Electrical Test & MeasurementEquipment Rental Catalog

2021

n Aviation

n Wind turbines

n Rail

n Marine

n Oil and gas pipelines

n Automotive and EV

n Cable manufacturers

n And much more

Are you a heavyweight in electrical testing?

The Megger DLRO2 isn’t! The DLRO2, a 2-amp DucterTM Low Resistance Ohmmeter is a lightweight, handheld instrument that offers fast, accurate, repeatable measurements, even in noisy environments. One of its features includes a brand new ‘difference’ meter that offers repetitive measurements to be easily compared with an initial reference measurement. Other features include:

n Long test leads mode at 1A without compromising test speed

n IP54 rating allows for outdoor use with protection against dust and moisture

n Standard AA rechargeable NiMH batteries assure that the unit is always ready to test

Another point worth mentioning is the included Kelvin clip and probe test leads! These provide more testing flexibility for you.

The DLRO2 can measure low resistance values across a wide range of applications, including:

n Aviation

n Wind turbines

n Rail

n Marine

n Oil and gas pipelines

n Automotive and EV

n Cable manufacturers

n And much more

Are you a heavyweight in electrical testing?

The Megger DLRO2 isn’t! The DLRO2, a 2-amp DucterTM Low Resistance Ohmmeter is a lightweight, handheld instrument that offers fast, accurate, repeatable measurements, even in noisy environments. One of its features includes a brand new ‘difference’ meter that offers repetitive measurements to be easily compared with an initial reference measurement. Other features include:

n Long test leads mode at 1A without compromising test speed

n IP54 rating allows for outdoor use with protection against dust and moisture

n Standard AA rechargeable NiMH batteries assure that the unit is always ready to test

Another point worth mentioning is the included Kelvin clip and probe test leads! These provide more testing flexibility for you.

The DLRO2 can measure low resistance values across a wide range of applications, including:

Megger MIT series The Megger MIT series of 5, 10 and 15 kV insulation testers perform better than any other testers on the market today. In fact, some say the instruments are the ‘gold standard’ of insulation testers.

Some of the features of the units include:

Unique dual-case design for added protection

Double insulated test leads for extra safety and reliability

Advanced memory storage with time/date stamp

Unrivaled guard terminal performance

High noise immunity – 3 ma (5 and 10 kV) and 6ma (15 kV)

Safety rating: CATIV 600 V to 3000m (5 and 10kV); CATIV 1000 to 3000 m (15kV)

Setting the standard in insulation testing.

So set the standard in your insulation testing with the MIT series from Megger.

Worth their weight in gold!

Winding Resistance with Core Demagnetization

Current Transformer Test Sets

Why Raytech?99% of All Raytech Equipment Sold is Still in Operation Today Over 20 years of innovative design and manufacturing means Raytech's equipment is built for the harsh environments of the testing industry. Your test equipment is assured to be in service for a long time. 5-Year Standard Warranty The 5-Year Standard Warranty means years of trouble-free operation, without instrument replacement costs. You can be confident in our instruments’ performance for years to come. Reliable Support for 100% of the Equipment We’ve Ever Built Raytech supports every product we’ve ever introduced. Your equipment will remain functional, even after it is no longer being sold. We fully support all of our products for the entire time you own them. #1 in Customer Support • No-charge service evaluations • Hardware, firmware, and software updates • Lifetime product support • Professional, expert service and advice • Certification services provided • Short repair turnaround times Five Product Lines: Straight-Forward, Easy to Set Up, and Easy to Use

Single and 3-Phase RatiometersPower Factor Test Sets

Toll Free: 888 484 3779 | Phone 267 404 2676 118 South 2nd Street, Perkasie, PA 18944 www.RaytechUSA.com

10A and 200A Contact Resistance

RaytechUSA.com Toll Free: 888 484 3779 | Phone: 267 404 2676 118 South 2nd Street, Perkasie, PA 18944

ProTechAds.qxp_Reliability Ad 2/24/21 8:56 AM Page 2

Winding Resistance with Core Demagnetization

Current Transformer Test Sets

Why Raytech?99% of All Raytech Equipment Sold is Still in Operation Today Over 20 years of innovative design and manufacturing means Raytech's equipment is built for the harsh environments of the testing industry. Your test equipment is assured to be in service for a long time. 5-Year Standard Warranty The 5-Year Standard Warranty means years of trouble-free operation, without instrument replacement costs. You can be confident in our instruments’ performance for years to come. Reliable Support for 100% of the Equipment We’ve Ever Built Raytech supports every product we’ve ever introduced. Your equipment will remain functional, even after it is no longer being sold. We fully support all of our products for the entire time you own them. #1 in Customer Support • No-charge service evaluations • Hardware, firmware, and software updates • Lifetime product support • Professional, expert service and advice • Certification services provided • Short repair turnaround times Five Product Lines: Straight-Forward, Easy to Set Up, and Easy to Use

Single and 3-Phase RatiometersPower Factor Test Sets

Toll Free: 888 484 3779 | Phone 267 404 2676 118 South 2nd Street, Perkasie, PA 18944 www.RaytechUSA.com

10A and 200A Contact Resistance

RaytechUSA.com Toll Free: 888 484 3779 | Phone: 267 404 2676 118 South 2nd Street, Perkasie, PA 18944

ProTechAds.qxp_Reliability Ad 2/24/21 8:56 AM Page 2

Toll Free: 888 484 3779 | Phone: 267 404 2676 118 South 2nd Street, Perkasie, PA 18944

With a standard 5-YEAR warranty, you can trust Raytech equipment is built for the harsh environments of our testing industry.

Free service evaluations and lifetime product support

guarantees quality service is fast and easy.

Offering the following easy to set up, and easy to use product lines:

RaytechUSA.com

• Transformer Ratiometers

• Winding Resistance

• Contact Resistance

• Current Transformer Test Sets

• Power Factor Test Sets

Reliability You Need Support You Deserve

ProTechAds.qxp_Reliability Ad 2/24/21 8:56 AM Page 1

D a l l a s1517 W Carrier Pkwy, Ste 116

Grand Prairie, Texas 75050(972) 352-5550

C h i c a g o1501 Wright Blvd

Schaumburg, Illinois 60193(847) 434-5808

A t l a n t a880 Veterans Memorial Hwy, SE

Mableton, Georgia 30126(678) 210-1423

N e w Yo r k70 Triangle Blvd

Carlstadt, New Jersey 07072(201) 450-9743

H o u s t o n14251 Gulfstream Park Dr

Webster, Texas 77598(832) 251-7047

R e n o -Ta h o e924 Greg St

Sparks, Nevada 89431(775) 984-5223

We know that you need experienced people who understand yourelectrical test and measurement equipment needs and have a track record of delivering on time, every time. To better serve our customers, we’ve stocked all of our locations with the inventory

you need to get the job done.

With local inventory for competitive shipping rates and equipment application support from a dedicated team with decades of experience, you can trust Protec to go above and beyond all others

for your satisfaction. We’re the Electrical Test and Measurement Equipment Rental Expertsfor a reason, let us show you how we earned that reputation.

Large enough to serve your needs, small enough to care.

Lo s A n g e l e s2935 E Ricker Way

Anaheim, California 92806(657) 758-5098

D e nve r12050 E 45th Ave, Unit 400

Denver, Colorado 80239(720) 826-6378

Calibration Labs

Rent Quality Products from Industry-Leading Manufacturers

Toll Free: (866) 352-5550

Protec offers a full-service Asset Management service customized for your individual needs that includes:

• Complete in-house maintenance, quality control, logistics, repair and calibration

• Analytics to drive educated business decisions (ROI, Yield, and Utilization)

• Inventory access & management 24/7 through our customer portal & mobile app

• Discounted rentals for supplemental equipment

• Multiple locations for housing your equipment based on demand

• 24/7 support and a dedicated customer service team

Asset ManagementAccurate and affordable electrical testequipment calibration services for many makes and models of electrical test and measurement equipment.

• Expedited and Emergency Service - When calibrated equipment is needed quickly

• Calibration Management Service - Automatic notification of equipment coming due for calibration

• Equipment Rental Options - We offer rental equipment, so work can continue while equipment is being calibrated

• Now calibrating torque wrenches

• Ask about our on-site capabilities

Two Calibration Lab Locations to Serve You:

1517 W Carrier Pkwy, Ste 116 Grand Prairie, Texas 75050

1501 Wright Blvd Schaumburg, Illinois 60193

ABBAdwelAEMCAgilentAlberAllen-BradleyAltekAmetekAmprobeAqua-TronicsAstro-MedBakerBender

BK PrecisionCarriereCooper Power SystemsDentDILODobleDranetzEA TechnologyEaton Cutler HammerElectrical Test InstrumentsEmersonENOSERVFLIR

FlukeFujiGEHaefelyHD ElectricHigh VoltageHiokiHipotronicsHoneywellHuksefluxHV DiagnosticsIRIS PowerManta

MeggerMerlin GerinMetrelMikronOlympusOmicronPdMA CorporationPhenixPMDTPowerComm SolutionsRaytechRH SystemsRx Monitoring Services

SBSSchweitzerSeawardSiemensSKF (Baker)SonelSquare D by SchneiderSummit TechnologyTransmationUtility Relay CompanyVacuum InterruptersVanguardWIKA

To Be the Best at What We Do …By a Wide MarginWe accomplish this by employing a team of professionals with a passion to be the best and a commitment to excellence in everything we do.

Character & IntegrityBuilding trust through ethical and honorable conduct in all our dealings with customers, vendors, and one another.

Customer Focused TeamworkA commitment to each other and an exceptionally high level of interpersonal team support gives us the ability to make your emergency our emergency, and your success our success. Everything we do is geared toward making you more competitive and successful in the marketplace.

Superior Customer ServiceWe care about our customers and their success, and strive to provide superior customer service, from working after hours to driving 800 miles overnight for an emergency job … we are there when and where you need us.

Nobody Works Harder For You Than Protec

We understand that you need experienced people to align you with the proper electrical test andmeasurement equipment, in the right place at the right time.

That’s why we are the number one choice for mission criti-cal equipment, where time, quality and service are vital.

About Us

The Electrical Test & MeasurementEquipment Rental Experts

Better ServiceProtec Equipment Resources offers a large, nationwide rental fleet of electrical test and measurement equipment, and to better serve our customers, all of our locations are stocked with inventory.

Nationwide InventoryWith local inventory for better shipping rates and electrical testing application support from a team who works hard to get to know your special requirements, you can count on Protec to do what it takes to help you get the job done right. Give us a call and put us to the test.

t 866-352-5550 protecequip.com

Atlanta | Chicago | Dallas | Denver | HoustonLos Angeles | New York | Reno-Tahoe

NEW INVENTORY

N E W I N V E N TO R Y

We are please to announce the addition of the following equipment to our already extensive catalog of electrical test and measurement equipment. Protec carries a full inventory of equipment for all your testing needs.

• For more information refer to page 92

AEMC PEL 103Power and Energy Logger

• For more information refer to page 8

Aqua-Tronics EG 3000 TSecondary Cable Fault Locator

• For more information refer to page 63

AEMC 6536Insulation Resistance Test Set

• For more information refer to page 51

Doble TR3171Motion/Travel Transducer

NEW INVENTORY

• For more information refer to page 112

Omicron FRANEO 800Sweep Frequency Response Analyzer

• For more information refer to page 78

Fluke 9040Phase Rotation Indicator

Haefely 2293 Automatic Transformer Winding Analyzer

• For more information refer to page 114 or 119

• For more information refer to page 82

Electrical Test Instruments ETI ACDC-10AC and DC Power Supply

N e w I nve n t o r y

• For more information refer to page 64

Megger SPI225Smart Primary Injection Test System

• For more information refer to page 84

Seaward PV150Solar Installation Tester

• For more information refer to page 66

Siemens TD500Secondary Injection Test Set

• For more information refer to page 28

RH Systems 973-SF6Gas Analyzer

• For more information refer to pages 33, 49, 111 or 115

Omicron CP TD12Capacitance and Power/Dissipation Factor Module

NEW INVENTORY

• For more information refer to page 84

Seaward Solar Utility ProComplete Solar Testing Kit

N e w I nve n t o r y

N e w I nve n t o r y

NEW INVENTORY

• For more information refer to page 117

Vanguard TRF-250AThree-Phase Transformer Turns Ratio Meter

• For more information refer to page 20 or 89

Sonel UV-260Corona Camera

TA B L E O F C O N T E N T SBattery Test Equipment ..................................................................................................................................... 1Battery Ground Fault .................................................................................................................................................................................................................. 1

Battery Hydrometers .................................................................................................................................................................................................................. 2

Battery Impedance ....................................................................................................................................................................................................................... 3

Battery Load Units ........................................................................................................................................................................................................................ 4

Battery Voltage Monitors .......................................................................................................................................................................................................... 5

Cable & Bus Test Equipment ............................................................................................................................ 7Cable Fault Locating Test Sets ................................................................................................................................................................................................. 7

Hipotential Test Sets ...................................................................................................................................................................................................................13

Partial Discharge (On-Line) Test Sets ...................................................................................................................................................................................18

Partial Discharge (Off-Line) Test Sets ..................................................................................................................................................................................20

Tan Delta Test Sets .......................................................................................................................................................................................................................21

Electrical Safety ..................................................................................................................................................23

Gas & SF6 Analysis .............................................................................................................................................25

Ground Resistivity ..............................................................................................................................................29

High Voltage Circuit Breaker & Substation ...............................................................................................35Capacitance & Inductance Test Sets .....................................................................................................................................................................................35

Circuit Breaker Timing Test Sets ............................................................................................................................................................................................36

Digital Low Resistance Ohmmeters .....................................................................................................................................................................................38

Hipotential Test Sets ...................................................................................................................................................................................................................42

Power Factor Test Sets...............................................................................................................................................................................................................47

Recloser Control Test Sets........................................................................................................................................................................................................50

Transducer Test Sets ...................................................................................................................................................................................................................51

Low/Medium Voltage Circuit Breakers & Switchgear............................................................................53Digital Low Resistance Ohmmeters .....................................................................................................................................................................................53

High Current Test Sets ...............................................................................................................................................................................................................57

Insulation Resistance Test Sets ...............................................................................................................................................................................................63

Primary Current Injection Test Sets .....................................................................................................................................................................................64

Secondary Current Injection Test Sets ................................................................................................................................................................................65

Vacuum Bottle Test Sets ............................................................................................................................................................................................................68

Meters & Instrumentation ...............................................................................................................................71Borescopes......................................................................................................................................................................................................................................71

Capacitance & Inductance Meters ........................................................................................................................................................................................72

Decade Boxes .................................................................................................................................................................................................................................73

Dew Point & Humidity Analyzers ..........................................................................................................................................................................................74

Dry Block Calibrators .................................................................................................................................................................................................................75

Infrared Survey ..............................................................................................................................................................................................................................76

Motor & Semiconductor Analyzers .......................................................................................................................................................................................78

Multifunction Multimeters .......................................................................................................................................................................................................81

Power Supplies ..............................................................................................................................................................................................................................82

Photovoltaic / Solar Monitoring .............................................................................................................................................................................................84

Watthour Meters .........................................................................................................................................................................................................................85

TABLE OF CONTENTS

Partial Discharge ................................................................................................................................................87Off-Line Test Sets .........................................................................................................................................................................................................................87

On-Line Test Sets ..........................................................................................................................................................................................................................88

Power Quality ......................................................................................................................................................91Data Acquisition ...........................................................................................................................................................................................................................91

Power Quality Analyzers ..........................................................................................................................................................................................................92

Relay & Protection .............................................................................................................................................99Communications Analyzers .....................................................................................................................................................................................................99

Single-Phase Test Sets ...............................................................................................................................................................................................................100

Three-Phase Test Sets ...............................................................................................................................................................................................................101

Transformer Test & Diagnostics ....................................................................................................................105Current Transformer (CT) Test Sets .....................................................................................................................................................................................105

Oil Test Equipment .....................................................................................................................................................................................................................108

Power Factor Test Sets..............................................................................................................................................................................................................109

Sweep Frequency Response Analyzers ..............................................................................................................................................................................112

Turns Ratio Test Sets ..................................................................................................................................................................................................................114

Winding Resistance Test Sets .................................................................................................................................................................................................119

TABLE OF CONTENTS

1(866) 352-5550 | protecequip.com

B AT T E R Y T E S T E Q U I P M E N T

Batteries are an integral part in electrical power systems. They serve a critical role in supplying electricity for power system protection and control circuits in standby applications, as well as backup power for systems that require uninterrupted power. Batteries are often taken for granted while everything appears to be working normally, or as expected. However, it’s when things go unexpectedly wrong that batteries are called into action. If at that time they are unable to perform, the affected circuits could suffer extensive damage and may also disturb the operation of other electrical systems. This is the reason that entities such as N.E.R.C. can legally enforce battery testing standards in the electrical power industry. The type of testing and frequency at which it is performed will be dependent on the electro-chemical make-up of the batteries. Regularly scheduled battery testing and maintenance can provide a confidence in the reliability of our battery systems. Protec maintains an inventory of battery test equipment for all your battery testing needs.

B a t t e r y G r o u n d F a u l t

Megger BGFT

• Identifies and locates ground faults in ungrounded DC systems

• Operates in energized systems

• Optional bridge measurement of fault resistance (from 1 kΩ to 399 kΩ)

• Soft-start charging system prevents sensitive relay tripping

Megger BGFTBattery Ground Fault Tracer

Megger BGL

• Allows tracking and locating of ground faults on live or dead battery systems

• Operates on systems that are either floating or grounded through a resistor

• Operates in the presence of surge-correction capacitors

• Designed to work on battery systems up to 260V DC

Megger BGLBattery Ground Fault Locator

BATTERY TEST EQUIPMENT | BATTERY GROUND FAULT

2 (866) 352-5550 | protecequip.com

BATTERY TEST EQUIPMENT | BATTERY HYDROMETERS

Alber DMA-35-CRT

• Measures and samples density and concentration

• DMA-35-CRT model integrates with Alber CRT-400 for comprehensive reporting through Alber battery analysis software

• Robust and reliable system

Alber DMA-35-CRTHydrometer with Data Logging

Storage Battery Systems SBS-2003

• Automatic temperature compensates to 77º F (25º C)

• Capability of field calibration using distilled water

• Automatically compensates specific gravity for fluid temperature

• IP64 water resistant and for lead-acid batteries only

Storage Battery Systems SBS-2003Battery Hydrometer/Density Meter

Storage Battery Systems SBS-3500

• Stores up to 100 sample IDs for easy sample identification

• Easy and fast replacement of entire pump assembly

• Measures specific gravity and temperature

• Suitable for both lead-acid and nickel-cadmium batteries

Storage Battery Systems SBS-3500Battery Hydrometer/Density Meter

B a t t e r y H yd r o m e t e r s

3(866) 352-5550 | protecequip.com

BATTERY TEST EQUIPMENT | BATTERY IMPEDANCE

Megger BITE2P

• On-line testing requiring no downtime

• Enhanced printing and memory functions

• Measures impedance and DC voltage values for all lead-acid and nickel-cadmium cells up to 7,000Ah

• Stores more than 2,000 sets of readings in up to 300 tests

Megger BITE2PBattery Impedance Test Set

Megger BITE3

• Calculates impedance automatically and stores results for on-site review to make immediate decisions

• On-line testing requiring no downtime

• Stores more than 1 million cells’ data in any string configuration

• Download results to PowerDB software for quick and easy analysis

Megger BITE3Battery Impedance Test Set

Alber CellcorderCRT-400

• Measurement and results not affected by ripple (AC noise), natural battery capacitance or the magnitude of test current

• Measures and records cell voltage, internal battery resistance and intercell resistance

• Internal resistance measurements detect failing cells before failure

• Test battery cells from 0 to 16V

Alber Cellcorder CRT-400Cell Resistance Tester

B a t t e r y I m p e d a n c e

4 (866) 352-5550 | protecequip.com

Megger TORKEL 860

• Ideal for battery discharge analysis in switchgear batteries and similar

• Provided by Protec as a complete system with Megger BVM600; all required cabling and current probes with a preconfigured laptop computer with PowerDB

• User adjustable voltage for 12V to 250V applications

• Single unit loads to 110A, expandable with additional TORKEL 860s or TORKEL TXL870s

• Combine other load bank systems with the Megger XA-12990 Current Probe for total load monitoring and trending

Megger TORKEL 860Battery Load Unit

Megger TORKEL 950

Megger TORKEL 950Battery Load Unit

• Ideal for battery discharge analysis in switchgear batteries and similar

• Provided by Protec as a complete system with Megger BVM600; all required cabling and current probes with a preconfigured laptop computer with PowerDB

• User adjustable voltage for systems up to 500V DC

• High discharge capacity allows for shortened test times

• Single unit loads to 220A, expandable with additional TORKEL 950s or TXL units

BATTERY TEST EQUIPMENT | BATTERY LOAD UNITS

Storage Battery Systems SBS-8400Battery Capacity Tester

• Provided by Protec as a complete system with wireless BVM clamps

• User selectable discharge mode: constant current/power/resistance

• User adjustable voltage for 10V to 300V

• Single unit loads to 120A, can be paralleled with other load banks to increase draw up to 600A

• Four adjustable stop points and multiple alarm designs to intelligently control the discharge process

Storage Battery SystemsSBS-8400

8400-600A DC battery voltage monitor clamps available for

SBS units

B a t t e r y Lo a d U n i t s

5(866) 352-5550 | protecequip.com

BATTERY TEST EQUIPMENT | BATTERY VOLTAGE MONITORS

Megger BVM-300/600

• Used in conjunction with a load device, such as the TORKEL unit, and test data management software, such as PowerDB Lite

• Daisy-chain design allows expandability up to 120 batteries

• Wide voltage range of 0 to 5V or 0 to 20V DC per BVM

• Each unit is identical, eliminating complex battery connection charts and connecting multiple leads to individual battery terminals

Megger BVM-300/600Battery Voltage Monitor

B a t t e r y Vo l t a g e M o n i t o r s

6 (866) 352-5550 | protecequip.com

7(866) 352-5550 | protecequip.com

C A B L E & B U S T E S T E Q U I P M E N T

Overvoltage protection is critical to the long-term health of electrical power system components. It has a significant relationship to the electrical insulation that is integral to the construction of various items which make up the electrical power system. Dielectric test sets (High Potential) measure leakage current while applying a voltage at or above the insulation system’s operating level. Because it tends to be smaller, lighter and more portable than equivalent AC (50/60Hz) test equipment, DC high potential test sets have historically been preferred for field testing applications. However, as the industry has gained a better understanding of insulating materials and the impacts of our testing, it has been determined that DC dielectric testing is not always the best choice for every application. When in their normal in-service condition, the insulating materials that make up such a large part of our power system are being subjected to AC stresses. Therefore, it has become preferable to employ VLF (0.1Hz) (Very Low Frequency) technologies that are more practical for some field-testing applications. Testing at lower frequencies has enabled the use of more portable test equipment than what would be possible at power system frequencies. Additionally, the application of VLF technology has enabled the industry to utilize diagnostic tools such as Partial Discharge (PD) and Tangent Delta (TD) testing as predictive indicators regarding degradation of insulation and replacement planning in cable testing applications. In addition to cable tracing and fault locating test equipment, PD and TD testing are a valuable complement to a cable testing tool kit. Protec carries an inventory of test equipment for all your cable and bus testing needs.

CABLE & BUS TEST EQUIPMENT | CABLE FAULT LOCATING TEST SETS

C a b l e F a u l t Lo c a t i n g Te s t S e t s

Amprobe AT-3000

• Indicates the depth of the traced object

• Allows pinpointing the traced object

• Three locating modes

y Power

y Radio

y Transmitter

• Indicates strength of signal

• Convenient in noisy environments

Amprobe AT-3000Underground Cable Locator

8 (866) 352-5550 | protecequip.com

CABLE & BUS TEST EQUIPMENT | CABLE FAULT LOCATING TEST SETS

Amprobe AT-7030

• Comprehensive kit includes all required components for tracing low voltage circuits in walls, ceilings, floors and corners

• Innovative new antenna design and advanced signal processor provides the exact location and orientation of wires/circuits

• Effective in both energized and de-energized applications

• Locates breakers and fuses

• Pinpoints shorts and opens

• High resolution color LCD displays active process and menu

Amprobe AT-7030Advanced Wire Tracer Kit

Aqua-Tronics EG 3000/ EG 3000 T

• Used to locate all unshielded cable faults and sheath-to-ground faults

• Can produce up to 3,000 volts of signal

• Will not place any more voltage on the cable than is required to flash the fault

• Battery powered, and comes with a car charger for charging on the go

• Can be used in almost any type of weather or operating conditions

• EG 3000T unit adds cable tracing functionality

Aqua-Tronics EG 3000/EG 3000 TSecondary Cable Fault Locator

Aqua-Tronics S.D.A.D.

