43
instruments Analytical Instruments for Science ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE

ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

instruments

i

Analyt icalInstrumentsfor Sc ience

ELEMENTALSPECTROSCOPY

PRODUCT BROCHURE

AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2

Page 2: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

ContentsPAGE NO.

Introduction 5

Detection Limits 7

AA500 Atomic Absorption Spectrometer 8

AAWin3 Software – NOW GLP Compliant 12

AA990F Atomic Absorption Spectrometer 18

AAWin2 Software 20

Atomic Absorption Spectrometer Qualification Kit 24

Atomic Fluorescence Spectroscopy 26

AF402 Simultaneous Atomic Fluorescence Spectrometer 28

PFWin Software 31

FP902 Flame Photometer 34

Consumables 38

3

Analyt icalInstrumentsfor Sc ience

AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 4

Page 3: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

4

AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 5

Page 4: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

AAS is an analytical procedure for the Qualitative and

Quantitative determination of chemical elements in a

sample. The technique is based on the Lambert-beer

principle which states that the absorbance of a solution

(A) is directly proportional to its path length (I) and its

concentration (C) when the wavelength of incidence

light remains fixed. This is summarized in the following

equation, where (ε) is the molar absorbtivity.

A= εIc

PG Instruments offer a range of instrumentation

designed to meet the requirements of all industry

sectors including Agricultural, Clinical, Environmental,

Food, Metal, Mining and Materials, Petrochemical

and Pharmaceutical. Further information about the

technique and products can be found in this brochure.

AAS Principle

Atomic Absorption Spectrophotometers (AAS) have

become an industry standard for many elemental

determinations within specific industries. There are

three AAS techniques including Flame, Graphite

Furnace, and Hydride Generation, all of which have

their own advantages and disadvantages due to

analytical limitations. The flame technique, being the

most common, will determine trace levels (usually ppm)

for most analytical elements and it is also the most cost

effective technique. If determinations of lower levels

are required (usually ppb) the graphite technique can

be used. There are a number of elements that form

volatile hydrides and these can be analysed using the

hydride technique.

Atomic Absorption Analysis

A hollow cathode lamp containing a coated cathode of

the element that is to be analysed is used as a light

source. The light source emits a beam of a specific

wavelength through the flame and into the

monochromator. The sample is aspirated into the flame

in the form of an aerosol which is converted to an

atomic vapour, atoms present in the vapour are then

raised from their ground state to their excited state. The

atoms absorb light of a specific wavelength when

moving to an excited energy state, this causes the

quantity of light absorbed to increase. The light

absorption then can be measured and used for a

Quantitative determination of the amount of analyte in

a sample.

Atomic Emission Analysis

For the determination of certain elements, usually those

excited at high wavelengths, a variation of the standard

flame technique can be performed which is called

atomic emission. As the technique relies on the spectral

emission from the flame there is no requirement for the

hollow cathode lamp. The sample is aspirated into the

flame which causes the ground state atoms to convert

to an excited state. As the excited state is very unstable

the atoms return to their ground state and emit an

emission spectrum consisting of a number of emission

wavelengths. The intensity of an emission line will

therefore increase as the number of excited atoms of

the specific element increases. The specific wavelength

of the emission can be used for a Quantitative

analysis to determine the concentration of a element in

a solution.

Instrumentation

The Atomic Absorption Spectrometer is made up of five

essential components. Each component is designed to

produce minimum disruption to the overall system and

many design features are installed to keep the signal to

noise ratio as low as possible.

l Light Source

l Burner Assembly

l Optics

l Detector

l Signal Processing

Since its development in the 1950’s the Atomic Absorption Spectrometer(AAS) has evolved into an accurate and reliable analytical tool usedextensively in today’s modern laboratory.

5

Atomic Absorption Spectroscopy

AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 6

Page 5: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

Techniques

There are three main techniques for AAS analysis each

having their strengths and weaknesses depending on

the type of analysis required. There are a number of

factors to consider when deciding which technique will

suit the application. For example:

l Detection limits l Working range

l Speed of analysis l Automation

l Sample volume l Sample matrix

l Equipment cost l Precision of results

l Element suitability l Available space required

l Clean area l Method development

l Running costs

Flame Analysis

Flame AAS is the standard technique used for general

purpose analysis. The readings are normally accepted to

be trace levels of ppm and nearly all elements can be

analysed to this level. There is a choice of Air/Acetylene

flame used for easily ionised elements and Nitrous

Oxide/Acetylene flame for the less easily excited

elements. The flame technique requires a number of

extra components to complete the installation.

l Oil free Air Compressor

l Ultra pure Acetylene Gas

l Nitrous Oxide Gas (optional)

l Natural Gas/LPG (optional)

l Autosampler (optional)

l Suitable Fume Extraction System

Graphite Analysis

The graphite analysis technique uses an assembly

containing a graphite tube to replace the burner. This

technique is used to analyse very low levels with low

sample volumes. Although the detection limit is very low,

the precision is almost always higher than that of the

flame technique. The graphite technique requires a

number of extra components to complete the installation.

l Water Circulating System for Cooling.

l Pure Argon Gas.

l High Current Power Supply

l Autosampler (optional)

l Suitable Fume Extraction System

Hydride Analysis

The hydride technique requires an additional unit to

add to the flame AAS system. The Hydride Generator is

used to produce a hydride vapour, for the hydride

forming elements, by means of a heated tube which fits

directly to the top of the flame burner. The unit can also

be used for cold vapour technique primarily for Mercury

analysis. The hydride technique requires the following

extra components to complete the installation.

