Editor: Leonid Förster Version: 2.04 EN Date: 8.Dec ´15 Page: 1
Quick-start manual DSP192-4-111
___________________________________________________________________________________
_________________________________________________________________________________________________________________________________ ALL RIGHT RESERVED – ALL DATA WITH RESERVATION AND SUBJECT TO CHANGE. FOR SUPPORT, PLEASE CONTACT [email protected]
© Thiel & Partner GmbH
Editor: Leonid Förster Version: 2.04 EN Date: 8.Dec ´15 Page: 2
Quick-start manual DSP192-4-111
___________________________________________________________________________________
Please follow steps 1 – 5 for proper installation. Step 1: Connecting Amps and power supplies via J7 or J4
Connect the DSP192-4-111 to your amplifier and power supply via connectors J7 or J4. For PASCAL amplifiers, use J7 with S-PRO modules or J4 with M-PRO / X-PRO modules. These modules already provide the power supplies for the DSP192-4-111. For all other amplifiers and supplies, please refer to the pinout tables for J7 and J4.
- Please check connections and supply voltages carefully, before you power-up -
J4 J7
PIN PIN DESCRIPTION DESCRIPTION
PIN PIN DESCRIPTION DESCRIPTION
1 2 ANALOG OUT CH. 4 AGND 1 2 GND ANALOG OUT CH.1
3 4 ANALOG OUT CH. 1 GND 3 4 AGND AGND
5 6 AGND ANALOG OUT CH. 2 5 6 ANALOG OUT CH. 2 TEMP_MONITOR
7 8 GND AGND 7 8 NOT CONNECTED NOT CONNECTED
9 10 ANALOG OUT CH. 3 GND 9 10 CLIP 1 CLIP 2
11 12 UOUT 1 UOUT 2 11 12 DIS_READ/PROTECT NOT CONNECTED
13 14 UOUT 3 IOUT 1 13 14 MUTE_DIS NOT CONNECTED
15 16 IOUT 2 IOUT 3 15 16 NOT CONNECTED STANDBY
17 18 TEMP_MONITOR GND 17 18 +V_DIGITAL: 6.5-12V +V_DIGITAL: 6.5-12V
19 20 GND CLIP 1 19 20 GND GND
21 22 CLIP2 CLIP 3 21 22 +V_ANALOG: +15V +V_ANALOG: +15V
23 24 GND DIS_READ/PROTECT 23 24 GND GND
25 26 GND MUTE_DIS 25 26 -V_ANALOG: -15V -V_ANALOG: -15V
27 28 CLIP_OFF SMPS_LIMIT
29 30 TEMP_REDUCT_OFF STANDBY
31 32 +V_DIGITAL: 6.5-12V +V_DIGITAL: 6.5-12V
33 34 GND GND
35 36 +V_ANALOG: +15V +V_ANALOG: +15V
37 38 GND GND
39 40 -V_ANALOG: -15V -V_ANALOG: -15V
_________________________________________________________________________________________________________________________________ ALL RIGHT RESERVED – ALL DATA WITH RESERVATION AND SUBJECT TO CHANGE. FOR SUPPORT, PLEASE CONTACT [email protected]
© Thiel & Partner GmbH
Editor: Leonid Förster Version: 2.04 EN Date: 8.Dec ´15 Page: 3
Quick-start manual DSP192-4-111
___________________________________________________________________________________
Step 2: Connecting the DSP192-4-111 to a PC via Ethernet
There are two different ways to connect the DSP192-4-111 to a PC via Ethernet: - Direct LAN connection (Step 2.1) DSP <-> PC - Connection via a LAN router (Step 2.2) DSP <-> LAN-Router <-> PC Connect the Ethernet cables according to one of these options. Switch on the power supply of the DSP. The network settings on the PC and on the DSP have to match. Either the IP-address of the PC needs to be changed according to the DSP address (Step 2.1) or the DSP address has to be changed according to the router settings (Step 2.2). In both cases the IP-addresses of DSP and PC must be equal in the first 9 digits and must be different in the last three digits, e.g. [192.168.010.010] and [192.168.010.113]. By default the IP-address of the DSP is [192.168.010.010].
_________________________________________________________________________________________________________________________________ ALL RIGHT RESERVED – ALL DATA WITH RESERVATION AND SUBJECT TO CHANGE. FOR SUPPORT, PLEASE CONTACT [email protected]
© Thiel & Partner GmbH
Editor: Leonid Förster Version: 2.04 EN Date: 8.Dec ´15 Page: 4
Quick-start manual DSP192-4-111
___________________________________________________________________________________
2.1. Direct LAN connection: This is the most quick and most reliable way to establish a connection between the PC and the DSP. The drawback of this method is however, that the IP-address of your computer has to be changed according to the setting of the DSP
Go to network settings in the control panel of your computer.
Right-click on the network adapter where your DSP is connected to.
