2
Via Naviglio Alto,24/A 43100 PARMA (ITALY) Tel. 0521 772021 Fax 0521 270218 e-mail: [email protected] www.elcos.it GB GE/FO-130906 EMERGENCY AUTOMATIC PANELS FOR GENSET UNITS COMPLETE WITH DISPLAY TO SHOW: instruments 8 : - - - - - total hour meter - partial hour meter - - useful signals for generator set management. mains voltmeter generator voltmeter generator ammeter generator frequency meter battery voltmeter fuel level indicator TYPE LEM-435/32 LEM-430/45 LEM-430/60 45 60 32 58 Three-phase Single-phase Amp (Ac1) FITTING A DIESEL OR GASOLINE ENGINE Three- phase (On request) SIMULTANEOUS READING OF 3 INSTRUMENTS REMOTE SWITCHING MAINS/GENSET AUTOMATIC BATTERY CHARGING (1,5A) AUTOMATIC SUPERVISION OF FAULTS EJP FUNCTION GLOW PLUGS CONTROL - - SINGLE-PHASE VOLTMETRIC MAINS/GENERATOR CONTROL STARTER CONTROL REMOTE COMMANDS WITH CONTACTS (STARTUP TEST STOP) PROGRAMMING OF PARAMETERS MADE EASY BY DIP SWITCHES AVAILABLE INPUT FOR ANOMALY CLOCK FOR PROGRAMMING THE START UP OR STOPPING OF THE GENSET PROGRAMMABLE WEEKLY SELFTEST ON REQUEST GENERATOR AMMETER MAINS THREE-PHASE VOLTMETRIC CONTROL EMERGENCY BUTTON KEY FOR EMERGENCY MANUAL STARTUP GENERATOR OVERLOAD SWITCH PRE-WIRED MALE CONNECTOR ®

EMERGENCY AUTOMATIC PANELS FOR GENSET UNITS FITTING … · emergency automatic panels for genset units complete with display to show: ... fitting a diesel or gasoline engine three-

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EMERGENCY AUTOMATIC PANELS FOR GENSET UNITS FITTING … · emergency automatic panels for genset units complete with display to show: ... fitting a diesel or gasoline engine three-

Via Naviglio Alto,24/A 43100 PARMA (ITALY)Tel. 0521 772021 Fax 0521 270218

e-mail: [email protected]

GB GE/FO-130906

EMERGENCY AUTOMATIC PANELS FOR GENSET UNITS

COMPLETE WITH DISPLAY TO

SHOW:

instruments8 :

-

-

-

-

- total hour meter

- partial hour meter

-

-

useful signals for

generator set management.

mains voltmeter

generator voltmeter

generator ammeter

generator frequency meter

battery voltmeter

fuel level indicator

TYPE

LEM-435/32

LEM-430/45

LEM-430/60

45

60

3258

Three-phase

Single-phase

Amp (Ac1)

FITTING A DIESEL OR GASOLINE ENGINE

Thre

e-

phase

(On request)

SIM

ULTA

NE

OU

SR

EA

DIN

GO

F3

INS

TR

UM

EN

TS

REMOTE SWITCHING MAINS/GENSET

AUTOMATIC BATTERY CHARGING (1,5A)

AUTOMATIC SUPERVISION OF FAULTS

EJP FUNCTION

GLOW PLUGS CONTROL

- -

SINGLE-PHASE VOLTMETRIC MAINS/GENERATOR CONTROL

STARTER CONTROL

REMOTE COMMANDS WITH CONTACTS (STARTUP TEST STOP)

PROGRAMMING OF PARAMETERS MADE EASY BY DIP SWITCHES

AVAILABLE INPUT FOR ANOMALY

CLOCK FOR PROGRAMMING THE START UP OR STOPPING

OF THE GENSET

PROGRAMMABLE WEEKLY SELFTEST

ON REQUEST

GENERATOR AMMETER

MAINS THREE-PHASE VOLTMETRIC CONTROL

EMERGENCY BUTTON

KEY FOR EMERGENCY MANUAL STARTUP

GENERATOR OVERLOAD SWITCH

PRE-WIRED MALE CONNECTOR

®

Page 2: EMERGENCY AUTOMATIC PANELS FOR GENSET UNITS FITTING … · emergency automatic panels for genset units complete with display to show: ... fitting a diesel or gasoline engine three-

