40
EMCO ELECTRONICS EMCO ELECTRONICS Welcomes You Welcomes You

Emco Presentation 2Panel Cutout : 90 x 90 mm: 90 x 48 mm for EE601-S! Options Π4-20mA Output with 100E termination Resistance for SCADA Π4-20mA Input instead of 3 wires resistance

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • EMCO ELECTRONICSEMCO ELECTRONICSWelcomes YouWelcomes You

  • CompanyCompanyEmco Electronics established in 1973 initially as an R&D outfit

    progressively grew into a full fledged manufacturing and marketing organisation. It started off by manufacturing Test Measurement & Control devices & Instruments which activity has today become our companys CORE COMPETENCY. In fact, the CORE strength accumulated by the company over last so many years has enabled EMCO ELECTRONICS to enter into new lines of business like agency activity & establishment of PCBs Test & Repair Center.

    Emco Electronics is an ISO 9001:2008 certified Company. The Factory is located at Vasai (Thane Dist.) with Head Office at Lower Parel (Mumbai).

    A Branch office at Bangalore enhances sales & service support tothe Southern Region.

  • Present ActivitiesPresent Activities

    Manufacturing

    PCB Repairs

    Marketing

  • ManufacturingManufacturingThe Company manufactures products for the Transformer Industry like

    ! Automatic Voltage Regulating Relays (AVRs) :for controlling voltage of power transformers

    ! Tap Position Indicators (TPIs) :for indicating the current Tap position of the Power Transformer

    ! Remote Oil/Winding Temperature Indicators (ROTI/RWTI) :for indicating Oil/Winding temperature of Transformer on Remote Panel

    ! Parallel Control Unit (PCU) :for controlling 2 Transformers in Parallel

    ! Voltage Controller Control Unit (VCCU) :for Servo Voltage Stabilizers

    ! Transmitters :for transmitting Tap No./OTI/WTI temperature in terms of 4-20 mA output

    for remote SCADA display! Transformer Temperature Controller (TTC) :

    for Dry type Transformers! Current Converter Unit with Repeater

  • PCB RepairsPCB Repairs

    PCB Test & Repair Centre, located in the heart of Bombay City ( Lower Parel ) can today be claimed as one of India's best equipped and modern Hi-tech DIAGNOSTIC & REPAIR Centres of it's kind. The centre , well equipped in terms of qualified personnel & sophisticated ATEs (Automated Test Equipment) from world's best manufacturers is today ready to take any kind of challenge to repair the most complex PCBs.

    We specialize in repairs of PCBs of Analytical Instruments, like Gas Chromatographs, Spectrophotometers, HPLCs, .. etc.

    We are one of the regular vendors for repairing PCBs of Defense Equipments.

  • R&D CenterR&D Center

    ! R&D Center is recognized by the Dept. of Science & Technology of Govt. of India since 1974

    ! All the products manufactured at Emco Electronics are developed in-house and meet the Quality Standards as required by the Customers

  • Quality PolicyQuality Policy

    Quality at EMCO ELECTRONICS means every individual needs to correctly understand Customer Requirements, both for Internal and External Customers, for ensuring Total Customer Satisfaction at an Optimum Cost, through Continual Improvement

  • ISO CertificateISO Certificate

    EMCOELECTRONICS

    an ISO 9001:2008

    Certified Company

  • ProductsProducts

  • !EE301-M : Regular Model!EE301-T : Integrated Model with Built-in TPI!EE302 : Microcontroller based Model!EE303 : Microcontroller based Model with TPI!EE301-E : Economy Model

    AUTOMATIC VOLTAGE REGULATING AUTOMATIC VOLTAGE REGULATING RELAYSRELAYS

  • Block Diagram of AVRBlock Diagram of AVR

  • AVR EE 301AVR EE 301--EE

    ! Digital Readout for PT Supply and Dead-Band Settings

    ! LED Indicators for Raise, Lower Pre-Signals and Undervoltage and Relay Operation Condition

    ! Continuously adjustable Time Delay Setting! Automatic Resetting after voltage correction! Single Pulse or Continuous pulse Operation of

    Control Relays! Undervoltage Internal Blocking

  • EE-301E Wiring Diagram

    7654321

    987654321

    Aux I/P PT I/P RCom

    L UV

  • AVR EE 301AVR EE 301--MM! Modular Design! Separate Nominal Value and Bandwidth Settings! Continuously adjustable Time Delay setting! Undervoltage Alarm contacts with Internal Blocking! Test mode for testing AVR on Panel! Options :

