28
® ® ELF DSX 124317-5 A0 USER MANUAL

ELF DSX User Manual

  • Upload
    others

  • View
    18

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ELF DSX User Manual

®

®

ELF DSX

124317-5 A0

USER MANUAL

Page 2: ELF DSX User Manual

ii Telect, Inc. 124317-5 A0

ELF DSX User ManualDocument Number 124317-5 A0Copyright© 2001, Telect, Inc., All Rights Reserved.

Telect® and Connecting the Future® are registered trademarks of Telect, Inc., 2111 N. Molter Rd., Liberty Lake, Washington 99019

Technical Support (USA):By e-mail: [email protected] phone: 888-821-4856 or 509-921-6161

Note:Telect assumes no liability from the application or use of these products. Neither does Telect convey any license un-der its patent rights nor the patent rights of others. This document and the products described herein are subject to change without notice.

Page 3: ELF DSX User Manual

Contents

®

®

1 Descriptions

ELF DSX ..................................................................................... 1-1Capabilities ............................................................................ 1-2Features.................................................................................. 1-2Part Numbers ......................................................................... 1-2

System-Level Applications.......................................................... 1-2Main Assemblies.......................................................................... 1-3

Rack-Mount Systems ............................................................. 1-3Wall-Mount Systems ............................................................. 1-3

Specifications............................................................................... 1-4Electrical ............................................................................... 1-4Physical ................................................................................. 1-5

2 Installation

Installation Considerations .......................................................... 2-1Location and Space................................................................ 2-1Tools and Equipment ............................................................. 2-2Technical Support (USA) ...................................................... 2-2

Inspection..................................................................................... 2-2Installation Procedure for Rack-Mount ELF DSX ...................... 2-3

Rack-Mount Options.............................................................. 2-3Rack Mounting and Cabling Procedure................................. 2-3

Installation Procedure for Wall-Mount ELF DSX ....................... 2-5

3 Electrical Operation

Schematic, Rack-Mounted Wire-Wrap........................................ 3-1Schematic, Rack-Mounted BNC.................................................. 3-2Schematic, TFA Wire-Wrap......................................................... 3-2Schematic, Rack-Mounted RJ-48C.............................................. 3-3Schematic, TFA RJ-48C .............................................................. 3-3

124317-5 A0 iii

Page 4: ELF DSX User Manual

4 User Functions

Monitoring ................................................................................... 4-1Patch And Roll............................................................................. 4-1

5 Service

Owner Maintenance ..................................................................... 5-1In Case Of Difficulty ................................................................... 5-1

Technical Support (USA) ...................................................... 5-1In-Warranty Service ..................................................................... 5-2Out-Of-Warranty Service............................................................. 5-2Repacking For Shipment ............................................................. 5-2

iv Telect, Inc. 124317-5 A0

Page 5: ELF DSX User Manual

1 Descriptions

ELF DSX

Telect’s ELF DSX serves as a small, “edge” connection device in locations where equipment density is important.

®

®

124317-5 A0 1-1

Page 6: ELF DSX User Manual

1 Descriptions ELF DSX User Manual

Telect’s T1/E1 low-profile front cross connect (FXC) rack- and wall-mount ELF panels are designed to fit on the edge of a 3G wireless network, at the base transceiver station (BTS). The panel’s compact front access allows maximum density and simplified monitoring.

Capabilities

• Expandable system—up to three ELF modules per chassis• T1/E1 signal rates

Features

• Wire-wrap, BNC I/O, or RJ-48C connections.• Front cross-connect, including a shield ground pin for ITU G.703 com-

piance.• Universal rack mount—19" (48.3 cm) or 23" (58.4 cm), using 1 EIA

rack unit (RU) of space. Also mounts in an equipment cabinet.

• Total Front Access (TFA) versions can be mounted in the standard ELF chassis or in an optional wall bracket.

Part Numbers

• ELF-1008-1100 8-termination module, wire-wrap I/O

• ELF-1008-1200 8-termination module, BNC I/O

• ELF-1008-1800 8-termination module, RJ-48C

• ELF-3006-1100 6-termination module, wire-wrap TFA

• ELF-3006-1800 6-termination module, RJ-48C TFA

• ELF-0000-2400 3-module chassis for all ELF modules

• ELF-0000-0600 Wall bracket for ELF-3008-1100 & ELF-3006-1800

• ELF-0005-0001 12 x 4 Alarm Pin Block

SYSTEM-LEVEL APPLICATIONS

• Wireless base transceiver station (BTS)

• Customer premises

• Controlled environment vault

• Co-location

1-2 Telect, Inc. 124317-5 A0

Page 7: ELF DSX User Manual

ELF DSX User Manual 1 Descriptions

®

®

MAIN ASSEMBLIES

Rack Mount Systems

The chassis holds up to three 8-termination modules, 6-terminal-TFA modules, or 12x4 alarm pin blocks for an expandable system. The backplanes of 8-termination modules hold either wire-wrap pins, BNC connectors, or RJ-48C connectors for I/O connections.

