1
1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 22 23 24 13 A B C D E F H I J K L M P Speech Therapy 2 Speech Therapy 4 Book TR Room 5 Medical Store 6 Book TR Room 1 Unoccupied Unoccupied Unoccupied Unoccupied Unoccupied Unoccupied Unoccupied Unoccupied WC & Shower 8 Staff WC 9 Hall 10 Womens Toilets 11 Mens Toilets 13 Wound Clinic 15 Medical Store 16 Wound Clinic 17 Bookable Room 18 Family Rm/Care Doc 19 Waiting Area 21 Community Welfare 22 Bookable Room 23 Room 24 Child Health 25 Sound Proof Room 26 Unoccupied Unoccupied Womens WC 12 Mens WC 14 Circuit1 Panel 1 Coffer Light - Parabolic Rectangular Reception 20 Circuit9 Panel 1 Coffer Light - Parabolic Rectangular Circuit11 Panel 1 Coffer Light - Parabolic Rectangular Circuit10 Panel 1 Coffer Light - Parabolic Rectangular Circuit12 Panel 1 Coffer Light - Parabolic Rectangular Circuit<unnamed> Coffer Light - Parabolic Rectangular Circuit6 Panel 2 Coffer Light - Parabolic Rectangular Circuit5 Panel 2 Coffer Light - Parabolic Rectangular Circuit4 Panel 2 Coffer Light - Parabolic Rectangular Circuit3 Panel 2 Coffer Light - Parabolic Rectangular Circuit2 Panel 2 Coffer Light - Parabolic Rectangular Circuit1 Panel 2 Recessed Direct-Indirect Light - Asymmetrical Circuit8 Panel 1 Coffer Light - Parabolic Rectangular Circuit7 Panel 1 Recessed Direct-Indirect Light - Asymmetrical Circuit6 Panel 1 Coffer Light - Parabolic Rectangular Circuit5 Panel 1 Coffer Light - Parabolic Rectangular Circuit4 Panel 1 Coffer Light - Parabolic Rectangular Circuit3 Panel 1 Coffer Light - Parabolic Rectangular Circuit11 Panel 2 Recessed Direct-Indirect Light - Asymmetrical Circuit12 Panel 2 Recessed Direct-Indirect Light - Asymmetrical Circuit8 Panel 3 Recessed Direct-Indirect Light - Asymmetrical Circuit7 Panel 3 Recessed Direct-Indirect Light - Asymmetrical Circuit3 Panel 3 Ceiling Light - Flat Round Recessed Direct-Indirect Light - Asymmetrical Circuit10 Panel 3 Coffer Light - Parabolic Rectangular Circuit9 Panel 3 Coffer Light - Parabolic Rectangular Circuit6 Panel 3 Coffer Light - Parabolic Rectangular Circuit4 Panel 3 Coffer Light - Parabolic Rectangular Circuit5 Panel 3 Coffer Light - Parabolic Rectangular Circuit2 Panel 1 Recessed Direct-Indirect Light - Asymmetrical Coffer Light - Parabolic Rectangular Scale LECTURER Drawn by Date Project number Institute of Technology Carlow BSc. in Architectural Technology Year 3 2015-2016 1 : 200 21/04/2016 15:20:34 Electrical Plan Layout 3 Calow Primary Health Care Centre Issue Date Xhevdet Haliti Dan O Sullivan, Noel Dunne, Mark Duffy A101 1 : 200 Ground floor - Ceiling Electrical layout 1 Notes: Total Est. Demand Current: 6 A Total Conn. Current: 9 A Total Est. Demand: 4034 VA Other 0 VA 0.00% 0 VA Total Conn. Load: 6112 VA Lighting - Dwelling Unit 6112 VA 66.00% 4034 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps: 7 A 10 A 11 A 1504 VA 2208 VA 2400 VA 12 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.1 A 11 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.1 A 10 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.1 A 9 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A 8 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 4.2 A 7 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.7 A 6 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A 5 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A 4 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.4 A 3 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A 2 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 0.6 A 1 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.4 A Circuit Number Circuit Designation Type of Wiring Circuit Conductors (csa) Live, Neutral, CPC Max Disconnection Time allowed by BS7671 Protective Device BS(EN) PD Type number PD Rating Short Circuit Capacity (kA) RCD Operating current (mA) Maximum Zs Permitted by BS 7671 A B C Notes: Enclosure: Type 1 MCB Rating: Mounting Type: Surface Mains Rating: 100 A DB supplied from: No. of Phases: 3 Mains Type: Location of DB: Space 1 Voltage: 230/400 Wye A.I.C. Rating: DB Schedule: Panel 1 Institute of Technology Carlow Notes: Total Est. Demand Current: 6 A Total Conn. Current: 9 A Total Est. Demand: 4245 VA Other 0 VA 0.00% 0 VA Total Conn. Load: 6432 VA Lighting - Dwelling Unit 6432 VA 66.00% 4245 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps: 7 A 12 A 9 A 1600 VA 2784 VA 2048 VA 12 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.2 A 11 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 5.3 A 10 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.1 A 9 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.1 A 8 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 0.6 A 7 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 0.8 A 6 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A 5 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A 4 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A 3 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A 2 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 3.5 A 1 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.2 A Circuit Number Circuit Designation Type of Wiring Circuit Conductors (csa) Live, Neutral, CPC Max Disconnection Time allowed by BS7671 Protective Device BS(EN) PD Type number PD Rating Short Circuit Capacity (kA) RCD Operating current (mA) Maximum Zs Permitted by BS 7671 A B C Notes: Enclosure: Type 1 MCB Rating: Mounting Type: Surface Mains Rating: 100 A DB supplied from: No. of Phases: 3 Mains Type: Location of DB: Space 1 Voltage: 230/400 Wye A.I.C. Rating: DB Schedule: Panel 2 Institure of Technology Carlow Symmetrical design, no required top or bottom mountings Single-piece deadfront – no filler plates needed Smaller, lighter panel than Spectra Series panelboards Easy-to-install galvanized enclosures with removable endwalls Ready-to-install hinged trim options Branch-bus direct connection Up to 600A breaker mounted as a branch device Deeper (8"), wider (30") A-Series box to accommodate larger wire sizes Double branched 150A (ED/SE) and 225A (QD) breakers Vertically mounted main circuit breakers in 800A Captive hardware on branch breakers Staggered, center-mounted, larger frame breakers (SG, SF) for easy installation Bus-connected TVSS for maximum surge protection Narrow design to minimize footprint Enclosure available in NEMA Type 1, Type 3R/12, Type 4/4X An exceptional general lighting product that performs well in large spaces with high ceilings. Especially suitable for open office areas, public indoor spaces, libraries and airport waiting areas. Moon Two - High frequency direct / indirect recessed luminaires are a range of high efficiency luminaires designed to accommodate PL-L & T5 fluorescent lamps. These are suitable for general lighting in retail & commercial applications. Typical electrical room layout with suspended ceiling and recessed coffer lighting shown. Distrobution panel boards locate at Basement

