1 -What is meaning of Quality & Quality control & quality assurance?

2 - Why Is Calibration?

3 - What Is Calibration? 4 - What are types of calibration laboratory?

5 - Control of the calibration environment.

6 - Important Expression.

7- Standard unit

8 - Calibration certificate.

9 -ISO/TS 16949 , ISO 9001, ISO 17025 , accreditation Requirements in calibration.

Contents

Page 3: EGA E gyptian G erman A utomotive Co. A DaimlerChrysler Industrial J.V. 1 THE CALIBRATION

EGAEgyptian German Automotive Co.

A DaimlerChrysler Industrial J.V.

3

Product quality depend on: Measuring instrument accuracy (uncertainity)

-If the confidence level of your measurement process is low, you will be

accepting some bad products and rejecting another good ones .OR

producing some out of specifications products.

2- Why Is Calibration?

3 - What Is Calibration?

Comparing the output of the process instrument being calibrated against the out put of a standard instrument of known accuracy.

Page 4: EGA E gyptian G erman A utomotive Co. A DaimlerChrysler Industrial J.V. 1 THE CALIBRATION

EGAEgyptian German Automotive Co.

A DaimlerChrysler Industrial J.V.

4

4 - What are types of calibration laboratory

• Mass and Dimension• Mechanical• Electrical• Thermal

Measuring instrument accuracy depend on periodic calibration to assure

that manufacture specifications (instrument accuracy) are met .

Calibration plan

Page 5: EGA E gyptian G erman A utomotive Co. A DaimlerChrysler Industrial J.V. 1 THE CALIBRATION

EGAEgyptian German Automotive Co.

A DaimlerChrysler Industrial J.V.

5

5-Control of the calibration environment :

• Humidity : In general (20 %-50% RH)• Temperature 20 ºc• Dust Levels• Electrostatic Discharge( ESD)• Vibration

Page 6: EGA E gyptian G erman A utomotive Co. A DaimlerChrysler Industrial J.V. 1 THE CALIBRATION

EGAEgyptian German Automotive Co.

A DaimlerChrysler Industrial J.V.

6

- What is meaning of: Accuracy & Precision?

- Inaccurate- imprecise

- Inaccurate- precise

- Accurate- precise

6-1 Important Expression

Accuracy:The closeness of the agreement between the result of measurement and the true value of the measurand.Precision: A measurement of consistency or repeatability of a set of measurements (freedom from random error).

Page 7: EGA E gyptian G erman A utomotive Co. A DaimlerChrysler Industrial J.V. 1 THE CALIBRATION

EGAEgyptian German Automotive Co.

A DaimlerChrysler Industrial J.V.

7

2-Resolution of the measurement: The degree to which a measurement can be determined .

1-Sensitivity:

Is the minimum input that will result in a discernible change in an output.

Scale deflection /value of measured quantity causing deflection .

What is meaning of: Sensitivity& Resolution?

6-2 Important Expression

Page 8: EGA E gyptian G erman A utomotive Co. A DaimlerChrysler Industrial J.V. 1 THE CALIBRATION

EGAEgyptian German Automotive Co.

A DaimlerChrysler Industrial J.V.

8

• Linearity:

1- zero drift

2- sensitivity drift

3- zero drift + sensitivity drift.

• Dead space:

6-3 Important Expression

Page 9: EGA E gyptian G erman A utomotive Co. A DaimlerChrysler Industrial J.V. 1 THE CALIBRATION

EGAEgyptian German Automotive Co.

A DaimlerChrysler Industrial J.V.

9

Traceability Chain

Fied Calibration Activity

Calibration Laboratory

Standard Laboratory

prim ary sandard laboratory

Natioal Instite S tandads TechnologyNIST

6-4 Important Expression

uncertainty For micrometer =1 in 109

uncertainty For micrometer =1 in 105

uncertainty For micrometer =1 in 106

uncertainty For micrometer =1 in 107

uncertainty For micrometer =1 in 104

Page 10: EGA E gyptian G erman A utomotive Co. A DaimlerChrysler Industrial J.V. 1 THE CALIBRATION

EGAEgyptian German Automotive Co.

A DaimlerChrysler Industrial J.V.

