Electric ActuatorITQ Series
BS EN ISO 9001:2000
INTRODUCTION
- I-Tork controls designs, produces and provides high quality actuators and services related to valve automation.
- Our long years experience in automation field enables us to launch ITQ series electric actuator which has compact size, robust construction, reliable performance and ability to integrate fully into sophisticated control systems.
- I-Tork controls is always ready to provide you with its ITQ series actuator and accessories, with quality service.
2
FEATURES
- Compact and robust construction, light weight providing high output torque (Max3000Nm).
- Wide range of torque variation (From min 100Nm to max 3000Nm).- Hard anodized aluminum housing inside and outside with external powder coated against severe industrial environment.
- Enclosure using radial seals & O-rings that provide protection to waterproof IP67 (Nema 4 & 6) and optional watertight IP68
- Mounting base according to ISO5211 standard.- Removable drive bushing for easy machining and mounting.- Self-locking provided by double worm gearing (no brake required).- Auto-declutching manual override handwheel with padlockable auto / manual switchable lever.
- Reliable Mechanical Torque sensing system providing safe operation in overload condition.
- Large size window and indicator provides better position indication from a distance.- Various Local position control options providing easy commissioning and operation in field.
- Digitalized control component.
3
Cable entries- Standard 2-PF3/4"(Max 1") for various cable gland.
External mechanicalstopper- Prevents over run of travel angle when limit switch fails.
Removable drive bushing and ISO5211 mounting base
- (F07~F16) for easy mounting on valve.
Optional long (Explosion proof)
Tapered interface between cover and lower housing- For easy lifting cover up from lower housing for wiring or maintenance.
- Standard: Short interface for providing easier access to internal component
- Explosion proof : Long interface for keeping the length of flame path
Standard short
② Gearing
- Precisely machined double worm gear c/w minimum back-lash, low noise, high output torque.
③ Self locking
- Provided by double worm gearing to keep position of valve unchanged against reverse torque from valve.
CONSTRUCTIONCONSTRUCTION
4
Captive cover bolts- Designed to prevent losing it during maintenance or installation.
* All external bolts are stainless steel for rust prevention.
① Housing
- Hard anodized Aluminum casting and external epoxy powder coated against severe industrial environment.
④ Sealing
- By O-ring in all interfaces IP67(standard), and double o-ring for IP68 (option)
⑤ Handwheel
- Different sizes depending on actuator torque, and knob on handwheel for easy operation.
⑥ Motor
- Specially designed induction motor to generate high starting torque and high efficiency equipped with thermal protector to prevent damage from over heating.
- Insulation class F
Indicator - Continuous mechanical position indicator and window with dial
Limit switches- Directly engaged with
driving shaft to set accurate position of valve.
- 2 ea for each travel end (open/close).
- Optional Extra Limit Switches (Max 4 ea for each end) : Except for ITQ0100
Torque switches - Protect actuator from damage caused by overload from the driven valve over the whole travel.
- 1 each for open / close
Space Heater- Anti-condensation
5
Terminal- Spring loaded push type terminal for tight wiring connection under severe vibration.
Manual override- Auto / Manual switchable lever and handwheel engagement for emergency manual operation.
- Drive force automatically resorted by motor start, unless lever padlocked to prevent this occuring.