• Excellent companion to CDS-2010 or VON XF25 for audible confirmation of fault location

• Two channel system enables directional fault indication

• Bright backlit screen indicates distance to fault and fault depth

• Includes stirrup probes for hard surfaces

• Fault centering function quickly orients user to fault location

• Simple operation for less familiar users

Aqua-Tronics S.D.A.D.Acoustic Fault Detector

C a b l e F a u l t Lo c a t i n g Te s t S e t s

9(866) 352-5550 | protecequip.com

CABLE & BUS TEST EQUIPMENT | CABLE FAULT LOCATING TEST SETS

C a b l e F a u l t Lo c a t i n g Te s t S e t s

High Voltage TDR1669

• Connects to thumper via standard BNC cable

• Low voltage TDR mode enables cable end identification and velocity factor adjustment

• On-board memory of 15 traces

• Dual-trace overlays previous results

• Measures cable ends to 48,000 ft

• Zooms to 4x on 3,000 ft range for precise event examination

High Voltage TDR1669Time Domain Reflectometer

HV DiagnosticsEZ-Cable ID

• Designed to avoid live cable cut-ins

• Accurately and effectively identifies either single or three-phase cables anywhere (simultaneously) along the length of the cable

• Effective for use on single or multi-conductor cable

• Works in energized and de-energized applications, including high load-carrying conductors

• Available as a complete kit with receiver, transmitter and user’s choice of inductive clamp(s) or flexible coils

HV Diagnostics EZ-Cable IDSingle/Three-Phase Cable and Phasing Identification System

Fluke NetworksOptiFiber Pro Series 2

Fluke Networks OptiFiber Pro Series 2Optical Time Domain Reflectometer (OTDR)

• Full OTDR capability that certifies fiber performance based on industry standards or customer specifications

• Compliant with ISO and TIA standards

• Reduce network downtime by quickly and precisely identifying faults on all fiber types

• Taptive user interface puts advanced data analysis, easy set-up and operation at the fingertips of technicians of all skill levels

• Test times as short as two seconds in quick test mode

10 (866) 352-5550 | protecequip.com

CABLE & BUS TEST EQUIPMENT | CABLE FAULT LOCATING TEST SETS

Megger L1050

• Rugged, durable built to withstand the rigors of day-to-day field use

• One-piece design that is lightweight and highly accurate

• Picks up the signal at waist height, thus eliminating the need for awkward bending

• Four types of locating methods

• Operates at multiple frequencies from 815Hz to 82.315kHz

Megger L1050Portable Cable Fault Locator

IUP Fault Wizard

• Single piece high voltage thumper, ARC reflection TDR, DC hipot and low voltage TDR

• Simplified transportation through common express carriers

• Ideal for testing up to 15kV shielded cable

• Locates faults to 10,000 ft (maximum capacitance of 7uF)

• Variable impulse voltage (thump) for minimal cable damage

• Variable velocity of propagation for precision adjustment to specific application

IUP Fault WizardCable Fault Locator

Megger CFL535G

• Dual channel system measures two cables (or two conductors) simultaneously

• Xpert mode evaluates cable under test and adjusts to ideal settings

• One press of the XPert button identifies the first major event on the cable

• Second pulse function identifies near (test) end faults

• Manual control permits fine settings adjustments and full user control

• Dual trace and dual cursors immediately identify distances

Megger CFL535GAdvanced Dual Channel TDR

C a b l e F a u l t Lo c a t i n g Te s t S e t s

11(866) 352-5550 | protecequip.com

CABLE & BUS TEST EQUIPMENT | CABLE FAULT LOCATING TEST SETS

Megger PFL22M1500

• Portable, rugged fault locating system

• HV insulation testing up to 20kV

• 8/16kV, 1,500 Joules surge output

• Multiple fault locating techniques

y Pre-location

y Pulse echo

y Arc reflection

y Arc reflection plus

y Differential arc reflection

y Impulse current

Megger PFL22M1500Portable Cable Fault Location System

Megger PFL40A

• Portable, rugged fault locating system

• HV insulation testing up to 40kV

• 8/16/34kV, 2,000 or 1,500 Joules surge output

• Multiple fault locating techniques:

y Pre-location

y Pulse echo

y Arc reflection plus

y Differential arc reflection

y Impulse current

y Voltage decay

Megger PFL40APortable Cable Fault Location System

C a b l e F a u l t Lo c a t i n g Te s t S e t s

Megger SG32-1500M

y HV insulation testing up to 32kV

y 16/32kV, 1,500 Joules surge output

y Multiple fault locating techniques

y Pre-location

y Pinpoint

y High-voltage module

Megger SG32-1500MPortable Fault Location System

12 (866) 352-5550 | protecequip.com

CABLE & BUS TEST EQUIPMENT | CABLE FAULT LOCATING TEST SETS

VON XF28-1960

• Very high output power – 1960 Joules

• 120V line powered or battery operated with on-board battery charger

• Ideal for use on 35kV cables

• On-board TDR (cable radar) automatically marks end of cable and fault location(s) with distances

• A total fault location solution when paired with the Aqua-Tronics S.D.A.D.

VON XF28-1960Portable Arc Reflection Combination TDR Thumper

C a b l e F a u l t Lo c a t i n g Te s t S e t s

13(866) 352-5550 | protecequip.com

CABLE & BUS TEST EQUIPMENT | HIPOTENTIAL TEST SETS

H i p o t e n t i a l Te s t S e t s

High Voltage ALT-120/60

• Side tap at 60kV provides 115mA capacity

• Top tap at 120kV provides 58mA capacity

• 120V / 25A input

• Ideal for ISO phase bus testing, aerial lift devices and elevated platforms, most common dielectric withstand tests, and as a source voltage for apparatus PD testing

• Not suitable for cable testing

High Voltage ALT-120/6060kV and 120kV Power Frequency AC Hipot

High Voltage PFT-301CM

• Convenient one-piece field portable design

• Primary connected single range voltmeter: 0 to 30 kV AC

• Single range current meter: 0 to 40 mA AC

• Transit protected meters prevent meter damage between test sites

• 20 ft shielded output and return cables

High Voltage PFT-301CM30kV Power Frequency AC Hipot

High Voltage PFT-303

• Convenient one-piece field portable design

• Secondary connected 2 range voltmeter: 0 to 15 / 30kV AC

• 3 range current meter: 0 to 1mA AC with x1, x10, and x100 multipliers

• 20 ft shielded output and return cables

• Gapped core transformer design for capacitive load compensation

High Voltage PFT-30330kV Power Frequency AC Hipot

14 (866) 352-5550 | protecequip.com

CABLE & BUS TEST EQUIPMENT | HIPOTENTIAL TEST SETS

H i p o t e n t i a l Te s t S e t s

High Voltage PTS-75/PTS-80

• 5 range current/megohm meter for accurate leakage current

• Megohm readings at any output voltage up to 7.5 / 8 teraohms

• Full-wave bridge rectifier

• Internal HV Shorting Solenoid with discharge resistors

• Automatic transit protected meters with anti-static glass face

High Voltage PTS-75/PTS-8075kV and 80kV DC High Voltage Test Set and Megohmmeter

High Voltage PFT-503CM

• Convenient one-piece field portable design

• Secondary connected 2 range voltmeter: 0 to 15 / 30kV AC

• 3 range current meter: 0 to 1mA AC with x1, x10, and x100 multipliers

• Guard/ground circuit for accurate leakage current measurement

• Gapped core transformer design for capacitive load compensation

High Voltage PFT-503CM50kV Power Frequency AC Hipot

High Voltage PFT-652CM

• Convenient two-piece field portable design

• Secondary connected 2 range voltmeter: 0 to 32.5 / 65kV AC

• 3 range current meter: 0 to 1mA AC with x1, x10, and x100 multipliers

• Transit protected meters prevent meter damage between test sites

• Guard/ground circuit for accurate leakage current measurement

High Voltage PFT-652CM65kV Power Frequency AC Hipot

15(866) 352-5550 | protecequip.com

CABLE & BUS TEST EQUIPMENT | HIPOTENTIAL TEST SETS

H i p o t e n t i a l Te s t S e t s

High VoltageVLF-4022CM

• Output voltage is 40kV peak at 5.5mA max

• Adjustable output frequency of 0.1Hz, 0.05Hz, or 0.02Hz (sinusoidal)

• Capable of testing 35kV cable up to a maximum distance of 10 miles

• Metering includes voltmeter ±0 to 60k VAC peak charging current meter

• 0 to 100mA peak, and load capacitance meter 0 to 6μF

• Two piece design; controller is approximately 75 lbs and the high voltage tank is approximately 120 lbs

High Voltage VLF-4022CM40kV High Load Capacity Portable VLF Hipot

High Voltage PTS-200

• 200kV output voltage at 5mA

• Continuously adjustable output voltage

• High voltage tank is approximately 150 lbs, controller is approximately 35 lbs

• Dual range voltage meter scaled 0 to 80/200

• Microamp and megohm meter scales for both leakage current and resistance measurements

High Voltage PTS-200200kV DC Hipot and Megohmmeter

High Voltage PTS-130

• 130kV output voltage at 10mA

• Continuously adjustable output voltage

• Functional two piece design

• High voltage tank is approximately 82 lbs, controller is approximately 35 lbs

• Dual range voltage meter scaled 0 to 70/130

High Voltage PTS-130130kV DC Hipot and Megohmmeter

16 (866) 352-5550 | protecequip.com

CABLE & BUS TEST EQUIPMENT | HIPOTENTIAL TEST SETS

H i p o t e n t i a l Te s t S e t s

HV Diagnostics PDTD60/PDTD120

• 60kV / 120kV VLF output voltage

• 120V input voltage

• 2 piece unit

• Suitable for 69kV cable (PDTD60) and 35kV cable (PDTD120)

• Total weight 347 lbs (PDTD60) and 90 lbs (PDTD120)

HV Diagnostics PDTD60/PDTD12060kV and 120kV Partial Discharge and Tan Delta System

Phenix 6CP100/50-10

• Ideal high voltage source for PD measurements using the ICM Flex for off-line partial discharge apparatus testing; not suitable for cable testing

• Minimal partial discharge – less than 4pC at 100kV and less than 3pC at 80kV

• Two-piece design with hand truck mount for controller and tank improves portability

• Side tap at 50kV provides 200mA capacity; top tap at 100kV provides 100mA capacity

• 230V input, and adjustable overload circuit

Phenix 6CP100/50-1050kV & 100kV AC Dielectric Test Set

• 34kV / 65kV output voltage

• 120V input voltage

• Adjustable output frequency

• 5μF load @ 0.02Hz

High Voltage VLF-34E/VLF-65E34kV/65kV VLF Hipot

High VoltageVLF-34E/VLF-65E

17(866) 352-5550 | protecequip.com

CABLE & BUS TEST EQUIPMENT | HIPOTENTIAL TEST SETS

H i p o t e n t i a l Te s t S e t s

• Compact, single-piece construction for improved portability and logistics compared to AC or DC hipots with similar cable testing capability

• Simple and intuitive menu driven user interface

• Consistent controls, menus and connections on each model ensures minimal learning curve from instrument to instrument

• Appropriate for testing cables, capacitors, switchgear, transformers, rotating equipment, insulators and bushings

• Meets requirements of a Type I withstand testing according to IEEE 400.2 and other national and international standards

• User specified or automatically adjusted output frequency according to measured capacitance (1Hz to 0.01Hz in 0.01Hz steps)

• Sinusoidal, cosine rectangular, or DC output waveform

• True symmetrical sinusoidal, load independent output waveforms across full load range

• Short circuit protection with active arc management

• Digital metering displays voltage (RMS or Peak), capacitance, resistance, elapsed time, and flashover voltage

• Storage of test results and test sequences (test plans) in internal memory and on-board USB port for USB flash drive

• HVA control center software produces professional reports

• Keyed safety interlock and emergency shutdown

• Seamless integration with HV Diagnostics tan delta measurement systems, HV diagnostics partial discharge analysis equipment and Power Diagnostix ICMFlex

• HVA28TD model adds on-board tan delta measurement system

HVA Model Peak Voltage RMS Voltage Acceptance Maintenance

HVA28TD 28kV 20kV Up to 15kV Up to 20kV

HVA30 30kV 22kV Up to 16kV Up to 22kV

HVA34 34kV 24kV Up to 15kV Up to 25kV

HVA34TD 34kV 24kV Up to 15kV Up to 25kV

HVA45TD 45kV 32kV Up to 25kV Up to 30kV

HVA60 60kV 44kV Up to 35kV Up to 46kV

HVA90 90kV 64kV Up to 46kV Up to 69kV

HVA120 120kV 85kV Up to 69kV Up to 69kV

HV Diagnostics HVA VLF/DC High Voltage Test Sets28kV, 30kV, 34kV, 45kV, 60kV, 90kV and 120kV Hipots for VLF Withstand Testing, Tan Delta (Dissipation Factor) and Off-Line Partial Discharge Cable Testing

HV Diagnostics HVA28TD

HV Diagnostics HVA34

HV Diagnostics HVA120

18 (866) 352-5550 | protecequip.com

CABLE & BUS TEST EQUIPMENT | PARTIAL DISCHARGE (ON-LINE) TEST SETS

Pa r t i a l D i s c h a r g e (O n - L i n e) Te s t S e t s

EA Technology CableData Collector

• Identifies and allows you to report on PD activity in live MV/HV cable networks

• Detects and measures PD activity in single and three-phase cables

• Works with all insulated cable types

• Quick assessment of a large number of cables to build up a total view of the condition of a distribution cable network

• Quickly highlights cables that require more detailed analysis techniques

EA Technology CableData CollectorPartial Discharge Analyzer

EA TechnologyUltraTEV Plus2

• Quickly identify presence and severity of PD in electrical apparatus

• Baselines PD activity to direct maintenance activities

• Measures surface PD as numerical dB values and measures internal partial discharge as Transient Earth Voltages (TEV) values

• Automatically grades condition of TEV and ultrasonic values for immediate analysis

EA Technology UltraTEV Plus2Multifunction Partial Discharge Analyzer

Ofil Systems DayCor Superb-OD

• Accurately pinpoints sources of corona, partial discharge, micro arcing and arcing that may lead to audio noise, radio/TV interference and electrical mechanical failures

• An anatomically form-fitted harness distributes the camera’s weight and allows extended inspection intervals

• Built-in recording, playback and storing of high-resolution video clips with voice annotations and still pictures

• Bi-spectral solar blind UV-visible camera allowing operation in full daylight

Ofil Systems DayCor Superb-ODCorona Camera

19(866) 352-5550 | protecequip.com

CABLE & BUS TEST EQUIPMENT | PARTIAL DISCHARGE (ON-LINE) TEST SETS

• One instrument solution for a wide variety of substation apparatus and cables

• Represents the latest technology in both electromagnetic and acoustical sensors to identify and find PD in energized substations and switchgear

• Available with Ultra High Frequency (UHF), Transient Earth Voltage (TEV), High Frequency CT (HFCT or RFCT), acoustical contact, airborne acoustic sensors

• Sensors are wireless where appropriate so operator can maintain safe approach distances

• Hand-held instrument is small, lightweight and portable

• Short learning curve – operators can become proficient in minutes

• Instrument identifies specific PD type: void, corona, surface, particle or floating electrode

• Phase resolved display documents PD over the sine wave to ensure measured PD is from the circuit under test and not background or nominal noise

• PRPD (2D) and PRPS (3D) compare UHF and HFCT signals to local power signal

• AE and ultrasonic values displayed as RMS, peak, frequency content (x1 and x2), phase, pulse and wave spectrum

• Wireless line synchronization is accomplished wirelessly using the instrument charger

• Suitable for use on power cables, transformers, GIS, switchgear and other substation apparatus

• Available with PDetector software to catalog and trend results and produce professional reports

• Programmable alarms document exact PD signature so reports are clear to those unfamiliar with PD testing

• Software exports results to Excel or PDF

• On-board RFID asset tagging and intelligent patrol functions automatically document the specific substation assets being tested

PMDT PDetectorHandheld Partial Discharge Detector

Pa r t i a l D i s c h a r g e (O n - L i n e) Te s t S e t s

PMDT PDetector

Sonel UV-260Corona Camera

20 (866) 352-5550 | protecequip.com

CABLE & BUS TEST EQUIPMENT | PARTIAL DISCHARGE (ON-LINE / OFF-LINE) TEST SETS

Sonel UV-260

• High sensitivity to UV signals

• Precise location of corona-emitting sources

• UV events alarm and counter

• Still image capture and review

• Built-in GPS documents test location

• UV-260 PC software for reports

Pa r t i a l D i s c h a r g e (O n - L i n e) Te s t S e t s

Pa r t i a l D i s c h a r g e (O f f - L i n e) Te s t S e t s

HV Diagnostics High Voltage Sourcesfor Off-Line PD Analysis

ModelOutput Volt-

ageInput Pieces

Total Weight

TypicalApplication

HVA34 34kV VLF 120V 1 44 Lbs 15kV Cable

HVA60 60kV VLF 120V 1 126 Lbs 35kV Cable

HVA90 90kV VLF 120V 1 280 Lbs 46kV Cable

HVA120 120kV VLF 240V 1 436 Lbs 69kV Cable

PDTD60 60kV VLF 120V 2 347 Lbs 69kV Cable

PDTD120 120kV VLF 120V 2 90 Lbs 35kV Cable

HV Diagnostics PDTD120

21(866) 352-5550 | protecequip.com

CABLE & BUS TEST EQUIPMENT | TAN DELTA TEST SETS

• High voltage tan delta measurement system for testing XLPE, PE, EPR, PILC, etc.

• Provides Type II diagnostic testing and meets requirements of IEEE 400.2 and other national and international standard

• Capable of working with many VLF AC instruments

• Full report generating software

• Compact and battery operated

• Simple and convenient setup

• Solid state, air insulated design

• Wireless data transmission via Bluetooth

• Protec provides TD Control Center software, which displays individual voltage/waveform, loss angle data and plots tan delta curve

• Real time display of actual waveform output and data

• Visual indication of PD levels with LED indicators

Manufacturer Model Peak Voltage RMS Voltage Weight Dimensions (LxW)

HV Diagnostics TD30 30kV 1 to 23kV 7 Lbs 9.5" x 3.5"

High Voltage TD-34E 36kV 1 to 25kV 7 Lbs 9.5" x 3.5"

HV Diagnostics TD60 60kV 1 to 44kV 11 Lbs 18" x 5"

HV Diagnostics TD60-MC 62kV 1 to 44kV 11 Lbs 26" x 5"

HV Diagnostics TD90-MC 90kV 1 to 64kV 24 Lbs 26" x 5"

Ta n D e l t a Te s t S e t s

HV Diagnostics Tan Delta Measurement Systems 30kV, 60kV, 62kV and 90kV Tan Delta (Dissipation Factor) Test Systems

High Voltage Tan Delta Measurement Systems 36kV and 60kV Tan Delta (Dissipation Factor) Test Systems

High Voltage TD-34E

HV Diagnostics TD60-MC

22 (866) 352-5550 | protecequip.com

23(866) 352-5550 | protecequip.com

ELECTRICAL SAFETY

E L E C T R I C A L S A F E T Y

Electrical current exposes workers to a serious, widespread workplace hazard. Many workers are exposed to electrical energy while completing their daily responsibilities, and many are unaware of the potential electrical hazards present in their work environment, making them more vulnerable to the danger of electrocution. A variety of possible solutions may be implemented to reduce or eliminate the risk of injury associated with electrical work. Examples of solutions include the use of insulation, guarding, grounding, electrical protective devices and safe work practices. Protec carries and inventory of test equipment for all your electrical safety needs.

AEMC 275HVD

• Works on unshielded cables only

• Range of detection: 80V to 275kV

• Eight switch selectable voltage sensitivity ranges

• Audible and visual indication of live voltage

• Designed for use with hot sticks incorporating a shotgun adapter

• Powered by three standard alkaline C cell batteries

AEMC 275HVDNon-Contact Voltage Detector

Bender LT3000

• Tests line isolation monitors and ground fault circuit interrupters

• Operates on system voltages from 100VAC to 240VAC

• Large LCD display

• Overload protection with automatic reset

• System leakage measurements

• Twist-to-lock adapter

Bender LT3000Line Isolation Monitor

24 (866) 352-5550 | protecequip.com

ELECTRICAL SAFETY

E l e c t r i c a l S a f e t y

Ground Cluster

• Typical 15 ft 4/0 cables with connections for A phase, B phase, C phase and ground

• Clamps adjustable with a hook type hotstick

• Available with duckbill clamps

Ground ClusterAvailable in Multiple Configurations

RKI GX-2009

• Simultaneous detection of LEL, O2, H2S, and CO

• Smallest/lightest four gas monitor on the market

• Three visual alarms and a vibration alarm

• IP-67 water-resistant design

• Up to 20 hours of operation

RKI GX-2009Gas Detector

25(866) 352-5550 | protecequip.com

GAS & SF6 ANALYSIS

G A S & S F 6 A N A LY S I S

Electrical insulation serves a critical role as it relates to the safe transmission and distribution of electricity. These insulating materials often become an integral part of electrical apparatus and can be dependent on a variety of criteria including voltage level, insulating qualities, physical restrictions and the application of the electrical apparatus being considered. In high voltage applications sulfur hexafluoride (SF6) is an inorganic, non-flammable, non-toxic gas that is an excellent electrical insulator. However, the purity of the gas becomes critical concern for applications in high voltage insulation. If the purity of the gas becomes compromised, then the entire circuit can be at risk in addition to it becoming a safety concern for anyone in close proximity to the circuit if the insulation were to fail. The importance of monitoring the purity of this gas becomes clearer as we consider the potential decomposition of the gas due to exposure to high energy faults as well as the ingress of contaminants (such as moisture) into the insulating system. A regular testing and maintenance program of power system apparatus that utilize gas as an insulating medium would have to include tests that help to ensure that the gas is free of degradation or contamination. Protec maintains an inventory of gas and SF6 analysis equipment for all your needs.

DILO 3-027-R002

• Simple operation and logical controls

• Indicates SF6 volume percentage (SF6 purity by volume) independent of atmospheric pressure and location

• Accuracy of +/- 1% by volume for 0-100% SF6 in SF6/N2

• Available with DN20/DN8 self-sealing couplings and DILO coupling DN20

DILO 3-027-R002SF6 Volume Percentage (Purity) Analyzer

DILO 3-033-R002LeakPointer

• Handheld

• Automatic switching over to levels of sensitivity

• Detection of SF6 leaks up to 5g/year

• Battery-operated

DILO 3-033-R002 LeakPointerSF6 Leak Detector

26 (866) 352-5550 | protecequip.com

GAS & SF6 ANALYSIS

DILO 3-038R-R303

• Determines SF6 moisture content, purity (density) and SO2

• Intuitive menu driven interface steps operator through testing with touchscreen control

• On-board SF6 storage vessel and pump back to test specimen ensures zero emissions operation

• Stores data for later review on the instrument or download to a USB port and user adjustable limit values

• Available with a DILO SF6 Analyzer Adaptor Kit

DILO 3-038R-R303SF6 Analyzer with Recirculation

DILO 3-033-R200LeakSpy

• Detection of SF6 leakages up to 3g/year

• No cross sensitivity to moisture and most volatile organic compounds (VOCs)

• A shoulder belt facilitates mobile and ergonomic working

• Battery-operated with life of 12 hours

DILO 3-033-R200 LeakSpySF6 Leak Detector

G a s & S F 6 A n a l y s i s

DILO 3-038-R032 NP

• Determines SF6 and CF4 moisture content, purity (density) and SO2

• Quick test results, less than seven minutes typical

• Gas outlet allows for collection of exhaust gases for emissions-free testing and portable and lightweight bench top configuration

• Stores data for later review on the instrument or download to a USB port and user adjustable limit values

• Available with a DILO SF6 Analyzer Adaptor Kit

DILO 3-038-R032 NPSF6 and CF4 Analyzer

27(866) 352-5550 | protecequip.com

GAS & SF6 ANALYSIS

DILO SF6 AnalyzerAdapter Kit

• Everything required to connect an SF6 analyzer to your apparatus

• Includes:

y SF6 regulator assembly

y SN8 self-sealing male to 3/8” male NPT

y 1/4” FJIC

y 3/8” JFIC

y Siemens Aeroquip/SPS

y DN20 self-sealing male to 1-1/4” parker (ITE, Westinghouse, ABB PA)

y DN20 self-sealing male to 3/8” female NPT

y DN80 self-sealing male to 1” male NPT

y DN20 self-sealing male to malmquist (ABB PM)

DILO SF6 Analyzer Adapter KitRegulator, Fitting and Adapter Kit for SF6 Analysis

DILO SF6 HB 120A(Blanket Only)

• Power: 500W

• Velcro retention strap

• Thermostatic safety controlled

• Maximum temperature capability will not affect SF6

• Dimensions: 28" x 10"

DILO SF6 HB 120ACylinder Heating Blanket

G a s & S F 6 A n a l y s i s

Fluke Ti450

• Detects and pinpoints the exact location of the SF6 leak

• Quick entry/exit button allowing quick toggling between gas imaging and infrared mode

• 320 X 240 resolution for gas images

• Fluke Connect compatibility

Fluke Ti450SF6 Gas Detector

28 (866) 352-5550 | protecequip.com

GAS & SF6 ANALYSIS

G a s & S F 6 A n a l y s i s

Wika GA10

• Determines SF6 moisture content, purity (density) and SO2

• Intuitive menu driven interface steps operator through testing

• Stores data for later retrieval on instrument or download to Wika’s SF6 Reviewer software

• Measurement validation in accordance with CIGRE, IEC and other national and international standards

• Available with a DILO SF6 Analyzer Adaptor Kit

Wika GA10SF6 Gas Analyzer

RH Systems 973-SF6

• Specifically designed for measurement of humidity and SF6 purity in gas insulated switchgear systems

• Humidity measurement data is displayed in ppmv, ppmw and dew/frost point at either system pressure or standard pressure

• Purity measurement is displayed directly in % volume SF6

• Both the humidity and purity measurements utilize accurate and reliable condensation techniques

• Equipped with a gas recovery system that stores the sampled gas during the measurement process in its internal storage tank.

• Range: -55°C…+20°C DP, accuracy is 0.5 deg of reading

• Dew/Frost Point results at SF6 compartment or standard pressure

RH Systems 973-SF6Gas Analyzer

29(866) 352-5550 | protecequip.com

GROUND RESISTIVITY

G RO U N D R E S I S T I V I T Y

Transformers are electrical devices consisting of two or more coils of wire used to transfer electrical energy by means of a changing magnetic field. A transformer is basically a very simple static (or stationary) electro-magnetic passive electrical device working on the principle of Faraday’s law of induction by converting electrical energy from one value to another. If maintained and serviced regularly, transformers can be extremely reliable and provide service for long periods of time. That being said, transformers are also the single most costly item in any substation. To protect against failures that can result in costly repairs and long periods of downtime, a proper testing, diagnostic, and maintenance routine is recommended. The best insurance against transformer failure is to ensure that they are preventatively maintained and serviced. Protec provides a complete line of rental equipment for quick and accurate ground resistivity testing and diagnostics.

