www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 1 of 39
EMC TEST REPORT
Test report No: EMC-CE-1338
Type of Equipment : CCTV CAMERA
Model Name: HD61X Variant Model Name: HD73X, CNB-D2750PVR, CNB-V1760PVR Applicant: CNB Technology Inc. Manufacturer #1: CNB Technology Inc. Manufacturer #2: CNB Electronic (shenzhen) Co., Ltd
Test standards : EN 55022:2006, Class A EN 50130-4:1995+A1:1998+A2:2003 Testing Laboratory : EMC Compliance Ltd.
Test result : Complied
This product complies with the requirements of the EMC Directive 2004/108/EC. The results in this report apply only to the sample tested. This test report shall not be reproduced except in full, without the written approval of EMC compliance Laboratory. Receipt date: 2008. 05.06 Date of testing: 2008. 05.14 ~ 05.16 Issued date: 2008. 05.20
Tested by: Approved by: PARK, YONG-JIN CHUNG, MIN-SEOK
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 2 of 39
Contents
1. Applicant information .....................................................................................................................3
2. Laboratory information ...................................................................................................................4
3. Test system configuration ..............................................................................................................5
3.1 Operation environment .............................................................................................. 5
3.2 Measurement Uncertainty ....................................................................................... 6
4. Description of E.U.T.........................................................................................................................7
4.1 General information................................................................................................... 7
4.2 Product description ................................................................................................... 7
4.3 Auxiliary equipments ................................................................................................. 8
4.4 Test configuration..................................................................................................... 8
4.5 Operating conditions ................................................................................................. 9
5. Summary of test results................................................................................................................10
5.1 Modification to the E.U.T.......................................................................................... 10
5.2 Summary of EMI emission test results ..................................................................... 10
5.3 Summary of immunity test results ........................................................................... 10
5.4 Performance criteria................................................................................................ 11
6. Test results.....................................................................................................................................13
6.1 Radiated Emission .................................................................................................. 13
6.2 Electrostatic Discharge test result ............................................................................ 18
6.3 Radio Frequency Electromagnetic Fields ................................................................. 22
6.4 Electric Fast Transient/BURST ................................................................................ 24
6.5 Surge ..................................................................................................................... 27
6.6 Conducted Immunity ............................................................................................... 30
7. E.U.T. photographs ................................................................................................................ 33
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 3 of 39
1. Applicant information Applicant : CNB Technology Inc. Address : #701,star valley,60-11 Gasan-Dong, Geumcheon-Gu, Seoul,153-777, Korea Telephone : +82-2-2109-1498 Fax. : +82-2-2109-1440 E-mail : [email protected] Contact name : LEE KI SUNG
Manufacturer#1 : CNB Technology Inc. Address : #701,star valley,60-11 Gasan-Dong, Geumcheon-Gu, Seoul,153-777, Korea Telephone : +82-2-2109-1498 Fax. : +82-2-2109-1440 E-mail : [email protected] Contact name : LEE KI SUNG Manufacturer#2 : CNB Electronic (Shenzhen) co., Ltd Address : 4~5/F.,4 Bldg kingwingtat technology industry Park gangtou village, buji town, long gang district Shenzhen,p.r.china Telephone : 0755-8974 6000-100 Fax. : 0775-8974 8321
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 4 of 39
2. Laboratory information Address EMC compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea Telephone Number : 82 31 336 9919 Facsimile Number : 82 31 336 4767 CBTL Testing Laboratory FCC Filing No.: 793334 FCC CAB.: KR0040 VCCI Registration No. : C-1713, R-2710, T-258 KOLAS NO.: 231 SITE MAP
EMC compliance
Yongin city
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 5 of 39
3. Test system configuration
3.1 Operation environment Temperature Humidity Pressure
OATS : 19 °C 40 % - Immunity area : 20 °C 41 % 1000 hPa Test site These testing items were performed following locations; Semi-anechoic chamber: Radiated Emission #4(3m) OATS : Radiated Emission (10m) Anechoic chamber (3m) : RS Immunity area :, ESD, EFT/Burst, Surge, CS
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 6 of 39
3.2 Measurement Uncertainty All measurements involve certain levels of uncertainties, especially in field of EMC. The factors contributing to uncertainties are test receiver, cable loss, antenna factor calibration, Antenna directivity, antenna factor variation with height, antenna phase center variation, antenna frequency interpolation, measurement distance variation, site imperfection, mismatch, and system repeatability. Based on NIS 80, 81, the measurement uncertainty level with a 95% confidence level was applied. Radiated Emission measurement :(k=2, 95%) 30-300 MHz ; 3 m: ±3.73 [dB], 10 m: ±3.71 [dB] 300-1000 MHz ; 3 m: ±3.81 [dB], 10 m: ±3.80 [dB]
Radio Frequency Electromagnetic Fields :(k=2, 95%) ± 1.0556 [dB]
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 7 of 39
4. Description of E.U.T. 4.1 General information
- HD61X is a CCTV camera.
