Upload
vonguyet
View
261
Download
4
Embed Size (px)
Citation preview
EMI Power Filters
CERTIFIED Signal & Power Integrity Group
&
2
Spectrum Control EMI filtered power products prevent
unwanted interference from entering your system, as
well as eliminate emissions that can contaminate the
AC power grid. Our standard and custom products
are available in a wide range of AC/DC current and
voltage ratings to address EMI filtering for high current
applications. All Spectrum power products are
designed to meet global EMC emissions regulations.
Spectrum Control is committed to providing an
integrated approach to EMC problem solving by offering
customers consulting, diagnostic testing, design and
manufacturing services. As a fully integrated manufacturer,
Spectrum Control is able to respond to short lead time
requests for new prototypes and variations to standard
products. This enables us to provide the most cost-
effective solution that satisfies both your performance
and budgetary needs.
In addition, our family of power products provide
low cost solutions to EMI challenges, helping you
lower inventories and increase production assembly
efficiency.
Spectrum Control power products are used in
a variety of industries worldwide, including telecom-
munications, computers and peripherals, medical,
aerospace, military, power supplies, appliances
and industrial controls.
CERTIFIED
EMI PowerFilters Signal & Power Integrity Group
Control ProductsSystems Company
A
3
Spectrum Control Inc...
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Single Line Filters
• Single Line Feed-thru Filters• DC Single Line Feed-thru Series• DC Single Line Pi Series
• AC Single Line Feed-thru Series• AC Single Line Pi Series
12 - 22
High Current Filtered Terminal Blocks
• High Current FilteredTerminal Blocks
23
Power Entry Modules
Bolt-in Rear TerminalsBolt-in Right Angle TerminalsHigh Frequency AttenuationSnap-in With Wire LeadsBolt-in With Wire LeadsSnap-in Mount
• Fused Filtered Power Entry Modules
• Switched & Fused Filtered Power Entry Modules
• Switched & Fused FilteredPower Entry Modules For European Market
24 - 51
PCB Power Filters
• Miniature Printed Circuit Boards
• Power Entry Modules Bolt-inRight Angle Terminals
• Power Entry Modules High Frequency Attenuation Bolt-in
• PCB Power Filters Miniature Printed Circuit Boards
52 - 59
Power Line Filters
• Appliance Filters• Single Stage• Single Stage Wire Leads• Single Stage Wire Leads for
Medical Purpose Applications
• Single Stage - Higher Current• DC - Higher Current• DC - Single Stage• Dual Stage
• Three Phase - LowCurrent/High Performance
• Three Phase • Three Phase - High Performance
60 - 97
Military/Aerospace Multisection Filters
• Military/AerospaceMultisection Filters
98 - 105
Custom/Application Specific Filters
• Custom/Application Specific Filters
106 - 109
Appendix
• Part Number Index• Design Inquiry Form• www.spectrumcontrol.com
Online tools
110 - 115
Page
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
4
EMI Power Filters Selection Guide
Applications
Features/Benefits
PerformanceCharacteristics
High CurrentFeed-thru Filters
High Current Terminal Blocks
Power EntryModules
Power Entry ModulesFused/Switched
and Fused
Cellular base stations, telephoneracks, high current switch modepower supplies, power amplifiersand servers
Cellular base stations, telecom-munication switching networks,hi-reliability radar & transmissionsystems, industrial controls,power supplies, UPS, instru-mentation and power distribution
Digital equipment, personalcomputers and peripherals,measuring instruments,home appliances, monitorand display units
Digital equipment, personalcomputers and peripherals, measuring instruments, homeappliances, monitor and display units
Current ratings (max) -To 500 Amps