TECHNICAL INFORMATION
STANDARD SPECIFICATION
Model
Rated torque (Nm)Duty cycle S4 (%)
Operating time (second) 50Hz 60Hz
Max bore Size (mm) Key( )
Square( )Rated current (A)
1Phase / 110V / 50Hz 60Hz
1Phase / 220V / 50Hz 60Hz
3Phase / 380V / 50Hz 60Hz
3Phase / 440V / 50Hz 60Hz
DC / 24VMotor insulation class
ISO 5211 mounting flangeWeight (Kgs)
No of handwheel turns
ITQ 0100
100 40
21 18
22 20
0.98 1.10 0.520.58 0.43 0.33 0.59 0.42 2.8F
F077
10
ITQ 0160
16030
26 22
25 23
1.60 1.70 0.85 0.900.300.300.300.324.0F
F07/F101512
ITQ 0240
24030
2622
25 23
1.62 1.72 0.87 0.90 0.32 0.32 0.32 0.35 5.0 F
F10/F1215 12
ITQ 0350
350 30
31 26
40 34
1.72 1.80 0.92 0.95 0.32 0.32 0.32 0.35 6.8F
F10/F1220 14
ITQ 0500
500 30
31 26
40 34
3.60 3.90 1.50 1.60 0.52 0.56 0.55 0.58
- F
F12/F1420 14
ITQ 0800
80030
3932
48 40
3.90 4.20 2.05 2.20 0.82 0.88 0.82 0.88
-F
F12/F1425 17
ITQ 1100
110030
39 32
48 40
3.90 4.30 2.15 2.30 0.84 0.90 0.840.88
- F
F12/1425 17
ITQ 1500
1500 30
93 78
75 64
3.60 3.90 1.50 1.60 0.52 0.56 0.55 0.58
- F
F16 65 65
ITQ 2000
200030
11797
75 64
3.80 4.20 2.05 2.20 0.82 0.88 0.82 0.88
-F
F16 75 70
ITQ 3000
300030
117 97
75 64
3.80 4.20 2.15 2.30 0.84 0.90 0.84 088
-F
F16 75 70
EnclosureMain Power supply
Control power supplyDuty cycle(on-off)
Duty cycle(modulating)Motor
Limit switchesTorque switches
Stall protection/ set temp.Travel angle
Position indicatorManual override
Self locking Mechanical stopper
Space HeaterCable entries
LubricationTerminal block
Ambient temperature
Ambient humidityAnti vibration
External coating
Weatherproof IP67, NEMA4 and 6, O-ring sealed 110/220VAC/1Ph/50/60Hz, 380/440/VAC/3Ph/50/60/Hz ±10%110/220VAC/1Ph/50/60Hz ±10%S2: 10Min~30Min / S4: 20~50% S4, 30~50%, 300~1200 start/HourSquirrel Caged induction motor2 each for Open and Close (SPDT 250VAC/10A rating) 1 each for Open and Close (SPDT 250VAC/10A rating except for ITQ 0100)Built in Thermal protection, Open 150oC±5oC, Close 97oC±15oC90o ± 5o (0o ~ 100o)Continuous mechanical indicator with arrowDe-clutchable Provided by double worm gearing (no brake)1 each for each travel end (Open and Close), external & adjustable 5W(110/220VAC) for anti-condensation2 - PF 3/4" TAP EP type greaseScrew and Lever Push type (spring loaded)Basic actuator : -20oC~+70oCc/w control options : -10oC~+60oC90%RH Max (Non-Condensing)XYZ 10g. 02~34Hz, 30 minutesDry powder (Polyester)
6
Mechanical
OPTION AVAILABILITY
Remote monitoring and control
Local control
Symbol
EXWTALSATSEXTSV
Remark
Approved by KTL10M Head 100hoursExcept for ITQ 0100Except for ITQ 0100Except for ITQ with Gear boxPlease consult before ordering
Description
Explosion proof (Ex d II B T4)Watertight (IP68), Temporary submersibleAuxiliary limit switches (Max 2 for each travel end)Auxiliary torque switches (Max 2 for each travel end)Extended travel angle (up to 120o, 135o, 180o, 270o, )Variation in torque and operating speed
PK
CT
RPC/ Signalconfiguration
Potentiometer kit (output signal : 0~1 Kohm)High resolution potentiometer and precisely machined gearing are directly engaged with drive shaft to feedback continuous position of valve