Electrical Lighing Layoout

Embed Size (px)

Citation preview

12

3

45

67

89

10

11

12

14

15

16

17

18

19

20

21

22

23

24

13

A

B

CD

E

F

H

I

J

K

L

M

PSpeech Therapy

2

Speech Therapy

4

Book TR Room

5

Medical Store

6

Book TR Room

1

Unoccupied

Unoccupied

Unoccupied

Unoccupied

Unoccupied

Unoccupied

Unoccupied

Unoccupied

WC & Shower

8Staff WC

9

Hall

10

Womens Toilets

11

Mens Toilets

13

Wound Clinic

15

Medical Store

16

Wound Clinic

17

Bookable Room

18

Family Rm/Care Doc

19

Waiting Area

21Community Welfare

22Bookable Room

23

Room

24Child Health

25Sound Proof Room

26

Unoccupied

Unoccupied

Womens WC

12

Mens WC

14

Circuit1Panel 1

Coffer Light -Parabolic

Rectangular

Reception

20

Circuit9Panel 1

Coffer Light -Parabolic

Rectangular

Circuit11Panel 1

Coffer Light -Parabolic

Rectangular

Circuit10Panel 1

Coffer Light -Parabolic

Rectangular

Circuit12Panel 1

Coffer Light -Parabolic

Rectangular

Circuit<unnamed>Coffer Light -

ParabolicRectangular

Circuit6Panel 2

Coffer Light -Parabolic

Rectangular

Circuit5Panel 2

Coffer Light -Parabolic

Rectangular

Circuit4Panel 2

Coffer Light -Parabolic

Rectangular

Circuit3Panel 2

Coffer Light -Parabolic

Rectangular

Circuit2Panel 2

Coffer Light -Parabolic

Rectangular

Circuit1Panel 2

RecessedDirect-Indirect

Light -Asymmetrical

Circuit8Panel 1

Coffer Light -Parabolic

Rectangular

Circuit7Panel 1

RecessedDirect-Indirect

Light -Asymmetrical

Circuit6Panel 1

Coffer Light -Parabolic

Rectangular

Circuit5Panel 1

Coffer Light -Parabolic

Rectangular

Circuit4Panel 1

Coffer Light -Parabolic

Rectangular

Circuit3Panel 1

Coffer Light -Parabolic

Rectangular

Circuit11Panel 2

RecessedDirect-Indirect

Light -Asymmetrical

Circuit12Panel 2

RecessedDirect-Indirect

Light -Asymmetrical

Circuit8Panel 3

RecessedDirect-Indirect

Light -Asymmetrical

Circuit7Panel 3

RecessedDirect-Indirect

Light -Asymmetrical

Circuit3Panel 3

Ceiling Light - FlatRound

RecessedDirect-Indirect

Light -Asymmetrical

Circuit10Panel 3

Coffer Light -Parabolic

Rectangular

Circuit9Panel 3

Coffer Light -Parabolic

Rectangular

Circuit6Panel 3

Coffer Light -Parabolic

Rectangular

Circuit4Panel 3

Coffer Light -Parabolic

RectangularCircuit5Panel 3

Coffer Light -Parabolic

Rectangular

Circuit2Panel 1

RecessedDirect-Indirect

Light -Asymmetrical

Coffer Light -Parabolic

Rectangular

Scale

LECTURER

Drawn by

Date

Project number

Institute of Technology CarlowBSc. in Architectural Technology

Year 3 2015-2016

1 : 200

21/0

4/20

16 1

5:20

:34

Electrical Plan Layout

3

Calow Primary Health Care Centre

Issue Date

Xhevdet Haliti

Dan O Sullivan, Noel Dunne,Mark Duffy

A101

1 : 200

Ground floor - CeilingElectrical layout1

Notes:

Total Est. Demand Current: 6 ATotal Conn. Current: 9 A

Total Est. Demand: 4034 VAOther 0 VA 0.00% 0 VA Total Conn. Load: 6112 VALighting - Dwelling Unit 6112 VA 66.00% 4034 VALoad Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 7 A 10 A 11 A1504 VA 2208 VA 2400 VA

12 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.1 A11 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.1 A10 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.1 A9 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A8 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 4.2 A7 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.7 A6 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A5 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A4 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.4 A3 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A2 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 0.6 A1 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.4 A