4.2 Product description
Type of product: CCTV CAMERA
Model name (Basic): HD61X
Model name (Variant): HD73X, CNB-D2750PVR, CNB-V1760PVR
Difference: HD73X: High Resolution CNB-D2750PVR: CNB BRAND of HD61X CNB-V1760PVR: CNB BRAND of HD73X
Serial no: -
Trade name : -
Testing Voltage: DC 12V
Product rating: DC 12V
Note : This test was done with HD61X.
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 8 of 39
4.3 Auxiliary equipments
Type Model / Part # Serial number Manufacturer
Monitor CX911MW N732H1IL900530W SAMSUNG
DC power supply 6032A US38322201 HP
4.4 Test configuration
Powersupply
EUT
Monitor
BNC cable(*2)
DC12V
(*1 )
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 9 of 39
Type Description Connection (To) Spec. Length(m) Note *
Power Power supply (DC 12V) Non-Shield 3.0 1
Signal BNC cable Monitor Shield 3.0 2
4.5 Operating conditions The EUT was configured as normal intended use.
Test mode Normal operating 1 Display mode.
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 10 of 39
5. Summary of test results
5.1 Modification to the E.U.T.
None
5.2 Summary of EMI emission test results
Application Test method Test result
Conducted emission EN 55022 Class A N/A
Radiated emission EN 55022 Class A Complied Harmonics current EN 61000-3-2:2006 N/A Voltage fluctuations and flickers EN 61000-3-3:2005 N/A
5.3 Summary of immunity test results
Items Application Test method Test resultElectrostatic discharge Enclosure EN 610004-2:1995+A1+A2:2001 Complied
Radiated RF immunity Enclosure EN 61000-4-3:1995+A1:2002 Complied
Fast transient DC 12V Signal EN 61000-4-4:1995+A1+A2:2004 Complied
Surge DC 12V Signal EN 61000-4-5:1995+A1:2001 Complied
Conducted RF immunity
DC 12V Signal EN 61000-4-6:1996+A1:2001 Complied
Magnetic field immunity Enclosure EN 61000-4-8:1994+A1:2001 N/A
Voltage dip/interruption DC 12V EN 61000-4-11:2004 N/A
Voltage variation DC 12V EN 50130-4:2003 N/A
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 11 of 39
5.4 Performance criteria The variety and the diversity of the apparatus within the scope of this document makes it difficult to define precise criteria for the evaluation of the immunity test results. If as a result of the application of the tests defined in this standard, the apparatus becomes dangerous or unsafe then the apparatus shall be deemed to have failed the test. A functional description and a definition of performance by the manufacture and noted in the test report, based on the following criteria: Electrostatic discharge There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing which could be interpreted by associated equipment as a change, Radiated electromagnetic fields There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing which could be interpreted by associated equipment as a change, and no such Flickering of indicators occurs at a field strength of 3V/m. For components of CCTV systems, where the picture is allowed at 10V/m, providing.
(a) there is no permanent damage or change to EUT (e.g. no corruption of memory or changes to programmable setting etc.) (b) at 3V/m, any deterioration of the picture is so minor that the system could still be
used; and (c) there is no observable deterioration of the picture at 1V/m.
Fast transient burst / slow high energy voltage surge There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing That there is no residual is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change, and no such flickering of indicators oeuvres at U=130dBuV. For components of CCTV systems, where the status is monitored by observing the TV picture, then deterioration of the picture is allowed at U=140dBuV, providing:
(a) there is no permanent damage or change to the EUT (e.g. no corruption of memory or changes to programmable settings etc.):
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 12 of 39
(b) at U =130dBuV, any deterioration of the picture is so minor that the system could still be used; and
(c) there in no observable deterioration of the picture at U +120dBuV. Conducted RF immunity There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing That there is no residual is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change, and no such flickering of indicators oeuvres at U=130DBuv. For component of CCTV systems, where the status is monitored by observing the TV picture, then deterioration of the picture is allowed at U=140dBuV, providing:
(d) there is no permanent damage or change to the EUT (e.g. no corruption of memory or changes to programmable settings etc.):
(e) at U =130dBuV, any deterioration of the picture is so minor that the system could still be used; and
(f) there in no observable deterioration of the picture at U +120dBuV. Voltage dip/interruption There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the conditioning is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change. The EUT shall meet the acceptance criteria for the functional test, after the conditioning.