Current transmitter (output signal : 4-20mA)Zero / Span AdjustmentConvertable DIP Switch (4 wire to 2 wire)
Remote position controller (by input and output signal)Input : 4-20mA, 0-10VDC, 2~10VDC, 1~5VDC, 0~5VDCOutput : 4-20mA, 0-10VDC, 2~10VDC, 1~5VDC, 0~5VDCAuto-calibrationReverse operating direction
LP2 for 1 & 3 Phase (ITQ 0100~3000)
Control power : 110/220VAC, 24VDCMechanical selector switches - Local/Remote & Open/Stop/CloseLocal lamp indication - Remote - Yellow(on), Local-Red(on) Fully open- Green(on), Fully close-Red(on)* Options Available : PK, CT, RPC(Modulating), IP67, Explosion proof
LM2 for 3 phase(ITQ 0100~3000)
Mechanical selector switches - Local/Remote & Open/Stop/CloseLocal lamp indication - Remote - Yellow(on), Local-Red(on) Fully open- Green(on), Fully close-Red(on)Mechanical reversing magnetic contactors, control transformer(110/220VAC)Options available : PK, CT, RPC(Modulating), IP67, Explosion proof
PK
CT
RPC
7
LD1 for 3phase(Integral) (ITQ 0160~3000)
Magnetic selector switches - Local/Remote & Open/Stop/CloseLocal lamp indication - Fully close - Green(On), Closing - Green(Flickering) Torque switch trip - Yellow (on), Fault - Yellow (Flickering) Fully open - Red (on), Opening - Red (Flickering)Electronic reversing contactors, Transformer, Phase discriminator(Detection, Auto-Correction)24points terminal stripsRemote position indication : Position monitoring relaysOptions available : PK, CT, RPC(Modulating), Profibus communication, Local digital position indication(LCD): Either 4-20mA DC or % IP67, Explosion proof
LD2 for 3 phase(integral with IP68 enclosure) (ITQ 0160~3000)
Magnetic selector switches - Local/Remote & Open/Stop/CloseLocal lamp indication - Fully close - Green(On), Closing - Green(Flickering) Torque switch trip - Yellow (on), Fault - Yellow (Flickering) Fully open - Red (on), Opening - Red (Flickering)Reversing electronic contactors, Transformer, Phase discriminator(Detection, Auto-Correction)34points terminal strips,Separate compartment for terminal blockRemote position indication : Position monitoring relaysOptions available : PK, CT, RPC(Modulating), Profibus communication, Local digital position indication(LCD): Either 4-20mA DC or % IP67, Explosion proof
8
Local control
LP4 for 1 & 3 phase(ITQ 0160~3000)
Control power : 110/220VAC, 24VDCMagnetic selector switches - Local/Remote & Open/Stop/CloseLocal lamp indication - Fully close - Green(On), Closing - Green(Flickering) Torque switch trip - Yellow (on), Fault - Yellow (Flickering) Fully open - Red (on), Opening - Red (Flickering)Options available : PK, CT, RPC(Modulating), IP67, Explosion proof
Fail safe
BP for 1 Phase (ITQ 0100~0350)
Rechargeable Battery back up - Fail safe function When main AC power is alive, actuator works as normal on-off actuator.Once power is cut, actuator moves to pre-set fail safe position.Input power : 110/220VAC, 50/60HzOutput contacts : open/close/Alarm relayLED signal indication : 4 LEDs(Fully open/Close, Over torque and power status)Rechargeable battery : 2.0AH 27.5VDC(Ni-Cd)
Dimensions
(mm) (mm)
BASIC ACTUATOR DIMENSIONS
With Gear BoxType
FlangeISO5211
C
AB
D(Key)D(Squ.)