Wall-Mount Systems

The optional wall-mounted bracket holds one 6-termination, total front ac-cess (TFA I/O & X-CON) wire-wrap or a 12 x 4 alarm pin block.

1357

246

3 1

Chassis Backplane, RJ-48C

GroundStud

CableTie-Down

Bar

8 8 6

7

4 2

5 3 1

8 6

7

4 2

5

Bar

CableTie-Down

Chassis Backplane, BNC

StudGround

Bar

CableTie-Down

Chassis Backplane, Wire-Wrap

StudGround

124317-5 A0 1-3

Page 8: ELF DSX User Manual

1 Descriptions ELF DSX User Manual

SPECIFICATIONS

Electrical

E1 T1

Return Loss 12 dB 51 kHz to 102 kHz18 dB 102 kHz to 2048 kHZ14 dB 2048 kHz to 3073 kHz

26 dB 772 kHz

Interchannel Crosstalk -60 dB at bit rate (2.048 Mbps) -60 dB at bit rate (1.544 Mbps)

Adjacent Channel Crosstalk -60 dB at bit rate (2.048 Mbps) -60 dB at bit rate (1.544 Mbps)

Insertion Loss 0.5 dB at bit rate (2.048 Mbps) 0.5 dB at bit rate (1.544 Mbps)

Monitor Level –20 dB ± 1.5 dB at bit rate (2.048 Mbps)

–20 dB ± 1.5 dB at bit rate (1.544 Mbps)

1-4 Telect, Inc. 124317-5 A0

Page 9: ELF DSX User Manual

ELF DSX User Manual 1 Descriptions

®

®

Physical

1.75 in.(4.4 cm)

19 in.(48.3 cm)

3.5 in.(8.9 cm)

5.5 in.(14.0 cm)

Rack Mount

124317-5 A0 1-5

Page 10: ELF DSX User Manual

1 Descriptions ELF DSX User Manual

1-6 Telect, Inc. 124317-5 A0

Page 11: ELF DSX User Manual

2 Installation

®

®

INSTALLATION CONSIDERATIONS

CAUTION!CAUTION! This product must be installed and maintained only by qualified technicians.

VORSICHT! Nur von qualifizierten Technikern installiert werden und instand gehalten werden.

PRECAUCIÓN! Ser instalado y ser mantenido solamente por los técnicos autorizados.

ATTENTION! Ce produit doit être installé et entretenu unique-ment par des techniciens qualifiés.

ALERT!ALERT! These instructions presume you have verified that the Telect equipment being installed is compatible with the rest of the system, including power, ground, circuit protection, signal characteristics, equipment from other vendors, and local codes or ordinances.

Location and Space

• The ELF DSX chassis mounts in a 19" (48.3 cm) or 23" (58.4 cm) equipment rack (EIA or WECO) or inside an equipment cabinet. On an EIA rack, it takes up one RU of space (1.75"/4.4 cm).

• The ELF DSX wall bracket requires 6" (15.2 cm) by 1.8" (4.5 cm) of wall space.

124317-5 A0 2-1

Page 12: ELF DSX User Manual

2 Installation ELF DSX User Manual

Tools and Equipment

• Standard and wire-wrap tools

• A chassis ground wire—14 AWG minimum with ring terminal.

Use listed components (UL-recognized, CSA, ETL, TUV agency) and crimping tools.

Technical Support (USA)

By e-mail: [email protected] phone: 888-821-4856 or 509-921-6161

INSPECTION

Compare the contents of the ELF DSX shipping container with the packing list. Call Telect if you are missing anything.

NOTE

Telect is not liable for shipping damage.

If the shipping container is damaged, keep it for the carrier’s inspection.Notify the carrier and call Telect’s Customer Service Department:

1-800-551-4567 or 1-509-926-6000

Keep the container until you have checked equipment operation. If you ex-perience any kind of problem, call Telect’s Customer Service Department.Use the original, undamaged container if you are instructed to return theELF DSX to Telect.

2-2 Telect, Inc. 124317-5 A0

Page 13: ELF DSX User Manual

ELF DSX User Manual 2 Installation

®

®

INSTALLATION PROCEDURE FOR RACK-MOUNT ELF DSX

Rack-Mount Options

You can leave the mounting brackets in their default location on the chassis for 19" (48.3 cm) flush mounting. Or you can remove and reposition the brackets for a number of different mounting options:

Rack Mounting and Cabling Procedure

Step Action

1. Insert one to three ELF DSX mod-ules into the chassis. Secure each module to the chassis faceplate with two screws (provided).

