EICKEMEYER II DENTAL POLISHER / DRILL
MANUAL
TELEFON +49 7461 96580 0
www.eickemeyer.com
Art. Nr. 174028
Manual EICKEMEYER II dental polisher/ drill
2/6
1 General Please read the manual carefully. The unit may only be operated and looked after by trained members of
staff. The unit may only be opened by trained service engineers authorised by the manufacturer.
The unit must be kept clear of liquids and may only be run with the indicated voltage (220-240 V).
2 Product description
Part name:
1. Speed control dial
2. Control box
3. Forward-Reverse switch
4. Voltage chnage switch
5. Power switch
6. Power cord
7. Hand-foot switch
8. Foot pedal connector
9. Bur holder
10. Power lamp
11. Foot pedal
12. Motor connector
13. Handpiece (not included)
14. Handpiece holder
3 Installation 1. Before using the unit make sure that the Power switch (5) is in the "off" position.
2. Connect the handpiece to the Motor connector (12) on the Control box.
3. Set the Speed control dial (1) at "0".
4. Connect the Foot pedal (11) to the Foot pedal connector (8).
5. Then connect the device to the Powercord (6).
6. Unfasten the dust cover from the micro motor and put the handpiece (not included) on.
#174026 Contra angle dental handpiece or
#174027 Straight dental handpiece
7. Select bur (not included) and open the chuck by turning to counterclockwise. Place the bur in the open
chuck and lock it again by turning it clockwise. Check if the bur is fitted correctly and if the chuck is
securely locked.
8. Select the rotation by Forward-Reverse switch (3). (F = clockwise / R = counter clockwise)
9. Turn on the device with the Power switch (5).
10. Use the Speed control dial (1) to to set the required speed.
11. When using the Foot pedal connect it to the designated Foot pedal connector (8) on the back of the
Control box (2). The Power switch (5) must be in the "off" position. you can now set the desired rotation
speed.
12. IMPORTANT: Before changing the bur it is also necessary to switch the power off (5) or set the Speed
control dial (1) to "0". Please hold at least 2-3 mm distance between handpiece point and burs. Before
bur changing be sure to stop handpiece running. Otherwise the handpiece can be damaged.
Manual EICKEMEYER II dental polisher/ drill
3/6
4 Safety instructions 1. Never leave the unit unsupervised when there are children or persons inexperienced in using the unit
nearby.
2. Only use the unit for the applications described in these operating instructions. Only use bits and
accessories recommended by the manufacturer.
3. Never use the unit if the power cord is damaged or if the unit has been dropped or come in contact
with water.
4. Please follow the care instructions in the handpiece manual.
5. Do not clean or lubrify the handpieces during operation.
6. Switch off the unit before changing the rotation direction.
7. Use the folowing cutout for the Control box: 220V/250V/2A.
8. Switch off the unit before changing filling bits.
9. The bit has to rotate before it can be used on a tooth.
10. Wear protective goggles during operation and ensure an adadequate extraction of air.
11. When storing the unit, insert one bit into the chuck of the handpiece.
5 Operation Operating conditions:
Temperature: +10°C~+40°C
Humidity: 30%~75%
Air pressure: 700~1060 hPa
IMPORTANT NOTE:
Handpiece may only be used with included Foot pedal.
Damaged burs can cause early material fatigue.
6 Maintenance You have purchased a low-maintenance dental unit. Only the carbon brushes in the micro motor should
be changed once a year. Please send us your unit in.
It is crucial to thoroughly clean and lubrify the handpieces after each use!
(recommended spray: #174010 and adapter #17401150).
Before cleaning the micro motor please make sure to lock the micro motor with the locking screw
(included) in order to prevent liquids entering the micro motor!
After lubrication put the micro motor with
the head down into the mount
Manual EICKEMEYER II dental polisher/ drill
4/6
Lubrication of the Straight handpiece Demounting prior to and mounting after
lubrication of the Counter angle handpiece
(interior)
Lubrication of the Counter angle handpiece Lubrication of the Counter angle handpiece
(extraneous) (interior)
IMPORTANT NOTE: Please store the handpiece after lubrication separately!
7 Trouble shooting 1. Check that the unit is properly connected to the mains outlet.
2. Check that the hand unit is correctly connected to the main unit.
3. Check that the power switch is in the "on" position.
4. Should the problems persist, please contact your service partner right away.
5. Check if the carbon brushes are worn off and need to be changed (please see chapter Maintenance).
Manual EICKEMEYER II dental polisher/ drill
5/6
8 Contents EICKEMEYER II dental polisher/ drill _____________________________________________________________________ 1
1 General _____________________________________________________________________________________________ 2
2 Product description _________________________________________________________________________________ 2
3 Installation _________________________________________________________________________________________ 2
4 Safety instructions __________________________________________________________________________________ 3
5 Operation ___________________________________________________________________________________________ 3
6 Maintenance ________________________________________________________________________________________ 3
7 Trouble shooting ___________________________________________________________________________________ 4
8 Contents ____________________________________________________________________________________________ 5
9 Addresses___________________________________________________________________________________________ 6
GERMANY
EICKEMEYER KGEltastraße 878532 TuttlingenT +49 7461 96 580 0 F +49 7461 96 580 90E [email protected]
CANADA
EICKEMEYER Inc.250 Briarhill Dr.Stratford, Ont. CanadaN5A 7S2T +1 519 273 5558F +1 519 271 7114E [email protected] www.eickemeyerveterinary.com
DENMARK EICKEMEYER ApSLysbjergvej 6, Hammelev6500 Vojens T +45 7020 5019F +45 7353 5019E [email protected]
ITALY
EICKEMEYER S.R.L.Via G. Verdi, 8 65015 Montesilvano (PE)T +39 085 935 4078 F +39 085 935 9471E [email protected]
NETHERLANDS
EICKEMEYER B.V.Bedrijventerrein Pavijen-West Bellweg 444104 BJ CulemborgT +31 345 58 9400F +31 345 58 9401E [email protected]
POLAND
EICKEMEYER Sp. z o.o. Al. Jana Pawła II 27 00-867 Warszawa T +48 22 185 55 76 F +48 22 185 59 40 E [email protected]
SWITZERLAND
EICKEMEYER AGSandgrube 299050 Appenzell T +41 71 788 23 13 F +41 71 788 23 14E [email protected]
UNITED KINGDOM
EICKEMEYER Ltd.3 Windmill Business Village Brooklands CloseSunbury-on-Thames Surrey, TW16 7DYT +44 20 8891 2007F +44 20 8891 2686E [email protected]