EFGHSXYZ
ITQ 0100
F07
70
M814222050 88 3
37 100 258 172 220
ITQ 0160
F07F10 70
102 M8/M10 14/17
25 23
58.5 125
3 57 115 338 229 259
ITQ 0240
F07 F10 70
102 M8/M10 14/17
25 23
58.5 125
3 57 115 338 229 259
ITQ 0350
F10 F12 102 125
M10/M12 17/21
40 34 80
148 3
62 145 357 244 288
ITQ 0500
F10 F12 102 125
M10/M12 17/21
40 34 80
148 3
62 145 357 244 288
ITQ 0800
F12 F14 125 140
M12/M16 20/25
48 40 95
178 3
67 170 380 287 313
ITQ 1100
F12 F14 125 140
M12/M16 20/25
48 40 95
178 3
67 170 380 287 313
ITQ 1500
F16
165
M20 32 75 64
135 245
5 90
145 368 293 506
ITQ 2000
F16
165
M20 32 75 64
135 245
5 90
170 380 312 531
ITQ 3000
F16
165
M20 32 75 64
135 245
5 90
170380 312 531
9
10
CONTROL OPTION DIMENSIONS(mm)
Type
ITQ 0100
ITQ 0160/0240
ITQ 0350
ITQ 0500
ITQ 0800/1100
ITQ 1500
ITQ 2000/3000
RPCX Y Z
340 190 220
O
O
O
O
O
O
CTX Y Z
316 172 220
O
O
O
O
O
O
BPX Y Z
428 172 220
508 229 259
527 244 288
X
X
X
X
LP2/LM2X Y Z
428 172 220
508 229 259
527 244 288
527 244 288
550 284 313
538 293 506
550 312 531
LP4/LD1X Y Z
419 172 220
499 229 259
518 244 288
518 244 288
541 284 313
529 293 506
541 312 531
LD2X Y Z
X
517 284 259
536 284 288
536 284 288
559 284 313
547 284 506
559 284 531
CHAR
GE
POW
ERCL
OSE
OPE
N
5050
OPEN100 7575
25
CLO
SE0
25
5050
CLOSE
025
25
7575 100OPEN
X
Y
RE
RE
LO
LO
STCL
CL
OP
OP
25
25
100OPEN
0CLO
SE25
75
50
CLO
SE25
50
75
0
100OPEN
755050
75
X
Y
CLO
SE
CLOSE
OPEN100 75
25
5075
25
50
OPEN100 75
025
50
75
25
50
0
X
Y
STATUS
REMOTE
POWER
100%
OPEN
OK
FAULTCLOSE
OPE LOC
CLOSTOP REM
25
25
50
100OPEN
50
7575
250
CLOSE
50
10050
7575
250
CLO
SE
OPEN
X
Y
STATUS
REMOTE
POWER
100%
OPEN
OK
FAULTCLOSE
OPE LOC
CLOSTOP REM
50
OPEN7575 100
50
25
CLO
SE25
0
7575
5050
CLOSE
250
25
100OPEN
X
Y
CLO
SE 25
25 CLOSE
5050
OPEN10075 75
250
75 7550
0
50
25
100
OPEN
XY
* O : Installed inside of actuator * X : Not available
* Z : Height of basic actuator
ITQ 0100
RPC
LP2/LM2
BP
LP4/LD1
LD2
CTITQ 0100~3000
11
ALS : Auxiliary Limit switchAOLS : Auxiliary Open Limit switch (Dry contact)ACLS : Auxiliary Close Limit switch (Dry contact)O : Open lampC : Close lampOT : Over torque lampCLS : Close limit switch (250VAC 10A)OLS : Open limit switch (250VAC 10A)CTS : Close torque switch (250VAC 10A)OTS : Open torque switch (250VAC 10A)CC : Close magnetic coilOC : Open magnetic coilM : MotorTP : Thermal protector (250VAC 15A option)MTP : Thermal protector built in motor* Each actuator should be powered through its own
individual switch or relay contacts to prevent cross feed between two or more actuators.
* In case of 3ph actuator, make sure to place actuator on the middle of travel angle before electrical operation to avoid "Jamming"
* All internal wiring is done as color coding.