l Pure Argon gas

l Suitable fume extraction system

6

1H

2He

3Li

11Na

19K

37Rb

55Cs

87Fr

4Be

12Mg

5B

13Al

20Ca

38Sr

56Ba

88Ra

21Sc

39Y

22Ti

40Zr

72Hf

104Rf

23V

41Nb

73Ta

105Db

24Cr

42Mo

74W

106Sg

25Mn

43Tc

75Re

107Bh

25Mn

43Tc

75Re

107Bh

25Mn

43Tc

75Re

107Bh

25Mn

43Tc

75Re

107Bh

25Mn

43Tc

75Re

107Bh

25Mn

43Tc

75Re

107Bh

25Mn

43Tc

75Re

107Bh

25Mn

43Tc

75Re

107Bh

25Mn

43Tc

75Re

107Bh

26Fe

44Ru

76Os

108Hs

26Fe

44Ru

76Os

108Hs

26Fe

44Ru

76Os

108Hs

26Fe

44Ru

76Os

108Hs

26Fe

44Ru

76Os

108Hs

26Fe

44Ru

76Os

108Hs

26Fe

44Ru

76Os

108Hs

26Fe

44Ru

76Os

108Hs

26Fe

44Ru

76Os

108Hs

26Fe

44Ru

76Os

108Hs

27Co

45Rh

77Ir

109Mt

28Ni

46Pd

78Pt

110Ds

29Cu

47Ag

79Au

111Rg

30Zn

48Cd

80Hg

112UUb

31Ga

49In

81Tl

113Uut

6C

14Si

32Ge

50Sn

82Pb

114Uuq

7N

15P

33As

51Sb

83Bi

115Uup

8O

16S

34Se

52Te

84Po

116Uuh

9F

17Cl

35Br

53I

85At

117Uus

10Ne

18Ar

36Kr

54Xe

86Rn

118Uuo

57La

89Ac

58Ce

90Th

59Pr

91Pa

75Re

107Bh

75Re

107Bh

75Re

107Bh

75Re

107Bh

75Re

107Bh

75Re

107Bh

75Re

107Bh

75Re

107Bh

76Os

108Hs

76Os

108Hs

76Os

108Hs

76Os

108Hs

76Os

108Hs

76Os

108Hs

76Os

108Hs

76Os

108Hs

76Os

108Hs

60Nd

92U

61Pm

93Np

62Sm

94Pu

63Eu

95Am

64Gd

96Cm

65Tb

97Bk

66Dy

98Cf

67Ho

99Es

68Er

100Fm

69Tm

101Md

70Yb

102No

71Lu

103Lr

Lanthanides

Actinides

GroupPeriod

1

2

3

4

5

6

7

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

Elements – Periodic Table

AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 7

Page 6: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

Detection limitsElement Wavelength Air/C2H2 N2O/C2H2/C2H2 Air/LPG Graphite Vapour

(nm) mg/l(ppm) mg/l(ppm) mg/l(ppm) µg/l(ppb) µg/l(ppb)

Aluminium (Al) 309.3 n/a 0.028 n/a 0.13 n/a

Antimony (Sb) 217.6 0.092 n/a 0.21 0.29 0.26

Arsenic (As) 193.7 0.12 n/a n/a 0.33 0.05

Barium (Ba) 553.6 n/a 0.031 n/a 0.23 n/a

Beryllium (Be) 234.9 n/a 0.0036 n/a 0.02 n/a

Bismuth (Bi) 223.1 0.0049 n/a 0.03 0.26 0.19

Boron (B) 249.7 n/a 3.5 n/a n/a n/a

Cadmium (Cd) 228.8 0.0028 n/a 0.008 0.01 n/a

Calcium (Ca) 422.7 n/a 0.0037 0.07 0.60 n/a

Chromium (Cr) 357.9 0.0054 n/a 0.6 0.025 n/a

Cobalt (Co) 240.7 0.01 n/a 0.018 2.00 n/a

Copper (Cu) 324.8 0.0045 n/a 0.0026 0.065 n/a

Dysprosium (Dy) 421.7 n/a 0.2 n/a n/a n/a

Europium (Eu) 459.4 n/a 0.04 n/a n/a n/a

Gold (Au) 242.8 0.013 n/a 0.026 3.00 n/a

Indium (In) 303.9 0.07 n/a 0.04 n/a n/a

Iron (Fe) 248.3 0.0043 n/a 0.015 0.06 n/a

Lead (Pb) 217.0 0.013 n/a 0.02 0.03 n/a

Lead (Pb) 283.3 0.016 n/a 0.04 0.08 n/a

Lithium (Li) 670.8 0.0021 n/a 0.004 0.70 n/a

Magnesium (Mn) 285.2 0.0022 n/a 0.002 0.09 n/a

Manganese (Mn) 279.5 0.0016 n/a 0.0019 0.03 n/a

Mercury (Hg) 253.7 n/a n/a n/a 40.0 0.15

Molybdenum(Mo) 313.3 n/a 0.021 n/a 0.14 n/a

Nickel (Ni) 232.0 0.008 n/a 0.012 0.065 n/a

Palladium (Pd) 247.6 0.03 n/a 0.018 0.04 n/a

Phosphorus (P) 213.6 n/a 10.0 n/a n/a n/a

Platinum (Pt) 265.9 0.12 n/a 0.22 0.04 n/a

Potassium (K) 766.5 0.0009 n/a 0.0041 0.40 n/a

Rhodium (Rh) 343.5 0.009 n/a 0.037 0.02 n/a

Rubidium (Rb) 780.0 0.003 n/a 0.005 n/a n/a

Scandium (Sc) 391.2 n/a 0.02 n/a n/a n/a

Selenium (Se) 196.0 0.23 n/a n/a 0.32 0.27

Silicon (Si) 251.6 n/a 0.30 n/a 17.0 n/a

Silver (Ag) 328.1 0.0032 n/a 0.0023 0.04 n/a

Sodium (Na) 589.0 0.0037 n/a 0.0086 n/a n/a

Strontium (Sr) 460.7 n/a 0.005 n/a 0.01 n/a

Tantalum (Ta) 271.5 n/a 2.2 n/a n/a n/a

Tellurium (Te) 214.3 0.054 n/a n/a 3.20 0.43

Thallium (Tl) 276.8 0.014 n/a n/a 0.015 n/a

Tin (Sn) 224.6 n/a 0.21 n/a 15.0 1.39

Titanium (Ti) 365.4 n/a 0.05 n/a 0.5 n/a

Tungsten (W) 255.1 n/a 1.2 n/a n/a n/a

Vanadium (V) 318.5 n/a 0.11 n/a 0.03 n/a

Zinc (Zn) 213.9 0.0033 n/a 0.0037 0.08 n/a

7

AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 8

Page 7: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

8

ATOM IC A B SOR P T I ON S P EC T ROMET E R

AA500

AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 9

Page 8: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

The AA500 Atomic Absorption Spectrometer is

a high performance automated instrument

designed to meet the requirements of the

modern laboratory. Due to its versatility and

performance it can be used for a wide range of

applications including:

l Agricultural l Clinical

l Environmental l Food

l Metal l Mining

l Geological l Petrochemical

l Pharmaceutical

The versatile instrument is available in threeconfigurations:

AA500F – The instrument is equipped with a flame

atomiser only. The positioning of which is fully controlled by

the embedded computer system and AA Win software.

Three flame options are available to the user with the

Air/Acetylene being the standard configuration. This

flame can be used for nearly all standard elements while

the N2O/Acetylene and the Air/LPG (Natural gas) are

available as an option for the more demanding of

elements. All three flame configurations offer coded

burner for full safety protection.

AA500G – The instrument is equipped with a Graphite

Furnace Atomiser only. The graphite head is fixed into the

optical path to maximise performance and eliminate drift.

The temperature of the transversely heated graphite tube

is accurately controlled by means of a precision feedback

system. Pyrolytically coated platform tubes are supplied

as standard to improve the performance and eliminate

many analytical problems associated with this technique.

AA500FG – The instrument is equipped with both Flame

Atomiser and Graphite Atomiser as described above. Both

configurations are installed into the instrument and can

be changed over by a simple selection in the versatile

AA Win software.

