90
Chapter : 1 WIRING (WG) Mains (MA) Item No Short Description Unit Material Labour Total 1.1 Concealing of Conduits (WG-MA/CC) 1-1-1 Chiselling wall/floor appropriately and with supplying & laying ISI mark Rigid Steel conduit 16 SWG 20 mm dia. with necessary accessories as per specification No: WG-MA/CC, para no. 1.2.3 Mtr. 105 35.89 141.00 1-1-2 Supplying & laying ISI mark Rigid Steel conduit 16 SWG - 20 mm. dia. with necessary accessories as per specification No: WG-MA/CC, para no. 1.2.3 Mtr. 105 29.56 135.00 1-1-3 Chiselling wall/floor appropriately and with supplying & laying ISI mark Rigid Steel conduit 16 SWG 25 mm dia. with necessary accessories as per specification No: WG-MA/CC, para no. 1.2.3 Mtr. 124 35.89 160.00 1-1-4 Supplying & laying ISI mark Rigid Steel conduit 16 SWG - 25 mm. dia. with necessary accessories as per specification No: WG-MA/CC, para no. 1.2.3 Mtr. 124 31.67 156.00 1-1-5 Chiselling wall/floor appropriately and with supplying & laying ISI mark Rigid Steel conduit 16 SWG 32 mm dia. with necessary accessories as per specification No: WG-MA/CC, para no. 1.2.3 Mtr. 169 44.34 213.00 1-1-6 Supplying & laying ISI mark Rigid Steel conduit 16 SWG - 32 mm. dia. with necessary accessories as per specification No: WG-MA/CC, para no. 1.2.3 Mtr. 169 33.78 203.00 1-1-7 Chiselling wall/floor appropriately and with supplying & laying I.S.I. Mark Rigid P.V.C. conduit 20 mm. dia. with necessary accessories as per specification No: WG- MA/CC, para no. 1.2.1 Mtr. 69 35.89 105.00 1-1-8 Chiselling wall/floor appropriately and with supplying & laying I.S.I. Mark Rigid P.V.C. conduit 25 mm. dia. with necessary accessories as per specification No: WG- MA/CC, para no. 1.2.1 Mtr. 80 40.12 120.00 1-1-9 Chiselling wall/floor appropriately and with supplying & laying I.S.I. mark Rigid P.V.C. conduit 32 mm. dia. with necessary accessories as per specification No: WG- MA/CC, para no. 1.2.1 Mtr. 98 44.34 142.00 Note :- 1) For concealed wiring stranded copper wires shall be invariably used. 2) Add Rs 3/- per meter for erecting conduit on stone wall 1.2 PVC Flexible/Rigid Conduits/Casing-n-capping (WG-MA/CON) 1-2-1 Supplying and laying P.V.C. corrugated flexible conduit 16 mm in dia. conforming to I.S. and approved make with required number of couplings, PVC bushes, check nuts etc. complete. Mtr. 10 5.28 15.00 1-2-2 Supplying and laying P.V.C. corrugated flexible conduit 20 mm in dia. conforming to I.S. and approved make with required number of couplings, PVC bushes, check nuts etc. complete. Mtr. 13 5.28 18.00 1-2-3 Supplying and laying P.V.C. corrugated flexible conduit 25 mm in dia. conforming to I.S. and approved make with required number of couplings, PVC bushes, check nuts etc. complete. Mtr. 17 5.28 22.00 1-2-4 Supplying and laying P.V.C. corrugated flexible conduit 32 mm in dia. conforming to I.S. and approved make with required number of couplings, PVC bushes, check nuts etc. complete. Mtr. 24 5.28 29.00 1-2-5 Supplying and laying P.V.C. corrugated flexible conduit 40 mm in dia. conforming to I.S. and approved make with required number of couplings, PVC bushes, check nuts etc. complete. Mtr. 37 5.28 42.00 1-2-6 Supplying and laying P.V.C. corrugated flexible conduit 50 mm in dia. conforming to I.S. and approved make with required number of couplings, PVC bushes, check nuts etc. complete. Mtr. 50 5.28 55.00 1-2-7 Supplying and laying rigid PVC conduit 20 mm dia. with PVC accessories on wall/ceiling as per specification No: WG-MA/CON, para no. 1.1.1 Mtr. 48 8.45 56.00 1-2-8 Supplying and laying rigid PVC conduit 25 mm dia. with PVC accessories on wall/ceiling as per specification No: WG-MA/CON, para no. 1.1.1 Mtr. 64 8.45 72.00 1-2-9 Supplying and laying rigid PVC conduit 32 mm dia. with PVC accessories on wall/ceiling as per specification No: WG-MA/CON, para no. 1.1.1 Mtr. 88 8.45 96.00 1-2-10 Supplying and laying PVC trunking (PVC casing-n-capping) of size 20 mm. with accessories on wall/ceiling as per specification No: WG-MA/CON, para no. 1.1.2 Mtr. 20 13.72 34.00 1-2-11 Supplying and laying PVC trunking (PVC casing-n-capping) of size 25 mm. with accessories on wall/ceiling as per specification No: WG- MA/CON, para no. 1.1.2 Mtr. 24 13.72 38.00 1-2-12 Supplying and laying PVC trunking (PVC casing-n-capping) of size 32 mm. with accessories on wall/ceiling as per specification No: WG-MA/CON, para no. 1.1.2 Mtr. 31 13.72 45.00 1-2-13 Supplying and laying PVC trunking (PVC casing-n-capping) of size 40 mm. with accessories on wall/ceiling as per specification No: WG- MA/CON, para no. 1.1.2 Mtr. 49 13.72 63.00 1-2-14 Supplying and laying PVC box trunking of size 50x16 mm. With accessories on wall/ceiling as per specification No: WG-MA/BOX, para no.1.1.2 Mtr. 67 13.72 81.00 1-2-15 Supplying and laying PVC box trunking of size 50x50 mm. With accessories on wall/ceiling as per specification No: WG-MA/BOX, para no. 1.1.2 Mtr. 128 13.72 142.00 1-2-16 Supplying and laying PVC box trunking of size 75x50 mm. With accessories on wall/ceiling as per specification No: WG-MA/BOX, para no. 1.1.2 Mtr. 290 13.72 304.00

Electrical CSR 12-13

Embed Size (px)

DESCRIPTION

Electrical CSR 12-13

Citation preview

Page 1: Electrical CSR 12-13

Chapter : 1 WIRING (WG)Mains (MA)

Item No Short Description Unit Material Labour Total

1.1 Concealing of Conduits (WG-MA/CC) 1-1-1 Chiselling wall/floor appropriately and with supplying & laying ISI mark Rigid Steel

conduit 16 SWG 20 mm dia. with necessary accessories as per specification No: WG-MA/CC, para no. 1.2.3

Mtr. 105 35.89 141.00

1-1-2 Supplying & laying ISI mark Rigid Steel conduit 16 SWG - 20 mm. dia. with necessary accessories as per specification No: WG-MA/CC, para no. 1.2.3

Mtr. 105 29.56 135.00

1-1-3 Chiselling wall/floor appropriately and with supplying & laying ISI mark Rigid Steel conduit 16 SWG 25 mm dia. with necessary accessories as per specification No: WG-MA/CC, para no. 1.2.3

Mtr. 124 35.89 160.00

1-1-4 Supplying & laying ISI mark Rigid Steel conduit 16 SWG - 25 mm. dia. with necessary accessories as per specification No: WG-MA/CC, para no. 1.2.3

Mtr. 124 31.67 156.00

1-1-5 Chiselling wall/floor appropriately and with supplying & laying ISI mark Rigid Steel conduit 16 SWG 32 mm dia. with necessary accessories as per specification No: WG-MA/CC, para no. 1.2.3

Mtr. 169 44.34 213.00

1-1-6 Supplying & laying ISI mark Rigid Steel conduit 16 SWG - 32 mm. dia. with necessary accessories as per specification No: WG-MA/CC, para no. 1.2.3

Mtr. 169 33.78 203.00

1-1-7 Chiselling wall/floor appropriately and with supplying & laying I.S.I. Mark Rigid P.V.C. conduit 20 mm. dia. with necessary accessories as per specification No: WG-MA/CC, para no. 1.2.1

Mtr. 69 35.89 105.00

1-1-8 Chiselling wall/floor appropriately and with supplying & laying I.S.I. Mark Rigid P.V.C. conduit 25 mm. dia. with necessary accessories as per specification No: WG-MA/CC, para no. 1.2.1

Mtr. 80 40.12 120.00

1-1-9 Chiselling wall/floor appropriately and with supplying & laying I.S.I. mark Rigid P.V.C. conduit 32 mm. dia. with necessary accessories as per specification No: WG-MA/CC, para no. 1.2.1

Mtr. 98 44.34 142.00

Note :- 1) For concealed wiring stranded copper wires shall be invariably used. 2) Add Rs 3/- per meter for erecting conduit on stone wall

1.2 PVC Flexible/Rigid Conduits/Casing-n-capping (WG-MA/CON)

1-2-1 Supplying and laying P.V.C. corrugated flexible conduit 16 mm in dia. conforming to I.S. and approved make with required number of couplings, PVC bushes, check nuts etc. complete.

Mtr. 10 5.28 15.00

1-2-2 Supplying and laying P.V.C. corrugated flexible conduit 20 mm in dia. conforming to I.S. and approved make with required number of couplings, PVC bushes, check nuts etc. complete.

Mtr. 13 5.28 18.00

1-2-3 Supplying and laying P.V.C. corrugated flexible conduit 25 mm in dia. conforming to I.S. and approved make with required number of couplings, PVC bushes, check nuts etc. complete.

Mtr. 17 5.28 22.00

1-2-4 Supplying and laying P.V.C. corrugated flexible conduit 32 mm in dia. conforming to I.S. and approved make with required number of couplings, PVC bushes, check nuts etc. complete.

Mtr. 24 5.28 29.00

1-2-5 Supplying and laying P.V.C. corrugated flexible conduit 40 mm in dia. conforming to I.S. and approved make with required number of couplings, PVC bushes, check nuts etc. complete.

Mtr. 37 5.28 42.00

1-2-6 Supplying and laying P.V.C. corrugated flexible conduit 50 mm in dia. conforming to I.S. and approved make with required number of couplings, PVC bushes, check nuts etc. complete.

Mtr. 50 5.28 55.00

1-2-7 Supplying and laying rigid PVC conduit 20 mm dia. with PVC accessories on wall/ceiling as per specification No: WG-MA/CON, para no. 1.1.1

Mtr. 48 8.45 56.00

1-2-8 Supplying and laying rigid PVC conduit 25 mm dia. with PVC accessories on wall/ceiling as per specification No: WG-MA/CON, para no. 1.1.1

Mtr. 64 8.45 72.00

1-2-9 Supplying and laying rigid PVC conduit 32 mm dia. with PVC accessories on wall/ceiling as per specification No: WG-MA/CON, para no. 1.1.1

Mtr. 88 8.45 96.00

1-2-10 Supplying and laying PVC trunking (PVC casing-n-capping) of size 20 mm. with accessories on wall/ceiling as per specification No: WG-MA/CON, para no. 1.1.2

Mtr. 20 13.72 34.00

1-2-11 Supplying and laying PVC trunking (PVC casing-n-capping) of size 25 mm. with accessories on wall/ceiling as per specification No: WG- MA/CON, para no. 1.1.2

Mtr. 24 13.72 38.00

1-2-12 Supplying and laying PVC trunking (PVC casing-n-capping) of size 32 mm. with accessories on wall/ceiling as per specification No: WG-MA/CON, para no. 1.1.2

Mtr. 31 13.72 45.00

1-2-13 Supplying and laying PVC trunking (PVC casing-n-capping) of size 40 mm. with accessories on wall/ceiling as per specification No: WG- MA/CON, para no. 1.1.2

Mtr. 49 13.72 63.00

1-2-14 Supplying and laying PVC box trunking of size 50x16 mm. With accessories on wall/ceiling as per specification No: WG-MA/BOX, para no.1.1.2

Mtr. 67 13.72 81.00

1-2-15 Supplying and laying PVC box trunking of size 50x50 mm. With accessories on wall/ceiling as per specification No: WG-MA/BOX, para no. 1.1.2

Mtr. 128 13.72 142.00

1-2-16 Supplying and laying PVC box trunking of size 75x50 mm. With accessories on wall/ceiling as per specification No: WG-MA/BOX, para no. 1.1.2

Mtr. 290 13.72 304.00

Page 2: Electrical CSR 12-13

1-2-17 Supplying and laying PVC box trunking of size 75x75 mm. With accessories on wall/ceiling as per specification No: WG-MA/BOX, para no.1.1.2

Mtr. 358 13.72 372.00

1-2-18 Supplying and laying PVC box trunking of size 100x50 mm. With accessories on wall/ceiling as per specification No: WG-MA/BOX para no. 1.1.2

Mtr. 459 13.72 473.00

1-2-19 Supplying and laying PVC slotted box trunking of size 25x25 mm. with accessories on wall/ceiling as per specification No: WG-MA/SLBOX, para no. 1.1.2

Mtr. 56 13.72 70.00

1-2-20 Supplying and laying PVC slotted box trunking of size 45x30 mm. with accessories on wall/ceiling as per specification No: WG-MA/SLBOX, para no. 1.1.2

Mtr. 91 13.72 105.00

1-2-21 Supplying and laying PVC slotted box trunking of size 60x45 mm. with accessories on wall/ceiling as per specification No: WG-MA/SLBOX, para no. 1.1.2

Mtr. 137 13.72 151.00

1-2-22 Supplying and laying PVC slotted box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification No: WG-MA/SLBOX, para no. 1.1.2

Mtr. 221 13.72 235.00

1-2-23 Supplying and laying PVC slotted box trunking of size 100x100 mm. with accessories on wall/ceiling as per specification No: WG-MA/SLBOX, para no. 1.1.2

Mtr. 486 13.72 500.00

Note :- Add Rs 3/- per meter for erecting conduit on stone wall

1.3 Bunch of Wires (WG-MA/BW) 1-3-1 Supplying & erecting mains with 2x1.5 sq.mm F.R solid copper PVC insulated wire

laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 26 6.33 32.00

1-3-2 Supplying & erecting mains with 2x1.5 sq.mm F.R.L.S solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 28 6.33 34.00

1-3-3 Supplying & erecting mains with 2x2.5 sq.mm F.R stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

Mtr. 39 10.56 50.00

1-3-4 Supplying & erecting mains with 2x2.5 sq.mm F.R.L.S stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

Mtr. 44 10.56 55.00

1-3-5 Supplying & erecting mains with 2x4 sq.mm F.R stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 60 10.56 71.00

1-3-6 Supplying & erecting mains with 2x4 sq.mm F.R.L.S stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

Mtr. 65 10.56 76.00

1-3-7 Supplying & erecting mains with 2x6 sq.mm F.R stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 91 10.56 102.00

1-3-8 Supplying & erecting mains with 2x6 sq.mm F.R L.S stranded/solid copper PVC insulated wire laid in provided conduit/trunking/insid pole/Bus bars or any other places. as per specification No: WG-MA/BW

Mtr. 101 10.56 112.00

1-3-9 Supplying & erecting mains with 2x10 sq.mm F.R stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 160 14.78 175.00

1-3-10 Supplying & erecting mains with 2x10 sq.mm F.R.L.S stranded/solid copper PVC insulated wire laid in provided conduit / trunking / inside pole / Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 181 14.78 196.00

1-3-11 Supplying & erecting mains with 3x2.5 Sq.mm F.R stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 61 13.72 75.00

1-3-12 Supplying & erecting mains with 3x2.5 sq.mm F.R L.S stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 65 13.72 79.00

1-3-13 Supplying & erecting mains with 3x4 sq.mm F.R stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 91 13.72 105.00

1-3-14 Supplying & erecting mains with 3x4 sq.mm F.R L.S stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 100 13.72 114.00

1-3-15 Supplying & erecting mains with 3x6 sq.mm F.R stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars orany other places as per specification No: WG-MA/BW

Mtr. 138 17.95 156.00

1-3-16 Supplying & erecting mains with 3x6 sq.mm F.R.L.S stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 151 17.95 169.00

1-3-17 Supplying & erecting mains with 3x10 sq.mm F.R stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 242 22.17 264.00

1-3-18 Supplying & erecting mains with 3x10 sq.mm F.R.L.S stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 272 22.17 294.00

Page 3: Electrical CSR 12-13

1-3-19 Supplying & erecting mains with 4x16 sq.mm F.R stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 514 25.34 539.00

1-3-20 Supplying & erecting mains with 4x16 sq.mm F.R L.S stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 562 25.34 587.00

1-3-21 Supplying & erecting mains with 4x25 sq.mm F.R stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 766 30.62 797.00

1-3-22 Supplying & erecting mains with 4x25 sq.mm F.R.L.S stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 890 30.62 921.00

1-3-23 Supplying & erecting mains with 4x35 sq.mm F.R stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 1100 30.62 1131.00

1-3-24 Supplying & erecting mains with 4x35 sq.mm F.R L.S stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 1137 30.62 1168.00

1-3-25 (New)

Supplying & erecting mains with 4x50 sq.mm FR stranded/solid copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Mtr. 1410 30.62 1441.00

Note :- 1) Double the rate of two wire bunch for calculating rate of four wire bunch up to 10 sq mm2) Continuous running earth wire should be provided of min. 1.5 sq. mm. up to phase wire of 2.5 sq. mm. And further earth wire of half of the size of phase wire is to be used only for light & power load .For Computer wiring size of earth wire shall be of same size as that of phase wire. 3) Rates for the earth wire shall be calculated as one half rate of mains of bunch of two wire and earth wire should be with green colour PVC. 4) For all types of wiring stranded copper wires shall be invariably used.

1.4 Mains on GI Bare Wire 1-4-1 Supplying and erecting mains with ISI mark 2 x 2.5 sq. mm. 1100 V. Grade

aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire.

Mtr. 25 9.5 35.00

1-4-2 Supplying and erecting mains with ISI mark 2 x 4 sq. mm. 1100 V. Grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire.

Mtr. 31 9.5 41.00

1-4-3 Supplying and erecting mains with ISI mark 2 x 6 sq. mm. 1100 V. Grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire.

Mtr. 39 9.5 49.00

1-4-4 Supplying and erecting mains with ISI mark 3 x 4 sq. mm. 1100 V. Grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire.

Mtr. 40 13.72 54.00

1-4-5 Supplying and erecting mains with ISI mark 3 x 6 sq. mm. 1100 V. Grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire.

Mtr. 52 13.72 66.00

1-4-6 Supplying and erecting mains with ISI mark 4 x 4 sq. mm. 1100 V. Grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire.

Mtr. 489 15.84 505.00

1-4-7 Supplying and erecting mains with ISI mark 4 x 6 sq. mm. 1100 V. Grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire.

Mtr. 63 25.34 88.00

1.5 Mains in Metal Conduit (WG-MA/MC) 1-5-1 Supplying & erecting mains with 2x1.5 sq.mm. F.R. copper wire, in 16gauge 20 mm

dia. Rigid Steel conduit with continuous GI earth wire of1.5 sq.mm. as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 131 33.78 165.00

1-5-2 Supplying & erecting mains with 2x1.5 sq.mm. F.R.LS copper wire, in 16gauge 20 mm dia. Rigid Steel conduit with continuous GI earth wire of 1.5 sq.mm. as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 132 33.78 166.00

1-5-3 Supplying & erecting mains with 2x2.5 sq.mm. F.R. copper wire, in 16gauge 20 mm dia.Rigid Steel conduit, with continuous GI earth wire of 1.5sq.mm. as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 145 39.06 184.00

1-5-4 Supplying & erecting mains with 2x2.5 sq.mm. F.R.L.S copper wire, in 16gauge 20 mm dia. Rigid Steel conduit, with continuous GI earth wire of 1.5sq.mm. as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 149 39.06 188.00

Page 4: Electrical CSR 12-13

1-5-5 Supplying & erecting mains with 2x4 sq.mm.F.R copper wire, in 16gauge 20 mm dia. Rigid Steel conduit, with continuous GI earth wire of 2.5sq.mm.as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 166 39.06 205.00

1-5-6 Supplying & erecting mains with 2x4 sq.mm.F.R.L.S. copper wire, in 16gauge 20 mm dia. Rigid Steel conduit, with continuous GI earth wire of 2.5sq.mm. as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 171 39.06 210.00

1-5-7 Supplying & erecting mains with 2x6 sq.mm. F.R. copper wire, in 16gauge20 mm dia. Rigid Steel conduit, with continuous GI earth wire of 4sq.mm.as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 197 39.06 236.00

1-5-8 Supplying & erecting mains with 2x6 sq.mm. F.R.L.S copper wire, in16gauge 20 mmdia. Rigid Steel conduit, with continuous GI earth wire of 4sq.mm. as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 206 39.06 245.00

1-5-9 Supplying & erecting mains with 2x10 sq.mm.F.R copper wire, in 16gauge20 mm dia. Rigid Steel conduit, with continuous GI earth wire of 6sq.mm.as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 267 41.17 308.00

1-5-10 Supplying & erecting mains with 2x10 sq.mm.F.R.L.S copper wire, in 16gauge 20 mm dia. Rigid Steel conduit, with continuous GI earth wire of 6sq.mm. as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 195 41.17 236.00

1-5-11 Supplying & erecting mains with 3x4 sq.mm. F.R.copper wire, in 16gauge20 mm dia. Rigid Steel conduit, with continuous GI earth wire of 2.5sq.mm. as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 195 41.17 236.00

1-5-12 Supplying & erecting mains with 3x4 sq.mm. F.R.L.S copper wire, in 16gauge 20 mm dia. Rigid Steel conduit, with continuous GI earth wire of 2.5sq.mm. as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 243 41.17 284.00

1-5-13 Supplying & erecting mains with 3x6 sq.mm. F.R.copper wire, in 16gauge 20 mm dia. Rigid Steel conduit , with continuous GI earth wire of 4sq.mm.as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 243 47.51 291.00

1-5-14 Supplying & erecting mains with 3x6 sq.mm. F.R.L.S copper wire, in 16gauge 20 mm dia.Rigid Steel conduit, with continuous GI earth wire of 4sq.mm. as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 256 47.51 304.00

1-5-15 Supplying & erecting mains with 3x10 sq.mm.F.R copper wire, in 16gauge 25 mm dia. Rigid Steel conduit, with continuous GI earth wire of 6sq.mm. as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 366 52.79 419.00

1-5-16 Supplying & erecting mains with 3x10 sq.mm.F.R.L.S copper wire, in 16gauge 25 mm dia. Rigid Steel conduit, with continuous GI earth wire of 6sq.mm. as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 395 52.79 448.00

1-5-17 Supplying & erecting mains with 4x4 sq.mm. F.R copper wire, in 16gauge 25 mm dia. Rigid Steel conduit, with continuous GI earth wire of 2.5sq.mm. as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 246 46.45 292.00

1-5-18 Supplying & erecting mains with 4x4 sq.mm. F.R.L.S copper wire, in 16gauge 25 mm dia. Rigid Steel conduit, with continuous GI earth wire of 2.5 sq.mm as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 256 46.45 302.00

1-5-19 Supplying & erecting mains with 4x6 sq.mm.F.R copper wire, in 16gauge 25 mm dia.Rigid Steel conduit, with continuous GI earth wire of 4sq.mm. as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 308 46.45 354.00

1-5-20 Supplying & erecting mains with 4x6 sq.mm.F.R L.S copper wire, in 16gauge 25 mmdia. Rigid Steel conduit, with continuous GI earth wire of 4sq.mm. as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 326 46.45 372.00

1-5-21 Supplying & erecting mains with 4x10 sq.mm.F.R copper wire, in 16gauge 32 mm dia. Rigid Steel conduit, with continuous GI earth wire of 6sq.mm. as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 493 55.95 549.00

1-5-22 Supplying & erecting mains with 4x10 sq.mm.F.R.L.S copper wire, in 16gauge 32 mm dia. Rigid Steel conduit, with continuous GI earth wire of 6sq.mm. as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 532 55.95 588.00

1-5-23 Supplying & erecting mains with 6x6 sq.mm.F.R copper wire, in 16 gauge 2 mm dia. Rigid Steel conduit , with continuous GI earth wire of 4sq.mm.as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 446 63.34 509.00

1-5-24 Supplying & erecting mains with 6x6 sq.mm.F.R.L.S copper wire, in 16 gauge 32 mm dia. Rigid Steel conduit, with continuous GI earth wire of 4sq.mm. as per specification No: WG-MA/MC, para no. 1.4.3

Mtr. 472 63.34 535.00

Note :- Add Rs 3/- per meter for erecting conduit on stone wall

1.6 Mains in PVC Conduit (WG-MA/PC) 1-6-1 Supplying & erecting mains 2x1.5 sq.mm.and earth wire 1.5 sqmm F R PVC copper

wire, in rigid PVC conduit min.20mm dia, as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 78 10.56 89.00

1-6-2 Supplying & erecting mains with 2x1.5 sq.mm.and earth wire 1.5 sqmm FRLS PVC copper wire, in rigid PVC conduit min.20mm dia as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 79 10.56 90.00

1-6-3 Supplying & erecting mains with 2x2.5 sq.mm.and earth wire 2.5 sqmm FR PVC copper wire, in rigid PVC conduit min.20mm dia, as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 92 17.95 110.00

1-6-4 Supplying & erecting mains with 2x2.5 sq.mm.and earth wire 2.5 sqmm FRLS PVC copper wire in rigid PVC conduitmin.20mm dia. as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 96 17.95 114.00

Page 5: Electrical CSR 12-13

1-6-5 Supplying & erecting mains with 2x4 sq.mm.and earth wire 2.5 sqmm FR PVC copper wire in rigid PVC conduit min.20mm dia,as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 113 17.95 131.00

1-6-6 Supplying & erecting mains with 2x4 sq.mm.and earth wire 2.5 sq mm FRLS PVC copper wire in rigid PVC conduit min.20mm dia, as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 118 17.95 136.00

1-6-7 Supplying & erecting mains with 2x6 sq.mm.and earth wire 4 sqmm FR PVC copper wire, in rigid PVC conduit min.20mm dia, as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 144 17.95 162.00

1-6-8 Supplying & erecting mains with 2x6 sq.mm.and earth wire 4 sqmm FRLS PVC copper wire, in rigid PVC conduit min.20mm dia, as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 153 17.95 171.00

1-6-9 Supplying & erecting mains with 2x10 sq.mm.and earth wire 6 sqmm FR PVC copper wire, in rigid PVC conduit min.20mm dia, as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 213 22.17 235.00

1-6-10 Supplying & erecting mains with 2x10 sq.mm.and earth wire 6 sqmm FRLS PVC copper wire, in rigid PVC conduit min.20mm dia, as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 233 22.17 255.00

1-6-11 Supplying & erecting mains with 3x4 sq.mm.and earth wire 2.5 sqmm FR PVC copper wire, in rigid PVC conduit min.20mm dia, as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 142 22.17 164.00

1-6-12 Supplying & erecting mains with 3x4 sq.mm.and earth wire 2.5 sqmm FRLS PVC copper wire, in rigid PVC conduit min.20mm dia, as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 151 22.17 173.00

1-6-13 Supplying & erecting mains with 3x6 sq.mm.and earth wire 4 sqmm FR PVC copper wire, in rigid PVC conduit min.20mm dia, as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 190 26.39 216.00

1-6-14 Supplying & erecting mains with 3x6 sq.mm.and earth wire 4 sqmm FRLS PVC copper wire, in rigid PVC conduit min.20mm dia, as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 203 30.62 234.00

1-6-15 Supplying & erecting mains with 3x10 sq.mm.and earth wire 6 sqmm FR PVC copper wire, in rigid PVC conduit min.25mm dia. as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 309 30.62 340.00

1-6-16 Supplying & erecting mains with 3x10 sq.mm.and earth wire 6 sqmm FRLS PVC copper wire, in rigid PVC conduit min.25mm dia,as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 338 30.62 369.00

1-6-17 Supplying & erecting mains with 4x4 sq.mm.and earth wire 2.5 sqmm FR PVC copper wire, in rigid PVC conduit min.25mm dia, as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 189 23.23 212.00

1-6-18 Supplying & erecting mains with 4x4 sq.mm.and earth wire 2.5 sqmm FRLS PVC copper wire, in rigid PVC conduit 25mm dia, as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 199 23.23 222.00

1-6-19 Supplying & erecting mains with 4x6 sq.mm.and earth wire 4 sqmm FR PVC copper wire, in rigid PVC conduit 25mm dia, as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 251 30.62 282.00

1-6-20 Supplying & erecting mains with 4x6 sq.mm.and earth wire 4 sqmmFRLS PVC copper wire, in rigid PVC conduit 25mm dia, as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 269 30.62 300.00

1-6-21 Supplying & erecting mains with 4x10 sq.mm.and earth wire 6 sqmm FR PVC copper wire, in rigid PVC conduit 32mm dia, as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 432 30.62 463.00

1-6-22 Supplying & erecting mains with 4x10 sq.mm.and earth wire 6 sqmm FRLS PVC copper wire, in rigid PVC conduit 32mm dia, as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 471 30.62 502.00

1-6-23 Supplying & erecting mains with 6x6 sq.mm.and earth wire 4 sqmm FR PVC copper wire, in rigid PVC conduit 32mm dia, as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 386 38.01 424.00

1-6-24 Supplying & erecting mains with 6x6 sq.mm.and earth wire 4 sqmm FRLS PVC copper wire, in rigid PVC conduit 32mm dia, as per specification No: WG-MA/PC, para no. 1.4.1

Mtr. 411 38.01 449.00

Note :- 1) Add Rs. 3/- per meter for erecting mains in PVC/HG conduit on stone wall.

Accessories 1.7 Wiring Accessories

1-7-1 Supplying and erecting shockproof 6A ISI mark porcelain base T.Switch / bell push erected on Filled polypropylene ISI marked (IS:14772-2000 board or polished double wooden block / 3 mm thick hylam sheet / 4mm thick plywood pasted with 1.5 mm thick Sunmica with S M screws and duly connected.

Each 37 6.33 43.00

1-7-2 Supplying and erecting One/Two way piano type ISI mark switch 6A./bell push erected on Filled polypropylene ISI marked (IS:14772-2000) board or double polished wooden board/ folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick Sunmica with S M screws and duly connected.

Each 26 6.33 32.00

Page 6: Electrical CSR 12-13

1-7-3 Supplying and erecting ISI mark shockproof T. switch 16 A porcelain base surface mounting type / flush mounting type erected on Filled polypropylene ISI marked (IS:14772-2000) board or polished thick varnished double wooden block/folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with1.5 mm thick Sunmica with S M screws and duly connected.

Each 52 8.45 60.00

1-7-4 Supplying and erecting ISI mark shockproof piano type porcelain base switch 250 V 16 A, erected on Filled polypropylene ISI marked (IS:14772- 2000) board or polished double wooden/ folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick Sunmica with S M screws and duly connected.

Each 56 8.45 64.00

1-7-5 Supplying and erecting ISI mark shockproof 3 pin plug socket 6A with porcelain base / flush type erected on Filled polypropylene ISI marked (IS:14772-2000) board or polished thick varnished double wooden block / folded or screwed board with top of either wooden / 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick Sunmica with S M screws and duly connected.

Each 35 6.33 41.00

1-7-6 Supplying and erecting ISI mark shockproof 3 pin plug socket 16A with porcelain base/ flush type erected on Filled polypropylene ISI marked (IS:14772-2000) board or polished thick varnished double wooden block / folded or screwed board with top of either wooden/3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick Sunmica with S M screws and duly connected.

Each 62 8.45 70.00

1-7-7 Supplying and erecting ISI mark Ceiling rose / Batten holder / Slantingholder / pendent holder bakelite base 6A. erected on Filled polypropylene ISI marked (IS:14772-2000) board or polished double wooden block/ ISI mark PVC junction box.Reduce rates by Rs.5/- for erecting accessories on provided board/ junction box.

Each 15 2.11 17.00

Note :- Reduce rate by Rs.5/-for erecting accessories on provided board / junction box.

1-7-8 Supplying adaptor for lamp holder 230 V.A.C. supply. Each 15 0 15.00 1-7-9 Supplying and erecting ISI mark recess type 3 pin plug socket 6A with

piano switch 6A erected on M.S Box made of 16 SWG sheet duly painted and covered with bakelite hylam sheet of 3 mm thickness connected with earth terminals and leads duly concealed

Each 74 31.67 106.00

1-7-10 Supplying and erecting ISI marked recess type 3 pin plug socket 6A with piano switch 6 A combined unit erected on polished double wooden block/ folded or screwed board with top of either wooden or plywood pasted with sunmica and with connecting leads

Each 52 9.5 62.00

1-7-11 Supplying and erecting ISI mark flush shock proof plug socket 6 pin 6A and 16 A with switch 16A combined unit erected in recess in 16 guage M.S sheet box duly painted and connected with earth terminal and leads

Each 107 31.67 139.00

1-7-12 Supplying and erecting ISI mark flush type shockproof plug socket 6 pin 6A and 16A with switch 16A combined unit erected on Filled polypropylene ISI marked (IS:14772-2000) board or double wooden block / 3mm thick hylam sheet / 4mm thickplywood pasted with 1.5 mm thick sunmica with S M screws and duly connected.

Each 96 9.5 106.00

1-7-13 Supplying and erecting flush type shockproof plug socket 6A.& 16A (6 pin) with 16A switch combined with indicator lamp and fuse with gang box on wooden board.

Each 128 13.72 142.00

1-7-14 Supplying and erecting ISI mark shockproof bell push on Filled polypropylene ISI marked (IS:14772-2000) board or wooden block covered with sunmica with 2 Core (TRS type) PVC insulated copper wire of size 0.5 sq mm 5 m length connected to the point.

Each 42 9.5 52.00

1-7-15 Supplying and erecting ISI marked recess type 3 pin plug socket 6A with piano switch 6A combined unit erected on M.S box made of 16 guage sheet and covered with sunmica and with connecting leads

Each 68 15.84 84.00

1-7-16 Concealing the provided MS / PVC switch box in wall with finishing in an approved manner

Each 4 31.67 36.00

1.8 Modular switches and Accessories 1-8-1 Supplying and erecting modular type switch 6A / 10A ISI mark approved make duly

erected on provided plate and box with wiring connections complete.

Each 87 9.5 97.00

1-8-2 Supplying and erecting modular type switch 16A ISI mark approved make duly erected on provided plate and box with wiring connections complete.

Each 116 9.5 126.00

1-8-3 Supplying and erecting modular type bell-push 6A / 10A ISI mark approved make duly erected on provided plate and box with wiring connections complete.

Each 101 9.5 111.00

1-8-4 Supplying and erecting modular type bell-push with indicator 2 modules 6A / 10A ISI mark approved make duly erected on provided plate and box with wiring connections complete.

Each 113 9.5 123.00

1-8-5 Supplying and erecting modular type Two way switch 6A / 10A (2 Module) ISI mark, approved make, duly erected on provided plate and box with wiring connections complete.

Each 101 9.5 111.00

1-8-6 Supplying and erecting modular type switch 16 / 20 A with indicator, ISI mark, approved make duly erected on provided plate and box with wiring connections complete.

Each 149 9.5 159.00

Page 7: Electrical CSR 12-13

1-8-7 Supplying and erecting modular type switch one way 16 / 20 A, ISI mark, approved make duly erected on provided plate and box with wiring connections complete with neon indicator.

Each 164 9.5 174.00

1-8-8 Supplying and erecting modular type D.P. switch 32A with indicator ISI mark approved make duly erected on provided plate and box with wiring connections complete.

Each 208 9.5 218.00

1-8-9 Supplying and erecting modular type 32A, DP energy saving switch withBrass KEY TAG ISI mark approved make duly erected on provided plate and box with wiring connections complete.

Each 399 9.5 409.00

1-8-10 Supplying and erecting modular type 3 pin 6A multi socket with safety shutter ISI mark approved make duly erected on provided plate and box with wiring connections complete.

Each 104 9.5 114.00

1-8-11 Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter ISI mark approved make duly erected on provided plate and box with wiring connections complete.

Each 207 9.5 217.00

1-8-12 Supplying and erecting modular type indicator lamp ISI mark approvedmake duly erected on provided plate and box with wiring connections complete.

Each 63 9.5 73.00

1-8-13 Supplying and erecting modular type 6 / 16A fuse unit ISI mark approved make duly erected on provided plate and box with wiring connections complete.

Each 100 9.5 110.00

1-8-14 Supplying and erecting modular type T.V. socket single outlet ISI mark approved make duly erected on provided plate and box with wiring connections complete.

Each 92 9.5 102.00

1-8-15 Supplying and erecting modular type telephone socket one gang with safety shutter ISI mark approved make duly erected on provided plate and box with wiring connections complete.

Each 90 9.5 100.00

1-8-16 Supplying and erecting modular type telephone socket two gang with safety shutter ISI mark approved make duly erected on provided plate and box with wiring connections complete.

Each 111 9.5 121.00

1-8-17 Supplying and erecting modular type computer Jack RJ 45 with safety shutter ISI mark approved make duly erected on provided plate and box with wiring connections complete.

Each 146 9.5 156.00

1-8-18 Supplying and erecting modular type bell indicator ISI mark approved make duly erected on provided plate and box with wiring connections complete.

Each 179 9.5 189.00

1-8-19 Supplying and erecting modular type buzzer 220 / 250V ISI mark approved make duly erected on provided plate and box with wiring connections complete.

Each 114 9.5 124.00

1-8-20 Supplying and erecting modular type electronic dimmer 400 / 450W one module ISI mark approved make duly erected on provided plate and box with wiring connections complete.

Each 268 9.5 278.00

1-8-21 Supplying and erecting modular type electronic dimmer 600W two module ISI mark approved make duly erected on provided plate and box with wiring connections complete.

Each 375 9.5 385.00

1-8-22 Supplying and erecting modular type electronic dimmer 1000W two module ISI mark approved make duly erected on provided plate and box with wiring connections complete.

Each 601 9.5 611.00

1-8-23 Supplying and erecting modular type electronic step regulator two module ISI mark approved make duly erected on provided plate and box with wiring connections complete.

Each 346 9.5 356.00

1-8-24 Supplying and erecting modular type cover for junction box ISI mark approved make duly erected on provided box.

Each 31 9.5 41.00

1-8-25 Supplying and erecting modular type blanking plate one module ISI mark approved make duly erected on provided plate & box.

Each 19 0 19.00

1-8-26 Supplying and erecting modular type blanking plate two module ISI mark approved make duly erected on provided plate & box.

Each 35 0 35.00

1-8-27 Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected in an approved manner.

Each 94 29.56 124.00

1-8-28 Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module duly erected in an approved manner.

Each 94 29.56 124.00

1-8-29 Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected in an approved manner.

Each 114 33.78 148.00

1-8-30 Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected in an approved manner.

Each 129 33.78 163.00

1-8-31 Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected in an approved manner.

Each 188 33.78 222.00

1-8-32 Supplying and erecting PVC Surface modular switch box with inner plate (mounting) & front plate for 8 module complete duly connected.

Each 242 33.78 276.00

1-8-33 Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module duly erected in an approved manner.

Each 309 33.78 343.00

1-8-34 Supplying and erecting PVC Surface modular switch box with double mounting plate for 16 / 18 module duly erected in an approved manner.

Each 332 33.78 366.00

Page 8: Electrical CSR 12-13

1-8-35 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiseling and finishing with cement morter / POP as per required to match the background in an approved manner.

Each 96 85.51 182.00

1-8-36 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner.

Each 104 85.51 190.00

1-8-37 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner.

Each 104 85.51 190.00

1-8-38 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner.

Each 128 85.51 214.00

1-8-39 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner.

Each 212 85.51 298.00

1-8-40 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner.

Each 261 141.46 402.00

1-8-41 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner.

Each 261 141.46 402.00

1-8-42 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner.

Each 334 141.46 475.00

1-8-43 Supplying and erecting White Footlight with 4 modules concealed modular box and lamp holder with cover complete erected on wall /flush to wall with necessary chiselling in wall and finishing with cement and morter / POP as per required and duly connected in an approved manner.

Each 485 85.51 571.00

1-8-44 Supplying and erecting White Footlight with 8 modules concealed modular box and lamp holder with cover complete erected on wall /flush to wall with necessary chiselling in wall and finishing with cement and morter / POP as per required and duly connected in an approved manner.

Each 605 85.51 691.00

1-8-45 Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected.

Each 456 43.28 499.00

1-8-46 (New)

Supplying and erecting 6 to 32 A SPMCB suitable to fix in 1 module of modular switch in provided box complete & duly concealed with necessary material and connected.

Each 124 9.5 134.00

1-8-47 (New)

Supplying and erecting 16 to 32 A DPMCB suitable to fix in 2 module of modular switch in provided box complete & duly concealed with necessary material and connected.

Each 285 9.5 295.00

Note :- For supplying and erecting modular switches without box, deduct following amount from overall rates of respective above items 1) Rs 31/- for 1& 2 module plate 2) Rs 38/- for 3 module plate 3) Rs 43/- for 4 module plate 4) Rs 75/- for 6 module plate 5) Rs 86/- for 8 module plate 6) Rs 102/- for 12 module plate 7) Rs 143/- for 16/18 module plate

Point Wiring (PW) 1.9 Point Wiring (WG-PW)

1-9-1 Point wiring for light/fan/bell in 20 mm metal conduit with 1.0 sqmm FR grade Copper wire with flush type switch and required accessaries as per specification No: WG-PW/SW

Point 492 172.08 664.00

1-9-2 Point wiring in for light/fan/bell in 20 mm metal conduit with 1.0 sqmm FRLS grade Copper wire with flush type switch and required accessaries as per specification No: WG-PW/SW

Point 497 172.08 669.00

1-9-3 Point wiring for independent plug in 20 mm metal conduit with 1.0 sqmm FR grade Copper wire with flush type switch and required accessaries as per specification No: WG-PW/SW

Point 501 193.19 694.00

1-9-4 Point wiring for independent plug in 20 mm metal conduit with 1.0 sqmm FRLS grade Copper wire with flush type switch and required accessaries as per specification No: WG-PW/SW

Point 506 193.19 699.00

1-9-5 Point wiring for light/fan/bell in 20 mm rigid PVC conduit with 1.0 sqmm FR grade Copper wire with flush type switch and required accessaries as per specification No: WG-PW/SW

Point 334 91.85 426.00

Page 9: Electrical CSR 12-13

1-9-6 Point wiring for light/fan/bell in 20 mm rigid PVC conduit with 1.0 sqmm FRLS grade Copper wire with flush type switch and required accessaries as per specification No: WG-PW/SW

Point 339 91.85 431.00

1-9-7 Point wiring for independent plug in 20 mm rigid PVC conduit with 1.0 sqmm FR grade Copper wire with flush type switch and required accessaries as per specification No: WG-PW/SW

Point 342 114.02 456.00

1-9-8 Point wiring for independent plug in 20 mm rigid PVC conduit with 1.0 sqmm FRLS grade Copper wire with flush type switch and required accessaries as per specification No: WG-PW/SW

Point 348 114.02 462.00

1-9-9 Point wiring for light/fan/bell consealed type in min 20 mm PVC conduit with 1.5 sq.mm. FR grade copper wires with moduler type switch and required accessaries as per specification No: WG-PW/CW

Point 439 233.31 672.00

1-9-10 Supplying and Drawing of 2x1.5 sq.mm. FRLS grade copper wires in provided concealed pipes for concealed type light/fan/bell point wiringand terminating on modular accessories in box for point wiring for light/fan/bell as per specification No: WG-PW/CW

Point 337 90.79 428.00

1-9-11 Point wiring for independent plug, concealed type in min 20 mm PVC conduit with 1.5 sq.mm FRLS grade copper wires with moduler type switch and socket and required accessaries as per specification No WG- PW/SW

Point 742 264.98 1007.00

1-9-12 Supplying and drawing of 2x1.5 sq.mm. FRLS grade copper wires in provided concealed pipes and terminating on moduler accessories in box for point wiring for independent plug as per specification No WG-PW/SW

Point 543 90.79 634.00

1-9-13 Wiring for plug on board with Switch socket with copper wiring and earthing as per specification No:WG-PW/SW

Point 62 13.72 76.00

1-9-14 Wiring for plug on board with Switch socket concealed type with copper wiring, earthing and with modular accessories as per specification No: WG- PW/CW

Point 315 55.95 371.00

1-9-15 Conversion of light point into fan point in PVC conduit / PVC truncking with suitable Filled polypropylene ISI marked (IS:14772-2000) board or double wooden board for regulator, switches and with ceiling rose erected on PVC block.

Point 39 30.62 70.00

1-9-16 Point wiring in PVC trunking (casing-capping) with 1.0 sqm FR grade copper wire with flush type switchand required accessaries as per specification No: WG-PW/SW

Point 193 98.18 291.00

1-9-17 Point wiring in PVC trunking (casing-capping) with 1.0 sqm FRLS grade copper wire with flush type switch and required accessaries as per specification No: WG-PW/SW

Point 198 98.18 296.00

1-9-18 Point wiring for independent plug in PVC trunking (casing-capping) with 1.0 sqm FR grade copper wire with flush type switchand required accessaries as per specification No: WG-PW/SW

Point 306 118.24 424.00

1-9-19 Point wiring for independent plug in PVC trunking (casing-capping) with 1.0 sqm FRLS grade copper wire with flush type switchand required accessaries as per specification No: WG-PW/SW

Point 312 118.24 430.00

1-9-20 Concealing provided M.S./ PVC switch box in wall with finishing in an approved manner as per specification No: WG-PW/CW

Each 13 31.67 45.00

1-9-21 Concealing of provided ISI mark G.I. pipe/H.G. screwed conduit/PVC pipe in wall/floor/false ceiling complete as per specification No:WG- PW/CW

Mtr. 13 29.56 43.00

1-9-22 Refilling the holes for dismantled point wiring with cement mortar & finishing in an approved manner.

Point 12 5.28 17.00

Note :- 1) For point wiring above 6 meters of length of, add 10 % of overall rate of point wiring for every additional 1 meter length or part thereof. 2)Point wiring starts from Main board/Intermediate switch board and suitable circuit mains are to be provided from D.B. to first board and between boards.

3) For point wiring in stair case with 2 way control point increase overall rate by 50 % of light point wiring. 4) For wiring on stone wall add Rs 15.00 per point wiring. 5) For covering at wall entries acrylic sheet of appropriate size shall be provided. (Refer Item No. 6-1-9) 6) Whenever point wiring with modular switches are required add Rs. 136 /- per point for light ,bell,exhaust fan & Fan point, Rs. 228/- for independent plug point or plug on board. 7) For Concealed point wiring, instead of Modular switches & accessories, ordinary switches & accessories are to used, than deductRs. 136 /- for point wiring & Rs. 228 /- for Independent plug point wiring and Rs. 228 /- for plug on board, from overall rates. 8) Deduct Rs 31/- from overall rate of point wiring for Light/fan/bell/exhaust fan point and Rs 38/- from overall rate of pointwiring for IP/Plug on board if point wiring to be provided without modular box (i.e point wiring to be provided on modular furniture or such parallel installations where modular box is not required)

9) For Concealed type wiring only FR Grade wire shall be used. FR - Fire Retardant FRLS - Fire Retardant Low Smoke.