TYPICAL WIRING (ITQ 0100)
110/220VAC/50/60Hz, 1Ph(On-Off) 110/220VAC/50/60Hz, 1Ph(Modulating : RPC)
380/440VAC/50/60Hz, 3Ph(On-Off)
WHI
BLU
OPEN
G/F
5W
SUGGESTED CUSTOMER'S WIRING
ACTUATOR WIRING
GR
E
RE
D
BLU
CONDENSER
MTP
RE
D
BLU
1COM
3NO
G/F
BRO
WH
I
2NC
HEATER
RE
D
BLA WH
I
TP
STOPCLOSE
NE
UTR
AL
LIV
E
EARTHBASE
NC NO
COM1
BLU
GR
E
2 3NC NO
1
COM1
RED
3NO
2NC
COM
GR
E
PU
R
2 3
CLOSELAMPLAMP
OPEN
PU
R
OLS
M
INCOMING POWERAC 1PH ( V)
42 3
CLS
765
AOLS
1211
ACLS
98
COAUX. CONTACT
MAX. 250VAC 10A
10
FEED BACKPOTENTIOMETER EARTH
BASE
OPEN
LIV
E
NE
UTR
AL
BLU
RE
D
MTP
CONDENSER
BLA
COM COM11
HEATER
2 323NC NONCNO
G/F
5W
WH
I
PROPOSE CUSTOMER'S WIRINGACTUATOR WIRING
BLURED
LAMPCLOSE OPEN
LAMP
WHI
PU
R
GR
E
TP
BRO
WH
I
1
STOPS/W
WHI
BLA 0V
110/220V
CLOSEOPEN COM. COM.
RED
BLU
OR
A
IN
VR1
BLA
STOP CLOSE
GR
Y
BLA
WH
I
BLU
RE
D
G/F
WH
I
32
PU
R
GR
Y
OUT
VR2 VR3
PU
R
GR
E
BLU
NC
RED
1COM
NO32
NC2
1COM
3NO
INDICATORPOSITION
REMOTE POSITION CONTROLLER(RPC)
-
INCOMING POWERAC 1PH ( V)
MCLS OLS
OC
2 31
RPC CARD
-+
4
++ -
SIGNAL
8765 11109
AM INPUT
-+
ACLS AOLS
12
MAX. 250VAC 10AAUX. CONTACT
13 14
EARTHBASE
CLOSE
MTPMTP COM
NC
HEATER
2G/F
WH
I
5W
COM1
NO32
NC
1
NO3
BR
O
WH
I
RE
D
BLU
GR
E
PU
R
WH
I
BLA
RE
D
BLU
TP
LAMPOPENCLOSE
LAMP
LIV
E
NE
UTR
AL
CCOC
CC53 1 3
64264OC51
2
PROPOSE CUSTOMER'S WIRINGACTUATOR WIRING
OPEN STOP
32 2 3NC
RED
1COM
NONC
1COM
NO
G/F
PU
R
GR
E
BLU
11
UAC 3PH ( V)
WV
MAIN POWER
MCLS OLS
C
83 4 5 62
CC
7
AC 1PH ( V)
OC O
9 101
CONTROL POWER
ACLS AOLS
12 13
MAX. 250VAC 10AAUX. CONTACT
14
Dimensions
12
SWITCH
CLS 1-2
CLS 1-3
OLS 1-2
OLS 1-3
CTS 1-3
OTS 1-3
TORQUE AND LIMIT SWITCHES OPERATION
CLOSE
* CLOSING TORQUE SWITCH INTERRUPTS CONTROL IF
MECHANICAL OVERLOAD OCCURS DURING CLOSING CYCLE
* OPENING TORQUE SWITCH INTERRUPTS CONTROL IF
MECHANICAL OVERLOAD OCCURS DURING OPENING CYCLE
INTERMEDIATE OPEN
380/440VAC/50/60Hz, 3Ph(On-Off)
110/220VAC/50/60Hz, 1Ph(Modulating : RPC) 110/220VAC/50/60Hz, 1Ph(On-Off)
TYPICAL WIRING (ITQ 0160~ITQ 3000)
NO
COM
COM
NO
RE
D
BLA
WH
I
RE
D
GR
E
BLU
TP2NC
MTP
BLU