9

NEWUPGRADE

AVAILABLE

Full Automation for

multi-elem

ent analysis

NOW GLP COMPLIANT

AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 10

Page 9: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

F EATURES & FUNCT IONS

l Embedded PC system built into the instrument as

standard on all configurations. Pre-installed AAWin3

software, user manuals, cook book and Windows

operating system.

l AAWin3 software provides full control of the

instrument and autosampler with easy method

change for each technique. Now GLP compliant.

l Automatic 8 Hollow Cathode lamp turret controlled

and optimised by the AAWin3 software. Operating

lamp current and warm-up lamp current can be

individually controlled to eliminate drift commonly

associated with lamp warming.

l D2 lamp background correction system fitted as

standard to all configurations. High energy D2 lamp

and adjustable beam splitter mirror are optimised by

the AAWin3 software.

l Self Reversal background correction system fitted as

standard to all configurations. The high performance

background system uses the same hollow cathode

lamp as installed for the analysis. Minimum extra

components are required and optical alignment is

very simple. Self Reversal can be used for any element

at any wavelength making it extremely versatile.

l High precision minimal optics ensures maximum light

throughput to the computer controlled Czerny-

Turner monochromator.

l A universal autosampler is available as an optional

accessory which is conveniently mounted on the

front of the AA500 instrument.

l Optional XYZ autosampler provides appropriate

sample volume for multi element analysis, along with

scalable sample capacity for high sample throughput.

l Absorption and Emission modes are standard features

in the AAWin3 software as well as peak height, peak

area, sequential and manual integration modes.

F LAME ATOM I S ER F EATURES

The flame atomiser offers three flame options:

Air/acetylene is the standard configuration with the

N2O/acetylene and Air/LPG as options.

Air/Acetylenel The Air/Acetylene flame uses a 100mm single slot

burner for the standard configuration.

l The high sensitivity (Cu 2ppm >0.280abs) is due to

the inert adjustable nebuliser fitted as standard.

An acid resistant replacement is available with a

Pt/Ir capillary.

l The flame can be easily set from blue lean flame

through stoichiometric to fuel rich by means of

computer control.

N20/Acetylenel The N2O/Acetylene flame uses a 50mm single slot

burner and is available as an optional extra.

l This flame configuration is used to measure elements

less prone to ionization such as: Aluminium, Tin,

Titanium, Calcium, Vanadium and Molybdenum.

l Switching from Air/Acetylene to N2O/Acetylene to

Flame Off is fully controlled by the AAWinPro

software.

Air/Propane (LPG)l This flame uses a 3 slot burner and with the low

pressure requirement it is also much safer to operate.

l Due to the low temperature of the flame it is ideal for

analysing alkali metals such as: Potassium, Sodium and

Lithium, especially when used in the emission mode.

l Some remote areas of the world have difficulty

obtaining Acetylene gas of a high enough purity to

operate the flame correctly, LPG can give a real

alternative and offer comparable results for most

elements throughout the wavelength range.

10

AA500continued

AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 11

Page 10: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

11

Safety Featuresl Pressure monitoring for all gases

l Burner Identification

l Flame sensor

l Drain Trap level Sensor

l Gas Leak Detector

l Over Pressure in Premix

l Safety Cut off Switch

GRAPH I T E ATOM I S ER F EATURES

The integrated Graphite Furnace Atomiser is available

in two instrument configurations.

l In the AA500G instrument the graphite furnace head

is fixed into the light path so alignment with the

optical path is simple and accurate.

l In the AA500FG instrument the graphite furnace

head is fixed behind the flame atomiser assembly and

is motorised into position by a simple operation in

the AAWinPro software. The positions for the flame

and graphite are saved making it easy to swap

between modes for different analysis.

l The temperature of the transversely heated graphite

tube is accurately controlled by means of a precision

feedback system and has been designed to reduce

analytical problems normally associated with this

type of technique.

l Pyrolytically coated graphite tubes are used as standard

and are manufactured to improve performance as well

as increase the analytical life.

l Platform graphite tubes are supplied as standard and

will accept volumes up to 20µl. Non-platform

graphite tubes are also available as an optional extra.

l Up to 10 heat stages are available for the programming

of the graphite atomiser. These can be set and stored

within the AAWinPro software.

l The graphite tube is held in position by means of a gas

piston. Replacement of the graphite tube is performed

by a simple command in the AAWin Software.

l The graphite tube is efficiently cooled by an additional

water circulation system (supplied separately).

Safety Featuresl Argon Gas pressure Sensor

l Water flow sensor

l Over Temperature Sensor

l Broken graphite tube protection

AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 12

Page 11: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

12

AAWin3Software

The AAWin3 software allows the Analyst to control all

aspects of their analytical method whilst providing an

extensive range of tools for data collection, storage

and interpretation.

The software interface consists of three key work-

areas, whilst having toolbars to access many others.

These work areas allow the user to view real-time

signal acquisition, up-to-date display of calibration

curves and a flexible, sample table.

The AAWin3 software offers full automation allowing

the user to measure multiple elements sequentially by

means of a Sample Wizard and optional random access

autosampler.

AAWin3 Software is a powerful and intuitive software product designed toallow control and data acquisition from the PG Instruments AA500 seriesAtomic Absorption Spectrometer.

Lamp turret setup, operating and warm-up currents,

along with the desired analytical wavelength are

easily selected in the configuration.

AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 13

Page 12: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

Full Automation for Multi-Element Analysis

13For more details and ordering information please visit our website www.pginstruments.com

Ensure optimal peak position at the chosen analytical

line by scanning the emissions spectra.

Each stage of analysis setup is made quick and simple

by means of the Sample Wizard.

Obtain reliable and accurate results by using the

Energy control feature to manually optimise atomiser

position and setup.

Use the Auto-balance feature to ensure energy level,

and optical alignments are optimised when using

background correction.

Use the sample table to perform quick measurements

of both Standards and Samples.

Easily append the sample table to add new samples or

even revise calibration curves either by manual

introduction or using an Autosampler.

View up-to-date calibration curves in 1st, 2nd, or 3rd

order using a standard calibration or standard

addition.

Perform retrospective curve fits to ensure optimum

correlation.

View real-time signal acquisition for flame, graphite

furnace and hydride generation analysis.