1.10 Telephone Wiring (WG-TW/TW) 1-10-1 Supplying & erecting telephone cable 1 pair with 0.5 mm dia. laid in provided PVC

casing / conduit as per specification No. WG-TWMtr. 7 2.11 9.00

Page 10: Electrical CSR 12-13

1-10-2 Supplying & erecting telephone cable 2 pair with 0.5 mm dia. laid in provided PVC casing / conduit asper specification No. WG-TW

Mtr. 12 5.28 17.00

1-10-3 Supplying & erecting telephone cable 3 pair with 0.5 mm dia. laid in provided PVC casing / conduit as per specification No. WG-TW

Mtr. 17 5.28 22.00

1-10-4 Supplying & erecting telephone cable 4 pair with 0.5 mm dia. laid in provided PVC casing / conduit as per specification No. WG-TW

Mtr. 23 5.28 28.00

1-10-5 Supplying & erecting telephone cable 5 pair with 0.5 mm dia. laid in provided PVC casing / conduit as per specification No. WG-TW

Mtr. 28 5.28 33.00

1-10-6 Supplying & erecting telephone cable 10 pair with 0.5 mm dia. laid in provided PVC casing / conduit asper specification No. WG-TW

Mtr. 50 5.28 55.00

1-10-7 Supplying & erecting telephone cable 20 pair with 0.5 mm dia. laid in provided PVC casing / conduit asper specification No. WG-TW

Mtr. 94 7.39 101.00

1-10-8 Supplying & erecting telephone cable 50 pair with 0.5 mm dia. laid in provided PVC casing / conduit asper specification No. WG-TW

Mtr. 231 7.39 238.00

1-10-9 Supplying & erecting telephone cable 100 pair with 0.5 mm dia. laid in provided PVC casing / conduit as per specification No. WG-TW

Mtr. 444 7.39 451.00

1-10-10 Supplying & erecting Jelly filled armoured telephone cable 10 pair with0.5 mm dia. laid in provided trench asper specification No. WG-TW

Mtr. 83 7.39 90.00

1-10-11 Supplying & erecting Jelly filled armoured telephone cable 20 pair with 0.5 mm dia. laid in provided trench as per specification No. WG-TW

Mtr. 117 7.39 124.00

1-10-12 Supplying & erecting Jelly filled armoured telephone cable 50 pair with 0.5 mm dia. laid in provided trench as per specification No. WG-TW

Mtr. 218 7.39 225.00

1-10-13 Supplying & erecting Jelly filled armoured telephone cable 100 pair with 0.5 mm dia. laid in provided trench as per specification No. WG-TW

Mtr. 391 7.39 398.00

1-10-14 Supplying & erecting Jumper wire with 0.5 mm dia as per specification No. WG-TW Mtr. 15 2.11 17.00

1-10-15 Supplying & installing Co-axial cable low voltage grade RG-11 as per specification No. WG-TW

Mtr. 54 2.11 56.00

1.11 Telephone Accessories (WG-TW/TA) 1-11-1 Supplying, erecting & commissioning Main Distribution Frame (MDF) Box 50x50

pairs as per specification No. WG-TWEach 1516 142.52 1659.00

1-11-2 Supplying, erecting & commissioning MDF Box 60 x 60 pairs as per specification No. WG-TW

Each 1589 142.52 1732.00

1-11-3 Supplying, erecting & commissioning MDF Box 100 x 100 pairs as per specification No. WG-TW

Each 2423 142.52 2566.00

1-11-4 Supplying, erecting & commissioning MDF Box 150 x 150 pairs as per specification No. WG-TW

Each 3330 203.75 3534.00

1-11-5 Supplying, erecting & commissioning MDF Box 200 x 200 pairs as per specification No. WG-TW

Each 4986 203.75 5190.00

1-11-6 Supplying, erecting & commissioning MDF Box 250 x 250 pairs as per specification No. WG-TW

Each 5893 330.43 6223.00

1-11-7 Supplying, erecting & commissioning MDF Box 300 x 300 pairs as per specification No. WG-TW

Each 7108 330.43 7438.00

1-11-8 Supplying, erecting & commissioning MDF Box 400 x 400 pairs as per specification No. WG-TW

Each 10400 456.06 10856.00

1-11-9 Supplying, erecting & commissioning MDF Box 500 x 500 pairs as per specification No. WG-TW

Each 12918 659.81 13578.00

1-11-10 Supplying, erecting & commissioning MDF Box 600 x 600 pairs as per specification No. WG-TW

Each 15098 659.81 15758.00

1-11-11 Supplying, erecting & commissioning MDF Box 800 x 800 pairs as per specification No. WG-TW

Each 23107 658.76 23766.00

1-11-12 Supplying, erecting & commissioning Junction box suitable for 10 pairs as per specification No. WG-TW

Each 520 41.17 561.00

1-11-13 Supplying, erecting & commissioning Junction box suitable for 20 pairs as per specification No. WG-TW

Each 557 41.17 598.00

1-11-14 Supplying, erecting & commissioning Junction box suitable for 30 pairs as per specification No. WG-TW

Each 748 41.17 789.00

1-11-15 Supplying, erecting & commissioning Junction box suitable for 40 pairs as per specification No. WG-TW

Each 784 41.17 825.00

1-11-16 Supplying, erecting & commissioning Junction box suitable for 50 pairs as per specification No. WG-TW

Each 922 41.17 963.00

1-11-17 Supplying, erecting & commissioning Junction box suitable for 60 pairs as per specification No. WG-TW

Each 959 61.23 1020.00

1-11-18 Supplying, erecting & commissioning Junction box suitable for 100 pairs as per specification No. WG-TW

Each 1437 106.63 1544.00

1-11-19 Supplying, erecting & commissioning Junction box suitable for 150 pairs as per specification No. WG-TW

Each 1754 106.63 1861.00

1-11-20 Supplying, erecting & commissioning Krone module of 10 pairs as per specification No. WG-TW

Each 207 164.69 372.00

1-11-21 Supplying & erecting Over Voltage protection Magazine suitable for 10 pair as per specification No. WG-TW

Each 206 38.01 244.00

1-11-22 Supplying & erecting Rosette box RJ type Bakelite box on wall with LED indication duly connected as per specification No. WG-TW

Each 86 12.67 99.00

1-11-23 Supplying, installing, testing & commissioning analogue type PBX (Private Branch Exchange ) of 3 x 8 extension as per specification No. WG-TW

Job 17599 1445.25 19044.00

1-11-24 Supplying, installing, testing & commissioning analogue type PBX 4 x 12 extension as per specification No. WG-TW

Job 19418 1445.25 20863.00

Page 11: Electrical CSR 12-13

1-11-25 Supplying, installing, testing & commissioning analogue type PBX 4 x 24 extension as per specification No. WG-TW

Job 48545 1445.25 49990.00

1-11-26 Supplying, installing, testing & commissioning analogue type PBX 4 x 32 extension as per specification No. WG-TW

Job 58253 1445.25 59698.00

1-11-27 Supplying, installing, testing & commissioning analogue type PBX 8 x 24 extension as per specification No. WG-TW

Job 50970 2777.55 53748.00

1-11-28 Supplying, installing, testing & commissioning analogue type PBX 8 x 32 extension as per specification No. WG-TW

Job 60075 2777.55 62853.00

1-11-29 Supplying, installing, testing & commissioning analogue type PBX 8 x 40 extension as per specification No. WG-TW

Job 70997 2777.55 73775.00

1-11-30 Supplying, installing, testing & commissioning Digital type EPABX (Electronic Private Automatic Branch Exchange) of 8 x 16 extension as per specification no. WGTW

Job 46603 4265.03 50868.00

1-11-31 Supplying, installing, testing & commissioning Digital type EPABX 8 x 24 extension as per specification No. WG-TW

Job 62137 4265.03 66402.00

1-11-32 Supplying, installing, testing & commissioning Digital type EPABX 8 x 32 extension as per specification No. WG-TW

Job 77671 4265.03 81936.00

1-11-33 Supplying, installing, testing & commissioning Digital type EPABX 8 x 40 extension as per specification No. WG-TW

Job 98448 4265.03 102713.00

1-11-34 Supplying, installing, testing & commissioning Digital type EPABX 8 x 48 extension as per specification No. WG-TW

Job 112258 4265.03 116523.00

1.12 Computer Cabling (WG-COC) 1-12-1 Supplying & installing UTP networking Cat-6 cable suitable for LAN / WAN

Computer net-working as per specification No. WG-COC/NCMtr. 27 7.39 34.00

1-12-2 Supplying & installing UTP networking Cat-6+ cable suitable for LAN / WAN Computer net-working as per specification no. WG-COC/NC

Mtr. 29 7.39 36.00

1-12-3 Supplying and fixing 1 meter length, UTP Patch cord of Cat 6 type in position as per specification No. WG-COC/PC

Each 221 13.72 235.00

1-12-4 Supplying and fixing 3 meter length, UTP Patch cord of Cat 6 type in position as per specification No. WG-COC/PC

Each 309 13.72 323.00

1-12-5 Supplying and erecting FR grade, PVC armoured multimode Optical Fibre Cable with 6 fibres, with core dia 50 µm, suitable for 1 GBps ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC

Mtr. 113 34.84 148.00

1-12-6 Supplying and erecting FR grade, PVC armoured multimode Optical Fibre Cable with 12 fibres, with core dia 50 µm, suitable for 1 GBps ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC

Mtr. 168 34.84 203.00

1-12-7 Supplying and erecting FR grade, PVC armoured multimode Optical Fibre Cable with 24 fibres, with core dia 50 µm, suitable for 1 GBps ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC

Mtr. 461 34.84 496.00

1-12-8 Supplying and erecting FR grade, PVC armoured multimode Optical Fibre Cable with 6 fibres, with core dia 62.5 µm, suitable for 1 GBps ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench asper specification No. WG-COC/OFC

Mtr. 106 34.84 141.00

1-12-9 Supplying and erecting FR grade, PVC armoured multimode Optical Fibre Cable with 12 fibres, with core dia 62.5 µm, suitable for 1 GBps ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC

Mtr. 162 34.84 197.00

1-12-10 Supplying and plugging FRLS duplex 1 meter length, Fibre Patch cord into the LC/FC/SC/ST termination of LIU & fibre module/ fibre switch port complete as per specification No. WG-COC/FPC

Each 2823 34.84 2858.00

1.13 Networking Components (WG- COC/NWC) 1-13-1 Supplying, fixing, and configuring Web Smart Power over Ethernet Switch of 24

Ports , 4-GB Ports and 2 SFP slots with WebView , on provided rack or as directed as per specification No. WG-NWC/ENS

Each 38610 2755.38 41365.00

1-13-2 Supplying, fixing, and configuring GB Managed Ethernet Switch of 24 Ports with 2 SFP Combo slots and WebView, on provided rack or as directed as per specification no. WG-NWC/GBS

Each 37106 2066 39172.00

1-13-3 Supplying, fixing, and configuring Broadband ADSL Router with all accessories, on provided rack or as directed as per specification No. WG- NWC/ADSL

Each 1512 482.45 1994.00

1-13-4 Supplying and fixing Indoor LAN Dipole Antenna suitable for Wireless LAN with all accessories as per specification No. WG-NWC/DPA

Each 6528 482.45 7010.00

1-13-5 Supplying and fixing Omni Directional Antenna suitable for Wireless LAN with all accessories as per specification No. WG-NWC/ODA

Each 6586 482.45 7068.00

1-13-6 Supplying and fixing Aesthetic Omni Directional Antenna suitable for Wireless LAN with all accessories as per specification No. WG- NWC/AODA

Each 7280 482.45 7762.00

1.14 Networking Accessories (WG-COC/NAS) 1-14-1 Supplying, installing & testing UTP Connector (RJ-45) as per specification

No. WG-NAS/UTPC.Each 14 7.39 21.00

1-14-2 Supplying and fixing Tool-less Information Outlet (Ethernet) flush/surface type in position as per specification no. WG-NAS/IO

Each 493 34.84 528.00

Page 12: Electrical CSR 12-13

1-14-3 Supplying and fixing Tool-less Keystone Jack (RJ-45) in provided Patch Panel complete as per specification no. WG-NAS/KJ

Each 490 34.84 525.00

1-14-4 Supplying and fixing 24 port Patch Panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP

Each 7928 688.32 8616.00

1-14-5 Supplying and fixing Wall/Rack type 12 Ports, Light guide InterconnectUnit for termination of Optical fibre cables on wall/ provided U Rack complete as per specification no. WG-NAS/ LIU

Each 3472 551.08 4023.00

1-14-6 Supplying and fixing Wall/Rack type 24 Ports, Light guide Interconnect Unit for termination of Optical fibre cables on wall/ provided U Rack complete as per specification no. WG-NAS/ LIU

Each 6944 826.61 7771.00

1-14-7 Supplying and fixing ST "D" type Multimode Adaptor to couple two connectors between OFC & Fibre switch/Fibre module as per specification no. WG-NAS/MMA

Each 224 68.62 293.00

1-14-8 Supplying and fixing ST "D" type Multimode connector for LIU to terminate OFC in LIU. as per specification no. WG-NAS/LIU1

Each 865 413.83 1279.00

1-14-9 Supplying and fixing No Epoxy No Polish, ST "D" type Multimode connector for LIU to terminate OFC in LIU as per specification No. WG- NAS/LIU2

Each 865 175.25 1040.00

1-14-10 Supplying and fixing Power over Ethernet Adaptor to provide DC supply to Ehternet devices as per specification No. WG-NAS/PEA

Each 2727 175.25 2902.00

1-14-11 Supplying and fixing 36 U Rack for Networking with necessary arrangement for fixing required 16A/6A Switches & Plugs for LAN network as per specification No. WG-NAS/RAK

Each 29120 1102.15 30222.00

1-14-12 Supplying and fixing Wireless PCI LAN (108 Mbps) card in provided computer as per specification No. WG-NAS/LANC2

Each 1811 482.45 2293.00

1-14-13 Supplying and fixing Manageable Wireless LAN Access Point with PoE (Power over Ethernet) in WLAN network as per specification no. WG- NAS/LAP1

Each 13914 2066 15980.00

1-14-14 Supplying and fixing High Performance Manageable Wireless LAN Access Point with PoE (Power over Ethernet) in WLAN network as per specification no. WG-NAS/LAP2

Each 26058 2755.38 28813.00

1-14-15 Supplying and fixing Dual Band High Performance Manageable Wireless LAN Access Point with PoE (Power over Ethernet) in WLAN network as per specification as No. WG-NAS/LAP3

Each 53794 6357.43 60151.00

1.15 Dismantling 1-15-1 Dismantling the existing light, fan, bell, clock, independent plug point, wiring with

mains of all types alongwith accessories etc.Complete as per specification No: WG-PW/DM

Point -1 5.28 4.00

1-15-2 Dismantling the existing Telephone / Lan / Wan / TV cables and wires of all sizes along with casing-capping / conduit complete as per specification No: WG-PW/DM

Mtr. -1 5.28 4.00

Note :- Dismantled material of Point wiring shall be retained by contractor.

Chapter 2 : FITTINGS (FG)

2.1 Lamps ( FG-LP) 2-1-1 Supplying & erecting GLS lamp 230 V, 10 W.. Each 15 1.06 16.00 2-1-2 Supplying & erecting GLS lamp 230 V, 15 W. Each 14 1.06 15.00 2-1-3 Supplying & erecting GLS lamp 230 V, 25 W. Each 15 1.06 16.00 2-1-4 Supplying & erecting GLS lamp 230 V, 40 W. Each 16 1.06 17.00 2-1-5 Supplying & erecting GLS lamp 230 V, 60 W. Each 16 1.06 17.00 2-1-6 Supplying & erecting GLS lamp 230 V,100 W. Each 16 1.06 17.00 2-1-7 Supplying & erecting Electronic night lamp 0.5 W LED high glow. Each 207 1.06 208.00 2-1-8 Supplying & erecting milky / coated / frosted lamp 250 V 40W / 60W Each 18 1.06 19.00 2-1-9 Supplying & erecting fluorescent tube day light 600 mm, 18W Each 50 1.06 51.00 2-1-10 Supplying & erecting fluorescent tube day light 1200 mm, 36W Each 51 2.11 53.00 2-1-11 Supplying & erecting T5 28W Energy efficient fluorescent tube. Each 134 2.11 136.00 2-1-12 Supplying & erecting T8 36W fluorescent tube tri-Phospher/Tru- band phospher with

3250 lumen output.Each 97 2.11 99.00

2-1-13 Supplying and erecting T-5 14W Energy efficient fluoroscent tube. Each 131 2.11 133.00 2-1-14 Supplying and erecting T-5 24W Energy efficient fluoroscent tube. Each 178 2.11 180.00 2-1-15 Supplying & erecting pigmy /candle lamp miniature type coloured / white. Each 24 1.06 25.00 2-1-16 Supplying & erecting M V lamp 3 pin BC / Screwed cap head / pin type 230 V, 80 W. Each 180 15.84 196.00

2-1-17 Supplying & erecting MV lamp 3 pin BC / Screwed cap head / pin type 230 V, 125 W.

Each 185 15.84 201.00

2-1-18 Supplying & erecting MV lamp 3 pin BC / Screwed cap head / pin type 230 V, 250 W.

Each 367 15.84 383.00

2-1-19 Supplying & erecting MV lamp 3 pin BC / Screwed cap head / pin type 230 V, 400 W.

Each 485 15.84 501.00

2-1-20 Supplying & erecting Mercury blended lamp 230 V, 160 W. Each 267 15.84 283.00 2-1-21 Supplying & erecting H.P.S.V. lamp 3 pin B.C / screwed cap head type 230 V, 70W

[SON type]Each 382 15.84 398.00

2-1-22 Supplying & erecting H.P.S.V.lamp 3 pin B.C./ screwed cap head type 230 V, 150W [SON type]

Each 579 15.84 595.00

Page 13: Electrical CSR 12-13

2-1-23 Supplying & erecting H.P.S.V.lamp 3 pin B.C./ screwed cap head type 230 V, 250W [SON type]

Each 643 15.84 659.00

2-1-24 Supplying & erecting H.P.S.V.lamp threaded type 230V, 400W [SON type] Each 778 15.84 794.00 2-1-25 Supplying and erecting H.P.S.V. lamp 3 pin B.C. type 230V, 70W [SON-T

type]Each 396 15.84 412.00

2-1-26 Supplying & erecting H.P.S.V. lamp threaded type 230V,150W [SON-T type.] Each 602 15.84 618.00

2-1-27 Supplying & erecting H.P.S.V.lamp threaded type 230V, 250W [SON-T type] Each 667 15.84 683.00

2-1-28 Supplying and erecting H.P.S.V.lamp 3 pin B.C./screwed cap head type 230V, 400W [SON-T type]

Each 801 15.84 817.00

2-1-29 Erection of departmently supplied H.P.S.V./ H.P.M.V ./ SON / SON-T Lamp Each 0 15.84 16.00 2-1-30 Supplying & erecting Metal Halide lamp,double ended, 230V,70W. Each 661 15.84 677.00 2-1-31 Supplying & erecting Metal Halide lamp, double ended, 230V, 150 W. Each 719 15.84 735.00 2-1-32 Supplying & erecting Metal Halide lamp,230V, 250 W double ended. Each 1071 15.84 1087.00 2-1-33 Supplying & erecting Metal Halide lamp,230V, 400 W double ended. Each 1130 15.84 1146.00 2-1-34 Supplying & erecting Halogen lamp 230 V. 500 W Each 103 15.84 119.00 2-1-35 Supplying & erecting Halogen lamp 230 V. 1000 W Each 115 15.84 131.00 2-1-36 Supplying & erecting compact fluo.lamp 10 / 13 W, 230 V, to be used with provided

ballastEach 131 15.84 147.00

2-1-37 Supplying & erecting compact fluo.lamp18 W, 230V to be used with provided ballast Each 151 15.84 167.00

2-1-38 Supplying & erecting compact fluo.lamp 5 / 7 / 9 / 11 W, 230 V to be used with provided ballast.

Each 98 15.84 114.00

2-1-39 Supplying & erecting compact fluo.lamp 36 W, 230 V to be used with provided ballast.

Each 214 15.84 230.00

2-1-40 Supplying and erecting compact fluo.lamps 2 W, 230V intergral type complete with ceramic adopter p.f more than 0.9

Each 105 2.11 107.00

2-1-41 Supplying and erecting compact fluoresent lamp 5W / 8 W, 230V integral type complete with ceramic adopter and having p.f more than 0.9

Each 139 2.11 141.00

2-1-42 Supplying and erecting compact fluo.lamps 9 / 11 W, 230V.intergral type complete with ceramic adopter and having p.f more than 0.9

Each 144 2.11 146.00

2-1-43 Supplying and erecting compact fluo.lamps 14 / 15 W, 230V intergral type complete with ceramic adopter and having p.f more than 0.9

Each 156 2.11 158.00

2-1-44 Supplying and erecting compact fluo.lamps 18 to 20 W, 230V, intergral type complete with ceramic adopter and having p.f more than 0.9

Each 203 2.11 205.00

2-1-45 Supplying and erecting compact fluorescent lamp 22 to 26 W, 230 V integral type complete with ceramic adopter and having p.f more than 0.9

Each 232 2.11 234.00

2-1-46 Supplying and erecting compact fluo.lamps 27 to 36 W, 230V.intergral type complete with ceramic adopter and having p.f more than 0.9

Each 343 2.11 345.00

2-1-47 Supplying and erecting compact fluo.lamps 45 / 65 W, 230V. intergral type complete with ceramic adopter and having p.f more than 0.9

Each 706 2.11 708.00

2-1-48 (New)

Supplying and erecting LED lamps 2/3 W, 230V. intergral type complete with ceramic adopter and having p.f more than 0.9

Each 260 3.17 263.00

2-1-49 (New)

Supplying and erecting LED lamps 5 W, 230V. intergral type complete with ceramic adopter and having p.f more than 0.9

Each 677 3.17 680.00

Note :- 1) On Govt installation ,energy efficient lamps (CFL, T-5, T-8 (tri-band phosphor)) shall be preferably used. 2) Use of GLS lamps shall be avoided and also to be intimated to other departments. 3) For use of Single ended Metal Halide Lamp increase overall rate by 40 % in the rate for Double ended lamp. (2-1-30 to 2-1-33) 4) On Govt. installation use of Electronic chokes/energy saver accessories, are mandatory and as such conventional chokes shall not be used. 5) Lamps & tubes shall be used invariably of three star and above ratings as per BEE circular. 6) Above rates are for lamps to be provided in new fittings and if lamps are to be provided/replaced in existing fittings add in labour rate Rs 5/- for tubes and Rs.10/- for MV/SV/MH lamps.

2.2 Indoor Fittings (FG-IDF) 2-2-1 Supplying table lamp with M.S. tube with flexible joints complete suitable for

lamp 1XPL- 5 / 7/ 9 W complete with lamp and 3 core round plastic flexible cord with 6A 3 pin hand shield type plug top.

Each 995 0 995.00

2-2-2 Supplying shock proof type hand lamp with lamp holder,guarded glass and 10 mtrs of 3 core PVC flexible cord with hand shield type 3 pin 6 Amp plug top.

Each 139 0 139.00

2-2-3 Supplying approved make fluorescent tube type table lamp with anodized reflector and square M.S. tubes fixed with flexible joints complete with 9/10 W. fluorescent tube,high density polyester copper wound choke with starter, base condenser and 2m long 3 core round PVC flexible cord with hand shield type 6 A, 3 pin plug top complete.

Each 292 0 292.00

2-2-4 Supplying and erecting plain pendent type bakelite lamp holder complete erected at position with necessary length of twin flexible wire.(upto 1m)

Each 43 8.45 51.00

2-2-5 Supplying and erecting plain pendent type brass lamp holder complete erected at position with 20 cms glass opal shade with necessary length of twin twisted flexible wire 24 / 0.20 mm.(upto1m)

Each 81 8.45 89.00

Page 14: Electrical CSR 12-13

2-2-6 Supplying and erecting Rod Pendent light with 20 mm dia. H.G. screwed conduit of 16 SWG duly painted with ball suspension plate, with glass opal shade complete erected on polished double wooden block with necessary PVC wire leads.

Mtr. 151 13.72 165.00

2-2-7 Supplying and erecting one light Wall bracket fitting with dome complete fixed on the wall.

Each 122 22.17 144.00

2-2-8 Supplying and erecting one light wall bracket MS body & arm Chromium plated/ powder coated complete fixed on wall.

Each 235 22.17 257.00

2-2-9 Supplying and erecting glass shade of suitable size and shape of approved colour and quality on existing decorative fitting

Each 74 14.78 89.00

2-2-10 Supplying and erecting bulkhead fitting suitable for integral CFL fixed on wall. As per specification no.FG-IDF/BHF

Each 164 17.95 182.00

2-2-11 Supplying and erecting bulkhead fitting suitable for non integral CFL , with electronic ballast complete fixed on wall. As per specification no.FG- IDF/BHF

Each 636 17.95 654.00

2-2-12 Supplying and erecting luminaries suitable for 9/13/18 W CFL lamp,fixed on wall above mirror as per specification no.FG-IDF/ML1

Each 433 17.95 451.00

2-2-13 Supplying and erecting 1 light wall bracket Aluminum body & arm anodised / powder coated with decorative glass shade fixed on wall.

Each 239 22.17 261.00

2-2-14 Supplying and erecting spot light / reading light suitable for CFL 5/9/11W complete metal body powder coated / painted with angular movement erected on wooden block and connected.

Each 194 22.17 216.00

2-2-15 Supplying and erecting 2 light wall bracket Aluminum body & arm anodised / powder coated complete with lamp holder and decorative glass shade suitably erected on polished wooden board / plywood pasted with laminate.

Each 323 22.17 345.00

2-2-16 Supplying and erecting 1 light fancy wall bracket with arm fabricated from brass duly lacquered with suitable holder and fancy glass shade duly wired erected on wall with suitable size of polished wooden / laminated board.

Each 420 22.17 442.00

2-2-17 Supplying and erecting 2 light fancy wall bracket with arm fabricated from brass duly lacquered with suitable holder and fancy glass shade duly wired erected on wall with suitable size of polished wooden / laminated board.

Each 658 22.17 680.00

2-2-18 Supplying and erecting Mirror light fitting with 1 x 9 W CFL, with necessary Choke & accessories complete erected on polished wooden / sunmica block as per specification no. FG-IDF/ML2

Each 436 16.89 453.00

2-2-19 Supplying & erecting approved type suspension type decorative pendent fitting single light with anodized aluminium / powder coated MS rod up to 1 m length and canopy on top provided with decorative glass shed duly wired with two core flat wire suitable lamp holder complete.

Each 384 16.89 401.00

2-2-20 Supplying & erecting approved type suspension type decorative fitting with rise /fall arrangement, 1 light inside semi circular metallic reflector with counterweight with guide pulley / spring buffer with work shop type copper flexible wire complete with necessary hook, if required

Each 1397 47.51 1445.00

2-2-21 Supplying and erecting circular type recessed / surface down lighter with reflector and glass cover suitable for CFL 1 x 9 to 18 watts with circular stainless steel ring including Electronic Ballast having pf > 0.98 and holder duly fixed in false ceiling as per specification no. FG -IDF/DL1

Each 724 22.17 746.00

2-2-22 Supplying and erecting square type recessed / surface down lighter with reflector and glass cover suitable for CFL 1 x 9 to 18W with square type stainless steel border including electronic ballast and holder duly fixed in false ceiling as per specification no. FG-IDF/DL1

Each 1051 22.17 1073.00

2-2-23 Supplying and erecting circular type recessed / surface down lighter with reflector and glass cover suitable for CFL 2 x 9 to 18 watts with circular stainless steel ring including Electronic Ballast having pf > 0.98 and holder duly fixed in false ceiling as per specification no. FG -IDF/DL1

Each 984 22.17 1006.00

2-2-24 Supplying and erecting square type recessed / surface down lighter with reflector and glass cover suitable for CFL 2 x 9 to 18W with square type stainless steel border including Electronic Ballast having pf > 0.98 and holder duly fixed in false ceiling as per specification no. FG-IDF/DL1

Each 1552 22.17 1574.00

2-2-25 Supplying and erecting square/ circular type recessed / surface down lighter with glass cover suitable for CFL 2x18W including gear box, fixed in false ceiling as per specification no.FG-IDF/DL1

Each 999 22.17 1021.00

2-2-26 Supplying and erecting approved make recessed / surface down lighter with mirror optics of 100 mm suitable for 1 x 9 to 18 W compact flou. Lamp, fixed in false ceiling as per specification no.FG- IDF/MOF

Each 619 22.17 641.00

2-2-27 Supplying and erecting approved make recessed / surface down lighter with mirror optics of 100 mm suitable for 2 x 9 to 18 W compact flou. lamp fixed in false ceiling as per specification no.FG- IDF/MOF

Each 1100 22.17 1122.00

2-2-28 Supplying and erecting approved make recess / surface mirror optic fitting suitable for 2 x 36W compact fluo.lamp fixed in false ceiling/ on ceiling as per specification no. FG-IDF/MOF

Each 1753 29.56 1783.00

Page 15: Electrical CSR 12-13

2-2-29 Supplying and erecting approved make recess / surface soft light mirror optic square / rectangular fitting suitable for 2 x 36W compact fluo.lamp with PL Wings with Electronic Ballast having pf > 0.98 & THD <10 fixed in false ceiling / on ceiling as per specification no. IDF/MOF

Each 3219 29.56 3249.00

2-2-30 Supplying and erecting approved make recess / surface soft light square / rectangular PL fitting suitable for 2 x 36W compact fluo.lamp with Electronic Ballast having pf > 0.98 & THD <10 fixed in false ceiling / on ceiling as per specification no. FG-IDF/MOF

Each 2362 29.56 2392.00

2-2-31 Supplying and erecting approved make square double parabolic recess / surface mirror optic square / rectangular PL fitting suitable for 2 x 36W compact fluo.lamp with Electronic Ballast having pf > 0.98 & THD <10 fixed in false ceiling / on ceiling as per specification no. IDF/MOF

Each 2580 29.56 2610.00

2-2-32 Supplying and erecting approved make square parabolic recess / surface mirror optic square / rectangular PL fitting suitable for 3 x 36 watt compact fluo.lamp with Electronic Ballast having pf > 0.98 & THD <10 fixed in false ceiling / on ceiling as per specification no. FG-IDF/MOF

Each 3242 29.56 3272.00

2-2-33 Supplying and erecting approved make Crescent recess / surface soft light mirror optic square PL fitting suitable for 3 x 36W compact fluo.lamp with Electronic Ballast having pf > 0.98 & THD <10 fixed in false ceiling / on ceiling as per specification no. FG-IDF/MOF

Each 3300 29.56 3330.00

2-2-34 Supplying and erecting 1 x 9 to 18W PL with electronic ballast concealed type foot light having CRCA powder coated body and alluminium step type or mirror finish reflector covered with clear acrylic stainless steel mat finish frame ( 9x6 inch in size) as per specification no. FG-IDF/FL

Each 1859 29.56 1889.00

2-2-35 Supplying & erecting approved make 1 x T8 40/36W white stove enamelled / powder coated box type fluo.fitting with 40 Watts. polyester heavy duty copper wound ballast, fixed at ceiling or on wall as per specification no.FG-IDF/BFF

Each 588 17.95 606.00

2-2-36 Supplying & erecting approved make 1 x T8 40/36 watt white stove enamelled / powder coated box type fluo.fitting with 40 Watts. Electronic ballast pf > 0.98 & THD <10 , fixed at ceiling or on wall. As per specification no.FG-IDF/BFF

Each 695 17.95 713.00

2-2-37 Supplying & erecting approved make 1 x T8 40/36W white stove enamelled / powder coated box type fluo. fitting with 40 W Vaccum impregnated LOW WATT LOSS BALLAST fixed at ceiling or on wall as per specification no.FG-IDF/BFF

Each 760 17.95 778.00

2-2-38 Supplying & erecting 1x28W T-5 Energy Efficient Retrofit/ Stand alone Fluorescent Tube light Fitting (EETLF) box type complete with Electronic Ballast having pf > 0.98 & THD <10 and lamp holders duly wired ready to use for 230 Volts, 50 Hz. Single phase AC Supply to IS: 10322 as per quality requirements and erected on varnished wooden blocks with flexible wire twin core 24/0,2mm.and marking Sr. No. and date of erection.

Each 1075 17.95 1093.00

2-2-39 Supplyng & erecting 1x 36W T-8 Energy Efficient Fluorescent tube light fitting EETLF slim type with clear acrylic cover and endcaps Minolta type with Electronic Ballast having pf > 0.98 & THD <10 and lamp holders duly wired ready to use for 230 Volts, 50 Hz. Single phase AC Supply to IS: 10322 as per quality requirements and erected on varnished wooden blocks with flexible wire twin core 24/0, 2mm. & and marking Sr. No. and date of erection.

Each 1998 17.95 2016.00

2-2-40 Supplying and erecting approved make white stove enamelled / powder coated CRCA sheet not less than 0.7 mm thick chalk board type fluo.fitting of 1 xT8 40/36W with 40 Watts VPIT ballast, fixed at ceiling or on wall as per specification No.FG-IDF/CBF

Each 1480 17.95 1498.00

2-2-41 Supplying and erecting approved make white stove enamelled / powder coated CRCA sheet not less than 0.7 mm thick chalk board type fluo.fitting of 1 xT8 40/36 W.with 40 Watts Electronic Ballast having pf > 0.98 & THD <10 , fixed at ceiling or on wall as per specification no. FG- IDF/CBF

Each 1596 17.95 1614.00

2-2-42 Supplying and erecting approved make 2 x T8 40/36W.white stove enamelled / powder coated box type fluo.fitting with 2 x 40 W.VPIT copper ballasts, fixed at ceiling or on wall as per specification No. FG- IDF/BFF

Each 1133 17.95 1151.00

2-2-43 Supplying and erecting approved make 2 x T8 40/36W.white stove enamelled / powder coated box type fluo.fitting with 2x 40W Electronic Ballast having pf > 0.98 & THD <10 , fixed at ceiling or on wall as per specification No. FG-IDF/BFF

Each 1329 17.95 1347.00

2-2-44 Supplying & erecting approved make 1 x T8 40/36W with white stove enamelled/ powder coated industrial type flou. fitting with one 40W Electronic Ballast having pf > 0.98 & THD <10 , fixed at ceiling or on wall as per specification No. FG-IDF/INF

Each 1190 17.95 1208.00

Page 16: Electrical CSR 12-13

2-2-45 Supplying & erecting approved make 2 x T8 40/36W with white stove enamelled/ powder coated industrial type flou. fitting with two 40 W Electronic Ballast having pf > 0.98 & THD <10 , fixed at ceiling or on wall as per specification No. FG-IDF/INF

Each 1590 17.95 1608.00

2-2-46 Supplying and erecting approved make 1 xT8 40/36W fluo fitting recess /surface mounting mirror optic type with one 40W Electronic Ballast having pf > 0.98 & THD <10 , fixed in false ceiling or at ceiling or on wall as per specification No. FG-IDF/MOP

Each 1538 29.56 1568.00

2-2-47 Supplying and erecting approved make 2 xT8 40/36 Watt fluo fitting recess /surface mounting mirror optic type with two 40 W Electronic Ballast having pf > 0.98 & THD <10 , fixed in false ceiling or at ceiling or on wall as per specification No. FG-IDF/MOP

Each 2233 29.56 2263.00

2-2-48 Erection of Departmentally supplied fitting on PVC block connected with necessary leads for 4’40 Watts. fitting and 2’20 W. fitting and with marking the sr. no. & date of erection.

Each 17 17.95 35.00

2-2-49 Erection of Departmentally supplied surface/recess type decorative fitting with CFL on PVC block connected with necessary leads

Each 17 22.17 39.00

2-2-50 Erection of Departmentally supplied mirror optic type fitting on PVC block connected with necessary leads and with marking the Sr. No. & date of erection.

Each 21 29.56 51.00

2-2-51 (New)

Supplying and erecting approved make square / rectangular recess / surface mirror optic PL fitting with para louvers suitable for 1 x 36W compact fluo.lamp with electronic ballast pf > 0.98 & THD <10 fixed in false ceiling / on ceiling as per specification no. FG-IDF/MOF

Each 1228 29.56 1258.00

Note :- 1) Reduce Rs 10/- if, fitting is to be erected on provided wooden / Sunmica board for Item No 2-2-11 to 2-2-18 2) Use of fluo. Fitting with conventional choke shall be avoided. 3) All fittings are excluding tubes/lamps. 4) All 40W fitings are suitable for 40W / 36 W - conventional/slim T8 (High Phosphor 2450 lumens) & Energy Efficient 36 W T8(Tri-band Phosphor 3250 lumens). 5) The fitting having two or more CFL/ FTL should be provided with independent choke for each tube/ bulb

2.3 Out door Fittings (FG-ODF) 2-3-1 Supplying and erecting CFL Street light Suitable for one No. 9 to

18W CFL lamp with electronic ballast having pf > 0.98 & THD <10 on provided bracket as per specification no. FG-ODF/CSL

Each 788 51.73 840.00

2-3-2 Supplying and erecting CFL Street light Suitable for two Nos. 9 to 18W CFL lamp with electronic ballast having pf > 0.98 & THD <10 on provided bracket as per specification no. FG-ODF/CSL

Each 984 51.73 1036.00

2-3-3 Supplying and erecting CFL Street light Suitable for one No. 36W CFL lamp with electronic ballast having pf > 0.98 & THD <10 provided bracket as per specification no. FG-ODF/CSL

Each 1112 51.73 1164.00

2-3-4 Supplying and erecting CFL Street light Suitable for two Nos. 36W CFL lamp with two individuals electronic ballast having pf > 0.98 & THD <10 on provided bracket as per specification no. FG-ODF/CSL

Each 1968 516.24 2484.00

2-3-5 Supplying and erecting CFL Street light Suitable for four Nos. 36W CFL lamp with four individuals electronic ballast having pf > 0.98 & THD <10 on provided bracket as per specification no. FG-ODF/CSL

Each 3793 51.73 3845.00

2-3-6 Supplying and erecting Energy efficient street light fitting Suitable for 2 x 14W T-5 lamp with PF > 0.98 & THD <10 The fitting canopy is made of deep drown Alluminium body provided with serrated acrylic diffuser and gasket as per specification no. FG-ODF/FLS2

Each 2432 51.73 2484.00

2-3-7 Supplying and erecting Energy efficient T 5 Street light Suitable for 2 x 24W T 5 lamp with PF > 0.98.& THD <10 The fitting canopy is made of deep drownAlluminium body provided with serrated acrylic diffuser and gasket as per specification no. FG-ODF/FLS2

Each 2200 51.73 2252.00

2-3-8 Supplying and erecting Energy efficient T 5 Street light Suitable for 4 x 24W T 5 lamp with PF > 0.98.& THD <10 The fitting canopy is made of deep drown Alluminium body provided with serrated acrylic diffuser and gasket as per specification no. FG-ODF/FLS2

Each 5268 51.73 5320.00

2-3-9 Supplying and erecting 80 / 125W water tight M. V. lamp fitting on provided bracket as per specification no. FG-ODF/GSL

Each 1988 109.79 2098.00

2-3-10 Supplying and erecting 250W water tight M. V. lamp fitting on provided bracket as per specification no. FG-ODF/GSL

Each 2924 185.8 3110.00

2-3-11 Supplying and erecting 400W water tight M. V. lamp fitting on provided bracket as per specification no. FG-ODF/GSL

Each 3479 185.8 3665.00

2-3-12 Supplying & erecting street light 70W H.P. S.V. lamp fitting on provided bracket as per specification no. FG-ODF/GSL

Each 2113 267.09 2380.00

2-3-13 Supplying & erecting street light 150W H.P.S.V. lamp fitting on provided bracket as per specification no. FG-ODF/GSL

Each 3041 267.09 3308.00

2-3-14 Supplying & erecting street light 250W H.P.S.V. lamp fitting on provided bracket as per specification no. FG-ODF/GSL

Each 3333 311.43 3644.00

2-3-15 Supplying & erecting Flood light Luminaries suitable for 70W metal halide lamp on provided bracket as per specification no. FG-ODF/GFL

Each 2807 171.02 2978.00

Page 17: Electrical CSR 12-13

2-3-16 Supplying & erecting Flood light Luminaries suitable for 150W metal halide lamp on provided bracket as per specification no. FG-ODF/GFL

Each 3275 185.8 3461.00

2-3-17 Supplying & erecting high purity sheet aluminum flood light fitting suitable for 250/400W, MV/SV lamp on provided bracket as per specification no. FG-ODF/GFL

Each 3696 124.57 3821.00

2-3-18 Supplying & erecting flood light luminaire suitable for 1 x 500 Watts Halogen lamp. on provided bracket as per specification no. FG-ODF/GFL

Each 889 59.12 948.00

2-3-19 Supplying & erecting flood light luminaire suitable for 1 x1000W Halogen lamp. on provided bracket as per specification no. FG-ODF/GFL

Each 1356 84.46 1440.00

2-3-20 Supplying & erecting street light metal halide lamp fitting 70W on provided bracket as per specification no. FG-ODF/GSL

Each 2222 171.02 2393.00

2-3-21 Supplying & erecting street light metal halide lamp fitting 150W on provided bracket as per specification no. FG-ODF/GSL

Each 3210 171.02 3381.00

2-3-22 Supplying & erecting street light metal halide lamp fitting 250W on provided bracket as per specification no. FG-ODF/GSL

Each 3561 207.97 3769.00

2-3-23 Supplying & erecting street light metal halide lamp fitting 400W on provided bracket as per specification no. FG-ODF/GSL

Each 3333 207.97 3541.00

2-3-24 Supplying & erecting flood light metal halide lamp fitting 2x250W on provided bracket as per specification no. FG-ODF/GFL

Each 6081 465.56 6547.00

2-3-25 Supplying & erecting flood light metal halide lamp fitting 250W on provided bracket as per specification no. FG-ODF/GFL

Each 3625 207.97 3833.00

2-3-26 Supplying & erecting integral post top lantern fixture similar to JUNO type for 70 Watts HPSV lamp consisting of brown painted LM 6 alloy cylindrical spigot,decorative acrylic bowl supported by spun aluminum top cover complete with accessories such as copper wound choke and condensor housed within the lantern with necessary wiring etc.

Each 4362 520.46 4882.00

2-3-27 Supplying & erecting integral post top lantern fixture similar to JUNO type for 3x70W HPSV lamp consisting of brown painted LM 6 alloy cylindrical spigot,decorative acrylic bowl supported by spun aluminum top cover complete with accessories such as copper wound choke and condensor housed within the lantern with necessary wiring. The three nos of Juno fittings are to be provided with centre pole mounting pipe assembly and with 3 nos “ J “ piple bracket.

Each 24278 520.46 24798.00

2-3-28 Supplying & erecting integral post top lantern fixture similar to JUNO type for 70W MH lamp consisting of brown painted LM 6 alloy cylindrical spigot,decorative acrylic bowl supported by spun aluminum top cover complete with accessories such as copper wound choke and condensor housed within the lantern with necessary wiring etc.

Each 4362 520.46 4882.00

2-3-29 Supplying & erecting integral post top lantern fixture similar to JUNO type for 3x70 Watts MH lamp consisting of brown painted LM 6 alloy cylindrical spigot,decorative acrylic bowl supported by spun aluminum top cover complete with accessories such as copper wound choke and condensor housed within the lantern with necessary wiring The three nos of Juno fittings are to be provided with centre pole mounting pipe assembly and with 3 nos “ J “ piple bracket.

Each 24278 520.46 24798.00

2-3-30 Supplying & erecting integral post top lantern fixture similar to JUNOtype for 150W MH lamp consisting of brown painted LM 6 alloy cylindricalspigot,decorative acrylic bowl supported by spun aluminum top covercomplete with accessories such as copper wound choke and condensor housed within the lantern with necessary wiring etc.

Each 7531 520.46 8051.00

2-3-31 Supplying & erecting integral post top lantern fixture similar to JUNO type for 3x150W MH lamp consisting of brown painted LM 6 alloy cylindrical spigot,decorative acrylic bowl supported by spun aluminum top cover complete with accessories such as copper wound choke and condensor housed within the lantern with necessary wiring The three nos of Juno fittings are to be provided with centre pole mounting pipe assembly and with 3 nos “ J “ piple bracket.

Each 24816 520.46 25336.00

2-3-32 Supplying & erecting gate/ garden light fitting with 300 mm dia. glass bowl on provided pipe as per specification no. FG-ODF/GLT

Each 918 83.4 1001.00

2-3-33 Supplying & erecting gate light fitting with 200 mm dia. glass bowl suitable for one 9 / 11W CFL lamp on provided pipe as per specification no. FG- ODF/GLT

Each 349 83.4 432.00

2-3-34 Supplying & erecting garden light fitting with 300 mm. dia.clear acrylic bowl / mushroom / round shape with bollard suitable for one 9 / 11W CFL lamp on provided pipe as per specification no. FG-ODF/GLT

Each 1579 76.01 1655.00

2-3-35 Supplying & erecting gate light fitting with 300 mm. dia.Opal acrylic bowl / mushroom / round shape without bollard suitable for one 9 / 11W CFL lamp on provided pipe as per specification no. FG-ODF/GLT

Each 723 76.01 799.00

2-3-36 Erecting the departmentally supplied W.P. street light fitting and marking / painting the Sr. No. and date of erection by best quality enamel paint.

Each 0 55.95 56.00

2-3-37 Erecting Deptt. supplied H.PS.V/ H.P.M.V/ M.H. Fitting of 70-150W marking/ painting Sr. No. & date of erection by best quality enamel paint

Each 0 109.79 110.00

2-3-38 Erecting the Deptt. supplied H.PS.V./ H.PM.V./M.H fitting of 250 – 400W and marking/ painting Sr. No. & date of erection by best quality enamel paint

Each 0 54.9 55.00

2-3-39 (New)

Supplying and erecting Energy efficient street light fitting Suitable for 4 x 14W T-5 lamp with PF > 0.98 & THD <10 The fitting canopy is made of deep drown Alluminium body provided with serrated acrylic diffuser and gasket as per specification no. FG-ODF/FLS2

Each 5310 54.9 5365.00

Page 18: Electrical CSR 12-13

Note :- 1) If (DPSD) energy saving device is used, increase rate by Rs 800/- for one lamp in each fitting. 2) All fittings are excluding tubes/lamps. 3) The fitting having two or more CFL/ FTL should be provided with independent choke for each tube/ bulb 4) All SV/MV/MH/CFL/T-5 street fittings shall be used with one piece enclosure with top opening

2.4 Accessories (FG-AS) 2-4-1 Supplying and erecting condensor 4 microfarad for fluo. Fitting, as per

specification No FG-FG/AS7Each 41 6.33 47.00

2-4-2 Supplying and erecting condensor for M.V. lamp 125 W, 230 V as per specification No FG-FG/AS7

Each 220 22.17 242.00

2-4-3 Supplying and erecting condensor for M.V. lamp 250 W, 230 V as per specification No: FG-FG/AS7

Each 245 22.17 267.00

2-4-4 Supplying and erecting condensor for M.V. lamp 400 W, 230 V as per specification No: FG-FG/AS7

Each 330 22.17 352.00

2-4-5 Supplying and erecting ignitor suitable for 230 V H.P.S.V. lamps 70 / 150/250/400W as per specification No: FG-FG/AS6

Each 175 17.95 193.00

2-4-6 Supplying and erecting electronic ignitor suitable for Metal hallide Lamp70 / 150 /250 /400 Watts (Integral/non-integral type luminaries) as per specification No: FG-FG/AS6

Each 245 17.95 263.00

2-4-7 Supplying and erecting low watt loss vacuum impregnated copper choke (VPIT) suitable for CFL / FTL from 11-20 W as per specification No. FG- FG/AS1

Each 162 17.95 180.00

2-4-8 Supplying and erecting low watt loss vacuum impregnated copper choke (VPIT) suitable for CFL / FTL from 24-40 W as per specification No. FG- FG/AS1

Each 226 17.95 244.00

2-4-9 Supplying and erecting VPIT heavy duty copper wound ballast 230 V for 80 -150 W, HV/ M.V./ MH lamp as per specification No. FG-FG/AS5

Each 710 17.95 728.00

2-4-10 Supplying and erecting VPIT compound heavy duty copper wound ballast for 230V 250 W HV/ M.V./ MH lamp as per specification No. FG-FG/AS5

Each 1149 20.06 1169.00

2-4-11 Supplying and erecting VPIT heavy duty copper wound ballast for 230V 400 W HV/ M.V./ MH. lamp as per specification No.FG-FG/AS4

Each 1550 20.06 1570.00

2-4-12 Supplying 18 / 20 /36 / 40 W tube starter 230 V as per specification No. FG- FG/AS11

Each 11 0 11.00

2-4-13 Supplying and erecting double suspension heavy duty lacquered iron chain with hooks for erecting fluo.tube light fitting with necessary 2 or 3 core copper flexible wire 24/.2 mm for connecting leads.(for measurements half of the actual length used)

Mtr. 23 5.28 28.00

2-4-14 Supplying and erecting double suspension pipe rod of 16 gauge 20mm.dia H.G.conduit duly threaded and painted with two coats of enamel paint for erection of fluo tube light fitting with necessary check nuts and 2 or 3 core copper flexible wire of 24/.2 mm for connecting leads (for measurements half of the actual length both pipes used)

Mtr. 136 10.56 147.00

2-4-15 Supplying and erecting ball suspension plate cast aluminum erected with spring on wooden block in position.

Each 17 5.28 22.00

2-4-16 Supplying and erecting electronic ballast pf > 0.98 & THD <10 of approved make having operating range100 to 300V with surge supression not less than 9 kV and with RF filter conforming to IS 13021 (Part I) suitable for T 8, 1x40/1x36W Fluo. tube fitting.

Each 269 20.06 289.00

2-4-17 Providing and erecting clamps for box type / industrial type fittings with provided suspension down rod of 20 mm dia. H.G.conduit,the clamp shall be made of 25 x 3 mm MS flat with cutting,bending,drilling erected properly with necessary nut bolt as per direction.

Pair 52 10.56 63.00

Note :- The item shall be provided only at the time of installation of fitting on trusses / pipe / angle / channel.

2-4-18 Supplying and erecting Bakelite call bell with 6 cm / buzzer with double coil suitable for 230V complete erected on PVC block.

Each 41 13.72 55.00

2-4-19 Supplying and erecting gong with double coil suitable for 230V. complete erected on polished wooden block.

Each 50 13.72 64.00

2-4-20 Supplying and erecting Ding Dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.

Each 82 13.72 96.00

2-4-21 Supplying and erecting luminous / modular type call bell indicator with plastic body, heavy duty coil and indicator lamp working on 230V A.C. supply with resetting arrangement complete erected on double wooden/ sunmica board.

Each 179 13.72 193.00

2-4-22 Supplying and erecting Electronic Type cordless call bell erected on T.W. board having portable bell push working on 9 V. D.C. and bell on 250 V A.C. supply. (Effective range upto 45 meter)

Each 453 8.45 461.00

Note :- Reduce Rs. 10/- if accessories to be erected on provided wooden / sunmica board for item no.2.4.25 to 2.4.29

Page 19: Electrical CSR 12-13

2-4-23 Supplying and fixing wiremesh(Jali) cover suitable for fitting / fan or for any purpose, complete with necessary materials. The Jali cover shall be made from good quality G.I. wire mesh size 25 mm x 25 mm and made up of 14 SWG G.I. wire with side / supporting MS strips of suitable size.

Sqm. 398 65.45 463.00

Note :- The fitting having two or more CFL/ FTL should be provided with independent choke for each tube/ bulb

2-4-24 (New)

Supplying and erecting Electronic ballast having pf > 0.98 & THD <10 orTransformer suitable for CFL / FTL from 11-28 W as per specificationNo. FG-FG/AS1

Each 214 20.06 234.00

2-4-25 (New)

Supplying and erecting Electronic ballast pf > 0.98 & THD <10 or Transformer suitable for CFL / FTL from 30-40 W as per specification No. FG-FG/AS1

Each 341 20.06 361.00

2.5 Bracket for Outdoor Fittings (FG-BKT) 2-5-1 Supplying and erecting street light bracket made from 25 mm dia B class G.I. Pipe

0.6 m in length along with pole cap of 300 mm length and 80mm dia duly welded with provided leads as per specification No FG- BKT/ BPC

Each 392 85.51 478.00

2-5-2 Supplying and erecting street light bracket made from 40 mm. dia B class G.I. pipe,0.6 m. in length along with pole cap of 300 mm length and 80mm dia duly with provided leads as per specification No FG- BKT/ BPC

Each 428 85.51 514.00

2-5-3 Supplying and erecting street light Wall bracket made from 25 mm. dia ‘B’ class G.I. pipe 1.2 m in total length complete as per specification no. FG-BKT/WB

Each 364 64.4 428.00

2-5-4 Supplying and erecting street light Wall bracket made from 40 mm. dia ‘B’ class G.I. pipe 1.2 m in total length complete as per specification no. FG-BKT/WB

Each 492 64.4 556.00

2-5-5 Supplying and erecting street light bracket for single fitting made from 40 mm. dia B class G.I. pipe,1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no FG- BKT/ BPC

Each 697 85.51 783.00

2-5-6 Supplying and erecting street light bracket for double fitting made from 40 mm. dia B class G.I. pipe,1.0 m. in length along with pole cap of 300 mm length, 100 mm dia duly welded as per specification no FG- BKT/ BPC

Each 1001 85.51 1087.00

2-5-7 Supplying and erecting street light bracket for erection of single fitting on tubular welded pole with 40 mm. dia 1.0 m. long B grade G.I. pipe along with pole cap of 125 mm dia. 600 mm long duly welded as per specification no FG- BKT/ BPC

Each 1163 115.07 1278.00

2-5-8 Supplying and erecting street light bracket for erection of double fitting on tubular welded pole with 40 mm. dia 1.0 m. long on each side B grade G.I. pipe welded to pole cap of 125 mm dia. 600 mm long as per specification no FG- BKT/ BPC

Each 1483 115.07 1598.00

2-5-9 Supplying and erecting Street light bracket for erection of side entry fitting on pole with 40 mm. dia. 'B' grade G.I. pipe of required length complete as per specification no. FG- ODF/ SLB.

Mtr. 430 57.01 487.00

2-5-10 Supplying and erecting Street light bracket for erection of side entry fitting on pole with 25 mm. dia. 'B' grade G.I. pipe of required length complete as per specification no. FG- ODF/ SLB.

Mtr. 325 57.01 382.00

2.6 Fans (FG-FN) 2-6-1 Supplying and erecting Ceiling fan of 600 mm. sweep complete erected in position

as per specifcation no. FG-FN/CFEach 1576 30.62 1607.00

2-6-2 Supplying and erecting Ceiling fan of 900 mm. sweep complete erecte in position as per specifcation no. FG-FN/CF

Each 1602 31.67 1634.00

2-6-3 Supplying and erecting Ceiling fan of 1200 mm. sweep complete erected in position as per specifcation no. FG-FN/CF

Each 1535 31.67 1567.00

2-6-4 Supplying and erecting Ceiling fan of 1400 mm. sweep complete erected in position as per specifcation no. FG-FN/CF

Each 1697 31.67 1729.00

2-6-5 Providing and erecting bracket fan 400 mm. sweep A. C. 230 volts 50 cycles 1350 R.P.M. Oscillating type, plastic or metal blades chrome plated guard with regulator and moisture proof treatment to winding and with ‘E’ class insulation and marking Sr. No. and date of erection.

Each 2225 90.79 2316.00

2-6-6 Providing and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 RPM without speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 Volts single phase, 50 cycles A.C. supply, with one metre of 3 core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation and marking Sr. No. and date of erection.

Each 5417 98.18 5515.00

2-6-7 Providing and erecting air circulator 600 mm. sweep oscillating type, wallmounting 1440 RPM without speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 Volts single phase, 50 cycles A.C. supply, with one metre of 3 core lead wire and withmoisture proof treatment to winding and with ‘E’ class insulation and marking Sr. No. and date of erection.