AEMC 6416

• Measures ground rod and grid resistance without driving temporary ground rods or running leads

• Verifies quality of grounding connections/bonds and continuity of ground loops

• Jaw opening of 1-1/2”

• Provides ground voltage indication and warns of possible unsafe conditions

AEMC 6416Clamp On Ground Resistance Tester

AEMC 3711/3731

• Measure ground rod and grid resistance without driving temporary ground rods

• Verifies quality of grounding connections/bonds and continuity of ground loops

• Jaw opening of 1-1/4”

• AEMC 3731 includes a display hold function

AEMC 3711/3731Clamp On Ground Resistance Test Set

30 (866) 352-5550 | protecequip.com

GROUND RESISTIVITY

G r o u n d R e s i s t i v i t y

Bender LT3000

• Tests line isolation monitors and ground fault circuit interrupters

• Operates on system voltages from 100VAC to 240VAC

• Large LCD display

• Overload protection with automatic reset

• System leakage measurements

• Twist-to-lock adapter

Bender LT3000Line Isolation Monitor

Fluke 1625

• Performs earth ground loop resistances using clamps only (stakeless testing), Fall-of-Potential, earth resistivity, and selective testing (or attached rod technique)

• Automatic frequency control mitigates interference

• Adjustable limits for immediate results verification

• Available as a complete kit with leads current probes, and stakes

Fluke 1625Multifunction Geo Earth Ground Test System

Megger DET2/2

• Ideal for large ground systems or applications requiring long lead runs

• High resolution (1mΩ) and high accuracy

• Performs fall-of-potential, soil resistivity, and point-to-point tests

• User adjustable test voltage to 50V (max)

• User adjustable wideband test frequency to mitigate interference

• Available with ground test kit complete with leads and ground rods

Megger DET2/2Digital Ground Resistance Tester

31(866) 352-5550 | protecequip.com

GROUND RESISTIVITY

G r o u n d R e s i s t i v i t y

Megger DET24C

• Measures ground resistance from 0.05 Ohms to 1,500 Ohms

• Measures true RMS ground leakage current from 0.5mA RMS to 35mA RMS

• Elliptical clamp shape improves access to earth cables and straps up to 50mm

• Automatic self-calibration

• Automatic ranging

• Compatible with PowerDB/PowerDB Lite

Megger DET24CGround Resistance Clamp Tester

Megger DET4TCR2

• Two-point, three-point and four-point testing

• Stakeless (clamp-on) testing capability

• Multiple user selectable test frequencies

• Resistance measurement range to 200,000 Ohms

• Simple one-button operation

• Rechargeable battery powered

Megger DET4TCR24 Terminal Ground Resistance Tester

Megger DET3TC

• Selectable test voltages (25V or 50V)

• 0.01Ω to 2,000Ω range

• Available with leads and temporary ground rods

• Automatic noise check and rejection to 40V peak-to-peak

• Measure leakage current from 0.5mA to 19.9A

• Enables testing of on-site grounds separately without removing utility connection

Megger DET3TC/ICLAMP3 Terminal Ground Resistance Tester

Use with Megger ICLAMPfor attached rod technique

testing

Megger ICLAMP

32 (866) 352-5550 | protecequip.com

GROUND RESISTIVITY

G r o u n d R e s i s t i v i t y

Megger DET62D

• Three terminal measurement for ground electrode testing

• Simple, fully automatic operation

• Rugged weatherproof case

• Large clear LCD screen

• Superior noise rejection to 40V

• High tolerance to spike resistance

Megger DET62DDigital Earth Tester

• Measures line impedance and K-factor on overhead lines and power cables

• Determines ground impedance and touch-and-step potential on large systems

• Available with the GB1 grounding unit to ensure user safety

• Determines true test values by power line injection method

• HGT1 provides simple and accurate touch-and-step potential measurements

• Measures reduction factor on ground wires and cable shields

• Complies with EN 50522 and IEEE 80/81 requirements

• Results unaffected by input power frequency

• Automatically records results with included software

• Couples power lines into signal cables and provides mutual coupling of parallel overhead lines

• Selective frequency measurement and digital filtering ensures laboratory grade accuracy

• Lightweight and one-person portable system

• Intuitive reporting and assessment with dedicated templates

• Available as a complete system including CPC 100 and CP CU1, Rogowski coils, handheld GPS device, GB1 and HGT1

• More CPC-100 accessories available on pages 33, 49 and 111

Omicron CPC 100 / CP CU1Multifunctional Primary Test System

Omicron CP CU1

Omicron CPC 100

33(866) 352-5550 | protecequip.com

Omicron CP TD12

• Includes a high-voltage source, reference capacitor and measurement electronics

• Generates output voltages up to 12kV, currents up to 300mA

• Achieves laboratory precision, even in environments with strong interferences

• Accessory for the Omicron TESTRANO 600, CPC 100 or CPC 80

Omicron CP TD12Capacitance and Power/Dissipation Factor Module

G r o u n d R e s i s t i v i t y

GROUND RESISTIVITY

34 (866) 352-5550 | protecequip.com

35(866) 352-5550 | protecequip.com

HIGH VOLTAGE CIRCUIT BREAKER & SUBSTATION | CAPACITANCE & INDUCTANCE TEST SETS

H I G H VO LTAG E C I RC U I T B R E A K E R &

S U B S TAT I O N

Circuit breakers have historically functioned as the protective muscle of the electrical power system. Their effectiveness in performing their job depends on the unique application, design and operating condition. While protective guardians vary widely regarding design and construction, they continue to share in the basic functionality of conducting or interrupting the flow of electricity. Additionally, their ability to perform these functions in concert with their intended design is subject to mechanical, electrical and environmental impacts. Like an insurance policy that fails to protect, a circuit breaker that does not serve its protective purpose is of little value. When something occurs resulting in unexpected fault conditions, we need to be able to count on circuit breakers to perform as intended. Testing and maintenance program will help to provide confidence that the electrical system is in good health. Protec carries and inventory of test equipment for all your high voltage circuit breaker and sub station testing needs.

C a p a c i t a n c e & I n d u c t a n c e Te s t S e t s

ABB CB-2000

• Compact self-contained capacitor bank analysis

• Permits measurements of individual capacitors without breaking connections

• On-board memory can be transferred to a PC for report generation or data trending and analysis

• Data from PC can be transferred to CB-2000 for on the spot analysis

• Available with large, wide-jaw current probe to accommodate a wide variety of capacitor bushings

ABB CB-2000Portable Capacitance Meter

B&K Precision 885

• Dual LCD display

• Fully automatic/manual selection

• DC resistance measurement

• Measurement parameters: Z, L, C, DCR, ESR, D, Q and q

• Infrared RS-232 interface capability

B&K Precision 885LCR/ESR Meter

36 (866) 352-5550 | protecequip.com

HIGH VOLTAGE CIRCUIT BREAKER & SUBSTATION | CIRCUIT BREAKER TIMING TEST SETS

C i r c u i t B r e a ke r T i m i n g Te s t S e t s

Doble TDR9100/TDR900

• Includes four breaks per phase, three transducer connections and six event channels

• Operated by T-Doble software provided on a preconfigured laptop or Doble DUC

• Provides main contact timing, travel/motion, resistance and capacitance measurements

• Expandable with two or three systems for multiple contact applications

• Detects main contact and resistor contact timing errors

Doble TDR9100/TDR900Circuit Breaker Test System

Omicron CIBANO 500

• Combines a circuit breaker timer, 100A static DLRO, minimum pick up and undervoltage source, and a coil and motor power supply in one instrument

• Unique cabling connection system dramatically reduces connection time and effort

• Transducer node CB TN3 provides motion/velocity input from most digital or analog transducers

• Contact module CB MC2 Provides convenience – one connection to primary breaker contacts for all tests; only one cable connection to instrument

• Combined with MC2 and CB TN3, fully analyzes performance by measuring

• Main contact and resistor contact timing, stroke, velocity, over-travel, bounce back and contact wipes

• Operated by primary test manager software which produces a comprehensive report with all tests

Omicron CIBANO 5003-in-1 Circuit Breaker Test System

Omicron CB TN3

Vanguard CT-6500

• Fully analyzes performance by measuring main contact and resistor contact timing, stroke, velocity, over-travel, bounce back and contact wipes

• Contact and motion/travel analyzed on all breaker operations: open, close, open-close and close-open

• Operates with insertion resistors up to 7,000Ω

• Trip/close coil current monitoring capabilities

• Monitors all three-breaker poles simultaneously

Vanguard CT-6500Circuit Breaker Timer Analyzer

37(866) 352-5550 | protecequip.com

Vanguard CT-7000 S3/S6

• Fully analyzes performance by measuring main contact and resistor contact timing, stroke, velocity, over-travel, bounce back and contact wipes

• Contact and motion/travel analyzed on all breaker operations: open, close, open-close and close-open

• Initiates all breaker operations

• Monitors all three-breaker poles simultaneously

• Available with three or six timing channels

Vanguard CT-7000 S3/S6Circuit Breaker Timer and Travel Analyzer

Vanguard CT-8000 S3

• Fully analyzes performance by measuring main contact and resistor contact timing, stroke, velocity, over-travel, bounce back and contact wipes

• Integrated “on-line timing” or first trip analysis

• Initiates all breaker operations

• Trip/close coil current monitoring capabilities

• Monitors all three breaker poles simultaneously

Vanguard CT-8000 S3Circuit Breaker Timer Analyzer

C i r c u i t B r e a ke r T i m i n g Te s t S e t s

HIGH VOLTAGE CIRCUIT BREAKER & SUBSTATION | CIRCUIT BREAKER TIMING TEST SETS

38 (866) 352-5550 | protecequip.com

HIGH VOLTAGE CIRCUIT BREAKER & SUBSTATION | DIGITAL LOW RESISTANCE OHMMETERS

Megger DLRO10HD

• Internal storage of test data for download or printing on site with optional printer

• Lightweight compact design Included heavy-duty alligator clamp or optional C-clamps (33 lbs)

• Operational ingress protection is IP54 (battery power only) ensuring protection from the elements

• Rotary mode switch with bidirectional (current reversal with averaging cancels thermal EMFs), unidirectional, automatic, continuous and inductive modes

Megger DLRO10HD10A Digital Low Resistance Ohmmeter (DLRO)

AEMC 6240/6250

• Battery operated, light weight and compact design

• User selectable test current and resistance ranges

• 6250 model adds internal storage of readings with data storage and analysis software included

• Includes temperature compensation and user selectable resistive or inductive materials measurement

AEMC 6240/625010A Micro-Ohmmeter

D i g i t a l Lo w R e s i s t a n c e O h m m e t e r s

• New Difference Meter for quick data comparisons

• Uses long leads at 1A without compromising test speed

• Safely test the resistance of inductive loads at 1A

• >600V active protection against inadvertent live connections without blowing a fuse

Megger DLRO2 - 2A Hand-Held Low Resistance Ohmmeter

Megger DLRO2

Megger MOM2

• Lightweight and compact design

• Stores test records in on-board memory or to USB flash drive

• 1A to 200A test current

• Heavy-duty and field rugged

Megger MOM2200A Digital Low Resistance Ohmmeter (DLRO)

Megger DLRO600

• Test currents from 10A to 600A

• Internal storage of test data for download or printing on site with optional printer

• Lightweight compact design (33 lbs)

• Includes heavy-duty alligator clamp or optional C-clamps

Megger DLRO600600A Digital Low Resistance Ohmmeter (DLRO)

Megger DLRO200-115

• Lightweight and compact design

• Stores test records in on-board memory or to USB flash drive

• 1A to 200A test current

• Heavy duty and field rugged

Megger DLRO200-115200A Digital Low Resistance Ohmmeter (DLRO)

39(866) 352-5550 | protecequip.com

HIGH VOLTAGE CIRCUIT BREAKER & SUBSTATION | DIGITAL LOW RESISTANCE OHMMETERS

D i g i t a l Lo w R e s i s t a n c e O h m m e t e r s

40 (866) 352-5550 | protecequip.com

HIGH VOLTAGE CIRCUIT BREAKER & SUBSTATION | DIGITAL LOW RESISTANCE OHMMETERS

D i g i t a l Lo w R e s i s t a n c e O h m m e t e r s

Raytech Micro Centurion II MC-2

• Selectable output from 10A to 200A

• High precision – measurements from 0.01μΩ to 20μΩ with resolution of 0.01μΩ

• Internal memory records 2,000 test results

• Heavy-duty and field rugged

Raytech Micro Centurion II MC-2200A Micro Ohm Meter

Raytech Micro Junior 2

• Automated measurement detection and storage modes

• On-board printer

• Automatic polarity reversal

• Battery operated

Raytech Micro Junior 210A Micro Ohm Meter

Vanguard Auto-Ohm 100

• Selectable output from 10A to 100A

• Programmable current rise and fall rates

• Auto-test mode permits applying sense leads across points of interest

Vanguard Auto-Ohm 100100A Micro-Ohmmeter

41(866) 352-5550 | protecequip.com

HIGH VOLTAGE CIRCUIT BREAKER & SUBSTATION | DIGITAL LOW RESISTANCE OHMMETERS

D i g i t a l Lo w R e s i s t a n c e O h m m e t e r s

• Lightweight and compact design (17 lbs)

• On-board QWERTY Keyboard

• Stores test records in on-board memory or to USB flash drive

• 1A to 200A test current

• Programmable current rise and fall rates

• Auto-test mode permits applying sense leads across points of interest

Vanguard Auto-Ohm 200 S3200A Micro-Ohmmeter

Vanguard Auto-Ohm 200 S3

42 (866) 352-5550 | protecequip.com

HIGH VOLTAGE CIRCUIT BREAKER & SUBSTATION | HIPOTENTIAL TEST SETS

High Voltage ALT-120/60

• Side tap at 60kV provides 115mA capacity

• Top tap at 120kV provides 58mA capacity

• 120V / 25A input

• Ideal for ISO phase bus testing, aerial lift devices and elevated platforms, most common dielectric withstand tests, and as a source voltage for apparatus PD testing

• Not suitable for cable testing

High Voltage ALT-120/6060kV and 120kV Power Frequency AC Hipot

High Voltage PFT-301CM

• Convenient one-piece field portable design

• Primary connected single range voltmeter: 0 to 30 kV AC

• Single range current meter: 0 to 40 mA AC

• Transit protected meters prevent meter damage between test sites

• 20 ft shielded output and return cables

High Voltage PFT-301CM30kV Power Frequency AC Hipot

High Voltage PFT-303

• Convenient one-piece field portable design

• Secondary connected 2 range voltmeter: 0 to 15 / 30kV AC

• 3 range current meter: 0 to 1mA AC with x1, x10, and x100 multipliers

• 20 ft shielded output and return cables

• Gapped core transformer design for capacitive load compensation

High Voltage PFT-30330kV Power Frequency AC Hipot

H i p o t e n t i a l Te s t S e t s

43(866) 352-5550 | protecequip.com

HIGH VOLTAGE CIRCUIT BREAKER & SUBSTATION | HIPOTENTIAL TEST SETS

H i p o t e n t i a l Te s t S e t s

High Voltage PTS-75/PTS-80

• Performs repeatable, accurate measurement of breakdown voltage of insulating oils

• Three rates of rise: 500V / 2,000V / 3,000V per second

• Arc detection with automatic shutdown and measurement hold

• DTS-60A adds full programming and automation with on-board printer, internal results storage and RS-232 interface, user defined test sequences and temperature sensor

High Voltage PTS-75/PTS-8075kV and 80kV DC High Voltage Test Set and Megohmmeter

High Voltage PFT-503CM

• Convenient one-piece field portable design

• Secondary connected 2 range voltmeter: 0 to 15 / 30kV AC

• 3 range current meter: 0 to 1mA AC with x1, x10, and x100 multipliers

• Guard/ground circuit for accurate leakage current measurement

• Gapped core transformer design for capacitive load compensation

High Voltage PFT-503CM50kV Power Frequency AC Hipot

High Voltage PFT-652CM

• Convenient two-piece field portable design

• Secondary connected 2 range voltmeter: 0 to 32.5 / 65kV AC

• 3 range current meter: 0 to 1mA AC with x1, x10, and x100 multipliers

• Transit protected meters prevent meter damage between test sites

• Guard/ground circuit for accurate leakage current measurement

High Voltage PFT-652CM65kV Power Frequency AC Hipot

44 (866) 352-5550 | protecequip.com

HIGH VOLTAGE CIRCUIT BREAKER & SUBSTATION | HIPOTENTIAL TEST SETS

H i p o t e n t i a l Te s t S e t s

High Voltage VLF-4022CM

• Output voltage is 40kV peak at 5.5mA max

• Adjustable output frequency of 0.1Hz, 0.05Hz, or 0.02Hz (Sinusoidal)

• Capable of testing 35kV cable up to a maximum distance of 10 miles

• Metering includes voltmeter ±0 to 60k VAC peak, charging current meter

• 0 to 100mA peak, and load capacitance meter 0 to 6μF

• Two piece design; controller is approximately 75 lbs and the high voltage tank is approximately 120 lbs

High Voltage VLF-4022CM40kV High Load Capacity Portable VLF Hipot

High Voltage PTS-200

• 200kV output voltage at 5mA

• Continuously adjustable output voltage

• High voltage tank is approximately 150 lbs, controller is approximately 35 lbs

• Dual range voltage meter scaled 0 to 80/200kV

• Microamp and megohm meter scales for both leakage current and resistance measurements

High Voltage PTS-200200kV DC Hipot and Megohmmeter

High Voltage PTS-130

• 130kV output voltage at 10mA

• Continuously adjustable output voltage

• Functional two piece design

• High voltage tank is approximately 82 lbs, controller is approximately 35 lbs

• Dual range voltage meter scaled 0 to 70/130kV

High Voltage PTS-130130kV DC Hipot and Megohmmeter

45(866) 352-5550 | protecequip.com

HIGH VOLTAGE CIRCUIT BREAKER & SUBSTATION | HIPOTENTIAL TEST SETS

H i p o t e n t i a l Te s t S e t s

High VoltageVLF-34E/VLF-65E

• 34kV / 65kV output voltage

• Adjustable output frequency

• 5μF load @ 0.02Hz

• 120V input voltage

High Voltage VLF-34E/VLF-65E34kV/65kV VLF Hipot

HV Diagnostics PDTD60/PDTD120

• 60kV / 120kV VLF output voltage

• 120V input voltage

• 2 piece unit

• Suitable for 69kV cable (PDTD60) and 35kV cable (PDTD120)

• Total weight 347 lbs (PDTD60) and 90 lbs (PDTD120)

HV Diagnostics PDTD60/PDTD12060kV and 120kV Partial Discharge and Tan Delta System

Phenix 6CP100/50-10

• Ideal high voltage source for PD measurements using the ICM Flex for off-line partial discharge apparatus testing; not suitable for cable testing

• Minimal partial discharge – less than 4pC at 100kV and less than 3pC at 80kV

• Two-piece design with hand truck mount for controller and tank improves portability

• Side tap at 50kV provides 200mA capacity; top tap at 100kV provides 100mA capacity

• 230V input, and adjustable overload circuit

Phenix 6CP100/50-1050kV & 100kV AC Dielectric Test Set

46 (866) 352-5550 | protecequip.com

HIGH VOLTAGE CIRCUIT BREAKER & SUBSTATION | HIPOTENTIAL TEST SETS

H i p o t e n t i a l Te s t S e t s

• Compact, single-piece construction for improved portability and logistics compared to AC or DC hipots with similar cable testing capability

• Simple and intuitive menu driven user interface

• Consistent controls, menus and connections on each model ensures minimal learning curve from instrument to instrument

• Appropriate for testing cables, capacitors, switchgear, transformers, rotating equipment, insulators and bushings

• Meets requirements of a Type-I withstand testing according to IEEE 400.2 and other national and international standards

• User specified or automatically adjusted output frequency according to measured capacitance (0.1Hz to 0.01Hz in 0.01Hz steps)

• Sinusoidal, cosine rectangular, or DC output waveform

• True symmetrical sinusoidal, load independent output waveforms across full load range

• Short circuit protection with active arc management

• Digital metering displays voltage (RMS or Peak), capacitance, resistance, elapsed time, and flashover voltage

• Storage of test results and test sequences (test plans) in internal memory and on-board USB port for USB flash drive

• HVA Control Center software produces professional reports

• Keyed safety interlock and emergency shutdown

• Seamless integration with HV Diagnostics tan delta measurement systems, HV Diagnostics partial discharge analysis equipment and Power Diagnostix ICMFlex

• HVA28TD model adds on-board tan delta measurement system

HVA Model Peak Voltage RMS Voltage Acceptance Maintenance

HVA28TD 28kV 20kV Up to 15kV Up to 20kV

HVA30 30kV 22kV Up to 16kV Up to 22kV

HVA34 34kV 24kV Up to 15kV Up to 25kV

HVA34TD 34kV 24kV Up to 15kV Up to 25kV

HVA45TD 45kV 32kV Up to 25kV Up to 30kV

HVA60 60kV 44kV Up to 35kV Up to 46kV

HVA90 90kV 64kV Up to 46kV Up to 69kV

HVA120 120kV 85kV Up to 69kV Up to 69kV

HV Diagnostics HVA High Voltage Test Sets28kV, 30kV, 34kV, 45kV, 60kV, 90kV and 120kV Hipots for VLF Withstand Testing, Tan Delta (Dissipation Factor) and Off-Line Partial Discharge Cable Testing

HV Diagnostics HVA28TD

HV Diagnostics HVA34

HV Diagnostics HVA120

47(866) 352-5550 | protecequip.com

HIGH VOLTAGE CIRCUIT BREAKER & SUBSTATION | POWER FACTOR TEST SETS

Po w e r F a c t o r Te s t S e t s

• Rugged construction for field use with laboratory accuracy and precision

• Industry standard for testing electrical apparatus such as transformers, generators and cables

• Evaluates integrity of high voltage substation apparatus by measuring power factor/tan delta

• Measures capacitance to evaluate physical changes

• Measures accurately in high electrostatic and electromagnetic conditions

• Measures excitation current to evaluate transformer magnetizing circuit

• Line frequency modulation technology eliminates substation interference

• Automated testing procedures through DTA or manual through M4000 clipboard

• Available with an M4000 and DTA preconfigured laptop computer or DUC, and all application appropriate accessories

• Internal field calibration reference ensures accurate testing

• Built in diagnostics provide information on instrument status

• Output current to 300mA at 10kV (total output power 3kVA) for better replication of in-service conditions

• Optional Type C resonator increases output capacity

• Optional M4110 available for measuring the impedance of the apparatus under test

• Optional M4140 available for measuring capacitance of capacitor banks

• Optional liquid insulation test cell for measuring insulating characteristics of oil

• Optional TTR capacitor for measuring transformer ratio

Doble M4000/M4100Power Factor Test Set

Doble Type-C

• Used in conjunction with the Doble M4000/M4100 to provide extra current needed for high voltage test levels

• Iron core reactor with adjustable air gap

• Capable of resonating capacitance of 0.05 to 1.0μF at 10kV 60Hz

Doble Type-CResonating Inductor

Doble M4000/M4100

Doble M4110

Doble M4140

48 (866) 352-5550 | protecequip.com

HIGH VOLTAGE CIRCUIT BREAKER & SUBSTATION | POWER FACTOR TEST SETS

Po w e r F a c t o r Te s t S e t s

Megger DELTA4310

• Fully automatic insulation power factor/dissipation factor test set up to 12kV

• Suitable for testing transformers, bushings, circuit breakers, cables, lightning arresters and rotating machinery

• Measures excitation current of transformer windings, automatic tip-up tests and HV turns-ratio testing (with optional TTR capacitor)

Megger DELTA4310Power Factor Test Set

Megger CB100

• Lightweight and portable (21 lbs)

• Output of 26V at 100Hz minimizes 60Hz interference

• Performs UST and GST configuration testing

• Direct reading of capacitance and dissipation factor

• Simple manual interface

• Optimal for transformer dry out

Megger CB100Power Factor Test Set

Megger MIT525

• Simple to use with intuitive controls and features

• Battery operated

• Performs PI, step voltage, dielectric discharge, dielectric absorption ratio automatically

• Burn and breakdown functions available in insulation resistance mode

Megger MIT525Insulation Resistance Meter

49(866) 352-5550 | protecequip.com

HIGH VOLTAGE CIRCUIT BREAKER & SUBSTATION | POWER FACTOR TEST SETS

• Used with Omicron CPC-100 and TD-1

• Provides connections for three-phase winding resistance and three-phase TTR measurements

• Primary Test Manager (PTM) software provides automated (sequential) testing of all phases and each tap changer position

• Permits one-time cable connections reducing time spent connecting cables

• Minimizes erroneous results with automated testing

Omicron CP SB1Switch Box for Automated Transformer Testing

Omicron CP SB1

Po w e r F a c t o r Te s t S e t s

• A complete transformer test system, including 12kV power factor tests

• Measures capacitance, dissipation factor tan δ (tan delta), power factor COS φ, watts losses, power (effective power, apparent power and reactive power), and impedance (absolute value, phase, inductance, resistance, quality) with optional CP TD1 component

• On-board computer driven test plans to replicate or trend power factor tests with existing values

• Applies up to 12kV at variable frequencies which enhances diagnosis of insulation aging

• Automatic power factor testing via Omicron’s primary test manager software with the included preconfigured laptop computer or via front panel controls (includes test templates)

• Provides for automated testing of power transformers, CTs, VTs, resistance testing and more

• Optimal for emergent requirements or remote applications; one device replaces multiple instruments

• Stand alone functionality for:

y Ratio, burden and polarity, phase and magnitude error, excitation curve, winding resistance, secondary burden and dielectric withstand tests for CTs and PTs

y Ratio, winding resistance, tap changer testing, excitation current, short circuit impedance measurement and leakage reactance testing of transformers

y Contact resistance, winding resistance, ground resistance or measurement of complex impedances

y Single-phase testing of primary and secondary relays (including overcurrent, over voltage, undervoltage and frequency relays

• 2kV AC voltage source current source to 400A DC and 800A AC

• Optional CP CB2 boosts current output to 2,000A AC

• Optional CP TD12 for performing power/dissipation (tan delta) factor and capacitance measurements