10

7-Standard Unit

Page 11: EGA E gyptian G erman A utomotive Co. A DaimlerChrysler Industrial J.V. 1 THE CALIBRATION

EGAEgyptian German Automotive Co.

A DaimlerChrysler Industrial J.V.

11

8-Calibration certificate

Each certificate or report shall include at least the following information's :-

-Estimated uncertainty of calibration.

-Traceability .

- Measurements, examinations , supported by tables, graphs.

-Reference to methods and sampling procedures.

-Condition of the calibration………….

Page 12: EGA E gyptian G erman A utomotive Co. A DaimlerChrysler Industrial J.V. 1 THE CALIBRATION

EGAEgyptian German Automotive Co.

A DaimlerChrysler Industrial J.V.

12

ISO 9001:2000, Quality management systems – Requirements

7.6 Control of monitoring and measuring devices

The organization shall determine the monitoring and measurement to be

undertaken and the monitoring and measuring devices needed to provide evidence

of conformity of product to determined requirements (see 7.2.1).

The organization shall establish processes to ensure that monitoring and

measurement can be carried out and are carried out in a manner that is consistent

with the monitoring and measurement requirements.

Where necessary to ensure valid results, measuring equipment shall

a) be calibrated or verified at specified intervals, or prior to use, against

measurement standards traceable to international or national measurement

standards; where no such standards exist, the basis used for calibration or

verification shall be recorded;

b) be adjusted or re-adjusted as necessary;

c) be identified to enable the calibration status to be determined;

d) be safeguarded from adjustments that would invalidate the measurement result;

e) be protected from damage and deterioration during handling, maintenance and

storage.

In addition, the organization shall assess and record the validity of the previous

measuring results when the equipment is found not to conform to requirements.

The organization shall take appropriate action on the equipment and any product

affected. Records of the results of calibration and verification shall be maintained

(see 4.2.4).

When used in the monitoring and measurement of specified requirements, the

ability of computer software to satisfy the intended application shall be confirmed.

This shall be undertaken prior to initial use and reconfirmed as necessary.

NOTE See ISO 10012-1 and ISO 10012-2 for guidance.

ISO/TS 16949 and ISO 9001 Requirements in calibration.

Page 13: EGA E gyptian G erman A utomotive Co. A DaimlerChrysler Industrial J.V. 1 THE CALIBRATION

EGAEgyptian German Automotive Co.

A DaimlerChrysler Industrial J.V.

13

7.6.1 Measurement system analysis

Statistical studies shall be conducted to analyse the variation present in the results of each type of

measuring and test equipment system. This requirement shall apply to measurement systems

referenced in the control plan. The analytical methods and acceptance criteria used shall conform

to those in customer reference manuals on measurement systems analysis. Other analytical

methods and acceptance criteria may be used if approved by the customer.

7.6.2 Calibration/verification records

Records of the calibration/verification activity for all gauges, measuring and test equipment,

needed to provide evidence of conformity of product to determined requirements, including

employee- and customer-owned equipment, shall include equipment identification, including the measurement standard against which the

equipment is calibrated, revisions following engineering changes, any out-of-specification readings as received for calibration/verification, an assessment of the impact of out-of-specification condition, statements of conformance to specification after calibration/verification, and notification to the customer if suspect product or material has been shipped.

7.6.3 Laboratory requirements

7.6.3.1 Internal laboratory

An organization’s internal laboratory facility shall have a defined scope that includes its capability

to perform the required inspection, test or calibration services. This laboratory scope shall be

included in the quality management system documentation. The laboratory shall specify and

implement , as a minimum, technical requirements for adequacy of the laboratory procedures, competency of the laboratory personnel, testing of the product , capability to perform these services correctly, traceable to the relevant process standard

(such as ASTM, EN,…), and, review of the related records.

NOTE Accreditation to ISO/IEC 17025 may be used to demonstrate supplier in-house laboratory

conformity to this requirement but is not mandatory.

7.6.3.2 External laboratory

External/commercial/independent laboratory facilities used for inspection, test or calibration

services by the organization shall have a defined laboratory scope that includes the capability to

perform the required inspection, test or calibration, and there shall be evidence that the external laboratory is acceptable to the customer, or the laboratory shall be accredited to ISO/IEC 17025 or national equivalent.