Each 6967 193.19 7160.00

2-6-8 Supplying Pedestal fan 400 mm. 230 Volts 50 cycles oscillating type complete with guard and regulator 3 mtrs. of flexible wire and hand shield type 3 pin plug top and marking Sr. No. and date of erection.

Each 2573 0 2573.00

Page 20: Electrical CSR 12-13

2-6-9 Supplying pedestal type air circulator 450 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM with speed regulator,overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 metre length and Hand Shield type 3 pin 5A. plug topcomplete with moisture proof treatment and ‘E’ class insulation andmarking Sr. No. and date of erection.

Each 5729 0 5729.00

2-6-10 Supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM with speed regulator,overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 metre length and Hand Shield type 3 pin 6A. plug top complete with moisture proof treatment and ‘E’ class insulation and marking Sr. No. and date of erection.

Each 7366 0 7366.00

2-6-11 Supplying Table fan of A.C. 230 V. 50 cycles 400 mm. oscillating type complete with 2 mtrs. of 3 core flexible wire and Hand shield type 3 pin plug top and marking Sr. No. and date of erection.

Each 1860 0 1860.00

2-6-12 Supplying and erecting cabin fan of A.C. 230 V. 50 cycles 250 mm. /300 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc and marking Sr. No. and date of erection.

Each 1659 25.34 1684.00

2-6-13 Supplying and erecting cabin fan of A.C. 230 V. 50 cycles 375 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc and marking Sr. No. and date of erection.

Each 1763 24.28 1787.00

For all type of fans except ceilling fan the metal canopy shall be provided. 2-6-14 Supplying and erecting fresh air cum Exhaust fan of light duty 250 V

A.C. 50 cycles 300mm. 1400 RPM metallic body, plastic blades, wire mesh, duly erected in an approved manner and marking Sr. No. and date of erection.

Each 1542 25.34 1567.00

2-6-15 Supplying and erecting fresh air cum Exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM metallic body, plastic blades, wiremesh, duly erected in an approved manner and marking Sr. No. and date of erection.

Each 1430 24.28 1454.00

2-6-16 Supplying and erecting Exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400RPM with condensor complete erected in position with necessary materials. Fanmotor with moisture proof treatment and ‘E’ class insulation and marking Sr. No. & date of erction.

Each 1404 49.62 1454.00

2-6-17 Supplying and erecting Exhaust fan heavy duty 230 V, A.C. 50 cycles 375 mm. 900 RPM complete erected in position as per specifcation no. FG- FN/EXF

Each 3519 84.46 3603.00

2-6-18 Supplying and erecting Exhaust fan heavy duty 230 V A.C. 50 cycles 375 mm. 1400 RPM complete erected in position as per specifcation no. FG- FN/EXF

Each 3573 78.12 3651.00

2-6-19 Supplying and erecting Exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM complete erected in position as per specifcation no. FG- FN/EXF

Each 4981 78.12 5059.00

2-6-20 Supplying and erecting Exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 900 RPM complete erected in position as per specifcation no. FG-FN/EXF

Each 4690 78.12 4768.00

2-6-21 Supplying and erecting Exhaust fan heavy duty 440 V A.C. 50 cycles 900 RPM 375 mm complete erected in position as per specifcation no. FG -FN/EXF

Each 4013 78.12 4091.00

2-6-22 (New)

Supplying and erecting Five Star Rated Energy Saving Ceiling Fan 440 V A.C. 50 cycles 1200 mm complete erected in position as per specifcatio no. FG-FN/CF

Each 2274 33.78 2308.00

2.7 Accessories for Fans (FG-FAS) 2-7-1 Supplying and erecting condenser 2.5 micro farad for ceiling fan Each 29 6.33 35.00 2-7-2 Supplying & fixing Anchor type fastener Fan hook, with 2 Nos of 10 mm

dia x 75 mm long with necessary materials for Ceiling Fan.Each 59 9.5 69.00

2-7-3 Supplying and erecting fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted.

Each 140 13.72 154.00

2-7-4 Supplying and erecting Fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.

Each 56 23.23 79.00

2-7-5 Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalentsquare size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected inposition and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.

Each 105 20.06 125.00

2-7-6 Supplying and erecting ‘B’ grade G.I.pipe/M.S. pipe down rod duly painted for fan complete erected with PVC two core flexible cable 24/0.2 mm copper PVC wire.

Mtr. 135 7.39 142.00

Note :- For ceiling fans the extra down rod shall be provided only if the roof / slab height is more than 4.0 m

0 3.17 3.00

2-7-7 Erection of departmentally supplied ceiling fan with necessary materials,and marking / painting the Sr. No. and date of erection by best quality enamel paint.

Each 11 31.67 43.00

Page 21: Electrical CSR 12-13

2-7-8 Erection of departmentally supplied Exhaust fan with necessary materials, and marking / painting the Sr. No. and date of erection by best quality enamel paint.

Each 39 125.63 165.00

2-7-9 Supplying and erecting, resistance type regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided T.W. block.

Each 67 9.5 77.00

2-7-10 Supplying and erecting electronic type 600 W. dimmer/speed controller complete erected on provided switch board.

Each 139 9.5 149.00

2-7-11 Supplying and erecting electronic type 300/450 W dimmer/speed controller complete erected on provided switch board.

Each 116 9.5 126.00

2-7-12 Supplying and erecting electronic type step regulator complete erected on provided switch board.

Each 190 9.5 200.00

2-7-13 Providing recess in brick wall suitable for erection of exhaust fan up to 450mm sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 150 mm

Each 78 125.63 204.00

2-7-14 Providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm

Each 94 141.46 235.00

2-7-15 Providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 375 mm.

Each 122 188.97 311.00

2-7-16 Providing recess in brick wall suitable for erection of exhaust fan up to 450mm sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the stone wall.

Each 133 282.93 416.00

2-7-17 Supplying & erecting 22 guage G.I sheet metal CAWL sector shaped with 25 mm x 25mm x 3mm angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC

Each 818 51.73 870.00

2-7-18 Supplying & erecting 22 guage G.I sheet metal CAWL sector shaped with 25 mm x 25mm x 3mm angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 400 mm as per specification no FG-FAS/MSC

Each 935 60.17 995.00

2-7-19 Supplying & erecting 22 guage G.I sheet metal CAWL sector shaped with 25 mm x 25mm x 3mm angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 450 mm as per specification no FG-FAS/MSC

Each 993 60.17 1053.00

2-7-20 Supplying & erecting 20 guage G.I sheet metal CAWL rectangular / round shaped with 25 mm x 25mm x 3mm angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC

Each 812 40.12 852.00

2-7-21 Supplying & erecting 20 guage G.I sheet metal CAWL rectangular / round shaped with 25 mm x 25mm x 3mm angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 400 mm as per specification no FG-FAS/MSC

Each 1081 40.12 1121.00

2-7-22 Supplying & erecting 20 guage G.I sheet metal CAWL rectangular / round shaped with 25 mm x 25mm x 3mm angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 450 mm as per specification no FG-FAS/MSC

Each 1110 40.12 1150.00

Note:- 1) Reduce overall rate by 20% for item no 2.7.16 to 2.7.21, if separate angle iron is provided. 2)Before erection , accessories such as hook,shackle,nuts,bolts, U clamps,quater pin,down rod & checknuts shall be checked thorougly for its quality.

2.8 Dismantling 2-8-1 Dismantling of existing fluorescent fittings of any type & size. Each 0 7.39 7.00 2-8-2 Dismantling the existing W.T.fluoroscent fitting / S.V./ M.V/MH. lamp

fitting from wall with brackets and making the site as original complete.Each 0 20.06 20.00

2-8-3 Dismantling the existing W.T. fluorescent fitting/ S.V./ M.V/MH lamp fitting from pole with brackets complete.

Each 0 61.23 61.00

2-8-4 Dismantling the existing ceiling fan/exhaust fan/cabin fan/bracket fan complete with accessories, G.I. down rod, frame etc. and making the site clear.

Each 0 20.06 20.00

Note :- The rates for item no 2.8.1 to 2.8.4 are for dismantling and handing over to section office inclusive of transportation upto 25 km, between site and section office.

Chapter 3 : APPLIANCES (AP)

3.1 Water Heaters (WH) 3-1-1 Supplying and erecting storage type Horizontal / vertical water heater 15

Liters capacity with high impact resistance Engineering plastic body on wall / loft as per specification No. AP-WH/STWH

Each 9124 233.31 9357.00

3-1-2 Supplying and erecting storage / pressure type Horizontal / vertical water heater 25 Liters of mild steel body, on wall / loft as per specification No. AP-WH/STWH

Each 8269 233.31 8502.00

Page 22: Electrical CSR 12-13

3-1-3 Supplying and erecting storage type Horizontal / vertical water heater 25 Liters capacity with high impact resistance Engineering plastic body on wall / loft as per specification no. AP-WH/STWH

Each 10103 233.31 10336.00

3-1-4 Supplying and erecting storage/ pressure type vertical / horizontal water heater 35 Liters of mild steel body on wall / loft as per specification No. AP-WH/STWH

Each 10979 266.04 11245.00

3-1-5 Supplying and erecting storage type Horizontal / vertical water heater 35 Liters capacity with high impact resistance Engineering plastic body on wall / loft as per specification no. AP-WH/STWH

Each 10951 266.04 11217.00

3-1-6 Supplying and erecting storage/ pressure type vertical / horizontal water heater 50 Liters capacity of mild steel body on wall / loft as per specification No. AP-WH/STWH

Each 13058 266.04 13324.00

3-1-7 Supplying and erecting storage type Horizontal / vertical water heater 50 Liters capacity with high impact resistance Engineering plastic body on wall / loft as per specification no. AP-WH/STWH

Each 11882 266.04 12148.00

3-1-8 Supplying and erecting ISI mark midget type 3.0 Ltr instant type water heater of ABS plastic body 3 kW compling IS3412 of 1994 heating element 230/250 Volts 50 Cycle A.C. supply with inlet and outlet, thermostatic control and thermal cutoff with 3 core PVC flexible wire leads duly tested and marking Sr. No. and date of erection.

Each 3800 35.89 3836.00

3-1-9 Supplying and erecting Chromium plated heavy duty brass stop cock for inlet pipe of water heater (15 mm. dia).

Each 154 19 173.00

3-1-10 Supplying & erecting 15 mm brass non return valve for inlet pipe of storage water heater.

Each 293 19 312.00

3-1-11 Supplying & erecting dead weight pressure releasing valve for storage water heater with necessary materials.

Each 443 19 462.00

3-1-12 Supplying & erecting vacuum relief valve for storage water heater with necessary materials.

Each 115 19 134.00

3-1-13 Providing fibber reinforced PVC flexible pipe upto 1m length with brass locking nuts and washers and clips at both ends suitable for hot water complete erected in an approved manner.

Each 109 16.89 126.00

3-1-14 Erecting departmentally supplied water heater of 25 ltr capacity with wall fasteners, inlet & outlet pipes, NRV, etc. and marking Sr No. and date of erection.

Each 87 149.91 237.00

3-1-15 Erecting departmentally supplied water heater of 35/ 50 ltr capacity with wall fasteners, inlet & outlet pipes, NRV, etc. and marking Sr No. and date of erection.

Each 100 179.47 279.00

3-1-16 Supplying and erecting ISI mark / M.C.of A.A. heating element 2 / 3 kW suitable for water heater/ midget of any make any capacity.

Each 342 35.89 378.00

3-1-17 Supplying and erecting ISI mark / M.C.of A.A.thermostat suitable for water heater / midget of any make, any capacity.

Each 189 29.56 219.00

3.2 Air Conditioners (AC)

3-2-1

Supplying and erecting window model mounted type room Air - conditioner 2 star 230/250V 50 cycles single phase A.C.supply 1 TR capacity complete at position as per specification No. AP-AC/WAC

Each 233334 1560.32 234894.00

3-2-2

Supplying and erecting window model mounted type room Air - conditioner 3 star 230/250 V 50 cycles single phase A.C.supply 1.5 TR capacity complete at position as per specification No. AP-AC/WAC

Each 30399 1767.24 32166.00

3-2-3

Supplying and erecting window model mounted type room Air- Conditioner 2 star 230/250 V 50 cycles single phase A.C.supply 2 TR capacity complete at position as per specification No. AP-AC/WAC

Each 31777 1767.24 33544.00

3-2-4

Providing modifications to the existing window for erection of window room air conditioner in position with use of teakwood, grill, aluminum channel, glass as per requirement and filling the gaps to maintain air tightness.

Each 504 307.21 811.00

3-2-5

Supplying and erecting split type room Airconditioning unit 3 TR capacity 250V, 50 cycles, A.C. supply having 2 Nos. of air handling units hi-wall mounting type complete at position as per specification No. AP- AC/SAC

Each 59808 6738.53 66547.00

3-2-6

Supplying and erecting split type room Airconditioning unit 2 TR star capacity 250V, 50 cycles, A.C. supply having 2 Nos. of air handling units hi-wall mounting type complete at position as per specification no. AP-AC/SAC

Each 47217 4641.91 51859.00

3-2-7

Supplying and erecting split type room Airconditioning unit 2 TR 3 star capacity 250V, 50 cycles, A.C. supply having 1 No of air handling unit hi-wall mounting type complete at position as per specification no. AP AC/SAC

Each 40272 4583.85 44856.00

3-2-8

Supplying and erecting split type room Airconditioning unit 1.5 TR 5 star capacity 250V, 50 cycles, A.C. supply having 1 No of air handling unit hiwall / floor mounting type complete at position as per specification no. AP-AC/SAC

Each 33463 3369.79 36833.00

3-2-9

Supplying and erecting split type room Airconditioning unit 1 TR star capacity 250V, 50 cycles, A.C. supply having 1 No of air handling unit hi-wall / floor mounting type complete at position as per specification no. AP-AC/SAC

Each 28357 3120.65 31478.00

Page 23: Electrical CSR 12-13

3-2-10

Providing and pesting superior quality Sun control film on glass to acieve better cooling effect having 1.5 / 2 mil thickness, ultra violet transmittance less than 2% and solar heat rejection 78% in approved manner.

Sqm. 579 43.28 622.00

3-2-11

Supplying and erecting split type room Airconditioning unit 2.5 TR capacity 440V, 50 cycles, A.C. supply having 1 No of air handling unit (Mega spilt) Hi-wall mounting type complete at position as per specification No. AP-AC/SAC

Each 61609 6738.53 68348.00

3-2-12

Supplying and erecting split type room Airconditioning unit 3TR capacity 440 V, 50 cycles, A.C. supply having 1 No of air handling unit (Mega spilt) mounting type complete at position as per specification No. AP-AC/SAC

Each 71338 6738.53 78077.00

3-2-13

Supplying and erecting split type room Airconditioning unit 3 TR capacity 250V, 50 cycles, A.C. supply having 2 No of air handling unit (Multi spilt) hi-wall mounting type complete at position as per specification No. AP-AC/SAC

Each 66149 6738.53 72888.00

3-2-14 Supplying & erecting copper pipe suitable for refrigeration system having 22 guage thickness and inner dia / size 12 mm complete.

Mtr. 180 15.84 196.00

3-2-15 Supplying & erecting copper pipe suitable for refrigeration system having 22 guage thickness and inner dia / size 16 mm complete.

Mtr. 241 15.84 257.00

Notes:- For item no 3-2-14 to 3-2-15, rates for nitrite rubber insulation with necessary material on refrigerant piping, increase overall rate by 100%

3-2-16 Supplying & erecting copper pipe suitable for refrigeration system having 22 gauge thickness and inner dia / size 22 mm complete.

Mtr. 433 15.84 449.00

3-2-17 Supplying & erecting copper pipe suitable for refrigeration system having 22 guage thickness and inner dia / size 32 mm complete.

Mtr. 642 15.84 658.00

3-2-18 Supplying & erecting copper pipe suitable for refrigeration system having 22 guage thickness and inner dia / size 35 mm complete.

Mtr. 802 15.84 818.00

3-2-19 Supplying & erecting copper pipe suitable for refrigeration system having 22 guage thickness and inner dia / size 42 mm Complete.

Mtr. 963 15.84 979.00

Notes:- For item no 3-2-16 to 3-2-19, rates for nitrile rubber insulation woth necessary material on refrigent piping, increase overall rate by 50%

3-2-20 Supplying and laying rigid PVC conduit 25 mm dia to drain water with PVC accessories on wall/ceiling as per specification No: WG-MA/CON, para no. 1.1.1

Mtr. 60 8.45 68.00

3-2-21 Supplying and laying rigid PVC conduit 32 mm dia to drain water with PVC accessories on wall/ceiling as per specification No: WG-MA/CON, para no. 1.1.1

Mtr. 97 8.45 105.00

3-2-22 Supplying and laying rigid PVC conduit 50 mm dia to drain water with PVC accessories on wall/ceiling as per specification No: WG-MA/CON, para no. 1.1.1

Mtr. 134 13.72 148.00

Notes:- 1) In future if AC units having star rating more than prescribed in the above items are if available in the market, same shall be preferbly implemented. 2) As per BEE guidelines Appliances shall be used of star rating 3) The above rates for split AC are inclusive of refrigerant piping upto 6 meter length

3.3 Water coolers & Refrigerators (WC)

3-3-1

Supplying refrigerator domestic type approved make 165 to 185 liters storage capacity, suitable for operation on 230/250 Volts 50 cycles complete with automatic temperature control conforming to IS specifications No. 1476/79 with one year guarantee for sealed unit in refrigeration system and marking Sr. No. and date of erection.

Each 11483 0 11483.00

3-3-2

Supplying refrigerator domestic type approved make 285 to 310 liters storage capacity, suitable for operation on 230/250 V 50 cycles complete with automatic temperature control conforming to IS specifications No. 1476/79 with one year guarantee for sealed unit in refrigeration system and marking Sr. No. and date of erection.

Each 21004 0 21004.00

3-3-3

Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50 cycles nominal cooling capacity of 40 liters per hour and storage capacity 80 liters. As per specification No. AP-WCR/WC

Each 40714 388.5 41103.00

3-3-4

Supplying, erecting, testing and commissioning self contained water cooler 230/250 V 50 cycles nominal cooling capacity of 60 liters per hour and storage capacity 120 liters as per specification no. AP- WCR/WC

Each 54285 388.5 54674.00

3-3-5

Supplying, erecting, testing and commissioning self contained water cooler 230/250 Volts 50 cycles nominal cooling capacity of 150 liters per hour and storage capacity 150 liters as per specification No. AP- WCR/WC

Each 64907 388.5 65296.00

3-3-6 new Supplying and erecting, testing and commissioning Solar cum Natural water cooler suitable for hot and dry weather nominal coolling capaicty of 20 litres along with solar panel, fan for cooling, copper storage tank and copper coils with water spraying arrangement as per specifications no. AP-WCR/solar WC

Each 63900 1103 65003.00

Page 24: Electrical CSR 12-13

3-3-7 new Supplying and erecting, testing and commissioning Solar cum Natural water cooler suitable for hot and dry weather nominal coolling capaicty of 50 litres along with solar panel, fan for cooling, copper storage tank and copper coils with water spraying arrangement as per specifications no. AP-WCR/solar WC

Each 77600 1103 78703.00

Note :- Appliances such as refrigerator,Water Coolers should be used of star rating 3 and above as per B.E.E.

3.4 Air Coolers (ACR)

3-4-1 Supplying evaporative air cooler (desert cooler) 230/250 Volts, 50 cycles, normal cooling capacity of 50 cu.m per minute complete as per specification No. AP-WCR/DAC

Each 5106 0 5106.00

3-4-2 Supplying evaporative air cooler (desert cooler) 230/250 Volts, 50 cycles,normal cooling capacity of 65 cu.mtr. per minute complete as per specification No. AP-WCR/DAC

Each 6354 0 6354.00

3-4-3 Supplying evaporative air cooler (desert cooler) 230/250 Volts, 50 cycles, normal cooling capacity of 85 cu.m per minute as per specification No. AP- WCR/DAC

Each 7716 0 7716.00

3.5 Water Purifiers (WPF)

3-5-1

Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water 5 Ltr/min with activated carbon filter and softener operating on 230 V single phase A.C. supply.

Each 8624 104.51 8729.00

3-5-2

Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water 1 Ltr/min with activated carbon filter and softener operating on 230 V single phase A.C. supply.

Each 8386 104.51 8491.00

3-5-3

Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8 W capacity choke made of copper wire and two indicator lamps with output of purified water 3 Ltr/min with activated carbon filter and softener operating on 230 V single phase A.C. supply.

Each ��7538 104.5143 7642.51

3.6(A) Inverter (INV)

3-6-1

Supplying, installing, testing & commissioning of 600 VA Digital pure sine wave inverter based on IGBT technology single phase 230V,50 Hz complete with 1 hr tubular battery backup as per specification no. AP- INV

Each 7623 892.07 8515.00

3-6-2

Supplying, installing, testing & commissioning of 800 VA Digital pure sine wave inverter based on IGBT technology single phase 230V,50 Hz complete with 1 hr tubular battery backup as per specification no. AP-INV

Each 9845 892.07 10737.00

3-6-3

Supplying, installing, testing & commissioning of 1400 VA Digital pure sine wave inverter based on IGBT technology single phase 230V, 50 Hz complete with 1 hr tubular battery backup as per specification no. AP- INV

Each 12749 1248.89 13998.00

3-6-4

Supplying, installing, testing & commissioning of 2500 VA Digital pure sine wave inverter based on IGBT technology single phase 230V,50 Hz complete with 1 hr tubular battery backup as per specification no. AP- INV

Each 19250 2079.73 21330.00

3.6(B)Inverter for Lifts

3-6-5

Supplying, installing, testing & commissioning of Digital pure sine wave inverter for lift (3ph to 3 ph) having capacity 4 kVA with features a) Backup surge current delievery greater than 350% b) balanced type with micro controller based high frequency IGBT technology,with higher protection facility, ultra isolation with inbuilt forced aircooling and high responce in less time complete as per specification no. AP- LIFT-INV ( Without Battery)

Each 65793 2207.47 68000.00

3-6-6

Supplying, installing, testing & commissioning of pure sine wave inverter for lift (3ph to 3 ph) having capacity 5 kVA with features a) Backup surge current delievery greater than 350% b) balanced type with micro controller based high frequency IGBT technology,with higher protection facility, ultra isolation with inbuilt forced aircooling and high responce in less time complete as per specification no. AP- LIFT-INV ( Without Battery)

Each 71303 2207.47 73510.00

3-6-7

Supplying, installing, testing & commissioning of pure sine wave inverter for lift (3ph to 3 ph) having capacity 6 kVA with features a) Backup surge current delievery greater than 350% b) balanced type with micro controller based high frequency IGBT technology,with higher protection facility, ultra isolation with inbuilt forced aircooling and high responce in less time complete as per specification no. AP- LIFT-INV ( Without Battery)

Each 75841 2207.47 78048.00

Page 25: Electrical CSR 12-13

3-6-8

Supplying, installing, testing & commissioning of pure sine wave inverter for lift (3ph to 3 ph) having capacity 7.5 / 8 kVA with features a) Backup surge current delievery greater than 350% b) balanced type with micro controller based high frequency IGBT technology,with higher protection facility, ultra isolation with inbuilt forced aircooling and high responce in less time complete as per specification no. AP- LIFT-INV ( Without Battery)

Each 90425 2207.47 92632.00

3-6-9

Supplying, installing, testing & commissioning of pure sine wave inverter for lift (3ph to 3 ph) having capacity10 kVA with features a) Backup surge current delievery greater than 350% b) balanced type with micro controller based high frequency IGBT technology,with higher protection facility, ultra isolation with inbuilt forced aircooling and high responce in less time complete as per specification no. AP- LIFT-INV ( Without Battery)

Each 104362 2207.47 106569.00

3-6-10

Supplying, installing, testing & commissioning of pure sine wave inverter for lift (3ph to 3 ph) having capacity 12/12.5 kVAwith features a) Backup surge current delievery greater than 350% b) balanced type with micro controller based high frequency IGBT technology,with higher protection facility, ultra isolation with inbuilt forced aircooling and high responce in less time complete as per specification no. AP- LIFT-INV ( Without Battery)

Each 117650 2207.47 119857.00

3-6-11

Supplying, installing, testing & commissioning of pure sine wave inverter for lift (3ph to 3 ph) having capacity 15 kVA with features a) Backup surge current delievery greater than 350% b) balanced type with micro controller based high frequency IGBT technology,with higher protection facility, ultra isolation with inbuilt forced aircooling and high responce in less time complete as per specification no. AP- LIFT-INV ( Without Battery)

Each 145523 2697.31 148220.00

3-6-12

Supplying, installing, testing & commissioning of pure sine wave inverter for lift (3ph to 3 ph) having capacity 18kVA with features a) Backup surge current delievery greater than 350% b) balanced type with micro controller based high frequency IGBT technology,with higher protection facility, ultra isolation with inbuilt forced aircooling and high responce in less time complete as per specification no. AP- LIFT-INV ( Without Battery)

Each 154922 2697.31 157619.00

3-6-13

Supplying, installing, testing & commissioning of pure sine wave inverter for lift (3ph to 3 ph) having capacity 20kVA with features a) Backup surge current delievery greater than 350% b) balanced type with micro controller based high frequency IGBT technology,with higher protection facility, ultra isolation with inbuilt forced aircooling and high responce in less time complete as per specification no. AP- LIFT-INV ( Without Battery)

Each 165294 2697.31 167991.00

3-6-14

Supplying, installing, testing & commissioning of pure sine wave inverter for lift (3ph to 3 ph) having capacity 25kVA with features a) Backup surge current delievery greater than 350% b) balanced type with micro controller based high frequency IGBT technology,with higher protection facility, ultra isolation with inbuilt forced aircooling and high responce in less time complete as per specification no. AP- LIFT-INV ( Without Battery)

Each 186685 3210.38 189895.00

3-6-15

Supplying, installing, testing & commissioning of pure sine wave inverter for lift (3ph to 3 ph) having capacity 30kVAwith features a) Backup surge current delievery greater than 350% b) balanced type with micro controller based high frequency IGBT technology,with higher protection facility, ultra isolation with inbuilt forced aircooling and high responce in less time complete as per specification no. AP- LIFT-INV ( Without Battery)

Each 234004 3210.38 237214.00

3-6-16

Supplying, installing, testing & commissioning of pure sine wave inverter for lift (3ph to 3 ph) having capacity 35kVA with features a) Backup surge current delievery greater than 350% b) balanced type with micro controller based high frequency IGBT technology,with higher protection facility, ultra isolation with inbuilt forced aircooling and high responce in less time complete as per specification no. AP- LIFT-INV ( Without Battery)

Each 262525 3210.38 265735.00

3.7 On line UPS (UPS)

3-7-1 Supplying & erecting On line UPS pure sine wave of 1 kVA capacity complete with standard features,along with necessary tubular batteries for onr hour battery backup, as per specification No. AP-UPS

Each 22394 0 22394.00

3-7-2

Supplying & erecting On line UPS pure sine wave of 2 kVA capacity complete with standard features,along with necessary tubular batteries for onr hour battery backup, as per specification No. AP-UPS

Each 32641 0 32641.00

3-7-3

Supplying & erecting On line UPS pure sine wave of 3 kVA capacity complete with standard features,along with necessary tubular batteries for onr hour battery backup, as per specification No. AP-UPS

Each 41325 0 41325.00

3-7-4

Supplying & erecting On line UPS pure sine wave of 5 kVA capacity complete with standard features,along with necessary tubular batteries for onr hour battery backup, as per specification No. AP-UPS

Each 92052 0 92052.00

3-7-5

Supplying & erecting On line UPS pure sine wave of 6 kVA capacity complete with standard features,along with necessary tubular batteries for onr hour battery backup, as per specification No. AP-UPS

Each 132868 0 132868

3-7-6

Supplying & erecting On line UPS pure sine wave of 8 kVA capacity complete with standard features,along with necessary tubular batteries for onr hour battery backup, as per specification No. AP-UPS

Each 176462 0 176462

3-7-7

Supplying & erecting On line UPS pure sine wave of 10 kVA capacity complete with standard features,along with necessary tubular batteries for onr hour battery backup, as per specification No. AP-UPS

Each 250750 0 250750

Page 26: Electrical CSR 12-13

3.8 Inverter & UPS Batteries 3-8-1 (New)

Supplying and erecting 12 V/80AH TUBULAR Battery with battery terminal wire, duly charged complete with 30 months warranty complete

Each 6744 60.17 6804.00

3-8-2 Supplying and erecting 12 V/100AH TUBULAR Battery with battery terminal wire, duly charged complete with 30 months warranty complete

Each 9940 68.62 10009.00

3-8-3 Supplying and erecting 12 V/120AH TUBULAR Battery with battery terminal wire, duly charged complete with 30 months warranty complete

Each 15317 68.62 15386.00

3-8-4 Supplying and erecting 12 V/150AH TUBULAR Battery with battery terminal wire, duly charged complete with 30 months warranty complete

Each 19100 83.4 19183.00

3-8-5 Supplying and erecting 12 V/180AH TUBULAR Battery with battery terminal wire, duly charged complete with 30 months warranty complete

Each 16359 89.73 16449.00

3-8-6 Supplying and erecting 12 V/210AH TUBULAR Battery with battery terminal wire, duly charged complete with 30 months warranty complete

Each 19568 89.73 19658.00

3.9 Voltage Stabilizers (VS)

3-9-1

Supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160 to 270 V and output voltage 200 to 250 V rated for 0.5 kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core flexible cord and 3 pin 6/16 A plug top suitable for refrigerator for continuous operation and marking Sr. No. and date of erection.

Each 1563 0 1563.00

3-9-2

Supplying and erecting fully automatic line Voltage stabilizer, buck and boost type for operation on input voltage 160 to 270V and output voltage 200 to 250V rated for, 1 kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core flexible cord and 3 pin 6/16A plug top suitable for Water Cooler below 120 liter cooling capacity, and marking Sr. No. and date of erection.

Each 2605 0 2605.00

3-9-3

Supplying and erecting fully automatic line Voltage stabilizer, buck and boost type for operation on input voltage 160 to 270 V and output voltage 200 to 250 V rated for, 3 kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core flexible cord and 3 pin 6/16 A plug top suitable for Air Conditioner of 1 TR / Water Cooler of 120 liter cooling capacity and above, and marking Sr. No. and date of erection.

Each 3462 0 3462.00

3-9-4

Supplying and erecting fully automatic line Voltage stabilizer, buck and boost type for operation on input voltage 160 to 270 V and output voltage 200 to 250 V rated for, 4 kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core flexible cord and 3 pin 6/16 A plug top suitable for Air Conditioner of 1.5 TR, and marking Sr. No. and date of erection.

Each 6368 0 6368.00

3-9-5

Supplying and erecting fully automatic line Voltage stabilizer, buck and boost type for operation on input voltage 160 to 270 V and output voltage 200 to 250 V rated for, 5 kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core flexible cord and 3 pin 6/16 A plug top suitable for Air Conditioner of 2.0 TR, and marking Sr. No. and date of erection.

Each 7179 0 7179.00

3-9-6

Providing single phase auto/manual line voltage servo motor operated voltage stabilizer conforming to IS 9815-1981 rated for 165 to 250 Volts and output voltage 230 +/<196> 1% Volts of 5 kVA capacity and marking Sr. No. and date of erection as per specification no. AP-VS/SVS

Each 13026 0 13026.00

3-9-7

Providing single phase auto/manual line voltage servo motor operated voltage stabilizer conforming to IS 9815-1981 rated for 165 to 250V and output voltage 230 +/<196> 1% Volts of 3 kVA capacity and marking Sr. No. and date of erection as per specification No. AP-VS/SVS

Each 7816 0 7816.00

3.10 Dismantling

3-10-1 Dismantling the existing electric Geyser or storage type water heater of any size along with plumbing connections and making the site clear.

Each 13 51.73 65.00

3-10-2 Dismantling the existing window type air conditioner of any type and capacity safely without any damages and making the site clear.

Each 0 250.2 250.00

3-10-3 Dismantling the existing split type air conditioner of any type and capacity safely without any damages and making the site clear.

Each 0 623.92 624.00

Note:- The rates for item no 3.10.1 to 3.10.3 are for dismantling and handing over to section office inclusive of transportation upto 25 km, between site and section office.

Chapter 4 : ENERGY SAVING DEVICES (ESD) 4.1 Solar Hot Water System (SHWS)

4-1-1 Supplying & Installing, Testing & Commissioning of Solar water heating system without heat exchanger type of 125 LPD capacity as per specification No. ESD-SHWS

Each 29529 1266.84 30796.00

4-1-2 Supplying & Installing, Testing & Commissioning of Solar water heating system without heat exchanger type of 250 LPD capacity as per specification No. ESD-SHWS

Each 48435 1900.26 50335.00

4-1-3 Supplying & Installing, Testing & Commissioning of Solar water heating system without heat exchanger type of 500 LPD capacity as per specification No. ESD-SHWS

Each 98820 3167.1 101987.00

Page 27: Electrical CSR 12-13

4-1-4 Supplying & Installing, Testing & Commissioning of Solar water heating system without heat exchanger type of 1000 LPD capacity as per specification No. ESD-SHWS

Each 181852 6334.2 188186.00

4-1-5 Deleted 4-1-6 Deleted Note :- 1)If the Solar water heating system is to be provided with heat

exchanger increase overall rates by 15% 2)For all Hostel Bldg, Rest Houses, Circuit Houses, Dormitories and upto 2 Storey Residential quarters, Solar water heating System shall be proposed for new installation and for replacement / renovation instead of Electrical water Heater. 3) For providing SWHS system with glass tube collector deduct overall rate by 20 %

4.2 Pipes for Solar Hot Water System 4-2-1 Supplying and erecting G.I pipe 15 mm dia B class with resin bonded flap

rock wool/glass wool insulation, with necessary material as per specification No. (ESD-HWP/TGP)

Mtr. 347 49.62 397.00

4-2-2 Supplying and erecting G.I pipe 20 mm dia B class with resin bonded flap rock wool/glass wool insulation, with necessary material as per specification No. (ESD-HWP/TGP)

Mtr. 469 49.62 519.00

4-2-3 Supplying and erecting G.I pipe 25 mm dia B class with resin bonded flap rock wool/glass wool insulation, with necessary material as per specification No. (ESD-HWP/TGP)

Mtr. 524 100.29 624.00

4-2-4 Supplying and erecting G.I pipe 32 mm dia B class with resin bonded flap rock wool/glass wool insulation, with necessary material as per specification No. (ESD-HWP/TGP)

Mtr. 674 100.29 774.00

4-2-5 Supplying and erecting G.I pipe 40 mm dia B class with resin bonded flap rock wool/glass wool insulation, with necessary material as per specification No. (ESD-HWP/TGP)

Mtr. 809 100.29 909.00

4-2-6 Supplying and erecting G.I pipe 50 mm dia B class with resin bonded flap rock wool/glass wool insulation, with necessary material as per specification no. (ESD-HWP/TGP)

Mtr. 1007 100.29 1107.00

4-2-7 Supplying and erecting 12 mm polyethylene composite pipe duly joined by compression/crimp fitted accessories, with internal as well as external end sealing arrangement as per specification No. (ESD-HWP/PCP)

Mtr. 235 49.62 285.00

4-2-8 Supplying and erecting 16 mm polyethylene composite pipe duly joined by compression/crimp fitted accessories, with internal as well as external end sealing arrangement as per specification No. (ESD-HWP/PCP)

Mtr. 277 49.62 327.00

4-2-9 Supplying and erecting 20 mm polyethylene composite pipe duly joined by compression/crimp fitted accessories, with internal as well as external end sealing arrangement as per specification No. (ESD-HWP/PCP)

Mtr. 277 49.62 327.00

4-2-10 Supplying and erecting 25 mm polyethylene composite pipe duly joined by compression/crimp fitted accessories, with internal as well as external end sealing arrangement as per specification No. (ESD-HWP/PCP)

Mtr. 405 49.62 455.00

4-2-11 Supplying and erecting 32 mm polyethylene composite pipe duly joined by compression/crimp fitted accessories, with internal as well as external end sealing arrangement as per specification no. (ESD-HWP/PCP)

Mtr. 586 49.62 636.00

4-2-12 Supplying and erecting 40 mm polyethylene composite pipe duly joined by compression/crimp fitted accessories, with internal as well as external end sealing arrangement as per specification No. (ESD-HWP/PCP)

Mtr. 749 49.62 799.00

4-2-13 Supplying and erecting Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having 9 mm thickness and inner diameter / sizes 6 mm as per specification no ESD-ENR

Mtr. 53 2.11 55.00

4-2-14 Supplying and erecting Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having 9 mm thickness and inner diameter / sizes 9 mm as per specification no ESD-ENR

Mtr. 59 2.11 61.00

4-2-15 Supplying and erecting Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having 9 mm thickness and inner diameter / sizes 12 mm as per specification no ESD-ENR

Mtr. 75 2.11 77.00

4-2-16 Supplying and erecting Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having 9 mm thickness and inner diameter / sizes 16 mm as per specification no ESD-ENR

Mtr. 80 5.28 85.00

4-2-17 Supplying and erecting Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having 9 mm thickness and inner diameter / sizes 19 mm as per specification no ESD-ENR

Mtr. 96 5.28 101.00

4-2-18 Supplying and erecting Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having 9 mm thickness and inner diameter / sizes 22 mm as per specification no ESD-ENR

Mtr. 107 6.33 113.00

Page 28: Electrical CSR 12-13

4-2-19 Supplying and erecting Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having 9 mm thickness and inner diameter / sizes 28 mm as per specification no ESD-ENR

Mtr. 124 7.39 131.00

4-2-20 Supplying and erecting Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having 9 mm thickness and inner diameter / sizes 32 mm as per specification no ESD-ENR

Mtr. 136 7.39 143.00

4-2-21 Supplying and erecting Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having 9 mm thickness and inner diameter / sizes 42 mm as per specification no ESD-ENR

Mtr. 189 8.45 197.00

Note :- 1) For polyethylene composite pipe additional insulation may be proposed where there is drastic fall in temperature due to atmospheric condition

4.3 Solar Lighting (SOL) 4-3-1 Supplying & erecting duly certified by MNES Solar Street Light Fitting

with 9/11 W CFL, with pole, c c foundtion, 12 V, 75 AH battery Complete as per specification no. ESD-SOL/STL

Each 32123 2210.64 34334.00

4-3-2 Supplying & erecting Solar home Light system with structure as per MNES specification with 1 no of CFL lamp of 9 W / 11W, 12 V, 20Ah battery as per specification No. ESD-SOL/SHL

Each 10338 0 10338.00

4-3-3 Supplying & erecting Solar home Light system with structure as per MNES specification with 2 nos of CFL lamp of 9 W / 11W, 12 V, 40Ah battery as per specification No. ESD-SOL/SHL

Each 17636 0 17636.00

4-3-4 Supplying & erecting Solar home Light system with structure as per MNES specification with 1 no of CFL lamp of 9 W / 11W, 1 No D C fan rating < 20 W, 12 V, 40 Ah battery as per specification no. ESD- SOL/SHL

Each 17818 0 17818.00

4-3-5 Supplying and erecting Solar panel comprising high efficiency mono- crystane / multi cryline Photo Voltaic Cell 20 W Per Single module suitable for 4-5 hrs backup with necessary clamps and module frame as per specification no. ESD-SOL/CELL

Each 9638 157.3 9795.00

4-3-6 Supplying and erecting approved make battery with capacity of 12 V 25 AH with duty cycle 8-10 hrs suitable to charge on PV cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no. ESD-SOL/BAT

Each 8128 157.3 8285.00

4-3-7 Supplying and erecting approved make battery with capacity of 12 V 40 AH with duty cycle 10-12 hrssuitable to charge on PV cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no. ESD-SOL/BAT

Each 8451 157.3 8608.00

4-3-8 Supplying and erecting approved make battery with capacity of 12 V 75 AH with duty cycle 10-12 hrs suitable to charge on PV cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no. ESD-SOL/BAT

Each 13117 157.3 13274.00

4-3-9 Supplying and erecting Solar Power Generator up to 100 WP 230V, 50 Hz for connecting between battery and light fixture as per specification no. ESD- SOL/GEN

Each 3075 40.12 3115.00

Note :- While framing the estimate of solar street light with solar PV panel , battery, converter, the above items should be taken along with provided street light pole bracket and necessary street light fitting

4.4 Energy Devices (Harmonic Filter, APFC Panel) (ESD) 4-4-1 Carrying out Power quality analysis of the exisiting load at point of

supply/or as directed, with use of necessary equipment's and submission of detail analysis report with remedial measures, as per specification no (ESD- ED/PQA)

per feeder

0 4828.77 4829.00

After carrying out detailed Power Quality analysis of existing load and on the basis of analysis Active Harmonic filter is to be provided, in addition to necessary capacitors / APFC with capacitors.

4-4-2 Deleted 4-4-3 Supplying, erecting, testing, and commissioning of Digital Active 60 A

Harmonic filter cum Power conditioner, with Digital Closed Loop Active Filter with Source Current Sensing, 32 bit, Digital Signal processing, High speed IGBTs in power circuit with necessary CTs to be mounted on existing cable/bus and shunted to supply as per specification No. ESD-ED/DAHF

Each 550207 0 550207.00

4-4-4 Supplying and erecting 30 kVAR , 440 V Three phase, 50 cycles, THYRISTER SWITCHED MICRO APFC PASSIVE FILTER PANEL, consisting of (10kx3) steps of APP type capacitor units confirming to IS- 13585 ( Part – I ) 1994 with harmonic filter reactors, suitable for 50 kW load as per specification no ESD-APFC

Each 149226 25072.88 174299.00

Page 29: Electrical CSR 12-13

4-4-5 Supplying and erecting 40 kVAR , 440 V Three phase, 50 cycles, THYRISTER SWITCHED MICRO APFC PASSIVE FILTER PANEL, consisting of (15k x 2 + 10k x1) steps of APP type capacitor units confirming to IS- 13585 ( Part – I ) 1994 with harmonic filter reactors, suitable for 75 kW load as per specification no ESD-APFC

Each 162196 25072.88 187269.00

4-4-6 Supplying and erecting 50 kVAR , 440 V Three phase, 50 cycles, THYRISTER SWITCHED MICRO APFC PASSIVE FILTER PANEL, consisting of (25k + 15k +10k) steps of APP type capacitor units confirming to IS- 13585 ( Part – I ) 1994 with harmonic filter reactors, suitable for 100 kW load as per specification no ESD-APFC

Each 188137 25072.88 213210.00

4-4-7 Supplying and erecting 80/100 kVAR , 440 V Three phase, 50 cycles, THYRISTER SWITCHED MICRO APFC PASSIVE FILTER PANEL, consisting of (25k x2 +15k x2) steps of APP type capacitor units confirming to IS- 13585 ( Part – I ) 1994 with harmonic filter reactors, suitable for 150 kW load as per specification no ESD-APFC

Each 233533 25072.88 258606.00

4-4-8 Supplying and erecting 125/150 kVAR , 440 V Three phase, 50 cycles, THYRISTER SWITCHED MICRO APFC PASSIVE FILTER PANEL, consisting of (25k x4 +15k x1 +10kx1) steps of APP type capacitor units confirming to IS- 13585 ( Part – I ) 1994 with harmonic filter reactors, suitable for 200 kW load as per specification no ESD-APFC

Each 317840 25072.88 342913.00

4-4-9 (New)

Supplying and erecting 200 kVAR , 440 V Three phase, 50 cycles, THYRISTER SWITCHED MICRO APFC PASSIVE FILTER PANEL, consisting of (25k x4 +15k x1 +10kx1) steps of APP type capacitor units confirming to IS- 13585 ( Part – I ) 1994 with harmonic filter reactors, suitable for 200 kW load as per specification no ESD-APFC

Each 494867 25072.88 519940.00

4-4-10 (New)

Supplying and erecting 250 kVAR , 440 V Three phase, 50 cycles, THYRISTER SWITCHED MICRO APFC PASSIVE FILTER PANEL, consisting of (25k x4 +15k x1 +10kx1) steps of APP type capacitor units confirming to IS- 13585 ( Part – I ) 1994 with harmonic filter reactors, suitable for 200 kW load as per specification no ESD-APFC

Each 576215 25072.88 601288.00

4-4-11 (New)

Supplying, erecting, testing, and commissioning of Digital Active 100 A Harmonic filter cum Power conditioner, with Digital Closed Loop Active Filter with Source Current Sensing, 32 bit, Digital Signal processing, High speed IGBTs in power circuit with necessary CTs to be mounted on existing cable/bus and shunted to supply as per specification No. ESD-ED/DAHF

Each 926663 1544.49 928207.00

4-4-12 (New)

Supplying, erecting, testing, and commissioning of Digital Active 150 A Harmonic filter cum Power conditioner, with Digital Closed Loop Active Filter with Source Current Sensing, 32 bit, Digital Signal processing, High speed IGBTs in power circuit with necessary CTs to be mounted on existing cable/bus and shunted to supply as per specification No. ESD-ED/DAHF

Each 1042496 1544.49 1044040.00

Note :- After doing quality analysis , if it is observed that filters are required to compensate only reactive power and not harmonics then the above items shall be used with proper designing.

4.5 Miscellaneous 4-5-1 Supplying and erecting protector and Energy saver equipment

working on 180-260 V cut off control with suitable MCB and built up timer + 3 minutes and automatic operation for 1 minute to 24 hours adjustable and all installed in M.S. powder coated box.

Each 5024 29.56 5054.00

4-5-2 Supplying and erecting an energy saver for air conditioner working on 180- 260 V cut off controlled voltage with suitable MCB for over current and short circuit protection, at least 3 minutes initial time delay with automatic operation from 1 minute to 24 hours settings . The unit is digitally controlled system with spike protector to enhance the life of the compressor and the unit is installed in MS powder coated box.

Each 4020 29.56 4050.00

4-5-3 Supplying and erecting Quartz Electronic time switch having 24 hour dial to work on 250V 50 cycle A.C. having built in rechargeable Nickel Cadmium batteries to run the time switch on failure of supply having switch contact rating upto 16A to use independently or in conjunction with contactor.

Each 2734 49.62 2784.00

4-5-4 Supplying and erecting two pole power contactor 250V 12A for time switch complete erected on wooden block/provided box, with necessary materials.

Each 909 55.95 965.00

4-5-5 Supplying and erecting two pole power contactor 250V 32A for time switch complete erected on wooden block/provided box, with necessary materials.

Each 3196 55.95 3252.00

4-5-6 Supplying and erecting 4 pole power contactor 440V 16A for time switch complete erected on wooden block/provided box, with necessary materials.

Each 1021 55.95 1077.00

4-5-7 Supplying and erecting 4 pole power contactor 440V 40A for time switch complete erected on wooden block/provided box, with necessary materials.

Each 4671 55.95 4727.00

Page 30: Electrical CSR 12-13

4-5-8 Supplying and erecting Programmable Digital Almanac Timer Micro- controller based with real time clock to operate on derived switching“ON” & switching “OFF” street light as per daily sunset and sunrise respectively automatically having 4 digit LED continuous time display, relay output 230V / 10A with 10 Hrs battery backup and manual over drive facility capable to drive different capacity contactors timer erected in MS box in an approved manner.

Each 8102 55.95 8158.00

4-5-9 Supplying and erecting Mega Intelligent Energy Saver suitable up to 5 TR Window / Split Type Air Conditioning Unit working on voltage of 230V single phase solid state microprocessor based intelligent control wall mounting connected to indoor unit as per specification no ESD- AC

Each 6068 353.66 6422.00

4-5-10 Supplying and erecting Mega Intelligent Energy Saver suitable fo package Type Air Conditioning Unit working on voltage of 230V single phase solid state microprocessor based intelligent control wall mounting connected to indoor unit ESD- AC

Per Ton

6742 409.61 7152.00

4.6 LED Fittings (ESD-LED) 4-6-1 Supplying & Erecting approved make recess/surface type LED fittings of

size 600 mm x 600 mm,12 W, with minimum 200 lux level at working plane 2m below & angle of dispersion of 90 degree, with P.F. > 0.95 with frosted glass (Equivalent to 1 x 18 W CFL ) as per specification no ESD- LED /IDF

Each 5249 82.34 5331.00

4-6-2 Supplying & Erecting approved make recess/surface type LED fittings of size 600 mm x 600 mm,30 W, with minimum 300 lux level at working plane & angle of dispersion of 90 degree, with P.F. > 0.95 with frosted glass (Equivalent to 2 x 18 W CFL ) as per specification no ESD- LED /IDF

Each 14599 82.34 14681.00

4-6-3 Supplying & Erecting approved make recess/surface type LED fittings of size 1200 mm x 150 mm,15 W, with minimum 200 lux level at working plane 2m below with P.F. > 0.95 with frosted glass (Equivalent to 1 x 40 W FTL ) as per specification no ESD- LED /IDF

Each 8784 82.34 8866.00

4-6-4 Supplying & Erecting approved make recess/surface type LED fittings of size 1200mm x 150mm,30 W,with minimum 300 lux level at working plane 2m belowwith P.F. > 0.95 with frosted glass (Equivalent to 2 x 40 W FTL ) as per specification no ESD- LED /IDF

Each 14599 82.34 14681.00

4-6-5 Supplying & Erecting approved make recess/surface LED down lighter fitting of 150 mm dia round / square shape, 8W, with minimum 100 luxlevel at working plane with P.F. > 0.95 with frosted glass (Equivalent to 1 x 15 W CFL ) as per specification no ESD- LED /IDF

Each 4429 82.34 4511.00

4-6-6 Supplying & Erecting approved make recess/surface LED down lighter fitting of 150 mm dia round / square shape, 15 W, with minimum 150 lux level at working plane with P.F. > 0.95 with frosted glass (Equivalent to 2 x 15 W CFL ) as per specification no ESD- LED /IDF

Each 4757 82.34 4839.00

4-6-7 Supplying & Erecting approved make recess/surface LED down lighter fitting of 75 mm dia round / square shape, 5 W with minimum 50 lux level at working plane with P.F. > 0.95 with lens (Equivalent to 1 x 11 W CFL ) as per specification no ESD- LED /IDF

Each 2461 82.34 2543.00

4-6-8 Supplying & Erecting approved make recess/surface LED down lighter fitting of 125 mm dia round / square shape, 11 W,with minimum 150 lux level at working plane with P.F. > 0.95 with lens (Equivalent to 1 x 18 W CFL ) as per specification no ESD- LED /IDF

Each 4429 82.34 4511.00

4-6-9 Supplying & Erecting LED bulkhead Fitting of appropriate size with 8 W with minimum 50-70 lux level at ground level with p.f. > 0.95 with frosted glass (Equivalent to 1 x 18 watt CFL ) as per specification no ESD-LED /BHF

Each 3691 82.34 3773.00

4-6-10 Supplying & Erecting Spot light LED fitting of appropriate size with 6 W with minimum 75 lux level at ground level with p.f. > 0.95 with transparent lens (Equivalent to 1 x 35 W Halogen bulb ) as per specification no ESD- LED / HAL

Each 2095 82.34 2177.00

4-6-11 Supplying & Erecting Spot light LED fitting of appropriate size with 3 W with minimum 50 lux level at ground level with p.f. > 0.95 with transparent lens (Equivalent to 1 x 50 W Halogen bulb ) as per specification no ESD-LED /HAL

Each 3120 82.34 3202.00

4-6-12 Supplying & Erecting LED street light suitable with 12 W with minimum 6- 8 lux level at ground level with p.f. > 0.95 with transparent lens (Equivalent to 2 x 11 W CFL ) as per specification no ESD-LED /ODF

Each 5988 250.2 6238.00

4-6-13 Supplying & Erecting LED street light suitable with 15 W with minimum 10- 12 lux level at ground level with p.f. > 0.95 with transparent lens (Equivalent to 2 x 18 W CFL ) as per specification no ESD-LED /ODF

Each 8530 250.2 8780.00

4-6-14 Supplying & Erecting LED street light suitable with 30 W with minimum 18- 20 lux level at ground level with p.f. > 0.95 with transparent lens (Equivalent to 2 x 36W CFL ) as per specification no ESD-LED /ODF

Each 10663 250.2 10913.00

4-6-15 Supplying & Erecting LED Flood Light fitting of appropriate size with 48 / 40 S W lux level at ground min 50 lux ,with p.f. > 0.95 with transparent lens (Equivelant to 75 W fitting) as per specification no ESD-LED /ODF

Each 20496 250.2 20746.00

4-6-16 Supplying & Erecting LED Flood Light fitting of appropriate size with 56/ 48 W lux level at ground min 50 lux ,with p.f. > 0.95 with transparent lens (Equivelant to 150 W fitting) as per specification no ESD-LED /ODF

Each 22146 250.2 22396.00

Page 31: Electrical CSR 12-13

4-6-17 Supplying & Erecting LED Flood Light fitting of appropriate size with 80 / 70 W lux level at ground min 50 lux ,with p.f. > 0.95 with transparent lens (Equivelant to 250 W fitting) as per specification no ESD-LED /ODF

Each 31168 250.2 31418.00

4-6-18 Supplying & Erecting LED Flood Light fitting of appropriate size with 115 / 100 W lux level at ground min 50 lux ,with p.f. > 0.95 with transparent lens (Equivelant to 400 Watts fitting) as per specification no ESD-LED /ODF

Each 34449 250.2 34699.00

4-6-19 Supplying & Erecting LED solar street light of appropriate size suitable for 50 lux level at ground level with mounting height of fitting 5-7 m height from ground with IP 65 ingress protection with 12/14 W , lux level at ground min 50 lux ,with p.f. > 0.95 with transparent lens as per specification no ESD- LED /ODF

Each 20647 250.2 20897.00

4-6-20 Supplying & Erecting LED solar street light of appropriate size suitable for 50 lux level at ground level with mounting height of fitting 5-7 m height from ground with IP 65 ingress protection with 24/26 W , lux level at ground min 50 lux ,with p.f. > 0.95 with transparent lens as per specification no ESD- LED /ODF

Each 18146 250.2 18396.00

4-6-21 Supplying & Erecting LED solar street light of appropriate size suitable for 50 lux level at ground level with mounting height of fitting 5-7 m height from ground with IP 65 ingress protection with 37 W , lux level at ground min 50 lux ,with p.f. > 0.95 with transparent lens as per specification no ESD- LED /ODF

Each 21747 250.2 21997.00

4-6-22 Supplying & Erecting LED solar street light of appropriate size suitable for 50 lux level at ground level with mounting height of fitting 5-7 m height from ground with IP 65 ingress protection with 74 W , lux level at ground min 50 lux ,with p.f. > 0.95 with transparent lens as per specification no ESD-LED /ODF

Each 40952 250.2 41202.00

4-6-23 Supplying & Erecting foot light / pathway rechargeable 5 W LED fitting with 2 hrs backup , NI-CD/NI-MH rechargeable battery up to 24 hrs aluminium body with SS cover (IP 65) as per specification no ESD-LED /ODF

Each 4429 82.34 4511.00

4-6-24 (New)

Supplying & Erecting approved make recess/surface type LED fittings with 2 hrs battery backup of size 1200mm x 150mm,15 W,with minimum 0 200 lux level with 120 dispertion angle with brush steel finish housing at working plane 2m below with P.F. > 0.95 with frosted glass (Equivalent to 40 -50 FTG ) as per specification no ESD- LED /IDF

Each 7526 82.34 7608.00

4-6-25 (New)

Supplying & erecting Round LED flexible rope indoor light- 2 wire with 1.5 to 2 W per meter suitable for 240 V AC supply in any colour with 3400 degree kelvins to 7000 degree k with necessary material, wiring & connections etc.