• More CPC-100 accessories available on pages 32, 33 and 111

Omicron CPC 100Multifunctional Primary Test System

Omicron CP B2

Omicron CP TD1

Omicron CPC 100

Omicron CP TD12

50 (866) 352-5550 | protecequip.com

HIGH VOLTAGE CIRCUIT BREAKER & SUBSTATION | RECLOSER CONTROL TEST SETS

R e c l o s e r C o n t r o l Te s t S e t s

Cooper Power Systems Eaton VFI

• Designed to be used with Cooper Power Systems Eaton pad-mounted VFI switchgear

• Simulates fault current for verification of minimum trip values and time current characteristics of tri-phase and TPG electronic control boards

• On-board flux-shift trippers enable self-checking of the VFI tester

• Performs minimum-trip tests, time current curve characteristic tests, control operation test, instantaneous trip test, battery and flux-shift tests

• Limited testing of SCADA accessory board functions including verification of the minimum trip multiplier function and inrush restraint feature

Cooper Power Systems Eaton VFIVFI Tester

Omicron ARCO 400

• Enables three-phase testing of all types of recloser controls

• LEDs indicating breaker positions for each phase

• Safe and touch-proof combined test interface

• Accurate three-phase, 12.5A current amplifiers enable both testing at very low amplitudes and the testing of functions with high fault values

• Operated by the ARCO control software

Omicron ARCO 400Universal Test Set for Recloser Controls

Cooper Power Systems Eaton KMET1

• Ideal for testing ME Form 2, Form 3, Form 3A, Form 4A, Form 4C, Form 4D, Form 5, Form 6, Type FX, Type FXA, and FXB Controls

• Verifies operation of the electronic recloser control

• Verifies electrical operation of the recloser

• Note: power must be available for the recloser for electrical operation

• Recloser simulator circuit indicates operation with LEDs and simulates response time of the recloser mechanism to trip and close signals

Cooper Power Systems Eaton KMET1MET Recloser Controller Tester

KMET45811 DC Nova

Cooper Power KMET45811 & DC Nova 14 to 19 pin accesso-ries available for use with the

KMET1

51(866) 352-5550 | protecequip.com

HIGH VOLTAGE CIRCUIT BREAKER & SUBSTATION | TRANSDUCER TEST SETS

Manufacturer Model Description

Doble 9084UCCan be used to interface any Doble travel transducer to a Van-guard circuit breaker analyzer

Doble TR3171 Specifically designed for ABB AHMA 4/8 Mechanisms

Doble TR318640 ft rotary transducer that provides direct capture of the breaker’s true linear motion

Doble TR318940 ft linear transducer installs in minutes, with no adapters or modifications. Provides direct capture of the breaker’s true linear motion

Doble TR3190Linear and rotary transducer is for use in conjunction with the Doble TR3100, TDR9000, and TDR900 series units

Doble TRMLP50 Resistor type rotary

Fuji FLD22A small diameter sensor (2MHz) with a pipe diameter range of 0.50" to 4.0" and a temperature range of -40 to 212°F

Omicron CB TN3Transducer node for CIBANO500 checks the entire switch mechanism and the mechanical links during the opening and closing process

Vanguard RT-125" rotary transducer with magnetic mount is used formeasuring circuit-breaker contact stroke, velocity, over-travel, and bounce back

Vanguard RT-2

10" rotary transducer is used for measuring circuit-breaker contact stroke, velocity, over-travel and bounce back. With the use of a Vanguard digital circuit breaker analyzer, neither cali-bration nor setting is required

Vanguard TR-125" linear transducer used for measuring circuit-breaker contact stroke, velocity, over-travel and bounce back. Neither calibration nor setting is required

Vanguard TR-210" linear transducer used for measuring circuit-breaker contact stroke, velocity, over-travel and bounce back. Neither calibration nor setting is required

Vanguard TR1 ext 25 ft transducer extension cable

Vanguard TR-HMBRotary transducer used for measuring circuit-breaker contact stroke, velocity, over-travel and bounce back. Neithercalibration nor setting is required

Tra n s d u c e r Te s t S e t s

52 (866) 352-5550 | protecequip.com

53(866) 352-5550 | protecequip.com

LO W/ M E D I U M VO LTAG E C I RC U I T

B R E A K E R S & S W I TC H G E A RCircuit breakers have historically functioned as the protective muscle of the electrical power system. Their effectiveness in performing their job depends on the unique application, design and operating condition. While protective guardians vary widely regarding design and construction, they continue to share in the basic functionality of conducting or interrupting the flow of electricity. Additionally, their ability to perform these functions in concert with their intended design is subject to mechanical, electrical and environmental impacts. Like an insurance policy that fails to protect, a circuit breaker that does not serve its protective purpose is of little value. When something occurs resulting in unexpected fault conditions, we need to be able to count on circuit breakers to perform as intended. A testing and maintenance program will help to provide confidence that the electrical system is in good health. Protec carries an inventory of test equipment for all your circuit breaker and switchgear testing needs.

D i g i t a l Lo w R e s i s t a n c e O h m m e t e r s

LOW/MEDIUM VOLTAGE CIRCUIT BREAKERS & SWITCHGEAR | DIGITAL LOW RESISTANCE OHMMETERS

AEMC 6240/6250

• Battery operated, light weight and compact design

• User selectable test current and resistance ranges

• 6250 model adds internal storage of readings with data storage and analysis software included

• Includes temperature compensation and user selectable resistive or inductive materials measurement

AEMC 6240/625010A Micro-Ohmmeter

• New Difference Meter for quick data comparisons

• Uses long leads at 1A without compromising test speed

• Safely test the resistance of inductive loads at 1A

• >600V active protection against inadvertent live connections without blowing a fuse

Megger DLRO2 - 2A Hand-Held Low Resistance Ohmmeter

Megger DLRO2

54 (866) 352-5550 | protecequip.com

D i g i t a l Lo w R e s i s t a n c e O h m m e t e r s

LOW/MEDIUM VOLTAGE CIRCUIT BREAKERS & SWITCHGEAR | DIGITAL LOW RESISTANCE OHMMETERS

Megger DLRO200-115

• Lightweight and compact design

• Stores test records in on-board memory or to USB flash drive

• 1A to 200A test current

• Heavy duty and field rugged

Megger DLRO200-115200A Digital Low Resistance Ohmmeter (DLRO)

Megger DLRO600

• Test currents from 10A to 600A

• Internal storage of test data for download or printing on site with optional printer

• Lightweight compact design (33 lbs)

• Includes heavy-duty alligator clamp or optional C-clamps

Megger DLRO600600A Digital Low Resistance Ohmmeter (DLRO)

Megger DLRO10HD

• Internal storage of test data for download or printing on site with optional printer

• Lightweight compact design (33 lbs)

• Includes heavy-duty alligator clamp or optional C-clamps

Megger DLRO10HD10A Digital Low Resistance Ohmmeter (DLRO)

55(866) 352-5550 | protecequip.com

Raytech Micro Junior 2

• Automated measurement detection and storage modes

• On-board printer

• Automatic polarity reversal

• Battery operated

Raytech Micro Junior 210A Micro Ohm Meter

LOW/MEDIUM VOLTAGE CIRCUIT BREAKERS & SWITCHGEAR | DIGITAL LOW RESISTANCE OHMMETERS

D i g i t a l Lo w R e s i s t a n c e O h m m e t e r s

Megger MOM2

• Lightweight and compact design

• Stores test records in on-board memory or to USB flash drive

• 1A to 200A test current

• Heavy-duty and field rugged

Megger MOM2200A Digital Low Resistance Ohmmeter (DLRO)

Raytech Micro Centurion II MC-2

• Selectable output from 10A to 200A

• High precision – measurements from 0.01μΩ to 20μΩ with resolution of 0.01μΩ

• Internal memory records 2,000 test results

• Heavy-duty and field rugged

Raytech Micro Centurion II MC-2200A Micro Ohm Meter

• Lightweight and compact design (17 lbs)

• On-board QWERTY Keyboard

• Stores test records in on-board memory or to USB flash drive

• 1A to 200A test current

• Programmable current rise and fall rates

• Auto-test mode permits applying sense leads across points of interest

Vanguard Auto-Ohm 200 S3200A Micro-Ohmmeter

Vanguard Auto-Ohm 200 S3

56 (866) 352-5550 | protecequip.com

D i g i t a l Lo w R e s i s t a n c e O h m m e t e r s

LOW/MEDIUM VOLTAGE CIRCUIT BREAKERS & SWITCHGEAR | DIGITAL LOW RESISTANCE OHMMETERS

• Selectable output from 10A to 100A

• Programmable current rise and fall rates

• Auto-test mode permits applying sense leads across points of interest

Vanguard Auto-Ohm 100100A Micro-Ohmmeter

Vanguard Auto-Ohm 100

57(866) 352-5550 | protecequip.com

LOW/MEDIUM VOLTAGE CIRCUIT BREAKERS & SWITCHGEAR | HIGH CURRENT TEST SETS

H i g h C u r r e n t Te s t S e t s

ETI PI-1600B

• Convenient one-man portable three piece design, total weight approximately 270 lbs

• Intuitive and rugged MAC-20 digital controller with memory ammeter and seconds/cycles timer

• 240V input with optional autotransformer for 480V input

• Will test low-voltage, molded-case and metal-clad, direct acting AC circuit breakers from various manufacturers

• Can also be used on high current applications like ratio transformers, and heat runs

• Consists of PI-800 test set plus PI-AUX output unit to double output capacity

• Output current and overload capabilities in the chart below

Electrical Test Instruments ETI PI-1600B16,000A High Current Test Set

4.2V Series/Parallel 8.4V Series Overload Duty On Time Off Time Max Input @ 240V

1,600A 800A 1X 100% Continuous N/A 38A

2,250A 1,125A 1.4X 50% 15 Min 15 Min 53A

3,200A 1,600A 2X 25% 5 Min 15 Min 75A

4,800A 2,400A 3X 10% 2.5 Min 20 Min 112A

6,400A 3,200A 4X 6% 75 Sec 20 Min 150A

8,000A 4,000A 5X 4% 4 Sec 2 Min 187A

11,200A 5,600A 7X 2% 2 Sec 2 Min 262A

16,000A 8,000A 10X 1% 0.6 Sec 1 Min 375A

ETI PI-1600B Duty Cycles

58 (866) 352-5550 | protecequip.com

ETI PI-5000/PI-6000

• Intuitive and reliable MAC-20 and MAC-21 digital instrumentation

• Package and memory ammeter

• Seconds/cycles timer

• 240V or 480V Input (switch selectable)

• 240V limits output to 30kA for PI-6000

• Included 1/2" and 3/4" stabs, 150 ft input power cables and output cables to meet the user’s specific requirement

Electrical Test Instruments ETI PI-5000/PI-600040,000A/60,000A High Current Test Set

9V Parallel 18V Series Overload Duty On Time Off Time

4,000A 2,000A 1X 100% Continuous N/A

5,600A 2,800A 1.4X 50% 15 Min 15 Min

8,000A 4,000A 2X 25% 5 Min 15 Min

12,000A 6,000A 3X 10% 1.5 Min 15 Min

16,000A 8,000A 4X 6% 45 Sec 15 Min

20,000A 10,000A 5X 4% 4 Sec 2 Min

28,000A 14,000A 7X 2% 2 Sec 2 Min

40,000A 20,000A 10X 1% 1 Sec 2 Min

9V Parallel 18V Series Overload Duty On Time Off Time

6,000A 3,000A 1X 100% Continuous N/A

8,400A 4,200A 1.4X 50% 15 Min 15 Min

12,000A 6,000A 2X 25% 5 Min 15 Min

18,000A 9,000A 3X 10% 1.5 Min 15 Min

24,000A 12,000A 4X 6% 45 Sec 15 Min

30,000A 15,000A 5X 4% 4 Sec 2 Min

42,000A 21,000A 7X 2% 2 Sec 2 Min

60,000A 30,000A 10X 1% 1 Sec 2 Min

ETI PI-6000 Duty Cycles

ETI PI-5000 Duty Cycles

H i g h C u r r e n t Te s t S e t s

LOW/MEDIUM VOLTAGE CIRCUIT BREAKERS & SWITCHGEAR | HIGH CURRENT TEST SETS

59(866) 352-5550 | protecequip.com

High Voltage PFT-303/PFT-503CM

• 0 to 100mA output current; total output 3kVA (capacitive loads)

• 20 ft shielded output cable with alligator clip

• Approximately 75 lbs

• Ideal for testing low capacitance substation apparatus: vacuum bottles, breakers, switchgear, bushing, reclosers, small transformers and small motors

• Not suitable for ISO phase bus applications or cable testing

High Voltage PFT-303/PFT-503CM30kV and 50kV AC Hipot

High Voltage PFT-652CM

• Two-piece design improves portability and reduces transportation cost

• 2kVA (capacitive) total output

• Analog metering for current leakage and voltage output

• 20 ft shielded output cable with alligator clamp

• Ideal for low capacitance substation apparatus

• Not suitable for ISO phase bus or cable applications

High Voltage PFT-652CM65kV Power Frequency AC Hipot

LOW/MEDIUM VOLTAGE CIRCUIT BREAKERS & SWITCHGEAR | HIGH CURRENT TEST SETS

H i g h C u r r e n t Te s t S e t s

Megger 230425

• One second or continuous testing

• Adjustable leakage current limit from 0.3mA to 12mA

• High voltage cut-off within 50mS of arcing or exceeding preset current leakage level

• Automatic cut-off if ground circuit resistance exceeds 15Ω during a test

• Familiar and simple controls in a lightweight package

Megger 2304254kV AC and 5kV DC Hipot

60 (866) 352-5550 | protecequip.com

H i g h C u r r e n t Te s t S e t s

LOW/MEDIUM VOLTAGE CIRCUIT BREAKERS & SWITCHGEAR | HIGH CURRENT TEST SETS

Megger CB-832

• Instantaneous current to 2,000A or continuous current to 500A

• Memory ammeter and seconds/cycles timer

• Simple manual controls with robust construction

Megger CB-8321,800A High Current Test Set

Output On Time Off Time

500A 30 Min 30 Min

1,000A 3 Min 8 Min

1,500A 30 Sec 4 Min

2,000A 7 Sec 2 Min

Megger CB-845

• Instantaneous current to 4,500A or continuous current to 1,200A

• Memory ammeter and seconds/cycles timer

• Two-man portable; controller weighs 70 lbs, output transformer weighs 123 lbs

• Input voltage 208V and 240V, 30A

Megger CB-8454,500A High Current Test Set

Megger DDA-1600

• Ideal for testing circuit breakers up to 1,600A

• Modular and portable design – heaviest component is 210 lbs

• Convenient 480V / 150A input service

• Series/parallel selection adjusts for a higher output voltage and reduced current

• Maximum continuous current of 1,600A; instantaneous current of 19,200A through an air frame circuit breaker or 14,400A through a molded case circuit breaker

Megger DDA-160016,000A Circuit Breaker Test Set

61(866) 352-5550 | protecequip.com

LOW/MEDIUM VOLTAGE CIRCUIT BREAKERS & SWITCHGEAR | HIGH CURRENT TEST SETS

H i g h C u r r e n t Te s t S e t s

Megger DDA-6000

• Digital controller includes memory ammeter, timer, and voltmeter

• Intuitive DDA-1 controller provides for simple operation

• Maximum current at 480V input:

y 6,250A maximum continuous current

y 60,000A maximum current through a circuit breaker

y 100,000A maximum current through a short circuit

• 30 minutes on / 30 minutes off duty cycle

• Autotransformer for 208V / 240V source

Megger DDA-600060,000A Universal Circuit Breaker Test Set

Current On Time Off Time

4,500A Continuous N/A

6,250A 30 Min 30 Min

10,000A 15 Min 45 Min

30,000A 2 Min 60 Min

60,000A 5 Sec 12 Min

Megger MS-2A

• Instantaneous current to 500A or continuous current to 240A

• Memory ammeter and seconds/cycles timer

• Lightweight and compact (33 lbs)

• Simple operations and controls

Megger MS-2A500A Circuit Breaker and Overcurrent Relay Test Set

Megger ODEN AT

• Compact hand truck/cart provides enhanced mobility in tight spaces where traditional large frame systems are impractical

• Quick disassembly/re-assembly of modular components enables access to roofs and mezzanines so circuit breakers can be left in place

• Unique I/30 function allows current to be preset using lower currents to prevent apparatus from overheating and influencing results or slowing testing progress

• 480V input voltage, 3,800A @ 3.6V and 1,250A @ 10.7V continuous

• 21,900A @ 3.6V and 7,200A @ 10.7V instantaneous

Megger ODEN AT21,900A Primary Current Injection Test System

62 (866) 352-5550 | protecequip.com

LOW/MEDIUM VOLTAGE CIRCUIT BREAKERS & SWITCHGEAR | HIGH CURRENT TEST SETS

H i g h C u r r e n t Te s t S e t s

Vanguard MCCB-250

• Programmable high current source appropriate for testing molded-case circuit breakers

• Circuit breakers and thermal magnetic or solid state overload motor protection relays

• Rugged and robust design for field applications

• On-board multifunction timer

• Simple operations and controls

• Four current outputs (5A @ 120V, 25A @ 24V, 120A @ 6V and 250A @ 3V)

Vanguard MCCB-250500A Circuit Breaker Test Set

Current On Time Off Time

250A 30 Min 30 Min

500A 3 Min 5 Min

750A 30 Sec 4 Min

1,000A 4 Sec 7 Min

SMC Raptor C-05

• Suitable for numerous test and measurement functions involving medium to moderate current where the distance to the tested device is not a factor, as when testing MCBs or medium-sized MCCBs

• Can comfortably work in the range of 500A using a narrow connection (around 25sq. mm)

• Output frequency can be varied between 20Hz and 400Hz

• Auxiliary output, binary input and measurement functions are automatically configured by the standard set of test templates

SMC Raptor C-053,800A Multifunctional Primary Testing System

63(866) 352-5550 | protecequip.com

Manufacturer Model Voltage Rating

AEMC 6536 1kV

Fluke 1587 FC 1kV

Fluke 1587MDTFC 1kV

Megger 210415 15kV

Megger BM15R 5kV

Megger MIT485 1kV

Megger MIT520 5kV

Megger MIT525 5kV

Megger MIT1025 10kV

Megger MIT1525 15kV

Megger S1554 5kV

Metrel 3103 1kV

Metrel 3200 10kV

Megger MIT insulationresistance units feature PI,

DAR, DD, SV & Ramp testing

Megger MIT1525

Metrel 3200

Fluke 1587 FC

I n s u l a t i o n R e s i s t a n c e Te s t S e t s

LOW/MEDIUM VOLTAGE CIRCUIT BREAKERS & SWITCHGEAR | INSULATION RESISTANCE TEST SETS

AEMC 6536

64 (866) 352-5550 | protecequip.com

Model PiecesLargest Breaker

Input VoltageSingle-phase

Max. Output Through a

Breaker

Shipping Weight (with crate)

Megger MS-2A 1 125A 120Vac 750A 45 Lbs.

Vanguard MCCB-250 1 125A 120Vac 1,000A 60 Lbs.

Megger SPI225 1 225A 120Vac 2,000A 62 Lbs

Megger CB-832 1 225A 120Vac 1,800A 104 Lbs.

SMC Raptor C-05 1 350A 240Vac 3,800A 106 Lbs.

Megger CB-845 2 500A 208 / 240Vac 5,000A 280 Lbs.

ETI PI-800 2 800A 120 / 240Vac 8,000A 275 Lbs.

ETI PI-1600B 3 1,600A 240Vac 16,000A 385 Lbs.

Megger DDA-1600 4 1,600A 240Vac 16,000A 400 Lbs.

Megger ODEN AT 1 2,200A 480Vac 21,900A 880 Lbs.

ETI PI-5000 2 4,000A 480Vac 40,000A 1,000 Lbs.

ETI PI-6000 1 6,000A 208 / 240Vac 60,000A 1,650 Lbs.

Megger DDA-6000 1 6,000A208 / 240 /

480Vac60,000A 1,750 Lbs.

LOW/MEDIUM VOLTAGE CIRCUIT BREAKERS & SWITCHGEAR | PRIMARY CURRENT INJECTION TEST SETS

P r i m a r y C u r r e n t I n j e c t i o n Te s t S e t s

Manufacturer Model Trip Unit / Circuit Breaker Reference

ABB 504 Power Shield for I-T-E breakers K-600 through K-4000

ABB 505 LK-800, 1600, 2500, 3200, 4000, 4200

ABB 606 LK-800, 1600, 2500, 3200, 4000, 4200

ABB 607 MPS-C-3, MPS-C-3G, MPS-C-4, MPS-C-4G, MPS-C-5, MPS-C-5G

ABB BTSB Micro Power Shield (MPS-C and MPSC-2000)

ABB PR010/TSACE (PR111, PR112, PR113, PR121, PR122, PR123, PR212, PR222, PR223, Top 25, Emax

ABB EkipSACE, ALL, Emax, Emax DC, Emax 2, ISOMAX, New Emax, VF, New Megamax HF1,2,3,4 T7/T8/X1, Tmax, Tmax XT, X1

Allen-Bradley 140G-ELTT 140G/140MG-G, H, I, J, K, L, M and 140G-N, NS R

Carriere STS100 Carriere FB600ER RMS

Eaton Cutler-Hammer 140D481G03Amptector, Digitrip RMS 500, 510, 600, 610, 700, 800, 810, 910, Optim 750, 1050 **SPB with RMS must be primary injection tested

Eaton Cutler-Hammer 1232C50G05 Seltronic, series C, Digitrip RMS 310, SPB Digitrip RMS 210

Eaton Cutler-Hammer 1232C50G10 (STK2)Seltronic, series C, Digitrip RMS 310, Digitrip RMS 310 mining, SPB Digitrip RMS 210

Eaton Cutler-Hammer 1287C56G02 Seltronic test kit

Eaton Cutler-Hammer 70C1056 Magnum breakers with Digitrip trip sets (520 series, 1150 series)

Eaton Cutler-Hammer 70C1056G54 Magnum breakers with Digitrip trip sets (520 series, 1150 series)

Eaton Cutler-Hammer 7801C57(Pass/Fail) OPTIMizer / handheld programmer for Digitrip OPTIM units 550, 750, and 1050 trip units

Eaton Cutler-Hammer 8779C02G03 DS, DSII adapter for 140D481G03

Eaton Cutler-Hammer MTK1000 Magnum breakers trip unit (upgraded) - Digitrip 520 series, 1150 series

Eaton Cutler-Hammer MTK2000 Magnum breakers trip unit (upgraded) - Digitrip 520 series, 1150 series

65(866) 352-5550 | protecequip.com

S e c o n d a r y C u r r e n t I n j e c t i o n Te s t S e t s

LOW/MEDIUM VOLTAGE CIRCUIT BREAKERS & SWITCHGEAR | SECONDARY CURRENT INJECTION TEST SETS

66 (866) 352-5550 | protecequip.com

Manufacturer Model Trip Unit / Circuit Breaker Reference

Eaton Cutler-Hammer PRTAAPM Aux power module for Digitrip OPTIM trip units 550, 750, and 1050 trip units

Federal Pioneer DDT-USRC USR and USRC overcurrent relay

GE DEH-233 Entellisys test set

GE GTUTK20 EntelliGuard TU test set

GE PST1-1 Power Sensor and Power Sensor 1A

GE TAKTS2 ECS, SST and VersaTrip model 2

GE TTS1 VersaTrip pre-model 2, including breaker types TJS, TKS, TPSS and THSS

GE TVRMS2Power+, RMS9, Epic, MVT Plus and MVT PM or Spectra RMSMicroVersaTrip Plus and MicroVersaTrip PM (TT and A, B, or C types)

GE TVTS1MicroVersaTrip programmers, TP4VT, TP9VT, T4VT, T9VT, TAVT, TP4VT20/25/30 and TP9VT20/25/30/40

MadTest DSM4i1DS Magnum 4-in-1 adapter. Substitute for the 8779C02G03, 8779C02G04 and PRTAAPM

Merlin Gerin 55391 or MEME Test Kit (Masterpact STxx8, STRx8, Compact ST2x4, ST205-3x5, STRx5, STCM2, STCM3, Compact NS STR22, STRx3)

Satin American ETC-PTS ETC trip units

Siemens ELTPHB VL ETU breakers

Siemens PTS-3 Limitrip, Static Trip I (dual trip), and Static Trip III

Siemens PTS-4 Limitrip, Static Trip I (dual trip), Static Trip II, and Static Trip III

Siemens PTS-5Limitrip, Static Trip (dual trip), Static Trip III (only RL and MLA type Static III) (not 3VA)

Siemens SBAPM Auxiliary power module for SB breakers

Siemens TD500 Used to test the Siemens 3VA family of circuit breakers with ETU trip units

Siemens TS-31 JD, LD, MD, or PD, SB and STD breakers, Sensitrip III

S e c o n d a r y C u r r e n t I n j e c t i o n Te s t S e t s (C o n t i n u e d )

LOW/MEDIUM VOLTAGE CIRCUIT BREAKERS & SWITCHGEAR | SECONDARY CURRENT INJECTION TEST SETS

67(866) 352-5550 | protecequip.com

Manufacturer Model Trip Unit / Circuit Breaker Reference

Siemens Westrip Adapter RMS-2000, RMS-2007AF, RMS-2012AF

Siemens WLTS WL Sentron breakers, ETM trip units, ETU trip units (ETU7 Only)

Square D S33595Micrologic (MasterPact, PowerPact, Compact NS) series 2.0, 3.0, 5.0, 6.0, 7.0 and ET trip units

Square D CBTM1 SE module for UTS3

Square D CBTM3 ME-NE-PE module for UTS3

Square D CBTM4A (Series A) M-N-P-S module for UTS-3

Square D CBTMB (Series B) module for UTS-3

Square D UTS-3 Micrologic full function Series B

Square D UTA TesterCompact NSX 100-250, NSX 400-630, Micrologic 2.2M, 2.3M, 3.2, 3.3, 5.2, 5.3, 6.2, 6.3 trip units

Utility Relay Company B-290 Zero-Hertz DC trip units

Utility Relay Company B-291MP AC Pro MP trip units

Utility Relay Company B-292 AC Pro and AC Pro II trip units

Westinghouse 12552C48G02 SCB II breaker operation test set

WestinghouseSPBPTK

(1272C61G02)Pow-R Breaker, Pow-R Trip, Pow-R Trip7

S e c o n d a r y C u r r e n t I n j e c t i o n Te s t S e t s (C o n t i n u e d )