NOWGLPCOM

PLIANT

AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 14

Page 13: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

14

SpecificationsSpectrometer System

Wavelength range 185nm - 910nm

Light Source Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

Modulation Square Wave Pulse

Modulation frequency 100hz Self reversal (SR) background, 400hz Deuterium Arc (D2) background

Monochromator

Grating 1800 grooves/mm diffraction grating

Blazed Wavelength 250nm

Focus 300nm

Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm (Software selectable)

Scan mode Automatic

Photometric Type Single Beam

Wavelength Accuracy +/-0.15nm

Wavelength Resolution 0.2nm +/-0.02nm

Wavelength Reproducibility < 0.05nm

Baseline Stability 0.005Abs/30min

Background Correction Deuterium Arc (D2) 1.0Abs, Self Reversal (SR) 3.0Abs

Flame Analysis

Flame Types Air/Acetylene, Nitrous Oxide/Acetylene, Air/Propane (LPG)

Sensitivity (Cu) 2µg/ml Absorption >0.280Abs

Characteristic Concentration Cu < 0.02µg/ml, Ba < 0.15µg/ml ( N2O/Acetylene)

Detection Limit Cu < 0.004µg/ml

Repeatability Cu < 0.7% (Air/Acetylene Flame)Ba < 1.0% (Nitrous Oxide/Acetylene Flame)

Burner heads Titanium Alloy

Nebuliser Inert Adjustable Nebuliser, Flow Rate from 2ml - 6ml/min. Pt/Ir capillary available for high acid concentration

Pre-mix Chamber Corrosion Resistant

Atomiser Selection Automatic changeover (AA500FG), Manual (AA500F)

Safety Features Burner identification, Flame Sensor, Gas Leak Sensor, Low Gas Pressure Sensor,Drain Trap Sensor, Power Loss Protection

Graphite Furnace Analysis

Graphite Head Transversally Heated

Temperature Range Ambient – 2650C

Heating Program Up to 10 steps. Drying, Ashing, Atomisation, Cleaning

Feedback Voltage and Optical Temperature Control Feedback

Sensitivity (Cu) 50ng/ml Absorption > 0.40Abs

Detection Limit Cd < 0.004ng/ml

Repeatability Cu < 2.0%, Cd < 2.0%

Graphite Tubes Pyrolytically Coated with Platform

Sample Size Up to 20µl

Graphite Cooling Water Circulator Available

Safety Features Argon Pressure Sensor, Water Flow Sensor, Over Temperature Sensor, BrokenTube Protection

AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 15

Page 14: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

15

Specifications

Standard packaging

Spectrometer System

Data Processing

PC System Embedded PC, Windows Professional Operating System

Operating Program AA Win Pro software

Analytical Methods Flame AA, Flame AE, Graphite Furnace, Hydride Generation

Readout Mode Continuous, Manual, Peak Height, Peak Area

Calibrations Multi-Standard Calibration, Standard Addition, Interpolation

Data Storage Analytical results, instrument and measurement parameters, signal profile, calibration curve

Power Requirements

Main Unit 110/230Vac 50/60hz 200W

Graphite Power Supply 220Vac 50/60hz Instantaneous power 5KW Current rating??

Dimensions

Main unit 110cm x 54cm x 54cm 75Kg

Graphite Power Supply 50cm x 54cm x 54cm 70Kg

AA500F

1 Main unit

1 AA500F instruction Manual

1 Cook Book

1 Safety Manual

1 System validation document

1 Data coded Air/Acetylene burner

1 Inert adjustable Nebuliser

8 Hollow cathode Lamp Holders

1 Monitor

1 Keyboard and Mouse

1 Low Voltage power Supply

2 Power Cables

1 Gas tubing Air

1 Gas Tubing Acetylene

1 Drain Trap and Tubing

1 Tool Kit

1 Various gas Fittings

AA500G

1 Main unit

1 AA500G instruction Manual

1 Cook book

1 Safety Manual

1 System Validation document

8 Hollow cathode Lamp Holders

1 Monitor

1 Keyboard and Mouse

1 Low Voltage Power Supply

2 Power Cables

1 Tool Kit

1 Various Gas Fittings

10 Graphite Tubes

1 Gas Tubing Argon

1 Connection Cable (Graphite)

1 Pipette

1bag Pipette Tips

AA500FG

1 Main unit

1 AA500F instruction Manual

1 Cook Book

1 Safety Manual

1 System validation document

1 Data coded Air/Acetylene burner

1 Inert adjustable Nebuliser

8 Hollow cathode Lamp Holders

1 Monitor

1 Keyboard and Mouse

1 Low Voltage power Supply

2 Power Cables

1 Gas tubing Air

1 Gas Tubing Acetylene

1 Drain Trap and Tubing

1 Tool Kit

1 Various gas Fittings

10 Graphite tubes

1 Gas Tubing Argon

1 Connection Cable (graphite)

1 Pipette

1bag Pipette Tips

AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 16

Page 15: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

Accessories

Flame Analysisl 38 sample positions (6 for standard samples, 32 for unknown

samples).

l Sample vial size 6ml

l Standard sample vial size 12ml

l Pressure protection for wash

l Position adjustment by AA Win software

l Reproducibility Cu < 0.6% (air/acetylene) Cu< 1.0% (air/LPG)

Ba <1.0% (nitrous oxide/acetylene)

Graphite Analysisl 76 sample positions (10 for standard samples, 6 for modifier

solutions, 60 for unknown samples)

l Sample vial size 1.5ml

l Modifier vial size 12ml

l Pressure protection for wash

l Up to 3 modifier additions

l Position adjustments by AA-Win Pro software

l Reproducibility Cu <2.0%, Cd <2.0%

Autosampler (500-004)The AS500 Autosampler is an accessory specifically designed for the AA500 Atomic Absorption Spectrometer. The AS500 can be used to automatically introduce standard and unknown samples to the atomiser for analysis. It can be used with both flame and graphite furnace instruments.

Nitrous Oxide/Acetylene Burner (500-023)

l Titanium alloy

construction

l 50mm single slot

l Coded for safety

l Direct replacement for

standard burner

l Designed for higher

temperature flame

l Adjustment of burner

rotation for sensitivity

optimisation

Air/Propane (LPG) Burner (500-030) XYZ Autosampler

l Titanium Alloy

construction

l 3 slot burner

l Coded for safety

l Direct replacement for

standard burner

l Designed for lower

temperature flame

l Adjustment of burner

rotation for sensitivity

optimisation

Inert Adjustable Nebuliser (500-011)

l Excellent RSD’s typically<1.0%

l Typical read back valuesbetter than 2%

l Enhanced sensitivity

l Can be used on all PGInstruments AA500 andAA990 series atomicabsorption systems

l Redesigned spray chamberto ensure excellentdrainage properties

For more details and ordering information please visit our website www.pginstruments.com16

l High Sample Volume for

multi-element analysis

l Scalable Sample capacity

for high sample

throughput

l Acid resistant nebuliserwith Pt/Ir capillary(500-012)

l Adjustable uptake from 2-6ml/min

l Fully adjustable impactbead

Patent pending

AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 17

Page 16: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

Hydride Unit (500-007)

l Universal design

l Full reaction cycle from

press of start button

l Supplied with

temperature controlled

heated absorption cell

l Cell is easily installed with

burner attachment

l Can be used for Mercury

cold vapour analysis

l Sensitivity for most

elements <1ng/ml

l Only 2.0ml – 2.5ml per

sample required

l RSD < 3%

l Quick analysis < 30

seconds per measurement

Air Compressor (GS-003)