2. Mount the ELF DSX with four screws (#12 or M6, both sets are provided).

3. Attach a 14 AWG ground wire with a ring lug to the 8-32 ground stud on the rear panel. Connect the opposite end to a ground point on the rack.

ELF DNX, Right-End View

19" Orientation 23" Orientation

(1) (2)

(3)

(A) (B)

Bracket Position

(End Views)

Mount Option

1A1B2A2B3A3B

FlushExtendedRecessedRecessed*FlushExtended

*The recess is very slight at this position, almost flush.

ELF DSX, Right-End View

124317-5 A0 2-3

Page 14: ELF DSX User Manual

2 Installation ELF DSX User Manual

4. Attach in/out (I/O) cables (at the rear for chassis systems; at the front for TFA DSX modules used in chassis). Connectors are la-beled. Use cable ties and the tie-down bar to manage the cables.

5. Make cross-connects at the front of the panel. If required, secure jumpers to the front tie-down bar using cable ties inserted through the slots in the bar and then wrap the tie around the jumpers.

A B

A TO B IS EXAMPLE ONLY

T

R

T

R

SG

OUT

IN

A B

Out T “A” to In T “B”Out R “A” to In R “B”In T “A” to Out T “B”In R “A” to Out R “B”SG to SG (E1)

T

R

T

R

SG

OUT

IN

JUMPER ROUTING SCHEMEBETWEEN PINS SHOWN HEREIS EXAMPLE ONLY

Tie-Down Bar Cable Tie

Wire Wrap

2-4 Telect, Inc. 124317-5 A0

Page 15: ELF DSX User Manual

ELF DSX User Manual 2 Installation

®

®

NOTE

There are no LEDs and therefore no tracer lamp (TL) connectionsto make. A shield ground cross-connect pin is provided for cross-connecting shield ground with the drain wire.

6. Record the circuits on the front designation card.

INSTALLATION PROCEDURE FOR WALL-MOUNT ELF DSX

RJ-48C

Wall Bracket

TFA ELF Module

124317-5 A0 2-5

Page 16: ELF DSX User Manual

2 Installation ELF DSX User Manual

Step Action

1. Use four, suitable panhead screws to secure DSX bracket to wall.

Screws are not included.

2. Mount the ELF DSX in bracket using two M3 screws provided.

The away-facing surfaces of the mounting ears on the module are stripped of paint to ensure a good electrical ground. For grounding, use the ring lug and star lockwasher provided along with a #14 AWG (min.) copper wire.

3. For TFA Wire-Wrap DSX modules,

a. Wire-wrap in/out (I/O) cables to the left of the patch area. Use cable ties and the tie-down bar to manage cables.

b. Make cross-connects at the right of the patch area. Again, use cable ties and tie-down bar to manage cables.

The example below shows network element 1 (NE 1) cross-con-nected to NE 6.

2-6 Telect, Inc. 124317-5 A0

Page 17: ELF DSX User Manual

ELF DSX User Manual 2 Installation

®

®

NOTE

There are no LEDs and therefore no tracer lamp (TL) connec-tions to make. A shield ground cross-connect pin is provided forcross-connecting shield ground with the drain wire.

c. Record the circuits on the designation card and affix anywhere.

4. For TFA RJ-48C DSX modules, make input/output (I/O) intercon-nections along the bottom row of RJ connectors and cross connec-tions along the top row, as shown in the following illustration. Record the circuits on the designation card and affix anywhere.

124317-5 A0 2-7

Page 18: ELF DSX User Manual

2 Installation ELF DSX User Manual

2-8 Telect, Inc. 124317-5 A0

Page 19: ELF DSX User Manual

3 Electrical Operation

®

®

SCHEMATIC, RACK-MOUNTED WIRE-WRAP

TRTR

SGnd

TRTRSGnd

FrontCross-Connect

Out

Out

In

In

MON

OUT

IN

Shield Gnd

R

Equipment I/O

124317-5 A0 3-1

Page 20: ELF DSX User Manual

3 Electrical Operation ELF DSX User Manual

SCHEMATIC, RACK-MOUNTED BNC

SCHEMATIC, TFA WIRE-WRAP

XFR OUT

IN

TRTR

SGnd

FrontCross-Connect

Out

In

MON

OUT

IN

Shield Gnd

R

120/75Ω

IN

TR

IN

S. GND.

OUTRT

MON

OUT

R1

R2

S. GND.

TR

TR

IN

OUT Front Cross-Connect

Front Input/Output

3-2 Telect, Inc. 124317-5 A0

Page 21: ELF DSX User Manual

ELF DSX User Manual 3 Electrical Operation

®

®

SCHEMATIC, RACK-MOUNTED RJ-48C

SCHEMATIC, TFA RJ-48C

X-CONS. GND.

