9
“ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise is located in industrial area of Kyiv – Darnitsa. Specificity of the enterprise – the production of sophisticated electronic hardware, control systems and digital automated devices. The enterprise includes design and technology bureau, service of technical control and manufacturing engineering support. Today the company is ready to offer for the mining industry Automation and control systems for the mechanized complexes Head lamp explosive-proof and with Complex lighting stope in mine Lighting systems for mining machines Control systems of methane in the mine air www.elmiz.com

“ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise

Embed Size (px)

DESCRIPTION

. The lamp combined with the methane signaling device is intended for automatic control of the content of methane in the mine air and for the generation of light signals when the maximum permissible values ​​ of the volume fraction of methane. The signaling device has the following features and capabilities: when it reaches the intermediate operating threshold (2% or 1%) and more than volume fraction of methane in the air, the light source switches into an intermittent operation mode with a frequency of 1 Hz; when it reaches the upper operating threshold (2,5% or 1,5%) and more than volume fraction of methane in the air, the light source switches into an intermittent operation mode with a frequency of 10 Hz; operation in an emergency mode when the accumulator battery voltage is below the lower threshold; disconnection of the power source when short circuit in the power circuits.

Citation preview

Page 1: “ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise

“ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise is located in industrial area of Kyiv – Darnitsa. Specificity of the enterprise – the production of sophisticated electronic hardware, control systems and digital automated devices. The enterprise includes design and technology bureau, service of technical control and manufacturing engineering support.

Today the company is ready to offer for the mining industry

Automation and control systems for the mechanized complexes

Head lamp explosive-proof and with

Complex lighting stope in mine

Lighting systems for mining machines

Control systems of methane in the mine air

www.elmiz.com

Page 2: “ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise

HEAD LAMP EXPLOSION-PROOF

LUX E

Luminous flux of the main light source, minimum, lm 32 

Execution on explosion protection  RO IaSLighting in an operational mode, at a distance of 1m, minimum, lx 5000 

Lighting in an emergency mode at 1m distance, minimum, lx 2 

Rated voltage of AB, V 3,7 

AB capacity, mAh 4000 

Duration of continuous lighting of the main light source, minimum, h. 12 

Duration of continuous lighting of the auxiliary light source, minimum, h. 30

Coefficient of efficiency, minimum 0,75

Mass, maximum, g. 730

Climatic performance according to GOST 15150  UKhL5 Protection measures of the shell according to GOST 14254  IP 54

The lamp is intended for individual lighting of miner's workplace in the coal mines of all categories by the dust-gas regime.The lamp consists constructively of the following components:headlamp, in which the LED module with 2 light sources is installed for operational and emergency lighting, mode switch. The fixing of the accumulator battery on the belt of the miner is performed with metal brackets.The headlamp is connected to the battery via a flexible electrical cord with a length of 1400mm. 

Page 3: “ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise

 

.

 

LUX SM.01

Execution on explosion protection  RO IaSRated supply voltage, V 3,7

Limit deviation, V  plus 0.55 / minus 0.5Illumination from the main light source along axis at a distance

of (1000 ± 50) mm, lx, minimum 5000 

Duration of continuous lighting, h, minimum of main  light source - 14;of auxiliary auxiliary light source - 25 

Warm-up time, min., Maximum 10

Response time of a volume fraction of CH4, s, maximum 8 

Resetting ratio of the executive device 0,9 

Protection actuating current, A, maximum 3 

Disconnecting time of the power source, s, maximum 0,05 

Coefficient of efficiency, minimum 0,75 

Mass, g., Maximum 850 

The lamp combined with the methane signaling device is intended for automatic control of the content of methane in the mine air and for the generation of light signals when the maximum permissible values of the volume fraction of methane. The signaling device has the following features and capabilities:when it reaches the intermediate operating threshold (2% or 1%) and more than volume fraction of methane in the air, the light source switches into an intermittent operation mode with a frequency of 1 Hz; when it reaches the upper operating threshold (2,5% or 1,5%) and more than volume fraction of methane in the air, the light source switches into an intermittent operation mode with a frequency of 10 Hz; operation in an emergency mode when the accumulator battery voltage is below the lower threshold; disconnection of the power source when short circuit in the power circuits.

Page 4: “ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise

Module of technological control for digital signaling devices

Process Control module digital warning of methane is intended for setup, calibration and verification of digital mine methane sensors of type "LUX SM.01" and "LUX SM.TS.“

MPC provides:

 software configuration of the sensor current range from 5 mA to 160 mA; l  control voltage on the battery alarm;  software configuration signaling methane (calibration by applying calibration gas

mixtures;  software installation value thresholds in% volume fraction of methane: first threshold in the range from 0 to 2.5% by volume. the proportion of methane;  second threshold automatically to about 0.5%. the proportion of methane over the

first threshold; control thresholds specified in% volume fraction of methane;  indication of the measured values of signaling the concentration of methane.