Mtr. 391 5.28 396.00

4-6-26 (New)

Supplying & erecting Flexible strip LED rope indoor light- 2 wire with 5 W per meter suitable for 240 V AC supply in any colour with 3400 degree kelvins to 7000 degree k with necessary material, wiring & connections etc.

Mtr. 811 5.28 816.00

4-6-27 (New)

Supplying & erecting LED neon flex rope indoor light- 2 wire with 3 to 4 W per meter suitable for 240 V AC supply in any colour with 3400 degree kelvins to 7000 degree k with necessary material, wiring & connections etc.

Mtr. 1146 5.28 1151.00

4-6-28 (New)

Supplying and erecting power cord ( Adaptor ) for Round LED / strip LED / neon flex LED rope light

Each 417 5.28 422.00

Chapter : 5 SWITCHGEARS (SW)

5.1 LT - IC/MC Switchgears, ATS (SWR) 5-1-1 Supplying and erecting Bakelite D.P. switch surface type/ flush type 32A

250V with indicator lamp as per specification No. SW-SWR/BDPEach 134 47.51 182.00

5-1-2 Supplying and erecting double pole metal /iron clad switch with fuse and neutral link 250V 16A on iron frame/board as per specification No. SW- SWR/MDP

Each 414 47.51 462.00

5-1-3 Supplying and erecting double pole metal /iron clad switch with H.C. type fuse and neutral link 250V, 32A on iron frame/board as per specification No. SW-SWR/MDP

Each 781 47.51 829.00

5-1-4 Supplying and erecting double pole metal /iron clad switch with fuse 63A 250V on iron frame/board as per specification No. SW-SWR/MDP

Each 2262 47.51 2310.00

5-1-5 Supplying and erecting Triple pole metal/ iron clad switch & H.C. type fuse 415/ 500V 16A on iron frame/board as per specification No. SW- SWR/MTP

Each 800 47.51 848.00

5-1-6 Supplying and erecting Triple pole metal/ iron clad switch & fuse 415/ 500V 32A on iron frame/board as per specification No. SW-SWR/MTP

Each 1095 47.51 1143.00

5-1-7 Supplying and erecting Triple pole metal/ iron clad switch and fuse 415/500V 63A on angle iron frame as per specification No. SW-SWR/MTP

Each 2517 63.34 2580.00

5-1-8 Supplying and erecting Triple pole metal/ iron clad switch and fuse 415/ 500V 100A on angle iron frame as per specification No. SW-SWR/MTP

Each 4657 125.63 4783.00

Page 32: Electrical CSR 12-13

5-1-9 Supplying and erecting Triple pole metal/ iron clad re- wireable fuse switch 415/ 500V 200A on angle iron frame as per specification No. SW- SWR/MTP

Each 6173 125.63 6299.00

5-1-10 Supplying and erecting Triple pole metal clad HRC fuse switch 415/ 500V 300A with ISI marked HRC fuses, on angle iron frame as per specification No.SW-SWR/TPHRC

Each 13360 157.3 13517.00

5-1-11 Supplying and erecting Triple pole iron clad HC type rewireable fuse and switch 415/ 500V 16A with neutral link on angle iron frame as per specification No.SW-SWR/MTP

Each 1070 47.51 1118.00

5-1-12 Supplying and erecting Triple pole iron clad H.C. type rewireable fuse and switch 415/ 500V 32A with neutral link on angle iron frame as per specification No. SW-SWR/MTP

Each 1511 47.51 1559.00

5-1-13 Supplying and erecting Triple pole iron clad H.C. type rewireable fuse and switch 415/ 500V 63A with neutral link on angle iron frame as per specification No. SW-SWR/MTP

Each 3376 63.34 3439.00

5-1-14 Supplying and erecting Triple pole metal/ iron clad switch and fuse 415/ 500V 100A with neutral link on angle iron frame as per specification No. SW-SWR/MTP

Each 4754 124.57 4879.00

5-1-15 Supplying and erecting Triple pole metal clad/ iron clad rewireable fuse 415/ 500V 200A with neutral link on angle iron frame as per specification No. SW-SWR/MTP

Each 8696 157.3 8853.00

5-1-16 Supplying and erecting Triple pole metal/ iron clad HRC fuse switch 415/ 500V 63A with neutral link with ISI marked HRC fuses on angle iron frame as per specification No.SW-SWR/TPHRC

Each 5220 78.12 5298.00

5-1-17 Supplying and erecting Triple pole metal/ iron clad HRC fuse switch 415/ 500 V.100 A. with neutral link with ISI marked HRC fuses on angle iron frame as per specification no. SW-SWR/TPHRC

Each 7317 118.24 7435.00

5-1-18 Supplying and erecting Triple pole metal/ iron clad HRC fuse switch 415/ 500V 200A with neutral link with ISI marked HRC fuses on angle iron frame as per specification No. SW-SWR/TPHRC

Each 11648 173.13 11821.00

5-1-19 Supplying and erecting Triple pole metal / iron clad HRC fuse switch 415/ 500V 300A with neutral link with ISI marked HRC fuses, on angle iron frame as per specification No. SW-SWR/TPHRC

Each 13671 173.13 13844.00

5-1-20 Supplying and erecting Triple pole metal clad HRC fuse switch 415/ 500V 400A with neutral link with ISI marked HRC fuses, on angle iron frame as per specification No. SW-SWR/TPHRC

Each 20413 251.26 20664.00

5-1-21 Supplying and erecting Triple pole metal clad HRC fuse switch 415/ 500V 500A with neutral link with ISI marked HRC fuses, on angle iron frame as per specification No. SW-SWR/TPHRC

Each 22720 251.26 22971.00

5-1-22 Supplying and erecting Triple pole metal clad HRC fuse switch 415/ 500V 630A with neutral link with ISI marked HRC fuses, on angle iron frame. As per specification No. SW-SWR/TPHRC

Each 24425 251.26 24676.00

5-1-23 Supplying and erecting Triple pole metal clad HRC fuse switch 415/ 500V 800A with neutral link with ISI marked HRC fuses, on angle iron frame as per specification No. SW-SWR/TPHRC

Each 36158 251.26 36409.00

5-1-24 Supplying & erecting Four pole Iron clad/metal clad ON LOAD change over switch 16A, 415/500V erected on angle iron frame approved make.

Each 1487 78.12 1565.00

5-1-25 Supplying & erecting Four pole Iron clad/metal clad ON LOAD change over switch 32A, 415/500V erected on angle iron frame approved make.

Each 1773 78.12 1851.00

5-1-26 Supplying & erecting Four pole Iron clad/metal clad ON LOAD change over switch 63A, 415/500V erected on angle iron frame approved make.

Each 4314 78.12 4392.00

5-1-27 Supplying & erecting on load four pole Iron clad/metal clad ON LOAD change over switch 100A, 415/ 500V erected on angle iron frame approved make.

Each 8320 118.24 8438.00

5-1-28 Supplying & erecting on load Four pole Iron clad/metal clad ON LOAD change over switch 200A, 415/500V erected on angle iron frame approved make.

Each 12234 173.13 12407.00

5-1-29 Supplying & erecting on load Four pole Iron clad/metal clad ON LOAD change over switch 300A, 415/500V erected on angle iron frame approved make.

Each 16351 235.42 16586.00

5-1-30 Supplying & erecting on load Four pole Iron clad/metal clad ON LOAD change over switch 400A, 415/500V erected on angle iron frame approved make.

Each 24636 251.26 24887.00

5-1-31 Supplying and erecting two pole iron clad/ metal clad ON LOAD change over switch 16A 250V erected on angle iron frame approved make and duly connected with suitable wire leads.

Each 741 63.34 804.00

5-1-32 Supplying and erecting two pole iron clad/ metal clad ON LOAD change over switch 32A 250V erected on angle iron frame approved make and duly connected with suitable wire leads.

Each 994 63.34 1057.00

5-1-33 Supplying and erecting approved make ON LOAD Four Pole Automatic Transfer Switch suitable for 440V, 50 Hz, 100A capacity conforming to IEC: 60947-1 & IEC: 947-6-1/ IS: 13947-1, with Enclosure, automatic/manual inbuilt Time delay, high transfer speed, excellent breaking capacity, superior making capacity, compact & light weight, erected on provided angle iron frame and connected with provided leads.

Each 42720 118.24 42838.00

Page 33: Electrical CSR 12-13

5-1-34 Supplying and erecting approved make ON LOAD Four Pole Automatic Transfer Switch suitable for 440V, 50 Hz, 160A capacity conforming to IEC: 60947-1 & IEC: 947-6-1/ IS: 13947-1, with Enclosure, automatic/manual inbuilt Time delay, high transfer speed, excellent breaking capacity, superior making capacity, compact & light weight, erected on provided angle iron frame and connected with provided leads.

Each 52720 173.13 52893.00

5-1-35 Supplying and erecting approved make ON LOAD Four Pole Automatic Transfer Switch suitable for 440V, 50 Hz, 200A capacity conforming to IEC: 60947-1 & IEC: 947-6-1/ IS: 13947-1, with Enclosure, automatic/manual inbuilt Time delay, high transfer speed, excellent breaking capacity, superior making capacity, compact & light weight, erected on provided angle iron frame and connected with provided leads.

Each 60653 173.13 60826.00

5.2 IC / MC Distribution Boards (DB) 5-2-1 Supplying and erecting metal clad distribution board approved make

250V. 2 way,16A. per way & neutral bar connector complete erected on iron frame/ wooden plank or Board as per specification no. SW- SWR/MDB

Each 351 24.28 375.00

5-2-2 Supplying and erecting metal clad distribution board approved make 250V 3 way, 16A. per way & neutral bar connector complete erected on iron frame/ wooden plank or Board as per specification No. SW- SWR/MDB

Each 449 24.28 473.00

5-2-3 Supplying and erecting metal clad distribution board approved make 250V, 4 way, 16A. per way & neutral bar connector complete erected on iron frame/ wooden plank or Board as per specification No. SW-SWR/MDB

Each 537 24.28 561.00

5-2-4 Supplying and erecting metal clad distribution board approved make 250V. 6 way,16A. per way & neutral bar connector complete erected on iron frame/ wooden plank or Board as per specification no. SW- SWR/MDB

Each 685 24.28 709.00

5-2-5 Supplying and erecting metal clad distribution board approved make 250V. 8 way,16A. per way & neutral bar connector complete erected on iron frame/ wooden plank or Board as per specification no. SW- SWR/MDB

Each 855 24.28 879.00

5-2-6 Supplying and erecting metal clad distribution board approved make 415/500V, 3 way, 16A. per way & neutral bar connector complete erected on iron frame/ wooden plank or Board as per specification No. SW- SWR/MDB

Each 1295 47.51 1343.00

5-2-7 Supplying and erecting metal clad distribution board approved make 415/500V, 4 way, 16A per way & neutral bar connector complete erected on iron frame/ wooden plank or Board as per specification No. SW- SWR/MDB

Each 2286 47.51 2334.00

5-2-8 Supplying and erecting metal clad distribution board approved make 415/500V, 6 way, 16A. per way & neutral bar connector complete erected on iron frame/ wooden plank or Board as per specification No. SW- SWR/MDB

Each 3311 47.51 3359.00

5-2-9 Supplying and erecting metal clad distribution board approved make 415/500 V, 8 way, 16 A. per way & neutral bar connector complete erected on iron frame/ wooden plank or Board as per specification No. SW-SWR/MDB

Each 3836 55.95 3892.00

5-2-10 Supplying and erecting metal clad distribution board approved make 415/500V, 3 way, 32A. per way & neutral bar connector complete erected on iron frame/ wooden plank or Board as per specification No. SW- SWR/MDB

Each 3303 47.51 3351.00

5-2-11 Supplying and erecting metal clad distribution board approved make 415/500V, 4 way, 32A. per way & neutral bar connector complete erected on iron frame/ wooden plank or Board as per specification No. SW- SWR/MDB

Each 4274 47.51 4322.00

5-2-12 Supplying and erecting metal clad distribution board approved make 415/500V, 6 way, 32A. per way & neutral bar connector complete erected on iron frame/ wooden plank or Board as per specification No. SW- SWR/MDB

Each 5330 47.51 5378.00

5-2-13 Supplying and erecting metal clad distribution board approved make 415/500V, 8 way, 32A. per way & neutral bar connector complete erected on iron frame/ wooden plank or Board as per specification No. SW- SWR/MDB

Each 6712 63.34 6775.00

5-2-14 Supplying and erecting mini feeder pillar triple pole with 200A FPMCCB as incomer and 2 outgoing circuits with HRC Fuse base and Cartridge of 100A consists of aluminium,bus bar 500 V 200 A. complete erected in 14 gauge CRCA sheet box with supporting angles, self locks, gasket and slanting top to be erected on provided foundation as per per specification No. SW-SWR/MFP

Each 31207 3545.04 34752.00

5-2-15 Supplying and erecting mini feeder pillar triple pole with 300A FPMCCB as incomer and 3 outgoing circuits with HRC Fuse base and Cartridge of 100A consists of aluminium,bus bar 500V 300A complete erected in 14 gauge CRCA sheet box with supporting angles, self locks, gasket and slanting top to be erected on provided foundation as per per specification No. SW-SWR/MFP

Each 47480 4011.66 51492.00

Page 34: Electrical CSR 12-13

Note :- 1) For erection of switchgear on existing/provided angle iron frame/wooden board reduce the over all rate by 5%. 2) In coastal area iron clad switchgear shall be invariably used. 3) For Switchgear without enclosure for cubical panels the rates shall be decreased by 25 % of item no 5-1-16 to 5-1-23 4) If 'A' grade switchgears the overall rate shall be increased by 15% for item No.5-1-16 to 5-1-23.

5.3 LT - - MCB's (MCB) 5-3-1 Supplying, erecting & marking SPMCB 0.5A to 5A in provided distribution

board as per specification No. SW-SWR/MCBEach 227 20.06 247.00

5-3-2 Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification No. SW- SWR/MCB

Each 156 20.06 176.00

5-3-3 Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification No. SW-SWR/MCB

Each 145 20.06 165.00

5-3-4 Supplying, erecting & marking SPMCB 40A to 63A C- series (for motor/power) in provided distribution board as per specification No. SW- SWR/MCB

Each 365 20.06 385.00

5-3-5 Supplying, erecting & marking SPMCB 40A to 63A, B- series (for lighting) in provided distribution board as per specification No. SW-SWR/MCB

Each 324 20.06 344.00

5-3-6 Supplying, erecting & marking DPMCB 6A to 32A, C- series (for motor/power) in provided distribution board as per specification No. SW- SWR/MCB

Each 530 20.06 550.00

5-3-7 Supplying, erecting & marking DPMCB 6 A to 32 A B- series (for lighting) in provided distribution board as per specification no. SW-SWR/MCB

Each 471 20.06 491.00

5-3-8 Supplying, erecting & marking DPMCB 40A to 63A, C- series (for motor/power) in provided distribution board as per specification No. SW- SWR/MCB

Each 775 20.06 795.00

5-3-9 Supplying, erecting & marking DPMCB 40A to 63A, B- series (for lighting) in provided distribution board as per specification No. SW-SWR/MCB

Each 757 20.06 777.00

5-3-10 Supplying, erecting & marking SPN MCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification No. SW- SWR/MCB

Each 476 20.06 496.00

5-3-11 Supplying, erecting & marking SPN MCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification No. SW- SWR/MCB

Each 434 20.06 454.00

5-3-12 Supplying, erecting & marking SPN MCB 40A, C-series (for lighting) in provided distribution board as per specification No. SW-SWR/MCB

Each 652 20.06 672.00

5-3-13 Supplying, erecting & marking SPN MCB 40A, B-series (for lighting) in provided distribution board as per specification No. SW-SWR/MCB

Each 605 20.06 625.06

5-3-14 Supplying, erecting & marking TPMCB 6 A to 32A in provided distribution board as per specification No. SW-SWR/MCB

Each 760 42.23 802.00

5-3-15 Supplying, erecting & marking TPMCB 40A to 63A in provided distribution board as per specification No. SW-SWR/MCB

Each 1169 42.23 1211.00

5-3-16 Supplying, erecting & marking FPMCB 6A to 32A in provided distribution board as per specification No. SW-SWR/MCB

Each 1074 42.23 1116.00

5-3-17 Supplying, erecting & marking FPMCB 40A to 63A in provided distribution board as per specification No. SW-SWR/MCB

Each 1542 42.23 1584.00

5-3-18 Supplying, erecting & marking TPN MCB 6A to 32A, C- series in provided distribution board as per specification No. SW-SWR/MCB

Each 1006 42.23 1048.00

5-3-19 Supplying, erecting & marking TPN MCB 40A to 63A, C- Series in provided distribution board as per specification No. SW-SWR/MCB

Each 1470 42.23 1512.00

5-3-20 Supplying erecting and marking double pole isolator only switch version of miniature circuit breaker (Conforming to IS:8828 of1996) of 40A with required wiring connections and lugs etc. in provided distribution board.

Each 302 20.06 322.00

5-3-21 Supplying erecting and marking triple pole isolators only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc. in provided distribution board.

Each 578 38.01 616.00

5-3-22 Supplying erecting and marking Triple pole isolators only switch version of miniature circuit breaker of 63A with required wiring connections and lugs etc. in provided distribution board.

Each 644 38.01 682.00

5-3-23 Supplying erecting and marking Triple pole isolators only switch version of miniature circuit breaker of 100A with required wiring connections and lugs etc. in provided distribution board.

Each 780 55.95 836.00

5-3-24 Supplying erecting and marking Four pole isolators only switch version of miniature circuit breakers of 40A in provided distribution board.

Each 697 55.95 753.00

5-3-25 Supplying erecting and marking Four pole isolators only switch version of miniature circuit breakers of 63A in provided distribution board.

Each 723 55.95 779.00

5-3-26 Supplying erecting and marking Four pole isolators only switch version of miniature circuit breakers of 80/100A in provided distribution board.

Each 905 63.34 968.00

Note :- 1) For lighting load 'B' series MCBs are to be provided and for motive power load 'C' series MCB s are to be provided 2) For heavy duty motors, welding transformers and machines having heavy surge current MCB of 'D' type series should be provided for which rates are to be taken by increasing 10% on the material cost of rates of 'C' series

Page 35: Electrical CSR 12-13

5.4 LT - - MCBDB's (MCBDB) 5-4-1 Supplying & erecting triple pole and neutral distribution board

(TPNDB) surface/ flush mounted, suitable for SPMCB of 12 ways, on iron frame/laminated board.(Horizontal type) as per specification No. SW- SWR/MCBDB

Each 1647 142.52 1790.00

5-4-2 Supplying & erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted SPMCB of 24 ways, on iron frame/laminated board.(Horizontal type) as per specification No. SW- SWR/MCBDB

Each 2288 142.52 2431.00

5-4-3 Supplying & erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted SPMCB of 36 ways, on iron frame/laminated board.(Horizontal type) as per specification No. SW- SWR/MCBDB

Each 2930 142.52 3073.00

5-4-4 Supplying & erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted SP (12 Poles)/TP (4 Poles) MCB of 4 ways (12 Poles), on iron frame/laminated board.(Vertical Busbar type) as per specification No. SW-SWR/MCBDB

Each 3894 142.52 4037.00

5-4-5 Supplying & erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted SP (24 Poles)/TP (8 Poles) MCB of 8 ways (24 Poles) on iron frame/laminated board. (Vertical Busbar type) as per specification No. SW-SWR/MCBDB

Each 5205 142.52 5348.00

5-4-6 Supplying & erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted SP (36 Poles)/TP (12 Poles) MCB of 12 ways (36 Poles) on iron frame/laminated board (Vertical Busbar type) as per specification No. SW-SWR/MCBDB

Each 6864 142.52 7007.00

5-4-7 Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SPMCB of 12 ways, on iron frame/laminated board.(Horizontal type) as per specification No. SW- SWR/MCBDB

Each 2402 142.52 2545.00

5-4-8 Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SPMCB of 24 ways, on iron frame/laminated board.(Horizontal type) as per specification No. SW- SWR/MCBDB

Each 3566 142.52 3709.00

5-4-9 Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SPMCB of 12 ways (36 Poles) on iron frame/laminated board. (Horizontal Busbar type) as per specification no. SW-SWR/MCBDB

Each 4876 142.52 5019.00

5-4-10 Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SP (12 Poles)/TP (4 Poles) MCB of 4 ways (12 Poles), on iron frame/laminated board.(Vertical Busbar type) as per specification No. SW-SWR/MCBDB

Each 5694 142.52 5837.00

5-4-11 Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SP (24 Poles)/TP (8 Poles) MCB of 8 ways (24 Poles) on iron frame/laminated board. (Vertical Busbar type) as per specification No. SW-SWR/MCBDB

Each 6923 142.52 7066.00

5-4-12 Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SP (36 Poles)/TP (12 Poles) MCB of 12 ways (36 Poles) on iron frame/laminated board. (Vertical Busbar type) as per specification No. SW-SWR/MCBDB

Each 8660 142.52 8803.00

5-4-13 Supplying, erecting and marking enclosure Single pole and neutral distribution board (SPNDB) one way for SPMCB 1 No on iron frame/laminated board as per specification No. SW-SWR/MCBDB

Each 199 22.17 221.00

5-4-14 Supplying and erecting single pole and neutral distribution board (SPNDB) surface/flush mounted with 2 ways for incoming and 4 ways for outgoing SPMCBs on iron frame/laminated board, as per specification no. SW-SWR/MCBDB

Each 653 41.17 694.00

5-4-15 Supplying and erecting single pole and neutral distribution board (SPNDB) surface/flush mounted with 2 ways for incoming and 8 ways for outgoing SP MCB’s on iron frame/laminated board as per specification No. SW-SWR/MCBDB

Each 837 41.17 878.00

5-4-16 Supplying and erecting single pole and neutral distribution board (SPNDB) surface/flush mounted with 2 ways for incoming and 12 ways for outgoing SP MCB’s on iron frame/laminated board as per specification No. SW-SWR/MCBDB

Each 1058 41.17 1099.00

5-4-17 Supplying and erecting single pole and neutral distribution board (SPNDB) with door surface/flush mounted with 2 ways for incoming and 4 ways for outgoing SP MCB’s on iron frame/laminated board as per specification No. SW-SWR/MCBDB

Each 1043 41.17 1084.00

5-4-18 Supplying and erecting single pole and neutral distribution board (SPNDB) with door surface/flush mounted with 2 ways for incoming and 8 ways for outgoing SP MCB’s on iron frame/laminated board as per specification No. SW-SWR/MCBDB

Each 1308 41.17 1349.00

5-4-19 Supplying and erecting single pole and neutral distribution board (SPNDB) with door surface/flush mounted with 2 ways for incoming and 12 ways for outgoing SP MCB’s on iron frame/laminated board as per specification No. SW-SWR/MCBDB

Each 1675 41.17 1716.00

Page 36: Electrical CSR 12-13

5-4-20 Supplying & erecting original 1.25 mm CRCA sheet metal enclosures with 20A. 2 pin plug & earth socket and 20A. 3 pin plug top with 20A/30A single pole MCB complete erected on angle iron frame.

Each 896 47.51 944.00

5-4-21 Supplying & erecting original 1.25 mm CRCA sheet metal enclosures with 30 A, 3 pin plug & earth socket and 30 A 3 pin plug top with 30 A. triple pole MCB complete erected on angle iron frame.

Each 1732 47.51 1780.00

5-4-22 Supplying & erecting original 1.25 mm CRCA sheet metal enclosures with 10A. 2 pin plug and earth socket and 10A, 3 pin plug top with 10A single pole miniature circuit breakers complete erected on angle iron frame.

Each 884 41.17 925.00

5-4-23 Supplying & erecting CRCA sheet metal one way enclosures suitable for D.P.M.C.B. /T.P. M.C.B. /F.P M.C.B. complete erected on angle iron frame.

Each 339 24.28 363.00

5-4-24 Supplying and erecting blanking plate of suitable size on MCB DB Each 14 0 14.00 5-4-25 Supplying & erecting triple pole and neutral distribution board (TPNDB)

with door surface/ flush mounted suitable for 3 Pole MCCB as Incommer & outgoing SP MCB (12 Poles) or TP MCB of 4 ways (12 Poles) on iron frame. (Vertical Busbar type) as per specification no. SW- SWR/MCBDB1

Each 6157 195.3 6352.00

5-4-26 Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted suitable for 3 Pole MCCB as Incommer & outgoing SP MCB (24 Poles) or TP MCB of 8 ways (24 Poles) , on iron frame. (Vertical Busbar type) as per specification No. SW- SWR/MCBDB1

Each 7162 195.3 7357.00

5-4-27 Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted suitable for 3 Pole MCCB as Incommer & outgoing SP MCB (36 Poles) or TP MCB of 12 ways (36 Poles) on iron frame. (Vertical Busbar type) as per specification No. SW- SWR/MCBDB1

Each 8284 195.3 8479.00

Note :- 1) All MCB's shall have breaking capacity not less than 10 kA. 2) Above rates are applicable only to factory made enclosures. 3) Reduce overall rates by 5% if angle iron frame is not required. 4) MCB's ( double pole, four pole or triple pole & neutral) & isolators for single phase circuits shall not be incorporated for outgoing circuits of three phase distribution board. 5) For more than 5 kW load RCCB/ELCB shall invariably be provided & erected on the same distribution board. (RCCB/ELCB+MCB) or (RCCB/ELCB+MCCB etc,) separate box for RCCB/ELCB is not permissible. 6) Above rates are for branded DB's with provision of same brand interior switchgears and if other than branded are used reduce material rate by 10% . 7) The MCBDB is exclusive of incoming MCB/MCCB and outgoing SP/TP MCB's and the same should be preferably of the same make

5.5 LT - - MCCB's (MCCB) 5-5-1 Providing & erecting 3 Pole MCCB upto 100A of 25kA SC rating, thermal

and magnetic setting with provided leads on iron frame/laminated board as per specification No. SW-SWR/MCCB

Each 4701 630.25 5331.00

5-5-2 Providing & erecting 3 Pole MCCB of 200A. capacity with S.C. rating 35 kA thermal and magnetic setting with provided leads on iron frame/laminated board as per specification no. SW-SWR/MCCB

Each 10738 661.92 11400.00

5-5-3 Providing & erecting 3 Pole MCCB of 250A. capacity with S.C. rating of 35 kA,thermal and magnetic setting with provided leads on iron frame/laminated board as per specification No. SW-SWR/MCCB

Each 15600 661.92 16262.00

5-5-4 Providing & erecting 3 Pole MCCB of 400A. capacity with S.C. rating of 50 kA ,thermal and magnetic setting with provided leads on iron frame as per specification No. SW-SWR/MCCB

Each 21945 661.92 22607.00

5-5-5 Providing & erecting 3 Pole MCCB of 600/630 A. capacity with S C rating of 50 kA ,thermal and magnetic setting with provided leads on iron frame as per specification No. SW-SWR/MCCB

Each 26265 1025.08 27290.00

5-5-6 Providing & erecting 3 Pole MCCB of 800A. capacity with S C rating of 50 kA, thermal and magnetic setting with provided leads on iron frame as per specification No. SW-SWR/MCCB

Each 31687 1103.21 32790.00

Note :- 1) For erecting earth leakage relay along with breaker add Rs. 750/- for shunt release coil 2) For use of 4pole MCCB in place of 3pole MCCB add 30% in overall rate of 3 pole MCCB. 3) For MCCB with variable setting, increase overall rate by 25%

5.6 RCCB (RCCB) 5-6-1 Providing, erecting & commissioning RCCB only of electro magnetic

type with 20 kA breaking capacity of 16/25 A. 2 pole complete as per specification No. SW-RCCB/RCCB

Each 1894 174.19 2068.00

5-6-2 Providing, erecting & commissioning RCCB only of electro magnetic type with 20 kA breaking capacity of 40 A. 2 pole complete as per specification No. SW-RCCB/RCCB

Each 2668 174.19 2842.00

Page 37: Electrical CSR 12-13

5-6-3 Providing, erecting & commissioning RCCB only of electro magnetic type with 20 kA breaking capacity of 63 A. 2 pole complete as per specification No. SW-RCCB/RCCB

Each 3462 174.19 3636.00

5-6-4 Providing, erecting & commissioning RCCB only of electro magnetic type with 20 kA breaking capacity of 16/25A. 4 pole complete as per specification No. SW-RCCB/RCCB

Each 3228 174.19 3402.00

5-6-5 Providing, erecting & commissioning RCCB only of electro magnetic type with 20 KA breaking capacity of 40A. 4 pole complete as per specification No. SW-RCCB/RCCB

Each 3306 174.19 3480.00

5-6-6 Providing, erecting & commissioning RCCB of electro magnetic type with 20 kA breaking capacity of 63A. 4 pole complete as per specification No. SW-RCCB/RCCB

Each 3815 174.19 3989.00

5-6-7 Providing, erecting & commissioning RCCB of electro magnetic type with 20 kA breaking capacity of 80A. 4 pole complete as per specification No. SW-RCCB/RCCB

Each 5318 174.19 5492.00

5-6-8 Providing, erecting & commissioning approved make RCCB of electro magnetic type with 20 kA breaking capacity of 100A, 4 pole complete as per specification No. SW-RCCB/RCCB

Each 5318 174.19 5492.00

5-6-9 Supplying, fixing and commissioning RCCB+MCB, electro magnetic type 6 kA. breaking capacity of 6/10/16/20/25A, 2 Pole, 1 Phase as per specification No. SW-RCCB/RCCB

Each 2359 174.19 2533.00

5-6-10 Supplying, fixing and commissioning RCCB+MCB, electro magnetic type 6 kA. breaking capacity of 32A/40A 2 Pole 1 phase as per specification No. SW-RCCB/RCCB

Each 3099 174.19 3273.00

5-6-11 Supplying, fixing and commissioning RCCB+MCB, electro magnetic type 6 kA. breaking capacity of 63A, 2 Pole 1 Phase as per specification No. SW-RCCB/RCCB

Each 2593 174.19 2767.00

5-6-12 Supplying, fixing and commissioning RCCB+MCB, electro magnetic type 6 kA. breaking capacity of 6A/10A/16A/20A/25/A 4 Pole 3 phase as per specification No. SW-RCCB/RCCB

Each 3346 174.19 3520.00

5-6-13 Supplying, fixing and commissioning RCCB+MCB, electro magnetic type 6 kA. breaking capacity of 32A/40A 4 Pole 3 phase as per specification No. SW-RCCB/RCCB

Each 3449 142.52 3592.00

5-6-14 Supplying, fixing and commissioning RCCB+MCB, electro magnetic type 6 kA. breaking capacity of 63A 4 Pole 3 phase as per specification No. SW-RCCB/RCCB

Each 3099 174.19 3273.00

5-6-15 Supplying & fixing CRCA sheet Box with earthing terminals for housing 2 Pole RCCB/RCCB+MCB complete on iron frame/laminated board.

Each 145 20.06 165.00

5-6-16 Supplying & fixing CRCA sheet Box with earthing terminals for housing 4 Pole RCCB/RCCB+MCB complete on iron frame/laminated board.

Each 207 20.06 227.00

5-6-17 Deleted 5-6-18 Deleted 5-6-19 Deleted

5.7 MCCB Panel Boards and accessories (SWR-MCCBPB) 5-7-1 Providing & erecting Floor / Wall mounting, MCCB Panel board suitable for

Four Pole Incoming 250A, 2 ways Four pole outgoing on provided iron frame, as per Specification No SW-SWR/MCCBPB.(Excluding MCCB'S)

Each 27475 850.89 28326.00

5-7-2 Providing & erecting Floor / Wall mounting, MCCB Panel board suitable for Four Pole Incoming 250A, 4 ways Four pole outgoing on provided iron frame, as per Specification No SW-SWR/MCCBPB. (Excluding MCCB'S)

Each 34136 850.89 34987.00

5-7-3 Providing & erecting Floor / Wall mounting, MCCB Panel board suitable for Four Pole Incoming 250A, 6 ways Four pole outgoing on provided iron frame, as per Specification No SW-SWR/MCCBPB. (Excluding MCCB'S)

Each 40293 850.89 41144.00

5-7-4 Providing & erecting Floor / Wall mounting, MCCB Panel board suitable for Four Pole Incoming 250A, 8 ways Four pole outgoing on provided iron frame, as per Specification No SW-SWR/MCCBPB. (Excluding MCCB'S)

Each 43081 1240.45 44321.00

5-7-5 Providing & erecting Floor / Wall mounting, MCCB Panel board suitable for Four Pole Incoming 250A, 12 ways Four pole outgoing erected on provided iron frame, as per Specification No SW-SWR/MCCBPB. (Excluding MCCB'S)

Each 63168 1631.06 64799.00

5-7-6 Providing & erecting Floor / Wall mounting, MCCB Panel board suitable for Four Pole Incoming 400A, 2 ways Four pole outgoing on provided iron frame, as per Specification No SW-SWR/MCCBPB. (Excluding MCCB'S)

Each 34141 850.89 34992.00

5-7-7 Providing & erecting Floor / Wall mounting, MCCB Panel board suitable for Four Pole Incoming 400A, 4 ways Four pole outgoing on provided iron frame, as per Specification No SW-SWR/MCCBPB. (Excluding MCCB'S)

Each 40567 850.89 41418.00

5-7-8 Providing & erecting Floor / Wall mounting, MCCB Panel board suitable for Four Pole Incoming 400 A, 6 ways Four pole outgoing on provided iron frame, as per Specification No SW-SWR/MCCBPB. (Excluding MCCB'S)

Each 46702 850.89 47553.00

5-7-9 Providing & erecting Floor / Wall mounting, MCCB Panel board suitable for Four Pole Incoming 400A, 8 ways Four pole outgoing on provided iron frame, as per Specification No SW-SWR/MCCBPB. (Excluding MCCB'S)

Each 49507 1240.45 50747.00

5-7-10 Providing & erecting Floor / Wall mounting, MCCB Panel board suitable for Four Pole Incoming 400A, 12 ways Four pole outgoing on provided iron frame, as per Specification No SW-SWR/MCCBPB. (Excluding MCCB'S)

Each 69577 1631.06 71208.00

Page 38: Electrical CSR 12-13

5-7-11 Providing & erecting Incoming and Outgoing Cable Alleys suitable for MCCB panel board of 250A incoming and 2 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and basic DB.

Set. 11482 156.24 11638.00

5-7-12 Providing & erecting Incoming and Outgoing Cable Alleys suitable for MCCB panel board of 250A incoming and 4 way outgoing or 400A incoming and 2 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and basic DB.

Set. 13322 156.24 13478.00

5-7-13 Providing & erecting Incoming and Outgoing Cable Alleys suitable for MCCB panel board of 250A incoming and 6 way outgoing or 400A incoming and 4 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and basic DB.

Set. 15315 156.24 15471.00

5-7-14 Providing & erecting Incoming and Outgoing Cable Alleys suitable for MCCB panel board of 250A incoming and 8 way outgoing or 400A incoming and 6 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and basic DB.

Set. 15315 156.24 15471.00

5-7-15 Providing & erecting Incoming and Outgoing Cable Alleys suitable for MCCB panel board of 250A incoming and 12 way outgoing or 400A incoming and 6/8 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and basic DB.

Set. 17588 156.24 17744.00

5-7-16 Providing & erecting Incoming and Outgoing Cable Alleys suitable for MCCB panel board of 400A incoming and 12 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and basic DB.

Set. 20684 156.24 20840.00

Note :- 1) The MCCB panel board and cable alleys from above items are interconnected and should be of same make only and factory made only 2) The MCCB panel board is exclusive of incoming and outgoing MCCB's and the same should be preferably of the same make 3) In the MCCB panel both FP/TP MCCB's as incomer and FP/TP/ SP MCCB's can be provided as outgoing

5.8 LT - - Air Circuit Breakers (ACB) 5-8-1 Deleted 5-8-2 Supplying and erecting Air circuit breaker manually operated non-

drawout type of 630A, 500V, 3 pole with standard acccessories on provided iron frame as per specification No. SW-SWR/ACB

Each 57282 2063.89 59346.00

5-8-3 Supplying and erecting Air circuit breaker manually operated non- drawout type of 800A, 500V, 3 pole with standard acccessories on provided iron frame as per specification No. SW-SWR/ACB

Each 65940 2253.92 68194.00

5-8-4 Supplying and erecting Air circuit breaker manually operated non- drawout type of 1000A, 500V, 3 pole with standard acccessories on provided iron frame as per specification No. SW-SWR/ACB

Each 67804 2253.92 70058.00

5-8-5 Supplying and erecting Air circuit breaker manually operated non- drawout type of 1600A, 500V, 3 pole with standard acccessories on provided iron frame as per specification No. SW-SWR/ACB

Each 93200 2253.92 95454.00

5-8-6 Supplying and erecting Air circuit breaker manually operated drawout type of 800A, 500V, 3 pole with standard acccessories on provided iron frame as per specification No. SW-SWR/ACB

Each 108031 2253.92 110285.00

5-8-7 Supplying and erecting Air circuit breaker manually operated drawout type of 1000A, 500V, 3 pole with standard acccessories on provided iron frame as per specification No. SW-SWR/ACB

Each 112941 2253.92 115195.00

5-8-8 Supplying and erecting Air circuit breaker manually operated drawout type of 1600A, 500V, 3 pole with standard acccessories on provided iron frame as per specification No. SW-SWR/ACB

Each 142364 2253.92 144618.00

5-8-9 (New)

Supplying and erecting Air circuit breaker manually operated drawout type of 1250 A, 500V, 3 pole with standard acccessories on provided iron frame as per specification No. SW-SWR/ACB

Each 88539 2253.92 90793.00

5-8-10 (New)

Supplying and erecting Air circuit breaker manually operated Non drawout type of 1250A, 500V, 3 pole with standard acccessories on provided iron frame as per specification No. SW-SWR/ACB

Each 131756 2253.92 134010.00

5.9 HT SF6 Load Break Switch , VCB (HTS) 5-9-1 Supplying and erecting approved make extendable / non-extendable type

11 kV, 630A, load break switch with fuses of required rating, on provided MS channels / trench / foundation in an approved manner as per specification no SW-HTS / LBS

Each 123627 9455.9 133083.00

Page 39: Electrical CSR 12-13

5-9-2 Supplying and erecting approved make extendable / non-extendable type 22 kV, 630A, load break switch with fuses of required rating, on provided MS channels / trench / foundation in an approved manner as per specification no SW-HTS / LBS

Each 234464 9455.9 243920.00

5-9-3 Supplying and erecting approved make extendable / non-extendable type 11 kV 630A, Load break Isolator switch on provided MS channels / trench / foundation in an approved manner as per specification no SW-HTS / LBS

Each 143875 9455.9 153331.00

5-9-4 Supplying and erecting approved make extendable / non-extendable type 22 kV 630A, load break Isolator switch on provided MS channels / trench / foundation in an approved manner as per specification no SW-HTS / LBS

Each 266436 9455.9 275892.00

5-9-5 Supplying and erecting approved make 11 kV 400A, Oil Switch-Fuse unit extendable/non-extendable on provided MS channels / trench / foundation in an approved manner as per specification no SW-HTS / LBS

Each 150099 9455.9 159555.00

5-9-6 Supplying & erecting 11 kV 630A, Indoor type Ring Main unit with 1or 2 Incoming & 2 or 1 Outgoing with HRC fuses complete erected on provided cc foundation/MS channels/trench, etc, in an approved manner as per specification no SW-HTS / RMU

Each 330382 94228.61 424611.00

5-9-7 Supplying & erecting 22 kV 630A, Indoor type Ring Main unit with 1or 2 Incoming & 2 or 1 Outgoing with HRC fuses complete erected on provided c c foundation/MS channels/trench, etc, in an approved manner as per specification no SW-HTS / RMU

Each 628791 9455.9 638247.00

5-9-8 Supplying and erecting approved make 11kV, 630A, Vacuum Circuit breaker of required rating, on provided MS channels / trench / foundation in an approved manner as per specification no SW-HTS / VCB

Each 530251 9455.9 539707.00

5-9-9 Supplying and erecting approved make 22 kV, 630 A, Vacuum Circuit breaker of required rating, on provided MS channels / trench / foundation in an approved manner as per specification no SW-HTS / VCB

Each 826853 9455.9 836309.00

5-9-10 Supplying and erecting 11kV HRC Fuse 10A to 40 A for load break switch to be fitted with necessary nut bolts and commissioning complete.

Each 3237 40.12 3277.00

5-9-11 Supplying and erecting11kV HRC Fuse 63A for load break switch to be fitted with necessary nut bolts and commissioning complete.

Each 6897 40.12 6937.00

5-9-12 Supplying and erecting22kV HRC Fuse 10A to 30A for load break switch to be fitted with necessary nut bolts and commissioning complete.

Each 7882 40.12 7922.00

5-9-13 Supplying and erecting22 kV HRC Fuse 63A for load break switch to be fitted with necessary nut bolts and commissioning complete.

Each 8727 40.12 8767.00

Note :- 1) The above items are for Indoor installation with IP 55 Protection Class. 2) For outdoor installations IP 65 Protection Class is to be proposed by increasing overall rates by 10%.

5.10 Accessories (AS) 5-10-1 Supplying and erecting porcelain base iron clad cut out of H.C. type 500V

16A approved make erected on polished wooden block.Each 147 9.5 157.00

5-10-2 Supplying and erecting Iron clad cut out H.C. type 500V 32A approved make erected on polished wooden block.

Each 161 9.5 171.00

5-10-3 Supplying and erecting Iron clad cut out H.C. type 500V 63A approved make erected on polished wooden block.

Each 329 9.5 339.00

5-10-4 Supplying and erecting Iron clad cut out H.C. type 500V 100A approved make erected on polished wooden block.

Each 602 16.89 619.00

5-10-5 Supplying and erecting Iron clad cut out H.C. type 500V 200A approved make erected on polished wooden block.

Each 1215 16.89 1232.00

5-10-6 Supplying and erecting H.C. pattern porcelain fuse bridges with base & HC type fuse links 250V 16A approved make erected on polished wooden block.

Each 27 6.33 33.00

5-10-7 Supplying and erecting H.C. pattern porcelain fuse bridges with base & HC type fuse links 250V 32A approved make erected on polished wooden block.

Each 73 6.33 79.00

5-10-8 Supplying & erecting fuse bridge with base 16A erected on provided switch board in approved manner.

Each 30 2.11 32.00

5-10-9 Supplying & erecting fuse bridges with base H.C. type fuse links 250/500V 63A erected on polished wooden block.

Each 159 10.56 170.00

5-10-10 Supplying & erecting fuse bridges with base H.C. type fuse links 250/500V 100A erected on polished wooden block.

Each 257 16.89 274.00

5-10-11 Supplying & erecting fuse bridges with base H.C. type fuse links 250/500V 200A erected on polished wooden block.

Each 433 16.89 450.00

5-10-12 Supplying & erecting fuse bridges with base H.C. type fuse links 250/500V 300A erected on polished wooden block.

Each 524 16.89 541.00

5-10-13 Supplying and erecting bakelite fuse fitting suitable for HRC bolted type fuse up to 32A without fuse.

Each 145 13.72 159.00

5-10-14 Supplying and erecting bakelite fuse fitting suitable for HRC bolted type fuse up to 63A without fuse.

Each 194 14.78 209.00

5-10-15 Supplying and erecting bakelite fuse fitting suitable for HRC bolted type fuse up to 100A without fuse.

Each 490 15.84 506.00

5-10-16 Supplying & erecting ISI marked HRC fuse cartridge 500V 32A Each 56 10.56 67.00 5-10-17 Supplying & erecting ISI marked HRC fuse cartridge 500V 63 A Each 70 10.56 81.00 5-10-18 Supplying & erecting ISI marked HRC fuse cartridge 500V 100A Each 153 10.56 164.00

Page 40: Electrical CSR 12-13

5-10-19 Supplying & erecting ISI marked HRC fuse cartridge 500V 200A Each 221 10.56 232.00 5-10-20 Supplying & erecting ISI marked HRC fuse cartridge 500V 300A Each 300 10.56 311.00 5-10-21 Supplying & erecting ISI marked HRC fuse cartridge 500V 400A Each 700 10.56 711.00 5-10-22 Supplying & erecting approved make 500V 16A porcelain base neutral

link complete erected in provided M.S. box.Each 48 8.45 56.00

5-10-23 Supplying & erecting approved make 500V 32A porcelain base neutral link complete erected in provided M.S. box.

Each 70 8.45 78.00

5-10-24 Supplying & erecting approved make 500V 63A porcelain base neutral link complete erected in provided M.S. box.

Each 105 8.45 113.00

5-10-25 Supplying & erecting approved make 500V 100A porcelain base neutral link complete erected in provided M.S. box.

Each 190 14.78 205.00

5-10-26 Supplying & erecting approved make porcelain/epoxy bus bar support complete erected in provided M.S. box for 100A

Each 30 7.39 37.00

5-10-27 Supplying & erecting approved make porcelain/epoxy bus bar support complete erected in provided M.S. box for 200/300A

Each 54 7.39 61.00

5-10-28 Supplying & erecting approved make porcelain/epoxy bus bar support complete erected in provided M.S. box for 400A

Each 74 7.39 81.00

5-10-29 (New)

Supplying & erecting approved make 500V 200A porcelain base neutral link complete erected in provided M.S. box.

Each 342 14.78 357.00

5.11 Dismantling 5-11-1 Dismantling the existing switchgears, DB, and Bus bar of any size

complete with/ without board or angle iron frameEach 0 10.56 11.00

5-11-2 Making the site clear of dismantled DB and switch gears by refilling the holes with cement mortar & finishing in an approved manner.

Each 5 5.28 10.00

5-11-3 Dismantling existing OCB, ACB,LBS,VCB complete from existing panel board in an approved manner.

Each 0 71.79 72.00

Note :- The rates for item no 5.11.1 to 5.11.3 are for dismantling and handing over to section office inclusive of transportation upto 25 km, between site and section office.

Chapter : 6 CONTROL PANEL (CP) 6.1 Sheets (SH)

6-1-1 CRCA sheet 2mm (14 gauge) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, rivetting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.

Sqm. 1580 278.7 1859.00

6-1-2 CRCA sheet 1.6mm (16 gauge) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, rivetting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.

Sqm. 1304 278.7 1583.00

6-1-3 G.I. sheet 1.6mm (16 gauge) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, rivetting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.

Sqm. 1634 278.7 1913.00

6-1-4 G.I. sheet 1.25mm (18gauge) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, rivetting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.

Sqm. 1343 278.7 1622.00

6-1-5 G.I. sheet 1mm (20 gauge) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, rivetting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.

Sqm. 1112 217.47 1329.00

6-1-6 G.I. sheet 0.8mm (22 gauge) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, rivetting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.

Sqm. 934 166.8 1101.00

6-1-7 G.I. sheet 0.6mm (24 gauge) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, rivetting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.

Sqm. 790 217.47 1007.00

Note :- Increase overall rate by 30% for CRCA & GI sheets measuring less than one sq. m. for total items in each estimate.

6-1-8 Acrylic sheet 3 mm thick to be used for covering the CRCA sheet boxes etc. including cutting, drilling, & pasting or fixing with nut bolts/ screws etc. complete.

Sqm. 1104 99.24 1203.00

6-1-9 Acrylic sheet 2 mm thick for covering wall entries including cutting drilling and fixing with nut bolts / screws etc. complete

Sqm. 806 99.24 905.00

6-1-10 Supplying and erecting Hylam sheet/ Ebonite sheet 3 mm thick for covering wall entries including cutting drilling and fixing with nut bolts / screws etc. complete.

Sqm. 706 99.24 805.00

6-1-11 Supplying and erecting Hylam sheet/ Ebonite 6 mm thick for covering wall entries including cutting drilling and fixing with nut bolts / screws etc. complete.

Sqm. 1303 99.24 1402.00

6-1-12 Supplying and erecting Plywood 6 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete.

Sqm. 300 78.12 378.00

6-1-13 Supplying and erecting Plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete.

Sqm. 576 71.79 648.00

6-1-14 Supplying & pasting Sunmica/ Formica sheet 1 mm thick on provided Plywood of required shade.