LOW/MEDIUM VOLTAGE CIRCUIT BREAKERS & SWITCHGEAR | SECONDARY CURRENT INJECTION TEST SETS

68 (866) 352-5550 | protecequip.com

Vacuum Interrupters MAC TS4

• Quantitative test predicts the useful life of a vacuum bottle rather than go/no-go tests using an AC or DC hipot

• Uses the penning discharge principle to determine pressure inside the vacuum bottle

• Pressure, wear, and operations count can predict remaining service life

• Data analysis and technology based on measurements of more than 3,000 Vacuum Interrupters

• System is compatible with either fixed or flexible magnetic coils

Vacuum Interrupters MAC TS4Vacuum Interrupter Tester

Vacuum InterruptersPowerVac V1

• Enables testing of GE PowerVac breakers without disassembly

• Used in conjunction with the MAC-TS4, the unit slides over the PowerVac pole assembly

• Determines the remaining service life of a PowerVac vacuum bottle

Vacuum Interrupters PowerVac V1Rigid Magnetic Coil for GE PowerVac Circuit Breakers

Vacuum InterruptersCBT-1202

• Self-contained, multi-use test set designed to operate and interact with all types of circuit breakers

• Incorporates a digital timer to capture and store trip, close and bounce times; and 10 test results can be stored in the internal memory

• Field portable

• 120VAC / 125V DC output for charging spring charged circuit breakers while outside their cubicle

• Has unique cable sets which speed and simplify connection to the breaker under test

Vacuum Interrupters CBT-1202Circuit Breaker Timer

LOW/MEDIUM VOLTAGE CIRCUIT BREAKERS & SWITCHGEAR | VACUUM BOTTLE TEST SETS

Va c u u m B o t t l e Te s t S e t s

Vanguard VBT-60

• Automated testing from 10kV to 60kV DC in 5kV steps

• Selectable dwell time from 5 seconds to 2 minutes

• Digital voltage and current display

• Failure indicator LED

• Lightweight (10 lbs)

• Display indicates test voltage and mA leakage during test

• Selectable overcurrent limits of 100mA, 200mA and 300mA

Vanguard VBT-6060kV Vacuum Bottle Tester

69(866) 352-5550 | protecequip.com

• Operates with insertion resistors up to 7,000Ω and initiates breaker operation

• Trip/close coil current monitoring capabilities

• Determines contact time, stroke, velocity over-travel and contact wipe

• Monitors all three breaker poles at once

• On-board printer for immediate results documentation and on-board test plan storage or repetitive tests

• Stand-alone operation or computer interface allows for data collection and operational control

• USB PC interface and USB flash drive interface with on-board data storage for up to 200 test results and up to 100 test plans

• Simplified connections with one main contact assembly

• More Circuit Breaker Timer and Travel Analyzers available on page 35

Vanguard DigiTMRCircuit Breaker Timer and Analyzer

Va c u u m B o t t l e Te s t S e t s

LOW/MEDIUM VOLTAGE CIRCUIT BREAKERS & SWITCHGEAR | VACUUM BOTTLE TEST SETS

Vanguard DigiTMR

70 (866) 352-5550 | protecequip.com

71(866) 352-5550 | protecequip.com

M E T E R S & I N S T RU M E N TAT I O N

Test equipment for rotating machinery, such as motors and generators, play such a significant role in the health of the motor-driven world that surrounds us. Applications for this type of apparatus seem to be almost limitless and are key to ensuring that there is no interruption to the processes and conveniences of today’s world. Additionally, Protec maintains an inventory of metering products that are applicable for the purpose of quantifying the components of electrical signals (V, I, Ω, Z, W, VA, Wh, VAh etc.) including their relational characteristics such as phase angle and rotation. When testing areas of instrumentation and controls, contact Protec for oscilloscopes, power supplies, solar metrics, multifunction process calibrators, barometers, thermal metrics (IR cameras), RTD simulators and much more.

METERS & INSTRUMENTATION | BORESCOPES

B o r e s c o p e s

Extech HDV640

• Articulating probe tip adjusts up to 240o viewing angle

• 5.7” color LCD TFT with HD 640 x 480 VGA pixel presentation

• SD memory card included to store more than 15,000 images

• AV output for viewing images on a monitor

• 65 FOV

• Working length is 1m

Extech HDV640HD VideoScope Articulating Probe

Olympus IPLEX RT

• Compact and portable design

• Two hour battery life

• 6.5” monitor

• Truefeel articulation provides a precise and controlled bend at the distal end

• 5m in length

• 6mm scope diameter

Olympus IPLEX RTVideoscope

72 (866) 352-5550 | protecequip.com

METERS & INSTRUMENTATION | CAPACITANCE & INDUCTANCE METERS

ABB CB-2000

• Compact, self-contained capacitor bank analysis

• Permits measurements of individual capacitors without breaking connections

• Battery operated and easily portable

• On-board memory can be transferred to a PC for report generation or data trending and analysis

• Data from PC can be transferred to CB-2000 for on the spot analysis

• Available with large, wide-jaw current probe to accommodate a wide variety of capacitor bushings

ABB CB-2000Portable Capacitance Meter

B&K Precision 885

• Dual LCD display

• Fully automatic/manual selection

• DC resistance measurement

• Measurement parameters: Z, L, C, DCR, ESR, D, Q and q

• Infrared RS-232 interface capability

B&K Precision 885LCR/ESR Meter

C a p a c i t a n c e & I n d u c t a n c e M e t e r s

73(866) 352-5550 | protecequip.com

METERS & INSTRUMENTATION | DECADE BOXES

D e c a d e B oxe s

AEMC BR07

• Accuracy of 1%

• Range of 1 to 10 megaohms

• Seven decades

AEMC BR07Decade Box

General Resistance DA-RTD-200

• Absolute accuracy of 0.02%

• Range of 20 to 1121.1 ohms

• Five decades

General Resistance DA-RTD-200Decade Box

Time Electronics 1051

• Accuracy range from 0.1 to 10%

• Range of 0 to 1 megaohms

• Eight decades

Time Electronics 1051Resistance Decade Box

74 (866) 352-5550 | protecequip.com

COSA Xenataur XPDM

• Handheld

• Battery-operated

• HTF sensor technology

• Single point calibration

• Extremely fast response

• Simple user interface consisting of a digital LCD display, and four push buttons

COSA Xentaur XPDMPortable Dew Point Meter

Vaisala DM70

• Accurate, fast measurements for SF6 or transformer nitrogen blanket applications

• Measures temperature, dew point, absolute humidity and relative humidity

• Available sampling cell and fitting kit

• Measurement ranges from -60 to 60°C (-76 to 140°F) and 40 to 200K ppm

Vaisala DM70Dew Point Analyzer

METERS & INSTRUMENTATION | DEW POINT & HUMIDITY ANALYZERS

D e w Po i n t & H u m i d i t y A n a l y z e r s

75(866) 352-5550 | protecequip.com

METERS & INSTRUMENTATION | DRY BLOCK CALIBRATORS

D r y B l o c k C a l i b ra t o r s

Manufacturer Model Temperature Range

Ametek CTC-650A 122°F to 1,202°F 50°C to 650°C

Hart Scientific 9100S 95°F to 707°F 35°C to 375°C

Hart Scientific 9100S-A 95°F to 752F 35°C to 400°C

Hart Scientific 9103-A -13°F to 284°F -25°C to 140°C

Hart Scientific 9140-A 95°F to 662°F 35°C to 350°C

Hart Scientific 9141-A 95°F to 1,202°F 35°C to 650°C

76 (866) 352-5550 | protecequip.com

METERS & INSTRUMENTATION | INFRARED SURVEY

I n f ra r e d S u r vey

FLIR T440

• 320 x 420 Pixel IR resolution

• MSX® enhancement to thermal images adds visible spectrum definition to IR images in real time

• 3.1 megapixel visual camera with on-board video lamp and laser pointer

• Delta T and multiple measurement spots

• 60-second voice recording or on-screen annotations

FLIR T440Thermal Imaging Camera

FLIR T530

• 180° rotating optical block for imaging targets at any angle

• 320 x 240 pixel IR resolution

• 42° lens

• Infrared time lapse from 10 seconds to 24 hours

• Two programmable buttons for ease of use

• 60-second voice recording or on-screen annotations

FLIR T530Professional Thermal Camera

FLIR C2

• 45° field of view

• Stores 4,800 individual thermal measurements you can analyze and edit using FLIR Tools software

• Temperature range: -10°C to 150°C (14°F to 302°F)

FLIR C2Compact Thermal Camera

77(866) 352-5550 | protecequip.com

FLIR T640

• Optical block rotates 120o for easier targeting

• 640 x 480 pixel IR resolution

• Audible difference temperature alarm

• 60-second voice recording or on-screen annotations

• Connect via WiFi to FLIR Tools mobile for image analysis and sharing

FLIR T640Thermal Imaging Camera

Fluke Ti55

• Field rugged and optimized for use in harsh environments

• Crisp, clear images with a 320 x 240 sensor

• Fluke’s NETD thermal sensitivity identifies minute differences in temperatures

• Merge infrared and real light images for image location identification and effective reporting through IR Fusion® technology

• Emissivity correction, single hand focus capability and temperature compensation

Fluke Ti55Thermal Imager

Mikron 7200V

• Ergonomically designed for comfortable one-handed point-and-shoot operation

• Includes on-board digital voice recording

• Can simultaneously record HD 14-bit thermal images with digital visual images

• Three temperature ranges from -40C to 2,000C

• Field of view: 29o x 22o

Mikron 7200VInfrared Camera

METERS & INSTRUMENTATION | INFRARED SURVEY

I n f ra r e d S u r vey

78 (866) 352-5550 | protecequip.com

METERS & INSTRUMENTATION | MOTOR & SEMICONDUCTOR ANALYZERS

M o t o r & S e m i c o n d u c t o r A n a l y z e r s

Iris Power ELCID

• Provides rapid testing of the machine, often less than one work shift for turbo generators and motors

• Minimize intrusive repairs by instantly verifying the results

• Fast test scanning (Up to 120mm/sec at 60Hz)

• User-friendly LCD display to guide user operation

• Easily identifies hot spots via color map display

Iris Power ELCIDElectromagnetic Core Imperfection Detection Test Set

Iris Power SWA

• Allows maintenance personnel to easily and effectively assess the tightness of stator wedges in motors or generators

• Two operational modes: Standard and Advanced

• In-depth analyzing capabilities

• Printing of results

• Ability to export test data to spreadsheets, databases or word processors

Iris Power SWAStator Wedge Analyzer

Fluke 9040

• Effective for measuring phase rotation in all areas where three-phase supplies are used to feed motors, drives and electrical systems

• The unit is a rotary field indicator and can provide clear indication of the three-phase via an LCD display and the phase rotation direction to determine correct connections

• Allows rapid determination of phase sequence and has a voltage up to 700V and frequency range suitable for commercial and industrial applications

Fluke 9040Phase Rotation Indicator

79(866) 352-5550 | protecequip.com

Larkin Power M3K

• Identify and replace only marginal or bad components

• Components are testes for forward and reverse leakage current at voltages up to 3,300V

• Oscilloscope output provides the ability to observe the voltage/current curve on a X-Y oscilloscope

• Short current limited to 20mA for operator safety

• Tests components according to JEDEC JC-22 and EIA RS-397 test standards

Larkin Power M3KSemiconductor Tester

PdMA MCE

• Offers the most versatile approach to troubleshooting and trending de-energized electric motors

• Monitors power circuit insulation, stator, rotor and air gap

• Variable test voltage from 250V to 5,000V

• Automatic IR, PI, DAR and Step Touch voltages

• Measures capacitance and inductance

PdMA MCEMotor Circuit Evaluator

Megger 560400

• Provides complete phase-sequence and motor rotation testing

• Ensures correct phase hookup in one easy test

• Determines phase rotation or sequence of energized power circuits

• Rugged, portable case with handle and removable lid

• Input frequency: 25Hz / 50Hz / 60Hz / 400Hz

Megger 560400Phase Rotation Tester

METERS & INSTRUMENTATION | MOTOR & SEMICONDUCTOR ANALYZERS

M o t o r & S e m i c o n d u c t o r A n a l y z e r s

80 (866) 352-5550 | protecequip.com

SKF Baker AWA-IV/12

• The go-to instrument for motor repair, reliability and maintenance professionals who need to understand the electrical condition of motors

• Performs the following tests:

y Winding resistance

y Insulation resistance

y Dielectric analysis

y Polarization index

y DC step-voltage

y DC continuous ramped

y DC hipot

y Surge

SKF Baker AWA-IV/12Static Motor Analyzer

METERS & INSTRUMENTATION | MOTOR & SEMICONDUCTOR ANALYZERS

M o t o r & S e m i c o n d u c t o r A n a l y z e r s

SKF Baker PP30

• Increase the test capability of the Baker AWA-IV by coupling it with the PP30

• Produces up to 30kV for testing of high-voltage windings, and has three switchable test leads for simple connections to three-phase apparatus

• Features large pneumatic wheels for easy transport to testing areas

SKF Baker PP30Power Pack

PdMA MCEMAX™

• Monitors power circuit insulation, stator, rotor and air gap

• Equipped with a fully functional laptop computer and loaded with MCEGold®

• Variable test voltage from 250V to 5,000V

• Automatic IR, PI, DAR and Step Touch voltages

• Measures capacitance and inductance

• Six channel simultaneous acquisition

• Torque and efficiency analysis

• Impedance and phase angle measurement

• Power and current signature tests

PdMA MCEMAX™

Motor Circuit Evaluation Analyzer

81(866) 352-5550 | protecequip.com

METERS & INSTRUMENTATION | MULTIFUNCTION MULTIMETERS

M u l t i f u n c t i o n M u l t i m e t e r s

Manufacturer Model Description

Amprobe ACD-15 TRMS-PRO Digital clamp-on multimeter

Arbiter 928A Single-phase power system multimeter with current probe

Emerson 475/475FB Comprehensive field communicator with fieldbus

Fluke 43B Single-phase power quality meter

Fluke 87V Industrial multimeter

Fluke 190-204/S Four-channel oscilloscope

Fluke 192 Two-channel oscilloscope

Fluke 435 Three-phase power quality and engery analyzer

Fluke 754 Documenting process calibrator for HART troubleshooting

Fluke 787 Digital multimeter with loop (process) calibrator

Fluke 810 Comprehensive vibration metering test set

Fluke 1587 FC Advanced electrical troubleshooting kit

Megger PMM-1 Power multimeter

82 (866) 352-5550 | protecequip.com

METERS & INSTRUMENTATION | POWER SUPPLIES

Po w e r S u p p l i e s

• Small, lightweight and portable AC and DC power supply

• Intended for resetting circuit breaker charging motors and other general-purpose applications

• Provides DC voltage in three nominal ranges from 0 to 120V, 240V, and 480V at 1VA

• AC voltage in three nominal ranges from 0 to 140V, 280V, and 560V at 1.4kVA

Electrical Test Instruments ETI ACDC-10AC and DC Power Supply

ETI ACDC-10

Simran SIM-3000

• 3,000W maximum capacity, heavy-duty continuous use transformer

• Converts 110V / 120V to 220V / 240V and vice versa

• Four outlets on the front, an insulated power cable, and outlet adapters for global applications

Simran SIM-3000Step Up/Down Voltage Transformer

ETI AD-1/AD-2

• Portable variable AC/DC power supply

• AC and DC voltage ranges: 0 to 120, 240, and 480 Volts at 1kVA

• Rugged metal suitcase style case

Electrical Test Instruments ETI AD-1/AD-2AC and DC Power Supply

83(866) 352-5550 | protecequip.com

Vanguard UPS-S2

• Current capability of 10A continuous in either AC or DC voltage ranges

• Variable DC output voltage of 300Vdc max

• Variable AC output voltage of 240VAC max

• 110V line powered

• Approximately 55 lbs

Vanguard UPS-S2Universal Power Supply

• Single-phase, three-phase and three-phase variacs for 120V, 240V and 480V applications

• Continuous adjustable output voltages from AC power lines without wave form distortion or SCR generated noise

• Dependable and accurate AC control device

• Can be operated at frequencies between 50Hz and 2,000Hz with derating at higher than rated frequency

• Shaft is fully adjustable and can be extended from either end for general utility mounting

Staco 1520-3/C-3Variable Transformer

Staco 1520-3/C-3

METERS & INSTRUMENTATION | POWER SUPPLIES

Po w e r S u p p l i e s

84 (866) 352-5550 | protecequip.com

METERS & INSTRUMENTATION | PHOTOVOLTAIC / SOLAR MONITORING

P h o t ovo l t a i c / S o l a r M o n i t o r i n g

HT Instruments I-V400w

• Ideal for commissioning, performance testing and troubleshooting photovoltaic (PV) installations

• Provides measurement of IV curve of one or more modules or of complete string up to 1,000V / 10A

• Mechanical inclinometer for incidence angle of solar irradiation

• Numerical and graphical display of IV characteristics

• Uses four-terminal measurement method

• Measurement of open-circuit voltage and short-circuit current Voc/Isc

• On-board database of 30,000 selectable photovoltaic modules

• Automatically determines efficiency comparison to manufacturer data

• Immediate and clear indication of compliance upon test completion

• Internal memory for results storage and review or download

• On-board optical and USB port for PC connection

HT Instruments I-V400wCurve Tracer

Seaward PV150

• Allows electrical safety and performance verification of photovoltaic installations in a safe and easy-to-use test set

• Combines ground continuity, DC operating power and operating current test functions in a hand-held device

• Unit can wirelessly capture and record real-time irradiance, ambient temperature and PV module temperature measurements from the Solar Survey 200R

Seaward PV150Solar Installation Tester

Seaward Solar Utility Pro

• Tests parallel wired strings up to a maximum of 1500V / 40A

• Direct MC4 connections, with the option to add a conversion lead set for safer connections in combiner boxes

• A single press of the Test button will give values for Open Circuit Voltage and Short Circuit Current

Seaward Solar Utility ProComplete Solar Testing Kit

85(866) 352-5550 | protecequip.com

METERS & INSTRUMENTATION | WATTHOUR METERS

Wa t t h o u r M e t e r s

Radian Research RB-10

• Versatile single-phase standard with typical accuracy of 0.005% throughout operating range

• Integrated analog to digital signal converter for real-world waveform measurement

• Four-quadrant measurement registers forward and reverse energy flow and documents voltage, current, power and energy (active, reactive, and apparent)

• Optional harmonic analysis through 50th harmonic order

• Built-in comparator provides automatic calculation of test results

• BNC for input/gating, pulse outputs and phase sync or analog sense

• Intuitive five button user interface for setup of measurement, test sequence, and harmonics

• Seamless integration with radian accessories

Radian Research RB-10Bantam Lite Portable Test Kit

Scientific Columbus SC10

• Full auto-ranging for current and potential inputs and auxiliary power

• Backlit LCD readout

• A maximum resolution to 0.00001Wh

• Supports closed-link testing of solid state and electromechanical meters

Scientific Columbus SC10Watthour Standard Meter

86 (866) 352-5550 | protecequip.com

87(866) 352-5550 | protecequip.com

PARTIAL DISCHARGE | OFF-LINE TEST SETS

PA RT I A L D I S C H A RG E

When operating with high voltage equipment the use of Partial discharge (PD) detection equipment is necessary. Partial discharge is a localized dielectric breakdown of a small portion of a solid or liquid electrical insulating system under high-voltage field stress, which does not bridge the space between two conductors. If left unattended, partial discharge often leads to a failure of the electrical insulating system. To detect PD in the early stages, or to determine source location, periodic diagnostic PD measurements are recommended. Reliable and long-term operation of high voltage equipment can only be assured by PD prevention and detection. Protec carries and inventory of test equipment for all your partial discharge testing needs.

O f f - L i n e Te s t S e t s

HV Diagnostics High Voltage Sourcesfor Off-Line PD Analysis

ModelOutput Volt-

ageInput Pieces

Total Weight

TypicalApplication

HVA34 34kV VLF 120V 1 44 Lbs 15kV Cable

HVA60 60kV VLF 120V 1 126 Lbs 35kV Cable

HVA90 90kV VLF 120V 1 280 Lbs 46kV Cable

HVA120 120kV VLF 240V 1 436 Lbs 69kV Cable

PDTD60 60kV VLF 120V 2 347 Lbs 69kV Cable

PDTD120 120kV VLF 120V 2 90 Lbs 35kV Cable

HV Diagnostics PDTD120

88 (866) 352-5550 | protecequip.com

Ofil Systems DayCor Superb-OD

• Accurately pinpoints sources of corona, partial discharge, micro arcing and arcing that may lead to: audio noise, radio/TV interference and electrical mechanical failures

• An anatomically form-fitted harness distributes the camera’s weight and allows extended inspection intervals

• Built-in recording, playback and storing of high-resolution video clips with voice annotations and still pictures

• Bi-spectral solar blind UV-visible camera allowing operation in full daylight

Ofil Systems DayCor Superb-ODCorona Camera

O n - L i n e Te s t S e t s

PARTIAL DISCHARGE | ON-LINE TEST SETS

EA Technology CableDataCollector

• Identifies and allows you to report on PD activity in live MV/HV cable networks

• Detects and measures PD activity in single and three-phase cables

• Works with all insulated cable types

• Quick assessment of a large number of cables to build up a total view of the condition of a distribution cable network

• Quickly highlights cables that require more detailed analysis techniques

EA Technology CableData CollectorPartial Discharge Analyzer

EA Technology UltraTev Plus2

• Quickly identify presence and severity of PD in electrical apparatus

• Baselines PD activity to direct maintenance activities

• Measures surface PD as numerical dB values and measures internal partial discharge as Transient Earth Voltage (TEV) values

• Automatically grades condition of TEV and ultrasonic values for immediate analysis

EA Technology UltraTev Plus2Multifunction Partial Discharge Analyzer

89(866) 352-5550 | protecequip.com

• One instrument solution for a wide variety of substation apparatus and cables

• Represents the latest technology in both electromagnetic and acoustical sensors to identify and find PD in energized substations and switchgear

• Available with Ultra High Frequency (UHF), Transient Earth Voltage (TEV), High Frequency CT (HFCT or RFCT), acoustical contact and airborne acoustic sensors

• Sensors are wireless where appropriate so operator can maintain safe approach distances

• Hand-held instrument is small, lightweight and portable

• Short learning curve — operators can become proficient in minutes

• Instrument identifies specific PD type: void, corona, surface, particle or floating electrode

• Phase resolved display documents PD over the sine wave to ensure measured PD is from the circuit under test and not background or nominal noise

• PRPD (2D) and PRPS (3D) compare UHF and HFCT signals to local power signal

• AE and ultrasonic values displayed as RMS, peak, frequency content (x1 and x2), phase, pulse and wave spectrum

• Wireless line synchronization is accomplished using the instrument charger

• Suitable for use on power cables, transformers, GIS, switchgear and other substation apparatus

• Available with PDetector software to catalog and trend results and produce professional reports

• Programmable alarms document exact PD signature so reports are clear to those unfamiliar with PD testing

• Software exports results to Excel or PDF

• On-board RFID asset tagging and intelligent patrol functions automatically document the specific substation assets being tested

PMDT PDetectorHandheld Partial Discharge Detector

Sonel UV-260

• High sensitivity to UV signals

• Precise location of corona-emitting sources

• UV events alarm and counter

• Still image capture and review

• Built-in GPS documents test location

• UV-260 PC software for reports

Sonel UV-260Corona Camera

O n - L i n e Te s t S e t s

PARTIAL DISCHARGE | ON-LINE TEST SETS

PMDT PDetector

90 (866) 352-5550 | protecequip.com

91(866) 352-5550 | protecequip.com

P O W E R Q UA L I T Y

As electrical power systems grow and become more complex, power quality has become a topic of growing concern. The IEEE defines power quality as “the concept of powering and grounding sensitive equipment in a manner that is suitable to operation of the equipment.” In short, power quality equals reliability and reliability equates to dollars saved. Some of the known impacts of poor power quality have related to unplanned interruption of power and production processes, overheating and reduced life cycles of machinery, damage to sensitive equipment, interference with communications and increased electrical system losses. In order to strategically address the specific power quality issues that challenge the reliability of the electrical system, we must first identify what those specific challenges are. Power quality monitoring equipment is used to identify such quantities as voltage sags and swells, as well as transients, harmonic distortion and unbalanced loading. Protec maintains a complete range of power quality test and monitoring products to maintain, protect and service the reliability of your electrical power systems.

POWER QUALITY | DATA ACQUISITION

D a t a A c q u i s i t i o n

Astro-Med (AstroNova) TMX-18

• Optimal for load step tests, generator and UPS commissioning

• Record any input signal at user defined sample rates up to 800KHz

• Monitors AC or DC voltage directly to 1kV, or precision analysis at mV levels

• Derived channels for mathematical comparisons of input values

• Daisy chain TMX units together for 96 contemporaneous channel recordings

Astro-Med (AstroNova) TMX-1818-Channel Data Acquisition System

DENT ELITEpro

• Records four channels of current and three channels of voltage

• User defined sample rate from three seconds to 24 hours

• ELOG software for recorder configuration, data retrieval, analysis and report generation

• Measures and records voltage (AC or DC), current (AC or DC), frequency, kW, kWh, kVA, kVAh, kVAR, kVARh and power factor

• Available with the user’s choice of current probes

DENT ELITEproPower Datalogger

92 (866) 352-5550 | protecequip.com

POWER QUALITY | POWER QUALITY ANALYZERS

Amprobe DM-5

• Simultaneously measures power, harmonics, waveform and power quality (voltage: three-channel, current: four-channel)

• Record power quality events such as swells, dips, interruptions, transients, inrush currents and flickers

• Automatic recording with memory for up to 1,000 parameters at user defined intervals

• Voltage (RMS) range: 600Hz / 1,000V

• Comes complete with measurement accessories, PC software, large carrying case and a Protec provided laptop computer

Amprobe DM-5Power Quality Analyzer

AEMC PEL 105

• Measures nearly every circuit type including single-phase, split-phase, three-phase (multiple types) and DC circuits

• Suitable for use in 50Hz / 60Hz, 400Hz and DC applications

• Available with a wide variety of current probes

• Current measurement from 200mA (for CT secondaries) up to 10,000A AC or 5,000A DC

• Direct voltage measurements to 2,000V phase-to-phase or 1,000V phase-neutral

• Measures power: kVA, kW and kVAR

• Permits configuration of ratios for medium or high voltage PT and CT secondary circuit

AEMC PEL 105Power and Energy Logger

Po w e r Q u a l i t y A n a l y z e r s

AEMC PEL 103

• Reports generated with minimal configuration time and effort.