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 13 of 39
6. Test results 6.1 Radiated Emission
Test specification EN 55022 Sections 6, Class A
Test mode Display mode.
Date 2008.05.15
Power supply DC 12V
Test facility Semi-anechoic chamber #4, 10m OATS
Temperature (°C) 18 °C Humidity (%) 39 %
Remarks Complied Minimum limit margin is 1.00 dB at 85.13 MHz.
6.1.1 Limits of radiated emission measurement
Frequency [MHz] Class A(dBuV/m)@10m Class B(dBuV/m)@10m
30-230 40 30 230-1000 47 37
Above 1000MHz
6.1.2 Measurement procedure A pretest was performed at 3m distance in a semi-anechoic chamber for searching correct frequency. The final test was done at a 10m open area test site with a quasi-peak detector. EUT was placed on a non-metallic table height of 0.8m above the reference ground plane. Cables were folded back and forth forming a bundle 0.3m to 0.4m long and were hanged at a 0.4m height to the ground plane. Cables connected to EUT were fixed to cause maximum emission. Test was made with the antenna positioned in both the horizontal and vertical planes of polarization. The measurement antenna was varied in height above the conducting ground plane to obtain the maximum signal strength.
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 14 of 39
6.1.3 Used equipments
Equipment Model no. Serial no. Makers Next cal. date Used
Test Receiver ESCI 100001 R&S 08.11.16 TRILOG SUPER
BROADBAND ANT VULB9160 3228 Schwarz beck 10.02.21
Antenna Mast A109 N/A DAEIL - Turn Table TS25 N/A DAEIL - 10m OATS - - EMC Compliance -
6.1.4 Sample calculation The field strength is calculated adding the antenna Factor, cable loss and, Antenna pad adding, subtracting the amplifier gain from the measured reading. The sample calculation is as follow: FS = MR + AF + CL + AT -AG MR = Meter Reading AF = Antenna Factor CL = Cable Loss AP = Antenna Pad AG=Amplifier Gain If MR is 30dB, AF 12dB, CL 5dB, AP 10dB, AG 35dB The result (MR) is 30 + 12 + 5 + 10 –35 = 22dBuV/m
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 15 of 39
6.1.5 Photographs of test setup
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 16 of 39
6.1.6 Radiated emission measurement result
*3m Semi-anechoic chamber Pre-scan Data ( #4) -Horizontal
-Vertical
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 17 of 39
*10m OATS measurement data
Reading Pol.
[MHz] [dBuV/m] [m] Antenna Cable [dBuV/m] [dBuV/m] [dB]85.13 28.6 V 2.4 141 8.30 2.10 40.0 39.00 1.00
141.88 10.1 V 1.6 109 12.77 2.57 40.0 25.44 14.56198.63 20.2 H 1.0 344 9.46 3.07 40.0 32.72 7.28198.63 24.0 V 1.0 120 9.46 3.07 40.0 36.52 3.48225.45 17.0 H 4.0 327 10.24 3.17 40.0 30.43 9.57255.36 25.2 V 2.1 162 11.36 3.45 47.0 40.02 6.98255.38 22.9 H 3.6 296 11.36 3.45 47.0 37.71 9.29425.63 18.1 H 2.0 338 15.59 4.52 47.0 38.21 8.79
MarginLimits ResultFrequency Height CorrectionFactorangle
* Note : Reading = Test Receiver value,
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 18 of 39
6.2 Electrostatic Discharge test result
Test specification EN61000-4-2:2001
Test level Contact: ± 2, 4, 6 kV Air: ± 2, 4, 8 kV HCP / VCP : ± 2, 4, 6 kV
Discharge impedance 330 Ω/150
Power supply DC 12V
Date 2008.05.16
Number of discharge 10 Interval between discharges : ≥ 1s
Temperature(°C) 20°C Humidity (%) 41% Pressure (mb) 1000 mb
Remarks
Complied - There was no change of operation status during above testing.(A1) - During the test, some of flickering phenomenon happened. After this test, EUT was operated normally.(C1, A2)
6.2.1 Measurement procedure A ground reference plane was located on the floor, and connected to earth via a low Impedance connection. The return cable of the ESD generator was connected to the reference plane. In case of floor standing equipment, EUT was placed on the reference plane on 0.1 m of insulating Support. In case of table top equipment, EUT was placed on a wooden table 0.8m above the reference grounded floor. A horizontal coupling plane(HCP) was placed on the table, and Connected to the reference plane via a 470 resistor located in each end (0.5mm insulating support between EUT and HCP). In both cases a vertical coupling plane(VCP) OF 0.5 X 0.5m was located 10cm from the EUT’s sides. The VCP was connected to the reference plane in the same matter as the HCP.
