4
elumaRail eLumaRail is a modernized linear LED light system designed to operate at maximum lenghts maintaining lumen output consistency. The eLumaRail system initiates low drop out current regulators, to assure uniform brightness over running lengths in excess of 100 linear feet (30,480mm). eLumaRail system outputs are available in 2400K-6500K lights modules will provide scallop free illumination. The lens mount system is configured to allow two discreet lighting 0 0 view angles: 90 and 60 . This mount system is made of UV stabilized polycarbonate, assuring long life with-out discoloration. Features: 0 0 - Available in 90 or 60 viewing angle - Max run: 100 FT with class I power supply; 40 FT with class II - Waterproof bi-pin connector - ETL wet location listed - IP 66 rated - Rated for indoor and outdoor use. - Pedestrian Bridge Handrails - Elevation Shift Rails - Guard Rails - Stair Handrails - Pathway and Safely Illumination Rails - Accent Lighting Rails eLumaRail Pg 1. eLumarail LED Linear Handrail Solutions PREPARED BY: JOB NAME: CATALOG NUMBER: TYPE: lumarail

eLumarail LED Linear Handrail Solutions · elumaRail eLumaRail is a modernized linear LED light system designed to operate at maximum lenghts maintaining lumen output consistency

Embed Size (px)

Citation preview

elumaRail

eLumaRail is a modernized linear LED light system designed to operate at maximum lenghts maintaining lumen output consistency. The eLumaRail system initiates low drop out current regulators, to assure uniform brightness over running lengths in excess of 100 linear feet (30,480mm).

eLumaRail system outputs are available in 2400K-6500K lights modules will provide scallop free illumination. The lens mount system is configured to allow two discreet lighting

0 0view angles: 90 and 60 . This mount system is made of UV stabilized polycarbonate, assuringlong life with-out discoloration.

Features:

0 0- Available in 90 or 60 viewing angle- Max run: 100 FT with class I power supply; 40 FT with class II- Waterproof bi-pin connector- ETL wet location listed- IP 66 rated- Rated for indoor and outdoor use.

- Pedestrian Bridge Handrails- Elevation Shift Rails- Guard Rails- Stair Handrails- Pathway and Safely Illumination Rails- Accent Lighting Rails

eLumaRail Pg 1.

eLumarail LED Linear Handrail Solutions

PREPARED BY: JOB NAME:

CATALOG NUMBER: TYPE:

lum

ara

il

elumaRail

Construction

Mounting hardware (post or wall) is typically required up to 5' O.C., depending on the handrail alloy. eLumaRail is available in stainless steel and aluminum. All handrail component parts are engineered for quick installation. Field welding or cutting is typically not required. All parts are prefabricated to field dimensions and are assembled in the field with mechanical connection or epoxy. The LED light fixtureinside the cap rail is UL Listed for wet locations. Contact factory for specialty components and maintenance guidelines.

WALL MOUNT DETAILS*

may be mounted to new or

existing guardrail (by others).

Post and wall bracket spacing

must be determined by a

licensed architect or structural

engineer.

22 AWG, 300v power cord Power cord for secondary feed.Wire gauge as required for remote driver.

Locking Bracket Mount

22 AWG, 300v power cordWireway

Snap-Cover Flange

Snap Base

Tube Extension, as needed for conduit connection

To remote driver

POST MOUNT APPLICATION

60"(1.5m)

Note: 4' to 5' typical

34"(0.86m)

Light Output

Three luminous intensities are available for white light. All values below represent the initial raw lumensof the LED. IES format photometry of Lighting Facts labels represent actual light output measured inlumens and candle power. Light output losses include optical, thermal and power supply inefficiencies.

BEAM SPREAD OPTIONS

45° 10°

POST MOUNT APPLICATION

WALL MOUNT

eLumaRail Pg 2.

Electrical

elumaled houses a low voltage LED-based light fixture that is integrated into the undersideof the handrail. 24 volt 100 watt power supplies are provided as a standard. For detailedinformation regarding daisy chain limitations, remote distance limitations, power supplyoptions, and dimming options

PREPARED BY: JOB NAME:

CATALOG NUMBER: TYPE:

lum

ara

il

elumaRail

Guards are usually an essential for ramps, stairs or landings above 30".Heights will vary depending on the code. Commercial codes require a guard, 42" in height while residential codes only requires a guard to be 36" in height – always confirm these dimensions with your jurisdictional planning .