Voltage ratings (max) -To 1000 VDCand to 240 VAC
Insertion loss range -AC: 1 MHz to 1 GHzDC: 150 KHz to 10 GHz
Temperature range --55°C to +125°C
Capacitance -To 4.7 µFClass Y2 and Y4 available
Current ratings (max.) -Barrier strip: 60 Amps
Voltage ratings (max.) - From 100 VDC to 250 VAC, 60 Hz
Insertion loss range -Effective insertion loss from 1 MHz to 200 MHz
Temperature range --55°C to +105°C
Capacitance -.015 µF per line or .030 µF per pair
Current ratings (max.) -Up to 15 Amps
Voltage ratings (max.) -From DC to 250 VAC, 60 Hz
Insertion loss range -Effective filtering from100 KHz to 30 MHz
Temperature range --25°C to +85°C
Leakage current range -0.35 mA to 0.50 mA max
Current ratings (max) -2, 4 and 6 Amps
Voltage ratings (max.) -125 VAC and 250 VAC
Insertion loss range -Effective filtering from100 KHz to 30 MHz
Temperature range --25°C to +85°C
Leakage current range -0.35 mA to 0.50 mA max for general purpose filters
0.005 mA to 0.10 mA max for medical filters
Easy installation -Bolt-in style, surface mount
Design flexibility -Available with single, dual,triple and quad configura-tions, different stud lengths,mounting brackets hardwareand EMI gasketing available.
Performance -Ideally suited to help meetNEBS, GR1089, andEN55022
Agency approvals -Designed to meet agencyapprovals, some selected filters UL 1950 recognized,CSA C22.2 certified andTÜV approved
Custom options -Custom interfacing, contactpins, wire leads, multiple outputs
Environmental -Can be used in both indoorand outdoor applications
Rugged construction -Provides protection to filter-ing element; especially useful for repeated in-fieldwiring changes
Design flexibility -2 x 2 to 2 x 6 position blocks
Terminal Blocks availablewith either metric or USthreaded studs
Performance -Filter elements provide high insertion loss for EMI filtering of DC power lines to help meet NEBS,GR1089, and EN55022
Agency approvals -UL recognized
Rugged construction -Designed to perform inindustrial environments
Design flexibility -Bolt-in or snap-in mounting
Available in fused orswitched and fused versions
Performance -Ideally suited for products that must conform to FCC part 15 regulations
Meets over-voltage of IEC 664 category II and complies with IEC 950
Low leakage versions available for medical applications
Agency approvals -UL recognized, CSA certified, TÜV approved(tested and found to be in accordance with VDE0565 Part 3)
Rugged construction -Designed to perform inindustrial environments
Design flexibility -Available in PCB mount,fast-on tab, solder lug or flying leads
Performance -Ideally suited for productsthat must conform to FCCpart 15 regulationsMeets over-voltage of IEC664 category II and complies with IEC 950Metal case provides maxi-mum isolation that optimizesperformance
Agency approvals -UL recognized, CSA certified,TÜV approved (tested andfound to be in accordancewith VDE 0565 Part 3)
Custom options -Value added connectors, wire leads, ring terminals
Pages 42-51Pages 24-41Pages 23Pages 12-22
www.spectrumcontrol.com/sfilter www.spectrumcontrol.com/terblk www.spectrumcontrol.com/pem www.spectrumcontrol.com/pemfsf
For data sheets on theproduct you’re looking for,enter the dedicated URL
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
5
EMI Power Filters Selection Guide
Applications
Features/Benefits
PerformanceCharacteristics
Power LineFilters
Three-PhasePower Line
Filters
Military/AerospaceMultisection Filters
Commercial CustomAssemblies
Digital equipment, personalcomputers and peripherals,measuring instruments, medical, industrial, telecommu-nications equipment, factoryautomation, UPS, vendingmachines, elevators, and switchmode power supplies
Digital equipment, industrial equipment, UPS, inverters,converters, automation equipment, computerizedindustrial washing machines,and switching power supplies