    Line Drop Compensation Normally Closed Auxiliary Supply fail Relay Contacts Normally Open Control Fail Relay Contacts User defined settings for PT. Supply, Time delay and Under

    voltage Blocking. 4-20mA I/P for Remote Control of NVA

  • AVR EE 301AVR EE 301--TT! Separate Nominal Value and Bandwidth Settings! Continuously adjustable Time Delay setting! Undervoltage Alarm contacts with Internal Blocking! Built-in TPI for maximum 35 Taps, 1K step

    resistance with optional 4-20mA O/P! Control Fail Relay (CFR) available as Standard feature! Overvoltage Blocking at 132V & Restoration at 127 V! Combined UV/OV Relay contacts for Blocking.! Test Mode for testing AVR on Panel options : LDR, AFR

  • EE-301M, EE-301T Wiring Diagram

    Aux I/P PT I/P CT I/P AFR LR

    16151413121110987654321

    RR UV CFR

    2120191817

    Max 4-20mA O/P

    (optional)

    (only for EE-301T)

    Com Min

  • AVR EEAVR EE--302302! Microcontroller based Architecture with Analog/Digital Converter! Keyboard entry for Parameter Settings! Linear or Inverse Time Response! Two independent timers for first and subsequent pulses! Single Pulse or Continuous Pulse Operation! Load Shedding at 3%, 6% and 9%! Readout of Prim. and Sec. Voltages in KV, Volts and % Deviation! Independent Lower and Raise settings in % of Nominal Value! High Speed return action for Overvoltage Condition

    ! Options Line Drop Compensation Normally closed Auxiliary Supply Fail Relay Contacts Built-in Tap Position Indicator upto maximum 35 taps with 1K step Res. Overcurrent Blocking @ 150 % of rated current with a pair of NO contacts

  • 1413121110987654321

    2827262524232221201918171615

    Aux I/P

    PT I/P

    Aux FilO/P

    LR

    CT I/P

    RR OV UV CFR AFR Max

    LS3

    LS6

    LS9

    Com

    TPI com

    Min

    TPI

    EE-302 Wiring Diagram

  • AVR EEAVR EE--303303! Microcontroller based Architecture with Analog/Digital Converter! Keyboard entry for Parameter Settings! Linear or Inverse Time Response! Two independent timers for first and subsequent pulses! Single Pulse or Continuous Pulse Operation! Readout of Prim. and Sec. Voltages in KV and Volts! Independent Lower and Raise settings in % of Nominal Value! Built-in Tap Position Indicator upto maximum 35 taps with 4-20mA O/P! In Manual mode, Taps can be Raised or Lowered via Keyboard! Test mode for testing of AVR operations for all conditions! Min PT, Max PT and Tap Change Count recording! Remote AVR Disable through Potential free contacts with Remote Indications! Overvoltage Blocking action as per the set value

    ! Options Normally closed Auxiliary Supply Fail Relay Contacts PT display of 433V instead of 110V

  • 1413121110987654321

    262524232221201918171615

    Aux I/P

    PT I/P

    LR UV

    OV 4-20 mA O/P

    CFR AFR

    Max

    Com

    com Min

    EE-303 Wiring Diagram

    RR A/M

    TPI

    DisI/P

    TcpI/P

  • ! EE601 : Standard Model! EE601-S : Small Model! EE601-G : TPI with Grey Code Input! EE604 : TPI with Counter! EE605 : TPI with Voltage Display! EE606 : TPI with Dual Polarity! EE607 : TPI with BCD Input! Optional 4-20mA I/p & O/p available

    TAP POSITION INDICATORSTAP POSITION INDICATORS

  • TPI Block DiagramTPI Block Diagram

  • 654321

    0V 110V 230V Max Wip Min

    4321

    Dual 4 -20 mA O/P

    + - + -

    TPI GENERAL Wiring Diagram

  • General Specifications of TPIGeneral Specifications of TPIModel EEModel EE--601601

    ! No. of Taps : 35! Step Resistance : 1K or User defined! Auxiliary Supply : 110/230 V AC ± 10%! Panel Cutout : 90 x 90 mm

    : 90 x 48 mm for EE601-S! Options

    4-20mA Output with 100E termination Resistance for SCADA 4-20mA Input instead of 3 wires resistance chain Suitable for 2 wire Resistor Chain Input Universal Auxiliary Supply from 95V to 260 V AC/DC