Handrails are located between 34" and 38" and have dimensional limitations for grasp ability. As such, if a 42" guardrail is called for on a stair or ramp, it will also require a secondary handrail at the appropriate height. A guard Cap Rail that is not used as a handrail would not have a grasp ability size limitation.

Guards also have opening limitations t o consider. The most common requirement is that no opening be large enough to allow a 4" sphere to pass. Infill's such as ecoresin panels, Archimesh, vertical pickets, glass or cable. An option is to install Hand Rail RHL into the handrail portion of a gua rd and use the light to wash the infill. LED Inc. now has the components that will permit wire routing through a handrail mounted in this fashion.

Rail with Top & Bottom extensions, return to floor

Rail with Top extension, return to floor

Rail with Top & Bottom extensions, return to post

Rail with Top, return to post

Handrails are in place tp provide guidance along walkways and stairwell commercial areas for illuminated safety and security.

SURFACE MOUNT

Weld Snap-On Cover Flange Base to selected post.

Mount the Flange Base to your surface using 3/8" bolts – supplied by others. Be sure to select fasteners appropriate

for your substrate.

Drop Cover Flange into place and snap -on. The secure connection of cover to base is provided by formed tabs

produced with precise tolerances.

EMBEDDED MOUNT

In new installations, use Post Sleeves or EZ Sleeves. To locate anchor holes for setting posts. If wire is to be routed through post, conduit and wire must be cast -in-place as well.

In the case of existing concrete surfaces, holes must be core drilled to accept the HRL Light posts.

Posts are set into place using Rockite® or Kwixset® anchor cement.

Use optional flange to cover the grout ring.

PREPARED BY: JOB NAME:

CATALOG NUMBER: TYPE:

lum

ara

il

eLumaRail Pg 3.

eLumaRail Handrail Attributes

elumaRail

1 2 3 4 5 6 7 8 9 10

1. PRODUCT FAMILY

06 eLumarail

2. ALLOY / FINISH

AL Aluminum

St304 Stainless steel 304

St314 Stainless Steel 314

3. SIZE

1 (7)1.66" O.D (1 1/4 p ipe size)

(available for SS & CAA)

2 1.90" O.D . (11/2” p i pe size)

(available for SS & CAA)

4. MOUNTING

PM Post mounted

WM Wall or guard rail mounted

5. INFILL

STC Stainless steel cable

GL Glass (provided by others)

CX Custom

NR Not required

6. LIGHT DISTRIBUTION

10 10 Degree

45 45 Degree

65 65 Degree

NI Handrail only (not illuminated)

7. LIGHT COLOR

27K Warm White

3K Warm White

5K Cool White

27KH OWarm White 3KHO Warm White

5KHO Cool White

R Red

G Green

B Blue

A Amber

8. LENGTH

9. VOLTAGE / DIMMING

1 120v

2 277v

3 120v w/dim

4 277v w/dim

5 Other

10. SPECIFY DRIVER /

DIMMING

2. Each handrail application will be custom to accommodate varying field conditions and

design requirements. Shop drawings will be required to manage specifics of each handrail section.

3. White light variance between LEDs within a single fxture will not exceed ANSI Binning Standards.

4. Only available in 7.6 w/ft.

5. Stainless Steel cable available for flat surfaces only.

6. Detailed elevation drawings of handrail section are required for quote.

7. grab bars available in aluminum only.

(7)

(4)

(4)

(4)

(4)

(3)

(3)

(3)

(3)

(5)

Please contact factory for correct driver options

1. Driver specification should be reviewd in detail with factory

eB2 2’ nominal bareB3 3’ nominal bar eB4 4’ nominal bareB5 5’ nominal bar

ORDERING:

PREPARED BY: JOB NAME:

CATALOG NUMBER: TYPE:

lum

ara

il

eLumaRail Pg 4.