivot - Remove Latch Bolt and Reassemble It On Opposite Side

C Reassemble Spring Support Assembly On Opposite Side (Make Sure Spring Rides On Latch Bolt Tail)

RHRB SHOWN

FM362 (05/15)

Identify type of installation todetermine location of vertical CL

Single Door (Non-Fire Rated)

Door

Vertical reference line(C of chassis)L

For Standard strike Dim. “A” = 2-1/4"

For S04 strike Dim. “A” = 1-3/4"

Double Door with 900 Mullion

Door Door

Vertical referenceline (C of chassis)LStandard Strike

Double Doors With No Mullion

Vertical Centerline of Active Case

2-1/4"

DOOR

Use Strike S02

Identify Type of Installation

Page 3: ED3200/ED3200A Series...2. Mount chassis to door as indicated in Figures 3 and 4. 1. Press in latchbolt and remove cover from active case chassis. 2. Mount chassis to door as indicated

®

ASSA ABLOY

ED3200/ED3200A Series Rim Exit Device

A. Template

38-5/8" Above Finished Floor

1. Draw vertical centerline of active case based on types of installation.

2. Measure 37-5/8" above finished floor and draw horizontal line for active case template.

3. Align template (T31207) for active case with centerline and tape.

4. Using crossbar hole centers for measuring, draw vertical centerline of inactive case.

5. Measure 38-5/8" above finished floor and draw horizontal line for inactive case template (1" higher than the active case).

6. Align template (T31206) for inactive case with centerline and tape.

7. Pin punch mounting holes for active and inactive cases on door.

8. Drill and tap holes in door, per the template (T31207).

TapeHorizontal Cof Inactive Case

Holes

L

L

L

Inside Faceof Door

Vertical C of Inactive Case

TEMPLATE

TEMPLATE

Locate Templates This Distance Apart

37-5/8" Above Finished Floor

Vertical C of Active CaseT31206

T31207

3 of 6Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express writtenpermission of Corbin Russwin, Inc. is prohibited.

FM362 (05/15)

Page 4: ED3200/ED3200A Series...2. Mount chassis to door as indicated in Figures 3 and 4. 1. Press in latchbolt and remove cover from active case chassis. 2. Mount chassis to door as indicated

ED3200/ED3200A Series Rim Exit Device

C. Inactive Case

1. Remove cover.

2. Mount chassis to door as indicated in Figures 3 and 4.

1. Press in latchbolt and remove cover from active case chassis.

2. Mount chassis to door as indicated in Figures 1 and 2.

3. Depress the chassis arm to confirm the latchbolt retracts.

B. Active Case

ChassisArm Figure 2

HingeSide

Active CaseSide

(Away fromDoor Hinge)

Figure 1

Figure 4

Figure 3

HingeSide

Inactive CaseSide

(Near DoorHinge)

4 of 6Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express writtenpermission of Corbin Russwin, Inc. is prohibited.

Active Case Mounting Screws - Actual SizeWood:

#10 x 1-1/4" Phillips

Flat Head(Total 4)

Metal:#10-24 x 3/4" Phillips Flat Under Cut(Total 4)

Active Case Mounting Screws - Actual Size

Inactive Case Mounting Screws - Actual Size

Metal:#10-24 x 3/4" Phillips Flat Under Cut(Total 4)

Inactive Case Mounting Screws - Actual Size

Wood:#10 x 1-1/4"

Phillips Flat Head(Total 4)

FM362 (05/15)

®

ASSA ABLOY

Page 5: ED3200/ED3200A Series...2. Mount chassis to door as indicated in Figures 3 and 4. 1. Press in latchbolt and remove cover from active case chassis. 2. Mount chassis to door as indicated

ED3200/ED3200A Series Rim Exit Device

1. Slide thrubolt screws thru inside chassis.

2. Thread cylinder into outside trim (if applicable).

3. Align outside trim with exposed thrubolt screws and secure.

D. Attach Outside Trim

NOTE:For Nightlatch function, secure cylinder to chassis. This method allows cylinder to be removed at a later date for rekeying without taking device off door.

1/4 -20 x 2-3/8" Phillips

Flat Head(Total 2)

Outside Trim Mounting Screws - Actual Size#10-24 x 2" Phillips Oval

Head MachineScrew

(Total 2)

Cylinder Mounting Screws - Actual Size

5 of 6Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express writtenpermission of Corbin Russwin, Inc. is prohibited.

FM362 (05/15)

1. Attach covers to both chassis and secure.

E. Covers

Inactive Chassis Active Chassis

#8-32 x 7/32" Phillips Oval

Head (Total 8)

Cover Mounting Screws - Actual Size

®

ASSA ABLOY

Page 6: ED3200/ED3200A Series...2. Mount chassis to door as indicated in Figures 3 and 4. 1. Press in latchbolt and remove cover from active case chassis. 2. Mount chassis to door as indicated

ED3200/ED3200A Series Rim Exit Device

1. Slide crossbar into active chassis arm.

2. Slide crossbar into inactive chassis arm.

3. Insert plugs and secure to bar with locking screws.

4. Depress the crossbar to confirm proper operation.

5. Test for full latch retraction when dogged.Cross Bar

Arm

Plug

LockingScrew

Crossbar Mounting Screws - Actual Size#10-24 x 3/4" Socket Head Cap Screw

(Total 2)

FM362 (05/15)6 of 6Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express writtenpermission of Corbin Russwin, Inc. is prohibited.

F. Crossbar

G. Strike

1. Align strike onto door frame and adjust for proper position.

2. Center punch mounting holes.

3. Drill and tap holes in frame.

4. Secure strike in place.

5. Standing inside the room, close door and confirm latchbolt fully engages.

Note: If latchbolt does not fully engage, review installation measurements of active and inactive chassis, and strike.

®

ASSA ABLOY