EUROFINS PRODUCT SERVICE GMBH
EMC TEST - REPORT
TEST REPORT NUMBER: G0M20904-2307-E-13
Eurofins Product Service GmbH Storkower Str. 38c, 15526 Reichenwalde, Phone +49-33631-888 0 Germany Fax +49-33631-888 660
Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 1 of 4
TABLE OF CONTENTS
1 General Information 2
1.1 Notes 2
1.2 Operator 2
1.3 Testing laboratory 3
1.3.1 Location 3
1.3.2 Details of accreditation status 3
1.3.3 Test location, if different 3
1.4 Details of applicant 4
1.5 Application details 4
1.6 Test item 4
1.6.1 Description of test item 4
1.6.2 Manufacturer (if different from approval holder in point 1.4) 4
1.7 Test standards 4
2 Technical test 5
2.1 Summary of test results 5
2.2 Test environment 5
2.3 Test equipment utilized 6
2.4 Testresults acc. EN 301 489 - 7 /14/ 7
2.4.1 Carried out emission tests 8
2.4.2 Carried out immunity tests 10
2.4.3 Test protocols 14
3 Normative references 19
Annex A: Pictures
Annex B: Diagrams
Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 3 of 6
1.3 Testing laboratory 1.3.1 Location EUROFINS PRODUCT SERVICE GMBH STORKOWER STR. 38c D-15526 REICHENWALDE B. BERLIN GERMANY Telephone : + 49 33631 888-0 Telefax : + 49 33631 888-660 1.3.2 Details of accreditation status DAR ACCREDITED TESTING LABORATORY DAR-REGISTRATION NUMBER: DAT-P-268/08 RECOGNIZED NOTIFIED BODY EMC REGISTRATION NUMBER: BNetzA-bS EMV-07/61 RECOGNIZED NOTIFIED BODY R&TTE REGISTRATION NUMBER: BNetzA-bS-02/51-53 FCC FILED TEST LABORATORY REG.-NO. 96970 A2LA ACCREDITED TESTING LABORATORY CERTIFICATE NO. 1983.01 BLUETOOTH QUALIFICATION TEST FACILITY (BQTF) ACCREDITED BY BLUETOOTH QUALIFICATION REVIEW BOARD INDUSTRY CANADA FILED TEST LABORATORY REG. NO. IC 3470 1.3.3 Test location, if different Name : ./. Street : ./. Town : ./. Country : ./. Telephone : ./. Fax : ./. Email : ./.
Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 4 of 7
1.4 Details of applicant Name : Falcom Wireless Communications GmbH Street : Gewerbering 6 Town : 98704 Langewiesen Country : Germany Telephone : +49 3677 8042-0 Fax : +49 3677 8042-215 Email : [email protected] Contact : Herr Ralf Leipoldt Telephone : +49 3677 8042-0 1.5 Application details Date of receipt of application : 06.04.2009
Date of receipt of test item : 06.04.2009
Date of test : 28.04.2009 1.6 Test item 1.6.1 Description of test item Description of test item : GSM/GPRS/GPS tracking unit
Type identification : FOX-LT-IP
Serial number : without
Voltage supply : 12 / 24 VDC
Operating Mode : GSM-link 1.6.2 Manufacturer (if different from approval holder in point 1.4) Name : --- Street : --- Town : --- Country : --- 1.7 Test standards
EN 301 489-1 V 1.8.1 EN 301 489-7 V 1.3.1
EN 55022: 2006 + A1: 2007
Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 5 of 8
2 Technical test 2.1 Summary of test results No deviations from the technical specification(s) were ascertained in the course of the tests performed. or The deviations as specified in 2.4 were ascertained in the course of the tests performed. 2.2 Test environment Temperature : 24,5 ° C Relative humidity content : 31 % Air pressure : 1005 hPa
Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 6 of 9
2.3 Test equipment utilized
