C O N T R O L S
CAT® CONTROL PANELSElectromechanical
EMCP II
EMCP II+
EMCP II+P
Switchgear Conversion
The Caterpillar family of control panels providesbasic to complete generator set monitoring.Control panels use a standard mounting andwire harness and are easily upgraded to thenext higher specification. The ElectronicModular Control Panels (EMCP II, EMCP II+,and EMCP II+P) are compatible with a completeline of local or remote annunciators, and withremote communication and expansion modules.
PANEL DESCRIPTIONELECTROMECHANICAL
This manual or auto start/stop electromechanicalpanel, equipped with analog gauges, providesbasic generator set metering, engine monitoringand protection, indicator lights, and emergencystop shutdown. Optional protective and controldevices are available.
EMCP II, II+, AND II+P
The EMCP II, II+ and II+P, equipped with high-techelectronics and digital LCD readouts, providethe most complete generator set monitoring,metering, control, and indication. A full rangeof optional protective devices, controls, andlocal and remote annunciators are available.The EMCP II, II+ or II+P may be used for remotegenerator set monitoring and control via a directconnection or modem. The EMCP II, II+ andII+P use environmentally sealed, solid state,microprocessor-based modules.
SWITCHGEAR CONVERSION
The switchgear conversion (SGC) panel providesbasic engine monitoring, protection, and control.It is equipped with a digital LCD display, electronicgauges, and indicator lights. The panel isdesigned to interface with switchgear or remotemounted controls. Optional protection andcontrol devices are available.
Switchgear Conversion
EMCP II and EMCP II+
W H E R E T H E W O R L D T U R N S F O R P O W E R
Electromechanical
EMCP II+P
LEHX9295-02
Common Design EMCP II
C O N T R O L S
CONTROL PANEL FEATURESElectromechanical Panels EMCP Panels
Switchgear(all gauges are analog) (all gauges are digital)Conversion
PGS 225-400 PGS 225-2250 PGS 450-900F (digital gauges)
Switchgear Auto II II+ II+PPGS 450-2250
Generator Metering
Voltmeter — S S S S —Ammeter — S S S S —Phase selector switch — S S S S —Frequency — S S S S —kW — — — S S —kV•AR — — — S S —kV•A — — — S S —Power factor — — — S S —
Generator Set MonitoringDC voltage S S S S S SCoolant temperature S S S S S SOil pressure S S S S S SHours run time S S S S S Srpm S S S S S SOil temperature — — — S(6) S(6) SL/R exhaust manifold temperature — — — S (3500 only) — —
ControlsStart/stop control — Man/Auto Man/Auto Man/Auto Man/Auto Man/AutoEmergency stop control S S S S S SLamp test S S S S S SCycle cranking (adjustable cranking times) S S S S S SVoltage control — S S S S —Cooldown timer — — S S S —Panel lights — — S S S —Load share module (shipped loose) O — O O S(5) OAlarm horn & silence switch — local — O O O S —Frequency control — O O O S —Electronic isochronous governor — O O O S OEther starting aid control — O O O O —Synchronizing control — — — — S —Breaker control — — — — S —
Standard Indicating LightsLow oil pressure shutdown S S S S S SHigh coolant temperature shutdown S S S S S SOverspeed shutdown S(1) S(1) S S S S(1)
Overcrank shutdown S S S S S SEmergency stop shutdown S(1) S(1) S S S S(1)
Generator voltage match — — — — S —Generator frequency match — — — — S —Generator phasing match — — — — S —
Miscellaneous Protective Devices include indicating light select one only select one or several(4) select one onlyOver/under frequency — — — S(2) S(2) —Overcurrent — — — S(2) S(2) —Reverse power — — — S(2) S(2) —Over/under AC voltage — O O S(2) S(2) —Low fuel level O O O O O O(3)
Low coolant level O O O O O OGround (earth) fault — shutdown — O O O O —Generator winding overtemp — prealarm O(3) — O O O O(3)
Generator winding overtemp — shutdown O(3) — O O O O(3)
Generator bearing overtemperature O(3) — O O O O(3)
Low battery voltage — — O O O —
Miscellaneous Controls select one or moreCommon alarm/shutdown volt-free contact S O O O O SOverload relay (kW level) — — — S S —Computer communication data link — — S S S —Integral battery charger – 5 amp (non UL) O O O O O OAutomatic fuel transfer system control O O O O O OJWH/space heater/battery charger disconnect O O O O O OGenerator running volt free contact — O O O O —Remote annunciators (avail. in 8- & 16-light panels) — — O O O —Custom Alarm Module — — O O S —
EnclosureVandal door S S S(7) S(7) S SDust proof (IP52 per IEC 34-5) — — O O O —
Control Panel Features
(1) Combined emergencystop/overspeed light
(2) Common indicating light withseparate diagnostic codes foreach function
(3) Contact only provided —indicating light is not provided
(4) EMCP II, II+, and II+P alarmmodules available in aconfiguration of eight lamps.
(5) Installed in EMCP II+P(6) Except 3300, 3406(7) Not available on 3406C and 3456
S = StandardO = Optional— = not available
www.CAT-ElectricPower.com
©2003 CaterpillarAll rights reserved.
European sourced Printed in U.S.A.
LEHX9295-02 (7-03) Materials and specifications are subject to change without notice.The International System of Units (SI) is used in this publication.