• Can be installed inside a load center panel (including the current sensors) allowing the door to close on most panels

• Measures and records three True RMS voltage inputs and current inputs, Watts, VARS, VA and Energy (kWh and kVA)

• Power Factor (PF), Displacement Power Factor (DPF), Crest Factor, Frequency and THD are calculated and recorded

• Individual harmonic % information from 1 to the 50th harmonic are recorded at the operator’s choice

• All variables are recorded and stored at a one second interval and on user selectable demand intervals from 1 to 60 minutes

AEMC PEL 103Power and Energy Logger

The PEL Power Adapter is also available for use with this unit.

93(866) 352-5550 | protecequip.com

Po w e r Q u a l i t y A n a l y z e r s

Arbiter 930A

• Basic accuracy of 0.05% of reading and 0.05° of phase for full three-phase power analysis capability

• Long life battery (more than 8-hour continuous run time) and smaller than a lunchbox

• Datalog to internal memory or export by serial with real-time time/date stamps

• Measures voltage and current, phase angle, frequency, harmonics, waveform and power/energy values

Arbiter 930APower Analyzer

POWER QUALITY | POWER QUALITY ANALYZERS

Manufacturer Model Description

Dranetz Dranflex (Green) Flexible CT; 30A, 300A, and 3,000A (24”)

Dranetz Dranflex (Red) Flexible CT; 300A and 3,000A (24”)

Dranetz Dranflex 36 Flexible CT; 300A, 3,000A (36”)

Dranetz Dranflex 48 Flexible CT; 300A, 3,000A (48”)

Dranetz Dranflex 348 Flexible CT; 3,000A 3-in 1 CT (48”)

Dranetz Dranflex6K Flexible CT; 6,000A (24”)

Dranetz Dranflex6K36 Flexible CT; 6,000A (36”)

Dranetz Dranflex HD Flexible CT; 3,000A

Dranetz Dranflex HD3 Flexible CT; 3,000A 3-in-1

Dranetz PR150SP1 150A AC/DC current probe

Dranetz PR1500SP 1,500A AC/DC current probe

Dranetz TR2510 10A rigid current probe

Fluke 3035A Flexible, 30A/300A/3,000A (24”)

Fluke 3035A3 Flexible, 30A/300A/3,000A (36”)

Dranetz HDPQ Xplorer/ PowerExplorer PX5

• High speed monitoring, data and waveform capture, up to one microsecond/ channel of all power, energy, distortion and power quality parameters

• Automatic circuit type verification to minimize erroneous data recording sessions

• Comprehensive control of thresholds, triggers and monitoring parameters

• Powerful reporting software, Dranview Professional or Dranview Enterprise, for in-depth and comprehensive reporting and analysis

• Current ranges from 0.01A to 6,000A with available current probes

Dranetz HDPQ Xplorer/PowerExplorer PX5Power Quality Analyzer/Power Monitor

Dranetz HDPQ Xplorer/PowerExplorer PX5 Compatible Current Probes

Available with Summit Technology 15KVP current probes & other

high voltage probe sets

94 (866) 352-5550 | protecequip.com

POWER QUALITY | POWER QUALITY ANALYZERS

Fluke 43B

• Measures and trends single-phase voltage to 1kV, current to 3,000A, frequency, power harmonics, voltage sags, transients and current inrush

• Record two selectable parameters for up to 16 days

• Internal measurement of 20 parameters

• Available with FlukeView software

Fluke 43BSingle-Phase Power Quality Analyzer

Po w e r Q u a l i t y A n a l y z e r s

Fluke 434/435

• Measures three-phases with neutral at 200kS/s on each channel simultaneously

• Available with a wide variety of current probes from 5A (for monitoring secondaries) to 5,000A flexible current probes

• Measures and records:

y Voltage (AC and DC) to 1,000V

y Current (AC and DC) to 5,000A

y Peak voltage and peak current

y Crest factor

y Frequency

y Dips and swells

y Harmonics

y Power and energy

y Flicker

y Unbalance

• Internal memory records five readings/second continuously per channel

• Interharmoics, advanced energy, transient and inrush are available on Fluke 435

Fluke 434/435Three-Phase Power Quality and Energy Analyzer

Manufacturer Model Type Range Jaw Opening

Fluke i200s Rigid Dual: 100mA to 24A, 500mA to 200A 3/4"

Fluke i30s Rigid Single: 30mA to 20A 3/4"

Fluke i400s Rigid Dual: 500mA to 40A, 5A to 400A 1-1/4"

Fluke i5s Rigid Single: 5A to 400A 5/8"

Fluke i5sPQ3 Rigid Single: 10mA to 6A 5/8"

Fluke i600s Rigid Three: 6A to 60A, 60A to 600A, 600A to 600A 8"

Fluke 434/435 Compatible Current Probes

95(866) 352-5550 | protecequip.com

Po w e r Q u a l i t y A n a l y z e r s

Fluke 1735

• Easily confirm instrument setup with color display of waveforms and trends

• Measure all three-phases and neutral with included four flexible current probes

• Current probes are connected with one plug, and the instrument automatically detects, scales and powers the probes

• Easily set current probes to 15A, 150A or 3,000A for high accuracy in nearly any application

• Sample rate of 10.24kHz

Fluke 1735Three-Phase Power Quality Logger

POWER QUALITY | POWER QUALITY ANALYZERS

Fluke 1736

• The ideal test tool for conducting energy studies and basic power quality logging

• Automatically capture and log over 500 power quality parameters so you have more visibility into the data you need to optimize system reliability and savings

• Includes four flexible current probes

• Perform convenient in-the-field analysis and data checks with full graphical display on its bright, color touch screen

• Sample rate of 10.24kHz

Fluke 1736Three-Phase Power Quality Logger

96 (866) 352-5550 | protecequip.com

POWER QUALITY | POWER QUALITY ANALYZERS

Po w e r Q u a l i t y A n a l y z e r s

Summit Technology PowerSight PS3550

• A true hand-held three-phase power analyzer

• 68 different measurement types for regular recording of voltage, current, power, apparent power, true power factor, frequency, and THD

• Has Bluetooth and USB communication capability

• Surestart makes unit simple to use and setup as it provides you with warning of potential connection issues and operational setting prior to monitoring

• Rechargeable battery operation for eight hours between charges

Summit Technology PowerSight PS3550Power Analyzer

• Quick communications and configuration using Bluetooth-enabled device

• Threshold free setup — apply thresholds after monitoring is complete using Fluke’s intuitive Power Analyze Software

• Five voltage and five current inputs enable separate ground and neutral motoring

• Monitors all power, energy, distortion and power quality parameters with harmonic measurement to the 50th order

• Available with appropriately ranged current probes

Fluke 1750Three-Phase Power Quality Logger

Manufacturer Model Description

Fluke 3310 5,000A Flex CT

Fluke 3140R 2 400A AC clamps

Fluke I5SPR 5A Clamp CT

Fluke 1750 Compatible Current Probes

Fluke 1750

Optional laptop/tabletprovide by Protec

97(866) 352-5550 | protecequip.com

Hioki PW3196/PW3198

• Perform long-term measurements of the power quality and study problems that are difficult to detect or that occur intermittently

• Manage the parameters with a control set point, such as a voltage fluctuation, flicker, and harmonic voltage

• Easy to set up — just select the measurement course and the unit will do the rest

• Four current and four voltage input channels

• Approximately three hours of charge when running on battery life

• Comes with one clamp-on current probe (500A AC), and three flexible current probes (500A to 5,000A AC)

Hioki PW3196/PW3198Power Quality Analyzer

Po w e r Q u a l i t y A n a l y z e r s

POWER QUALITY | POWER QUALITY ANALYZERS

98 (866) 352-5550 | protecequip.com

R E L AY & P ROT E C T I O N

A significant portion of electrical power system protection of is supervised by protective relays. These devices are often the decision-making component of power system protection. They accomplish this by monitoring and analyzing conditions within their zone of protection. If they sense abnormal or fault conditions then they send signals telling other devices to interrupt or isolate the faulted circuit. These relays have evolved from a simpler electromechanical design to the more complex microprocessor-based devices that are common protection engineers today. However, if they fail to operate properly or not configured appropriately for their intended application, then they could be providing a false sense of security in conditions where the power system is left vulnerable and unprotected. Verifying settings and the proper operation of protective relays should be part of a planned testing and maintenance program. Not only do these devices need to be verified during acceptance, but periodic testing should be done to confirm their operation in response to ever growing and changing electrical systems. Protec supplies the relay and protection equipment to meet your testing needs.

99(866) 352-5550 | protecequip.com

RELAY & PROTECTION | COMMUNICATIONS ANALYZERS

C o m m u n i c a t i o n s A n a l y z e r s

PowerComm PCA-4125

• Single unit with all power communications functions:

y Selective level meter

y Signal generator

y Impedance meter

y VSWR and LCR meter

y Frequency response analyzer

y Oscilloscope

• Field ready and complete with fittings and accessories

• Save, recall and download field test setups and results

• Available with power line carrier simulator and complete adapter/connector set

PowerComm PCA-4125Power Communications Analyzer

100 (866) 352-5550 | protecequip.com

RELAY & PROTECTION | SINGLE-PHASE TEST SETS

Doble F2253

• Multiple output configurations, including one voltage and one high VA current or two currents

• Voltage output up to 300VAC (phase to ground) or 424VDC continuous

• On-board timer, phase shifter and frequency generator

• Current output up to 90A AC or 60A DC continuous

• Optional Doble F2010 mini controller available for fine frequency adjustments and remote control

Doble F2253Single-Phase Relay Test Set

S i n g l e - P h a s e Te s t S e t s

Accessory Description

F6051 F6150 time synchronizer

F6071 F6150 infrared optical pickup

F6300e External amplifier (see page 100)

F6895 F6150 GPS module

RTS7 Key Available with Protec laptop

101(866) 352-5550 | protecequip.com

T h r e e - P h a s e Te s t S e t s

• Simple manual testing through control panel software

• F6150SV model is optimized for testing IEC 61850 based protection devices (GOOSE protocol) at the process-bus level and station-bus level using sampled values and GOOSE messages

• Both F6150E and F6150SV models include WiFi

• Available with a preconfigured laptop computer or Doble DUC with appropriate leads and connections for most relay testing applications

• Standard configuration includes three 300VAC outputs and three 30A outputs simultaneously

• Software adjustment permits a variety of other configurations, including four voltages and four currents, a single current at 675VA and much more

• Variable phase angle, frequency generation, phase shifting and on-board DC

• Suitable for testing 0.2 class metering CTs and transducers

• Source for energizing relays before control power is available

• Includes Doble Transwin software for COMTRADE configuration file (.cfg) playback

• Optional satellite antenna provides for end-to-end testing

• Optional F6051 component enables end-to-end testing with access to station time clocks

• Optional Doble F6300 increases current output and quantity of channels

Doble F6150svPower System Simulator with GOOSE

F6150, F6150E models & various variants also

available

RELAY & PROTECTION | THREE-PHASE TEST SETS

Doble F6150sv Compatible Accessories

Doble F6150sv

102 (866) 352-5550 | protecequip.com

T h r e e - P h a s e Te s t S e t s

RELAY & PROTECTION | THREE-PHASE TEST SETS

Doble F6300e

• Used with a power system simulator for critical high burden relay testing

• 12 enhanced current sources for running high burden and amplitude faults

• Test bus power system models up to six current nodes

• Multiple sources in one amplifier reduce the number of boxes needed for testing

• Works with Doble Protection Suite or third party software

Doble F6300eExternal Amplifier

Megger SMRT36

• Three convertible channels (300V or 15A), three 60A channels, 10 binary inputs and 6 binary outputs

• Bluetooth, USB or Ethernet communication between SMRT36 and computer

• Megger’s Smart Touch View Interface (STVI) provides simple touchscreen graphical interface for testing most relays

• High current output suitable for modern and electromechanical applications

• Complex impedance testing simplified with built-in relay library

Megger SMRT36Relay Test System

Manta MTS-5100

• Automatic reporting with no external software or PC required

• Operation with or without PC, steady state testing, dynamic testing and transient waveform testing

• High VA output

• Six AC/DC current outputs and four AC/DC voltage outputs

• 12 contact (0 to 250V) inputs and four contact outputs

• 120V / 60Hz, 230V / 50Hz operational

Manta MTS-5100Protective Relay Test System

Megger SMRT46

• Multipurpose, lightweight, field portable test set capable of testing a wide variety of electromechanical, solid-state and microprocessor-based protective relays, motor overload relays and similar protective devices

• Intuitive manual operation with Smart View Interface

• 60Amps / 300VA RMS per phase

• Four voltage channels, three current channels, with convertible voltage channels provides one voltage and six currents

Megger SMRT46Multi-Phase Relay Test System

Megger SMRT410

• Offers the “Smart” combination of high compliance voltage and high current output to test all electromechanical, solid-state and microprocessor-based overcurrent relays

• Intuitive manual operation with Smart Touch View Interface

• High current, high power output (60Amps / 300VA RMS) per phase

• Flexible output design provides up to four-phase voltage and up to 10-phase current

• Fully automated testing using AVTS software

Megger SMRT410Relay Test System

103(866) 352-5550 | protecequip.com

T h r e e - P h a s e Te s t S e t s

RELAY & PROTECTION | THREE-PHASE TEST SETS

RCP1 (19 Pin)RST1 (14 Pin) RVT1 (32 Pin)

• Standard configuration includes six current outputs (in three-phase mode, 64A/860VA per channel or one channel at 128A / 1,000VA) for maximum flexibility and range of applications

• Optional GPS or IRIG-B accessories for end-to-end testing

• Simulates transient faults, power swing, CT saturation, CB or Rogowski coil simulation

• 10 binary inputs (dry/wet)

• On-board 10-channel recorder for typical power values, transients, trend recordings and harmonic analysis

Omicron CMC 356Universal Relay Test Set and Commissioning Tool

Omicron CMC 356

Omicron Recloser Control Cable Packages

104 (866) 352-5550 | protecequip.com

105(866) 352-5550 | protecequip.com

TRANSFORMER TEST & DIAGNOSTICS | CURRENT TRANSFORMER TEST SETS

T R A N S F O R M E R T E S T & D I AG N O S T I C S

Transformers are an essential component of the electrical power system. They are at the very heart of electrical power distribution systems. Misoperation or failure of these components not only have the potential for limiting the ability to deliver electricity, but could also result in very costly damages to the power system and its components. If maintained and serviced regularly transformers can be extremely reliable and provide service for long periods of time. It is therefore important to have a well-planned testing and maintenance routine that will ensure the longevity and reliability of these critical power system components. Since replacement of a large transformer can take as much as a year or more, diagnostics and trending tests can be of great value in determining a transformer’s predicted end of life and can assist in the planning of its replacement Protec offers a comprehensive range of transformer testing and diagnostics tools, from multiple manufacturers, for the purpose of ensuring the health of your assets.

C u r r e n t Tra n s f o r m e r (C T ) Te s t S e t s

Megger MRCT

Megger MRCTRelay and Current Transformer Tester

• Allows simultaneous measurement on all taps eliminating the need to test each tap sequentially and independently

• Automatically perform preset test routines on all taps without changing leads and at a single push of a button

• Multiple instantaneous saturation curves and their knee points are plotted and calculated on the fly as the test is being performed

• All test results can be stored within the MRCT where they are saved in a versatile format that can be exported into PowerDB

106 (866) 352-5550 | protecequip.com

C u r r e n t Tra n s f o r m e r (C T ) Te s t S e t s

TRANSFORMER TEST & DIAGNOSTICS | CURRENT TRANSFORMER TEST SETS

Raytech CT-T1

• Microprocessor-based CT test system measures CT excitation, current ratio and winding polarity

• Single connection harness permits all taps to be tested automatically, without user intervention

• Measures ratios from 0.9 to 15,000:1

• 2,000V output with resolution of 10mV

• 10A current output with resolution of 0.01mA

Raytech CT-T1Current Transformer Tester

Omicron TESTRANO 600

• Tests Include:

y TTR

y Exciting current

y DC winding resistance

y Dynamic resistance

y Vector group check

y Cool down test

y Short-circuit impedance/leakage reactance

y Frequency response of stray losses

y Demagnetization

y Power/dissipation factor (with CP TD12)

y Quick test

• Powerful device with 3A x 33A DC or 400VAC

• Automatic tap changer control and measurement

Omicron TESTRANO 600Three-Phase Power Transformer Test System

Omicron CT Analyzer

• Evaluates CTs to the IEC or IEEE standard within seconds with push-to-test convenience

• Ideal for on-site, lab or factory testing and calibration of metering and protection CTs

• High measurement accuracy: 0.02% (suitable for class 0.1 metering CTs)

• Tests run at 120V to ensure operator safety

• Remote control software provides full access to all CT analyzer functions, enables saved test procedures and exports data to Excel or Word

Omicron CT AnalyzerCurrent Transformer Testing, Calibration and Assessment

107(866) 352-5550 | protecequip.com

C u r r e n t Tra n s f o r m e r (C T ) Te s t S e t s

TRANSFORMER TEST & DIAGNOSTICS | CURRENT TRANSFORMER TEST SETS

Vanguard EZCT/EZCT-10

• Measures excitation voltage and current, turns ratio, winding polarity on single-phase and multi-phase CTs

• Excitation voltages up to 1,200V, current to 2A (at 200V)

• Operation from front panel or through computer control

• Capable of testing turns ratios from 0.8 through 5,000:1

• EZCT-10 model increases excitation current to 10A (at 200V)

Vanguard EZCT/EZCT-10Automated CT Test Set

Vanguard EZCT-2000C Plus

• Fully automated testing by front panel, Android app or computer-controlled through PC software

• Automatically demagnetizes CT when performing CT excitation test

• Internal storage of test plans — easy setup of test plans or quick manual testing through front panel controls

• Connects to all secondary terminals of the CT for fully automated testing without user intervention

• Plots multiple saturation curves for comprehensive and professional report generation

Vanguard EZCT-2000C PlusAutomated CT Test Set

Vanguard EZCT-2000A

• Measures excitation voltage and current, turns ratio, winding polarity on single and multi-tap CTs

• Excitation voltages to 2,000V AC, current up to 10A (at 300V)

• Fully automated, connects to all CT output terminals simultaneously — no lead switching required

• CT ratio and excitation knee point calculated and charted automatically

• Five voltage test settings — 50V, 300V, 500V, 1,200V and 2,000V AC

• Measures DC resistance in CT windings

Vanguard EZCT-2000AAutomated CT Test Set

108 (866) 352-5550 | protecequip.com

O i l Te s t E q u i p m e n t

TRANSFORMER TEST & DIAGNOSTICS | OIL TEST EQUIPMENT

Manufacturer Model Voltage Level

Doble OTC Oil Test Cell

High Voltage DTS-60A 60kV

Megger OTS-60PB 60kV

HV Diagnostics BA-75 75kV

High Voltage DTS-100D 100kV

HV Diagnostics BA-75Doble OTC Megger OTS-60PB

High Voltage DTS-60A

• Performs repeatable, accurate measurement of breakdown voltage of insulating oils

• Three rates of rise: 500V / 2,000V / 3,000V per second

• Arc detection with automatic shutdown and measurement hold

• Window panel for observation

• Full programming and automation with on-board printer, internal results storage and RS-232 interface, user defined test sequences and temperature sensor

High Voltage DTS-60AOil Dielectric AC Test Set

109(866) 352-5550 | protecequip.com

Po w e r F a c t o r Te s t S e t s

• Rugged construction for field use with laboratory accuracy and precision

• Industry standard for testing electrical apparatus such as transformers, generators and cables

• Evaluates integrity of high voltage substation apparatus by measuring power factor/tan delta

• Measures capacitance to evaluate physical changes

• Measures accurately in high electrostatic and electromagnetic conditions

• Measures excitation current to evaluate transformer magnetizing circuit

• Line frequency modulation technology eliminates substation interference

• Automated testing procedures through DTA or manual through M4000 clipboard

• Available with an M4000 and DTA preconfigured laptop computer or DUC; and all application appropriate accessories

• Internal field calibration reference ensures accurate testing

• Built-in diagnostics provide information on instrument status

• Output current to 300mA at 10kV (total output power 3kVA) for better replication of in-service conditions

• Optional Type C resonator increases output capacity

• Optional M4110 Leakage Reactance Module available for measuring the impedance of the apparatus under test

• Optional M4140 Capacitor Bank Test Kit available for measuring capacitance of capacitor banks

• Optional liquid insulation test cell for measuring insulating characteristics of oil

• Optional TTR capacitor for measuring transformer ratio

Doble M4000/M4100Power Factor Test Set

Doble Type C

• Used in conjunction with the Doble M4000/M4100 to provide extra current needed for high voltage test levels

• Iron core reactor with adjustable air gap

• Capable of resonating capacitance of 0.05 to 1.0μF at 10kV 60Hz

Doble Type CResonating Inductor

TRANSFORMER TEST & DIAGNOSTICS | POWER FACTOR TEST SETS

Doble M4000/M4100

Doble M4110

Doble M4140

110 (866) 352-5550 | protecequip.com

Po w e r F a c t o r Te s t S e t s

Megger DELTA4310

• Fully automatic insulation power factor/dissipation factor test set up to 12kV

• Suitable for testing transformers, bushings, circuit breakers, cables, lightning arresters and rotating machinery

• Measures excitation current of transformer windings, automatic tip-up tests and HV turns-ratio testing (with optional TTR capacitor)

Megger DELTA4310Power Factor Test Set

Megger CB100

• Lightweight and portable (21 lbs)

• Output of 26V at 100Hz minimizes 60Hz interference

• Performs UST and GST configuration testing

• Direct reading of capacitance and dissipation factor

• Simple manual interface

• Optimal for transformer dry out

Megger CB100Power Factor Test Set

Megger MIT525

• Simple to use with intuitive controls and features

• Battery operated

• Performs PI, step voltage, dielectric discharge, dielectric absorption ratio automatically

• Burn and breakdown functions available in insulation resistance mode

Megger MIT525Insulation Resistance Meter

TRANSFORMER TEST & DIAGNOSTICS | POWER FACTOR TEST SETS

111(866) 352-5550 | protecequip.com

Omicron CP SB1

• Used with Omicron CPC-100 and TD-1

• Provides connections for three-phase winding resistance and three-phase TTR measurements

• Primary test manager software provides automated (sequential) testing of all phases and each tap changer position

• Permits one-time cable connections reducing time spent connecting cables

• Minimizes erroneous results with automated testing

Omicron CP SB1Switch Box for Automated Transformer Testing

Po w e r F a c t o r Te s t S e t s

TRANSFORMER TEST & DIAGNOSTICS | POWER FACTOR TEST SETS

• A complete transformer test system, including 12kV power factor tests

• Measures capacitance, dissipation factor tan δ (tan delta), power factor COS φ, watts losses, power (effective power, apparent power and reactive power), and impedance (absolute value, phase, inductance, resistance, quality) with optional CP TD1 component

• On-board computer driven test plans to replicate or trend power factor tests with existing values

• Applies up to 12kV at variable frequencies which enhances diagnosis of insulation aging

• Automatic power factor testing via Omicron’s Primary Test Manager software with the included preconfigured laptop computer or via front panel controls (includes test templates)

• Provides for automated testing of power transformers, CTs, VTs, resistance testing and more

• Optimal for emergent requirements or remote applications; one device replaces multiple instruments

• Stand alone functionality for:

y Ratio, burden and polarity, phase and magnitude error, excitation curve, winding resistance, secondary burden and dielectric withstand tests for CTs and PTs

y Ratio, winding resistance, tap changer testing, excitation current, short circuit impedance measurement and leakage reactance testing of transformers

y Contact resistance, winding resistance, ground resistance or measurement of complex impedances

y Single-phase testing of primary and secondary relays (including overcurrent, overvoltage, undervoltage and frequency relays)

• 2kV AC voltage source current source to 400A DC and 800A AC

• Optional CP CB2 boosts current output to 2,000A AC

• Optional CP TD12 for performing power/dissipation (tan delta) factor and capacitance measurements

• More CPC-100 accessories available on pages 32, 33 and 49

Omicron CPC 100Multifunctional Primary Test System

Omicron CP B2

Omicron CP TD1

Omicron CPC 100

Omicron CP TD12

112 (866) 352-5550 | protecequip.com

S w e e p Fr e q u e n c y R e s p o n s e A n a l y z e r s

TRANSFORMER TEST & DIAGNOSTICS | SWEEP FREQUENCY RESPONSE ANALYZERS

• Analyzes the winding relationship inside a transformer

• Optimal for winding movement assessment after transport, high magnitude faults and lightning strikes

• Simple hookup and automated testing

• Results management software for establishment of baseline data and trending

• Available with a preconfigured laptop

Doble M5400Sweep Frequency Response Analyzer

Doble M5400

• State-of-the-art measurement of moisture content, tan delta and oil conductivity using dielectric frequency response

• Dedicated test procedures for power transformers, bushings and current transformers

• Reliable measurements even in high-interference environments

• Interfaces to high voltage amplifiers

• Easy-to-use software with automated measurement flow and analysis of test results

Megger IDAX300Insulation Diagnostic Analyzer

Megger IDAX300

• Tests the mechanical and electrical integrity of power transformers after transportation or exposure to high fault currents

• Measures the electrical transfer function over a wide range of frequencies

• Improves transformer reliability, reduces maintenance costs and prevents expensive failures

• Applications include transformer testing after:

y A short-circuit event

y Before and after transport

y An occurrence of high transient fault currents

y A significant change in the monitored values (for example, combustible gases) or a safety shutdown