CircuitNumber

CircuitDesignation Type of Wiring

Circuit Conductors (csa) Live,Neutral, CPC

MaxDisconnectionTime allowed

by BS7671

ProtectiveDeviceBS(EN)

PD Typenumber PD Rating

ShortCircuit

Capacity(kA)

RCDOperating

current (mA)

Maximum ZsPermitted by

BS 7671

A B C

Notes:

Enclosure: Type 1 MCB Rating:Mounting Type: Surface Mains Rating: 100 A

DB supplied from: No. of Phases: 3 Mains Type:Location of DB: Space 1 Voltage: 230/400 Wye A.I.C. Rating:

DB Schedule: Panel 1 Institute ofTechnology Carlow

Notes:

Total Est. Demand Current: 6 ATotal Conn. Current: 9 A

Total Est. Demand: 4245 VAOther 0 VA 0.00% 0 VA Total Conn. Load: 6432 VALighting - Dwelling Unit 6432 VA 66.00% 4245 VALoad Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 7 A 12 A 9 A1600 VA 2784 VA 2048 VA

12 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.2 A11 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 5.3 A10 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.1 A9 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.1 A8 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 0.6 A7 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 0.8 A6 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A5 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A4 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A3 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A2 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 3.5 A1 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.2 A

CircuitNumber

CircuitDesignation Type of Wiring

Circuit Conductors (csa) Live,Neutral, CPC

MaxDisconnectionTime allowed

by BS7671

ProtectiveDeviceBS(EN)

PD Typenumber PD Rating

ShortCircuit

Capacity(kA)

RCDOperating

current (mA)

Maximum ZsPermitted by

BS 7671

A B C

Notes:

Enclosure: Type 1 MCB Rating:Mounting Type: Surface Mains Rating: 100 A

DB supplied from: No. of Phases: 3 Mains Type:Location of DB: Space 1 Voltage: 230/400 Wye A.I.C. Rating:

DB Schedule: Panel 2 Institure ofTechnology Carlow

Symmetrical design, no required top or bottom mountingsSingle-piece deadfront – no filler plates neededSmaller, lighter panel than Spectra Series panelboardsEasy-to-install galvanized enclosures with removable endwallsReady-to-install hinged trim optionsBranch-bus direct connectionUp to 600A breaker mounted as a branch deviceDeeper (8"), wider (30") A-Series box to accommodate larger wire sizesDouble branched 150A (ED/SE) and 225A (QD) breakersVertically mounted main circuit breakers in 800ACaptive hardware on branch breakersStaggered, center-mounted, larger frame breakers (SG, SF) for easy installationBus-connected TVSS for maximum surge protectionNarrow design to minimize footprintEnclosure available in NEMA Type 1, Type 3R/12, Type 4/4X

An exceptional general lighting product that performs well in large spaces with high ceilings. Especially suitable for open office areas,public indoor spaces, libraries and airport waiting areas.

Moon Two - High frequency direct / indirect recessed luminaires are a range ofhigh efficiency luminaires designed to accommodate PL-L & T5 fluorescentlamps. These are suitable for general lighting in retail & commercial applications.

Typical electrical room layout with suspended ceilingand recessed coffer lighting shown.

Distrobution panel boards locate at Basement