Commercial & military avionics,satellites, secured communica-tions, ruggedized computers,radar, electronic warfare, andground/air weapon systems
Telecommunications, cellularbase stations, medical equipment, telephone switching, traffic control systems, industrial work stations, servers, power supplies, UPS, industrial controls and welders
Current ratings (max) -To 260 Amps
Voltage ratings (max.) -From DC to 250 VAC, 60 Hz
Insertion loss range -Effective filtering from100 KHz to 30 MHz
Temperature range --25°C to +85°C
Leakage current range -0.35 mA to 3.0 mA max
Current ratings (max) -3 Amp to 200 Amps
Voltage ratings (max.) -250 VAC to 440 VAC
Insertion loss range -Effective filtering from100 KHz to 30 MHz
Temperature range --40°C to +85°C
Leakage current range -Standard and low leakage designs available
Current ratings (max.) -Up to 100 Amps
Voltage ratings (max.) - 400 VDC and 240 VAC standard; custom voltage ratings available
Insertion loss range -Effective filtering from 10 KHz to 10 GHz
Temperature range - -55°C to +125°C
Current ratings (max.) -Up to 250 Amps
Voltage ratings (max.) - 400 VDC and 240 VACstandard; custom voltageratings available
Insertion loss range -Effective filtering from 10 KHz to 10 GHz
Temperature range --55°C to +125°C
Leakage current range -Standard and low leakagedesigns available
Rugged construction -Designed to perform in industrial environments
Design flexibility -Available with fast-on, bolt-interminals or wire leads
Single stage and dual stage
Performance -Ideally suited for products that must conform to FCC part 15 regulations
High performance in bothmetal and plastic cases
Excellent attenuation for high voltage impulse
Agency approvals -Several styles are UL recognized, CSA certified,TÜV approved (tested andfound to be in accordancewith VDE 0565 Part 3)
Rugged construction -Designed to perform inindustrial environments
Design flexibility -Available with fast-onor bolt-in terminals
Single and dual stage
Delta and Wye configurations
Performance - Ideally suited for products that must conform to FCC part 15 regulations
Both metal and plastic casesprovide high performance
Excellent attenuation for high voltage impulse
Agency approvals -Agency approvals pending
Rugged construction -Designed to perform inindustrial environments
Design flexibility -Filters designed to meet cus-tomer’s circuit requirements
Transient protection
Circuit breakers
Voltage cut-off
Other options available
Provides quick and economi-cal solutions to meet cus-tomers’ specific requirements
Increases speed-to-marketand decreases developmenttime
Designs optimized throughEMC verification
Agency approvals -Designed to meet NEBS and safety agency approvals
Rugged construction -Metal enclosures built to withstand MIL-STD environmental conditions
Design flexibility -Standard catalog parts avail-able Parts designed to meetcustomers’ requirements
Performance - EMI designs provide excellent isolation and high frequency performance
Military approvals -Available to meet MIL-F-15733 and MIL-STD-461
Military testing IAW MIL-STD-202, MIL-STD-105
EMI design verification -Equipment verification canbe accomplished throughSpectrum Control’s EMI test lab
Pages 52-87 Pages 88-97 Pages 98-105 Pages 106-109
www.spectrumcontrol.com/pline www.spectrumcontrol.com/3pline www.spectrumcontrol.com/multi www.spectrumcontrol.com/comcus
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
6
Spectrum Control’s Expertise
Spectrum Control is unique in providing an integratedapproach to EMC problem solving by offering customerconsulting, diagnostic testing, design and manufacturingservices. As a fully integrated manufacturer, we are ableto respond to short lead times and develop cost-effectivesolutions to satisfy your performance and budgetary needs.