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 19 of 39
6.2.2 Used equipments
Equipment Model No. Serial No. Makers Next Cal. Date Used
ESD Tester PESD 1600 H011 309 HAEFELY 08.06.26
HCP - - - -
VCP - - - -
6.2.3 Photographs of test setup
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 20 of 39
6.2.4 Measurement result Electrostatic Discharge (Test Point)
Air discharge
Contact discharge
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 21 of 39
Contact discharge Location(EUT) Applied level (±) Result
C1 Screw ±2,4,6KV Complied HCP (All 4 sides) ±2,4,6KV Complied VCP (All 4 sides) ±2,4,6KV Complied
Air discharge
Location(EUT) Applied level(±) Result A1 EUT case ±2,4,8KV Complied A2 Power port ±2,4,8KV Complied
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 22 of 39
6.3 Radio Frequency Electromagnetic Fields
Test specification EN 61000-4-3:2002
Tested frequency 80MHz – 2000MHz log 1% step
Test level & Modulation
1,3,10 Vrms, 80% Amplitude Modulation(1kHz) 1,3,10 Vrms, Pulse Modulation (1Hz (0.5s ON: 0.5 s OFF))
Distance 3m from EUT to tip of antenna
Dwell time 3S
Step size 1% step
Power supply DC 12V
Date 2008.05.14
Temperature(°C) 19°C Humidity (%) 40% Pressure (mb) 1002 mb
Remarks
Complied - There was no change of operation status during above testing.(1V) - During the test, some of flickering phenomenon happened.
After this test, EUT was operated normally.(3V,10V)
6.3.1 Measurement procedure The test was performed at 3m full anechoic chamber. For floor standing equipment, the EUT was standing on the floor. For tabletop equipment, the EUT was located on a wooden table 0.8m above the floor. The EUT was tested all sides, horizontal and vertical polarization. The field uniformity was calibrated for 1V/m, 3V/m, 10V/m.
6.3.2 Used equipments
Equipment Model no. Serial no. Makers Next Cal. date Used
Power meter PM2002 302852 AR 09.05.08 Power sensor (with adapter) PH2000 303224 AR 09.05.08
Power sensor (with adapter) PH2000 303222 AR 09.05.08
Directional coupler DC6180 303976 AR 09.05.08
Signal generator E4421B GB40052295 AGILENT 08.10.25
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 23 of 39
Amplifier 150W1000M2 303843 AR 09.04.11
Directional Coupler DC7144M1 320279 AR 09.02.19
Amplifier 60S1G3M2 320444 AR 09.04.11
BiconiLog Ant. LPDA-0803 130269 ETS -
BiconiLog Antenna 3142B 1786 EMCO -
Field monitor SI-300 - TDK -
Controller HD 100 - Deisel -
Turn table DS 412S - Deisel -
Antenna mast MA 220 - Deisel -
6.3.3 Photographs of test setup
6.3.4 Measurement result
Location(EUT) Antenna polarization Result
Horizontal Complied Front side Vertical Complied Horizontal Complied Rear side Vertical Complied Horizontal Complied Left side Vertical Complied Horizontal Complied Right side Vertical Complied
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 24 of 39
6.4 Electric Fast Transient/BURST
Test specification EN61000-4-4 : 2004
Coupling DC 12V,Signal: Clamp
Test level DC 12V : ± 1 kV Peak Signal : ± 1 kV Peak
Repetition frequency 5 kHz, Tr/Th = 5/50nS
Coupling time 60s
Power supply DC 12V
Date 2008.05.16
Temperature(°C) 20°C Humidity (%) 41% Pressure (mb) 1002 mb
Remarks Complied - During the test, some of flickering phenomenon happened.
After this test, EUT was operated normally.
6.4.1 Measurement procedure A ground reference plane was located on the floor. EFT generator was connected to reference ground plane via low impedance connection. For floor standing equipment, EUT was placed on a 0.1 m wooden table. For tabletop equipment, EUT was placed on a 0.8m above the ground reference plane. Test generator and coupling/decoupling network was placed on, and bounded to, the ground reference plane. When using the coupling clamp, the minimum distance between the coupling plates and all other conductive surfaces, except the ground reference plane beneath the coupling clamp, Shall be 0.5m.