-SUPPLY VOLTAGE 12 VDC OR 24 VDC

-DEGREE OF PROTECTION IP40

-WALLINSTALLATION

DIMENSIONSINSTRUMENTS

• MAINS VOLTMETER

• GENERATOR VOLTMETER

• GENERATOR AMPEREMETER

• GENERATOR FREQUENCY METER

• TOTAL HOUR METER

• PARTIAL HOUR METER

• BATTERY VOLTMETER

• FUEL LEVEL INDICATOR

255

184

304284255200

8,5

316

377

400

420

SIMULTANEOUS READINGOF THREE INSTRUMENTS

(On request)

SUPPLIED ACCESSORIES

TECHNICAL DATA

KIT MOUNTING BRACKET LEM

START STOP

RESET

TEST

OFF

MANAUT

www.elcos.it

®

THE GLOW PLUGSPREHEATINGIS DISPLAYED

ALARM DUE TONO FUEL

STOPPAGE DUE TO:• BELT BREAKAGE• BATTERYCHARGING FAILURE

THE DISPLAY SHOWS:THE TOTAL OPERATINGHOURS AND THEGENSET FREQUENCY

PUSH BRIEFLYTO SHOW THEINSTRUMENTS,HOLD DOWN TOVERIFY THE LEDTEST OR THEGENERAL ALARMSSILENCINGAND TO VIEWTHE HISTORICALRECORD

AVAILABLEFAULT

STARTINGFAILUREALARM

STOPPAGE DUE TOOVERFREQUENCY

STOPPAGE DUE TOENGINEOVERHEATING

THE GENERATOR ISON: LED ONGENERATORUNDER-VOLTAGE:FLASHING LED(A FLASH THEN APAUSE)GENERATOROVER-VOLTAGE:FLASHING LED(TWO FLASHESTHEN A PAUSE)

PUSH TO STOPTHE ENGINEWHEN THECONTROL PANELIS IN MANUALFUNCTION

USER ISCONNECTED TOTHE GENERATOR

ENGINE ISRUNNING

KEY ENABLED WHEN THECONTROL PANEL IS INMANUAL OPERATION,PRESS TO DIVERT THEMAINS TO THE POWERUSERS, OR TO THEGENERATOR WHEN THEENGINE IS RUNNING

PRESS TO RESETTHIS OPERATIONENABLES ALL THEBLOCKEDFUNCTIONS

,

USER IS CONNEC-TED TO MAINS PUSH TO START

THE ENGINEWHEN THECONTROL PANELIS IN MANUALFUNCTION

MAINS VOLTAGEIS PRESENT

THE DISPLAY SHOWS:

BRIEF INSTRUCTIONS

THE DISPLAY SHOWSCLOCK FORPROGRAMMING THESTART UP ORSTOPPINGOF THE GENSET

THE FUEL LEVELINDICATORIS DISPLAYED

BATTERY CHARGERIN OPERATION

%

%

START

STOPVOLT

AMP

HZ

h

!

A1

OFF MANAUT TEST

CONTAORE TOTALE

MAINS

GENERATOR

BATTERY

CUMULATIVEALARM

STOPPAGE DUE TO:INSUFFICIENT OILPRESSURE

• VOLTMETER• MAINS/GENSETAMMETER

• GENSETFREQUENCY-METER

THE ENGINECOOLINGIS DISPLAYED TEST

OFF

MANAUT

PRESS TOSELECT THEFUNCTIONS OF:• AUT• OFF• MAN• TEST

h

PARTIALHOUR METER.SHOWS HOURS OFOPERATION SINCETHE LAST TIMETHE GENERATORSET WASSWITCHED ON.

TOTAL HOUR METER

EMERGENCYSTOP

ANOMALY HISTORICAL RECORD (Including data

from the last 100 anomalies)

STARTING

STOPPING

EJP STARTING

EJP SWITCHINGCONSENTCALL FROM EXTER-NAL VOLTMETRICRELAY

REMOTE CONTROLSDESCRIPTION

START

STOPSTART EJP

EJP

INDICATIONON THEDISPLAY