Test Spectrum Control’s Test Facility provides a total solution
for your compliance issues In-house anechoic chamber and shielding room NARTE certified engineering staff Tests available for:
• European emission and immunity regulations(CE Mark)
• FCC Part 15
• MIL standard testing
Design In-house EMI and power conditioning specialists Comprehensive computer modeling Designs are “in-house” compliance verified Custom assemblies:
• Incorporate EMI filtering, circuit breaker protection,transient suppression, voltage cut-off, power factor correction, harmonic suppression, remote sensingand other options to meet your specific requirements
• Plug-and-play designs
• Reduce your time to market
• Lower your inventory needs
Manufacture Flexible factories Custom designs Spectrum Control, Inc. ISO 9001 certified Schedule sharing programs available Vertically integrated supplier
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
7
Spectrum Control’s Expertise
As a complete source of EMC solutions, Spectrum Controlcombines state-of-the-art test facilities with proven exper-tise in the design and manufacture of EMI/RFI filteredpower products.
Spectrum Control offers:Engineering Support – Our experienced engineering staffwill work closely with your design and manufacturing teamto provide rapid and cost-effective solutions meeting themost stringent EMI requirements.
Reduced Lead Times and Volume Production – Ourvertical integration allows us to reduce lead times for bothprototype and production orders . . . ensuring on-timedelivery. This not only reduces your inventory, it savesyou time and money.
Custom Solutions – We offer maximum design expertiseand versatility to meet the need of any unique filteringapplication. In addition, we’ll develop power conditioningsolutions with features such as back panels with EMIfiltering and surge protection, circuit breakers, LEDsand voltage cut-off.
Full Qualification Testing – We offer a fully integratedquality assurance process, as well as testing in compliancewith MIL-F-28861, MIL-F-15733, MIL-STD-202, and otherEMI specifications. Spectrum Control’s facilities have beenaudited and qualified to MIL-I-45208 and are registered to ISO 9001.
Customer Support Programs – We will work closely with your organization to help improve the final design and performance of your products, as well as increaseyour manufacturing and operational efficiency. SpectrumControl has instituted a variety of programs designed to maximize these opportunities.
Flexible manufacturing to cut cycle times and meet deadlines
EDI to streamline the transmitting of information
Inventory Management through flexible shipping programs
Consignment/schedule sharing programs to accommodate customers’ forecasts
Broader distribution base to make our products more readily available and accommodate vendor reduction plans
New product development geared to meeting customer-specific requirements and targets
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
8
Application Guidelines
Need for EMI suppressionGlobal regulatory agencies have established limits to the amount of noise that man-made electronic devicescan radiate or conduct. These regulations have gainedgreater importance as the world’s electronic populationintensifies and the proximity of electronic devicesbecomes closer.
EMI can propagate through two basicavenues: Conducted and RadiatedConducted refers to events where the EMI energy flowsthrough power lines, data cables and other wiring thatcarries functional data or power.Radiated refers to energy that is propagated by magnetic or electric fields, which originate from otherelectronic or electrical systems.
Interference typesThere are two modes of conducted noise: differentialmode (symmetrical or normal mode) and common mode(asymmetrical mode).Differential mode interference signals are present onone side of the line, referenced to the other. The currentsflow along one phase and return along another phase.Common mode interference signals are present on bothsides of the line referenced to ground. The current flowsfrom the source to ground along the ground path andreturns along the phases.
Sources of EMIElectromagnetic interference can occur naturally or through electronic sources. Lightning discharges, precipitation, sand and dust storms, and cosmic noiseare sources of natural EMI.
EMI generated from power electrical products causethe most concern. These man-made sources, such aspower lines, rotating machinery, power supplies andelectronic transmission devices, all have their own signatures and noise pollution.
EMI filters, insertion loss and attenuationPower line EMI filters are designed to attenuate (or reduce) all radio frequency emissions or energy thatis above the applicable EMC specification. Most powerline EMI filters utilize inductor/capacitor “low pass” com-ponent configurations that pass all DC or low frequencyAC necessary energy and attenuate (suppress) higherfrequencies containing noise or unwanted energy.
To insure a customer’s “in system” unit to unit attenuation uniformity of power line filters, an insertion loss production line test is performed by Spectrum Control, Inc.