Sqm. 469 123.52 593.00

Page 41: Electrical CSR 12-13

6-1-15 Supplying and erecting marine Plywood 19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete.

Sqm. 1043 123.52 1167.00

6-1-16 Supplying and erecting enamel iron G.I. sheet 1.25mm (18 gauge) caution board of size 200 x 150 mm. as per I.S. 2551 of 1982 in Marathi and Hindi erected at position.

Each 88 24.28 112.00

6-1-17 Supplying and erecting G.I. sheet of 1.25mm (18gauge) size 200 x 150 mm. duly painted with red oxide & enamel paint for displaying the department & date of erection of the electrical installation with approved shade as specified by the authority.

Each 31 29.56 61.00

6-1-18 Providing and erecting cupboard for enclosing switchgears or for any other purpose made from selected marine plywood planks 19 mm. thick duly varnished/ painted from inside and from outside with brass hinges and locking arrangement with suitable lock with duplicate keys. Cupboard duly grouted with suitable size of iron work in wall at the bottom. (Size of cupboard shall be specified in the estimate)

Sqm. 2103 496.18 2599.00

6-1-19 Supplying and erecting Iron work for panel board or other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority (Size of angle/flat/channel iron to be specified in estimate)

Kg. 96 25.34 121.00

6-1-20 Supplying and erecting self locking arrangement with duplicate keys, made of brass duly erected, flush with surface of panel/cupboard.

Each 148 29.56 178.00

6-1-21 Supplying and erecting expanded metal jali enclosure made from G.I. square mesh 15 SWG having 20/25 mm square, complete, properly fixed/welded and duly painted with one coat of red oxide and two coats of silver/enamel paint (size of jali or enclosure to be specified in the estimate.)

Sqm. 199 24.28 223.00

6.2 Bus bars (BB) 6-2-1 Supplying and erecting Bus bar chamber triple pole with neutral with four

aluminium bars, 500V, 100A complete as per specification no. CP-BBMtr. 3241 436 3677.00

6-2-2 Supplying and erecting Bus bar chamber triple pole with neutral with four aluminium bars, 500V 200A complete as per specification no. CP-BB

Mtr. 3435 436 3871.00

6-2-3 Supplying and erecting Bus bar chamber triple pole with neutral with four aluminium bars, 500V 300A complete as per specification no. CP-BB

Mtr. 3585 436 4021.00

6-2-4 Supplying and erecting Bus bar chamber triple pole with neutral with four aluminium bars, 500V 400A complete as per specification no. CP-BB

Mtr. 5600 436 6036.00

6-2-5 Supplying and erecting Bus bar chamber triple pole with neutral with four aluminium bars, 500V 630A complete as per specification no. CP-BB

Mtr. 8953 436 9389.00

6-2-6 Supplying and erecting Bus bar chamber triple pole with neutral with four aluminium bars, 500V 800A complete as per specification no. CP-BB

Mtr. 10004 436 10440.00

6-2-7 Supplying and erecting Bus bar chamber triple pole with neutral with four Copper bars, 500V, 100A complete as per specification no. CP-BB

Mtr. 4627 436 5063.00

6-2-8 Supplying and erecting Bus bar chamber triple pole with neutral with four Copper bars, 500V 200A complete as per specification no. CP-BB

Mtr. 5497 436 5933.00

Note :- 1) Nut, bolts holding the lugs to bus bar shall be of bimetallic/brass/cadmium plated steel. 2) Double/more bus bars shall be adequately bolted. 3) In fabrication of bus bar chamber if angle iron frame is not provided, deduct 20% from overall rate. 4) The rates for item no 6-2-1 to 6-2-8 are for 1 meter length of bus bar.

6.3 Measuring Instruments 6-3-1 Supplying and erecting Static energy meter with impulse counter

230V 50 cycles A.C. supply 5/10/20A, ISI mark, complete erected on polished T.W. board duly wired with required size of weather proof PVC wires duly tested for class II accuracy by electric supply company.

Each 2833 124.57 2958.00

6-3-2 Supplying & erecting Static energy meter 230V, 50 cycles AC supply 5/10/20/40 A Class I accuracy I.S.I. marked with metal/polycarbonate enclosure. Meter with LCD/ LED display complete erected on polished T.W. board duly wired with required size of weather proof PVC wires duly tested for classII accuracy by electric supply company.

Each 3177 124.57 3302.00

6-3-3 Supplying & erecting Static Energy meter 440V 50 cycles AC supply 3 phase 4 wire 10/20/25/30A class I accuracy I.S.I.marked with metal/polycarbonate encloser. Meter with LCD / LED display complete erected on polished T.W. board duly wired with required size of weather proof PVC wires duly tested for class II accuracy by electric supply company.

Each 5033 158.36 5191.00

6-3-4 Supplying and erecting Static Energy meter 440-V 50 cycles A.C. 3 phase 4 wires 50A ISI mark meter with LCD/LED Display complete erected on polished T.W. board duly wired with required size of weather proof PVC wires duly tested for class II accuracy by electric supply company.

Each 5446 158.36 5604.00

Page 42: Electrical CSR 12-13

6-3-5 Supplying and erecting kWH meter provided with maximum kW demand indicator for unbalanced load 3 phase 4 wire 50 cycles 230/440V AC supply with incorporated time switch of 30 minutes integration period and of 15 seconds tune required for decoupling, suitable to work on provided three numbers of instrument current transformers of class C accuracy with ratio 100/5 A -400/5 A complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs.

Each 14609 281.87 14891.00

6-3-6 Providing and erecting Analog type moving iron voltmeter for A.C Voltage 0 to 500V range, 50Hz, Accuracy class 1.5, flush type; on provided box / panel and connected with necessary PVC wire leads and lugs.

Each 622 124.57 747.00

6-3-7 Providing and erecting Analog type moving iron Ammeter for A.C current 0-30 A, direct range, 500V.Accuracy class 1.5, flush type on provided box/ panel and connecting with necessary PVC wire leads and lugs.

Each 492 124.57 617.00

6-3-8 Providing and erecting Analog type moving iron Ammeter for A.C current CT operated of suitable size in scale between 0 to 1000A, 500V accuracy class 1.5, flush type; on provided box /panel and connecting with provided CTs and necessary PVC wire leads and lugs.

Each 679 124.57 804.00

6-3-9 Supplying and erecting RKVAH meter 3 phase 4 wire 400 V. 50 cycles suitable for unbalanced load suitable to work on provided current transformer (3 Nos.) 100/5 Amp to 400/5A ratio with zero adjustment complete erected on provided M.S. box and connected to C.T.s.

Each 10316 281.87 10598.00

6-3-10 Supplying and erecting Power Factor Meter 150 mm. dia. flush or projection type suitable for 400V. 50 cycles 3 phase 4 wire balanced or unbalanced load to work with appropriately provided C.T.s 100/5A to 400/5A ratio and otheraccessories complete erected in provided M.S. box and connected to the circuit by means of PVC copper wire leads.

Each 6803 281.87 7085.00

6-3-11 Supplying and erecting panel mounting type digital ammeter having Three and half digit LED display, external C.T. operated, calibrated for 0 to 1000A AC suitable to operate on 500V AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

Each 1159 158.36 1317.00

6-3-12 Supplying and erecting panel mounting type digital voltmeter having Three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

Each 1159 158.36 1317.00

6-3-13 Supplying and erecting digital frequency meter of 3 digit LED display having 0 to 100 Hz range suitable to operate on 500V AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

Each 1835 158.36 1993.00

Note :- While framing the estimate for P.F. meter / RKVAH meter, provision of 3 CTs should invariably be made separately. All meters shall be with manufacturer's calibration certificate.

6.4 H.T.Metering 6-4-1 Deleted Each 6-4-2 Supplying, erecting, testing, commissioning 11 KV H.T. metering cubical

(Compact Type) approved by MSEDCL/Licensee fabricated with 2mm.(14 SWG) M.S.sheets with supporting angle and channel, painted with powder coating / epoxy paint of required shade copper bus bar size 25x6 mm electronic security lock and heavy duty mechanical lock, with counter meter for measuring no of times the opening of doors, top side cover ( C.T.P.T COVER) interlock with meter doors, epoxy coated 3 nos C.T having required ratio between 5/5A to 100/5A burden 10 VA class 0.5 I.L.12/28/75 KVP epoxy terminal block suitable for provided trivector meter, and provision for incoming and outgoing cables etc complete duly tested by Licensee with necessary Test Certificates and erected on provided plinth/ C.C foundation

Each 149097 7063.69 156161.00

6-4-3 Supplying, erecting, testing, commissioning 22 kV H.T. metering cubical (Compact Type) approved by MSEDCL/Licensee fabricated with 2mm.(14 SWG) M.S.sheets with supporting angle and channel, painted with powder coating / epoxy paint of required shade copper bus bar size 25x6 mm electronic security lock and heavy duty mechanical lock, with counter meter for measuring no of times the opening of doors, top side cover ( C.T.P.T COVER) interlock with meter doors, epoxy coated 3 nos C.T having required ratio between 5/5A to 100/5A burden 10 VA class 0.5 I.L.12/28/75 KVP epoxy terminal block suitable for provided trivector meter, and provision for incoming and outgoing cables etc complete duly tested by Licensee with necessary Test Certificates and erected on provided plinth/ C.C foundation

Each 209769 7063.69 216833.00

Page 43: Electrical CSR 12-13

6-4-4 Supplying, erecting, testing (by licencee), commissioning cubical comprising 11 kV H.T. metering, resin cast CTs, PTs, as per licencee's requirement, DO fuse set, AB switch 200 to 400A capacity duly interconnected with use of suitable insulators by maintening adequate clearences as per IS, complete housed in the encloser made up of MS structure and fiber glass 3 mm thick with gearbox & handle brought out for operating GOD, suitable door openings, locking arrangement etc complete duly tested by Licensee with necessary Test Certificates and erected on provided plinth/ C.C foundation

Each 403954 35816.73 439771.00

6-4-5 Supplying, erecting, testing (by licencee), commissioning cubical comprising 22 kV H.T. metering, resin cast CTs, PTs, as per licencee's requirement, DO fuse set, AB switch 200 to 400A capacity duly interconnected with use of suitable insulators by maintening adequate clearences as per IS, complete housed in the encloser made up of MS structure and fiber glass 3 mm thick with gearbox & handle brought out for operating GOD, suitable door openings, locking arrangement etc complete duly tested by Licensee with necessary Test Certificates and erected on provided plinth/ C.C foundation .

Each 548051 35816.73 583868.00

6.5 Accessories 6-5-1 Providing and erecting Selector Switch suitable for

Voltmeter/Ammeter for 3 phase A.C supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs.

Each 562 25.34 587.00

6-5-2 Providing and erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio with 15VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.

Each 736 25.34 761.00

6-5-3 Supplying and erecting bank of metalised polypropylene condensers (MPP) with the standard capacities of 2,3,5,7,10,12.5 and 15 kVAR units of P.F. correction for operation on 3 phase 50 cycles 400/440V. (+10%) with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee.

KVAR

344 25.34 369.00

6-5-4 Supplying and erecting bank of mixdielectric condensors with the standard capacities of 2,3,5,7,10,12.5 and 15 kVAR units of P.F. correction for operation on 3 phase 50 cycles 400/440V. (+10%) with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee.

KVAR

759 25.34 784.00

6-5-5 Supplying and erecting bank of All Polypropylene condensors (APP type) with the standard capacities of 2,3,5,7,10,12.5 and 15 kVAR units of P.F. correction for operation on 3 phase 50 cycles 400/440V. (+10%) with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee.

kVAR

568 25.34 593.00

6-5-6 Supplying and erecting set of 3 pilot lamps all Bakelite with colour glasses with miniature lamps 230 V/250V erected on provided CRCA box with panel type fuses and connected with PVC wires.

Each 645 25.34 670.00

6-5-7 Supplying & erecting LED type indicating pilot lamp with LED colours Red / Yellow / Green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.

Each 233 25.34 258.00

6-5-8 Supplying & erecting LED type indicating pilot lamp with LED colour BLUE, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.

Each 590 25.34 615.00

6-5-9 Providing and erecting all bakelite test terminal block with bakelite cover and sealing arrangements erected on provided panel board and connected by the leads of the instrument (This block is to be provided wherever L. T. M. D. meters and RkVAH meters are to be tested.)

Each 480 25.34 505.00

Note :- 1) Erection of MPP type Capacitors shall be avoided. 2) In new installation APP type capacitors shall invariably be used.

Chapter : 7 CABLES (CB) 7.1 LT Cables (Aluminum) (LT-AL)

7-1-1 Supplying , erecting & Terminating PVC armoured cable 2 core 2.5 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 101 10.56 112.00

7-1-2 Supplying , erecting & Terminating PVC armoured cable 2 core 4 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs,on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 104 10.56 115.00

Page 44: Electrical CSR 12-13

7-1-3 Supplying , erecting & TerminatingPVC armoured cable 2 core 6 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 124 10.56 135.00

7-1-4 Supplying , erecting & Terminating PVC armoured cable 2 core 10 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 133 10.56 144.00

7-1-5 Supplying , erecting & Terminating PVC armoured cable 3 core 2.5 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 111 10.56 122.00

7-1-6 Supplying & erecting PVC armoured cable 3 core 4 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 111 10.56 122.00

7-1-7 Supplying & erecting PVC armoured cable 3 core 6 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 140 10.56 151.00

7-1-8 Supplying , erecting & TerminatingPVC armoured cable 3 core 10 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 150 10.56 161.00

7-1-9 Supplying , erecting & Terminating PVC armoured cable 3 core 16 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 168 17.95 186.00

7-1-10 Supplying , erecting & Terminating PVC armoured cable 3 core 25 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 204 17.95 222.00

7-1-11 Supplying , erecting & Terminating PVC armoured cable 3 core 35 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 254 17.95 272.00

7-1-12 Supplying , erecting & Terminating PVC armoured cable 3 core 50 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 313 17.95 331.00

7-1-13 Supplying , erecting & Terminating PVC armoured cable 4 core 4 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 132 17.95 150.00

7-1-14 Supplying , erecting & Terminating PVC armoured cable 4 core 6 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 153 17.95 171.00

7-1-15 Supplying , erecting & Terminating PVC armoured cable 4 core 10 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 158 17.95 176.00

7-1-16 Supplying , erecting & Terminating PVC armoured cable 4 core 16 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 195 17.95 213.00

7-1-17 Supplying , erecting & Terminating PVC armoured cable 3 1/2 core 25 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 237 17.95 255.00

7-1-18 Supplying , erecting & Terminating PVC armoured cable 3 1/2 core 35 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 277 17.95 295.00

Page 45: Electrical CSR 12-13

7-1-19 Supplying , erecting & Terminating PVC armoured cable 3 1/2 core 50 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 367 29.56 397.00

7-1-20 Supplying , erecting & Terminating PVC armoured cable 3 1/2 core 70 sq mm aluminium conductor with continuous 8.35 sq mm (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 472 29.56 502.00

7-1-21 Supplying , erecting & Terminating PVC armoured cable 3 1/2 core 95 sq mm aluminium conductor with continuous 8.35 sq mm (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 573 29.56 603.00

7-1-22 Supplying , erecting & Terminating PVC armoured cable 4 core 25 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 257 29.56 287.00

7-1-23 Supplying , erecting & Terminating PVC armoured cable 4 core 35 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 312 29.56 342.00

7-1-24 Supplying , erecting & TerminatingPVC armoured cable 4 core 50 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 401 29.56 431.00

7-1-25 Supplying , erecting & TerminatingPVC armoured cable 4 core 70 sq mm aluminium conductor with continuous 8.35 sq mm (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 519 29.56 549.00

7-1-26 Supplying , erecting & Terminating PVC armoured cable 4 core 95 sq mm aluminium conductor with continuous 8.35 sq mm (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe asper specification no. CB-LT/AL

Mtr. 637 29.56 667.00

7-1-27 Supplying , erecting & Terminating PVC armoured cable 3 1/2 core 120 sq mm aluminium conductor with continuous 12.97 sq mm (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 717 33.78 751.00

7-1-28 Supplying , erecting & Terminating PVC armoured cable 3-1/2 core 150 sq mm aluminium conductor with continuous 12.97 sq mm (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 831 52.79 884.00

7-1-29 Supplying , erecting & Terminating PVC armoured cable 1100 V. 3-1/2 core 185 sq mm aluminium conductor with continuous 12.97 sq mm (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 1025 52.79 1078.00

7-1-30 Supplying , erecting & Terminating PVC armoured cable 3-1/2 core 240 sq mm aluminium conductor with continuous 12.97 sq mm (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 1308 78.12 1386.00

7-1-31 Supplying , erecting & Terminating PVC armoured cable 3-1/2 core 300 sq mm aluminium conductor with continuous 12.97 sq mm (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 1600 78.12 1678.00

7-1-32 Supplying , erecting & Terminating PVC armoured cable 3-1/2 core 400 sq mm aluminium conductor with continuous 12.97 sq mm (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

Mtr. 2017 78.12 2095.00

7-1-33 Re-erecting PVC armoured cable 2 to 4 Core up to 50 sq mm on wall with necessary material & G.I. earth wire in an approved manner.

Mtr. 22 10.56 33.00

Note :- 1) Add Rs. 3/- per meter for erection of cables on stone wall. 2) Rate of all cables includes cost of lugs, glands, etc. required for erection and connection of cable. 3) For all type of cables instead of reading supplying and erecting read as a supplying, erecting and terminating.

Page 46: Electrical CSR 12-13

7.2 LT Cables (Copper) (LT-CU) 7-2-1 Supplying , erecting & Terminating PVC armoured cable 2 core 2.5 sq mm copper

conductor continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

Mtr. 132 10.56 143.00

7-2-2 Supplying , erecting & Terminating PVC armoured cable 2 core 4 sq mm copper conductor continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

Mtr. 166 10.56 177.00

7-2-3 Supplying , erecting & Terminating PVC armoured cable 2 core 6 sq mm copper conductor continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

Mtr. 213 10.56 224.00

7-2-4 Supplying , erecting & Terminating PVC armoured cable 2 core 10 sq mm copper conductor continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

Mtr. 314 10.56 325.00

7-2-5 Supplying , erecting & Terminating PVC armoured cable 3 core 2.5 sq mm copper conductor continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

Mtr. 162 10.56 173.00

7-2-6 Supplying , erecting & Terminating PVC armoured cable 3 core 4 sq mm copper conductor continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

Mtr. 207 10.56 218.00

7-2-7 Supplying , erecting & TerminatingPVC armoured cable 3 core 6 sq mm copper conductor continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

Mtr. 274 10.56 285.00

7-2-8 Supplying , erecting & Terminating PVC armoured cable 3 core 10 sq mm copper conductor continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

Mtr. 414 10.56 425.00

7-2-9 Supplying , erecting & Terminating PVC armoured cable 4 core 4 sq mm copper conductor continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

Mtr. 252 17.95 270.00

7-2-10 Supplying , erecting & Terminating PVC armoured cable 4 core 6 sq mm copper conductor continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

Mtr. 340 17.95 358.00

7-2-11 Supplying , erecting & Terminating PVC armoured cable 4 core 10 sq mm copper conductor continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

Mtr. 502 17.95 520.00

7-2-12 Supplying , erecting & Terminating PVC armoured cable 4 core 16 sq mm copper conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

Mtr. 725 17.95 743.00

7-2-13 Supplying , erecting & Terminating PVC armoured cable 4 core 25 sq mm copper conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

Mtr. 1190 17.95 1208.00

7-2-14 (New)

Supplying , erecting & Terminating PVC armoured cable 4 core 35 sq mm copper conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

Mtr. 1418 17.95 1436.00

Page 47: Electrical CSR 12-13

7-2-15 (New)

Supplying , erecting & Terminating PVC armoured cable 4 core 50 sq mm copper conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

Mtr. 1989 17.95 2007.00

Note :- 1) Add Rs. 3/- per meter for erection of cables on stone wall. 2) Rate of all cables includes cost of lugs, glands, etc. required for erection and connection of cable. 3) For all type of cables instead of reading supplying and erecting read as a supplying, erecting and terminating.

7.3 HT Cables (HT) 7-3-1 Supplying , erecting & Terminating 3 x 70 sq mm 11 kV, XLPE(E) armoured cable

on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification No. CB-HT

Mtr. 938 30.62 969.00

7-3-2 Supplying , erecting & Terminating 3 x 95 sq mm 11 kV, XLPE(E) armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification No. CB-HT

Mtr. 1105 30.62 1136.00

7-3-3 Supplying , erecting & Terminating 3 x 120 sq mm 11 kV, XLPE(E) armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification no. CB-HT

Mtr. 1254 30.62 1285.00

7-3-4 Supplying , erecting & Terminating 3 x 70 sq mm 22 kV, XLPE(E) armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification no. CB-HT

Mtr. 1436 30.62 1467.00

7-3-5 Supplying , erecting & Terminating 3 x 95 sq mm 22 kV, XLPE(E) armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification No. CB-HT

Mtr. 1474 30.62 1505.00

7-3-6 Supplying , erecting & Terminating 3 x 120 sq mm 22 kV, XLPE(E) armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification No. CB-HT

Mtr. 1637 30.62 1668.00

7-3-7 Supplying , erecting & Terminating 3 x 70 sq mm 33 kV, XLPE(E) armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification No. CB-HT

Mtr. 1534 30.62 1565.00

7-3-8 Supplying , erecting & Terminating 3 x 95 sq mm 33 kV, XLPE(E) armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification No. CB-HT

Mtr. 1977 30.62 2008.00

7-3-9 Supplying , erecting & Terminating 3 x 120 sq mm 33 kV, XLPE(E) armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification No. CB-HT

Mtr. 2124 30.62 2155.00

7-3-10 Supplying , erecting & Terminating 3 x 150 sq mm 11 kV, XLPE(E) armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification No. CB-HT

Mtr. 1418 40.12 1458.00

7-3-11 Supplying , erecting & Terminating 3 x 185 sq.mm 11 kV, XLPE(E) armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification No. CB-HT

Mtr. 1638 40.12 1678.00

7-3-12 Supplying , erecting & Terminating 3 x 240 sq mm 11 kV, XLPE(E) armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification No. CB-HT

Mtr. 2009 40.12 2049.00

7-3-13 Supplying , erecting & Terminating 3 x 300 sq mm 11 kV, XLPE(E) armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification No. CB-HT

Mtr. 2044 40.12 2084.00

7-3-14 Supplying , erecting & Terminating 3 x 400 sq mm 11 kV, XLPE(E) armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification No. CB-HT

Mtr. 2779 40.12 2819.00

Note :- 1) For all type of cables instead of reading supplying and erecting read as a supplying, erecting and terminating.

7.4 Cable Joints & End Termination Kits Cable Joints & End Termination Kits (LT Cables) (JT/LT)

Page 48: Electrical CSR 12-13

7-4-1 Providing & erecting epoxy straight through joint outdoor/indoor for LT PVC armoured cable 2.5 to 16 sq mm. cable, with necessary material as per specification No. CB-JT/LT

Each 547 157.3 704.00

7-4-2 Providing & erecting epoxy straight through joint outdoor/indoor for LT PVC armoured cable 25 to 50 sq mm. cable, with necessary material as per specification No. CB-JT/LT

Each 851 157.3 1008.00

7-4-3 Providing & erecting epoxy straight through joint outdoor/indoor for LT PVC armoured cable 70 to 95 sq mm cable, with necessary material as per specification No. CB-JT/LT

Each 1590 245.98 1836.00

7-4-4 Providing & erecting epoxy straight through joint outdoor/indoor for LT PVC armoured cable 120 to 185 sq.mm. cable, with necessary material as per specification No. CB-JT/LT

Each 1300 350.49 1650.00

7-4-5 Providing & erecting epoxy straight through joint outdoor/indoor for LT PVC armoured cable 240 sq.mm. cable, with necessary material as per specification No. CB-JT/LT

Each 2175 350.49 2525.00

7-4-6 Providing & erecting epoxy straight through joint outdoor/indoor for LT PVC armoured cable 300 sq.mm. cable, with necessary material as per specification No. CB-JT/LT

Each 2084 401.17 2485.00

7-4-7 Providing & erecting epoxy straight through joint outdoor/indoor for LT PVC armoured cable 400 sq.mm. cable, with necessary material as per specification No. CB-JT/LT

Each 2911 488.79 3400.00

7-4-8 Providing & erecting epoxy outdoor/indoor end termination kit for LT PVC armoured cable 2.5 to 16 sq.mm. cable, with necessary material as per specification No. CB-JT/LT

Each 171 157.3 328.00

7-4-9 Providing & erecting epoxy outdoor/indoor end termination kit for LT PVC armoured cable 25 to 50 sq.mm. cable, with necessary material as per specification No. CB-JT/LT

Each 226 157.3 383.00

7-4-10 Providing & erecting epoxy outdoor/indoor end termination kit for LT PVC armoured cable 70 to 120 sq.mm. cable, with necessary material as per specification No. CB-JT/LT

Each 269 245.98 515.00

7-4-11 Providing & erecting epoxy outdoor/indoor end termination kit for LT PVC armoured cable 150 to 185 sq.mm. cable, with necessary material as per specification No. CB-JT/LT

Each 386 350.49 736.00

7-4-12 Providing & erecting epoxy outdoor/indoor end termination kit for LT PVC armoured cable 225 to 300 Sq.mm. cable, with necessary material as per specification no. CB-JT/LT

Each 463 350.49 813.00

7-4-13 Providing & erecting epoxy outdoor/indoor end termination kit for LT PVC armoured cable 400 sq.mm. cable, with necessary material as per specification No. CB-JT/LT

Each 596 488.79 1085.00

7.5 Cable Joints & End Termination Kits (HT Cables) (JT/HT) 7-5-1 Providing and erecting Heat shrinkable indoor termination kit for 11 kV (

E ) XLPE HT cable 3x70 to 120 sq. mm. with necessary material as per specification No. CB-JT/HT

Each 5128 702.04 5830.00

7-5-2 Providing and erecting Heat shrinkable indoor termination kit for 22 kV ( E ) XLPE HT cable 3x70 to 120 sq. mm. with necessary material as per specification No. CB-JT/HT

Each 6991 702.04 7693.00

7-5-3 Providing and erecting Heat shrinkable indoor termination kit for 33 kV ( E ) XLPE HT cable 3x70 to 95 sq. mm. with necessary material as per specification No. CB-JT/HT

Each 10930 702.04 11632.00

7-5-4 Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x150 to 185 sq. mm. with necessary material as per specification No. CB-JT/HT

Each 5382 702.04 6084.00

7-5-5 Providing and erecting Heat shrinkable indoor termination kit for 22 kV ( E ) XLPE HT cable 3x150 to 185 sq. mm. with necessary material as per specification No. CB-JT/HT

Each 8532 702.04 9234.00

7-5-6 Providing and erecting Heat shrinkable indoor termination kit for 33 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification No. CB-JT/HT

Each 12332 702.04 13034.00

7-5-7 Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 400sq. mm. with necessary material as per specification No. CB-JT/HT

Each 7191 702.04 7893.00

7-5-8 Providing and erecting Heat shrinkable indoor termination kit for 22 kV ( E ) XLPE HT cable 3x240 to 400 sq. mm. with necessary material as per specification No. CB-JT/HT

Each 10712 702.04 11414.00

7-5-9 Providing and erecting Heat shrinkable indoor termination kit for 33 kV ( E ) XLPE HT cable 3x240 to 400 sq. mm. with necessary material as per specification No. CB-JT/HT

Each 16806 702.04 17508.00

7-5-10 Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3x70 to 120 sq mm with necessary material as per specification No. CB-JT/HT

Each 7292 752.71 8045.00

7-5-11 Providing and erecting Heat shrinkable out door termination kit for 22 kV ( E ) XLPE HT cable 3x70 to 120 sq mm cable with necessary material as per specification No. CB-JT/HT

Each 11627 752.71 12380.00

Page 49: Electrical CSR 12-13

7-5-12 Providing and erecting Heat shrinkable out door termination kit for 33 kV ( E ) XLPE HT cable 3x70 to 95 sq. mm. with necessary material as per specification No. CB-JT/HT

Each 16038 752.71 16791.00

7-5-13 Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E ) XLPE HT cable 3x150 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT

Each 7734 752.71 8487.00

7-5-14 Providing and erecting Heat shrinkable outdoor termination kit for 22 kV ( E ) XLPE HT cable 3x150 to 185 sq. mm. with necessary material as per specification No. CB-JT/HT

Each 11953 752.71 12706.00

7-5-15 Providing and erecting Heat shrinkable outdoor termination kit for 33 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification No. CB-JT/HT

Each 16806 752.71 17559.00

7-5-16 Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 400 sq. mm. with necessary material as per specification No. CB-JT/HT

Each 9354 752.71 10107.00

7-5-17 Providing and erecting Heat shrinkable outdoor termination kit for 22 kV ( E ) XLPE HT cable 3x240 to 400 sq. mm. with necessary material as per specification No. CB-JT/HT

Each 15558 752.71 16311.00

7-5-18 Providing and erecting Heat shrinkable outdoor termination kit for 33 kV ( E ) XLPE HT cable 3x240 to 400 sq. mm. with necessary material as per specification No. CB-JT/HT

Each 19906 752.71 20659.00

7-5-19 Providing and erecting Heat shrinkable Straight through joint kit for 11 kV ( E ) XLPE HT cable 3x70 to 120 sq. mm. with necessary material as per specification No. CB-JT/HT

Each 17526 877.29 18403.00

7-5-20 Providing and erecting Heat shrinkable Straight through joint kit for 22 kV ( E ) XLPE HT cable 3x70 to 120 sq. mm with necessary material as per specification No. CB-JT/HT

Each 31413 877.29 32290.00

7-5-21 Providing and erecting Heat shrinkable Straight through joint kit for 33 kV ( E ) XLPE HT cable 3x70 to 95 sq mm with necessary material as per specification No. CB-JT/HT

Each 41467 877.29 42344.00

7-5-22 Providing and erecting Heat shrinkable Straight through joint kit for 11 kV ( E ) XLPE HT cable 3x150 to 240 sq. mm. with necessary material as per specification No. CB-JT/HT

Each 18791 877.29 19668.00

7-5-23 Providing and erecting Heat shrinkable Straight through joint kit for 22 kV ( E ) XLPE HT cable 3x150 to 240 sq. mm. with necessary material as per specification No. CB-JT/HT

Each 33241 877.29 34118.00

7-5-24 Providing and erecting Heat shrinkable Straight through joint kit for 33 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification No. CB-JT/HT

Each 51170 877.29 52047.00

7-5-25 Providing and erecting Heat shrinkable Straight through joint kit for 11 kV ( E ) XLPE HT cable 3x300 to 400 sq. mm. with necessary material as per specification No. CB-JT/HT

Each 21068 877.29 21945.00

7-5-26 Providing and erecting Heat shrinkable Straight through joint kit for 22 kV ( E ) XLPE HT cable 3x300 to 400 sq. mm with necessary material as per specification No. CB-JT/HT

Each 38989 877.29 39866.00

7-5-27 Providing and erecting Heat shrinkable Straight through joint kit for 33 kV ( E ) XLPE HT cable 3x300 to 400 sq mm with necessary material as per specification No. CB-JT/HT

Each 43461 877.29 44338.00

7.6 Cable Enclosures (CE) 7-6-1 Supplying & erecting G.I. pipe ‘A’ grade 25 mm dia. erected for

enclosing PVC armoured cable on wall/pole as per specification No. CW- PLB/GP, para 4.2.1 & 4.2.2 (Chapter 17.5)

Mtr. 114 9.5 124.00

7-6-2 Supplying & erecting G.I. pipe ‘A’ grade 40 mm dia. erected for enclosing PVC armoured cable on wall/pole as per specification No. CW- PLB/GP, para 4.2.1 & 4.2.2 (Chapter 17.5)

Mtr. 176 9.5 186.00

7-6-3 Supplying & erecting G.I. pipe ‘A’ grade 50 mm dia. erected for enclosing PVC armoured cable on wall/pole as per specification No. CW- PLB/GP, para 4.2.1 & 4.2.2 (Chapter 17.5)

Mtr. 217 14.78 232.00

7-6-4 Supplying & erecting G.I. pipe ‘A’ grade 75 mm dia. erected for enclosing PVC armoured cable on wall/pole as per specification No. CW- PLB/GP, para 4.2.1 & 4.2.2 (Chapter 17.5)

Mtr. 347 14.78 362.00

7-6-5 Supplying & laying (including excavation) 15 cm dia RCC Hume pipe with coupling collar of standard thickness at required depth up to 90 cm below road / ground surface, for enclosing provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).

Mtr. 265 220.64 486.00

7-6-6 Supplying & laying (including excavation) 15 cm dia half round RCC Hume pipe of standard thickness at required depth up to 90 cms. below road / ground surface, for enclosing provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).

Mtr. 160 133.02 293.00

7-6-7 Supplying & laying (including excavation) 25 cm dia RCC Hume pipe of standard thickness at required depth up to 90 cms. below road / ground surface, for covering provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).

Mtr. 360 220.64 581.00

Page 50: Electrical CSR 12-13

7-6-8 Supplying & laying (including excavation) 25 cm Dia half round RCC Hume pipe of standard thickness at required depth up to 90 cms. below road / ground surface, for enclosing provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).

Mtr. 216 133.02 349.00

7-6-9 Providing & laying 50 mm dia G.I. pipe ‘B’ grade for enclosing cable below ground/road surface, complete as per specification No. CW-PLB/GP, para 4.2.3 (Chapter 17.5)

Mtr. 259 145.69 405.00

7-6-10 Providing & laying 75 mm dia G.I. pipe ‘B’ grade for enclosing cable below ground/road surface, complete as per specification No. CW-PLB/GP, para 4.2.3 (Chapter 17.5)

Mtr. 410 145.69 556.00

7-6-11 Supplying and laying (including excavation) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

Mtr. 61 145.69 207.00

7-6-12 Supplying and laying (including excavation) 77 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

Mtr. 70 145.69 216.00

7-6-13 Supplying and laying (including excavation) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

Mtr. 114 145.69 260.00

7-6-14 Supplying and laying (including excavation) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

Mtr. 156 145.69 302.00

7-6-15 Supplying and laying (including excavation) 146 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

Mtr. 210 145.69 356.00

7-6-16 Supplying and laying (including excavation) 160 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

Mtr. 229 145.69 375.00

7-6-17 Supplying and laying (including excavation) 175 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

Mtr. 262 145.69 408.00

7-6-18 Supplying and laying (including excavation) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

Mtr. 442 145.69 588.00

Note :- 1)For erection of G I pipe on stone wall add Rs.3/- per meter to the overall rate. 2)All the GI pipes and DWC pipes shall be ISI marked. 3) DWC pipe shall be preferably used for the length where possibility of damaging of cable is more. If DWC pipe for length of more than 25m is to be used depending on environmental condition , approval should be taken from concerned Superintending Engineer 4) For running the cable across the field / along the road , it should be covered by half round Hume Pipe only.

7.7 Cable Glands (GL) 7-7-1 Supplying & erecting Siemens type brass cable glands for 2 to 4 core 2.5

sq mm /2 to 4 core 4 sq mm /2 core 6 sq mm for PVC armoured cable as per specification No. CB-GL

Each 20 7.39 27.00

7-7-2 Supplying & erecting Siemens type brass cable glands for 3 to 4 core 6 sq mm /2 to 4 core 10 sq mm for PVC armoured cable as per specification No. CB-GL

Each 27 14.78 42.00

7-7-3 Supplying & erecting Siemens type brass cable glands for 3 to 4 core 16 sq mm /3 to 4 core 25 sq mm /3 core 35 sq mm for PVC armoured cable as per specification No. CB-GL

Each 48 22.17 70.00

7-7-4 Supplying & erecting Siemens type brass cable glands for 4 core 35 Sq.mm./3 core 50 Sq.mm. for PVC armoured cable as per specification no. CB-GL

Each 59 22.17 81.00

7-7-5 Supplying & erecting Siemens type brass cable glands for 4 core 50 sq mm for PVC armoured cable as per specification No. CB-GL

Each 67 30.62 98.00

7-7-6 Supplying & erecting Siemens type brass cable glands for 3 1/2 core 70 sq mm for PVC armoured cable as per specification No. CB-GL

Each 83 30.62 114.00

7-7-7 Supplying & erecting Siemens type brass cable glands for 3 1/2 core 95 sq mm for PVC armoured cable as per specification No. CB-GL

Each 83 30.62 114.00

7-7-8 Supplying & erecting Siemens type brass cable glands for 3 1/2 core 120 sq mm for PVC armoured cable as per specification No. CB-GL

Each 100 30.62 131.00

7-7-9 Supplying & erecting Siemens type brass cable glands for 3 1/2 core 150 sq mm for PVC armoured cablen as per specification No. CB-GL

Each 127 30.62 158.00

7-7-10 Supplying & erecting Siemens type brass cable glands for 3 1/2 core 185 sq mm for PVC armoured cable as per specification No. CB-GL

Each 167 33.78 201.00

7-7-11 Supplying & erecting Siemens type brass cable glands for 3 1/2 core 240 sq mm for PVC armoured cable as per specification No. CB-GL

Each 215 33.78 249.00

7-7-12 Supplying & erecting Siemens type brass cable glands for 3 1/2 core 300 sq mm for PVC armoured cable as per specification No. CB-GL

Each 267 40.12 307.00

7-7-13 Supplying & erecting Siemens type brass cable glands for 3 1/2 core 400 sq mm for PVC armoured cable as per specification No. CB-GL

Each 303 49.62 353.00

Note :- 1) For use of Flange type glands increase overall rate by 50%.

Page 51: Electrical CSR 12-13

2) Glands are to be provided at time of joints/repairs.

7.8 Street Light Boxes & Cable Indicators (SB) 7-8-1 Supplying & erecting cast iron cable indicator plate buried along with

route of cable for PVC / XLPE armoured cable as per specification No. CB- CIP

Each 174 14.78 189.00

7-8-2 Supplying & erecting water tight terminal box of 1.6 mm (16 gauge) CRCA sheet of size 200 x 150 x 150 mm. complete on pole as per specification No. CB-SB

Each 407 24.28 431.00

7-8-3 Supplying & erecting water tight terminal box of 1.6 mm (16 gauge) CRCA sheet of size 300 x 200 x 150 mm complete on pole as per specification No. CB-SB

Each 657 24.28 681.00

7-8-4 Supplying & erecting water tight terminal box of 1.6 mm (16 gauge) CRCA sheet of size 150 x 100 x 100 mm complete on pole as per specification No. CB-SB

Each 263 24.28 287.00

7-8-5 Supplying & erecting water tight terminal box of cast iron of size 200 x 150 x 150 mm complete on pole as per specification No. CB-SB

Each 595 24.28 619.00

7-8-6 Supplying & erecting water tight terminal box of cast iron of size 300 x 200 x 150 mm complete on pole as per specification No. CB-SB

Each 717 24.28 741.00

7-8-7 Supplying & erecting water tight terminal box of cast iron of size 150 x 100 x 100 mm complete on pole as per specification No. CB-SB

Each 501 24.28 525.00

7-8-8 Supplying & erecting FRP box of size 300mm x 200mm x 125 mm., 2.7 mm thick complete on pole as per specification No. CB-SB

Each 576 24.28 600.00

7-8-9 Supplying & erecting FRP box of size 250mm x 200mm x 100 mm., 2.7 mm thick complete on pole as per specification No. CB-SB

Each 496 24.28 520.00

7-8-10 Supplying & erecting FRP box of size 150mm x 125mm x 100 mm., 2.7 mm thick complete on pole as per specification No. CB-SB

Each 343 24.28 367.00

7.9 Cable Lugs (Copper) (CL/CU) 7-9-1 Supplying & erecting crimping type copper lugs for cable upto 16 sq mm

complete as per specification No. CB-CL/CUEach 9 5.28 14.00

7-9-2 Supplying & erecting crimping type copper lugs for cable 25 sq mm complete as per specification No. CB-CL/CU

Each 23 5.28 28.00

7-9-3 Supplying & erecting crimping type copper lugs for cable 35 sq mm complete asper specification No. CB-CL/CU

Each 25 6.33 31.00

7-9-4 Supplying & erecting crimping type copper lugs for cable 50 sq mm complete as per specification No. CB-CL/CU

Each 32 6.33 38.00

7-9-5 Supplying & erecting crimping type copper lugs for cable 70 sq mm complete as per specification No. CB-CL/CU

Each 52 6.33 58.00

7-9-6 Supplying & erecting crimping type copper lugs for cable 95 sq mm complete as per specification No. CB-CL/CU

Each 65 7.39 72.00

7-9-7 Supplying & erecting crimping type copper lugs for cable 120 sq mm complete as per specification No. CB-CL/CU

Each 89 9.5 99.00

7-9-8 Supplying & erecting crimping type copper lugs for cable 150 sq mm complete as per specification No. CB-CL/CU

Each 119 14.78 134.00

7-9-9 Supplying & erecting crimping type copper lugs for cable 185 sq mm complete as per specification No. CB-CL/CU

Each 182 14.78 197.00

7-9-10 Supplying & erecting crimping type copper lugs for cable 240 sq mm complete as per specification No. CB-CL/CU

Each 265 14.78 280.00

7-9-11 Supplying & erecting crimping type copper lugs for cable 300 sq mm complete as per specification No. CB-CL/CU

Each 347 14.78 362.00

7-9-12 Supplying & erecting crimping type copper lugs for cable 400 sq mm complete as per specification No. CB-CL/CU

Each 500 19 519.00

7.10 Cable Lugs (Aluminium) (CL/AL) 7-10-1 Supplying & erecting crimping type aluminium lugs for cable upto 16 sq

mm complete as per specification No. CB-CL/ALEach 3 2.11 5.00

7-10-2 Supplying & erecting crimping type aluminium lugs for cable 25 sq mm complete as per specification No. CB-CL/AL

Each 5 2.11 7.00

7-10-3 Supplying & erecting crimping type aluminium lugs for cable 35 sq mm complete as per specification No. CB-CL/AL

Each 6 6.33 12.00

7-10-4 Supplying & erecting crimping type aluminium lugs for cable 50 sq mm complete as per specification No. CB-CL/AL

Each 9 6.33 15.00

7-10-5 Supplying & erecting crimping type aluminium lugs for cable 70 sq mm complete as per specification No. CB-CL/AL

Each 13 6.33 19.00

7-10-6 Supplying & erecting crimping type aluminium lugs for cable 95 sq mm complete as per specification No. CB-CL/AL

Each 15 6.33 21.00

7-10-7 Supplying & erecting crimping type aluminium lugs for cable 120 sq mm complete as per specification No. CB-CL/AL

Each 21 7.39 28.00

7-10-8 Supplying & erecting crimping type aluminium lugs for cable 150 sq mm complete as per specification No. CB-CL/AL

Each 27 8.45 35.00

7-10-9 Supplying & erecting crimping type aluminium lugs for cable 185 sq mm complete as per specification No. CB-CL/AL

Each 33 13.72 47.00

7-10-10 Supplying & erecting crimping type aluminium lugs for cable 240 sq mm complete as per specification No. CB-CL/AL

Each 57 13.72 71.00

Page 52: Electrical CSR 12-13

7-10-11 Supplying & erecting crimping type aluminium lugs for cable 300 sq mm complete as per specification No. CB-CL/AL

Each 80 23.23 103.00

7-10-12 Supplying & erecting crimping type aluminium lugs for cable 400 sq mm complete as per specification No. CB-CL/AL

Each 115 23.23 138.00

Note :- Lugs are to be provided at time of joints/repairs.

7.11 Dismantling 7-11-1 Dismantling the existing cables of all types & sizes Mtr. 0 20.06 20.00 7-11-2 Refilling the holes for dismantled cables with cement mortar & finishing

in an aproved manner etc. completeMtr. 15 20.06 35.00

7-11-3 Dismantling the existing underground cable without damaging it with glands, cable end box including refilling the trench up to ground level and making coils complete.

Mtr. 0 24.28 24.00

Note :- 1)The rates for item no 7.11.1 to 7.11.3 are for dismantling and handing over to section office inclusive of transportation upto 25 km, between site and section office. 2)Item No 7.11.3 shall be used only when the cost of dismantled cable is more than Rs. 23/- per meter.

Chapter : 8 OVER HEAD SYSTEMS (OH) 8.1 Steel Poles (OH-PL)

8-1-1 Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (5 + 1.75 + 1.75 mtr) length respectively and total 8.5 m long with pole cap, base plate in provided foundation.(weight 109 kg.) as per specification No. OH-PL/STP

Each 11063 401.17 11464.00

8-1-2 Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (5 + 2 + 2 m) length respectively and total 9m long with pole cap, base plate in provided foundation (weight 113 kg.) as per specification No. OH-PL/STP

Each 11468 399.05 11867.00

Note :- Above items shall be used only for street lighting. 8-1-3 Supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3

mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2 m ) length respectively and total 9 Mtr long -- do --. (weight 147 kg) as per specification No. OH-PL/STP

Each 14765 533.13 15298.00

Note :- These item shall be used only for L T O H line. 8-1-4 Supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3

mm dia with 4.5 x 4.5 x 3.65 mm. thickness (5 + 2.5 + 2.5 m) length respectively and total 10 m long -- do --.(weight 157/160 kg) as per specification No. OH-PL/STP

Each 12984 529.96 13514.00

8-1-5 Supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia. with 4.5 x4.5 x3.65 mm thickness (5.60 + 2.7 + 2.7 m) length total 11 m long -- do --. (weight 175 kq.) as per specification No. OH-PL/STP

Each 14208 693.59 14902.00

8-1-6 Supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia. with 5.4 x 4.5 x 3.65 mm. thickness (5.8 + 3.1 + 3.1 mtr) length total 12 m long -- do --. (weight 208 kg.) as per specification No. OH- PL/STP

Each 20742 945.91 21688.00

8-1-7 Supplying and erecting Rolled steel Joist (Girder) pole 150 x 80 mm./150 x75 mm. (14.9 kg /m) with provided base plate in provided foundation as per specification No. OH-PL/RSJ

Mtr. 822 98.18 920.00

8-1-8 Supplying and erecting Rolled steel Joist (Girder) pole 200 x 100 mm. (25.4 kg/m) with provided base plate in provided foundation as per specification No. OH-PL/RSJ

Mtr. 1356 146.74 1503.00

8-1-9 Supplying and erecting Rolled steel Joist (Girder) pole 175 x 90 mm (19.3 kg/m) with provided base plate in provided foundation as per specification No. OH-PL/RSJ

Mtr. 1046 146.74 1193.00

Note :- Pole as per Item no. 8-1-9 shall only be used as Intermediate Pole.

8-1-10 Supplying and erecting Rolled steel Joist (Girder) pole 100 x 116 mm (23 kg/m) with provided base plate in provided foundation as per specification No. OH-PL/RSJ

Mtr. 1234 146.74 1381.00

8-1-11 Supplying and erecting Rolled steel Joist (Girder) pole 125 x 75 mm (12.42 kg/m) with provided base plate in provided foundation as per specification No. OH-PL/RSJ

Mtr. 696 98.18 794.00

Note :- Pole as per Item no. 8-1-11 shall only be used as Intermediate Pole.