No. Test Equipmen Type Manufacturer ETS 0001 ESD Gun SESD 30000 Schlöder ETS 0008 Antenna Loop antenna Siemens ETS 0012 Biconical Antenna HK 116 R & S ETS 0013 LPD Antenna HL 223 R & S ETS 0014 Log Periodical Antenna HL 025 R & S ETS 0038 RF amplifier 150L Amplifier Research ETS 0032 Controller HD 050 Heinrich Deisel ETS 0039 Absorbing clamp MDS 21 R & S ETS 0040 Artificial Mains Network ESH3-Z5 R & S ETS 0041 T-Artificial Mains Network ESH3-Z4 R & S ETS 0042 Artificial Mains ESH3-Z6 R & S ETS 0045 Vehicle LISN NNBM 8126D Schwarzbeck ETS 0052 Audio analyzer UPA 4 R & S ETS 0056 Ultra Compact Simulator UCS 500 M4 EM Test ETS 0057 Motor Variac MV 2616 EM Test ETS 0058 Capacitive coupling clamp E 502 B Keytek/ EMC ETS 0059 Kikusui amplifier PCR 2000L Keytek/ EMC ETS 0064 CDN IEC 61000-4-6 Keytek/ EMC ETS 0066 EM Injection Clamp FCC/ EMC ETS 0076 Feeding bridge A SBA 1000 ESP ETS 0082 PC system Esotronic ETS 0085 Shielded room SR 1 Frankonia ETS 0086 Semi-Anechoic chamber AC 1 Frankonia ETS 0088 Color TV pattern Generator PM 5518-TX VPS Philips ETS 0092 Power Amplifier 150W1000 AR Amplifier Research ETS 0102 CDN M3-801/6 MEB ETS 0103 Magnetic field test set MF1000 EMC-Partner ETS 0148 RF Current Probe F-65 FCC ETS 0155 Signal Generator SMG R & S ETS 0157 TV and Sat-Signalgenerator VTG 700 Grundig ETS 0161 Harmonic / Flicker Analyzer HFA 3000 Schlöder ETS 0178 Open area test side 10m ETS ETS 0233 Direction coupler RK 100 MEB ETS 0276 Audio Analyzer UPL 16 R & S ETS 0282 RF bridge 75 Ohm 86207 A HP ETS 0287 EMI Test receiver ESHS10 R & S ETS 0288 Artificial mains ESH2-Z5 R & S ETS 0292 RF Generator SMHU R & S ETS 0348 RF Millivolt meter URV 55 R & S ETS 0300 RF amplifier 75 A 250 Ar ETS 0348 RF Millivolt meter URV 55 R & S ETS 0401 MPEG2 Generator DVG R & S ETS 0402 TV Messender SFQ R & S ETS 0409 Stripline DC220 Schwarzbeck ETS 0428 4-WIRE ISN with B1 ENY41 R & S ETS 0448 RF Power Amplifier AR 60S1G3 AR Amplifier Research ETS 0472 Antenna BTA-H Frankonia ETS 0474 EMI Test Receiver ESCS 30 R&S ETS 0485 Radio Communication Tester CMU 200 R&S
Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 7 of 10
2.4 Testresults acc. EN 301 489 - 7 /14/ 1st test test after modification production test
Test Emission / Immunity Done Test
passed Test failed
EN 301 489-1 /1/ clause 8.3, 8.4, 8.7 Conducted Emission EN 55022 /13/
EN 301 489-1 /1/ clause 8.2 Radiated Emission EN 55022 /13/
EN 301 489-1 /1/ clause 9.3 Electrostatic Discharge EN 61000-4-2 /2/
EN 301 489-1 /1/ clause 9.2 Radiated Immunity EN 61000-4-3 /3/
EN 301 489-1 /1/ clause 9.4 Electrical Fast Transients EN 61000-4-4 /4/
EN 301 489-1 /1/ clause 9.8
Transients comm.& diff. mode EN 61000-4-5 /5/
EN 301 489-1 /1/ clause 9.5 RF continues conducted EN 61000-4-6 /6/
EN 301 489-1 /1/ clause 9.7 Voltage dips and Interruption EN 61000-4-11 /8/
EN 301 489-1 /1/ clause 9.6
Transient and surges in vehiculars
ISO 7637-1 /11/ ISO 7637-2 /12/
Comment:
Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 8 of 11
2.4.1 Carried out emission tests 2.4.1.1 Conducted Emission This test is in accordance to subclause 8.3; 8.4 and 8.7 of EN 301 489-1 /1/. Test Equipment
• ETS 0040 • ETS 0085 • ETS 0474 • Software: ES-K1, Vers. 1.6SP2
Test Procedures • Test configuration The test configuration is contained inside of a shielded chamber and corresponds to the standard EN 55022 /13/. The equipment under test is placed in the facility on a wooden table 0.8 m high. The equipment under test is connected with the artificial mains network (AMN) in a distance of 0,8 m and also 0,8 m from other subassembly and metallic area. The observation of the equipment under test is realized by 3 video cameras and by a microphone. • Test parameters and marginal conditions The test are carried out with a nominal impedance by 50 Ω / 50 μH of the AMN in a frequency range of 150 kHz to 30 MHz. Further information please find in test report. The equipment under test fulfils the requirement in accordance with the criteria of the standard.
Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 9 of 12
80 cmto thegroundtable
80 cm
10 cm
40 cmmin
Conducted Emission according toEN 55022
EUT
AMNAMN
ISN
AE
Non-conductive table
Bonded to horizontal ground planeBonded to horizontal ground
plane
Rear of EUT to flushed with rear of taple top
AMN = Artificial mains networkAE = Associated equipmentEUT = Equipment under testISN = Impedance stabiliyation network
Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 10 of 13
2.4.2 Carried out immunity tests 2.4.2.1 RF Electromagnetic Field This test is in accordance to subclause 9.2 of EN 301 489-1 /1/. Test Equipment
• ETS 0086 • ETS 0155 • ETS 0448 • ETS 0472 • Software: ETS RF-Field v.27.09.2005
Test Procedures • Test configuration The test configuration is contained inside of a shielded chamber and corresponds to the standard EN 61000-4-3 /3/. The equipment under test is placed in the facility on a wooden table 0.8 m high on the centre axis of the chamber. The power supply and the RF connection points are close to the equipment under test at the floor of the chamber inside a connection box. The cables to this connection box are shielded and below the double floor. The transmitting antenna is placed in a height of 1.5m, in a distance of 3.0 m. The RF-generators are placed in a special room adjacent to the chamber. The observation of the equipment under test is realized by 3 video cameras and by a microphone. • Test parameters and marginal conditions The tests are carried out with a field strength by 3 V/m (measured in the unmodulated field) with amplitude modulated signal by a depth of 80 % by a sinusoidal audio signal of 1 kHz. The logarithmic step was 1% and the dwell time was 1s dependent of the EUT cycle time. Further information please find in test protocol. The equipment under test fulfils the requirement in accordance with the criteria of the standard.
Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 11 of 14
RF - Field according to EN 61000 - 4 - 3
Field-generating antenna
Lines > 3 mor not definedIrradiated length has to be 1 m
0,8 m
Absorber elements placed as required in partly covered anechoice chambers to reduce the ground reflexion
Absorber or disturbance filter
Uniform area
Non-conductive table
Lines < 3 mon 1 m total length, low-induction bunched
Real cabling < 1 m
Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 12 of 15
2.4.2.2 Transients and Surges in vehicular enviroment These test are applicable to mobile radio and ancillary equipment intended for use in a vehicular enviroment. This test is in accordance to subclause 9.6 of EN 301 489- 1 /1/. Test equipment
• ETS 0244 • ETS 0245 • ETS 0246 • Software: ISMISO 4.11
Test Procedures • Test configuration The test configuration is in correspondence to the standard ISO 7637 - 1 / - 2 /11/, /12/. The test is carried out on a wooden table with a grounded metal plate on its top. The equipment under test is placed on an insulating support of 100 mm height above this metal plate. • Test parameters and marginal conditions The tests are carried out are the pulses according to subclause 9.6.2.1 and 9.6.2.2 of EN 301 489- 1 /1/ and the special requiremnets of EN 301 489-7 /2/ subclause 7.2.2. The overview please find in the test protocol.
Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 13 of 16
Transients and Surges in vehicular enviroment
ISO 7637
Pulse injection (prinzipe schemata)
Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 14 of 17
2.4.3 Test protocols
Conducted emission 15
RF-Field 16
RF-common mode 17
Transients and Surges in vehicular environment 18
Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 15 of 17
Conducted Emission
Emission
Standard : EN 301 489-1 /1/ (EN 55022 /13/)
Reg. no. : G0M20904-2307-E-13
Model no. : GSM/GPRS/GPS TRACKING UNIT / FOX-LT-IP
Date : 29.04.2009
Class : B
Frequency range Network Passed Failed Number of rechecks
150 kHz - 30 MHz R S 0
Operating Mode: GSM-link Instrumentation uncertainty: Ulab(cond) = 3.8 dB Comment: See attached diagrams.
Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 16 of 17
Radiofrequency Electromagnetic Field Immunity
RF Field
Standard : EN 301 489-1 /1/ subclause 9.2 (EN 61000-4-3 /3/)
Reg. no. : G0M20904-2307-E-13
Model no. : GSM/GPRS/GPS TRACKING UNIT / FOX-LT-IP
Date : 29.04.2009
Test equipment : Anechoic chamber, amplifier: ar, antenna (BTA-H)
Frequency Range Voltage (RMS) Modulation Frequency Opinion
80 - 1000 MHz 3 V/m 1 kHz (80 % AM) A
1400 - 2700 MHz 3 V/m 1 kHz (80 % AM) A
Operating Mode: GSM-link Opinion: A : No loss of performance or function.
B : Temporary loss of function or performance which is self-recoverable.
C : Temporary loss of function or perform, which req. operat. intervention or system reset.
D : Loss of function which is not recoverable. Passed: yes / no
Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 17 of 17
Conducted Immunity
RF - common mode
Standard : EN 301 489-1 /1/ subclause 9.5 (EN 61000-4-6 /6/)
Reg. no. : G0M20904-2307-E-13
Model no. : GSM/GPRS/GPS TRACKING UNIT / FOX-LT-IP
Date : 29.04.2009
Test port Voltage (rms)
Modulation Frequency Frequency Range Opinion
12 VDC 3 1 kHz 150 kHz - 80 MHz A
24 VDC 3 1 kHz 150 kHz - 80 MHz A
Operating Mode: GSM-link Opinion: A : No loss of performance or function.
B : Temporary loss of function or performance which is self-recoverable.
C : Temporary loss of function or perform, which req. operat. intervention or system reset.
D : Loss of function which is not recoverable.
Passed: yes / no
Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 18 of 18
Transients and surges in vehicular environment
Standard : EN 301 489-1 /1/ subclause 9.6 (ISO 7637-1 /-2 /11/, /12/)
Reg. no. : G0M20904-2307-E-13
Model no. : GSM/GPRS/GPS TRACKING UNIT / FOX-LT-IP
Date : 29.04.2009
Testport Pulse Level ISO 7637-2 Test requirements Criteria
DC-Power line (12V) 1 III 10 times C
DC-Power line (12V) 2a III 10 times A
DC-Power line (12V) 2b III 10 times C
DC-Power line (12V) 3a III 20 minutes A
DC-Power line (12V ) 3b III 20 minutes A
DC-Power line (12V ) 4 III 10 times C
Testport Pulse Level ISO 7637-2 Test requirements Criteria
DC-Power line (24V) 1 III 10 times C
DC-Power line (24V) 2a III 10 times A
DC-Power line (24V) 2b III 10 times C
DC-Power line (24V) 3a III 20 minutes A
DC-Power line (24V ) 3b III 20 minutes A
DC-Power line (24V ) 4 III 10 times C
Opinion: A : No loss of performance or function.
B : Temporary loss of function or performance which is self-recoverable.
C : Temporary loss of function or perform. which req. operat. intervention or system reset.
D : Loss of function which is not recoverable. Passed: yes / no
Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 19 of 19
3 Normative references /1/ EN 301 489-1 V1.8.1 Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements /2/ EN 61000-4-2 : 1995 + A1 : 1998 + A2 : 2001 „Electromagnetic Compatibility (EMC); Part 4: Testing and measurements techniques - Section 2:
Electrostatic discharge immunity test. Basic EMC publication“. /3/ EN 61000-4-3 : 2006 + A1: 2008 „Electromagnetic Compatibility - Basic immunity standard - Radiated, radio-frequency
electromagnetic field. Immunity test“. /4/ EN 61000-4-4 : 2004 „Electromagnetic Compatibility (EMC); Part 4: Testing and measurements techniques - Section 4:
Electrical fast transient/burst immunity test. Basic EMC publication“. /5/ EN 61000-4-5 : 2007 „Electromagnetic Compatibility - Basic immunity standard. Surge immunity Test“. /6/ EN 61000-4-6 : 2007 „Electromagnetic Compatibility - Basic immunity standard - Conducted disturbances induced by
radio-frequency fields. Immunity test. /7/ EN 61000-4-8: 1993 + A1: 2001 „Electromagnetic Compatibility - Testing and measurements techniques Power frequency magnetic field immunity test”. /8/ EN 61000-4-11: 2004
„Electromagnetic Compatibility (EMC); Part 4: Testing and measurements techniques - Section 11: Voltage dips, short interruptions and voltage variations immunity tests - Basic EMC publication“.