  • TPI ModelsTPI Models! EE-604 : Additional 6-digit display for Tap Change

    Counter

    ! EE-605 : Additional 6-digit display for Tap Voltage

    ! EE-606 : Tap No. displayed with Positive or Negative polarity with respect to center position

    ! EE-607 : Tap No. displayed according to 6-digit BCD Input from encoder

    ! EE 601-G : Tap No. displayed according to 5- digit Gray code Input from encoder

  • EE-701 : TRANSMITTER for TPI and ROTI / RWTISuitable for TPI and ROTI/RWTI

    Direct PT-100 Sensor Input available

    Dual 4-20mA O/P

    Din-Rail or Wall Mounting

    Universal Power Supply – 95 to 260 V AC/DC

    EE-602 : Remote Oil/Winding Temperature IndicatorInput Resistance of 0 to 440E / 2.8K/ User defined

    Optional 4-20mA I/P or PT-100 Sensor Input available

    Optional 4-20mA O/P available

    Temperature range of 0oC – 150oC

    Universal Power Supply – 95 to 260 V AC/DC\

    ROTI / RWTI AND TRANSMITTERROTI / RWTI AND TRANSMITTER

  • EE-402 : VCCU for Servo Voltage StabilizersIndependent Settings for Lower, Raise, UV & OV

    Variable Time delay Settings

    LED Indications for Raise, Lower, & Time delay Operations

    Projection Mounting

    VOLTAGE CONTROLLER CONTROL UNITVOLTAGE CONTROLLER CONTROL UNIT

    121110987654321

    230V RR COM LR NO COM NC NO COM NC

    OV UV

    VCCU EE-402 Wiring Diagram

  • ! Microcontroller based architecture with A/D Converter! Selectable Parallel & Independent modes of operation! Built-in Tap Position Indicators for both Transformers ! 4-20 mA output for both Tap Position Indicators! Selectable delay between master and follower pulses! Minimum/Maximum Tap Blocking! Out of step indication with contacts! Automatic control of parallel operation in Master Follower

    mode even in absence of AVR.! Cost effective due to elimination of :

    " Master Follower switches" Wiring from OLTC to Master Follower Switches" Single Panel Requirement" Integrated TPIs with 4-20 mA output for Scada

    Parallel Control UnitParallel Control UnitEEEE--501501

  • ! Monitors and Controls the Winding Temperature of 3 Phase Dry type Transformers

    ! Four Input Channels ! Auto Scan or Hold Mode of operation! Each Channel has programmable Threshold, Delay and Hysteresis! Potential free, 1 C/O relay contacts for Fan, Alarm, Trip and Fault

    Conditions.! Max mode for viewing the maximum temperature reached by each

    channel! Auto Calibration feature for calibrating the unit in field! 4-20 mA output for any one selected channel! Easy to operate user interface using front panel keys

    Transformer Temperature ControllerTransformer Temperature ControllerEEEE--801801

  • Current Converter Unit

    ! Integrated Oil and Winding Temperature Indicator in Single Unit! Monitors and Converts Oil and Winding Temperatures in terms of

    4-20mA DC Current! PT-100 Sensor Input for Oil Temperature and 0-5 Amp Current Input for

    Winding Temperature Indications! 3-Digit 7-Segment LED Displays for OTI and WTI each! Dual 4-20mA DC Current Output for OTI and WTI each

    Repeater! Remote Oil and Winding Temperature indicators in Single Unit! 4-20mA Input for ROTI and RWTI each! CCU and Repeater as a complete set.

    Current Converter Unit with RepeaterCurrent Converter Unit with RepeaterEEEE--608 with EE608 with EE--609609

  • ! Din-Rail Mounting

    ! Maximum upto 35 Taps (or as specified)

    ! 1 KΩ Step Resistance (or as specified)

    ! Automatic Detection of Maximum Tap No.