8-1-12 Supplying and erecting Rolled steel Joist (Girder) pole 152 x 152 mm (37kg/m) with provided base plate in provided foundation as per specification No. OH-PL/RSJ

Mtr. 1945 210.08 2155.00

8-1-13 Supplying and erecting Rail pole (29.76 kg/m) with provided base plate in provided foundation as per specification No. OH-PL/RLP

Mtr. 1577 163.63 1741.00

Page 53: Electrical CSR 12-13

Note :- As per contour of the site and position of different obstacles/layout the length of RSJ pole to be considered for each pole and the measurement sheet should be attached in estimate/bill. Necessary arrangement for earthing shall be provided, also the base plate should be taken separately for each pole

8-1-14 Supplying and erecting ISI mark G.I. pipe pole ‘B’ grade 75/80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification No. OH-PL/GIP

Each 3788 215.36 4003.00

8-1-15 Supplying and erecting M.S. pipe pole ‘B’ grade 75/80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification No. OH- PL/GIP

Each 3357 215.36 3572.00

8-1-16 Supplying and erecting steel tubular swaged type welded pole with upper portion hydraulically bent swan neck, 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.50 x 3.65 mm thickness (5 + 2 + 3 m) respectively (net vertical height 9 m.) total length 10 m long with base plate in provided foundation.(weight 156.75 kg) as per specification No. OH-PL/STP

Each 13453 636.59 14090.00

8-1-17 Supplying and erecting steel tubular swaged type welded pole with upper portion bent swan neck, 165.1 x 139.7 x 114.3 mm dia. with 4.5 x 4.5 x 3.65 mm thickness (5.6 + 2.7 + 2.7 m) respectively total 11 m long long with base plate in provided foundation.(weight 175 kg) as per specification No.OH-PL/STP

Each 14665 15481.84 30147.00

8.2 PSC / Spun / GRP Poles (OH-PSC/ SPN / GRP) PSC Poles

8-2-1 Supplying and erecting PSC rectangular pole of top 90 x 102 / 105 mm & bottom of 90 x 275 mm 8 m long (345 kg) complete erected in provided C. C. foundation & muffing (square/round) as per specification No. OH-PL/PSC

Each 1825 730.54 2556.00

8-2-2 Supplying and erecting PSC rectangular pole of top 105 x 115 mm & bottom of 105 x 315 mm 9 m long (510 kg complete erected in provided C. C. foundation & muffing (square/round) as per specification No. OH-PL/PSC

Each 2502 1066.26 3568.00

Spun Poles 8-2-3 Deleted Each 8-2-4 Deleted Each 8-2-5 Deleted Each 8-2-6 Deleted Each 8-2-7 Deleted Each

GRP Poles 8-2-8 Supplying and erecting glass reinforced polymer composit (GRP) with

high impact strength in square ( top and bottom dia 75 mm ) / conical ( top dia 76mm and bottom dia 143 mm) shape and thickness 6 mm having height 4 m designed to withstand wind load upto 180 km/ hr as per specification No.OH-PL/GRP

Each 11987 1066.26 13053.00

8-2-9 Supplying and erecting glass reinforced polymer composit (GRP) with high impact strength in conical ( top dia 76mm and bottom dia 176 mm) shape and thickness 6 mm having height 6 m designed to withstand wind load upto 180 km/ hr as per specification No.OH-PL/GRP

Each 16376 1066.26 17442.00

8-2-10 Supplying and erecting glass reinforced polymer composit (GRP) with high impact strength in conical (top dia 76mm and bottom dia 227 mm) shape and thickness 6 mm having height 9 m designed to withstand wind load upto 180 km/ hr as per specification No.OH-PL/GRP

Each 28164 1066.26 29230.00

8-2-11 Supplying and erecting glass reinforced polymer composit (GRP) with high impact strength in conical (top dia 76mm and bottom dia 260 mm) shape and thickness 6 mm having height 11 m designed to withstand wind load upto 180 km/ hr as per specification No.OH-PL/GRP

Each 45921 1066.26 46987.00

8-2-12 Supplying and erecting glass reinforced polymer composit (GRP) with high impact strength in conical (top dia 76mm and bottom dia 293 mm) shape and thickness 10 mm having height 13 m designed to withstand wind load upto 180 km/ hr as per specification No.OH-PL/GRP

Each 61689 1066.26 62755.00

8-2-13 Supplying & erecting single arm bracket (GRP) with length 1000 mm and 48 mm dia having height 280 mm suitable for conical / square GRP Poles. Bracket includes cap ,arms for fitting and connecting part in GRP moulded case and easy to insert on pole top and fitting with necessary hardware as per specification No.OH-PL/GRP

Each 6382 145.69 6528.00

8-2-14 Supplying & erecting double arm bracket (GRP) with length 1000 mm and 48 mm dia for each arm having height 280 mm suitable for conical / square GRP Poles. Bracket includes cap ,arms for fitting and connecting part in GRP moulded case and easy to insert on pole top and fitting with necessary hardware as per specification No.OH-PL/GRP

Each 9786 145.69 9932.00

8-2-15 Supplying & erecting internal junction box (small) GRP suitable for providing MCB / HRC Fuse for conical / square GRP Poles for pole upto 6 mtrs in height as per specification No.OH-PL/GRP

Each 2979 145.69 3125.00

8-2-16 Supplying & erecting internal junction box (big) GRP suitable for providing MCB / HRC Fuse for conical / square GRP Poles for pole above 6 mtrs in height as per specification No.OH-PL/GRP

Each 8679 145.69 8825.00

Page 54: Electrical CSR 12-13

8-2-17 Supplying & erecting base bracket (GRP) with necessary SS 304 hardware to hold the two compartments of GRP base brackets and 8 nos 16 mm long foundation nut bolts (EN-8) on provided foundation suitable for conical / square GRP poles. Bracket height is 750 mm and pitch circle dia 550 mm as per specification No.OH-PL/GRP

Each 10130 145.69 10276.00

Note :- GRP Poles shall be used only in highly corrosive and costal area

8.3 Hot Dipped Galvanized Poles & High Mast (HM) 8-3-1 Providing and erecting 12.5m High-Mast Pole weight 240 kg on provided

foundation as per specification No. OH-PL/HMSet. 46626 13137.13 59763.00

8-3-3 Supplying and erecting 12.5 m High Mast with lowering and raising motorized unit, with carriage assembly for 6 - 8 Luminaries and its control gear box, lighting stand and avaition light (excluding Luminaries) on provided foundation as per specification No. OH-PL/HM

Set. 178812 35947 214759.00

8-3-4 Supplying and erecting 16 m High Mast with lowering and raising motorized unit, with carriage assembly for 6 - 8 Luminaries and its control gear box, lighting stand and avaition light (excluding Luminaries) on provided foundation as per specification No. OH-PL/HM

Set. 219348 46505 265853.00

8-3-5 Supplying and erecting 20 m High Mast with lowering and raising motorized unit, with carriage assembly for 6 - 8 Luminaries and its control gear box, lighting stand and avaition light (excluding Luminaries) on provided foundation as per specification No. OH-PL/HM

Set. 269195 51783 320978.00

8-3-6 Deleted 8-3-7 Deleted

Sword type Brackets 8-3-8 (New)

Providing & erecting Sword type bracket with single arm, 1000 mm in length, with all hardware on provided pole, as per specification No. OH-PL/PSC

Each 1960 184.75 2145.00

8-3-9 (New)

Providing & erecting Sword type bracket with double arm, 1000 mm in length, with all hardware on provided pole, as per specification No. OH- PL/PSC

Each 3767 184.75 3952.00

Note :- 1) For bracket length of 1500 mm (Single/Double arm) increase overall rates by 20 %. 2) Above brackets are suitable for OCTAGONAL/CONICAL Poles from 3 to 12 m in length. Hot Dipped Galvanized OCTAGONAL Poles

8-3-10 (New)

Providing & erecting 3 m high galvanised OCTAGONAL pole with bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 4962 915.29 5877.00

8-3-11 (New)

Providing & erecting 4 m high galvanised OCTAGONAL pole with bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 6140 915.29 7055.00

8-3-12 (New)

Providing & erecting 5 m high galvanised OCTAGONAL pole with bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 7285 915.29 8200.00

8-3-13 (New)

Providing & erecting 6 m high galvanised OCTAGONAL pole with bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 8686 915.29 9601.00

8-3-14 (New)

Providing & erecting 7 m high galvanised OCTAGONAL pole with bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 9754 1372.41 11126.00

8-3-15 (New)

Providing & erecting 8 m high galvanised OCTAGONAL pole with bottom of 135 mm A/F, top 70 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 11468 1372.41 12840.00

8-3-16 (New)

Providing & erecting 9 m high galvanised OCTAGONAL pole with bottom of 155 mm A/F, top 70 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 13861 1524.43 15385.00

8-3-17 (New)

Providing & erecting 10 m high galvanised OCTAGONAL pole with bottom of 175 mm A/F, top 70 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 16641 1524.43 18165.00

8-3-18 (New)

Providing & erecting 11 m high galvanised OCTAGONAL pole with bottom of 210 mm A/F, top 90 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 22454 1829.53 24284.00

8-3-19 (New)

Providing & erecting 12 m high galvanised OCTAGONAL pole with bottom of 240 mm A/F, top 90 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 27318 1829.53 29148.00

Hot Dipped Galvanized CONICAL Poles

Page 55: Electrical CSR 12-13

8-3-20 (New)

Providing & erecting 3 m high galvanised CONICAL pole with bottom of 107 to 115 mm A/F, top 65 to 75 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 7585 915.29 8500.00

8-3-21 (New)

Providing & erecting 4 m high galvanised CONICAL pole with bottom of 118 to 130 mm A/F, top 65 to 75 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 9949 915.29 10864.00

8-3-22 (New)

Providing & erecting 5 m high galvanised CONICAL pole with bottom of 129 to 145 mm A/F, top 65 to 75 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 12642 915.29 13557.00

8-3-23 (New)

Providing & erecting 6 m high galvanised CONICAL pole with bottom of 140 to 160 mm A/F, top 65 to 75 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 15846 915.29 16761.00

8-3-24 (New)

Providing & erecting 7 m high galvanised CONICAL pole with bottom of 151 to 175 mm A/F, top 65 to 75 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 19213 1372.41 20585.00

8-3-25 (New)

Providing & erecting 8 m high galvanised CONICAL pole with bottom of 162 to 190 mm A/F, top 65 to 75 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 22467 1372.41 23839.00

8-3-26 (New)

Providing & erecting 9 m high galvanised CONICAL pole with bottom of 173 to 200 mm A/F, top 65 to 75 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 26515 1372.41 27887.00

8-3-27 (New)

Providing & erecting 10 m high galvanised CONICAL pole with bottom of 184 to 200 mm A/F, top 65 to 75 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 29484 1524.43 31008.00

8-3-28 (New)

Providing & erecting 11 m high galvanised CONICAL pole with bottom of 206 to 245 mm A/F, top 70 to 85 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 35939 1676.45 37615.00

8-3-29 (New)

Providing & erecting 12 m high galvanised CONICAL pole with bottom of 228 to 260 mm A/F, top 80 to 96 mm A/F on provided foundation as per specification No. OH-PL/PSC

Each 42172 1829.53 44002.00

8.4 Brackets (BKT) 8-4-1 Supplying and erecting MS pole bracket, fabricated from angle iron

50x50x6 mm. and 550 mm long for vertical guarding for 2 insulators, complete as per specification No. OH-PL/BKT

Each 278 59.12 337.00

8-4-2 Supplying and erecting M.S. pole bracket, fabricated from angle iron 50x50x6 mm and 1100 mm long for horizontal guarding for 4 insulators, complete as per specification No. OH-PL/BKT

Each 479 59.12 538.00

8-4-3 Supplying and erecting MS pole bracket, fabricated from ISMC Channel 75x40x 6.8 mm and 550 mm long for vertical guarding for 4 insulators,complete as per specification No. OH-PL/BKT

Each 350 59.12 409.00

8-4-4 Supplying and erecting MS pole bracket, fabricated from ISMC Channel 75x40x 6.8 mm and 1100 mm long for vertical guarding for 5 insulators, complete as per specification No. OH-PL/BKT

Each 672 59.12 731.00

8-4-5 Supplying and erecting MS pole bracket fabricated from angle iron 65x65x6 mm and 550 mm long for 2 insulators complete as per specification No

Each 280 59.12 339.00

8-4-6 Supplying and erecting M.S pole bracket fabricated from angle iron 65x65x6 mm and 1100 mm long for 4 insulators complete as per specification No

Each 448 59.12 507.00

8-4-7 Supplying and erecting pole bracket, fabricated from ISMC channel, 75x40x6.8 mm channel 550mm long for 2 insulators, complete as per specification No.OH-PL/BKT

Each 347 59.12 406.00

8-4-8 Supplying and erecting pole bracket, fabricated from ISMC channel, 75x40x6.8 mm channel 1100mm long for 4 insulators, complete as per specification No.OH-PL/BKT

Each 582 59.12 641.00

8-4-9 Supplying and erecting pole bracket, fabricated from ISMC channel, 75x40x6.8 mm channel, 550 mm long for two insulators and welded with extension channel pieces of same size 300 mm. in length, complete as per specification No. OH-PL/BKT

Each 605 59.12 664.00

8-4-10 Supplying and erecting pole bracket, fabricated from ISMC channel, 75x40x6.8 mm channel, 1100 mm long for 4 insulators and welded with extension channel pieces of same size 300 mm. in length, complete as per specification No. OH-PL/BKT

Each 871 59.12 930.00

8-4-11 Supplying and erecting 100 x 50 mm with 4.7 mm thick web and 7.5 mm thick flange channel iron cross arm for 2.4 mtr. DP, complete as per specification No. OH-PL/BKT

Each 1664 122.46 1786.00

Note :- For distance exceeding 2.4 m between two pole structure add Rs. 840/- per meter for extra channel length.

Page 56: Electrical CSR 12-13

8-4-12 Supplying and erecting Vee cross arm for erecting Insulators with channel length of 45mm for base of insulator & vertical member of suitable length to maintain clearance of 1200 mm horizontally between two insulators with angle of 60 degree to horizontal and the total vertical height of V cross arm as 460mm, welded with MS flat of 80x10mm at centre of cross arm & MS clamp of 80x10 mm at bottom with clamps,nut bolts,washers complete as per specification No. OH-PL/VCA

Each 1029 122.46 1151.00

8-4-13 Supplying and erecting Vee cross arm for erecting Insulators with channel length of 45mm for base of insulator & vertical member of suitable length to maintain clearance of 1530 mm horizontally between two insulators with angle of 60 degree to horizontal and the total vertical height of V cross arm as 460mm, welded with MS flat of 80x10mm at centre of cross arm & MS clamp of 80x10 mm at bottom with clamps,nut bolts,washers complete as per specification No. OH-PL/VCA

Each 1608 122.46 1730.00

8-4-14 Supplying and erecting 75x40 mm with 4.4 mm thick web and 7.3 mm thick flange channel with clamp suitable for erection of 11/22 kV pin insulators complete as per specification No. OH-PL/VCA

Each 417 59.12 476.00

8-4-15 Supplying and erecting bracket for guarding, made from channel iron 1600 mm in length and 75x40 mm. with 4.4 mm. thick web and 7.3 mm thick flange erected on pole complete as per specification no. OH-PL/VCA

Each 804 59.12 863.00

8-4-16 Supplying and erecting bracket for guarding, made from channel iron 1600 mm in length and 65 x 65 x 6mm thick web and 7.3 mm thick flange erected on pole as per specification no. OH-PL/VCA

Each 586 69.68 656.00

Note :- All the brackets, cross arms are included with clamps, washers and nut bolts

8.5 Conductors (CON) 8-5-1 Supplying and erecting all aluminium stranded conductors 7/1.96 mm

complete.(Rose) (58 kg/km) as per specification No. OH-CON/AACKm. 15883 1160.21 17043.00

8-5-2 Supplying and erecting all aluminium stranded conductors 7/2.21 mm.complete. (Gnat) (73.77kg/km) as per specification No. OH-CON/AAC

Km. 20264 1160.21 21424.00

8-5-3 Supplying and erecting all aluminium stranded conductors 7/2.48 mm.complete. (lris) (91.8 kg/km) as per specification no. OH-CON/AAC

Km. 25193 1160.21 26353.00

8-5-4 Supplying and erecting all aluminium stranded conductors 7/2.78 mm.complete. (Pansy) (115.8 kg/km) as per specification No. OH- CON/AAC

Km. 31778 1666.95 33445.00

8-5-5 Supplying and erecting all aluminium stranded conductors 7/3.10 mm. complete. (Ant.) (145.0 kg/km) as per specification No. OH-CON/AAC

Km. 39707 1666.95 41374.00

8-5-6 Supplying and erecting ACSR conductor of size 6/1-2.11 mm. complete. (squirrel) (85kg/km) as per specification No. OH-CON/ACSR

Km. 20029 1666.95 21696.00

8-5-7 Supplying and erecting ACSR conductor of size 6/1-2.59 mm.complete. (Weasel) (127.7 kg/km) as per specification No. OH-CON/ACSR

Km. 30161 1374.52 31536.00

8-5-8 Supplying and erecting ACSR conductor of size 6/1-3.60 mm.complete. (Ferret) (171.3 kg/km) as per specification No. OH-CON/ACSR

Km. 40528 1812.64 42341.00

8-5-9 Supplying and erecting ACSR conductor of size 6/1-3.66 mm.complete.(Mink) (255 kg/km) as per specification No. OH-CON/ACSR

Km. 60086 1812.64 61899.00

8-5-10 Supplying and erecting ACSR conductor of size - 6/1-4.09 mm (Raccon) complete. (318.00 kg/km) as per specification No. OH-CON/ACSR

Km. 74930 2146.24 77076.00

8-5-11 Supplying and erecting ACSR conductor of size - 6/1-4.72 mm (Dog) complete. (394.00 kg/km) as per specification No. OH-CON/ACSR

Km. 92838 2549.52 95388.00

8-5-12 Supplying and erecting hard drawn G.I. wire 8 SWG complete erected for overhead line with proper size of G.I. wire for binding with jumpering etc.

Km. 9035 557.41 9592.00

8.6 Insulators (INS) 8-6-1 Supplying and erecting pin type LT medium insulator 100 mm x 62

mm dia. with suitable G.l. spindle, nut, bolts complete erected.Each 48 15.84 64.00

8-6-2 Supplying and erecting porcelain shackle type LT medium insulator 75x115 mm dia. with G.l. strips, nuts and bolts, complete.

Each 75 15.84 91.00

8-6-3 Supplying and erecting porcelain shackle type LT medium insulator 50 x 89 mm dia. with G.l. strips, nuts and bolts, complete.

Each 68 15.84 84.00

8-6-4 Supplying and erecting aluminium bobbin with G.l. strip, nuts complete. Each 54 15.84 70.00 8-6-5 Providing and fixing earthing stud with necessary materials. Each 16 7.39 23.00 8-6-6 Supplying and erecting porcelain disc type insulator suitable for 11kV

line, complete as per specification No. OH-INS/DIEach 1086 215.36 1301.00

8-6-7 Supplying and erecting porcelain disc type insulator suitable for 22kV line, complete as per specification No. OH-INS/DI

Each 1764 215.36 1979.00

8-6-8 Supplying and erecting porcelain disc type insulator suitable for 33 kV line complete as per specification No. OH-INS/DI

Each 2443 215.36 2658.00

8-6-9 Supplying and erecting porcelain pin type insulator suitable for 11kV line, complete as per specification No. OH-INS/PN

Each 247 74.95 322.00

8-6-10 Supplying and erecting porcelain pin type insulator suitable for 22kV line, complete as per specification No. OH-INS/PN

Each 814 74.95 889.00

8-6-11 Supplying and erecting porcelain pin type insulator suitable for 33kV line, complete as per specification No. OH-INS/PN

Each 1036 74.95 1111.00

Page 57: Electrical CSR 12-13

8-6-12 Supplying and erecting porcelain post type insulator suitable for 11kV line, complete as per specification No. OH-INS/PST

Each 766 74.95 841.00

8-6-13 Supplying and erecting porcelain post type insulator suitable for 22kV line,complete as per specification No. OH-INS/PST

Each 1480 74.95 1555.00

8-6-14 Supplying and erecting porcelain post type insulator suitable for 33kV line, complete as per specification No. OH-INS/PST

Each 2196 74.95 2271.00

8-6-15 Supplying and erecting Distribution class, 11 kV thyrite type lightening arrester, on provided cross arm as per specification No. OH-INS/LA

Each 2961 155.19 3116.00

8-6-16 Supplying and erecting Distribution class, 22 kV thyrite type lightening arresters, on provided cross arm as per specification No. OH-INS/LA

Each 5922 155.19 6077.00

8.7 Accessories 8-7-1 Supplying and erecting G.l. stay set for poles, including loop insulators

at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.l. stay wire 7/10 SWG, G.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation.

Each 1227 172.08 1399.00

8-7-2 Supplying and erecting G.l. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.l. stay wire 7/8 SWG, G.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation.

Each 1474 172.08 1646.00

8-7-3 Supplying and erecting G.I. fly stay set for pole including straining screw, G.l. stay wire, 7/10 SWG (for to 15mtr. long) with pole clamp, made of 50 x 6 mm MS flat, complete erected on provided RSJ pole. (Add. Rs. 25/- per m for extra length beyond 15 m)

Each 1110 257.59 1368.00

8-7-4 Supplying and erecting G.l. self stay set for pole, including anchor plate 300x 300 x 6 mm. straining screw, loop-insulator, G.l. stay wire 7/10 SWG, G.l. stay rod 20 mm x 1.8 m long, erected with pole clamps along with angle iron bracket of 50 x 50 x 6 mm and one meter long fixed to pole at suitable height with suitable MS clamps duly erected in provided C.C. foundations.

Each 1139 172.08 1311.00

8-7-5 Supplying and erecting G.l. wall hook, 10 to 15 mm dia and overall length 250 mm including grouting, cement plastering etc. complete.

Each 44 15.84 60.00

8-7-6 Supplying and erecting pipe post made from ISI mark G.I. pipe 40 mm dia 3 m overall length, with two bends, fixed to pipe at the top & bottom, round bended, complete erected with MS flat welded MS bolts 15 cm long duly grouted in wall with necessary clamps, nuts and bolts etc. duly painted with two coats of aluminium paint complete.

Each 1128 85.51 1214.00

8-7-7 Supplying and erecting pipe post made from ISI mark G.I. pipe 25 mm dia 3 m overall length, with two bends, fixed to pipe at the top & bottom, round bended, complete erected with MS flat welded MS bolts 15 cm long duly grouted in wall with necessary clamps, nuts and bolts etc. duly painted with two coats of aluminium paint complete.

Each 845 85.51 931.00

8-7-8 Supplying and erecting guarding loop using G.l. wire No. 8 SWG for L.T. over head line of horizontal formation complete erected with 20 SWG G.l. wire as binding wire and 50 mm. section on each side, complete.

Each 19 16.89 36.00

8-7-9 Supplying and erecting fibre/ PVC spacers for L.T. overhead line 3 to 5 conductors complete erected.

Each 51 16.89 68.00

8-7-10 Supplying and erecting pole clamp made from 50 x 6 mm MS flat for pole or pipe, post complete erected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint.

Each 104 24.28 128.00

8-7-11 Supplying and erecting pole clamp made from 50 x 10 mm MS flat for pole or pipe, post complete erected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. .

Each 153 24.28 177.00

8-7-12 Supplying and erecting ‘D’ type pole clamps, fabricated from 50 x 6 mm MS flat with 15 mm dia. bolts and nut fixed to steel tubular pole duly painted with one coat of red oxide and two coats of aluminium paint.

Each 104 24.28 128.00

8-7-13 Supplying and erecting half clamps for pole made from 50 x 6 mm flat for fixing cross arms by means of 15 mm dia. bolts and nuts painted with one coat of red oxide and two coats of aluminium paint.

Each 63 24.28 87.00

8-7-14 Supplying and erecting half clamps for pole made from 50 x 10 mm flat for fixing cross arms by means of 15 mm dia. bolts and nuts painted with one coat of red oxide and two coats of aluminium paint.

Each 100 24.28 124.00

8-7-15 Supplying and fixing MS base plate 30x30x0.6 cm size fixed to the pole base either by welding or by set screws 12 mm. dia fixed at position.

Each 291 24.28 315.00

8-7-16 Supplying and fixing MS round base plate 25 cm dia meter and 10mm. thick fixed to pole by set screws or welded and fixed at position.

Each 100 24.28 124.00

8-7-17 Supplying and fixing MS pole cap fabricated from MS pipe or cast iron fixed to pole by means of set screws and 75 mm deep.

Each 89 15.84 105.00

8-7-18 Supplying and erecting guarding lace for H.T.O.H. line with 8 SWG G.l. wire to protect the H.T. over head line with binding wire of 20 SWG G.l. wire for 75 mm section on either side.

Each 22 16.89 39.00

8.8 Dismantling

Page 58: Electrical CSR 12-13

8-8-1 Dismantling the existing pole up to 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level.

Each 0 395.89 396.00

8-8-2 Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level.

Each 0 558.47 558.00

8-8-3 Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes.

km 0 801.28 801.00

8-8-4 Dismantling existing lightning arrestor set, insulator complete from DP structure in an approved manner

job 0 59.12 59.00

Chapter : 9 EARTHING (EA) 9.1 Plate,Pipe type Earthing (EA-EP)

9-1-1 Supplying and erecting Galvanised cast iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification No. EA-EP

Each 1656 315.65 1972.00

9-1-2 Supplying and erecting Copper earth plate size 30 x 30 x 0.6 cms. complete with all materials, testing & recording the results as per specification No. EA-EP

Each 2805 357.88 3163.00

9-1-3 Supplying and erecting Galvanised cast iron earth plate size 60 x 60 x 0.6 cms. with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification No. EA-EP

Each 1915 315.65 2231.00

9-1-4 Deleted 9-1-5 Supplying and erecting pipe type earthing with 40mm. dia. G.l. pipe or

20 mm dia. G.l. Rod complete with all materials as per specification No. EA- EP

Each 613 184.75 798.00

9-1-6 (New)

Supplying and erecting Mobilised Earth for mobile earthing made of SS304 L and 250 micro molecularly bonded copper as per specification No EA- MOBI

Each 13449 182.64 13632.00

9-1-7 (New)

Supplying and erecting Copper earth plate size 60 x 60 x 0.315 cms. with funnel with a wire mesh for watering and brick masonry block C.l. cover with TEREC+ maintenance free ground enhancing compound instead of using combination of salt and charcoal complete with all materials, testing & recording the results . One earth pit require one bag of 5 kg of the TEREC+ compound.Requirement of no of bags shall be decided wirh respect to soil resistivity as per specification no ESE -LA

Each 11993 640.81 12634.00

Note :- 1) Resistivity of the soil shall be checked and no of Terrc Compound bags shall be used as per guidelines elaborated in specification 2)Additional GI / Copper wire from earth pit to installation to be provided separately. 3) Item No 9-1-5 shall be used for only for temporary installation 4) Provision of 1 bag of 5 kg. TEREC+ compound is made in item no. 9-1-6. However those who require more than 1 bag TEREC+ compound w.r.t. soil resistivityshall be paid separately @of Rs. 4830/- per bag including of tax.

9.2 Accessories 9-2-1 Supplying and erecting aluminium strip of required sizes used for

earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint in an approved manner with joints required. as per specification No (EA-EP).

Kg. 313 20.06 333.00

9-2-2 Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. as per specification No (EA-EP).

Kg. 598 20.06 618.00

9-2-3 Supplying and erecting G.I. strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joint required. as per specification No (EA-EP).

Kg. 80 20.06 100.00

9-2-4 Supplying and erecting Annealed bare copper wire of high purity of different sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws in an approved manner.

Kg. 548 57.01 605.00

9-2-5 Supplying and erecting G.l. earth wire 14 to 6 SWG complete erected on wall with necessary clamps in an approved manner for earthing or any other purposes with copper lugs cable sockets of 30A & more at each end with necessary cadmium plated double nut & bolts with washers & covering it with bituminous compound.

Kg. 71 20.06 91.00

9.3 Lightning Arrester and Accessories (EA-LAP) 9-3-1 Deleted

Page 59: Electrical CSR 12-13

9-3-2 Deleted 9-3-3 Supplying & erecting conventional spike type air termination suitable

to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation in an approved manner

Each 2296 184.75 2481.00

Note :- For small buildings (one / two storeyed in the hilly and lightning prone area conventional type lightning conductor of item no 9-3-2 shall only be used

Chapter : 10 SUB STATION (SS)

10.1 Transformers (TR)

10-1-1 Supplying and Erecting approved make 63 kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta connected. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 11/ 0.433 kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses below 155 watts at no load, 1250 watts at full load as per IS 2026.) as per specification No SS- TR.

Each 152336 1789.41 154125.00

10-1-2 Supplying and Erecting approved make 100 kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta conn. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 11/ 0.433 kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses below 220 watts at no load, 1800 watts at full load as per IS 2026.) as per specification No SS- TR.

Each 191948 1789.41 193737.00

10-1-3 Supplying and Erecting approved make 160kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta conn. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 11 / 0.433kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses below 400 watts at no load,2400 watts at full load as per IS 2026.) as per specification No SS- TR.

Each 273218 2270.81 275489.00

10-1-4 Supplying and Erecting approved make 200kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta conn. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 11/ 0.433kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses below 500 watts at no load, 3000 watts at full load as per IS 2026.) as per specification No SS- TR.

Each 311759 2270.81 314030.00

10-1-5 Supplying and Erecting approved make 250kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta conn. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 11 / 0.433kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses below 550 watts at no load, 3600 watts at full load as per IS 2026.) as per specification No SS- TR.

Each 360928 2270.81 363199.00

10-1-6 Supplying and Erecting approved make 315kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta conn. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 11 / 0.433kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses below 580 watts at no load, 4200 watts at full load as per IS 2026.) as per specification No SS- TR.

Each 447830 2270.81 450101.00

10-1-7 Supplying and Erecting approved make 500 kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta conn. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 11 / 0.433kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses below 750 watts at no load, 5800 watts at full load as per IS 2026.) as per specification No SS- TR.

Each 607008 2270.81 609279.00

Page 60: Electrical CSR 12-13

10-1-8 Supplying and Erecting approved make 630- kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta conn. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 11 / 0.433kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses below 1000 watts at no load, 7000 watts at full load as per IS 2026.) as per specification No SS- TR.

Each 707740 2270.81 710011.00

10-1-9 Supplying and Erecting approved make 63 kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta conn. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 22 / 0.433kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses 1193 watts at full load as per IS 2026.) as per specification No SS- TR.

Each 167278 2270.81 169549.00

10-1-10 Supplying and Erecting approved make 100 kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta conn. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 22 / 0.433kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses 1717 watts at full load as per IS 2026.) as per specification No SS- TR.

Each 117013 2270.81 119284.00

10-1-11 Supplying and Erecting approved make 160 kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta conn. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 22 / 0.433kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses, 1766 watts at full load as per IS 2026.) as per specification No SS- TR.

Each 306022 2270.81 308293.00

10-1-12 Supplying and Erecting approved make 200 kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta conn. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 22 / 0.433kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses, 2160 watts at full load as per IS 2026.) as per specification No SS- TR.

Each 357298 2270.81 359569.00

10-1-13 Supplying and Erecting approved make 250 kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta conn. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 22 / 0.433kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses , 2540 watts at full load as per IS 2026.) as per specification No SS- TR.

Each 410250 2270.81 412521.00

10-1-14 Supplying and Erecting approved make 315kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta conn. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 22 / 0.433kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses , 3584 watts at full load as per IS 2026.) as per specification No SS- TR.

Each 495471 2270.81 497742.00

10-1-15 Supplying and Erecting approved make 500kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta conn. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 22 / 0.433kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses , 4200 watts at full load as per IS 2026.) as per specification No SS- TR.

Each 676157 2270.81 678428.00

10-1-16 Supplying and Erecting approved make 630 kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta conn. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 22 / 0.433kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses , 4990 watts at full load as per IS 2026.) as per specification No SS- TR.

Each 745842 2270.81 748113.00

Note :- 1) For use of Transformer with aluminium winding for 63/100/200 kVA capacity. (To be used only for Licensee Job), Rates shall be reduced by 15 % from the material rates for Transformer with Copper winding.2) For item No. 10-1-1 & 10-1-2 reduce the material rate by 5% for transformer without of load tap changer.

Page 61: Electrical CSR 12-13

10-1-17 Inspection of faulty distribution transformer 11kV / 22kV on HV side, 415 V on LV side upto 500 kVA capacity in workshop in presence of authority by opening top cover, disconnecting HV & LV studs, tap changer connections; taking out core along with winding for inspection and carrying out necessary tests on HV, LV side, oil, tap-changer etc. checking breather, body condition etc. and submitting inspection report, test reports (oil, insulation, resistance, ratio,etc.) and quotation for repairs, (excluding transportation)

Job 0 2238.08 2238.00

10-1-18 Hiring and maintaining distribution transformer 11kV / 22 kV on HV side 415 V on LV side up to 63 to 200 kVA Capacity. (Hiring for 10 days)

Day 0 13462.29 13462.00

10-1-19 Hiring and maintaining distribution transformer 11 kV / 22 kV on HV side 415 V on LV side up to 250 to 500 kVA Capacity. (Hiring for 10 days)

Day 0 24230.43 24230.00

10-1-20 Hiring and maintaining distribution transformer 11/ 22 kV on HV side 415 V on LV side upto 500 kVA capacity after commissioning. (for subsequent 5 days and part thereof.)

Day 472 0 472.00

Note :- 1)Hiring and maintaining distribution transformer 11/22 kV includes keeping it in working condition with required tools and plant, labour etc 2) The above rates for item no 10-1-18 to 10-1-20 are to be implemented whenever there is a transformer required in lieu of faulty transformer and transportation, erection, testing etc are to be considered separately

10-1-21 Erecting 11kV / 22 kV on HV side 415 V on LV side up to 500 kVA capacity hired/provided transformer on existing plinth / DP structure, making connections on HV & LV side in approved manner, carrying out necessary tests before and after charging upto full load to satisfaction.(including transportation)

Job 8555 1394.58 9950.00

10-1-22 (New)

Supplying and erecting approved make out door type oil immersed aluminium wound 6350/250v 15 KVA SINGLE PHASE transformer confirming to I.S. 2026 specification complete with 5 % continuously rated for full load with standard accessories complete with Test Certificate with with first filling of oil having Vector Group- DYN-11 & first filling of silica gel, as per specification No SS- TR

59082 1266.84 60349.00

10-1-23 (New)

Supplying and erecting approved make out door type oil immersed aluminium wound 6350/250v 25 KVA SINGLE PHASE transformer confirming to I.S. 2026 specification complete with 5 % continuously rated for full load with standard accessories complete with Test Certificate with with first filling of oil having Vector Group- DYN-11 & first filling of silica gel, as per specification No SS- TR

75144 1266.84 76411.00

10-1-24 (New)

Supplying and Erecting BEE approved make Star Rated (3 STAR) 63 kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta connected. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 11/ 0.433 kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses below 380 watts at 50 % loading and 1250 Watt at 100 % Loading as per IS 1180 ( Part 1 ) as per specification No SS- TR.-(STAR)

208098 1907.65 210006.00

10-1-25 (New)

Supplying and Erecting BEE approved make Star Rated (3 STAR) 100 kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta conn. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 11/ 0.433 kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses below 520 watts at 50 % loading and 1800 Watt at 100 % Loading as per IS 1180 ( Part 1 ) as per specification No SS- TR.-(STAR)

263109 1907.65 265017.00

10-1-26 (New)

Supplying and Erecting BEE approved make Star Rated (3 STAR) 160kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta conn. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 11 / 0.433kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses below 770 watts at 50 % loading and 2200 Watt at 100 % Loading as per IS 1180 ( Part 1 ) as per specification No SS- TR.-(STAR)

378732 2383.77 381116.00

10-1-27 (New)

Supplying and Erecting BEE approved make Star Rated (3 STAR) 200kVA ,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type, copper wound transformer with delta conn. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 11/ 0.433kV with HV tapping of +/- 2.5% - 5 % continuously rated for full load with standard accessories complete with Test Certificate with losses below 890 watts at 50 % loading and 2700 Watt at 100 % Loading as per IS 1180 ( Part 1 ) as per specification No SS- TR.-(STAR)

404383 2383.77 406767.00

10.2 Accessories

Page 62: Electrical CSR 12-13

10-2-1 Supplying and erecting approved make 11 kV out door type gang operated air break, triple pole switch 200A, capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of "C" class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp.

Set. 15685 604.92 16290.00

10-2-2 Supplying and erecting approved make 11 kV out door type gang operated air break, triple pole switch 400A, capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of "C" class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp.

Set. 17645 767.49 18412.00

10-2-3 Supplying and erecting approved make 22 kV out door type gang operated air break, triple pole switch 200A, capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of "C" class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp.

Set. 24934 767.49 25701.00

10-2-4 Supplying and erecting approved make 33 kV out door type gang operated air break, triple pole switch 200A, capacity with 3 post pin type insulator double stack per phase, mounted in horizontal position with necessary channels on provided cross arm with adequate length of "C" class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp.

Set. 34184 767.49 34951.00

10-2-5 Supplying and erecting approved make, 11 kV out door type drop out fuse with insulator complete with fuse holders, fuse barrel with metal fitting, fuse element mounted on M.S. channel with working current of 15 Amps capacity complete erected on provided cross arm.

Set. 8204 526.79 8731.00

10-2-6 Supplying and erecting approved make, 22 kV out door type drop out fuse with insulator complete with fuse holders, fuse barrel with metal fitting, fuse element mounted on M.S. channel with working current of 15 Amps capacity complete erected on provided cross arm.

Set. 14093 526.79 14620.00

10-2-7 Supplying and erecting approved make, 33 kV out door type drop out fuse with insulator complete with fuse holders, fuse barrel with metal fitting, fuse element mounted on M.S. channel with working current of 15 Amps capacity complete erected on provided cross arm.

Set. 19304 526.79 19831.00

10-2-8 Supplying and erecting 11 kV fuse barrel with metal fittings. Each 281 25.34 306.00 10-2-9 Supplying and erecting 22 kV fuse barrel with metal fittings. Each 470 25.34 495.00 10-2-10 Supplying and erecting hard drawn copper solid wire No.0 to 6 SWG

complete erected for connections on H.T. sides. kg 570 80.23 650.00

10-2-11 Supplying and erecting extra thick alkathene pipe 10mm. dia erected to enclose bare conductor wires. (use shall be restricted to H.T.)

Mtr. 27 6.33 33.00

10-2-12 Supplying operating rod, suitable for 11/22kV supply with clamps for removing drop out fuses at 6 meters length, 4 pieces each with rain shade with hand grip including earthing chain 1.5 m (Light duty)

Each 2352 0 2352.00

10-2-13 Supplying Heavy duty operating rod, Outer Dia 25 mm & inner dia 20 mm suitable for 11 kV with brass couplings etc for removing drop out fuses at 6 meters length, 4 pieces each with rain shade with hand grip including earthing chain 1.5 m

Each 3476 0 3476.00

10-2-14 Supplying Heavy duty operating rod, Outer Dia 25 mm & inner dia 20 mm suitable for 22/33 kV with brass couplings etc for removing drop out fuses at 6 m length, 4 pieces each with rain shade with hand grip including earthing chain 1.5 m

Each 4122 0 4122.00

10-2-15 Supplying and erecting copper tubular bus 20mm. dia 1.6 mm (16 SWG) thick for the use of high tension over head bus and erected on provided HT insulators with clamps, nuts and bolts complete. (weight per meter of bus is about 1.7 kg.)

Mtr. 969 25.34 994.00

10-2-16 Supplying and erecting clamps, made out of 25x3mm, copper strips to be fixed to tubular bus for connecting the bare copper wire to other equipment, with brass nuts bolts of suitable dia.

Each 97 25.34 122.00

10-2-17 Supplying and erecting anticlimbing devices, fabricated from pole clamps of MS Flat 40x5 mm, with drooping spikes 15 cm. in length, welded to it and erected on pole.

Each 77 25.34 102.00

10-2-18 Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in foundation and painted as per specification No SS-AS/FSG

Each 2306 197.42 2503.00

Note :- For Section less than 1200 mm width, reduce rate by Rs 120/- per 100 mm or part thereof for reduction in width of 1200 mm.

10-2-19 Supplying and erecting 50 x 50 x 6 mm. angle iron as corner support 0.5 m away from the fence support fixed at the middle of the fencing frame and the other side in C.C. foundation of 15 x 15 x 40 cm. complete duly painted with one coat of red oxide and two coats aluminum paint.

Each 854 99.24 953.00

Page 63: Electrical CSR 12-13

10-2-20 Supplying and erecting double leaf hinged door each 1500mm in width x 1850 mm in height using B class ,GI pipe with angle iron supports, chain link wiremesh (jali) complete supported on channel iron, erected in foundation, and painted as per specification no SS-AS/DLD

Each 7445 396.94 7842.00

10-2-21 Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials. (6.044 meters/kg.).

Kg. 76 5.28 81.00

10-2-22 Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated.

Each 60 9.5 70.00

10-2-23 Provided pair of duly tested rubber hand gloves as per IS :340715 suitable for working on 22kV supply.

Each 435 0 435.00

10-2-24 Providing round bottom FIRE Bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook.

Each 402 0 402.00

10-2-25 Providing floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm. angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint.

Each 1773 71.79 1845.00

10-2-26 Supplying and erecting Wall hook 225mm projection for keeping fire buckets made out of 15 mm. dia. M.S. Rod grouted in wall to a depth of minimum 15cms.

Each 40 9.5 50.00

10-2-27 Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal use, scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes)

Each 323 0 323.00

10-2-28 Supplying rubber matting of 6 mm thickness as per IS : 5424 and of required length and breadth with good insulation property for 22 kV.

Sqm. 913 0 913.00

10-2-29 Supplying rubber matting of 12 mm. thickness as per IS : 5424 and of required length and breadth with good insulation property for 22 kV.

Sqm. 1919 0 1919.00

10-2-30 Supplying and fixing PVC Synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness upto 3.3 kV

Sqm. 4022 315.65 4338.00

10-2-31 Supplying and fixing PVC Synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness upto 11 kV

Sqm. 4357 315.65 4673.00

10-2-32 Supplying and fixing PVC Synthetic elastomer electrically insulating mat with class C insulation conforming to IS: 15652 – 2006 having 3mm thickness upto 33 kV

Sqm. 6033 315.65 6349.00

Note :- As old IS No 5424 -1969 is superseded by IS no 15652-2006 , hence the use of rubber matting ( Item No 10-2-28, 10-2-29 ) should be discontinued in new erection.

10-2-33 Supplying shock proof leather Safety Shoes of Electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer.

per Pair1341 0 1341.00

10-2-34 Supplying and erecting D.C.P. type Fire Extinguisher 5 kg capacity cartridge type with Gun Metal cap 150 gram CO2 gas cartridge, powder and brackets conforming to IS 2171-1985 and complete erected with necessary clamps made from 50x6 mm M.S. flat with nuts & bolts grouted in wall complete.

Each 2368 48.56 2417.00

10-2-35 Supplying and erecting D.C.P. type Fire Extinguisher 10 kg capacity cartridge type with Gun Metal cap 150 gram CO2 gas cartridge, powder and brackets conforming to IS 2171-1985 and complete erected with necessary clamps made from 50x6 mm M.S. flat with nuts & bolts grouted in wall complete.

Each 3340 48.56 3389.00

10-2-36 Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. Capacity Cartridge type conf. To IS 2878 Complete erected with necessary clamp made front 50x6 mm. M. S. flat with nut & bolts grouted in wall complete.

Each 8434 48.56 8483.00

10-2-37 Supplying & erecting Carbon Dioxide ( CO2 ) fire extinguisher of 5.5 / 6.5 kg. Capacity Cartridge type conf. To IS 2878 Complete erected with necessary clamp made front 50x6 mm. M. S. flat with nut & bolts grouted in wall complete.

Each 11057 48.56 11106.00

10-2-38 Supplying and erecting ABC powder type 'Ceasefire' type fire extinguisher as per IS : 13849 of 1 kg capacity with necessary clamp for erection on wall.

Each 1709 0 1709.00

10.3 Dismantling 10-3-1 Dismantling the existing Distribution Transformer of any capacity from

the plinth / foundation safely without any damages and storing in safe place.

KVA 0 20.06 20.00

10-3-2 Dismantling existing pole mounted Distribution Transformer safely without any damages and storing it in safe place.

kVA 0 30.62 31.00

Note :- Transportation should be given separately as on actual basis for item no 10.3.1 & 10.3.2

Page 64: Electrical CSR 12-13

10-3-3 Dismantling existing DO / AB switch set complete from D.P. structure in an approved manner.

Set. 0 197.42 197.00

Note :- The rate for item no 10.3.3 are for dismantling and handing over to section office inclusive of transportation upto 25 km, between site and section office.

Chapter 11 : GENERATORS (GEN) 11.1 Generators (GEN)

11-1-1 Supplying portable generator set with petrol start and kerosene run engine suitable to give 1400 VA output at 220 +/-13 V A.C. with rated current of 6.4 A complete with standard accessories as per specification No. GEN-PG

Each 38334 0 38334.00

11-1-2 Supplying portable generator set with petrol start and kerosene run engine suitable to give 2000 VA output at 220 +/-13 V A.C. with rated current of 6.4 A complete with standard accessories as per specification No. GEN-PG

Each 48836 0 48836.00

Note :- Add Rs 2600/- for Diesel Start / Run for Item No 11-1-2 11-1-3 Supplying, Erecting and Commissioning of Diesel generating set with

AMF Panel with alternator of 10 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / water cooled multi-cylinder diesel enginedeveloping suitable BHP at 1500 rpm with 10% overload for 1 hour in 24 hours with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-1968 with voltage regulation +/- 5 % .Both the engine and alternator direct coupled on a common fabricated steel base plate with anti vibratring pad with control panel comprising of standard meters,switchgears, indicators connected with suitable wires/cables.The complete set enclosed in Acoustic enclosure made of 18 SWG CRCA Sheet, sound absorbing material,Rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level upto 75 dB at 1.0 m The engine with first filling of oil,diesel etc.obtaining necessary approval fromElectrical Inspector as per specification No GEN-DG

Each 366050 2732.15 368782.00

11-1-4 Supplying, Erecting and Commissioning of Diesel generating set with AMF Panel with alternator of 15 kVA output continuous rating, 3 Phase, 415 volts, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / water cooled multy cylinder diesel enginedeveloping suitable BHP at 1500 rpm with 10% overload for 1 hour in 24 hours with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-1968 with voltage regulation +/- 5 % .Both the engine and alternator direct coupled on a common fabricated steel base plate with anti vibratring pad with control panel comprising of standard meters,switchgears, indicators connected with suitable wires/cables.The complete set enclosed in Acoustic enclosure made of 18 SWG CRCA Sheet, sound absorbing material,Rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level upto 75 dB at 1.0 mtr.The engine with first filling of oil,diesel etc.obtaining necessary approval fromElectrical Inspector as per specification no GEN-DG

Each 407654 3697.06 411351.00

11-1-5 Supplying, Erecting and Commissioning of Diesel generating set with AMF Panel with alternator of 20 kVA output continuous rating, 3 Phase, 415V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / water cooled multy cylinder diesel enginedeveloping suitable BHP at 1500 rpm with 10% overload for 1 hour in 24 hours with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-1968 with voltage regulation +/- 5 % .Both the engine and alternator direct coupled on a common fabricated steel base plate with anti vibratring pad with control panel comprising of standard meters,switchgears, indicators connected with suitable wires/cables.The complete set enclosed in Acoustic enclosure made of 18 SWG CRCA Sheet, sound absorbing material,Rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level upto 75 dB at 1.0 m.The engine with first filling of oil,diesel etc.obtaining necessary approval fromElectrical Inspector as per specification no GEN-DG

Each 485526 3697.06 489223.00

Page 65: Electrical CSR 12-13

11-1-6 Supplying, Erecting and Commissioning of Diesel generating set with AMF Panel with alternator of 25 kVA output continuous rating, 3 Phase, 415V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / water cooled multy cylinder diesel enginedeveloping suitable BHP at 1500 rpm with 10% overload for 1 hour in 24 hours with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-1968 with voltage regulation +/- 5 % .Both the engine and alternator direct coupled on a common fabricated steel base plate with anti vibratring pad with control panel comprising of standard meters,switchgears, indicators connected with suitable wires/cables.The complete set enclosed in Acoustic enclosure made of 18 SWG CRCA Sheet, sound absorbing material,Rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level upto 75 dB at 1.0 m.The engine with first filling of oil,diesel etc.obtaining necessary approval fromElectrical Inspector as per specification no GEN-DG

Each 525127 3697.06 528824.00

11-1-7 Supplying, Erecting and Commissioning of Diesel generating set with AMF Panel with alternator of 30 kVA output continuous rating, 3 Phase, 415V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / water cooled multy cylinder diesel enginedeveloping suitable BHP at 1500 rpm with 10% overload for 1 hour in 24 hours with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-1968 with voltage regulation +/- 5 % .Both the engine and alternator direct coupled on a common fabricated steel base plate with anti vibratring pad with control panel comprising of standard meters,switchgears, indicators connected with suitable wires/cables.The complete set enclosed in Acoustic enclosure made of 18 SWG CRCA Sheet, sound absorbing material,Rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level upto 75 dB at 1.0 m.The engine with first filling of oil,diesel etc.obtaining necessary approval fromElectrical Inspector as per specification no GEN-DG

Each 574873 3697.06 578570.00

11-1-8 Supplying, Erecting and Commissioning of Diesel generating set with AMF Panel with alternator of 40 kVA output continuous rating, 3 Phase, 415V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / water cooled multy cylinder diesel enginedeveloping suitable BHP at 1500 rpm with 10% overload for 1 hour in 24 hours with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-1968 with voltage regulation +/- 5 % .Both the engine and alternator direct coupled on a common fabricated steel base plate with anti vibratring pad with control panel comprising of standard meters,switchgears, indicators connected with suitable wires/cables.The complete set enclosed in Acoustic enclosure made of 18 SWG CRCA Sheet, sound absorbing material,Rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level upto 75 dB at 1.0 m The engine with first filling of oil,diesel etc.obtaining necessary approval fromElectrical Inspector as per specification no GEN-DG

Each 652400 4436.05 656836.00

11-1-9 Supplying, Erecting and Commissioning of Diesel generating set with AMF Panel with alternator of 50 kVA output continuous rating, 3 Phase, 415V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / water cooled multy cylinder diesel enginedeveloping suitable BHP at 1500 rpm with 10% overload for 1 hour in 24 hours with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-1968 with voltage regulation +/- 5 % .Both the engine and alternator direct coupled on a common fabricated steel base plate with anti vibratring pad with control panel comprising of standard meters,switchgears, indicators connected with suitable wires/cables.The complete set enclosed in Acoustic enclosure made of 18 SWG CRCA Sheet, sound absorbing material,Rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level upto 75 dB at 1.0 m The engine with first filling of oil,diesel etc.obtaining necessary approval fromElectrical Inspector as per specification no GEN-DG

Each 774108 4436.05 778544.00

11-1-10 Supplying, Erecting and Commissioning of Diesel generating set with AMF Panel with alternator of 62.5 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / water cooled multy cylinder diesel enginedeveloping suitable BHP at 1500 rpm with 10% overload for 1 hour in 24 hours with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-1968 with voltage regulation +/- 5 % .Both the engine and alternator direct coupled on a common fabricated steel base plate with anti vibratring pad with control panel comprising of standard meters,switchgears, indicators connected with suitable wires/cables.The complete set enclosed in Acoustic enclosure made of 18 SWG CRCA Sheet, sound absorbing material,Rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level upto 75 dB at 1.0 m.The engine with first filling of oil,diesel etc.obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG

Each 792281 4436.05 796717.00

Page 66: Electrical CSR 12-13

11-1-11 Supplying, Erecting and Commissioning of Diesel generating setwith AMF Panel with alternator of 75 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C a totally enclosed water cooled multy cylinder diesel enginedeveloping suitable BHP at 1500 rpm with 10% overload for 1 hour in 24 hours with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-1968 with voltage regulation +/- 5 % .Both the engine and alternator direct coupled on a common fabricated steel base plate with anti vibratring pad with control panel comprising of standard meters,switchgears, indicators connected with suitable wires/cables.The complete set enclosed in Acoustic enclosure made of 18 SWG CRCA Sheet, sound absorbing material,Rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level upto 75 dB at 1.0 mtr.The engine with first filling of oil,diesel etc.obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG

Each 801277 6269.8 807547.00

11-1-12 Supplying, Erecting and Commissioning of Diesel generating set with AMF Panel and with alternator of 82.5 kVA output continuous rating, 3 Phase, 415V, 50c/s 0.8 p. f. A.C a totally enclosed water cooled multy cylinder diesel enginedeveloping suitable BHP at 1500 rpm with 10% overload for 1 hour in 24 hours with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-1968 with voltage regulation +/- 5 % .Both the engine and alternator direct coupled on a common fabricated steel base plate with anti vibratring pad with control panel comprising of standard meters,switchgears, indicators connected with suitable wires/cables.The complete set enclosed in Acoustic enclosure made of 18 SWG CRCA Sheet, sound absorbing material,Rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level upto 75 dB at 1.0 mtr.The engine with first filling of oil,diesel etc.obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG

Each 879828 6269.8 886098.00

11-1-13 Supplying, Erecting and Commissioning of Diesel generating set with AMF Panel with alternator of 100 kVA output continuous rating, 3 Phase, 415V, 50c/s 0.8 p. f. A.C a totally enclosed water cooled multy cylinder diesel enginedeveloping suitable BHP at 1500 rpm with 10% overload for 1 hour in 24 hours with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-1968 with voltage regulation +/- 5 % .Both the engine and alternator direct coupled on a common fabricated steel base plate with anti vibratring pad with control panel comprising of standard meters,switchgears, indicators connected with suitable wires/cables.The complete set enclosed in Acoustic enclosure made of 18 SWG CRCA Sheet, sound absorbing material,Rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level upto 75 dB at 1.0 mtr.The engine with first filling of oil,diesel etc.obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG

Each 1002143 7521.86 1009665.00

11-1-14 Supplying, Erecting and Commissioning of Diesel generating set with AMF Panelwith alternator of 125 kVA output continuous rating, 3 Phase, 415V, 50c/s 0.8 p. f. A.C a totally enclosed water cooled multy cylinder diesel enginedeveloping suitable BHP at 1500 rpm with 10% overload for 1 hour in 24 hours with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-1968 with voltage regulation +/- 5 % .Both the engine and alternator direct coupled on a common fabricated steel base plate with anti vibratring pad with control panel comprising of standard meters,switchgears, indicators connected with suitable wires/cables.The complete set enclosed in Acoustic enclosure made of 18 SWG CRCA Sheet, sound absorbing material,Rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level upto 75 dB at 1.0 mtr.The engine with first filling of oil,diesel etc.obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG

Each 1066106 7521.86 1073628.00

11-1-15 Supplying, Erecting and Commissioning of Diesel generating set with AMF Panel with alternator of 140 kVA output continuous rating, 3 Phase, 415V, 50c/s 0.8 p. f. A.C a totally enclosed water cooled multy cylinder diesel enginedeveloping suitable BHP at 1500 rpm with 10% overload for 1 hour in 24 hours with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-1968 with voltage regulation +/- 5 % .Both the engine and alternator direct coupled on a common fabricated steel base plate with anti vibratring pad with control panel comprising of standard meters,switchgears, indicators connected with suitable wires/cables.The complete set enclosed in Acoustic enclosure made of 18 SWG CRCA Sheet, sound absorbing material,Rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level upto 75 dB at 1.0 mtr.The engine with first filling of oil,diesel etc.obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG

Each 1287637 7521.86 1295159.00

Page 67: Electrical CSR 12-13

11-1-16 Supplying, Erecting and Commissioning of Diesel generating set with AMF Panel with alternator of 160 kVA output continuous rating, 3 Phase, 415V, 50c/s 0.8 p. f. A.C a totally enclosed water cooled multy cylinder diesel enginedeveloping suitable BHP at 1500 rpm with 10% overload for 1 hour in 24 hours with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-1968 with voltage regulation +/- 5 % .Both the engine and alternator direct coupled on a common fabricated steel base plate with anti vibratring pad with control panel comprising of standard meters,switchgears, indicators connected with suitable wires/cables.The complete set enclosed in Acoustic enclosure made of 18 SWG CRCA Sheet, sound absorbing material,Rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level upto 75 dB at 1.0 mtr.The engine with first filling of oil,diesel etc.obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG

Each 1394372 8357.98 1402730.00

11-1-17 Supplying, Erecting and Commissioning of Diesel generating set with AMF Panel with alternator of 180 kVA output continuous rating, 3 Phase, 415V, 50c/s 0.8 p. f. A.C a totally enclosed water cooled multy cylinder diesel enginedeveloping suitable BHP at 1500 rpm with 10% overload for 1 hour in 24 hours with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-1968 with voltage regulation +/- 5 % .Both the engine and alternator direct coupled on a common fabricated steel base plate with anti vibratring pad with control panel comprising of standard meters,switchgears, indicators connected with suitable wires/cables.The complete set enclosed in Acoustic enclosure made of 18 SWG CRCA Sheet, sound absorbing material,Rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level upto 75 dB at 1.0 mtr.The engine with first filling of oil,diesel etc.obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG

Each 1569689 9242.65 1578932.00

11-1-18 Supplying, Erecting and Commissioning of Diesel generating set with AMF Panel with alternator of 200 kVA output continuous rating, 3 Phase, 415V, 50c/s 0.8 p. f. A.C a totally enclosed water cooled multy cylinder diesel enginedeveloping suitable BHP at 1500 rpm with 10% overload for 1 hour in 24 hours with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-1968 with voltage regulation +/- 5 % .Both the engine and alternator direct coupled on a common fabricated steel base plate with anti vibratring pad with control panel comprising of standard meters,switchgears, indicators connected with suitable wires/cables.The complete set enclosed in Acoustic enclosure made of 18 SWG CRCA Sheet, sound absorbing material,Rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level upto 75 dB at 1.0 mtr.The engine with first filling of oil,diesel etc.obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG

Each 1691973 9242.65 1701216.00

11-1-19 Supplying, Erecting and Commissioning of Diesel generating setwith AMF Panel with alternator of 250 kVA output continuous rating, 3 Phase, 415V, 50c/s 0.8 p. f. A.C a totally enclosed water cooled multy cylinder diesel enginedeveloping suitable BHP at 1500 rpm with 10% overload for 1 hour in 24 hours with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-1968 with voltage regulation +/- 5 % .Both the engine and alternator direct coupled on a common fabricated steel base plate with anti vibratring pad with control panel comprising of standard meters,switchgears, indicators connected with suitable wires/cables.The complete set enclosed in Acoustic enclosure made of 18 SWG CRCA Sheet, sound absorbing material,Rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level upto 75 dB at 1.0 mtr.The engine with first filling of oil,diesel etc.obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG

Each 2113010 9242.65 2122253.00

11-1-20 Supplying, Erecting and Commissioning of Diesel generating set with AMF Panel with alternator of 5 kVA output continuous rating, single Phase, 230V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled multy cylinder diesel enginedeveloping suitable BHP at 1500 rpm with 10% overload for 1 hour in 24 hours with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-1968 with voltage regulation +/- 5 % .Both the engine and alternator direct coupled on a common fabricated steel base plate with anti vibratring pad with control panel comprising of standard meters,switchgears, indicators connected with suitable wires/cables.The complete set enclosed in Acoustic enclosure made of 18 SWG CRCA Sheet, sound absorbing material,Rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level upto 75 dB at 1.0 mtr.The engine with first filling of oil,diesel etc.obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG

Each 357148 2380.6 359529.00

Page 68: Electrical CSR 12-13

11-1-21 Supplying, Erecting and Commissioning of Diesel generating set with AMF Panel with alternator of 10 kVA output continuous rating, single Phase, 230V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled multy cylinder diesel enginedeveloping suitable BHP at 1500 rpm with 10% overload for 1 hour in 24 hours with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-1968 with voltage regulation +/- 5 % .Both the engine and alternator direct coupled on a common fabricated steel base plate with anti vibratring pad with control panel comprising of standard meters,switchgears, indicators connected with suitable wires/cables.The complete set enclosed in Acoustic enclosure made of 18 SWG CRCA Sheet, sound absorbing material,Rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level upto 75 dB at 1.0 mtr.The engine with first filling of oil,diesel etc.obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG

Each 396582 2732.15 399314.00

1) DG Set rating for altitudes more than 150 m above mean sea level shall be derated at 3.5 % for every 300 m above 150 m mean sea level.