Open ´properties’
Select TCP/IPv4 and open ‘properties’.
Choose “Use the following IP-address”, type in e.g. 192.168.010.009, subnet mask 255.255.255.000
o This assumes the IP-address of the DSP is 192.168.010.010. Make sure that the PC-address only differs in the last three digits.
Confirm all changes by closing the dialogues.
In most cases the PC was initially configured in such a way that it obtains the IP-address from the router automatically. By applying the above procedure the IP-address of the PC will be fixed. Most probably the PC will not be able to connect to the internet any more. This is quickly solved however.
Disconnect the Ethernet cable from the DSP and reconnect to your usual configuration.
Follow the above instructions but finally reactivate the options: o Obtain an IP address automatically o Obtain DNS server address automatically.
_________________________________________________________________________________________________________________________________ ALL RIGHT RESERVED – ALL DATA WITH RESERVATION AND SUBJECT TO CHANGE. FOR SUPPORT, PLEASE CONTACT [email protected]
© Thiel & Partner GmbH
Editor: Leonid Förster Version: 2.04 EN Date: 8.Dec ´15 Page: 5
Quick-start manual DSP192-4-111
___________________________________________________________________________________
2.2. Internet LAN connection: In this case the IP-address of your DSP is matched according to the IP-settings of your network, or of your LAN router to be specific. Find out the IP-address of your Computer.
Go to network settings in the control panel of your compute.
Right-click on the network adapter where your DSP is connected to.
Open ´status’
Click on ´details´ and read the IPv4-address of your computer.
The DSP IP-address needs to be set into the same range now, only the last 3 digits must remain different. Example: PC IP: 192.168.0.39 -> DSP IP 192.168.0.201 Change the IP-address of the DSP.
Push on the Volume / Menu knob on the DSP board. (See step 5 for all DSP knob functions.)
Turn the knob to point ´3: SET IP´.
Push the knob and set the new IP-address.
Press the knob for 3 seconds after setting to safe the new IP-address.
Please check it was saved by entering point ´3: SET IP´ again and see if it shows the new IP. NOTE: It is recommended to set the last 3 digits to > 200 (255 is always the maximum value). This will reduce the probability that some other device in the network has the same IP-address. (Look for the manual of your router for more details.)
_________________________________________________________________________________________________________________________________ ALL RIGHT RESERVED – ALL DATA WITH RESERVATION AND SUBJECT TO CHANGE. FOR SUPPORT, PLEASE CONTACT [email protected]
© Thiel & Partner GmbH
Editor: Leonid Förster Version: 2.04 EN Date: 8.Dec ´15 Page: 6
Quick-start manual DSP192-4-111
___________________________________________________________________________________
Step 3: Connecting NetControl with attached devices
Install the NetControl software if not happened yet. Starting the software opens the following user interface.
Right-click on Interfaces -> choose Scan Network -> the “Scan Network” dialogue is opened
Scan network
_________________________________________________________________________________________________________________________________ ALL RIGHT RESERVED – ALL DATA WITH RESERVATION AND SUBJECT TO CHANGE. FOR SUPPORT, PLEASE CONTACT [email protected]
© Thiel & Partner GmbH
Editor: Leonid Förster Version: 2.04 EN Date: 8.Dec ´15 Page: 7
Quick-start manual DSP192-4-111
___________________________________________________________________________________
In the dialogue: 1. Type in a range of IP-addresses around the IP-address of the DSP. 2. Click the “Start scanning” button
→ NetControl scans for devices within the specified range → All found devices are listed in the main part of the dialogue
3. Click the “Add devices” button -> NetControl connects to all listed devices 4. If NetControl cannot find any devices pleas go back to section 2 and check the IP-settings.
1
2
3
_________________________________________________________________________________________________________________________________ ALL RIGHT RESERVED – ALL DATA WITH RESERVATION AND SUBJECT TO CHANGE. FOR SUPPORT, PLEASE CONTACT [email protected]
© Thiel & Partner GmbH
Editor: Leonid Förster Version: 2.04 EN Date: 8.Dec ´15 Page: 8
Quick-start manual DSP192-4-111
___________________________________________________________________________________
After closing the dialogue the device that has been added is listed in the device list window. The green status LED “ONLINE” in the device manager window shows the connection status, being green when connected properly.
new
device
connection
ok
_________________________________________________________________________________________________________________________________ ALL RIGHT RESERVED – ALL DATA WITH RESERVATION AND SUBJECT TO CHANGE. FOR SUPPORT, PLEASE CONTACT [email protected]
© Thiel & Partner GmbH
Editor: Leonid Förster Version: 2.04 EN Date: 8.Dec ´15 Page: 9
Quick-start manual DSP192-4-111
___________________________________________________________________________________
Step 4: Configuring the DSP192-4-111 using NetControl When working with NetControl for the first time simply concentrate on the upper part of the user interface. Here the device parameters are configured:
Click directly on the signal-flow blocks or menu tabs in order to control the following functions. All parameters and settings are automatically transferred to the device.