Each of the specific frequencies is measured using RF test equipment and the “reference signal level” of each frequency is stored. Some systems sweep the entire frequency range and store this “reference signal level”. Thefilter to be measured, tested, or evaluated is then “inserted”between the generator and receiver that established thestored “reference signal level” on the RF test analyzer.
The measured difference without a filter (“the referencesignal level”) and with the filter “inserted” into the RF testequipment/analyzer is defined as insertion loss. The unit of measure for insertion loss is the decibel (dB). As notedon most curves in this bulletin, as frequency increases, the higher the insertion loss or dB value. The plot of frequency versus dB value establishes the typical insertion loss curve.
Installation CriteriaProper installation of a filter network is critical to achievingsuccessful filtering of electromagnetic interference.Spectrum Control recommends that power line filters beinstalled where the power line enters the equipment. Thefilter acts as a barrier between polluted energy and cleanenergy going into your equipment. It is important that thefilter is connected to an effective ground plane and whereproximity does not couple radiated noise to the clean lines.
POWERINPUT
CLEANLINE
POWERINPUT
DENOTESCOUPLINGFROM NOISYCIRCUITSBACK TOLINE
LINE FILTER
CABINET
CORRECT
LINEFILTER
DENOTESCOUPLINGFROM NOISYCIRCUITSBACK TOLINE
CABINET
INCORRECT
Power Filter Installation
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
9
Measurement Guidelines
Spectrum Control has the capability to perform a wide range of tests for EMI filters. Unique custom testing systems, designed by Spectrum Control assure the accuracy required in today’s demanding environments.Testing is performed by employing a 50 ohm source andload impedance per MIL-STD-220. The individual filter performance is stated in terms of insertion loss. Overallattenuation reflects the filter’s interaction within the system.Individual filter performance may differ from system to system and each application should be verified throughsystem testing. Examples of various testing abilities andconfigurations are outlined below.
Differential (Normal or Symmetrical)Mode Insertion LossDifferential mode noise is caused by non-sinusoidal conduction of rectifiers and other switching devices creating harmonic distortion.
This noise is predominant from the power frequency to approximately 10 MHz. Since it follows conventional current flow, it is considered to be of the same magnitudebut opposite phase of the other line. Spectrum Controlmeasures differential mode insertion loss in a 50 ohm system with Balun transformers as shown.
Common (Asymmetrical) Mode Insertion LossSince common mode insertion loss is of the same phase as the opposite line, they may not be of the same magnitude, depending on the end system circuitry.Spectrum Control tests common mode insertion loss oneach line in a 50 ohm system as shown.
Leakage CurrentLeakage is a measurement of reactive current (capaci-tance) to ground per line. Spectrum Control uses the following test setup for leakage current measurement.
AC Voltage DropAC voltage drop is defined as E in - E out = AC voltage drop.
Spectrum Control uses the following circuit for AC voltagedrop testing:
DC Voltage DropDC voltage drop is performed on each line individually.This test provides the total DC voltage drop for that line of the filter. The following circuit is used in testing:
DEVICEUNDERTEST
TIES TO CHASSISOF DEVICE
ACSOURCE
1
2
1 NEUTRAL TEST2 HIGH TEST
INSULTATED TABLE
v1.5 KΩ
0.15 µFD
IN ACCORDANCE WITH U.L. 1283 METHOD
E1 DUT(FILTER) E2
A
DUT(FILTER)
A
EVD
RS
RECEIVER
LINE50Ω
50Ω
LINE
NEUT NEUT
FILTER
FILTER Ø A
FILTER Ø B
FILTER Ø C
RECEIVER
BALUNBALUN
SIGNALGENERATOR
50Ω
50Ω
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
10
EMC Testing Solutions
Spectrum Control is a solutions-oriented EMC test corporation committed to effectively satisfying worldwideEMC standards for commercial and military equipment.Our EMC testing services offer you a flexible resource to assist in product development by identifying and correcting EMI susceptibility and/or emission problems.