Chapter 12 : WATER PUMPS (WP) 12.1 Centrifugal Pumps (CGP)

12-1-1 Supplying and erecting Centrifugal water pump (Monoblock), 230 V, single phase 50 cycles A.C.supply of 0.5 HP of specified discharge, head & size of suction, delivery pipes, on provided C.C.foundation as per specification No. WP-CGP

Each 5638 184.75 5823.00

12-1-2 Supplying and erecting Centrifugal water pump (Monoblock), 230 V, single phase 50 cycles A.C.supply of 1 HP of specified discharge, head & size of suction, delivery pipes, on provided C.C.foundation as per specification No. WP-CGP

Each 8719 184.75 8904.00

12-1-3 Supplying and erecting Centrifugal water pump (Monoblock), 230V, single phase 50 cycles A.C.supply of 1.5 HP of specified discharge, head & size of suction, delivery pipes, on provided C.C.foundation as per specification No. WP-CGP

Each 10920 184.75 11105.00

12-1-4 Supplying and erecting Centrifugal water pump (Monoblock), 230V, single phase 50 cycles A.C.supply of 2 HP of specified discharge, head & size of suction, delivery pipes, on provided C.C.foundation as per specification No. WP-CGP

Each 12160 184.75 12345.00

12-1-5 Supplying and erecting Centrifugal water pump (Monoblock), 415V, three phase 50 cycles A.C.supply of 2 HP with discharge 2.2 /4.1Liters per second (LPS) for head of 8 /26 m and 50 mm suction/ 40 mm delivery pipe, on provided C.C.foundation as per specification No. WP-CGP

Each 13536 396.94 13933.00

12-1-6 Supplying and erecting Centrifugal water pump (Monoblock), 415V, three phase 50 cycles A.C.supply of 3 HP with discharge 2 /4.9 Liters per second (LPS) for head of 14/36 and 50 mm suction/ 40 mm delivery pipe on provided c.c. foundation as per specification No. WP-CGP

Each 17376 396.94 17773.00

12-1-7 Supplying and erecting Centrifugal water pump (Monoblock), 415V, three phase 50 cycles A.C.supply of 3 HP with discharge 4.9 /9.2 Liters per second (LPS) for head of 10/26 mtrs and 65 mm suction/ 50 mm delivery pipe on provided c.c. foundation as per specification No. WP-CGP

Each 17376 396.94 17773.00

12-1-8 Supplying and erecting Centrifugal water pump (Monoblock), 415 V, three phase 50 cycles A.C.supply of 3 HP with discharge of 2 /4.1Liters per second (LPS) for head of 36/52 m and 50 mm suction/ 40 mm delivery pipe on provided c c foundation as per specification No. WP-CGP

Each 17376 396.94 17773.00

12-1-9 Supplying and erecting Centrifugal water pump (Monoblock), 415 V, three phase 50 cycles A.C.supply of 5 HP with discharge 2 /4.1 Liters per second (LPS) for head of 36/52m and 50 mm suction/ 40 mm delivery pipe on provided c c foundation as per specification No. WP-CGP

Each 22171 396.94 22568.00

12-1-10 Supplying and erecting Centrifugal water pump (Monoblock), 415 V, three phase 50 cycles A.C.supply of 5 HP with discharge of 5.8/8.5 Liters per second (LPS) for head of 20 /36 m and 65 mm suction/ 50 mm delivery pipe on provided c c foundation as per specification No. WP-CGP

Each 22137 396.94 22534.00

12-1-11 Supplying and erecting ISI mark Centrifugal water pump (Monoblock) 415V, three phase 50 cycles A.C.supply of 7.5 HP with discharge 4.5/8.6 Liters per second (LPS) for head of 32 /52 m and 65 mm suction/ 50 mm delivery pipe of size or with discharge of 11.1/19.9 Liters per second (LPS) for head of 16/30m and 80 mm suction/ 65 mm delivery pipe of size,on provided c c foundation as per specification No. WP-CGP

Each 26207 978.63 27186.00

12-1-12 Supplying and erecting ISI mark Centrifugal water pump (Monoblock) 415 V, three phase 50 cycles A.C.supply of 10 HP with discharge of 9.6 / 21.6 Liters per second (LPS) for head of 18 / 40 m and 80 mm suction/ 65 mm delivery pipe of size or with discharge 4.3 / 7.8Liters per second (LPS) for head of 40 / 64 m and 65 mm suction/ 50 mm delivery pipe of size on provided c c foundation as per specification No. WP-CGP

Each 33829 1041.98 34871.00

Page 69: Electrical CSR 12-13

12-1-13 Supplying and erecting ISI mark Centrifugal water pump (Monoblock), 415V, three phase 50 cycles A.C.supply of 12.5 HP with discharge of 7/ 19.6 discharge/Liters per second (LPS) for head of 20 / 48 mtrs and 80 mm suction/ 65 mm delivery pipe of size or with discharge 20 / 33.5 Liters per second (LPS) for head of 18 / 30 m and 100 mm suction/ 100 mm delivery pipe of size,on provided c c foundation as per specification No. WP-CGP

Each 39915 1041.98 40957.00

12-1-14 Supplying and erecting ISI mark Centrifugal water pump (Monoblock),415 V, three phase 50 cycles A.C.supply of 15 HP with discharge 10.5 /19.4 Liters per second (LPS) for head of 30 / 54 m and 80 mm suction/ 65 mm delivery pipe of size or with discharge of 17.5 / 36.8 Liters per second (LPS) for head of 18 / 36 m and 100 mm suction/ 100 mm delivery pipe of size, on provided c c foundation as per specification No. WP- CGP

Each 44795 1104.26 45899.00

12-1-15 Supplying and erecting ISI mark Centrifugal water pump (Monoblock) 415 V, three phase 50 cycles A.C.supply of 20 HP with discharge of 14 / 33.8 Liters per second (LPS) for head of 18 / 52 m and 100 mm suction/ 80 mm delivery pipe of size on provided c c foundation as per specification No. WP-CGP

Each 63528 1104.26 64632.00

Note :- 1) Preferably energy efficient motors with p.f above 0.9 shall be used.

12.2 Ejecto type Water Pump (EJP) 12-2-1 Deleted 12-2-2 Supplying and erecting ejecto type water pump 3 phase 2 H.P.

multistaged with brass venturi and having suction pipe 40 mm. dia., pressure pipe 32 mm. dia. and delivery pipe 32 mm. dia. with discharge capacity 22/16 LPM for 48/60 m suction head respectively with maximum discharge head of 18 metre complete erected as per specification No. WP- EJP

Each 19807 1749.29 21556.00

12-2-3 Supplying and erecting ejecto type water pump 3 phase 1.5 H.P. multistaged with brass venturi and having suction pipe 40 mm. dia., pressure pipe 32 mm. dia. and delivery pipe 32 mm. dia. with discharge capacity 23/15 LPM for 39/51 m suction head respectively with maximum discharge head of 15 metre complete erected as per specification No. WP- EJP

Each 13521 1749.29 15270.00

12-2-4 Supplying and erecting ejecto type water pump single phase 1.5 H.P. multistaged with brass venturi and having suction pipe 40 mm. dia., pressure pipe 32 mm. dia. and delivery pipe 32 mm. dia. with discharge capacity 23/15 LPM for 39/51 m suction head respectively with maximum discharge head of 15 metre complete erected as per specification no. WP- EJP

Each 14625 1749.29 16374.00

Note :- 1) Preferably energy efficient motors with p.f above 0.9 shall be used. 2)For additional depth of each 3 mtrs or part thereof add Rs.50/- per 3 meter, in the rates of item no. 12-2-7

12.3 Submersible Pumps for Bore wells (SMP) 12-3-1 Supplying and erecting submersible pumpset of required HP with

415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 20 to 80 LPM discharge at 55 to 25 mtr head & (max efficiency at 41 m head & 50 Ipm discharge & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 27880 1749.29 29629.00

12-3-2 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell ,suitable for 70 to 250 LPM discharge at 44 to 24 m head & (max efficiency at 38 m head & 160 Ipm discharge & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 28700 1749.29 30449.00

12-3-3 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, 3 H.P. (2 Stage) suitable for 200 to 500 LPM discharge at 21 to 11 m head & (max efficiency at 19 m head & 300 Ipm) discharge & delievery pipeline 80 mm dia a necessary H. type clamp. As per specification No. WP-SMP

Each 26426 1749.29 28175.00

12-3-4 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 20 to 80 LPM discharge at 91 to 42 m head & (max efficiency at 68 m head & 50 Ipm) discharge & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 24490 1749.29 26239.00

12-3-5 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 100 to 250 LPM discharge at 45 to 24 mtr head & (max efficiency at 38 mtr head & 250 Ipm discharge & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 25569 1749.29 27318.00

Page 70: Electrical CSR 12-13

12-3-6 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 70 to 250 LPM discharge at 65 to 36 mtr head & (max efficiency at 57 mtr head & 160 Ipm discharge & delivery pipe of necessary diameterwith a necessary H. type clamp. As per specification No. WP-SMP

Each 26874 1749.29 28623.00

12-3-7 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 250 to 700 LPM discharge at 33 to 15 m head & (max efficiency at 24 m head & 500 Ipm discharge & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 30601 1749.29 32350.00

12-3-8 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 400 to 900 LPM discharge at 20 to 12 m head & (max efficiency at 16 m head & 700 Ipm discharge & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 28588 1749.29 30337.00

12-3-9 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 20 to 80 LPM discharge at 129 to 59 m head & (max efficiency at 95 m head & 50 Ipm discharge & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 31648 2995.02 34643.00

12-3-10 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 70 to 250 LPM discharge at 87 to 48 m head & (max efficiency at 76 m head & 160 Ipm discharge & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 26328 2995.02 29323.00

12-3-11 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 60 to 175 LPM discharge at 97 to 56 m head & (max efficiency at 79 m head & 125 Ipm discharge &delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 32579 2995.02 35574.00

12-3-12 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 100 to 350 LPM discharge at 56 to 30 m head & (max efficiency at 47 m head & 250 Ipm discharge &delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 27920 2995.02 30915.00

12-3-13 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 200 to 500 LPM discharge at 42 to 22 m head & (max efficiency at 34 m head & 350 Ipm discharge & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 26819 2995.02 29814.00

12-3-14 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 300 to 850 LPM discharge at 33 to 10 m head & (max efficiency at 24 m head & 600 Ipm discharge & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 26240 2995.02 29235.00

12-3-15 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 300 to 850 LPM discharge at 33 to 10 mtr head & (max efficiency at 33 mtr head & 600 Ipm discharge & necessary diameter delivery pipe line with a necessary H. type clamp. As per specification no. WP-SMP

Each 33204 2995.02 36199.00

12-3-16 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 100 to 350 LPM discharge at 67 to 36 m head & (max efficiency at 57 m head & 250 Ipm discharge & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 30193 2995.02 33188.00

12-3-17 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 60 to 175 LPM discharge at 113 to 66 m head & (max efficiency at 92 m head & 125 Ipm discharge &delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 36045 2995.02 39040.00

12-3-18 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 200 to 500 LPM discharge at 52 to 28 m head & (max efficiency at 42 m head & 350 Ipm discharge &delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 34070 2995.02 37065.00

12-3-19 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 250 to 700 LPM discharge at 44 to 20 m head & (max efficiency at 32 m head & 500 Ipm discharge & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 32653 2995.02 35648.00

12-3-20 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 20 to 80 LPM discharge at 184 to 84 m head & (max efficiency at 136 m head & 50 Ipm discharge & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 39475 2995.02 42470.00

Page 71: Electrical CSR 12-13

12-3-21 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 300 to 850 LPM discharge at 44 to 14 m head & (max efficiency at 32 m head & 600 Ipm discharge & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 36717 2995.02 39712.00

12-3-22 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 250 to 700 LPM discharge at 55 to 25 m head & (max efficiency at 40 m head & 500 Ipm discharge & delivery pipe of necessary diameter with a necessary H. type clamp. As per specification o. WP-SMP

Each 39065 2995.02 42060.00

12-3-23 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 60 to 175 LPM discharge at 130 to 75 m head & (max efficiency at 106 m head & 125 Ipm discharge & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 39884 2995.02 42879.00

12-3-24 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 20 to 80 LPM discharge at 221 to 101 m head & (max efficiency at 163 m head & 50 Ipm discharge &delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 42121 2995.02 45116.00

12-3-25 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 20 to 80 LPM discharge at 258 to 118 m head & (max efficiency at 190 m head & 50 Ipm discharge &delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 48793 2995.02 51788.00

12-3-26 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 60 to 175 LPM discharge at 146 to 85 m head & (max efficiency at 119 m head & 25 Ipm discharge & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 42792 2995.02 45787.00

12-3-27 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 300 to 850 LPM discharge at 55 to 17 m head & (max efficiency at 40 m head & 600 Ipm discharge &delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 39065 2995.02 42060.00

12-3-28 Supplying and erectingsubmersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 400 to 900 LPM discharge at 41 to 25 m head & (max efficiency at 32 m head & 700 Ipm discharge & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 37648 2995.02 40643.00

12-3-29 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 70 to 250 LPM discharge at 153 to 84 m head & (max efficiency at 133 m head & 160 Ipm discharge & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 43761 2995.02 46756.00

12-3-30 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 60 to 175 LPM discharge at 162 to 94 m head & (max efficiency at 132 m head & 125 Ipm discharge & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 47376 2995.02 50371.00

12-3-31 Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, suitable for 20 to 80 LPM discharge at 294 to 134 m head & (max efficiency at 218 m head & 50 Ipm discharge & necessary diameter delivery pipe line with a necessary H. type clamp as per specification No. WP-SMP

Each 55576 2995.02 58571.00

12-3-32 Supplying and erecting submersible pumpset suitable for 150 mm dia. borewell of required HP with 230V 50 cycles A.C. supply, with delievery head from 72 to 20 m and discharge from 10 to 50 Itrs per minute (Max.efficiency at 52 m head & 30 Itr discharge & delivery pipe of necessary diameter) erected with necessary H. type clamps as per specification No. WP-SMP

Each 28700 1749.29 30449.00

12-3-33 Supplying and erecting submersible pumpset suitable for 150 mm dia. borewell of required HP with, 230V 50 cycles A.C., with delievery head from 84 to 40 m and discharge from 30 to 90 Itrs per minute (Max.efficiency at 69 m head & 60 Itr discharge & delivery pipe of necessary diameter) erected with necessary H. type clamps as per specification No. WP-SMP

Each 29669 1749.29 31418.00

12-3-34 Supplying and erecting submersible pumpset suitable for 150 mm dia. borewellof required HP with, 230V 50 cycles A.C, with delievery head from 42 to 20 mtrs and discharge from 30 to 90 Itrs per minute (Max.efficiency at 34 mtr head & 60 Itr discharge & delivery pipe of necessary diameter) erected with necessary H. type clamps as per specification no. WP-SMP

Each 25322 1749.29 27071.00

12-3-35 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with 230 V 50 cycles A. C. supply, suitable for 10 to 50 LPM discharge at 45 to 13 m head & (Max. effciency at 33 m head 30 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 18971 1749.29 20720.00

Page 72: Electrical CSR 12-13

12-3-36 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with, 230 V 50 cycles A. C., suitable for 10 to 50 LPM discharge at 54 to 15 m head & (Max. effciency at 39 m head 30 LPM discharge ) &delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 18509 1749.29 20258.00

12-3-37 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with, 230 V 50 cycles A.C., suitable for 10 to 50 LPM discharge at 72 to 20 m head & (Max. effciency at 33 m. head 30 LPM discharge ) &delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 20131 1749.29 21880.00

12-3-38 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with 230 V 50 cycles A. C., suitable for 85 to 170 LPM discharge at 32 to 12 mtr. head & (Max. effciency at 24 m head 130 LPM discharge) & delivery pipe of necessary diameter with a necessary H. type clamp. As per specification No. WP-SMP

Each 17096 1749.29 18845.00

12-3-39 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewellof required HP with, 230 V 50 cycles A.C., suitable for 30 to 90 LPM discharge at 42 to 20 m head & (Max. effciency at 34 mtr. head 60 LPM discharge) & delivery pipe of necessary diameter with a necessary H. type clamp. As per specification No. WP-SMP

Each 17667 1749.29 19416.00

12-3-40 Supplying and erecting submersible pumpset suitable for 100 mm dia. Borewell of required HP with , 230 V 50 cycles A. C., suitable for 30 to 90 LPM discharge at 51 to 25 m head & (Max. effciency at 42 m head 60 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 18408 1749.29 20157.00

12-3-41 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with ,230 V 50 cycles A. C., suitable for 10 to 50 LPM discharge at 32 to 12 m head & (Max. effciency at 26 m head 30 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 21587 1749.29 23336.00

12-3-42 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with, 230 V 50 cycles A. C., suitable for 10 to 50 LPM discharge at 109 to 30 m head & (Max. effciency at 78 m head 30 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 24153 1749.29 25902.00

12-3-43 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with,230 V 50 cycles A.C., suitable for 10 to 50 LPM discharge at 127 to 35 m head & (Max. effciency at 91 m head 30 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 20291 1749.29 22040.00

12-3-44 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with , 230 V 50 cycles A. C, suitable for 30 to 90 LPM discharge at 84 to 40 m head & (Max. effciency at 69 m head 60 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 24003 1749.29 25752.00

12-3-45 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with, 230 V 50 cycles A. C., suitable for 10 to 50 LPM discharge at 127 to 35 m head & (Max. effciency at 91 m head 30 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 27460 1749.29 29209.00

12-3-46 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with, 230 V 50 cycles A.C., suitable for 10 to 50 LPM discharge at 144 to 40 m head & (Max. effciency at 104 m head 30 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 28629 1749.29 30378.00

12-3-47 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with-, 230 V 50 cycles A.C., suitable for 85 to 170 LPM discharge at 43 to 18 m head & (Max. effciency at 33 m head 130 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp. As per specification No. WP-SMP

Each 19817 1749.29 21566.00

12-3-48 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell --do--,230 V 50 cycles A.C, suitable for 10 to 50 LPM discharge at 160 to 45 m head & (Max. effciency at 116 m head 30 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp. As per specification No. WP-SMP

Each 31407 1749.29 33156.00

12-3-49 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP 415 V 50 cycles A.C, suitable for 10 to 50 LPM discharge at 45 to13 m head & (Max. effciency at 33 m head 30 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 17315 1749.29 19064.00

Page 73: Electrical CSR 12-13

12-3-50 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with, 415 V 50 cycles A. C., suitable for 10 to 50 LPM discharge at 54 to 15 m head & (Max. effciency at 39 m head 30 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 17906 1749.29 19655.00

12-3-51 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewellof required HP with, 415 V 50 cycles A. C, suitable for 10 to 50 LPM discharge at 72 to 20 m head & (Max. effciency at 52 m head 30 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp. As per specification No. WP-SMP

Each 19226 1749.29 20975.00

12-3-52 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with , 415 V 50 cycles A. C, suitable for 85 to 170 LPM discharge at 32 to 12 m head & (Max. effciency at 24 m head 130 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp. As per specification No. WP-SMP

Each 17252 1749.29 19001.00

12-3-53 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with,415 V 50 cycles A. C., suitable for 30 to 90 LPM discharge at 42 to 20 m head & (Max. effciency at 34 m head 60 LPM discharge ) & with a necessary H. type clamp as per specification No. WP-SMP

Each 17302 1749.29 19051.00

12-3-54 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with, 415 V 50 cycles A. C., suitable for 30 to 90 LPM discharge at 51 to 25 m head & (Max. effciency at 42 m head 60 LPM discharge ) &delivery pipe of necessary diameter with a necessary H. type clamp. As per specification No. WP-SMP

Each 18044 1749.29 19793.00

12-3-55 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with, 415 V 50 cycles A. C., suitable for 10 to 50 LPM discharge at 90 to 25 m head & (Max. effciency at 66 m head 30 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp. As per specification No. WP-SMP

Each 22494 1749.29 24243.00

12-3-56 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with, 415 V 50 cycles A. C., suitable for 10 to 50 LPM discharge at 109 to 30 m head & (Max. effciency at 78 m head 30 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 23789 1749.29 25538.00

12-3-57 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with-, 415 V 50 cycles A. C., suitable for 30 to 90 LPM discharge at 63 to 30 m head & (Max. effciency at 51m head 60 LPM discharge ) &delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 18798 1749.29 20547.00

12-3-58 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with-, 415 V 50 cycles A. C, suitable for 30 to 90 LPM discharge at 84 to 40 m head & (Max. effciency at 69 m head 60 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 22431 1749.29 24180.00

12-3-59 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewellof required HP with, 415 V 50 cycles A. C., suitable for 10 to 50 LPM discharge at 127 to 35 m head & (Max. effciency at 91 m head 30 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 25763 1749.29 27512.00

12-3-60 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with,415 V 50 cycles A. C., suitable for 10 to 50 LPM discharge at 144 to 40 m head & (Max. effciency at 104 m head 30 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 20649 1749.29 22398.00

12-3-61 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with , 415 V 50 cycles A. C., suitable for 85 to 170 LPM discharge at 43 to 18 m head & (Max. effciency at 91 m head 130 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 18333 1749.29 20082.00

12-3-62 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with, 415 V 50 cycles A. C., suitable for 10 to 50 LPM discharge at 160 to 45 m head & (Max. effciency at 116 m head 30 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 29006 1749.29 30755.00

12-3-63 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with, 415 V 50 cycles A. C., suitable for 85 to 170 LPM discharge at 54 to 21m head & (Max. effciency at 11m head 130 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 22582 1749.29 24331.00

Page 74: Electrical CSR 12-13

12-3-64 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with, 415 V 50 cycles A. C., suitable for 30 to 90 LPM discharge at 105 to 50m head & (Max. effciency at 85m head 60 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 26027 1749.29 27776.00

12-3-65 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewellof required HP with-, 415 V 50 cycles A. C, suitable for 30 to 90 LPM discharge at 126 to 60m head & (Max. effciency at 102m head 60 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 27544 1749.29 29293.00

12-3-66 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with,415 V 50 cycles A. C., suitable for 85 to170 LPM discharge at 67 to 27 m head & (Max. effciency at 49 m head 130 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 24744 1749.29 26493.00

12-3-67 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewellof required HP with, 415 V 50 cycles A. C., suitable for 30 to 90 LPM discharge at 147 to 70 m head & (Max. effciency at 119m head 60 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 31068 1749.29 32817.00

12-3-68 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with, 415 V 50 cycles A.C., suitable for 30 to 90 LPM discharge at 168 to 80 m head & (Max. effciency at 136m head 60 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp. As per specification No. WP-SMP

Each 32689 1749.29 34438.00

12-3-69 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with, 415 V 50 cycles A.C., suitable for 85 to 170 LPM discharge at 88 to 36 m head & (Max. effciency at 68 m head 130 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp. As per specification No. WP-SMP

Each 27560 1749.29 29309.00

12-3-70 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with,415 V 50 cycles A.C., suitable for 85 to 170 LPM discharge at 110 to 46 m head & (Max. effciency at 83 m head 130 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 30489 1749.29 32238.00

12-3-71 Supplying and erecting submersible pumpset suitable for 100 mm dia. borewell of required HP with ,415 V 50 cycles A.C., suitable for 85 to 170 LPM discharge at 133 to 55 m head & (Max. effciency at 100 m head 130 LPM discharge ) & delivery pipe of necessary diameter with a necessary H. type clamp as per specification No. WP-SMP

Each 32601 1749.29 34350.00

Note :- Preferably energy efficient motors with p.f above 0.9 shall be used.

12.4 Submersible pumps for Open well (OSP) 12-4-1 Supplying and erecting submersible pump set suitable for erection on

open well of required HP with 415 V 50 c/s.A.C. supply, having delivery head from 21 to 7 m and discharge from 200 to 800 Itrs. per minute (Max efficiency at 16 m head & 500 Itr discharge) & delivery pipe of necessary diameter erected with necessary H type clamps as per specification No. WP-OSP

Each 16611 1749.29 18360.00

12-4-2 Supplying and erecting submersible pump set suitable for erection on open well --do--,. pump having delivery head from 24 to 13m. and discharge from 400 to 1000 Itrs. per minute (Max efficiency at 21m head & 680 Itr discharge) & delivery pipe of necessary diameterline erected with necessary H type clamps as per specification No. WP-OSP

Each 18559 1749.29 20308.00

12-4-3 Supplying and erecting submersible pump set suitable for erection on open well --do--, . pump having delivery head from 20 to 10m and discharge from 450 to 1600 Itrs. per minute (Max efficiency at 17 m head & 1250 Itr discharge) & delivery pipe of necessary diameter erected with necessary H type clamps as per specification No. WP-OSP

Each 28625 1749.29 30374.00

12-4-4 Supplying and erecting submersible pump set suitable for erection on open well --do--, pump having delivery head from 36 to 18 m and discharge from 400 to 1000 Itrs. per minute (Max efficiency at 29 m head & 680 Itr discharge) & delivery pipe of necessary diameter erected with necessary H type clamps as per specification No. WP-OSP

Each 28181 1749.29 29930.00

12-4-5 (New)

Supplying and erecting 1 phase, 230 V, 50 Hz, submersible pump set suitable for erection on open well, pump having discharge 35 / 270 L.P.M., head 30 / 15 m & delivery pipe of necessary diameter erected with necessary H type clamps as per specification No. WP-OSP

Each 15448 1749.29 17197.00

12-4-6 (New)

Supplying and erecting 1 phase, 230 V, 50 Hz, submersible pump set suitable for erection on open well , pump having discharge 130 / 475 L.P.M., head 21 / 9 m & delivery pipe of necessary diameter erected with necessary H type clamps as per specification No. WP-OSP

Each 16325 1749.29 18074.00

Page 75: Electrical CSR 12-13

Note :- 1) Preferably energy efficient motors with p.f above 0.9 shall be used.

12.5 Accessories 12-5-1 Supplying and erecting D.O.L. Starter 400V. 3 phase, 50 cycles with no

volt coil and overload element with necessary materials and connected to supply upto 10 H.P.

Each 1755 61.23 1816.00

12-5-2 Supplying and erecting D. O. L. Starter suitable for 250V. single phase, 50 cycleswith overload element with necessarymaterials and connected to supply upto 2 H.P.

Each 1072 54.9 1127.00

12-5-3 Supplying and erecting hand operated star/delta starter suitable for 7.5 H.P. to 12.5 H.P. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame.

Each 5298 123.52 5422.00

12-5-4 Supplying and erecting fully Automatic star/delta starter suitable for 10 H.P. to 12.5 H.P. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame. (similar to L & T make MK-1 FASD model.)

Each 6543 123.52 6667.00

12-5-5 Supplying and erecting fully Automatic star/delta starter suitable for 15.0 H.P. to 25 H.P. squirrel cage motor totally enclosed with overload and no volt relay completeerected on provided angle iron frame.(Similar to L & T make ML-1.5 FASDModel)

Each 9809 123.52 9933.00

12-5-6 Supplying and erecting fully Automatic star / delta starter suitable for above 25 H. P. to 35 H. P. squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame. (similar to L & T make MK-2 FASD model.)

Each 16707 123.52 16831.00

12-5-7. Supplying & erecting directly operated single phasing preventor omp[lete erected to supply to operate in case of single phaseing with guarantee for mi9nimum one Year.

Each 3872 123.52 3996.00

12-5-8 Supplying and erecting flat flexible 3 core 2.5 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.

Mtr. 56 13.72 70.00

12-5-9 Supplying and erecting flat flexible 3 core 4 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.

Mtr. 83 13.72 97.00

12-5-10 Supplying and erecting flat flexible 3 core 6 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.

Mtr. 116 13.72 130.00

12-5-11 Supplying and erecting flat flexible 3 core 1.5 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.

Mtr. 36 13.72 50.00

12-5-12 Supplying and erecting cover for motor made from G.I. sheet of 1.25mm (18 SWG) for protection from rain complete with collar at bottom & strengthening with M.S. strip, handle at top for lifting & drip proof louvers for ventilation erected at the position. (size to be specified in sq. m.)

Sqm. 1320 278.7 1599.00

12-5-13 Supplying and erecting single pole 250V or double pole 500 V 10 A float switch with 2m chain with adjustable stop counter weight float with necessary materials in position, complete

Each 4515 149.91 4665.00

12-5-14 Supplying & erecting Water lavel controller 230/415 V AC., Two way for under ground tank operation only.

Each 3892 197.42 4089.00

12-5-15 Supplying & erecting Water lavel controller 230/ 415V AC., Four way for under ground & Over head tank operation .

Each 4351 197.42 4548.00

12-5-16 Supplying & erecting PVC coated 5 mm dia Brass Sensor/ electrode duly wired with nut & bolts complete

Each 167 48.56 216.00

12-5-17 Supplying & erecting automatic control panel for 1 to 6 HP centrifugal/ submersible pump set consisting of DOL starter, S.P.P., Water level controller, ammeter, voltmeter, phase indicating lamp etc. 2 way for U/G tank.

Each 8673 197.42 8870.00

12-5-18 Supplying & erecting automatic control panel for 1 to 6 HP centrifugal/ submersible pump set consisting of DOL starter, S.P.P., Water level controller, ammeter, voltmeter, phase indicating lamp etc. 4 way for U/G tank.& OH tank.

Each 9374 197.42 9571.00

12-5-19 Supplying & erecting automatic control panel for 7 to 10 HP centrifugal/ submersible pump set consisting of DOL starter,S.P.P., Water level controller , ammeter, voltmeter, phase indicating lamp etc. 2 way for U/G tank.

Each 9433 197.42 9630.00

12-5-20 Supplying & erecting automatic control panel for 7 to 10 HP centrifugal/ submersible pump set consisting of DOL starter,S.P.P., Water level controller , ammeter, voltmeter, phase indicating lamp etc. 4 way for U/G tank.& OH tank.

Each 10192 197.42 10389.00

12-5-21 Supplying & erecting automatic control panel for 11to15 HP centrifugal/ submersible pump set consisting of star delta starter,S.P.P., Water level controller , ammeter, voltmeter, phase indicating lamp etc. 2 way for U/G tank.

Each 20588 197.42 20785.00

Page 76: Electrical CSR 12-13

12-5-22 Supplying & erecting automatic control panel for 11 to 15 HP centrifugal/ submersible pump set consisting of star delta starter,S.P.P., Water level controller , ammeter, voltmeter, phase indicating lamp etc. 4 way for U/G tank.& OH tank.

Each 22759 197.42 22956.00

Note :- For single phase pump panel, reduce overall rate by 50%

12.6 Dismantling 12-6-1 Dismantling the existing water pump set centrifugal type without

pipeline complete and making the site clear. HP 0 47.51 48.00

12--6-2 Dismantling the existing ejecto type water pump set without pipeline complete and making the site clear.

HP 0 47.51 48.00

12-6-3 Dismantling the existing ejecto pump with PVC pipeline. Each 0 614.42 614.00 12--6-4 Dismantling the existing ejecto pump with GI pipeline upto 10 m depth. Each 0 1228.83 1229.00 12-6-5 Dismantling the existing submersible pump with PVC pipeline. Each 0 614.42 614.00 12-6-6 Dismantling the existing submersible pump with GI pipeline upto 10 m

depth. (For additional depth of each 3 mtrs or part thereof add Rs.50/- per 3 meter, in the rates)

Each 0 1228.83 1229.00

Chapter 13 : FIRE FIGHTING & FIRE ALARM (FF) 13.1 Main Fire Pumps (Single Stage Centrifugal) (MFP/SSC)

13-1-1 Supplying and installing, testing, perfect aligning and proper leveling and commissioning of fire service main pump, of 1400 LPM (Litres/min.) at 56m centrifugal type single stage pump of 30 HP, (22 kW) with Suction / Delivery size of 80 / 65 mm as per specification No. FF- MFP/SSC

Each 113966 6751.2 120717.00

13-1-2 Supplying and installing, testing, perfect aligning and proper leveling and commissioning of fire service main pump, of 1800 LPM (Litres/min.) at 76 m head centrifugal type single stage pump, 50 HP, (37 kW) Suction / Delivery size of, 80 / 65 mm as per specification No. FF- MFP/SSC

Each 179233 6751.2 185984.00

13-1-3 Supplying and installing, testing, perfect aligning and proper leveling and commissioning of fire service main pump, of 2400 LPM (Litres/min.) at 76 m head centrifugal type single stage pump, 75 HP, (55 kW) Suction / Delivery size of 100 / 80 mm as per specification No. FF- MFP/SSC

Each 263187 8750.7 271938.00

13.2 Main Fire Pumps (Multi Stage Centrifugal) (MFP/MSC) 13-2-1 Supplying and installing, testing, perfect aligning and proper leveling

and commissioning of fire service main pump, multistage, of 2400 LPM (Litres/min.) at 88m head centrifugal type, 75 HP, (55 kW) Suction / Delivery size of125 / 100 mm as per specification No. FF-MFP/MSC

Each 261253 8750.7 270004.00

13-2-2 Supplying and installing, testing, perfect aligning and proper leveling and commissioning of fire service main pump, multistage, of 2800 LPM (Litres/min.) at 76m head centrifugal type, 75 HP, (55 kW) Suction / Delivery size of 125 / 100 mm as per specification No. FF-MFP/MSC

Each 313407 8750.7 322158.00

13-2-3 Supplying and installing, testing, perfect aligning and proper leveling and commissioning of fire service main pump, multistage, of 2800 LPM (Litres/min.) at 105m head centrifugal type, 120 HP, (90 kW) Suction / Delivery size of 150 / 125 mm as per specification No. FF-MFP/MSC

Each 364684 10626.68 375311.00

13.3 Main Fire Pumps (Submersible) (MFP/SBM) 13-3-1 Supplying, erecting, testing and commissioning of main Fire service

submercible Pump 2 stage of 1400 LPM at 56mtr Head and at 1400 RPM, 3Ph. 440V, 30 HP as per specification no. FF-MFP/SBM

Each 75806 2499.9 78306.00

13-3-2 Supplying, erecting, testing and commissioning of main Fire service submercible pump, 3 stage, 1800 LPM at 76m head, 45HP as per specification No. FF-MFP/SBM

Each 110846 2499.9 113346.00

13-3-3 Supplying, erecting, testing and commissioning of main Fire service submercible pump , 5 stage, 2400 LPM at 88 m head, 75HP as per specification No. FF-MFP/SBM

Each 157300 3756.18 161056.00

13-3-4 Supplying, erecting, testing and commissioning of main Fire service submercible pump, 2 stage, 1800 LPM at 56m head, 30HP as per specification No. FF-MFP/SBM

Each 98762 2499.9 101262.00

13-3-5 Supplying, erecting, testing and commissioning of main Fire service submercible pump, 7 stage, 2800 LPM at 105m head, 105HP as per specification No. FF-MFP/SBM

Each 215684 3756.18 219440.00

13-3-6 Supplying, erecting, testing and commissioning of main Fire service service submercible Pump 4 stage 280 LPM at 76m Head 60 HP as per specification No. FF-MFP/SBM

Each 130904 2499.9 133404.00

13.4 Jockey Pumps (Centrifugal) (MFP/JP)

Page 77: Electrical CSR 12-13

13-4-1 Supplying installing, testing, commissioning of Jockey Pump of 240 LPM at 56 m head, 3 ph. 440 A.C.15 HP, (11 kW) Suction / Delivery Size 50/32 mm as per specification No. FF-MFP/JP

Each 38027 963.85 38991.00

13-4-2 Supplying installing, testing, commissioning of Jockey Pump of 240 LPM at 105 mtr. head 3 ph. 440 A.C., 20 HP (18.5 kW) Suction / Delivery Size 50/32 mm as per specification No. FF-MFP/JP

Each 75900 1375.58 77276.00

Jockey Pumps (Submercible type) 13-4-3 Supplying installing, testing, commissioning of Jockey Pump

Submercible type, 4 stage, 240 LPM at 56m head, 7.5HP as per specification No. FF-MFP/JP

Each 37327 624.97 37952.00

13-4-4 Supplying installing, testing, commissioning of Jockey Pump Submercible type, submercible pump, 6 stage, 240 LPM at 105m head, 10HP as per specification No. FF-MFP/JP

Each 62016 750.6 62767.00

13.5 Booster Pump (MFP/BP) 13-5-1 Supplying installing, testing, commissioning of Booster Pump of 450

LPM at 35 m head single stage (mono block) 3 ph. 440 A.C. 7.5 HP Suction / Delivery Size 50/32 mm as per specification No. FF-MFP/BP

Each 22354 854.06 23208.00

13-5-2 Supplying installing, testing, commissioning of Booster Pump of 468 LPM at 40m head ,10 HP Suction / Delivery Size 50/32 mm as per specification No. FF-MFP/BP

Each 28923 908.96 29832.00

13.6 Pipes (PP) 13-6-1 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of size

20 mm dia with necessary fittings as per specification No. FF-PPMtr. 126 27.45 153.00

13-6-2 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of size 25 mm dia with necessary fittings as per specification no. FF-PP

Mtr. 171 27.45 198.00

13-6-3 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of size 50 mm dia with necessary fittings as per specification No. FF-PP

Mtr. 321 27.45 348.00

13-6-4 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of size 75/80 mm dia with necessary fittings as per specification No. FF-PP

Mtr. 524 41.17 565.00

13-6-5 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of size 100 mm dia with necessary fittings as per specification no. FF-PP

Mtr. 756 41.17 797.00

13-6-6 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of size 150 mm dia with necessary fittings as per specification no. FF-PP

Mtr. 1122 41.17 1163.00

13-6-7 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of size 200 mm dia with necessary fittings as per specification no. FF-PP

Mtr. 1910 68.62 1979.00

Note :- In case of laying underground pipes, add 20 % in the above overall rates, for excavation and anti-corrosive protections.

13.7 Valves (VL) Foot Valve (FV)

13-7-1 Supplying and installing cast iron foot valve of size 75/80 mm dia with strainer for negative suction as per specification No. FF-VL/FV

Each 4818 137.24 4955.00

13-7-2 Supplying and installing cast iron foot valve of size 100 mm dia with strainer for negative suction as per specification No. FF-VL/FV

Each 6150 137.24 6287.00

13-7-3 Supplying and installing cast iron foot valve of size 150 mm dia with strainer for negative suction as per specification No. FF-VL/FV

Each 13260 205.86 13466.00

13-7-4 Supplying and installing cast iron foot valve of size 200 mm dia with strainer for negative suction as per specification No. FF-VL/FV

Each 13910 276.59 14187.00

End Line Strainer (+ve suction) (ELS) 13-7-5 Supplying and installing 75/80 mm dia end line strainer for +ve suction

as per specification No. FF-VL/ELSEach 2231 157.3 2388.00

13-7-6 Supplying and installing 100 mm dia end line strainer for +ve suction as per specification No. FF-VL/ELS

Each 3126 157.3 3283.00

13-7-7 Supplying and installing 150 mm dia end line strainer for +ve suction as per specification No. FF-VL/ELS

Each 6089 315.65 6405.00

13-7-8 Supplying and installing 200 mm dia end line strainer for +ve suction as per specification No. FF-VL/ELS

Each 10683 315.65 10999.00

Sluice Valve 13-7-9 Supplying and installing cast iron double flange sluice valve 75/80 mm

dia.as per specification No. FF-VL/SVEach 4034 157.3 4191.00

13-7-10 Supplying and installing cast iron double flange sluice valve 100 mm dia. as per specification No. FF-VL/SV

Each 5351 157.3 5508.00

13-7-11 Supplying and installing cast iron double flange sluice valve 150 mm dia. as per specification No. FF-VL/SV

Each 7820 315.65 8136.00

13-7-12 Supplying and installing cast iron double flange sluice valve 200 mm dia.as per specification No. FF-VL/SV

Each 14316 315.65 14632.00

Butterfly Valves (BFV) 13-7-13 Supplying & Installing cast iron double flange butterfly valve of size 75/80

mm dia. as per specification No. FF-VL/BFVEach 1741 157.3 1898.00

13-7-14 Supplying & Installing cast iron double flange butterfly valve of size 100 mm dia. as per specification No. FF-VL/BFV

Each 1991 157.3 2148.00

Page 78: Electrical CSR 12-13

13-7-15 Supplying & Installing cast iron double flange butterfly valve of size 150 mm dia. as per specification No. FF-VL/BFV

Each 3496 157.3 3653.00

13-7-16 Supplying & Installing cast iron double flange butterfly valve of size 200 mm dia.as per specification No. FF-VL/BFV

Each 5493 157.3 5650.00

Non Return Valves (NRV) 13-7-17 Supplying and installing double flange NRV of size 75/80 mm dia as per

specification No. FF-VL/NRVEach 3657 157.3 3814.00

13-7-18 Supplying and installing double flange NRV of size 100 mm dia as per specification No. FF-VL/NRV

Each 4921 157.3 5078.00

13-7-19 Supplying and installing double flange NRV of size 150 mm dia as per specification No. FF-VL/NRV

Each 8401 315.65 8717.00

13-7-20 Supplying and installing double flange NRV of size 200 mm dia as per specification No. FF-VL/NRV

Each 13775 315.65 14091.00

Gate / Wheel Valves (GV) 13-7-21 Supplying & installing gun metal gate valve of size 20/25mm dia as

per specification No. FF-VL/GVEach 514 68.62 583.00

13-7-22 Supplying & installing gun metal gate valve of size 50 mm dia as per specification no. FF-VL/GV

Each 818 68.62 887.00

Hydrant Valves (HV) 13-7-23 Supplying and installing gun metal single outlet hydrant valve fitted with

necessary accessories complete as per specification No. FF-VL/HVEach 7305 142.52 7448.00

13-7-24 Supplying and installing gun metal Double outlet hydrant valve fitted with necessary accessories complete as per specification No. FF-VL/HV

Each 22669 142.52 22812.00

13.8 Fire Fighting Accessories (FFA) Priming Tank

13-8-1 Supplying & installing One piece moulded HDP / Fibre water tank. for -ve suction only, having capacity 1000 ltrs.fitted with necessary accessories complete as per specification No. FF-FFA/PT

Each 11644 2148.35 13792.00

Hose Reel with Drum (HR) 13-8-2 Supplying and installing wall mounting swinging Hose reel drum fitted with

19 mm dia 22.5m long high pressure polypropylene (Polyhose) pipe fitted with necessary accessories complete as per specification No. FF-FFA/HRD

Each 5757 142.52 5900.00

13-8-3 Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m high pressure polypropylene (Polyhose) long fitted with necessary accessories complete as per specification No. FF-FFA/HV

Each 5690 124.57 5815.00

13-8-4 Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia 36m long high pressure polypropylene (Polyhose) pipe fitted with necessary accessories complete as per specification No. FF-FFA/HV

Each 8992 142.52 9135.00

Hose Pipes 13-8-5 Supplying fire fighting C.P. (controlled percolation) Hose pipe, 63mm dia,

15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/CPH

Each 2873 0 2873.00

13-8-6 Supplying fire fighting R.R.L. Hose pipe, 63mm dia,15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL

Each 3042 0 3042.00

13-8-7 Supplying fire fighting Flax canvas Hose pipe, 63 MM dia,15 mtr. in length, fitted with necessary accessories complete as per specification no. FF-FFA/CHP

Each 5978 0 5978.00

13-8-8 Supplying & erecting high pressure polypropylene hose pipe 63 mm dia,19 mm dia.complete as per specification No. FF-FFA/HOP

Mtr. 144 1.06 145.00

13-8-9 Supplying & erecting high pressure rubber hose pipe 19 mm dia complete as per specification no. FF-FFA/RHP

Mtr. 104 1.06 105.00

Nozzles (NZ) 13-8-10 Supplying G.M. branch pipe of 63 mm Ø fitted with 20 mm Ø detachable

hexagonal nozzle as per specification No. FF-FFA/NZEach 2579 0 2579.00

13-8-11 Supplying & erecting Gun Metal Chrome plated Nozzle, 19 mm Ø complete as per specification No. FF-FFA/NZ

Each 878 0 878.00

Fire Brigade Connection (FBC) 13-8-12 Supplying and installing fire brigade Header of 150 mm Ø, for supplying

water in fire tank as per specification No. FF-FA/FBCEach 6414 187.91 6602.00

Siamese Connection (SMC) 13-8-13 Supplying and installing fire brigade Header (Siamese Connection) of 150

mm Ø for supplying water to wet riser system as per specification No. FF- FFA/SMC

Each 10594 187.91 10782.00

Air Cushion Tank (Air Vessel) (ACT) 13-8-14 Supplying and installing Air Vessel of 300 mm Ø 1.5m in height M.S.

tank installed inside pump house as per specification No. FF-FFA/ACTEach 11071 250.2 11321.00

Air Release Valve (ARV) 13-8-15 Supplying and erecting 20/25mm Ø G.M.air release cock, with

necessary G.I. coupling to be fitted on top of Air vessel or on wet riser as per specification No. FF-FFA/ARV

Each 479 31.67 511.00

Pressure Guage (PG)

Page 79: Electrical CSR 12-13

13-8-16 Supplying and installing pressure gauge of 100 mm Ø., 0-300 PSI or 0-21 kg per cm square fitted with 12/15 mm Ø. pad cock valve, and G.I. pipe, elbow etc. as per requirement in an approved manner as per specification No. FF-FFA/PG

Each 712 35.89 748.00

Pressure Switch (PS) 13-8-17 Supplying and installing DANFOSS make pressure switch with 12/15 mm

Ø isolation valve, G.I. nipple, elbow etc. in an approved manner as per specification No. FF-FFA/PS

Each 1507 49.62 1557.00

Orifice Plate (OP) 13-8-18 Supplying and erecting one no. Brass orifice plate having 6 mm. thickness,

140 mm outer dia of 140 mm at every single outlet hydrant valve as per specification No. FF-FFA/OP

Each 630 38.01 668.00

13-8-19 Supplying and erecting one no. Brass orifice plate having 6 mm thickness, 160 mm outer dia at every double outlet hydrant valve as per specification No. FF-FFA/OP

Each 710 49.62 760.00

MS / CRCA Boxes (BOX) 13-8-20 Supplying and erecting M.S./CRCA cabinet for housing single hydrant

valve (size 400 x 400 x 400mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.

Each 3278 187.91 3466.00

13-8-21 Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.

Each 5430 187.91 5618.00

13-8-22 Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 mm. x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.

Each 11236 250.2 11486.00

13.9 Fire Alarm System (FAS) 13-9-1 Supplying and erecting testing heat detector complete on box as per

specification no. FF-FAS/HDEach 1499 124.57 1624.00

13-9-2 Supplying, erecting and testing optical type smoke detector complete on box as per specification No. FF-FAS/SD

Each 1421 124.57 1546.00

13-9-3 Supplying & Erecting four wire conventionally single ended reflected type beam smoke detector with 8 “ receiver . The range of smoke detector is max 325 feet.