CONDENSER
RE
D
EARTHBASE
HEATER5W
1
1
WH
IG
/F
BR
O
NC2
ACTUATOR WIRING
LIV
E
NE
UTR
AL
BLA
RED
PROPOSE CUSTOMER'S WIRING
BLU
GR
E
PU
R
YE
LY
EL
BLU
BLU
BLA
G/F
RE
D
WH
I
BLA
GR
Y
323NONC
WHIBLA
110/220V
0V
INBLU
RED
COM.COM.OPEN CLOSE
1COM
WH
I
1COM
NC NO2 33
LAMPCLOSEOVER
TORQUELAMP
OPENLAMP OPEN
BLU
STOP
CLOSE
S/W
STOP
RE
D
GR
E
BLU
PU
R
WH
I
NC2 3
NONO3
1COM
NC2
3
GR
Y
FEED BACK
VR3
21
PU
R
OR
A
VR1 VR2
OUT
POTENTIOMETER
1COM
REMOTE POSITION CONTROLLER(RPC)
INDICATORPOSITION
AC 1PH ( V)INCOMING POWER
MCLS
CTS
65432
+
RPC CARD
OLS
OTS
10 117 8 9
OOT C
141312 171615
M A
+ - +
SIGNALINPUT
AOLSACLS
- + -
20 21 2218 19
-
MAX. 250VAC 10AAUX. CONTACT
BASEEARTH
NO
COM
COM
NO
GR
E
BLA
RE
D
RE
D
BLU
WH
I
HEATER5W
NC2
1
1
2NC
BR
O
G/F
WH
I
TP
RE
D
BLU
YE
L
BLU
GR
E
PU
R
G/F
YE
L
BLU
COM1
NO32
NC3
WH
I
3NC2 3
NO
COM1
BLU
GR
E
RE
D
PU
R
NC2 3
NO
COM1
NO32
NC
COM1
MTPMTP
PROPOSE CUSTOMER'S WIRINGACTUATOR WIRING
1
2
LIV
E
NE
UTR
AL
CCOC
CC53 1 3
64264OC5
CLOSESTOPOPENLAMPCLOSEOVER
TORQUELAMP
OPENLAMP
CONTROL POWERAC 1PH ( V)
OC
U
AC 3PH ( V)MAIN POWER
CC
WV
COT O
M
9874 5 62 3 15 16 1711 12 13 1410
ACLS AOLS
AUX. CONTACTMAX. 250VAC 10A
CTS
CLS
OTS
OLS
LAMPCLOSE
BLU
NO32
NC
1COM
WH
I
1COM
NC NO2 3
BLA
3NONC
2TP
1COM
1
WH
IG
/F
BR
O
COM
NONC32
YE
LY
EL
RE
D
GR
E
BLU
BLU
RE
D
BLU
WH
I
BLA
CONDENSER
RE
D
MTP
HEATER5W
ACTUATOR WIRINGPROPOSE CUSTOMER'S WIRING
LIV
E
NE
UTR
AL
REDBLU
OVERTORQUELAMP
G/F
RE
D
BLU
GR
E
PU
R
PU
R
RE
D
GR
E
BLU
1COM
NO32
NC
EARTHBASE
1COM
NC2 3
NO
STOPOPEN CLOSEOPENLAMP
2
AC 1PH ( V)INCOMING POWER
OT
6543 7 8
M OLS
OTS
CLS
CTS ACLS AOLS
MAX. 250VAC 10AAUX. CONTACT
1514
OC
131210 119 1716
13
TYPICAL WIRING (LD2 for 3phase)
T.H
PCB CON1TO TERMINAL
MTH
MTH
OPE LOC
CLOSTOP REM
DC24V OUTPUT COMMON
RELAY
OVER-TORQUERELAY
MONITOR
RELAY
OPENINGRELAY
CLOSING
F1DC24V OUTPUT
TERMINAL PCB
AOLS
ACLS
OTS
SW2 : OFF=T.H BYPASS AT ESDSW2 : ON =T.H UNBYPASS AT ESDSW3 : OFF=ESD DIR = CLOSE
SW3 : ON = ESD DIR = OPEN
SW4 : ON = LOCAL SW = INCHING SW4 : OFF=LOCAL SW = HOLDING
LIMIT SWITCHES
OLS
CTS
CLS
S.H