Fume Extraction System

l Ultra low noise whenrunning – just 53-59dB (A)

l 100% Oil Free Design

l Efficient, Horizontal Twinpump unit

l Innovative CompactDesign, perfect for limitedspace

l 10 bar Maximum pressure

l 15 Litre tank for stable airsupply

l 104L/min supply at 3 bar

l Easy to ship only 14Kg

Water Circulator (GS-005)

For use with AA500G /

AA500FG

l Re-circulating water

cooler

l 2Kw cooling capacity

l 230v, 270 watts power

(110v available, please

call for details.)

l Rust free 5 Litre Water

Capacity

l 2 Litre per minute

flow rate

l Forced air cooling system

l 2x Male quick connection

points 2x Female quick

fittings supplied

l Dimensions (LWH)

250 x 245 x 700 mm

l Tubing and additional

connectors optional

Gas Regulators (GS-001, GS-002, GS-006, GS-007)

l Direct fitting to

gas cylinder

l Comply to British

Standards

l Supplied with hose

fitting and crimp

l Various gas cylinder

fittings available

l Regulators for Air,

Acetylene, Argon, LPG

l Specify fitment to

European standard

Acetylene Flame Arrestor (GS-004)

l Direct fitting to gas

regulator output

l Required for acetylene gas

l Non-resetting easy

to replace

For more details and ordering information please visit our website www.pginstruments.com 17

l Universal fitting

l Stainless steelconstruction

l All fittings supplied

l 150mm polymer fan

l 240Vac 50/60hz

l 300mm diameter hood,adjustable height

l Adjustable bends from 0° to 90°

AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 18

Page 17: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

18

ATOM IC A B SOR P T I ON S P EC T ROMET E R

AA990F

The PG990 Atomic Absorption Spectrophotometer is

a versatile entry level instrument with a computer

controlled Air/Acetylene flame for general laboratory

requirements. Due to its high sensitivity and excellent

performance the instrument can be used for a wide

range of applications including:

l Agricultural

l Clinical

l Environmental

l Food

l Metal

l Mining

l Geological

l Petrochemical

l Pharmaceutical

AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 19

Page 18: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

F EATURES & FUNCT IONS

l The instrument has a motorised 8 hollow cathode

lamp turret which allows the automatic positioning

and optimisation of each hollow cathode lamp by

the software.

l The control of the gas flows for the fuel gas (C2H2) of

the burner is also carried out directly from the software

thus allowing optimisation of the instrument for the

best analytical parameters for a selected analysis.

l Two methods of background correction are available.

The first utilises a Deuterium Arc lamp and the second

is the proven method of Self Reversal.

l High precision minimal optics ensures maximum light

throughput to the computer controlled Czerny-Turner

Monochromator.

l The location of the wavelength and peak selection is

automatically controlled from the software.

l The spectral bandwidth is automated and is available

with a choice of five slit sizes.

l The electronic parameters for the photomultiplier tube

detector, the hollow cathode lamp current and the

balancing of the absorbance and background energies

are controlled from the software.

l The ignition of the flame is computer controlled

and the various safety interlocks offer a very safe

operating system.

SAFETY

l The flame conditions are continuously monitored and

should the flow rates change, an audible alarm sounds.

l The pressure of the support gas (oxidant) is monitored

constantly. If the pressure changes then the flow of

the fuel gas will be stopped and the flame will be

safely extinguished.

l A sensor monitors the level of liquid in the drain

and will prevent ignition if too low. The flame will also

be extinguished if the level of liquid in the drain

changes significantly.

l A flame sensor monitors the flame and safely turns off the

gas flow to the burner if the flame suddenly extinguishes.

l The burner is identified by a switch making it

impossible to light without the burner being fitted.

l An emergency flame off button is installed in case a

problem is observed. The flame can be extinguished

safely.

19

AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 20

Page 19: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

20

AAWin2Software

The AAWin2 software allows the Analyst to control all

aspects of their analytical method whilst providing an

extensive range of tools for data collection, storage

and interpretation.

The software interface consists of three key work-areas,

whilst having toolbars to access many others. These

work areas allow the user to view real-time signal

acquisition, up-to-date display of calibration curves and

a flexible, sample table.

AAWin2 Software is a powerful and intuitive software product designed toallow control and data acquisition from the PG Instruments PG990 AtomicAbsorption Spectrometer.

Lamp turret setup, operating and warm-up currents,

along with the desired analytical wavelength are easily

selected in the configuration.

AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 21

Page 20: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

21For more details and ordering information please visit our website www.pginstruments.com

Ensure optimal peak position at the chosen analytical

line by scanning the emissions spectra.

Each stage of analysis setup is made quick and simple

by means of the Sample Wizard.

Obtain reliable and accurate results by using the

Energy control feature to manually optimise atomiser

position and setup.

Use the Auto-balance feature to ensure energy level.

Use the sample table to perform quick measurements

of both Standards and Samples.

Easily append the sample table to add new samples

or even revise calibration curves either by manual

introduction or using an Autosampler.

View up-to-date calibration curves in 1st, 2nd, or 3rd

order using a standard calibration or standard addition.

Perform retrospective curve fits to ensure optimum

correlation.

View real-time signal acquisition for flame and

hydride generation analysis.

AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 22

Page 21: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

22

SpecificationsSpectrometer system

Wavelength range 190nm - 900nm

Light Source Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

Modulation Square Wave Pulse

Modulation frequency 100hz Self reversal (SR) background, 400hz Deuterium Arc (D2) background

Monochromator

Grating 1800 grooves/mm diffraction grating

Blazed Wavelength 250nm

Focus 300nm

Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm (Software selectable)

Scan mode Automatic

Photometric Type Single Beam

Wavelength Accuracy +/-0.15nm

Wavelength Resolution 0.2nm +/-0.02nm

Wavelength Reproducibility < 0.05nm

Baseline Stability 0.005Abs/30min

Background Correction Deuterium Arc (D2) 1.0Abs, Self Reversal (SR) 3.0Abs

Flame Analysis

Flame Type Air/Acetylene

Sensitivity (Cu) 2ug/ml Absorption >0.28Abs

Characteristic Concentration Cu < 0.02ug/ml

Detection Limit Cu < 0.004ug/ml

Repeatability Cu < 0.7%

Burner head Titanium Alloy

Nebuliser Inert Adjustable Nebuliser, Flow Rate from 2ml - 6ml/min. Pt/Ir capillary available for high acid concentration

Pre-mix Chamber Corrosion Resistant

Safety Functions Burner switch, Flame Sensor, Gas Leak Sensor, Low Gas Pressure Sensor, Drain Trap Sensor, Power Loss Protection

Data Processing

Operating Program AA Win software

Analytical Methods Flame AA, Flame AE, Hydride

Readout Mode Continuous, Manual, Peak Height, Peak Area

Calibrations Multi-Standard Calibration, Standard Addition, Interpolation

Data Storage Analytical results, Instrument and measurement parameters, Signal profile,Calibration curve