OUT

INRT

RT

OUT

S. GND.

IN

RT

I/O

IN

OUT

MON R1

R2

87654321

RT

IN

OUT

MON R1

R2

8

1

4

67

5

32

X-CON

R

TR

T

IN

OUT

RJ SHIELD GND.

R 1

8

RT 5

OUT3

T 2

4

IN67

I/O

CHASSIS GND.

124317-5 A0 3-3

Page 22: ELF DSX User Manual

3 Electrical Operation ELF DSX User Manual

3-4 Telect, Inc. 124317-5 A0

Page 23: ELF DSX User Manual

4 User Functions

®

MONITORING

To monitor the OUT signal from an ELF DSX module, plug one end of a single patch cord into the MON port and the other end into the monitoring equipment. The MON port connection is nonintrusive.

PATCH AND ROLL

Patching maintains a circuit by temporarily cross-connecting to back-up equipment so that technicians can repair or test the lines of the permanent connection. Patching and rolling allows a circuit to be moved from an ex-isting facility to a new or spare facility, including new permanent cross-connects.

NOTE

If you use a dual patch plug, remember to twist the plug on one end of thecord so that it is reversed (i.e., turned upside down) from the other end.

Step Action

1. Patch B to spare facility C. Insert patch cords in C, then in B.

2. Remove the cross connects between the A and B facilities.

®

124317-5 A0 4-1

Page 24: ELF DSX User Manual

4 User Functions ELF DSX User Manual

3. Install cross-connects between B and C.

4. Remove the patch cords between B and C. Service is established through the new cross-connects.

M

O

ISG

TRTR

A B C

OUT

IN

OUT

IN

Cross-Connect

(E1)SG

TRTR

M

O

I

M

O

I

Patch

1

A B

M

O

ISG

TRTR

A B C

OUT

IN

OUT

INSG

TRTR

M

O

I

M

O

I

Patch

A B

M

O

ISG

TRTR

A B C

OUT

IN

OUT

IN

(E1)SG

TRTR

M

O

I

M

O

I

B C

NOTE:CROSS-CONNECTS ARE SHOWNIN DIAGRAM FORM.

2

3

4

4-2 Telect, Inc. 124317-5 A0

Page 25: ELF DSX User Manual

5 Service

®

®

CAUTION!CAUTION! This product must be installed and maintained only by qualified technicians.

VORSICHT! Nur von qualifizierten Technikern installiert werden und instand gehalten werden.

PRECAUCIÓN! Ser instalado y ser mantenido solamente por los técnicos autorizados.

ATTENTION! Ce produit doit être installé et entretenu unique-ment par des techniciens qualifiés.

OWNER MAINTENANCE

Telect’s ELF DSX does not need preventive maintenance.

IN CASE OF DIFFICULTY

If problems occur after initial installation, check cable connections and grounding as described in the installation instructions in Chapter 2.

Technical Support (USA)

By e-mail: [email protected] phone: 888-821-4856 or 509-921-6161

124317-5 A0 5-1

Page 26: ELF DSX User Manual

5 Service ELF DSX User Manual

IN-WARRANTY SERVICE

Contact your Telect equipment distributor, or call a Telect Customer Ser-vice Representative:

1-800-551-45671-509-926-6000

Telect will repair or replace defective products within the limits of the war-ranty. See “Repacking for Shipment” in this section.

NOTE

Call a Customer Service Representative for a Return Material Authoriza-tion (RMA) before returning any equipment.

OUT-OF-WARRANTY SERVICE

The procedure for out-of-warranty service is the same as for in-warranty service, except that Telect charges a processing fee, and you must submit a Purchase Order along with a Return Material Authorization (RMA) before returning equipment. Call a Customer Service Representative for help get-ting these forms.

The processing fee guarantees a repair estimate and is credited against ac-tual material and labor costs.

REPACKING FOR SHIPMENT

Step Action

1. Tag the equipment showing owner’s name, address, and telephone number, together with a detailed description of the problem.

2. Use the original shipping container if possible. If you do not have it, package the equipment in a way to prevent shipping damage. In-clude the RMA inside the container and legibly print the RMA number on the outside of the package, near the shipping address.

3. Insure the package.

NOTE

Telect is not liable for shipping damage.

5-2 Telect, Inc. 124317-5 A0

Page 27: ELF DSX User Manual
Page 28: ELF DSX User Manual

Telect, Inc.2111 N. Molter Rd.

P.O. Box 665, Liberty Lake, WA 99019509-926-6000, 800-551-4567, Fax 509-926-8915

E-mail: [email protected] Internet: http://www.telect.com