Name of technical specifications Value

Rated supply voltage frequency (50 ± 1) Hz, V 220 (+10%,-15%)

Current consumption, A, no more 0,1

Weight, no more 2,0

Overall dimensions, mm 220х220х85

mode of operation continuous

Page 5: “ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise

Laser rangefinder mine LRM

v

. “MLR-1” is designed to measure distances and angles in underground mines, including those which are hazardous on gas and/ or dust.“MLR-1” provides protection against natural and mechanical effects. He doesn`t afraid of falling from a height of 2 meters, falling into the water, dust and splashes. Degree of protection – IP 65. Display`s backlight and its multiline provides the best reading. Also MLR1s-1 integrated with angle change sensor, so it can be used as angle meter.“MLR-1” can perform calculations with the measured values: subtraction, addition, the definition of area, volume, etc…“MLR-1” stores in memory the last 20 measurements

Typical measurement range* 0-80 m (0-262 foots)Typical measuring accuracy* + 1,0 mm/ 0,04 inches**

Smallest displayed unit 0,1 mm/1/32 inchesTilt sensor measuring accuracy

Tilt sensor measuring range+ 0,2°360°

Level and type of explosion protection RO IaProtection class IP 65Class of laser 2Type of laser 635 nm, 1mW

Batteries 2xAAA,3VDimensions 122x55x31 mm

Weight 155 gTemperature range

Storage from 25° C to 70° COperation From -10° C to 50 °C

Page 6: “ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise

The complex lighting mining machinery (KOGM.01)

Intrinsically safe voltage headlights and lamp DC V12±1

Illumination, lx, no less:– From the headlights (at a distance of 5 m on the area 5,8m2)

– On lamp (at 3 m over an area 2,2m2).

102

Current consumption, mA– headlight

– lamp

1400±50300±20

Rated supply voltage AC, 50 Hz power supply,  150

Permissible deviation supply voltage from the nominal value,% From minus 15 to plus 10

Execution on explosion protection – headlight

– lamp- power supply

RO IaS

RV 3VIaS

Dimensions, mm, not more– headlights

- lamp– power supply

Ø170х190Ø170х190200х70х80

The complex is intended for lighting workplace of driver mining machines and area of coal mines,

including dangerous on gas (methane) and (or) coal dust. As the light source lamp uses high-brightness white LEDs. Operation conditions:: - Environment temperature from -10 ° C to 35 ° C. - Relative humidity (98 ± 2)% ( with condensing humidity) at a temperature (35 ± 2) ° C. The complex includes: , lamp and power supply AGATE VH 12.60.

Page 7: “ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise

Complex lighting stope of mine (CLSM)

Complex is intended for lighting stope of mine, equipped with mechanized complexes.

The light sources used high-brightness white LEDs.

Operation conditions:- Environment temperature from -10 ° C to 35 ° C.- Relative humidity (98 ± 2)% (condensing humidity) at a temperature (35 ±

2) ° C CLSM consists of a power supply and the lamps Number of power supplies and lamps determined by the length of the working

face.Each power supply provides power to 16 lamps. Execution on explosion protection 

- power supply- lamp

РВ 2В Иа /RV 2VIaSРОИа /ROIaS

The output characteristics of the power supply channels-U , В/ -I , А/

243

Rated supply voltage AC, 50 Hz power supply, 127

Permissible deviation supply voltage from the nominal value,% From minus 15 to plus 10

The supply voltage (for the lamp), V 24 Current consumption (for lamp), A 0,2

Weight, kg- power supply

- lamp184,2

Dimensions, mm- power supply

- lamp407x225x110166x158x96

Page 8: “ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise

The control unit for the methane mining machinesIntended for automatic control of the content of methane in the mine air, issuing a warning signal and disabling the mining machine, when the level of methane in the mine air above a predetermined level.As the sensor is used thermocatalytic sensor (sensor) methane, and as a power supply - lithium - ion battery.Provides automatic control of the percentage of methane in the air minesand software installation of two values of a given level (level: the first and second) in the proportion the methane contained in mine air. Installation of the first range of the trigger level of 1% to 2% ; The second trigger level is automatically set at 0.5% above the intermediate level triggering, ranging from 1.5% to 2.5% in the share of methane content.Provides issue a warning (sound) signal when exceeding the first level triggering, as well as the issuance of the signal equipment mining machine.It provides mechanisms mining machine off when exceeding the second level of operation.

Rated supply voltage, V Maximum deviation, V

3,7 plus 0,55/ minus 0,7

Sound pressure level at a distance of 0.5 m from the unit in the audio alarm, no less, dB 80

Continuous operation without recharging the battery, an hour, no less: 14

Maximum permissible absolute error in the v. fr. of methane 4,%, no more ±0,2

Warm-up time, min, no more 10

Response time for v.fr. of methan, s, no more 8

Tripping current protection, A, no more 2,5

Efficiency, no less 0,75

Battery Li-ion

The capacity of the battery, not less mAh 7000

Degree of protection against external influences IP66