Power Requirements 220Vac 50/60hz 200W

Dimensions 110cm x 54cm x 54cm 75Kg

Standard packaging1 Main Unit1 PG990 Instruction Manual1 Cook Book1 Safety Manual1 System Validation Document

1 Air/Acetylene Burner1 Inert Adjustable Nebuliser8 Hollow Cathode Lamp Holders1 Power Cable1 Gas Tubing Air

1 Gas Tubing Acetylene1 Drain Trap and Tubing1 Tool Kit1 Various Gas Fittings

AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 23

Page 22: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

l Ultra low noise whenrunning – just 53-59dB (A)

l 100% Oil Free Design

l Efficient, Horizontal Twinpump unit

l Innovative CompactDesign, perfect forlimited space

l 10 bar Maximum pressure

l 15 Litre tank for stable airsupply

l 104L/min supply at 3 bar

l Easy to ship only 14Kgl Universal design

l Full reaction cycle frompress of start button

l Supplied withtemperature controlledheated absorption cell

l Cell is easily installed withburner attachment

l Can be used for Mercurycold vapour analysis

l Sensitivity for mostelements <1ng/ml

l Only 2.0ml – 2.5ml persample required

l RSD < 3%

l Quick analysis < 30seconds per measurement

l Sequential auto-samplerallows the automatedanalysis of 50 or more

samples and calibrationstandards.

l The system allows forautomatic update ofstandard values and curveparameters by using upto 8 standards, blanksand QC standards.

l A double wash station for probe wash avoidssample and standardcontamination.

l An inert Teflon probe issupplied as standard.

23

AccessoriesInert Adjustable Nebuliser (500-011) Flame Autosampler

For more details and ordering information please visit our website www.pginstruments.com

Hydride Unit (990-007)

Air Compressor (GS-003)

Acetylene Regulator (GS-001)

l Direct fitting to gas cylinder

l Comply to British Standards

l Supplied with hose fittingand crimp

l Various gas cylinderfittings available

l Specify fitment toEuropean standard

l Universal fitting

l Stainless steel construction

l All fittings supplied

l 150mm polymer fan

l 240Vac 50/60hz

l 300mm diameter hood,adjustable height

l Adjustable bends from 0° to 90°

Fume Extraction System

Acetylene Flame Arrestor (GS-004)

l Direct fitting to gasregulator output

l Required for acetylene gas

l Non-resetting easy to replace

l Excellent RSD’s typically<1.0%

l Typical read back valuesbetter than 2%

l Enhanced sensitivity

l Can be used on all PGInstruments AA500 andAA990 series atomicabsorption systems

l Redesigned spray chamberto ensure excellentdrainage properties

l Acid resistant nebuliserwith Pt/Ir capillary (500-012)

l Adjustable uptake from 2-6ml/min

l Fully adjustable impactbead

Patent pending

AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 24

Page 23: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

Atomic Absorption SpectrometerQualification Kit

24

AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 25

Page 24: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

25

The purpose of the Qualification Kit is to offer

both laboratory analysts and regional distributors

the flexibility to perform a full installation and

operational qualification on Atomic Absorption

Spectrometers manufactured by PG Instruments.

The work instructions within the qualification work book

have been developed with considerations of the

requirements of the Pharmacopoeia to ensure compliance

with good laboratory practice.

The documentation supplied with the kit, guides the user

through the qualification as it offers detailed instructions

on how to carry out the tests, document and record

results and perform any necessary corrective action. The

comprehensive kit offers all the materials required to

complete the qualification.

The contents of the kit are as follows:

l Qualified Hg Hollow Cathode Lamp – For determining

the wavelength accuracy.

l Qualified Cu Hollow Cathode Lamp – For determining

the flame and graphite analytical tests.

l Qualified Standard Solution – For determining the

flame analytical tests.

l Qualified Standard Solution – For determining the

graphite analytical tests.

l Filter Tool – For determining the photometric

accuracy.

l Certificates for Solutions.

l Qualification Workbook.

l USB Flash Drive containing qualification workbook

and qualification worksheets.

AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 26

Page 25: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

26

Atomic FluorescSpectroscopy

AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 27

Page 26: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

The AFS technique is widely used for the

determination of hydride forming elements

and Mercury analysis. The technique provides

an alternative to the conventional method of

connecting a hydride generator to an Atomic

Absorption Spectrophotometer (AAS). Due to

the high intensity Hollow Cathode lamp source

and low baseline noise offered by this

technique, the usable sensitivity is greatly

improved offering very low detection limits.

The AFS instrument fulfils the analysis by means of

simultaneous detection, accurate sample introduction

and stable furnace temperature control complementing

the more widely used AAS flame/graphite systems.

The Atomic Fluorescence Spectroscopy technique is used

to measure samples containing both hydride forming

elements and mercury in a variety of analytical sectors.

Due to its design and functionality, the instrument offers

enhanced sensitivity, reduced interference and excellent

limits of detection (ppt).

27

cence

AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 28

Page 27: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

28

S IMU LTANEOUS ATOM IC F L UOR E SC ENCE S P EC T ROMET E R

AF402

AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 29

Page 28: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

The AF402 is an ideal instrument for elementalanalysis in various market and researchindustries including:

l Agricultural l Food and Beverage

l Public Health l Clinical

l Pharmaceutical l Geological

l Metallurgical l Petrochemical

STANDARD F EATURES

Light Source

l High Intensity Hollow Cathode lamps for greater

intensity and stability.

l Up to three lamps can be installed for simultaneous

analysis.

l All lamps are uniquely data coded offering important

information to the PF Win operating software.

Optical System

l Shielded optical design greatly reduces light interference.

l Enhanced signal to noise ratio for increased analytical

sensitivity.

l Unique optical configuration for increased fluorescence

intensity. Up to twice the fluorescence intensity found

in traditional AFS systems.

l High Quantum Solar Blind Photomultiplier Tube fitted

as standard to ensure optimum stability.

Atomiser System

l High precision quartz atomiser tube designed for

optimum performance, durability and long life.

l Self-igniting Argon/ Hydrogen flame with software

controlled heater coil.

l Adjustable height control for improved optimisation.

l Integrated fume exhaust system to decontaminate

pollution.

29

AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 30

Page 29: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

Hydride generator

l Built in Hydride generator with continuous flow.

l Multi-pump with individual pressure adjustment for

uptake control of reagents and carrier liquids.

l Introduction of sample using motorised syringe drive

and unique three way control valve. Software

controlled for greater accuracy.

l High efficiency glass liquid separator which optimises

the separation minimising pressure fluctuations and

improving measurement precision.

l Reagent compartment stores reagents safely and

cleanly. Storage for up to four containers.

l Low level reagent monitoring.

l Embedded PC system built into the instrument as

standard. Pre-installed PFWin software, user manual

and windows operational system.