C.R : CLOSE RELAYO.R : OPEN RELAY
OLS : OPEN LIMIT SWITCH
S.H : SPACE HEATERACLS : AUX. CLOSE LIMIT SWITCHAOLS : AUX. OPEN LIMIT SWITCHCLS : CLOSE LIMIT SWITCH
PROTECTOR
CTS : CLOSE TORQUE SWITCHOTS : OPEN TORQUE SWITCH
SW1 : ON = INCORRECT PHASE
T.H : THERMOSTAT(OPTION)
LOCAL-STOP-REMOTE
SW1 : OFF=PHASE DISCRIMINATOR
MTH : MOTOR THERMOSTAT(STANDARD)
CLOSE-OPEN
COMMENT
CUSTOMER SUPPLY
AC V 3 HzPOWER SOURCE
SW1SW2SW3SW4
DIS
CR
IMIN
ATO
RP
HA
SE
SETTING SW
DC 5V
POWER TRANSFORMER
F1
SUPPLYDC 24V
SUPPLY
ACTUATOR ASS'Y(I-TORK SUPPLY)
LOCAL CONTROL PCB
O.R
MAIN PCBC.R
STATUS
REMOTE
CLOSEPOWER
OK
100%
FAULT OPEN
CON3
CON11
CON2
CON3
CON4
CON5
CON12
CON1
CON5
CON1
CON2
CON2
LIM
IT S
WIT
CH
ES
OP
ER
ATI
ON
1-3
OLS(
AOLS
)
CLS(
ACLS
) 1-2
1-3
1-2
OLS(
AOLS
)
CLS(
ACLS
)S
WIT
CH
ES
OPEN
CLOS
EIN
TERM
EDIA
TE
CLOSING RELAY NO
FULL CLOSED AUX. SWITCH COM.
FULL CLOSED AUX. SWITCH NC
FULL CLOSED AUX. SWITCH NO
FULL OPEN AUX. SWITCH COM.
FULL OPEN AUX. SWITCH NC
OPENING RELAY COM.
CLOSING RELAY COM.
OPENING RELAY NO
FULL OPEN AUX. SWITCH NO
12
16
17
18
11
13
19
14
27
15
OVER TORQUE RELAY COM.
MONITOR RELAY COM.
OVER TORQUE RELAY NO
MONITOR RELAY NC
MONITOR RELAY NO
23
26
25
22
24
TSR
ST
R M
STOP
21
20
34
30
28
OPEN
CLOSE
E.S.D
31
32
33
29
ITQ Electric Actuator Standard selection guide for valves
* The above table is just reference without I-TORK's responsibility.
* Actuator sizing must be done based on actual valve torque.
ITQ 0100
ITQ 0160
ITQ 0240
ITQ 0350
ITQ 0500
ITQ 0800
ITQ 1100
ITQ 1500
ITQ 2000
ITQ 3000
Butterfly valve 10KANSI 150#
100A (4")
125 (5")
150A (6")
200A (8")
250A (12")
350A (14")
400A (16")
450A (18")
500A (20")
600A (24")
2-Way Ball valve 10KANSI 150#
50A(2")
65 / 80A(2 1/2" / 3")
100A (4")
150A (6")
200A (8")
250A (10")
300 / 350A(12" / 14")
3-Way Ball valve 10KANSI 150#
40A (1 1/2")
50A (2")
65 / 80A(2 1/2" / 3")
100A (4")
125A (5")
150A (6")
200A (8")
250 / 300A(10" / 12")
Valve
Actuator
ITQ ELECTRIC ACTUATOR
ITQ-CA-05/09
* The details of this catalog are subject to change without prior notification.