Each 34000 1249.95 35250.00

Note :- For large areas and passages beam detectors should be prefebraly used (Item No. 13-9-3)

13.10 Fire Alarm Accessories (FAAS) 13-10-1 Supplying, erecting, testing and commissioning Manual Call Point (Pill

box) with break glass push button in metal enclosure complete as per specification No. FF-FAAS/MCP

Each 299 124.57 424.00

13-10-2 Supply and erecting hooters with CRCA enclosure complete as per specification No. FF-FAAS/HTR

Each 351 124.57 476.00

13-10-3 Supplying, erecting and testing remote response indicators as per specification No. FF-FAAS/RRI

Each 111 62.29 173.00

13-10-4 Supplying and erecting PVC armoured cable 2 core 1.5 sq.mm. FRLS copper conductor complete erected on wall/ ceiling as per specification No. CB-LT/CU

Mtr. 41 5.28 46.00

13-10-5 Supplying and erecting PVC armoured cable 4 core 1.5 sq.mm. FRLS copper complete erected on wall/ ceiling as per specification No. CB-LT/CU

Mtr. 49 7.39 56.00

13-10-6 Supplying and erecting PVC armoured cable 8 core 1.5 sq.mm. FRLS copper complete erected on wall/ ceiling as per specification No. CB-LT/CU

Mtr. 70 11.61 82.00

13-10-7 Supplying and erecting PVC armoured cable 12 core 1.5 sq.mm. FRLS copper complete erected on wall/ ceiling as per specification No. CB-LT/CU

Mtr. 89 13.72 103.00

13-10-8 Supply and erecting two core 1.5 mm sq. Mineral Insulated copper cable with an overall (LSF) covering. 500 Volt. To withstand temp. 950 Deg C for period of 3 hrs., Mechanical shock and High Pressure water stream used during the fire fighting as per specification no FF-FAAS/MIC

Mtr. 518 25.34 543.00

13-10-9 Supply and erecting two core 2.5 mm sq. Mineral Insulated copper cable with an overall (LSF) covering. 500 Volt. To withstand temp. 950 Deg C for period of 3 hrs., Mechanical shock and High Pressure water stream used during the fire fighting as per specification no FF-FAAS/MIC

Mtr. 702 25.34 727.00

Page 80: Electrical CSR 12-13

13-10-10 Supply and erecting seven core 1.5 mm sq. Mineral Insulated copper cable with an overall (LSF) covering. 750 Volt. To withstand temp. 950 Deg C for period of 3 hrs., Mechanical shock and High Pressure water stream used during the fire fighting as per specification no FF-FAAS/MIC

Mtr. 1490 49.62 1540.00

13-10-11 Supply and erecting Gland and Plain Seals suitable for 2 Core 1.5 mm sq. Mineral Insulated copper cable as per specification no FF-FAAS/MIC

Each 566 31.67 598.00

13-10-12 Supply and erecting Gland and Plain Seals suitable for 2 Core 2.5 mm sq. Mineral Insulated copper cable as per specification no FF-FAAS/MIC

Each 566 31.67 598.00

13-10-13 Supply and erecting Gland and Plain Seals suitable for 7 Core 1.5 mm sq. Mineral Insulated copper cable as per specification no FF-FAAS/MIC

Each 2690 31.67 2722.00

Note :- 1) Item no 13-10-8 to 13-10-13 shall be utilised only for original work with prior permission from Chief Engineer (Electrical) 2) Mineral Insulated Copper Cable (A heavy duty grade with a voltage rating of 1000 volt - BS 6207:Part 1:1969) other than above three category up to 16 sq. mm shall be preferably used in hazardous places like basement and Mezzanine floor for all utility services in Govt installation

13-10-12 Supplying, erecting, testing and commissioning the 2 Zones Microprocessor based conventional Fire Alarm Control Panel (FACP) with standard accessories complete as per specification No. FF- FAAS/FACP

Each 11150 624.97 11775.00

Note :- Increase over all rate by 25 % for additional zone as per requirement. 13-10-13 Supplying, erecting, testing and commissioning 2 Zone, local signal

control panel (LCP) with standard accessories complete as per specification No. FF-FAAS/LCP

Each 5200 124.57 5325.00

Note :- Increase over all rate by 10 % for additional zone as per requirement.13-10-14 Supplying, erecting , testing & commissioning the 2 Zones Microprocessor based

conventional fire alarm control panel (FACP) with standard accessories complete as per specification No.FF-FAAS/FACP.

Each 11150 624.974411775

Note :- Increase over all rate by 25% for additional Zone as per requirement.13-10-15 Supplying, erecting , testing & commissioning the 2 Zones, local control panel (LCP)

with standard accessories complete as per specification No. FF-FAAS/LCP.

Each 5200 124.57265325

Note :- Increase over all rate by 10% for additional Zone as per requirement.

13.11 P A System (PAS) 13-11-1 Supplying, erecting, testing and commissioning amplifier 120 W for

Public address system suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply as per specification No. FF-PA/AFR

Each 11473 78.12 11551.00

13-11-2 Supplying, erecting, testing and commissioning sound column 15 Watts complete as per specification No. FF-PA/SOC

Each 1722 40.12 1762.00

13-11-3 Supplying, erecting, testing and commissioning microphone as per specification No. FF-PA/MIC

Each 3046 78.12 3124.00

13-11-4 Supplying & erecting, stand for microphone. (Similar to AHUJA make model DGN)

Each 1209 40.12 1249.00

13-11-5 Supplying & erecting, Table stand for microphone. (Similar to AHUJA make model DGT)

Each 723 40.12 763.00

13-11-6 Supplying erecting, testing to 2 core shielded Microphone cable as per specification No. FF-PA/MCC

Mtr. 132 5.28 137.00

13.12 Sprinklers (SPR) 13-12-1 Supplying and erecting 15 mm (1/2") dia. NBCM Body chrome finished

quartzoid bulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction as per specification No. FF-SPR

Each 410 142.52 553.00

13-12-2 Supplying & erecting vane type water flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines of 75/80 mm dia having following features 1) Visual Switch Activation 2) Rugged Switch Assembly 3) Heavy Duty Alluminium pipe Saddles 4) Durable Metal Encloser 5) Steel U Bolts For Secure Mounting 6) Two SPDT ( Single Pole Double Track ) Synchronised Switches 7) Serviceable Without Draining Pipes

Each 6623 142.52 6766.00

13-12-3 Supplying & erecting vane type water flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines of 100 mm dia having following features 1) Visual Switch Activation 2) Rugged Switch Assembly 3) Heavy Duty Alluminium pipe Saddles 4) Durable Metal Encloser 5) Steel U Bolts For Secure Mounting 6) Two SPDT ( Single Pole Double Track ) Synchronised Switches 7) Serviceable Without Draining Pipes

Each 7589 142.52 7732.00

Chapter 14 : TEMPORARY ILLUMINATION (TE - IL) 14.1 Temporary Illumination (TE-IL) Unit

Page 81: Electrical CSR 12-13

14-1-1 Temporary illumination consisting of strip lights consist of 50 bulbs 25W each in strip complete with holders, bulbs of required Wattage mains, Switchgears erected and dismantled without using scaffolding and maintaining the same upto three days.

Each 24 8.45 32.00

14-1-2 Temporary illumination consisting of strip lights consist of 50 bulbs 25W each in strip complete with holders, bulbs of required Wattage mains, Switchgears erected and dismantled, with using scaffolding and maintaining the same upto three days.

Each 24 14.78 39.00

14-1-3 Temporary illumination consisting of tube light day light & colour 4' X 40 Watts complete erected with tubes, mains and Switchgears with continuous earth wire erected and dismantled without using scaffolding upto three days.

Each 26 8.45 34.00

14-1-4 Temporary illumination consisting of tube light day light & colour 4' X 40 Watts complete erected with tubes, mains and Switchgears with continuous earth wire erected and dismantled, with using scaffolding upto three days.

Each 26 14.78 41.00

14-1-5 Temporary illumination consisting of flood light fitting 1000/500W. complete halogen fitting with lamp, holders, mains and Switchgears with continuous earth wire erected and dismantled without using scaffolding upto three days.

Each 149 29.56 179.00

14-1-6 Temporary illumination consisting of flood light 1000/500W. complete halogen fitting with lamp, holders, mains and Switchgears with continuous earth wire erected and dismantled, with scaffolding upto three days.

Each 149 38.01 187.00

14-1-7 Temporary illumination consisting of Metal Halide flood light fitting 250 W complete with lamp, holders, mains and Switchgears with continuous earth wire erected and dismantled without using scaffolding upto three days.

Each 163 29.56 193.00

14-1-8 Temporary illumination consisting of Metal Halide flood light fitting 250 W complete with lamp, holders, mains and Switchgears with continuous earth wire erected and dismantled, with using scaffolding upto three days.

Each 163 38.01 201.00

14-1-9 Temporary illumination consisting of Metal Halide flood light fitting 400 W complete with lamp, holders, mains and Switchgears with continuous earth wire erected and dismantled, without using scaffolding upto three days.

Each 166 29.56 196.00

14-1-10 Temporary illumination consisting of Metal Halide flood light fitting 400 W complete with lamp, holders, mains and Switchgears with continuous earth wire erected and dismantled, with using scaffolding upto three days.

Each 166 38.01 204.00

14-1-11 Temporary illumination consisting of white/colour series lights 50 Nos. with miniature lamps of 6.2 to 16V with holders, bulbs, mains and Switchgears erected and dismantled with rotor effect as approved without scaffolding upto three days.

Per

Thousa nd

729 172.08 901.00

14-1-12 Temporary illumination consisting of white/colour series lights 50 Nos. with miniature lamps of 6.2 to 16V with holders, bulbs, mains and Switchgears erected and dismantled with rotor effect as approved with scaffolding upto three days.

Per

Thousa nd

729 287.15 1016.00

14-1-13 Temporary illumination consisting of 2000W. sungun or colour tran light fitting complete with stand cutter & strainer alongwith mains, tube & Switchgears with continuous earth wire erected & dismantled without scaffolding upto three days.

Each 362 47.51 410.00

14-1-14 Providing & fixing rotating machine to give running effect to strips lights & miniature lights upto a load of 5000 W either mechanical cum electrical or electronics complete with mains & Switchgears with continuous earth wire and dismantling upto three days.

Each 332 47.51 380.00

14-1-15 Temporary illumination wrapping of coloured gelatin paper to 40 W, fluorescent tube light/500 W flood light fitting complete with rubber boards and dismantling upto three days.

Each 5 0 5.00

14-1-16 Providing oscillating type pedestal air circulators 600/900 mm., or air cooler connected with necessary mains, Switchgears with continuous earthing maintaining the same during the function & including dismantling upto three days.

Each 288 0 288.00

14-1-17 Providing oscillating type pedestal fan 16" (400 mm) or ceiling fan connected with necessary mains, Switchgears with continuous earthing maintaining the same during the function & including dismantling upto three days.

Each 133 0 133.00

14-1-18 Providing evaporator air cooler connected with necessary mains, Switchgears with continuous earthing maintaining the same during the function & including dismantling upto three days.

Each 362 0 362.00

14-1-19 Providing heavy duty Exhaust fan 18" or 24" connected with necessary mains, Switchgears with continuous earthing maintaining the same during the function and including dismantling for three days.

Each 362 31.67 394.00

14-1-20 Providing temporary plug point with 3 pin 6A/16A with necessary mains & Switchgears & continuous earth connection upto three days.

Each 16 9.5 26.00

Page 82: Electrical CSR 12-13

14-1-21 Providing 1.5 Ton capacity window Air conditioning unit complete with temporary frame and fabrication work and required material to achieve cooling temperature connected along with necessary mains, switchgear and continuous earthing maintaining the same during the function and including dismantling; for three days.

Each 2599 321.99 2921.00

14-1-22 Providing 280 liters capacity Refrigerator complete with M.S. stand if necessary connected with main switchgear and continuous earthing maintaining the same during the function and including dismantling; for three days.

Each 551 78.12 629.00

14-1-23 Providing 120/150 liter capacity water cooler with water filter (Candle type or UV tube) with M.S. stand complete with minor plumbing work if necessary connected with mains switchgear and continuous earthing maintaining the same during the function and including dismantling; for three days.

Each 1028 314.6 1343.00

14-1-24 Providing 20"/24" colour Television with multi channel tuner, connected with necessary mains switchgear with continuous earthing maintaining the same during the function and including dismantling; for three days.

Each 346 0 346.00

14-1-25 Providing 6V/10V with 20/40 Watt fluorescent emergency lamp connected with necessary mains switchgear and continuous earthing maintaining the same during the function and including dismantling; for three days.

Each 132 0 132.00

14-1-26 Providing Digital projector with spring loaded white screen connected with necessary mains, switchgear and maintaining the same during the function including dismantling.

Each 5000 0 5000.00

14-1-27 (New)

Temporary illumination consisting of Round LED / neon flex LED / flexible strip LED having 2 to 5 W capacity per meter and consisting suitable power adaptor with mains, Switchgears erected and dismantled without using scaffolding and maintaining the same upto three days.

Mtr. 7 2.11 9.00

14-1-28 (New)

Temporary illumination consisting of Round LED / neon flex LED / flexible strip LED having 2 to 5 W capacity per meter and consisting suitable power adaptor with mains, Switchgears erected and dismantled with using scaffolding and maintaining the same upto three days.

Mtr. 7 3.17 10.00

Note :- 1) Rates for item no 15.1.1 to 15.1.15 are for period of 3 days function which includes prepatory period with testing if any required and transportation. 2) For item no 15.1.16 to 15.1.25 the rates are for period of 3 days function which includes prepatory period with testing and connecting, commissioning & maintaining in healthy condition with transportation. 3) For each additional day after 3 days but not exceeding 15 days, add 25 % per day. 4) For additional (i.e. after for 3+15) days, add 5 % per day but total rental charge shall be limited to 80 % of full rate of completed item. 5)For item no 15.1.26 the rates of projector for 1 function or for max. period of 1 day whichever is more including transportation, connections with project operator till completion of function.

14.2 Hiring of Generators (TE-DG) 14-2-1 Rental charges for supplying & maintaining 440V, 50 cycles A. C.

generating set 125 kVA capacity with necessary fuel, mains Switchgears and accessories complete with continuous running on load/no load as per requirements with necessary certificate from Electrical Inspector.

Per Day

13114 573.25 13687.00

14-2-2 Rental charges for supplying & maintaining 440V, 50 cycles A. C. generating set 75 to 100 kVA capacity with necessary fuel, mains Switchgears and accessories complete with continuous running on load/no load as per requirements with necessary certificate from Electrical Inspector.

Per Day

10506 573.25 11079.00

14-2-3 Rental charges for supplying & maintaining 440V, 50 cycles A. C. generating set 50/62.5 kVA capacity with necessary fuel, mains Switchgears and accessories complete with continuous running on load/no load as per requirements with necessary certificate from Electrical Inspector.

Per Day

8351 573.25 8924.00

14-2-4 Rental charges for supplying & maintaining 440V, 50 cycles A. C. generating set 25 to 40 kVA capacity with necessary fuel, mains Switchgears and accessories complete with continuous running on load/no load as per requirements with necessary certificate from Electrical Inspector.

Per Day

5803 573.25 6376.00

14-2-5 Rental charges for supplying & maintaining 440V, 50 cycles A. C. generating set 11 to 25 kVA (excluding 25 kVA) capacity with necessary fuel, mains Switchgears and accessories complete with continuous running on load/no load as per requirements with necessary certificate from Electrical Inspector.

Per Day

5357 429.67 5787.00

14-2-6 Rental charges for supplying & maintaining 230/440 V, 50 cycles A.C. generating set 3 to 10 kVA capacity with necessary fuel, mains Switchgears and accessories complete with continuous running on load/no load as per requirements with necessary certificate from Electrical Inspector..

Per Day

3575 287.15 3862.00

Page 83: Electrical CSR 12-13

14-2-7 Rental charges for supplying & maintaining 230V, 50 cycles A. C. generating set 1 to 2 kVA capacity with necessary fuel, mains Switchgears and accessories complete with continuous running on load/no load as per requirements with necessary certificate from Electrical Inspector.

Per Day

1597 142.52 1740.00

Note :- 1) Above rates are applicable for First day. For subsequent five days, the above rates shall be reduced by 10 %. 2) The rates of I No. 15-2-1 to 15-2-7 does not include transportation. 3) The above rates does not include preparatory & testing period, and no additional amount shall be paid for that. 4) The above rates are for function with on load working of DG Set upto 5 hours per day, and if, the DG Set is to be used continuously on load,or for more than five days this item shall not be operated. 5)The above rates are only for function purpose

Chapter 15 : SIREN (SRN) 15.1 Siren & Accessories (SRN)

15-1-1 Supplying and erecting weather shade for covering siren motor, made of 1.25mm (18 SWG) M.S sheet / PVC/ FRP sheet duly painted as per specification No. SRN-AS/WS

Each 4019 498.29 4517.00

Note :- Add Rs 675/- if painted with special thinner and epoxy paint. 15-1-2 Dismantling the existing Siren motor from the location lowering from

terrace to ground and loading and unloading for workshop.Each 0 427.56 428.00

15-1-3 Transportation of siren motor from site to workshop and back. (For Municipal Corporation Area Only)

Per Km.

0 35.89 36.00

15-1-4 Re-erecting the siren motor duly lifting at site and connected with assembly of existing siren by proper alignment, testing and giving test trial as original

Each 0 491.96 492.00

15-1-5 Scrapping the existing paint of outer surface, cleaning the surface & applying two coats of epoxy air dry paint (anticorrosive) of approved colour mixed in special type thinner complete. As per specification No. SRN- AS/PTG

Each 814 191.08 1005.00

15-1-6 Supplying and fixing superior quality metallastic antivibration rubber mounting to Siren.

Each 415 15.84 431.00

15-1-7 Deleted 15-1-8 Replacing the existing unservicable worn-out bearing by new ‘SKF’

bearings for heavy duty Siren motor.Each 634 76.01 710.00

15-1-9 Scrapping existing paint of Siren motor, blower and iron foundation completely and painting the same by one coat of red oxide and two coats of approved color superior quality epoxy paint.

Each 362 126.68 489.00

15-1-10 Supplying & erecting of 8 km. range Siren 440 Volts 3 phase horizontal double mounting type 5 H.P. 2800 RPM 50 cycles A.C. with adjustable foundation. As per specification no. SRN-AS/SM

Each 50564 555.3 51119.00

15-1-11 Supplying & erecting of 3.25 km range Siren single phase 220/250 Volts Horizontal double mounting type 1/2 HP 6000 RPM 50 cycles A.C. complete with adjustable foundation. As per specification no. SRN-AS/SM

Each 11591 555.3 12146.00

15-1-12 Providing in position C.C. foundation (1:2:4) with plastering for Siren motor of size 60 cms. X 60 cms. X 20 cm. with foundation nuts and bolts of required size & strength of the terrace of the building with 1.2 cm thick hard rubber sheet packing provided in between the foundation and motor base to minimise the jerks and vibration to the slab with teak wood frame etc.

Each 399 191.08 590.00

Chapter 16 : CIVIL WORK (CW) 16.1 Excavation (EXN)

16-1-1

Making trench in soft soil of suitable width and depth for laying provided L.T. cable up to 10sq.mm. complete.As per specification No. CW-EXN-CTR

44 35.89 80.00

16-1-2 Making the trench in Hard murum/Tar road of suitable width and depth for laying provided L.T cable up to 10 sq.mm.complete. As per specification No. CW-EXN-CTR

Mtr. 44 38.01 82.00

16-1-3 Making the trench in Hard murum/Tar road of suitable width and depth for laying provided L.T cable of 25 sq. mm & above and covered with Half round hume pipe complete. As per specification no. CW-EXN-CTR

Mtr. 130 116.13 246.00

16-1-4 Excavating hard Rock or bituminous road (B.T.) by chiseling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good.

Cum. 0 554.24 554.00

16-1-5 Excavating Hard Murum/metal road (B.T.) by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good.

Cum. 0 140.41 140.00

16-1-6 Excavating soft Murum/Soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good.

Cum. 0 131.96 132.00

Note :- 1) Add Rs. 20/- per meter for laying additional cable by the side in the same trench with additional bricks cover.

Page 84: Electrical CSR 12-13

2) For cables above 10 sq. mm bricks be laid on the cable width wise & overall rate shall be increased by 25%. In case of half round pipe is provided by making trench in soft soil reduce rate by Rs. 10.00 from overall rate of Item 17-1-3.

16.2 Masonry work 16-2-1 Providing transformer plinth 1.5 x 1.5 x 1.5 m in size with necessary

excavation in ground at the bottom with 150 mm. thick 1:2:4 cement concrete raft at the bottom and top and 225 mm. thick wall constructed in stone masanory and remaining hallow portion shall be filled in by 1:5:10 cement concrete, duly plastered 20 mm thick outside including watering etc. complete.

Each 5119 2671.98 7791.00

Note :- The above rates are for 1.2 meter height plinth (including 0.3 meter concrete for top & bottom) if excess height is required to maintain ground clearance as per IE Rule add Rs 300/- for 100 mm or part thereof.

16-2-2 Providing burnt brick masonry with 1:6 ratio cement concrete duly plastered including watering, streaking joint on exposed faces, rocking at joint on exposed faces and watering complete.

Cum. 1805 680.93 2486.00

16-2-3 Supplying & arranging properly burnt & necessary cured Bricks for varies purposes (Table size 9”x4.25”x3”) at work (100 Bricks)

cu.m 320 21.11 341.00

16-2-4 Providing and spreading stone metal 25mm size for 100 mm depth above the ground level.

Sqm. 85 5.28 90.00

16-2-5 Providing and spreading Screened Sand at site. cu.m 280 21.11 301.00 16-2-6 Supplying and erecting RCC chamber cover of size 750 mm x 750 mm x

50mm thick with lifting arrangment including laying of angle iron frame of angle size as 50 x 50 x6 mm to be fixed/embeded on top of chamber.

Each 1000 42.23 1042.00

16.3 C.C. Foundation 16-3-1 Providing cement concrete foundation including excavation for the poles

(45 cms. x 45 cms. x 1.2 Mtr.) deep in 1:3:6 cement concrete (20 to 25 mm stone metal) and 45 cm x 45 cm. x 45 cm./45 cm. dia. x 45 cm. height plinth duly plastered and with necessary curing and finishing in an approved manner. (for 6 m pole)

Each 854 176.3 1030.00

16-3-2 Providing cement concrete foundation including excavation for the poles 60 cms. x 60 cms. x 1.5 mtr. deep in 1:3:6 cement concrete (20 x 25 mm. stone metal) and 45 cm x 45 cm x 45 cm /45 cm. dia. x 45 cm. height plinth duly plastered and with necessary curing and finishing in an approved manner. (for 8.5 to 9 m poles)

Each 1669 344.16 2013.00

16-3-3 Providing cement concrete foundation including excavation for the poles 60 cms. x 60 cms. x 1.5 mtr. deep in 1:3:6 cement concrete (20 x 25 mm. stone metal) and 45 cm x 45 cm x 45 cm /45 cm. dia. x 45 cm. height plinth duly plastered and with necessary curing and finishing in an approved manner. (for above 9 m poles)

Each 1964 404.33 2368.00

16-3-4 Providing Cement concrete foundation for pump in 1:2:4 with required size and length of foundation bolts and nuts (cost with wooden box is included).

cu. mtr3246 577.47 3823.00

16-3-5 Providing C.C. foundation including excavation for stay 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20x25mm.stone metal) with necessary curing and finishing in an approved manner.

Each 1513 311.43 1824.00

16-3-6 Providing cement concrete for foundation or for concrete filling in 1:3:6 ratio with 20 to 25 mm. stone metal duly plastered with necessary curing for pole muffing or any other purposes.

Cum. 2801 577.47 3378.00

16-3-7 Designing & casting M- 20 cement concrete foundation suitable for 9 m octagonal pole considering the safe soil bearing capacity at site as 10 T/sq m at 2 meter depth including excavation, foundation nut bolts etc in an approved manner.

Each 12805 1725.01 14530.00

16-3-8 Designing & casting M- 20 cement concrete foundation suitable for 12.5 m high mast considering the safe soil bearing capacity at site as 10 T/sq m at 2 meter depth including excavation, foundation nut bolts etc in an approved manner.

Each 15852 2374.27 18226.00

16-3-9 Designing & casting M- 20 cement concrete foundation suitable for 16 m high mast considering the safe soil bearing capacity at site as 10 T/sq m at 2 meter depth including excavation, foundation nut bolts etc in an approved manner.

Each 25520 3815.3 29335.00

16-3-10 Designing & casting M- 20 cement concrete foundation suitable for 20 m high mast considering the safe soil bearing capacity at site as 10 T/sq m at 2 meter depth including excavation, foundation nut bolts etc in an approved manner.

Each 32911 5132.81 38044.00

Page 85: Electrical CSR 12-13

16-3-11 (New)

Designing and Casting M�20 cement concrete foundation suitable for Conical/Octagonal poles up to 6 m long considering the safe soil bearing capacity at site as T/sq m, at 1.2 m depth, including excavation, foundation nuts & bolts, etc., in approved manner.

Each 5705 703.1 6408.00

16-3-12 (New)

Designing and Casting M�20 cement concrete foundation suitable for Conical/Octagonal poles for 7 & 8 m long considering the safe soil bearing capacity at site as T/sq m, at 1.5 m depth, including excavation, foundation nuts & bolts, etc., in approved manner.

Each 7131 878.34 8009.00

16-3-13 (New)

Designing and Casting M�20 cement concrete foundation suitable for Conical/Octagonal poles for 10 to 12 m long considering the safe soil bearing capacity at site as T/sq m, at 2 m depth, including excavation, foundation nuts & bolts, etc., in approved manner.

Each 16950 2319.37 19269.00

Note :- Rate of c c foundation for Conical pole of 9 m long shall be as per rate of Item No 16-3-7

16.4 Painting (PTG) 16-4-1 Scrapping existing paint & Spray painting the table fan / pedestal fan /

cabin fan / ceiling fan / exhaust fan including guards etc As per specification No. CW-PTG/PTF

Each 66 34.84 101.00

16-4-2 Scrapping the existing paint and painting of pipe pole upto 6 m length along with street light / pole brackets / clamps completely as per specification No CW -PTG/PTP.

Mtr. 24 17.95 42.00

16-4-3 Scrapping the existing paint and painting of steel tubular / rail / RSJ pole above 6.0 m length along with street light / pole brackets / clamps completely as per specification No CW -PTG/PTP.

Mtr. 28 26.39 54.00

16-4-4 Scrapping existing paint & Spray painting of fluorescent fitting with flat reflector for 1x4' FTL completely. As per specification No. CW-PTG/PFT

Each 29 26.39 55.00

16-4-5 Scrapping existing paint & Spray painting of fluorescent fitting with flat reflector for 2x4' FTL completely. As per specification No. CW-PTG/PFT

Each 38 26.39 64.00

16-4-6 Spray Painting of Panel type lift doors of MS complete. As per specification no. CW-PTG/PLD1

Each 452 266.04 718.00

16-4-7 Painting lift door of collapsible type complete. As per specification No. CW-PTG/PLD2

Each 355 213.25 568.00

16-4-8 Spray painting of distribution transformer upto 200 kVA capacity complete. As per specification No. CW-PTG/PDT

Job 1449 746.38 2195.00

16-4-9 Spray painting of distribution transformer above 200 kVA capacity complete. As per specification No. CW-PTG/PDT

Job 2283 853.01 3136.00

16-4-10 Painting fencing of transformer sub station including all supports, iron work and doors from both sides with one coat of red oxide & two coats of aluminium paint, in an approved manner as per direction.(The square meter area of fencing shall be considered for measurement purpose.)

Per sqm of fencing

79 26.39 105.00

16-4-11 Scrapping existing paint of feeder pillar / switchgears (only outside) and frame of panel board completely without damaging and painting the same with single coat of Red oxide & two coats of apporved quality enamel paint in an approved manner. (The square metre area of angle iron frame on which the switchgears are erected shall be considered for measurement purpose)

Sqm. 181 26.39 207.00

16-4-12 Providing powder coating of approved colour shade on both sides of provided iron work / MS / CRCA sheet steel work complete including anti- rust treatment in an approved manner.

Sqm. 238 53.84 292.00

16-4-13 Providing Epoxy painting on both side of approved colour shade of provided iron work / MS / CRCA sheet steel work complete along with anti- rust treatment in an approved manner.

Sqm. 451 53.84 505.00

16-4-14 Painting identification number on fittings / equipments with removal and refitting of covers, tubes etc. if required, by marker of indelible ink / enamel paint with the help of ladders, if necessary.

Each 3 4.22 7.00

16-4-15 Scrapping existing paint & Spray painting of Industrial typefluorescent fitting with flat reflector for 2x4' FTL completely. As per specification No. CW-PTG/PFT

Each 58 34.84 93.00

16.5 Plumbing (PLB) 16-5-1 Supplying and erecting G.I.pipe 15 mm dia. ‘B’ class at position with

accessories. As per specification No. CW-PLB/GPMtr. 87 11.61 99.00

16-5-2 Supplying and erecting ISI mark G.I.pipe 20 mm dia.‘B’ class at position with accessories. As per specification No. CW-PLB/GP

Mtr. 107 13.72 121.00

16-5-3 Supplying and erecting ISI mark G.I.pipe 25 mm. dia. ‘B’ class at position with accessories. As per specification no. CW-PLB/GP

Mtr. 152 13.72 166.00

Page 86: Electrical CSR 12-13

16-5-4 Supplying and erecting ISI mark G.I.pipe 32 mm dia.‘B’ class at position with accessories. As per specification No. CW-PLB/GP

Mtr. 192 13.72 206.00

16-5-5 Supplying and erecting ISI mark G.I.pipe 40 mm. dia. ‘B’ class at position with accessories. As per specification No. CW-PLB/GP

Mtr. 223 14.78 238.00

16-5-6 Supplying and erecting ISI mark G.I.pipe 50 mm dia.‘B’ class at position with accessories. As per specification No. CW-PLB/GP

Mtr. 312 14.78 327.00

16-5-7 Supplying and erecting ISI mark G.I.pipe 65 mm. dia. ‘B’ class at position with accessories. As per specification No. CW-PLB/GP

Mtr. 428 14.78 443.00

16-5-8 Supplying and erecting ISI mark G.I.pipe 75/80 mm dia. ‘B’ ‘B’ class at position with accessories. As per specification No. CW-PLB/GP

Mtr. 560 32.73 593.00

16-5-9 Supplying and erecting ISI mark G.I.pipe 100 mm dia. ‘B’ class at position with accessories. As per specification No. CW-PLB/GP

Mtr. 836 32.73 869.00

16-5-10 Supplying and erecting ISI mark G.I. pipe 32 mm. dia ‘C” class at position with accessories. As per specification No. CW-PLB/GP

Mtr. 221 13.72 235.00

16-5-11 Supplying and erecting ISI mark G.I. pipe 40 mm. dia ‘C” class at position with accessories. As per specification No. CW-PLB/GP

Mtr. 260 15.84 276.00

16-5-12 Supplying and erecting ISI mark G.I. pipe 50 mm. dia ‘C” class position with accessories. As per specification No. CW-PLB/GP

Mtr. 356 15.84 372.00

16-5-13 Supplying and erecting ISI mark G.I. pipe 65 mm. dia ‘C” class position with accessories. As per specification No. CW-PLB/GP

Mtr. 485 15.84 501.00

16-5-14 Supplying and erecting ISI mark G.I. pipe 75/80 mm dia ‘C” class position with accessories. As per specification No. CW-PLB/GP

Mtr. 637 32.73 670.00

16-5-15 Supplying and erecting ISI mark G.I. pipe 100 mm dia ‘C” class position with accessories. As per specification No. CW-PLB/GP

Mtr. 941 32.73 974.00

16-5-16 Supplying and erecting high density polythene pipe ISI mark 32 mm 2 dia. suitable for pressure of 6 kg/cm connected to Jet/Submersible pump with required material complete.

Mtr. 51 15.84 67.00

16-5-17 Supplying and erecting high density polythene pipe ISI mark 40 mm 2 dia. suitable for pressure of 6 kg/cm connected to Jet/Submersible pump with required material complete.

Mtr. 76 15.84 92.00

16-5-18 Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 Kg. / Cm2 connected to Jet/Submersible pump with required material complete.

Mtr. 116 15.84 132.00

16.6 Plumbing Accessories 16-6-1 Supplying and erecting 25mm dia. Gun metal foot valve at position

with necessary materials.Each 234 27.45 261.00

16-6-2 Supplying and erecting 40mm dia. Gun metal foot valve at position with necessary materials.

Each 400 27.45 427.00

16-6-3 Supplying and erecting 50mm dia. Gun metal foot valve at position with necessary materials.

Each 494 35.89 530.00

16-6-4 Supplying and erecting 65mm dia. Gun metal foot valve at position with necessary materials.

Each 973 54.9 1028.00

16-6-5 Supplying and erecting 75/80mm dia. Gun metal foot valve at position with necessary materials.

Each 1412 54.9 1467.00

16-6-6 Supplying and erecting 100mm dia. Gun metal foot valve at position with necessary materials.

Each 2296 54.9 2351.00

16-6-7 Supplying and erecting 25mm dia. cast iron foot valve at position with necessary materials.

Each 148 27.45 175.00

16-6-8 Supplying and erecting 40mm dia. cast iron foot valve at position with necessary materials.

Each 308 27.45 335.00

16-6-9 Supplying and erecting 50mm dia. cast iron foot valve at position with necessary materials.

Each 455 35.89 491.00

16-6-10 Supplying and erecting 65mm dia. cast iron foot valve at position with necessary materials.

Each 767 54.9 822.00

16-6-11 Supplying and erecting 75/80mm dia. cast iron foot valve at position with necessary materials.

Each 1153 54.9 1208.00

16-6-12 Supplying and erecting 100mm dia. cast iron foot valve at position with necessary materials.

Each 2529 54.9 2584.00

16-6-13 Supplying and erecting 25mm dia. gun metal sluice valve at position with necessary materials.

Each 567 27.45 594.00

16-6-14 Supplying and erecting 40 mm. dia. gun metal sluice valve at position with necessary materials.

Each 1065 27.45 1092.00

16-6-15 Supplying and erecting 50mm dia. gun metal sluice valve at position with necessary materials.

Each 1677 35.89 1713.00

16-6-16 Supplying and erecting 65mm dia. gun metal sluice valve at position with necessary materials.

Each 3191 54.9 3246.00

16-6-17 Supplying and erecting 75/80mm dia. gun metal sluice valve at position with necessary materials.

Each 3856 54.9 3911.00

16-6-18 Supplying and erecting 100mm dia. gun metal sluice valve at position with necessary materials.

Each 7244 54.9 7299.00

16-6-19 Supplying and erecting Non return valve 25mm dia in position made of gun metal.

Each 460 27.45 487.00

16-6-20 Supplying and erecting Non return valve 40mm dia in position made of gun metal.

Each 772 27.45 799.00

16-6-21 Supplying and erecting Non return valve 50mm dia in position made of gun metal.

Each 1066 35.89 1102.00

Page 87: Electrical CSR 12-13

16-6-22 Supplying and erecting Non return valve 65mm dia in position made of gun metal.

Each 2022 54.9 2077.00

16-6-23 Supplying and erecting Non return valve 75/80mm dia in position made of gun metal.

Each 2568 54.9 2623.00

16-6-24 Supplying and erecting Non return valve 100mm dia in position made of gun metal.

Each 4920 54.9 4975.00

16-6-25 Supplying and erecting C.I. flange 25mm dia with necessary nuts bolts and washers with rubber seal in position.

Each 61 11.61 73.00

16-6-26 Supplying and erecting C.I. flange 40mm dia with necessary nuts bolts and washers with rubber seal in position.

Each 66 11.61 78.00

16-6-27 Supplying and erecting C.I. flange 50mm.dia with necessary nuts bolts and washers with rubber seal in position.

Each 81 11.61 93.00

16-6-28 Supplying and erecting C.I. flange 65mm. dia with necessary nuts bolts and washers with rubber seal in position.

Each 86 11.61 98.00

16-6-29 Supplying and erecting C.I. flange 75/80mm. dia with necessary nuts bolts and washers with rubber seal in position.

Each 101 17.95 119.00

16-6-30 Supplying and erecting C.I. flange 100mm. dia with necessary nuts bolts and washers with rubber seal in position.

Each 201 17.95 219.00

16-6-31 Supplying and erecting 0-100 lb/sq. inch pressure gauge having 4" dia complete with socket for 1/2" G.I. pipe.

Each 352 15.84 368.00

16-6-32 Supplying and erecting 40mm dia. ball type foot valve having C.I. body lined from inside with FRP and synthetic rubber coated (reinforced) ball, leaded fin bronze (IS:318) FRP seat, carbon steel (IS:1363 class 4) fastners, C.I./M.S.Stainer Complete

Each 770 109.79 880.00

16-6-33 Supplying and erecting 50mm dia. ball type foot valve having C.I. body lined from inside with FRP and synthetic rubber coated (reinforced) ball, leaded fin bronze (IS:318) FRP seat, carbon steel (IS:1363 class 4) fastners, C.I./M.S.Stainer Complete

Each 1078 163.63 1242.00

16-6-34 Supplying and erecting 65mm dia. ball type foot valve having C.I. body lined from inside with FRP and synthetic rubber coated (reinforced) ball, leaded fin bronze (IS:318) FRP seat, carbon steel (IS:1363 class 4) fastners, C.I./M.S.Stainer Complete

Each 1574 218.53 1793.00

16-6-35 Supplying and erecting 75/80mm dia. ball type foot valve having C.I. body lined from inside with FRP and synthetic rubber coated (reinforced) ball, leaded fin bronze (IS:318) FRP seat, carbon steel (IS:1363 class 4) fastners, C.I./M.S.Stainer Complete

Each 2167 273.43 2440.00

16-6-36 Supplying and erecting 100mm dia. ball type foot valve having C.I. body lined from inside with FRP and synthetic rubber coated (reinforced) ball, leaded fin bronze (IS:318) FRP seat, carbon steel (IS:1363 class 4) fastners, C.I./M.S.Stainer Complete

Each 4133 328.32 4461.00

Chapter 17 : MISCELLANEOUS (MSC) 17.1 Rewinding

17-1-1 Rewinding the motor of table / pedastal / wall bracket / cabin fans of all type and makes including minor repairs replacing ball bearings, bush bearing, condensor, screws etc.&testing for original speed and consumption with guarantee for 1 year including transportation from site and back

Job 408 106.63 515.00

17-1-2 Rewinding the motor of the ceiling fan 900mm of all types and makes and over hauling including minor repairs replacing ball bearings, bush bearing, condensor, screws etc.& testing for original speed and consumption with guarantee for one year.

Each 408 125.63 534.00

17-1-3 Rewinding the motor of the ceiling fan 1200 mm / 1400 mm of all types and makes and over hauling including minor repairs replacing ball bearing, bush bearing, condensor, screws etc. & testing for original speed and consumption with guarantee for one year.

Each 408 125.63 534.00

17-1-4 Rewinding the motor of the Exhaust fan 900 / 1400 RPM 300 mm of all types and makes and over hauling including minor repairs, replacing ball bearing, bush bearing, condensor, screws etc. & testing for original speed and consumption with guarantee for one year

Each 442 125.63 568.00

17-1-5 Rewinding the motor of the Exhaust fan 900/1400 RPM 375 mm of all types and makes and over hauling including minor repairs, replacing ball bearing, bush bearing, screws etc. & testing for original speed and consumption with guarantee for one year

Each 615 125.63 741.00

17-1-6 Rewinding the motor of the Exhaust fan 900/1400 RPM 450 mm of all types and makes and over hauling including minor repairs, replacing ball bearing, bush bearing, condensor, screws etc. & testing for original speed and consumption with guarantee for one year

Each 684 155.19 839.00

17-1-7 Rewinding of electric motor upto 1H.P. single phase upto 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, replacing ball bearing, bush bearing, condensor, screws etc. testing for the original speed and no load consumption with guarantee for one year.

Each 715 232.25 947.00

Note :- Item No. 18-1-7 is for rewinding of motors other than table / pedastal / cabin / wall mounting / ceiling / Exhaust fan.

Page 88: Electrical CSR 12-13

17-1-8 Rewinding of electric motor upto 1H.P. three phase upto 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, replacing ball bearing, bush bearing, screws etc. testing for the original speed and no load consumption with guarantee for one year.

Each 1216 204.81 1421.00

17-1-9 Rewinding of electric motor upto 2 H.P. three phase upto 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, replacing ball bearing, bush bearing, screws etc. testing for the original speed and no load consumption with guarantee for one year

Each 1660 204.81 1865.00

17-1-10 Rewinding of electric motor upto 3 H.P. three phase upto 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, replacing ball bearing, bush bearing, screws etc. testing for the original speed and no load consumption with guarantee for one year

Each 1798 243.87 2042.00

17-1-11 Rewinding of electric motor upto 5 H.P. three phase upto 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, replacing ball bearing, bush bearing, screws etc. testing for the original speed and no load consumption with guarantee for one year

Each 3082 420.17 3502.00

17-1-12 Rewinding of electric motor upto 7.5 H.P. three phase upto 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, replacing ball bearing, bush bearing, screws etc. testing for the original speed and no load consumption with guarantee for one year

Each 3576 533.13 4109.00

17-1-13 Rewinding of electric motor upto 10 H.P.three phase upto 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, replacing ball bearing, bush bearing, screws etc. testing for the original speed and no load consumption with guarantee for one year

Each 3857 557.41 4414.00

17-1-14 Rewinding of electric motor upto 12.5 H.P. three phase upto 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, replacing ball bearing, bush bearing, screws etc. testing for the original speed and no load consumption with guarantee for one year

Each 4548 608.08 5156.00

17-1-15 Rewinding of electric motor upto 15 H.P. three phase upto 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, replacing ball bearing, bush bearing, screws etc. testing for the original speed and no load consumption with guarantee for one year

Each 5354 737.93 6092.00

17-1-16 Rewinding of electric motor upto 20 H.P. three phase upto 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, replacing ball bearing, bush bearing, screws etc. testing for the original speed and no load consumption with guarantee for one year

Each 6329 887.84 7217.00

17-1-17 Rewinding of submersible pump motor of all types and makes upto and including 5 HP with coated copper wires & overhauling with minor repairs, replacing ball bearing, bush bearing, screws etc. testing for the original speed, H.P. and no load consumption & guarantee for one year.

H.P. 1069 441.28 1510.00

17-1-18 Rewinding of submersible pump motor of all types and makes above 5 H.P. upto 15 H.P with coated copper wires & overhauling with minor repairs, replacing ball bearing, bush bearing, screws etc. testing for the original speed, H.P. and no load consumption & guarantee for one year.

H.P. 1309 441.28 1750.00

Note :- 1) Burnt ceiling fans and motor older than 10 yrs shall not be rewound. 2) Rates for rewinding of 2800/ 2900 RPM motors, shall be decreased by 5%. 3) The dismantled material shall be retained by the contractor.

17.2 Replacement 17-2-1 Replacing the existing bearing of approved make for electric motor

A.C single phase / 3 phase upto 1 H.P. of all types with due alignment of the shaft and tested.

Each 213 51.73 265.00

17-2-2 Replacing the existing bearing of approved make for A.C electric motor 3 phase 2 H.P. to 3 H.P. of all types with due alignment of the shaft and tested.

Each 289 51.73 341.00

17-2-3 Replacing the existing bearing of approved make for electric motor 5 H.P. & 7.5 H.P. of all types with due alignment of the shaft and tested.

Each 445 76.01 521.00

17-2-4 Replacing the existing bearing of approved make for electric motor 10 H.P. & 12.5 H.P. of all types with due alignment of the shaft and tested.

Each 616 76.01 692.00

17-2-5 Replacing the existing bearing of approved make for electric motor 15H.P.to 20 H.P. of all types with due alignment of the shaft and tested.

Each 1059 101.35 1160.00

17-2-6 Replacing the existing ball bearing of table/ cabin/ pedestal/ ceiling/ exhaust fan complete with alignment of shaft & tested.

Each 148 51.73 200.00

17-2-7 Replacing the existing Bush/ rubber, ring, washers of table/ cabin/ pedestal/ ceiling/ exhaust fan complete with alignment of shaft & tested.

Each 50 25.34 75.00

17-2-8 Replacing the existing capacitor of 2.5 microfarad for all types of fan complete with wiring.

Each 29 6.33 35.00

17-2-9 Replacing the existing capacitor of 4 microfarad for all types of fittings complete with wiring.

Each 41 6.33 47.00

Note :- 1) Above rates are applicable for replacement of bearing only.

17.3 Accessories 17-3-1 Filtration of Transformer oil on site till satisfactory test results. Liter 8 6.33 14.00

Page 89: Electrical CSR 12-13

17-3-2 Supplying and topping up filtered transformer oil of approved make with test certificate.

Liter 154 9.5 164.00

17-3-3 Supplying and erecting No-Volt-Coil L&T make for motor starters upto 12.5 H.P.

Each 206 51.73 258.00

17-3-4 Supplying and erecting No-Volt-Coil L&T make of type ML-2 for 15 H.P.to 30 H.P.motor

Each 562 51.73 614.00

17-3-5 Supplying and erecting No-Volt-Coil L&T make of type ML-4 above 30 H.P.to 60 H.P. motor

Each 829 51.73 881.00

17-3-6 Supplying and erecting thermal Overload Relay L&T make for MK 1 motorstarter suitable for up to 12.5 HP

Each 827 51.73 879.00

17-3-7 Supplying and erecting thermal over load relay L&T make ML-1/ ML-1.5 for motor starter 15 H.P. to 30 H.P.

Each 1390 51.73 1442.00

17-3-8 Supplying and erecting thermal over load relay L&T make MK-2 / ML-3 for motor starter above 30 H.P.to 60 H.P.

Each 2062 51.73 2114.00

17-3-9 Supplying & erecting L&T make timer for MK-1 motor starter suitable from upto 12.5 H.P.

Each 719 51.73 771.00

17-3-10 Supplying & erecting L&T make timer for ML-2 motor starter suitable from 15 H.P to 30 H.P.

Each 1600 51.73 1652.00

17-3-11 Supplying & erecting thermal timer HT 2000 L&T make above 30 H.P. to 60 H.P.

Each 1789 51.73 1841.00

17-3-12 Supplying & erecting contactor MK-1, LT make for motor starter upto 12.5 H.P.

Each 860 51.73 912.00

17-3-13 Supplying and erecting contactor L&T make ML-1.5 or suitable from MN series for motor starter suitable from 15 H.P. to 30 H.P.

Each 1583 51.73 1635.00

17-3-14 Supplying and erecting contactor L&T make ML2 or suitable from MN series for motor starter suitable above 30 HP to 60 HP

Each 3226 51.73 3278.00

17-3-15 Supplying and erecting contactor L&T make ML-3 or suitable from MN series for motor starter suitablefrom 40 HP to 50 HP

Each 4362 516.24 4878.00

17-3-16 Supplying and erecting contactor L&T make ML-4 or suitable from MN series for motor starter suitable from 60 HP to 75 HP.

Each 7101 51.73 7153.00

17-3-17 Dismantling the existing ceiling fan of various sizes and replacing the bolt and nuts at reel insulator and at bottom of the down rod with half threaded bolt of 3/8” dia 2-1/2” to 3-1/2” long and 5/16” dia 1-3/4” to 2-1/4” long respectively required sizes with 2 plate washers with oiling, greasing and painting the date of repair and re-erecting at position.

Each 50 76.01 126.00

17-3-18 Replacing suitable capacity motor of water pump of air cooler of any capacity and type in lieu of old one.

Each 464 51.73 516.00

17-3-19 Checking the existing Indoor faulty fitting, finding the fault, repairing by provided necessary material, if any, and putting into beneficial use with necessary Tools & Tackles.

Each 0 35.89 36.00

17-3-20 Checking the existing outdoor faulty fitting, finding the fault, repairing by provided necessary material, if any, and putting into beneficial use with necessary Tools & Tackles.

Each 0 71.79 72.00

Chapter 18 : Dismantled Items 18-1-1 PVC arm/unarm.cable & wire (Allum) kg 11 0 11.00 18-1-2 PVC arm/unarm.cable & wire (Copper) kg 50 0 50.00 18-1-3 Allum. Metalic Matrials kg 62 0 62.00 18-1-4 HG / M.S/G.I.Metalic Matrials / Pole etc. kg 25 0 25.00 18-1-5 Copper /Brass materials kg 138 0 138.00 18-1-6 Wooden Materials kg 5 0 5.00 18-1-7 PVC Pipe / PVC Materials kg 5 0 5.00 18-1-8 Paper Cartoons & Paper Boxes. kg 4 0 4.00 18-1-9 I.C.Switches / M.C. Switches/ D.P. / D.B./ T.P. /feeder piller etc. kg 13 0 13.00 18-1-10 All type of Meters.(Ammeter / Voltmer ect.) kg 25 0 25.00 18-1-11 All type of O.C.B./ A.C.B/ V.C.B Each 1300 0 1300.00 18-1-12 All type of ceiling fan, cabin fan,Bracket fan, pedastal fan and

table fan.Each 150 0 150.00

18-1-13 All type of Air circulator and pedastal type Air circulator (New Proposed)

Each 500 0 500.00

18-1-14 All type of Fluo. Tube Fitting / M,V./M.H. Fitting / S.V.Fitting Each 21 0 21.00 18-1-15 All type of Geysor up to 6 KW Each 100 0 100.00 18-1-16 All type of accessories such as Tube starter /Bell /Holder/ Ceiling

Rose/ MCB etc. kg 11 0 11.00

18-1-17 All type of Chokes / condensor / small coils / motor starter etc. kg 17 0 17.00 18-1-18 Lift Ropes / Belt types / Appliances & equipments kg 20 0 20.00 18-1-19 All type of Hot water Boilers Each 400 0 400.00 18-1-20 All type of Electric motor HP 340 0 340.00 18-1-21 All type of Water pumpset. HP 340 0 340.00 18-1-22 All type of A.C compressor T/R 500 0 500.00 18-1-23 All type of A.C.unit.(Window) T/R 2000 0 2000.00 18-1-24 All type of A.C.unit.(Split) T/R 2100 0 2100.00 18-1-25 All type of Indoor unit of split A.C. Each 800 0 800.00 18-1-26 Copper piping of A.C. kg 135 0 135.00 18-1-27 Water cooler instant type Each 900 0 900.00 18-1-28 Water cooler storage type Liter 10 0 10.00 18-1-29 Refrigerator upto 165 ltr. Each 1452 0 1452.00

Page 90: Electrical CSR 12-13

18-1-30 Refrigerator above 165 ltr. Each 2000 0 2000.00 18-1-31 Exhaust fan 9" sweep. Each 135 0 135.00 18-1-32 Exhaust fan 12" sweep. Each 151 0 151.00 18-1-33 Exhaust fan 15" sweep. Each 200 0 200.00 18-1-34 Exhaust fan 18" sweep. Each 330 0 330.00 18-1-35 Exhaust fan 24" sweep. Each 400 0 400.00 18-1-36 Air cooler of any size(Without Fan) Each 500 0 500.00 18-1-37 Air cooler of any size(With Fan) Each 800 0 800.00 18-1-38 Transformer Oil Liter 5 0 5.00 18-1-39 D.G. Set. kVA 100 0 100.00 18-1-40 Transformer kVA 40 0 40.00 18-1-41 Telephone Exchange (EPABX) Each 1100 0 1100.00 18-1-42 Telephone instrument . Each 50 0 50.00 18-1-43 Water Purifier Each 80 0 80.00 18-1-44 Inverter /UPS kVA 50 0 50.00 18-1-45 Voltage stabilizer kVA 50 0 50.00 18-1-46 Amplifier small Each 400 0 400.00 18-1-47 Amplifier Big Each 450 0 450.00 18-1-48 Mikes Each 70 0 70.00

Note :- Rates for Items which are not covered in above list should be calculated on the basis of material / equipments considering it's site condition and prevailing market rates and approval should be taken from concerned Superintending Engineer ( Electrical)