Autosampler

l Integrated autosampler.

l XYZ configuration.

l 2 x 45 vial trays for automated sample introduction.

l Auto dilution using motorised syringe drive and

selection valve.

l Full calibration using only one stock standard solution.

l Fully controlled by the PF Win software.

Electronic Control System

l High technology electronics and PCB components.

l Rear mounted and separated electronic section to

eliminate carry over from hydride technique.

l Built in embedded PC operating system. No extra

PC control required.

l Windows operating software.

l PFWin instrument control software.

Detection Limits

Element Detection Limit(ug/l) RSD %

Arsenic (As) <0.01ug/l <1%

Bismuth (Bi) <0.01ug/l <1%

Cadmium (Cd) <0.001ug/l <1%

Germanium (Ge) <0.05ug/l <1%

Mercury Hg) <0.001ug/l <1%

Lead (Pb) <0.01ug/l <1%

Antimony (Sb) <0.01ug/l <1%

Selenium (Se) <0.01ug/l <1%

Tin (Sn) <0.01ug/l <1%

Tellurium (Te) <0.01ug/l <1%

Zinc (Zn) <1.0ug/l <1%

30

AF402continued

AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 31

Page 30: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

PFWinSoftwareThe intuitive software package provides ease of

operation, method development control and data

acquisition. Software wizards simplify the operation

and configuration.

AFWin offers real time display of fluorescence intensity.

Full adjustment of current for all hollow cathode lamps

is provided. Lamps are set for optimal performance.

Where parameters are input manually, PFWin software

will prompt the suggested parameters to complete the

configuration for the analysis.

Detailed information and results are shown for each

element analysed.

Calibration information as well as results for standards

are shown for each element.

Detailed results for the analysis can be seen and saved.

Reporting and QC control allows printouts of spectra,

standard calibration curves, analysis and signal data.

Report of operating parameters can be saved or printed

for future information.

31

AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 32

Page 31: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

32

SpecificationsSample Atomisation

Atomiser Quartz tube furnace with auto ignition of argon/hydrogen flame

Furnace heating Computer controlled heating

Hydride Generator Continuous flow high performance for cold-vapour mercury and hydride determinations of As, Se, Te, Bi, Sb, Sn, Zn, Pb, Cd, Ge

Gas Requirement High purity Argon gas(99.99%) 30psi pressure

Sample and delivery

Peristaltic Pump 3 channel pump with 3 adjustable pressure control clamps and programmable

speed control.

Exhaust System Built in with filter to decontaminate pollutants

Gas/Liquid Separator High efficiency two-stage gas-liquid separator.

Autosampler

Type Integrated XYZ

Sample Introduction High sample capacity, automated introduction of sample and standards bymotorised syringe drive.

Sample capacity 2 x 45 standard test tube sample racks

Optics

Optical Design Short focal length, non-dispersive integrated optical design.

Light source 3 channel simultaneous element analysis using computer controlled. Modulated and pulsed, hollow cathode light source.

Baseline stability <2%

Linear range >103

Computer system

Type Built in embedded PC system

Operating system Windows

Operating software PFWin software

Safety Alarm for low gas <60ml/min. Gas cut off in the event of power supply loss

Power requirements 220Vac ±10% 50/60hz, 300W

Dimensions 100.6cm x 58cm x 55cm

AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 33

Page 32: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

Argon Gas Regulator

l Direct fitting to gas cylinder

l Comply to British Standards

l Supplied with hose fitting and crimp

l Various gas cylinder fittings available

l Regulator for high purity Argon 99.99%

l Specify fitment to European standard

Accessories

33

Fume Extraction System

l Universal fitting

l Stainless steel construction

l All fittings supplied

l 150mm polymer fan

l 240Vac 50/60hz

l 300mm diameter hood, adjustable height

l Adjustable bends from 0° to 90°

For more details and ordering information please visit our website www.pginstruments.com

AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 34

Page 33: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

F LAME PHOTOMET E R

FP902

34

AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 35

Page 34: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

35

Flame photometry provides a simple method

of analysis and concentration determination of

elements which cannot easily be measured

using any other technique. PG Instruments

application notes for users of our versatile

new flame photometers cover a wide range

of industrial sectors, from food and drink to

cement, minerals and glass, as well as

agricultural, biological and clinical applications.

The PG Instruments FP902 Flame Photometer offers

the combination of clinical, industrial and education

applications in ONE instrument. It gives accurate, fast and

precise analysis of sodium, potassium, calcium and lithium

in one simple aspiration.

The FP902 uses a soft touch key pad for ease of data entry

and features electronic ignition, automatic flame failure

safety and will operate using butane, natural gas or LPG.

NOWWITH

BARIUM

AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 36

Page 35: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

36

TYP I CAL APP L I CAT IONS

l Soil and Agricultural Analysis

l Biological Fluids

l Petrochemical Industry

l Food and Drink Analysis

F EATURES & FUNCT IONS

l Five element measurement in a single aspiration

(Na, K, Li, Ca and Ba).

l Curve calibration using up to 5 standards.

l Calibration curve fit routines first order and

second order.

l Multiple calibration curve saving facility.

l Sample data storage.

l Printer attachment.

l Data displayed in concentration units ie. ppm,

meq etc.

AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 37

Page 36: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

Specifications

37

ModeGeneral Analytical

Serum UrineApplications

Na: 0.1-100 ppm Na: 0-200 Na: 0-250Up to 250 meq/l, 1:100 dil 1:100 dil 1:100 dil

K: 0.1-100 ppm K: 0-10 K: 0-100

RangeUp to 250 meq/l, 1:100 dil 1:100 dil 1:100 dil

Ca: 15-100 ppm Ca: - Li: 0-2 Ca: - Li: 0-10Up to 250 meq/l, 1:100 dil 1:5 dil 1:2 dil

Li: 0.5-100 ppmUp to 250 meq/l, 1:100 dil

Sensitivity General Mode: Na:0.5 ppm, K:0.5 ppm, Li:0.5 ppm, Ca:15 ppm, Ba:30 ppm

Filters Filters for Sodium, Potassium, Lithium, Calcium and Barium are included

Resolution 0.1 ppm/meq

Reproducibility + 2% FS, & + 2 Digits

Curve Fit Accuracy + 2% FS

Display 20 x 4 Alphanumeric backlit LCD display

Flame System LPG & dry oil free air

Detector Silicon Photodiode

Calibration Up to 5-Point Calibration with curve fitting software

Gas Control Fully Adjustable

Ignition System Auto Ignition

Atomiser Axial flow type

RS-232C Interface RS-232 PC Software available

Power 230 V + 10% AC, 50/60 Hz

Dimensions 365 x 245 x 220 mm (L x B x H) (Approx.)

Weight Main Unit: 7.5Kg. (Approx.)

Compressor UnitAir Supply Oil free compressor unit with pressure regulator

Combustion Gas LPG Controlled by precision regulator

Power 230 V + 10% AC, 50/60 Hz

Dimensions 290 x 255 x 210 mm (L x B x H) (Approx)

Weight 8Kg. (Approx.)

AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 38

Page 37: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

l 2 inch lamps available

l 70 single-element lamps

l More than 120 multielement lamps, up to 5 element per lamp

l Low current operation

l Long life >5000mA Hours

l Designed for use with SRbackground system

Consumables

Hollow Cathode Lamps Multi Element Standardsl 500ml volume bottles

l More than 40 individualelements available

l 1.000g/ml (1000ppm)concentration

l Individual elements madeup in a choice of acidsolutions

l Glass construction

l Fixed flow rate for easyinstallation.

l Acid resistant to 5%

l Easily replaced

Glass Fixed Flow Nebuliser Standard Nebuliser (Acid Resistant available)

38

AA500

l Pyrolytically coatedgraphite tube

l Supplied with or withoutplatform

l High quality long life tubes

l Can be used for largersamples >20ul

Graphite Tubes Sample Uptake Tubesl Replacement sample

uptake tubes

l Attached filter to eliminatesolid uptake

l Standard length

l Easily replaced

l High energy lamp

l For use with AA500instrument

l Easy fit

l No alignment required

Deuterium Lamp Auto Sampler Vials – Flame Samples

l Re-useable glass vials

l For use with AS500 AutoSampler

l Larger volume for samples6ml

l 11/2 inch standard lampfitting

l Excellent RSD’s typically<1.0%

l Typical read back valuesbetter than 2%

l Enhanced sensitivity

l Can be used on all PGInstruments AA500 andAA990 series atomicabsorption systems

l Redesigned spray chamberto ensure excellentdrainage properties

l Fully insert nebuliser

l Adjustable uptake from 2-6ml/min

l Fully adjustable impactbead

AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 39

Page 38: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

39

l Re-useable glass vials

l For use with AS500 AutoSampler

l Larger volume forstandards 12ml

Auto Sampler Vials – Flame Standards Auto Sampler Vials – Graphite Samples/Standards

l Re-usable vials

l For use with AS500autosampler

l 1.5ml volume for samplesand standards

l Re-useable glass vials

l For use with AS500 AutoSampler

l Larger volume for modifiersolution 12ml

Consumables

Auto Sample Vials – Graphite Modifier Solutions Micro Pipettel Used for manual injection

l Adjustable volume

l Accurate dispensingvolume

l For use with AA500Graphite Furnace

l Disposable tips

l For use with micro pipette

Micro Pipette Tips

AA500

AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 40

Page 39: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

Consumables

40

l Re-useable glass vials

l For use with AS990 AutoSampler

l Larger volume for samples

Auto Sampler Vials – Flame Samples/Standards Auto Sampler Vials – Wash

l For use with AS990 AutoSampler

l Large volume for wash

l Re-usable

Sample Uptake Tubesl Replacement sample

uptake tubes

l Attached filter to eliminatesolid uptake

l Standard length

l Easily replaced

AA990

l 2 inch lamps available

l 70 single-element lamps

l More than 120 multielement lamps, up to 5 element per lamp

l Low current operation

l Long life >5000mA Hours

l Designed for use with SRbackground system

Multi Element Standardsl 500ml volume bottles

l More than 40 individualelements available

l 1000g/ml (1000ppm)concentration

l Individual elements madeup in a choice of acidsolutionsl 11/2 inch standard lamp

fitting

Hollow Cathode Lamps

l Glass construction

l Fixed flow rate for easyinstallation.

l Acid resistant to 5%

l Easily replaced

Glass Fixed Flow Nebuliser Acid Resistant Nebuliser

l High energy lamp

l For use with AA500instrument.

l Easy fit

l No alignment required.

Deuterium Lamp

l Excellent RSD’s typically<1.0%

l Typical read back valuesbetter than 2%

l Enhanced sensitivity

l Can be used on all PGInstruments AA500 andAA990 series atomicabsorption systems

l Redesigned spray chamberto ensure excellentdrainage properties

l Fully insert nebuliser

l Adjustable uptake from 2-6ml/min

l Fully adjustable impactbead

AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 41

Page 40: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

41

Consumables

l Re-usable glass cups

l Used in XYZ autosamplerfor standard solutions

Sample Cups Small Standard Solutions

l 500ml volume bottles

l Individual elementsavailable for Sb, As, Bi, Cd,Ge, Pb, Hg, Se, Te, Sn, Zn

l 1.000g/ml (1000ppm)concentration

Heater Coilsl Replacement wire coils

l Fits around the QuartzAtomiser

l Used for heating theatomiser when used forhydride analysis

l Regular replacementsuggested

AF402

l High performance – Highoutput lamps

l Lamps designed for usewith AF402 system

l Built in circuit for codingand usage recording

l Available for analysis of avariety of elementsincluding: Sb, As, Bi, Cd,Ge, Pb, Hg, Se, Te, Sn, Zn

Quartz Atomiserl Quartz Glass – to

withstand heat andchemicals

l Replacement required atregular intervals

l Inputs for gas and hydridevapout

Hollow Cathode Lamps

l Quartz Glass – towithstand high acidsolutions

l Designed to fit in the XYZautosampler

Injection Tubes Glass Mixing Chamberl Quartz glass

l Built in gas separator

l Easily replaced

l Accurate high quality

l Used for accurate uptakeof sample and carrier liquid

l Requires regular flushing

Syringe

AA SPEC BRO – 060_Layout 1 09/10/2013 12:43 Page 42

Page 41: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

42

l Matching air compressordesigned only for use withFP902 instrument

l Oil free air

l Adjustable air supply withgauge

l 220v 50/60hz

Air Compressor Nebuliser

l Cross flow design

l Adjustable uptake rate

l High quality capillary tube

l Fits into premix chamber

l Designed for use with lowpressure propane flame

l Easily removed for cleaning

Consumables

Burner Capillary Tubesl Fit onto capillary tube of

nebuliser

l Optimised length

l Used for sample uptake

l Easily fitted and replaced

Sample Cupsl Re-usable glass cups

l Used for holding samplesand standard solutions

l Small volume size for usewith FP902 instrument

l Fine wire length

l Used to clean blockage incapillary tube of nebuliser

Cleaning Wires

FP902

AA SPEC BRO – 060_Layout 1 09/10/2013 12:43 Page 43

Page 42: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

We reserve the right to modify, revise/upgrade, suspend or discontinue any Product in whole or in part, either temporarily or permanently, with or without notice.

AA SPEC BRO – 060_Layout 1 09/10/2013 12:43 Page 44

Page 43: ELEMENTAL SPECTROSCOPY - John Morris Scientific · ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 2. Contents ... their own advantages

instruments

i

ALMA PARK, WIBTOFT

LEICESTERSHIRE, LE17 5BH

UNITED KINGDOM

T: +44 (0)1455 220131

F: +44 (0)1455 220025

www.pginstruments.com

V1.2013

AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 1