/11/ ISO 7637-1 : 2002 „Road vehicles - Electrical disturbance by conducting and coupling Part 1: Definitions and general /12/ ISO 7637-2 : 2004 + A1: 2008 „Road vehicles - Electrical disturbance by conducting and coupling Part 2: Vehicles with nominal 12V or 24V supply voltage – Electrical transient conduction along supply lines only /13/ EN 55022 : 2006 + A1: 2007 „Limits and methods of measurement of radio interference characteristics of information technology
equipment“. /14/ EN 301 489-7 : V1.3.1 Specific conditions for mobile and portable radio and ancillary equipment of digital cellular
radio telecommunications systems (GSM and DCS)
Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany Annex A Page 1 of 1
Annex A: Pictures
EMI voltage test in the dc-mains according to EN 55022
ORDER NO: G0M20904-2307Approval Holder: Falcom Wireless Communication GmbHEUT: GSM/GPRS/GPS-tracking unitModel: FOX-LT-IPTest Site / Operator: Eurofins Product Service GmbH / Mr. KleinTest Conditions: Tnom: 23°C, Unom: 13.5 VDCTest Specification: V-Network: ESH3-Z5 (L)Comment 1: mode: GSM1900 linkComment 2: mode:
-20
-10
0
10
20
30
40
50
60
70
Level [dBµV]
150k 300k 500k 700k 1M 2M 3M 4M 6M 10M 30MFrequency [Hz]
MES EN 55022 Vdc_pre PK MES EN 55022 Vdc_pre AV LIM EN 55022 V QP Voltage QP LimitLIM EN 55022 V AV Voltage AV Limit
Page 1/1 28.04.2009 09:36 EN 55022 Vdc
Annex B Page 1/4
EMI voltage test in the dc-mains according to EN 55022
ORDER NO: G0M20904-2307Approval Holder: Falcom Wireless Communication GmbHEUT: GSM/GPRS/GPS-tracking unitModel: FOX-LT-IPTest Site / Operator: Eurofins Product Service GmbH / Mr. KleinTest Conditions: Tnom: 23°C, Unom: 13.5 VDCTest Specification: V-Network: ESH3-Z5 (N)Comment 1: mode: GSM1900 linkComment 2: mode:
-20
-10
0
10
20
30
40
50
60
70
Level [dBµV]
150k 300k 500k 700k 1M 2M 3M 4M 6M 10M 30MFrequency [Hz]
MES EN 55022 Vdc_pre PK MES EN 55022 Vdc_pre AV LIM EN 55022 V QP Voltage QP LimitLIM EN 55022 V AV Voltage AV Limit
Page 1/1 28.04.2009 09:24 EN 55022 Vdc
Annex B Page 2/4
EMI voltage test in the dc-mains according to EN 55022
ORDER NO: G0M20904-2307Approval Holder: Falcom Wireless Communication GmbHEUT: GSM/GPRS/GPS-tracking unitModel: FOX-LT-IPTest Site / Operator: Eurofins Product Service GmbH / Mr. KleinTest Conditions: Tnom: 23°C, Unom: 27 VDCTest Specification: V-Network: ESH3-Z5 (L)Comment 1: mode: GSM1900 linkComment 2: mode:
-20
-10
0
10
20
30
40
50
60
70
Level [dBµV]
150k 300k 500k 700k 1M 2M 3M 4M 6M 10M 30MFrequency [Hz]
MES EN 55022 Vdc_pre PK MES EN 55022 Vdc_pre AV LIM EN 55022 V QP Voltage QP LimitLIM EN 55022 V AV Voltage AV Limit
Page 1/1 28.04.2009 10:00 EN 55022 Vdc
Annex B Page 3/4
EMI voltage test in the dc-mains according to EN 55022
ORDER NO: G0M20904-2307Approval Holder: Falcom Wireless Communication GmbHEUT: GSM/GPRS/GPS-tracking unitModel: FOX-LT-IPTest Site / Operator: Eurofins Product Service GmbH / Mr. KleinTest Conditions: Tnom: 23°C, Unom: 27 VDCTest Specification: V-Network: ESH3-Z5 (N)Comment 1: mode: GSM1900 linkComment 2: mode:
-20
-10
0
10
20
30
40
50
60
70
Level [dBµV]
150k 300k 500k 700k 1M 2M 3M 4M 6M 10M 30MFrequency [Hz]
MES EN 55022 Vdc_pre PK MES EN 55022 Vdc_pre AV LIM EN 55022 V QP Voltage QP LimitLIM EN 55022 V AV Voltage AV Limit
Page 1/1 28.04.2009 09:49 EN 55022 Vdc
Annex B Page 4/4