    ! Automatic Adjustment of 4-20 mA Output

    ! Dual 4-20 mA Output available for Remote Indicators and SCADA

    ! Universal Power Supply (95 260 V AC/DC)

    ! TPI with 4-20 mA Input Feature available (Optional)

    TAP Position IndicatorTAP Position IndicatorEE 601EE 601--WW

  • Export OrdersExport OrdersEmco Electronics products are Exported to International Countries like

    UAE, Oman, Singapore, Brazil, Columbia, Bhutan, Nepal, Australia

    AustraliaDelixi Australia Pty Ltd.Dubai, UAEGulf Radiant Electrical & Trading LLC.BrazilToshiba Do Brazil S.AQatar, ColumbiaSeimens Ltd.Sultanate of OmanOman National Electric Co. (S.A.O.G)NepalNandan Ghee & Oil IndustriesU.A.E.Emirates Transformer & SwitchgearsSultanate of OmanDhofar Power Company S.A.O.G.MalaysiaDOM Industries (M) SDN. BHD DhakaDhaka Electricity Supply AuthorityBhutanBhutan Carbide & Chemicals LtdSingaporeAreva T&D Pte. Ltd

  • Our Our Esteemed Esteemed CustomersCustomers

    All major

    ! Transformer manufacturers! Panel manufacturers! Electricity Boards! Private Power Suppliers

  • Quality Control & AssuranceQuality Control & AssuranceWe at EMCO have been making our very best efforts to establish a

    high standard of Quality and Reliability of our products as may be seen from the various measures adopted by us over a period of time for realizing our goal.

    ! Commitment to accuracy , Reliability, Performance and Services ! Striving towards achieving ZERO DEFECTS / ZERO

    REJECTIONS in the manufacturing process! Raw materials and Accessories of Best Quality! Strict Quality Control at every stage! Excellent workmanship! Rigorous Tests to exacting standards! Latest manufacturing techniques and processes! Continuous development for improving products! Prompt after Sales Service

  • Customer ServiceCustomer Service

    ! Free replacement of unit within Warranty period! Minimal repair cost after Warranty period! Dispatch of repaired unit within 3 days of receipt! Immediate On-Site service when required! Service support on Phone/Email/Fax

  • EMCOEMCO

    representsrepresents

    BharaniBharani ElectronicsElectronics

    Annunciators Buzzers AMF Controllers

    Power Packs

    for

  • AnnunciatorsAnnunciators ....! Manufacturer of Quality Products since 1965! Installation for prestigious clients which include PGCIL, NTPC, NPCIL,

    EIL, NHPC, and all Electricity Boards! Areva, Chennai – Pallavaram unit is using Bharani Annunciators in

    large quantities for last 15 years! Products exported to Saudi Arabia, Srilanka Indonesia, Bangladesh etc.! Unconditional Life Time Guarantee for manufactured products! Most Advanced Micro Controller Single Chip Embedded System! Status Indicators + Watch Dog provided! All sequences of operation as per ISA! In-built push button switches for annunciator functions! Automatic Switching of window colors! Snap fit window frames in 7 different sizes! Universal Operating Voltage! Serial Communication interface (optional)! DC or AC Supply Fail Annunciation (optional)

  • AMF ControllerAMF Controller! Rugged Flush-mounted Unit with Micro Controller Technology! Wide range of Auxiliary Supply : Unit operates between 06 VDC to 35

    VDC ~ continuously variable! Withstands Cranking-Dropout dip upto 0 VDC of Auxiliary Supply upto

    01 second [maximum]! Continuous supervision of Mains [EB] & DG Breaker status, thus ensuring

    human & equipment safety! Internal interlock for Mains & DG Breaker, with LED Indication of

    respective CB status, for fails safe operation! Facility to select : 12V or 24V Battery, with indication & supervision of

    selected Battery Voltage status! Two spare Terminals for connecting external (Aux. Input) Faults! LED Fault Annunciation for : Start Fail, LLOP, High Engine Temp.,

    Engine Fault, Low Battery, Aux. Faults 1 & 2! Front Panel Keypad Switches provided for : Auto, Accept, Manual

    ON/OFF & Emergency STOP! Unit has two major modes of Operation ~ viz : Configuration Mode and

    Run Mode

  • Power PacksPower Packs! Adequate DC energy for energizing trip &

    close coils of Breakers! Built-in Capacitors to store energy on failure of AC Supply! Trip supply healthy indication by LED (Optional)! Can be used as Capacitor Trip Device in unmanned substation

    BuzzerBuzzer! Sounds upto 4 different Tones simultaneously (Spaced Out/

    One-after-Other) when all alarms in a Panel occur simultaneously! Hence, one buzzer sufficient to sound all audible alarms in a panel! User saves cost and need for multiple buzzers! True Multi-Tone and All-in-One Buzzer! Available in One tone unit to Four tone unit

    ! Universal Operating Voltage between 30V to 300V! Hi-Volume dB Output compared to conventional Buzzers

  • Thank You