Omicron FRANEO 800Sweep Frequency Response Analyzer

Omicron FRANEO 800

113(866) 352-5550 | protecequip.com

TRANSFORMER TEST & DIAGNOSTICS | SWEEP FREQUENCY RESPONSE ANALYZERS

S w e e p Fr e q u e n c y R e s p o n s e A n a l y z e r s

• Highest dynamic range and accuracy in the industry

• Fulfills international standards for SFRA measurements

• Wireless communication

• Battery operated

• Continuity control of ground connections

• Detects problems such as:

y Winding deformations and displacements

y Shorted turns and open windings

y Broken clamping structures

y Core connection problems

y Partial winding collapse

y Faulty core grounds

y Core movements

Megger FRAX101Sweep Frequency Response Analyzer

Megger FRAX101

114 (866) 352-5550 | protecequip.com

Tu r n s R a t i o Te s t S e t s

TRANSFORMER TEST & DIAGNOSTICS | TURNS RATIO TEST SETS

AEMC DTR8510

• Ideal for testing PTs, CTs (ratio and polarity) and some power transformers

• Displays turns ratio, winding polarity, excitation current and deviation from nameplate data

• Warns of incorrect lead connections, reverse polarity and open/short circuits

• DC test mode eliminates errors resulting from magnetic build up

• Records up to 10,000 results which can be downloaded to dataview software for trending and reporting

AEMC DTR8510Digital Transformer Ratiometer

• Combines TTR and resistance testing in one box

• Only one set of leads is required

• Unique Kelvin clamps with patented adjustable jaws each open to 100mm (4") as well as banana plug input for connection to terminal blocks

• Built-in demagnetization

Megger MWA330AThree-Phase Transformer Turns Ratio and Winding Resistance Analyzer

Megger MWA330A

• Optimized for three-phase power and distribution transformer measurements

• Combines winding resistance measurement, turns ratio, dynamic resistance measurement, core demagnetization, transformer type detection, magnetic balance, short circuit impedance and heat run test

• Simple “one-time-connection” system reduces measuring time

• Built-in simultaneous winding magnetization method guarantees fast and reliable resistance measurements

• Stable measurements are reached even on large power transformers with delta windings on the low voltage side

Haefely 2293 Automatic Transformer Winding Analyzer

Haefely 2293

Raytech T-RexThree-Phase Voltage Extension to Turns Ratio Meter

115(866) 352-5550 | protecequip.com

• Stand-alone or remote-control operation

• Accurately measures ratio, phase deviation and excitation current

• Field upgradeable without compromise to calibration

• Works in the presence of high interference/high voltage

• Highest ratio measurement (45,000:1); highest accuracy (0.1%)

Megger TTR310Three-Phase Transformer Turns Ratio Test Set

Megger TTR310

Tu r n s R a t i o Te s t S e t s

TRANSFORMER TEST & DIAGNOSTICS | TURNS RATIO TEST SETS

Omicron TESTRANO 600

• Tests include: y TTR y Exciting current y DC winding resistance y Dynamic resistance y Vector group check y Cool down test y Short-circuit impedance/leakage reactance y Frequency response of stray losses y Demagnetization y Power/dissipation factor (with CP TD12) y Quick test

• Powerful device with 3 x 33A DC or 400VAC

• Reduced wiring effort as same wiring can be used for different tests

• Automatic tap changer control and measurement

Omicron TESTRANO 600Three-Phase Power Transformer Test System

Raytech T-Rex

• Fully automatic with seamless integration to Raytech TR-Mark II

• Measure phase relationships of transformer windings while applying three-phase voltage

• Especially useful when measuring ratio of zig-zag type transformers

Raytech TR-1/TR-1PSingle-Phase Transformer Turns Ratio Meter

116 (866) 352-5550 | protecequip.com

Tu r n s R a t i o Te s t S e t s

TRANSFORMER TEST & DIAGNOSTICS | TURNS RATIO TEST SETS

Raytech TR-Mark III

• Simplified and convenient touchscreen user interface for test setup, results display and documentation storage

• Automatic measurements of voltage, turns ratio, current and phase displacement

• Automatic phase vector detection and includes percent error vs. nameplate data for secondary and tertiary windings

• On-board or computer based user configured transformer test plans and graphical tap changer display

• Optional Raytech T-Rex automates testing by measuring phase relationships of transformer windings while applying three-phase voltage

Raytech TR-Mark IIIThree-Phase Transformer Turns Ratio Meter

Vanguard ATRT-01/01B

• Displays turns ratio, winding polarity, excitation current and deviation from nameplate data

• Measures turns ratios from 0.8 to 15,000:1

• Output voltage of 4V or 40V (user selectable)

• Operates from faceplate with simple controls or automated testing through Vanguard’s TTRA S2 transformer analysis software

Vanguard ATRT-01/01B Single-Phase Transformer Turns Ratio Meter

Raytech TR-1/TR-1P

• Lightweight and battery operated (7 lbs)

• Measures transformer, PT or CT ratio and polarity

• Raytech TR-1P includes on-board printer

• Internal storage of 50 test results

• Ratio measurement from 0.8 to 4,000 turns

117(866) 352-5550 | protecequip.com

Tu r n s R a t i o Te s t S e t s

TRANSFORMER TEST & DIAGNOSTICS | TURNS RATIO TEST SETS

Vanguard ATRT-03A S2

• Measures turns-ratio, excitation current and phase angle readings

• Built-in transformer detection automatically identifies 130 different transformer configurations

• Measures ratios from 0.8 to 15,000:1

• Stores up to 128 transformer test plans in memory

• Stores up to 112 sets of test results in on-board memory

• Simplified data transfer through USB flash drive

Vanguard ATRT-03A S2Three-Phase Transformer Turns Ratio Meter

• Measures a transformer’s turns-ratio, excitation current, and winding phase angle

• Three test voltages (4Vac, 40Vac, 100Vac) allow the TRF-100 to test CT’s and PT’s

• Highest ratio measurement (50,000:1)

• Phase angle measurement (0 to 360°)

• To ensure accuracy, the TRF-100’s measuring circuitry self-calibrates before each measurement

Vanguard TRF-100Three-Phase Transformer Turns Ratio Meter

Vanguard TRF100

Vanguard TRF-250A

• Determines the turns-ratio of the transformer under test using the IEEE C57.12.90 measurement method

• Turns-ratio range is from 0.8 to 50,000:1

• Transformer turns ratio, excitation current, and winding polarity are displayed on the built-in 128 x 64 pixels graphic LCD screen

• Can be used as a standalone unit or can be computer-controlled

• The battery offers approximately three hours of continuous use

Vanguard TRF-250AThree-Phase Transformer Turns Ratio Meter

118 (866) 352-5550 | protecequip.com

TRANSFORMER TEST & DIAGNOSTICS | TURNS RATIO TEST SETS

Vanguard TRI-PHASE

• Generates true three-phase excitation test voltage so any transformer type can be measured, including exotic winding configurations

• Ideal for use on phase shifting winding configurations

• Measures turns-ratio, excitation current and phase angle readings

• Built-in transformer detection automatically identifies 130 different transformer configurations

• Measures ratios from 0.8 to 15,000:1

• Simplified data transfer through USB flash drive

Vanguard TRI-PHASETrue Three-Phase Transformer Turns Ratio Meter

Tu r n s R a t i o Te s t S e t s

119(866) 352-5550 | protecequip.com

W i n d i n g R e s i s t a n c e Te s t S e t s

TRANSFORMER TEST & DIAGNOSTICS | WINDING RESISTANCE TEST SETS

• Combines TTR and resistance testing in one box

• Only one set of leads is required

• Unique Kelvin clamps with patented adjustable jaws each open to 100mm (4") as well as banana plug input for connection to terminal blocks

• Portability, reduced set-up time and increased job safety

• Built-in demagnetization

• One test form — easier and faster to complete

Megger MWA330AThree-Phase Transformer Turns Ratio and Winding Resistance Analyzer

Megger MWA330A

Raytech WR14

• 15A output for testing most transformers with repeatable readings

• Automatically demagnetizes winding upon test completion

• Two measurement channels and on-board printer convenience

• Bright touchscreen interface or full computer control

• Color coded connections and simple interface for fast familiarization

• Automatic discharge circuit

Raytech WR14Winding Resistance Meter with Demagnetization and Discharge

• Optimized for three-phase power and distribution transformer measurements

• Combines winding resistance measurement, turns ratio, dynamic resistance measurement, core demagnetization, transformer type detection, magnetic balance, short circuit impedance and heat run test

• Simple “one-time-connection” system reduces measuring time

• Built-in simultaneous winding magnetization method guarantees fast and reliable resistance measurements

• Stable measurements are reached even on large power transformers with delta windings on the low voltage side

Haefely 2293 Automatic Transformer Winding Analyzer

Haefely 2293

120 (866) 352-5550 | protecequip.com

TRANSFORMER TEST & DIAGNOSTICS | WINDING RESISTANCE TEST SETS

W i n d i n g R e s i s t a n c e Te s t S e t s

Raytech WR50-12

• 50A output for testing the largest transformers with repeatable readings

• Automatically demagnetizes winding upon test completion

• Two measurement channels and on-board printer convenience

• Color-coded connections and simple interface for fast familiarization

• Automatic discharge circuit

• Optional Heat Run Test Software and three RTD inputs

Raytech WR50-12Winding Resistance Meter with Demagnetization and Discharge

Vanguard LTCA-40

• Controls tap changer from the front panel

• Measures winding resistance of highly inductive power transformers

• Measures and graphs LTC motor current with dynamic resistance measurements

• Calculates equivalent resistance values with user’s input of apparatus temperature

• Outputs 40A with a 60V DC source

• Automatic discharge to ensure operator safety

• Measures from 1μΩ to 500Ω

Vanguard LTCA-40Load Tap Changer Analyzer

Vanguard TRM-403

• Connects to all three-phases (one winding) simultaneously: one test for the primary, one test for the secondary

• Provides individual Delta or Wye (with no neutral) winding resistance values

• Ideal for measuring winding resistance of transformers, motors or generators and other inductive devices

• Automatic demagnetization of winding

• Automatic discharge upon completing the test

• Make-before-break mode provides a dynamic resistance graph of the load tap changer

Vanguard TRM-403Transformer Resistance Meter

121(866) 352-5550 | protecequip.com

TRANSFORMER TEST & DIAGNOSTICS | WINDING RESISTANCE TEST SETS

Vanguard WRM-10

• Single channel winding resistance test set

• Automatic current from 10mA to 10A

• Digital resistance reading from 1μΩ to 2,000Ωs

• Dual input channels measure two winding resistances simultaneously

Vanguard WRM-10Winding Resistance Test Set

W i n d i n g R e s i s t a n c e Te s t S e t s

122 (866) 352-5550 | protecequip.com

123(866) 352-5550 | protecequip.com

INDEX

IndexAABB 504 .............................................................................................Secondary Current Injection Test Set .............................................................................................65ABB 505 .............................................................................................Secondary Current Injection Test Set .............................................................................................65ABB 606 .............................................................................................Secondary Current Injection Test Set .............................................................................................65ABB 607 .............................................................................................Secondary Current Injection Test Set .............................................................................................65ABB BTSB ..........................................................................................Secondary Current Injection Test Set .............................................................................................65ABB CB-2000 ...................................................................................Portable Capacitance Meter ...................................................................................................... 35, 72ABB Ekip ............................................................................................Secondary Current Injection Test Set .............................................................................................65ABB PR010/T ...................................................................................Secondary Current Injection Test Set .............................................................................................65AEMC 275HVD ...............................................................................Non-Contact Voltage Detector .........................................................................................................23AEMC 3711/3731 ..........................................................................Clamp On Ground Resistance Test Set ...........................................................................................29AEMC 6240/6250 ..........................................................................10A Micro-Ohmmeter .................................................................................................................. 38, 53AEMC 6416 ......................................................................................Clamp On Ground Resistance Tester ..............................................................................................29AEMC 6536 ......................................................................................Insulation Resistance Test Sets .........................................................................................................63AEMC BR07 ......................................................................................Decade Box ................................................................................................................................................73AEMC DTR8510 .............................................................................Digital Transformer Ratiometer .....................................................................................................114AEMC PEL 103 ................................................................................Power and Energy Logger ....................................................................................................................92AEMC PEL 105 ................................................................................Power and Energy Logger ....................................................................................................................92Alber Cellcorder CRT-400 ..........................................................Cell Resistance Tester ............................................................................................................................. 3Alber Cellcorder CRT-400 ..........................................................Cell Resistance Tester ............................................................................................................................. 2Alber DMA-35-CR .........................................................................Hydrometer with Data Logging ........................................................................................................... 2Allen-Bradley140G-ELTT ............................................................Secondary Current Injection Test Set .............................................................................................65Ametek CTC-650A .........................................................................Dry Block Calibrators ............................................................................................................................75Amprobe ACD-15 TRMS-PRO ..................................................Multifunction Multimeter ...................................................................................................................81Amprobe AT-3000 ..........................................................................Underground Cable Locator ................................................................................................................. 7Amprobe AT-7030 ..........................................................................Advanced Wire Tracer Kit ..................................................................................................................... 8Amprobe DM-5 ...............................................................................Power Quality Analyzer .......................................................................................................................92Aqua-Tronics EG 3000/EG 3000 T ..........................................Secondary Cable Fault Locator ........................................................................................................... 8Aqua-Tronics S.D.A.D. ...................................................................Acoustic Fault Detector ......................................................................................................................... 8Arbiter 928A ....................................................................................Multifunction Multimeter ...................................................................................................................81Arbiter 930A ....................................................................................Power Analyzer ........................................................................................................................................93Astro-Med (AstroNova) TMX-18 .............................................18-Channel Data Acquisition System .............................................................................................91

BBattery Ground Fault ............................................................................................................................................................................................................................................... 1Battery Hydrometers ............................................................................................................................................................................................................................................... 2Battery Impedance .................................................................................................................................................................................................................................................... 3Battery Load Units ..................................................................................................................................................................................................................................................... 4Battery Test Equipment ........................................................................................................................................................................................................................................... 1Battery Voltage Monitors ....................................................................................................................................................................................................................................... 5Bender LT3000 ................................................................................Line Isolation Monitor ................................................................................................................... 23, 30B&K Precision 885 .........................................................................LCR/ESR Meter ................................................................................................................................ 35, 72Borescopes..................................................................................................................................................................................................................................................................71

CCable & Bus Test Equipment .................................................................................................................................................................................................................................. 7Cable Fault Locating Test Sets ...............................................................................................................................................................................................7, 8, 9, 10, 11, 12Capacitance & Inductance Meters ....................................................................................................................................................................................................................72Capacitance & Inductance Test Sets .................................................................................................................................................................................................................35Carriere STS100 .............................................................................Secondary Current Injection Test Set .............................................................................................65Circuit Breaker Timing Test Sets ................................................................................................................................................................................................................ 36, 37Communications Analyzers .................................................................................................................................................................................................................................99Cooper Power Systems Eaton DC Nova ...............................Adaptor .......................................................................................................................................................50Cooper Power Systems Eaton KMET1 MET .......................Recloser Controller Tester ..................................................................................................................50Cooper Power Systems Eaton KMET45811 .......................Triple / Single Adaptor...........................................................................................................................50Cooper Power Systems Eaton ...................................................VFI VFI Tester ...........................................................................................................................................50COSA Xentaur XPDM ...................................................................Portable Dew Point Meter ..................................................................................................................74Current Transformer (CT) Test Sets ...............................................................................................................................................................................................................105

124 (866) 352-5550 | protecequip.com

DData Acquisition .......................................................................................................................................................................................................................................................91Decade Boxes .............................................................................................................................................................................................................................................................73DENT ELITEpro ...............................................................................Power Datalogger ...................................................................................................................................91Dew Point & Humidity Analyzers ......................................................................................................................................................................................................................74Digital Low Resistance Ohmmeters .............................................................................................................................................................38, 39, 40, 41, 53, 54, 55, 56DILO 3-027-R002 ..........................................................................SF6 Volume Percentage (Purity) Analyzer....................................................................................25DILO 3-033-R002 ..........................................................................LeakPointer SF6 Leak Detector ........................................................................................................25DILO 3-033-R200 ..........................................................................LeakSpy SF6 Leak Detector ................................................................................................................26DILO 3-038-R032 NP ...................................................................SF6 and CF4 Analyzer ...........................................................................................................................26DILO 3-038R-R303 .......................................................................SF6 Analyzer with Recirculation .......................................................................................................26DILO SF6 Analyzer .........................................................................Adapter Kit Regulator, Fitting and Adaptor Kit for SF6 Analysis .........................26, 27, 28DILO SF6 HB 120A ........................................................................Cylinder Heating Blanket .....................................................................................................................27Doble 9084UC .................................................................................Transducer Test Set ................................................................................................................................51Doble F2253 .....................................................................................Single-Phase Relay Test Set .............................................................................................................100Doble F6051 .....................................................................................Time Synchronizer for F6150 .........................................................................................................101Doble F6071 .....................................................................................Infrared Optical Pickup for F6150 ................................................................................................101Doble F6150sv ................................................................................Compatible Accessories ....................................................................................................................101Doble F6150sv ................................................................................Power System Simulator with GOOSE ........................................................................................101Doble F6300e ..................................................................................External Amplifier ......................................................................................................................101, 102Doble F6895 .....................................................................................GPS Module for F6150 ......................................................................................................................101Doble M4000/M4100 ..................................................................Power Factor Test Set ................................................................................................................ 47, 109Doble M4110 ...................................................................................Leakage Reactance Module ..................................................................................................... 47, 109Doble M4140 ...................................................................................Capacitor Bank Test Kit ............................................................................................................. 47, 109Doble M5400 ...................................................................................Sweep Frequency Response Analyzer .........................................................................................112Doble OTC .........................................................................................Oil Test Cell .............................................................................................................................................108Doble RTS7 .......................................................................................Key for F6150 ........................................................................................................................................101Doble TDR9100/TDR900 ...........................................................Circuit Breaker Test System ...............................................................................................................36Doble TR3171 .................................................................................Motion/Travel Transducer ...................................................................................................................51Doble TR3186 .................................................................................Transducer Test Set ................................................................................................................................51Doble TR3189 .................................................................................Transducer Test Set ................................................................................................................................51Doble TR3190 .................................................................................Transducer Test Set ................................................................................................................................51Doble TRMLP50 .............................................................................Transducer Test Set ................................................................................................................................51Doble Type C ....................................................................................Resonating Inductor ................................................................................................................... 47, 109Dranetz Dranflex6K36 .................................................................Current Probe ..........................................................................................................................................93Dranetz Dranflex6K ......................................................................Current Probe ..........................................................................................................................................93Dranetz Dranflex 36 ......................................................................Current Probe ..........................................................................................................................................93Dranetz Dranflex 48 ......................................................................Current Probe ..........................................................................................................................................93Dranetz Dranflex 348 ...................................................................Current Probe ..........................................................................................................................................93Dranetz Dranflex (Green) ...........................................................Current Probe ..........................................................................................................................................93Dranetz Dranflex HD3 .................................................................Current Probe ..........................................................................................................................................93Dranetz Dranflex HD ....................................................................Current Probe ..........................................................................................................................................93Dranetz Dranflex (Red) ................................................................Current Probe ..........................................................................................................................................93Dranetz HDPQ Xplorer/PowerExplorer PX5 Compatible Current Probes .....................................................................................................................................93Dranetz HDPQ Xplorer ................................................................Power Quality Analyzer .......................................................................................................................93Dranetz PowerExplorer PX5 .....................................................Power Monitor .........................................................................................................................................93Dranetz PR150SP1 ........................................................................Current Probe ..........................................................................................................................................93Dranetz PR1500SP ........................................................................Current Probe ..........................................................................................................................................93Dranetz TR2510 .............................................................................Current Probe ..........................................................................................................................................93Dry Block Calibrators .............................................................................................................................................................................................................................................75

EEA Technology CableData Collector ......................................Partial Discharge Analyzer .......................................................................................................... 18, 88EA Technology UltraTEV Plus2 .................................................Multifunction Partial Discharge Analyzer ............................................................................ 18, 88Eaton Cutler-Hammer 70C1056G54 ....................................Secondary Current Injection Test Set .............................................................................................65Eaton Cutler-Hammer 70C1056 .............................................Secondary Current Injection Test Set .............................................................................................65Eaton Cutler-Hammer 140D481G03. ...................................Secondary Current Injection Test Set .............................................................................................65Eaton Cutler-Hammer 1232C50G05 ....................................Secondary Current Injection Test Set .............................................................................................65Eaton Cutler-Hammer 1232C50G10 (STK2) .....................Secondary Current Injection Test Set .............................................................................................65Eaton Cutler-Hammer 1287C56G02 ....................................Secondary Current Injection Test Set .............................................................................................65Eaton Cutler-Hammer 7801C57 .............................................Secondary Current Injection Test Set .............................................................................................65Eaton Cutler-Hammer 8779C02G03 ....................................Secondary Current Injection Test Set .............................................................................................65Eaton Cutler-Hammer MTK1000 ............................................Secondary Current Injection Test Set .............................................................................................65Eaton Cutler-Hammer MTK2000 ............................................Secondary Current Injection Test Set .............................................................................................65

INDEX

125(866) 352-5550 | protecequip.com

INDEX

Eaton Cutler-Hammer PRTAAPM ...........................................Secondary Current Injection Test Set .............................................................................................66Electrical Safety ................................................................................................................................................................................................................................................ 23, 24Electrical Test Instruments ETI ACDC-10 ............................AC and DC Power Supply.....................................................................................................................82Electrical Test Instruments ETI-AD-1/AD-2 ........................AC and DC Power Supply.....................................................................................................................82Electrical Test Instruments ETI PI-1600B ............................16,000A High Current Test Set .........................................................................................................57Electrical Test Instruments ETI PI-5000/PI-6000 ............40,000A/60,000A High Current Test Set......................................................................................58Emerson 475/475FB .....................................................................Multifunction Multimeter ...................................................................................................................81ETI PI-800 ..........................................................................................Primary Current Injection Test Set ..................................................................................................64ETI PI-1600B Duty Cycles ....................................................................................................................................................................................................................................57ETI PI-1600B ....................................................................................Primary Current Injection Test Set ..................................................................................................64ETI PI-5000 Duty Cycles .......................................................................................................................................................................................................................................58ETI PI-5000 .......................................................................................Primary Current Injection Test Set ..................................................................................................64ETI PI-6000 Duty Cycles .......................................................................................................................................................................................................................................58ETI PI-6000 .......................................................................................Primary Current Injection Test Set ..................................................................................................64Extech HDV640 HD ......................................................................VideoScope Articulating Probe .........................................................................................................71

FFederal Pioneer DDT-USRC .......................................................Secondary Current Injection Test Set .............................................................................................66FLIR C2 ...............................................................................................Compact Thermal Camera ..................................................................................................................76FLIR T440 ..........................................................................................Thermal Imaging Camera .....................................................................................................................76FLIR T530 ..........................................................................................Professional Thermal Camera ...........................................................................................................76FLIR T640 ..........................................................................................Thermal Imaging Camera .....................................................................................................................77Fluke 43B ...........................................................................................Single-Phase Power Quality Analyzer .................................................................................... 81, 94Fluke 87V ...........................................................................................Multifunction Multimeter ...................................................................................................................81Fluke 190-204/S .............................................................................Multifunction Multimeter ...................................................................................................................81Fluke 192 ...........................................................................................Multifunction Multimeter ...................................................................................................................81Fluke 434/435 .................................................................................Compatible Current Probe .................................................................................................................94Fluke 434/435 .................................................................................Three-Phase Power Quality and Energy Analyzer ....................................................................94Fluke 435 ...........................................................................................Multifunction Multimeter ...................................................................................................................81Fluke 754 ...........................................................................................Multifunction Multimeter ...................................................................................................................81Fluke 787 ...........................................................................................Multifunction Multimeter ...................................................................................................................81Fluke 810 ...........................................................................................Multifunction Multimeter ...................................................................................................................81Fluke 1587 FC ..................................................................................Insulation Multimeter ................................................................................................................... 63, 81Fluke 1587MDTFC ........................................................................Insulation Resistance Test Sets .........................................................................................................63Fluke 1625 ........................................................................................Multifunction Geo Earth Ground Test System ............................................................................30Fluke 1735 ........................................................................................Three-Phase Power Quality Logger ................................................................................................95Fluke 1736 ........................................................................................Three-Phase Power Quality Logger ................................................................................................95Fluke 1750 ........................................................................................Compatible Current Probes ...............................................................................................................96Fluke 1750 ........................................................................................Three-Phase Power Quality Logger ................................................................................................96Fluke 3035A3 ...................................................................................Current Probe ..........................................................................................................................................93Fluke 3035A .....................................................................................Current Probe ..........................................................................................................................................93Fluke 3140R .....................................................................................Current Probe ..........................................................................................................................................96Fluke 3310 ........................................................................................Current Probe ..........................................................................................................................................96Fluke 9040 ........................................................................................Phase Rotation Indicator .....................................................................................................................78Fluke i5s .............................................................................................Current Probe ..........................................................................................................................................94Fluke i5sPQ3 ....................................................................................Current Probe ..........................................................................................................................................94Fluke I5SPR .......................................................................................Current Probe ..........................................................................................................................................96Fluke i30s ...........................................................................................Current Probe ..........................................................................................................................................94Fluke i200s ........................................................................................Current Probe ..........................................................................................................................................94Fluke i400s ........................................................................................Current Probe ..........................................................................................................................................94Fluke i600s ........................................................................................Current Probe ..........................................................................................................................................94Fluke Networks OptiFiber Pro Series 2 ................................Optical Time Domain Reflectometer (OTDR) ............................................................................... 9Fluke PMM-1 ...................................................................................Multifunction Multimeter ...................................................................................................................81Fluke Ti55 ..........................................................................................Thermal Imager ........................................................................................................................................77Fluke Ti450 .......................................................................................SF6 Gas Detector ....................................................................................................................................27Fuji FLD22 .........................................................................................Transducer Test Set ................................................................................................................................51