BLOCK DESCRIPTION FUNCTION
ONLINE / OFFLINE INDICATOR
THE GREEN (RED) LED INDICATES THAT THE DEVICE IS CURRENTLY CONNECTED TO (DISCONNECTED FROM) THE NETCONTROL SOFTWARE
MUTE (IN / OUT) MUTE / UNMUTE INPUT AND OUTPUT CHANNELS
GAIN (IN / OUT) SET THE GAIN FOR INPUT AND OUTPUT CHANNELS
DELAY (IN / OUT) SET THE DELAY FOR INPUT AND OUTPUT CHANNELS
IIR FILTERS (IN / OUT) SET IIR FILTERS
INPUT CHANNELS E.G. FOR ROOM CORRECTION OUTPT CHANNELS E.G. FOR DRIVER LINEARIZATION
FIR-FILTERS (IN / OUT) SET FIR FILTERS FOR INPUT AND OUTPUT CHANNELS
ROUTING
ASSIGN INPUT CHANNELS TO OUTPUT CHANNELS
XOVER FUNCTIONS (OUT)
SET XOVER FUNCTIONS FOR EACH OUTPUT CHANNEL
DYNAMIC LIMITERS (OUT)
SET PEAK AND RMS LIMITERS FOR EACH OUTPUT CHANNEL
PHASE (OUT)
SET THE PHASE SHIFT FOR EACH OUTPUT CHANNEL
device
parameters
menu tabs
signal flow
blocks
_________________________________________________________________________________________________________________________________ ALL RIGHT RESERVED – ALL DATA WITH RESERVATION AND SUBJECT TO CHANGE. FOR SUPPORT, PLEASE CONTACT [email protected]
© Thiel & Partner GmbH
Editor: Leonid Förster Version: 2.04 EN Date: 8.Dec ´15 Page: 10
Quick-start manual DSP192-4-111
___________________________________________________________________________________
4.1 Permanently storing the settings on the device: The settings will then be reloaded each time the device is switched on again.
Select a preset slot in the drop-down menu .
Edit the preset name according to your preferences .
Press the store button .
The device confirms the new preset by displaying the new preset name in the display.
NetControl as well shows the currently active preset . For more detailed information, please check the extended NetControl manual.
_________________________________________________________________________________________________________________________________ ALL RIGHT RESERVED – ALL DATA WITH RESERVATION AND SUBJECT TO CHANGE. FOR SUPPORT, PLEASE CONTACT [email protected]
© Thiel & Partner GmbH
Editor: Leonid Förster Version: 2.04 EN Date: 8.Dec ´15 Page: 11
Quick-start manual DSP192-4-111
___________________________________________________________________________________
Step 5: Rotary-push encoder functions of the DSP192-4-111
The rotary-push encoder on the DSP board has the following functions:
ACTION FUNCTION
VOLUME ROTATE VOLUME IN STEPS OF 0.1 dB
ROTATE 1x, PUSH, ROTATE VOLUME IN STEPS OF 0.5 dB
MENU
PUSH, ROTATE 1x MENU POINT 1: VOLUME CONTROL
PUSH, ROTATE 2x MENU POINT 2: LOAD PRESET
PUSH, ROTATE 3x MENU POINT 3: SET IP
PUSH, ROTATE 4x MENU POINT 4: SELECT INPUT
PUSH, ROTATE 5x MENU POINT 5: SYSTEM TEMP
PUSH, ROTATE 6x MENU POINT 6: BACKLIGHT
PUSH, ROTATE 7x MENU POINT 7: INFO
Changes in the menu must be saved by pushing the knob for approximately 2 sec. until the display returns to the default mode.
_________________________________________________________________________________________________________________________________ ALL RIGHT RESERVED – ALL DATA WITH RESERVATION AND SUBJECT TO CHANGE. FOR SUPPORT, PLEASE CONTACT [email protected]
© Thiel & Partner GmbH
Editor: Leonid Förster Version: 2.04 EN Date: 8.Dec ´15 Page: 12
Quick-start manual DSP192-4-111
___________________________________________________________________________________
© 2015, Thiel & Partner GmbH Rommerskirchenerstr. 21
De 50259 Pulheim Tel: +49 (0)2238/475475 Fax: +49 (0)2238/475476 Email: [email protected] Web: www.accuton.de
Copies, translations, alteration of any sort or conversions in electronic media or machine-readable forms are prohibited without previous, explicit approval by Thiel & Partner GmbH. All brand names are property of their respective owners. Thiel & Partner is not responsible for damages to software, hardware or data and any resulting losses which were caused by inappropriate manipulation or installation of the software. Technical specifications subject to change without notice.