6.4.2 Used equipments
Equipment Model No. Serial No. Makers Next Cal. date Used
Generator UCS 500 M6 V0545100858 EM TEST 09.01.07 Capacitive
Coupling Clamp - - EM TEST -
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 25 of 39
6.4.3 Photographs of test setup
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 26 of 39
6.4.4 Measurement result
DC 12V
EFT coupling point (+) (-) Result L(+) +1KV -1KV Complied N(-) +1KV -1KV Complied L-N +1KV -1KV Complied Signal
EFT coupling point (+) (-) Result BNC cable +1KV -1KV Complied
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 27 of 39
6.5 Surge
Test specification EN 61000-4-5 :2001
Coupling DC 12V
Test level DC 12V: 0.5,1 KV Signal: 0.5,1 KV
Surge pulse shape Tr/Th =1.2/50uS
Coupling Impedance DC12V: 40Ω+0.5 Signal (BNC): Direct
Angles 0°,90°,180°,270°
Number of surge & Coupling time 5T/1min
Power supply DC 12V
Date 2008.05.16
Temperature(°C) 20°C Humidity (%) 41% Pressure (mb) 1001 mb
Remarks Complied - During the test, some of flickering phenomenon happened.
After this test, EUT was operated normally.
6.5.1 Measurement procedure A ground reference plane was located on the floor. SURGE generator was connected to reference ground plane via low impedance connection. For floor standing equipment, EUT was placed on a 0.8 m wooden table. For tabletop equipment, EUT was placed on a wooden table (0.8m) above the reference plane.
6.5.2 Used equipments
Equipment Model No. Serial No. Makers Next Cal. date Used
Generator UCS 500 M6 V0545100858 EM TEST 09.01.07
CDN CNV 508 1001-10 EM TEST -
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 28 of 39
6.5.3 Photographs of test setup
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 29 of 39
6.5.4 Measurement result DC 12V
Coupling point (+) (-) Result L-N +0.5,1KV -0.5,1KV Complied Signal
Coupling point (+) (-) Result BNC cable +0.5,1KV -0.5,1KV Complied
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 30 of 39
6.6 Conducted Immunity
Test specification EN 61000-4-6:2001
Tested frequency 150 KHz – 100 MHz 1% step
Test level & Modulation
1,3,10 Vrms, 80% Amplitude Modulation(1kHz) 1,3,10 Vrms, Pulse Modulation (1Hz (0.5s ON: 0.5 s OFF))
Coupling method DC 12V : M2 Signal : clamp
Step size 1% step
Power supply DC 12V
Date 2008.05.14
Temperature(°C) 19°C Humidity (%) 40% Pressure (mb) 1002 mb
Remarks
Complied - There was no change of operation status during above testing.(1V) - During the test, some of flickering phenomenon happened.
After this test, EUT was operated normally.(3V,10V)
6.6.1 Measurement procedure A ground reference plane was located on the floor. The test was performed on a ground reference plane on a 0.1m wooden table. This test were performed using CDN for mains, clamp for signal and injection probe. The frequency range was swept from 150 kHz to 100MHz.This frequency range was Modulated with 1 kHz sine wave at 80%. The signal generators provided the modulated frequency at a 1% step size. The power and all network cable, I/O cables longer than 3m in length were tested.
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 31 of 39
6.6.2 Used equipments
6.6.3 Photographs of test setup
Equipment Model no. Serial no. Makers Next Cal. date Used
CS generator CWS 500 C S1 V0635101750 EM TEST 08.10.15
CDN CDN M2/M3 0906-12 EM TEST 08.10.06
Attenuator 73-6-34 MU918 MCE/WEINSCHEL 09.02.04
EM Clamp KEMZ 801 17643 Schaffner 09.04.01
EM Clamp KEMA 801 17899 Scahffner -
Current probe MD720 W1345167/M6/0068 Schaffner -
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 32 of 39
6.6.4 Measurement result
Coupling point Coupling method Result Power CDN (M2) Complied
BNC cable Clamp Complied
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 33 of 39
7. E.U.T. photographs Front View
Rear View
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 34 of 39
Inside
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 35 of 39
Main Board
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 36 of 39
Power Board
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 37 of 39
LED Board
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 38 of 39
Lens
www.compliancegroup.com
EMC Compliance Ltd.
82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 39 of 39
SUB Board