GGas & SF6 Analysis ........................................................................................................................................................................................................................... 25, 26, 27, 28GE DEH-233 .....................................................................................Secondary Current Injection Test Set .............................................................................................66GE GTUTK20 ...................................................................................Secondary Current Injection Test Set .............................................................................................66General Resistance DA-RTD-200 ............................................Decade Box ................................................................................................................................................73GE PST1-1 .........................................................................................Secondary Current Injection Test Set .............................................................................................66GE TAKTS2 ........................................................................................Secondary Current Injection Test Set .............................................................................................66

126 (866) 352-5550 | protecequip.com

INDEX

GE TTS1 ..............................................................................................Secondary Current Injection Test Set .............................................................................................66GE TVRMS2 ......................................................................................Secondary Current Injection Test Set .............................................................................................66GE TVTS1 ...........................................................................................Secondary Current Injection Test Set .............................................................................................66Ground Cluster ................................................................................Available in Multiple Configuration .................................................................................................24Ground Resistivity ..................................................................................................................................................................................................................... 29, 30, 31, 32, 33

HHaefely 2293 ....................................................................................Automatic Transformer Winding Analyzer .....................................................................114, 119Hart Scientific 9100S-A ...............................................................Dry Block Calibrators ............................................................................................................................75Hart Scientific 9100S ....................................................................Dry Block Calibrators ............................................................................................................................75Hart Scientific 9103-A ..................................................................Dry Block Calibrators ............................................................................................................................75Hart Scientific 9140-A ..................................................................Dry Block Calibrators ............................................................................................................................75Hart Scientific 9141-A ..................................................................Dry Block Calibrators ............................................................................................................................75High Current Test Sets ......................................................................................................................................................................................................57, 58, 59, 60, 61, 62High Voltage ALT-120/60 ............................................................60kV and 120kV Power Frequency AC Hipot ..................................................................... 13, 42High Voltage Circuit Breaker & Substation ...................................................................................................................................................................................................35High Voltage DTS-60A .................................................................Oil Dielectric AC Test Set ..................................................................................................................108High Voltage DTS-100D ..............................................................Oil Dielectric AC Test Set ..................................................................................................................108High Voltage PFT-301CM ...........................................................30kV Power Frequency AC Hipot ............................................................................................ 13, 42High Voltage PFT-303 ..................................................................30kV Power Frequency AC Hipot ............................................................................................ 13, 42High Voltage PFT-303/PFT-503CM .......................................30kV and 50kV AC Hipot .....................................................................................................................59High Voltage PFT-503CM ...........................................................50kV Power Frequency AC Hipot ............................................................................................ 14, 43High Voltage PFT-652CM 6 ........................................................5kV Power Frequency AC Hipot ........................................................................................14, 43, 59High Voltage PTS-75/PTS-80 ....................................................75kV and 80kV DC High Voltage Test Set and Megohmmeter .................................... 14, 43High Voltage PTS-130 ..................................................................130kV DC Hipot and Megohmmeter ...................................................................................... 15, 44High Voltage PTS-200 ..................................................................200kV DC Hipot and Megohmmeter ...................................................................................... 15, 44High Voltage Tan Delta Measurement Systems ...........................................................................................................................................................................................21High Voltage TD-34E ....................................................................Tan Delta Bridge ......................................................................................................................................21High Voltage TDR1669 ................................................................Time Domain Reflectometer ................................................................................................................ 9High Voltage VLF-34E/VLF-65E ..............................................34kV/65kV VLF Hipot ................................................................................................................... 16, 45High Voltage VLF-4022CM ........................................................40kV High Load Capacity Portable VLF Hipot .................................................................... 15, 44Hioki PW3196/PW3198 .............................................................Power Quality Analyzer .......................................................................................................................97Hipotential Test Sets ............................................................................................................................................................................ 13, 14, 15, 16, 17, 42, 43, 44, 45, 46HT Instruments I-V400w ............................................................Curve Tracer ..............................................................................................................................................84HV Diagnostics BA-75 ..................................................................Portable Breakdown Analyzer for Oil Testing ..........................................................................108HV Diagnostics EZ-Cable ID ......................................................Single/Three-Phase Cable and Phasing Identification System ............................................... 9HV Diagnostics High Voltage Sources for Off-Line PD Analysis .................................................................................................................................................. 20, 87HV Diagnostics HVA28TD ..........................................................VLF/DC High Voltage Test Set ................................................................................................... 17, 46HV Diagnostics HVA30 ................................................................VLF/DC High Voltage Test Set ................................................................................................... 17, 46HV Diagnostics HVA34TD ..........................................................VLF/DC High Voltage Test Set .................................................................................... 17, 20, 46, 87HV Diagnostics HVA34 ................................................................. VLF/DC High Voltage Test Set .................................................................................................. 17, 46HV Diagnostics HVA45TD ..........................................................VLF/DC High Voltage Test Set ................................................................................................... 17, 46HV Diagnostics HVA60 ................................................................VLF/DC High Voltage Test Set .................................................................................... 17, 20, 46, 87HV Diagnostics HVA90 ................................................................VLF/DC High Voltage Test Set .................................................................................... 17, 20, 46, 87HV Diagnostics HVA120 .............................................................VLF/DC High Voltage Test Set .................................................................................... 17, 20, 46, 87HV Diagnostics HVA High Voltage Test Sets .................................................................................................................................................................................................46HV Diagnostics HVA VLF/DC High Voltage Test Sets ...............................................................................................................................................................................17HV Diagnostics PDTD60 .............................................................Partial Discharge and Tan Delta System ................................................................................ 20, 87HV Diagnostics PDTD60/PDTD120 ......................................60kV and 120kV Partial Discharge and Tan Delta System ............................................. 16, 45HV Diagnostics PDTD120 ..........................................................Partial Discharge and Tan Delta System ................................................................................ 20, 87HV Diagnostics Tan Delta Measurement Systems .....................................................................................................................................................................................21HV Diagnostics TD30 ...................................................................Tan Delta Bridge ......................................................................................................................................21HV Diagnostics TD60-MC ..........................................................Tan Delta Test System ...........................................................................................................................21HV Diagnostics TD60 ...................................................................Tan Delta Bridge ......................................................................................................................................21HV Diagnostics TD90-MC ..........................................................Tan Delta Measurement System .......................................................................................................21

IInfrared Survey .................................................................................................................................................................................................................................................. 76, 77Insulation Resistance Test Sets ...........................................................................................................................................................................................................................63Iris Power ELCID .............................................................................Electromagnetic Core Imperfection Detection Test Set .........................................................78Iris Power SWA ................................................................................Stator Wedge Analyzer ........................................................................................................................78IUP Fault Wizard ............................................................................Cable Fault Locator ................................................................................................................................10

127(866) 352-5550 | protecequip.com

INDEX

LLarkin Power M3K .........................................................................Semiconductor Tester ...........................................................................................................................79Low/Medium Voltage Circuit Breakers & Switchgear ...............................................................................................................................................................................53

MMadTest DSM4i1 ............................................................................Secondary Current Injection Test Set .............................................................................................66Manta MTS-5100 ...........................................................................Protective Relay Test System ..........................................................................................................102Megger 210415 ..............................................................................Insulation Resistance Test Sets .........................................................................................................63Megger 230425 ..............................................................................4kV AC and 5kV DC Hipot ..................................................................................................................59Megger 560400 ..............................................................................Phase Rotation Tester ...........................................................................................................................79Megger BGFT ...................................................................................Battery Ground Fault Tracer ................................................................................................................ 1Megger BGL ......................................................................................Battery Ground Fault Locator.............................................................................................................. 1Megger BITE2P ...............................................................................Battery Impedance Test Set .................................................................................................................. 3Megger BITE3 ..................................................................................Battery Impedance Test Set .................................................................................................................. 3Megger BM15R ...............................................................................Insulation Resistance Test Sets .........................................................................................................63Megger BVM-300/600 ................................................................Battery Voltage Monitor ....................................................................................................................4, 5Megger CB100 ................................................................................Power Factor Test Set ................................................................................................................ 48, 110Megger CB-832 ...............................................................................1,800A High Current Test Set .................................................................................................... 60, 64Megger CB-845 ...............................................................................4,500A High Current Test Set .................................................................................................... 60, 64Megger CFL535G ...........................................................................Advanced Dual Channel TDR .............................................................................................................10Megger DDA-1600 ........................................................................16,000A Circuit Breaker Test Set ............................................................................................. 60, 64Megger DDA-6000 ........................................................................60,000A Universal Circuit Breaker Test Set ........................................................................ 61, 64Megger DELTA4310 ......................................................................Power Factor Test Set ................................................................................................................ 48, 110Megger DET2/2 ..............................................................................Digital Ground Resistance Tester .....................................................................................................30Megger DET3TC/ICLAMP ..........................................................3 Terminal Ground Resistance Tester .............................................................................................31Megger DET4TCR2 4 ..................................................................... Terminal Ground Resistance Tester ................................................................................................31Megger DET24C .............................................................................Ground Resistance Clamp Tester .....................................................................................................31Megger DET62D .............................................................................Digital Earth Tester ................................................................................................................................32Megger DLRO10HD .....................................................................10A Digital Low Resistance Ohmmeter (DLRO) .........................................................38, 53, 54Megger DLRO200-115 ................................................................200A Digital Low Resistance Ohmmeter (DLRO) .............................................................. 39, 54Megger DLRO600 ..........................................................................600A Digital Low Resistance Ohmmeter (DLRO) .............................................................. 39, 54Megger FRAX101 ...........................................................................Sweep Frequency Response Analyzer .........................................................................................113Megger ICLAMP .............................................................................AC Current Probe ...................................................................................................................................31Megger IDAX300 I ..........................................................................nsulation Diagnostic Analyzer ........................................................................................................112Megger L1050 .................................................................................Portable Cable Fault Locator .............................................................................................................10Megger MIT485 ..............................................................................Insulation Resistance Test Sets .........................................................................................................63Megger MIT520 ..............................................................................Insulation Resistance Test Sets .........................................................................................................63Megger MIT525 ..............................................................................Insulation Resistance Meter ............................................................................................. 48, 63, 110Megger MIT1025 ...........................................................................Insulation Resistance Test Sets .........................................................................................................63Megger MIT1525 ............................................................................ Insulation Resistance Test Sets.........................................................................................................63Megger MOM2 ................................................................................200A Digital Low Resistance Ohmmeter (DLRO) .............................................................. 39, 55Megger MRCT .................................................................................Relay and Current Transformer Tester........................................................................................105Megger MS-2A ................................................................................500A Circuit Breaker and Overcurrent Relay Test Set.................................................... 61, 64Megger MWA330A .......................................................................Three-Phase Transformer Turns Ratio and Winding Resistance Analyzer .........114, 119Megger ODEN AT ...........................................................................21,900A Primary Current Injection Test System ............................................................... 61, 64Megger OTS-60PB .........................................................................60kV Oil Dielectric Test Set .............................................................................................................108Megger PFL22M1500 ..................................................................Portable Cable Fault Location System ...........................................................................................11Megger PFL40A ..............................................................................Portable Cable Fault Location System ...........................................................................................11Megger S1554 .................................................................................Insulation Resistance Test Sets .........................................................................................................63Megger SG32-1500M ..................................................................Portable Fault Location System ........................................................................................................11Megger SMRT36 .............................................................................Relay Test System ................................................................................................................................102Megger SMRT46 .............................................................................Multi-Phase Relay Test System ......................................................................................................103Megger SMRT410 ..........................................................................Relay Test System ................................................................................................................................103Megger SPI225 ................................................................................Smart Primary Injection Test System ..............................................................................................64Megger TORKEL 860 ....................................................................Battery Load Unit ..................................................................................................................................4, 5Megger TORKEL 950 ....................................................................Battery Load Unit ...................................................................................................................................... 4Megger TTR310 ..............................................................................Three-Phase Transformer Turns Ratio Test Set .......................................................................115Merlin Gerin 55391 or ME .........................................................Secondary Current Injection Test Set .............................................................................................66Meters & Instrumentation ....................................................................................................................................................................................................................................71Metrel 3103 ......................................................................................Insulation Resistance Test Sets .........................................................................................................63Metrel 3200 ......................................................................................Insulation Resistance Test Sets .........................................................................................................63Mikron 7200V .................................................................................Infrared Camera ......................................................................................................................................77Motor & Semiconductor Analyzers ....................................................................................................................................................................................................78, 79, 80Multifunction Multimeters ...................................................................................................................................................................................................................................81

128 (866) 352-5550 | protecequip.com

OOfil Systems DayCor Superb-OD ............................................Corona Camera ................................................................................................................................ 18, 88Oil Test Equipment ...............................................................................................................................................................................................................................................108Olympus IPLEX RT .........................................................................Videoscope ................................................................................................................................................71Omicron ARCO 400 ......................................................................Universal Test Set for Recloser Controls .......................................................................................50Omicron CB TN3 ............................................................................Transducer Node for CIBANO 500 .......................................................................................... 36, 51Omicron CIBANO 500 .................................................................3-in-1 Circuit Breaker Test System ..................................................................................................36Omicron CMC 356 .........................................................................Universal Relay Test Set and Commissioning Tool .................................................................103Omicron CP B2 ................................................................................Accessory to CPC 100 for Current Requirements Up to 2000A .............................. 49, 111Omicron CPC 100 ..........................................................................Multifunctional Primary Test System ........................................................................... 33, 49, 111Omicron CP CU1 ............................................................................Multifunctional Coupling Unit for CPC 100 .................................................................................32Omicron CP SB1 .............................................................................Switch Box for Automated Transformer Testing .....................................................................111Omicron CP TD1 ............................................................................Capacitance/Dissipation Factor Testing Device ............................................................. 49, 111Omicron CP TD12 ..........................................................................Capacitance and Power/Dissipation Factor ..........................................33, 49, 106, 111, 115Omicron CT Analyzer ...................................................................Current Transformer Testing, Calibration and Assessment ...............................................106Omicron FRANEO 800 ................................................................Sweep Frequency Response Analyzer .........................................................................................112Omicron RCP1 .................................................................................(19 Pin) Recloser Control Cable .....................................................................................................103Omicron Recloser Control Cable Packages ................................................................................................................................................................................................103Omicron RST1 .................................................................................(14 Pin) Recloser Control Cable .....................................................................................................103Omicron RVT1 .................................................................................(32 Pin) Recloser Control Cable .....................................................................................................103Omicron TESTRANO 600 ...........................................................Three-Phase Power Transformer Test System ....................................................... 33, 106, 115

PPartial Discharge ......................................................................................................................................................................................................................................................87Partial Discharge (Off-Line) Test Sets ...................................................................................................................................................................................................... 20, 87Partial Discharge (On-Line) Test Sets ................................................................................................................................................................................. 18, 19, 20, 88, 89PdMA MCEMAX .............................................................................Motor Circuit Evaluation Analyzer ..................................................................................................80PdMA MCE .......................................................................................Motor Circuit Evaluator .......................................................................................................................79Phenix 6CP100/50-10 .................................................................50kV & 100kV AC Dielectric Test Set ..................................................................................... 16, 45Photovoltaic Monitoring .......................................................................................................................................................................................................................................84PMDT PDetector ............................................................................Handheld Partial Discharge Detector .................................................................................... 19, 89PowerComm PCA-4125 ..............................................................Power Communications Analyzer ....................................................................................................99Power Factor Test Sets............................................................................................................................................................................................. 47, 48, 49, 109, 110, 111Power Quality ............................................................................................................................................................................................................................................................91Power Quality Analyzers..................................................................................................................................................................................................92, 93, 94, 95, 96, 97Power Supplies .................................................................................................................................................................................................................................................. 82, 83Primary Current Injection Test Sets .................................................................................................................................................................................................................64

RRadian Research RB-10 ...............................................................Bantam Lite Portable Test Kit ............................................................................................................85Raytech CT-T1 ..................................................................................Current Transformer Tester ............................................................................................................106Raytech Micro Centurion II MC-2 ...........................................200A Micro Ohm Meter ............................................................................................................... 40, 55Raytech Micro Junior 2 ................................................................10A Micro Ohm Meter ................................................................................................................. 40, 55Raytech TR-1/TR-1P .....................................................................Single-Phase Transformer Turns Ratio Meter ..........................................................................116Raytech T-Rex ..................................................................................Three-Phase Voltage Extension to Turns Ratio Meter .........................................................115Raytech TR-Mark III ......................................................................Three-Phase Transformer Turns Ratio Meter ..........................................................................116Raytech WR14 .................................................................................Winding Resistance Meter with Demagnetization and Discharge ..................................119Raytech WR50-12 .........................................................................Winding Resistance Meter with Demagnetization and Discharge ..................................120Recloser Control Test Sets....................................................................................................................................................................................................................................50Relay & Protection ...................................................................................................................................................................................................................................................99RH Systems 973- .............................................................................SF6 Gas Analyzer ....................................................................................................................................28RKI GX-2009 ....................................................................................Gas Detector .............................................................................................................................................24

SSatin American ETC-PTS .............................................................Secondary Current Injection Test Set .............................................................................................66Scientific Columbus SC10 ...........................................................Watthour Standard Meter ..................................................................................................................85Seaward PV150 ...............................................................................Solar Installation Tester ........................................................................................................................84Seaward Solar Utility Pro ............................................................Complete Solar Kit .................................................................................................................................84Secondary Current Injection Test Sets .............................................................................................................................................................................................65, 66, 67Siemens ELTPHB ............................................................................Secondary Current Injection Test Set .............................................................................................66Siemens PTS-3 .................................................................................Secondary Current Injection Test Set .............................................................................................66Siemens PTS-4 .................................................................................Secondary Current Injection Test Set .............................................................................................66

INDEX

129(866) 352-5550 | protecequip.com

Siemens PTS-5 .................................................................................Secondary Current Injection Test Set .............................................................................................66Siemens SBAPM ..............................................................................Secondary Current Injection Test Set .............................................................................................66Siemens TD500 ...............................................................................Secondary Injection Test Set ..............................................................................................................66Siemens TS-31 .................................................................................Secondary Current Injection Test Set .............................................................................................66Siemens Westrip Adapter ............................................................ Secondary Current Injection Test Set ............................................................................................67Siemens WLTS .................................................................................Secondary Current Injection Test Set .............................................................................................67Simran SIM-3000 ...........................................................................Step Up/Down Voltage Transformer ...............................................................................................82Single-Phase Test Sets .........................................................................................................................................................................................................................................100SKF Baker AWA-IV/12 .................................................................Static Motor Analyzer ...........................................................................................................................80SKF Baker PP30 ..............................................................................Power Pack ................................................................................................................................................80SMC Raptor C-05 ...........................................................................3,800A Multifunctional Primary Testing System ............................................................... 62, 64Solar Monitoring .......................................................................................................................................................................................................................................................84Sonel UV-260 ...................................................................................Corona Camera ................................................................................................................................ 20, 89Square D CBTM1 ............................................................................Secondary Current Injection Test Set .............................................................................................67Square D CBTM3 ............................................................................Secondary Current Injection Test Set .............................................................................................67Square D CBTM4A ........................................................................Secondary Current Injection Test Set .............................................................................................67Square D CBTMB ...........................................................................Secondary Current Injection Test Set .............................................................................................67Square D S33595 ............................................................................Secondary Current Injection Test Set .............................................................................................67Square D UTA Tester .....................................................................Secondary Current Injection Test Set .............................................................................................67Square D UTS-3 ...............................................................................Secondary Current Injection Test Set .............................................................................................67Staco 1520-3/C-3 ...........................................................................Variable Transformer .............................................................................................................................83Storage Battery Systems SBS-2003 .......................................Battery Hydrometer/Density Meter ................................................................................................ 2Storage Battery Systems SBS-3500 .......................................Battery Hydrometer/Density Meter ................................................................................................ 2Storage Battery Systems SBS-8400 .......................................Battery Capacity Tester .......................................................................................................................... 4Summit Technology PowerSight PS3550 .............................Power Analyzer ........................................................................................................................................96Sweep Frequency Response Analyzers ..............................................................................................................................................................................................112, 113

TTan Delta Test Sets ...................................................................................................................................................................................................................................................21Three-Phase Test Sets .....................................................................................................................................................................................................................101, 102, 103Time Electronics 1051 ..................................................................Resistance Decade Box .........................................................................................................................73Transducer Test Sets ...............................................................................................................................................................................................................................................51Transformer Test & Diagnostics ......................................................................................................................................................................................................................105Turns Ratio Test Sets ................................................................................................................................................................................................... 114, 115, 116, 117, 118

UUtility Relay Company B-290 ....................................................Secondary Current Injection Test Set .............................................................................................67Utility Relay Company B-291MP .............................................Secondary Current Injection Test Set .............................................................................................67Utility Relay Company B-292 .....................................................Secondary Current Injection Test Set .............................................................................................67

VVacuum Bottle Test Sets ................................................................................................................................................................................................................................ 68, 69Vacuum Interrupters CBT-1202 ..............................................Circuit Breaker Timer ............................................................................................................................68Vacuum Interrupters MAC TS4 ................................................Vacuum Interrupter Tester .................................................................................................................68Vacuum Interrupters PowerVac V1 ........................................Rigid Magnetic Coil for GE PowerVac Circuit Breakers ..........................................................68Vaisala DM70 ...................................................................................Dew Point Analyzer ...............................................................................................................................74Vanguard ATRT-01/01B ..............................................................Single-Phase Transformer Turns Ratio Meter ..........................................................................116Vanguard ATRT-03A S2 ...............................................................Three-Phase Transformer Turns Ratio Meter ..........................................................................117Vanguard Auto-Ohm 100 ............................................................100A Micro-Ohmmeter ............................................................................................................... 40, 56Vanguard Auto-Ohm 200 S3 .....................................................200A Micro-Ohmmeter ............................................................................................................... 41, 56Vanguard CT-6500 .........................................................................Circuit Breaker Timer Analyzer ........................................................................................................36Vanguard CT-7000 S3/S6 ............................................................Circuit Breaker Timer and Travel Analyzer ..................................................................................37Vanguard CT-8000 S3 ...................................................................Circuit Breaker Timer Analyzer ........................................................................................................37Vanguard DigiTMR ........................................................................Circuit Breaker Timer and Analyzer ................................................................................................69Vanguard EZCT-2000A ................................................................Automated CT Test Set ......................................................................................................................107Vanguard EZCT-2000C Plus ......................................................Automated CT Test Set ......................................................................................................................107Vanguard EZCT/EZCT-10 ...........................................................CT Test Set ..............................................................................................................................................107Vanguard LTCA-40 .........................................................................Load Tap Changer Analyzer .............................................................................................................120Vanguard MCCB-250 ...................................................................500A Circuit Breaker Test Set ................................................................................................... 62, 64Vanguard RT-1 .................................................................................Transducer Test Set ................................................................................................................................51Vanguard RT-2 .................................................................................Transducer Test Set ................................................................................................................................51Vanguard TR1 Ext ..........................................................................Transducer Test Set ................................................................................................................................51Vanguard TR-1 .................................................................................Transducer Test Set ................................................................................................................................51

INDEX

130 (866) 352-5550 | protecequip.com

INDEX

Vanguard TR-2 .................................................................................Transducer Test Set ................................................................................................................................51Vanguard TRF-100 ........................................................................Three-Phase Transformer Turns Ratio Meter ..........................................................................117Vanguard TRF-250A .....................................................................Three-Phase Transformer Turns Ratio Meter ..........................................................................117Vanguard TR-HMB ........................................................................Transducer Test Set ................................................................................................................................51Vanguard TRI-PHASE ...................................................................True Three-Phase Transformer Turns Ratio Meter ................................................................118Vanguard TRM-403 .......................................................................Transformer Resistance Meter .......................................................................................................120Vanguard UPS-S2 ...........................................................................Universal Power Supply........................................................................................................................83Vanguard VBT-60 ...........................................................................60kV Vacuum Bottle Tester ................................................................................................................69Vanguard WRM-10 ........................................................................Winding Resistance Test Set............................................................................................................121VON XF28-1960 .............................................................................Portable Arc Reflection Combination TDR Thumper ..............................................................12

WWatthour Meters .....................................................................................................................................................................................................................................................85Westinghouse 12552C48G02 ..................................................Secondary Current Injection Test Set .............................................................................................67Westinghouse SPBPTK (1272C61G02) ...............................Secondary Current Injection Test Set .............................................................................................67Wika GA10 ........................................................................................SF6 Gas Analyzer ....................................................................................................................................28Winding Resistance Test Sets .......................................................................................................................................................................................................119, 120, 121

The Megger Baker MTR105 is a dedicated static motor tester. Its multifunction capabilities include:

n Insulation tester

nDigital low resistance ohmmeter (DLRO)

n Voltmeter

nMotor rotation tester

n LCR meter

nTemperature measurement

Some of the key features include:

n Guard terminal

n Full graphic color display

n Three-phase connection

n IP54 environmental protection

n Operating altitude up to 3000 m

n Temperature compensation for IR

Keep your motors healthy…

… In the palm of your hand

Megger Baker MTR105 Testing your electric motors is essential in determining their condition. Performing a suite of test types helps to build up a clearer picture in maintaining and preventing failure.

So get a clean bill of health for your motors by using the Megger MTR105.

protecequip.com(866) 352-5550

D a l l a s1517 W Carrier Pkwy, Ste 116

Grand Prairie, Texas 75050(972) 352-5550

C h i c a g o1501 Wright Blvd

Schaumburg, Illinois 60193(847) 434-5808

A t l a n t a880 Veterans Memorial Hwy, SE

Mableton, Georgia 30126(678) 210-1423

N e w Yo r k70 Triangle Blvd

Carlstadt, New Jersey 07072(201) 450-9743

H o u s t o n14251 Gulfstream Park Dr

Webster, Texas 77598(832) 251-7047

R e n o -Ta h o e924 Greg St

Sparks, Nevada 89431(775) 984-5223

Lo s A n g e l e s2935 E Ricker Way

Anaheim, California 92806(657) 758-5098

D e nve r12050 E 45th Ave, Unit 400

Denver, Colorado 80239(720) 826-6378

Pro

tec Eq

uip

men

t Reso

urces T

he E

lectrical Test & M

easurem

ent E

qu

ipm

ent R

ental E

xperts

2

02

1