Our commitment to our customers goes much furtherthan any other EMI filtered power products manufacturer.Spectrum Control has a fully equipped EMC TestLaboratory and experienced engineering staff ready to solve your most demanding EMC challenges.
We can test your equipment, system or subsystem tovarious domestic and international regulatory standards,determine state of compliance, and develop the mostcompact and cost-effective solution. These services (EMCtesting and compliance recommendations) are availablefor a modest daily fee. It is not uncommon for clients leaveSpectrum Control’s EMC Test Laboratory with a prototypein hand.
State-of-the-art Testing Two test environments available: anechoic
chamber and shielded room Baseline of device under test in ambient-free
anechoic chamber Computer controlled pre-selected EMI receivers
with quasi-peak detection accumulate data for displaying information in graphical or tabular formats
Fiber optic coupled video cameras for dynamic test observation
Computer generated test data reduces time andimproves accuracy
Testing CapabilitiesUL Underwriter’s Laboratories, UL 1283
MILITARY
MIL-STD-461 A/B/C/D and MIL-STD-1399
AUTOMOTIVE
SAE-J1113, SAE-J551
COMMERCIAL
FCC-Part 15
RTCA-DO-160 A/B/C Boeing-16050-2
Bellcore-TR-NWT-001089
INTERNATIONAL
EN 55011 (CISPR 11)
EN 55014 (CISPR 14)
EN 55022 (CISPR 22)
IEC-1000-4-02 ESD
IEC-1000-4-03 RFI
IEC-1000-4-04 EFT
IEC-1000-4-05 Surge
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
11
EMC Testing Solutions
One of the most significant advantages of SpectrumControl’s testing services lies in our experience and expertise in evaluating, designing and producing productsfor the suppression of EMI. Our approach to EMC testingenables us to identify, as well as solve any problems orpotential problems found in your system. Spectrum’sdesign and production engineers will work with your engineering team to develop a filter solution that eliminates your EMI problems.
Once we have identified an EMI failure, we will developa prototype design, integrate the EMC modification intoyour device or system, and verify compliance to the appropriate test specifications. Spectrum Control maintainssemi-automated and automated manufacturing facilities to economically produce the modification installed duringtesting. Through these capabilities your equipment willleave Spectrum Control with a prototype, as well as a fully compliant system.
Test Spectrum Control Test Facility
will define compliance issues In-house anechoic chamber
and shielded room NARTE certified engineering staff Test available for:
• European emission and immunity regulations
• FCC Part 15• MIL 461 Series
Design In-house EMI specialists Computer modeling CAD systems internet accessible Designs are “in-house”
compliance verified Value-added designs:
• Incorporate circuits and additional components
• Ease of production assembly
• Lower inventory needs
Manufacture Flexible operations Custom designs built in U.S.A. ISO 9001 certified facilities Workmanship MIL-STD-2000
certified Schedule sharing programs
available Vertically integrated
EMI filter supplier
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
12
High Current
DC Single Line Feed-thru Series
Features Voltage Rating 130VDC C Configuration with Class Y4 capacitors Current rating up to 300 Amps Operating Temperature Range: -40C to +85C Excellent filtering in compact package Bolt-in style with D-shaped bushing for easy installation Low cost EMI solution Design flexibility UL and Semko approved
Applications Telecommunications (cellular base stations,
telephone switching racks, etc.) Power supplies Medical Equipment C.O.T.S. (Commercial-Off-The-Shelf) Military Industrial equipment controls Data Transmission Equipment
Sing
le L
ine
Filt
ers
Part Rated Min. Minimum Insertion Loss (db)*Number Current Cap. .01MHz .10MHz 1MHz 10MHz 100MHz 1000MHz
52-226-011-10 10A52-226-011-16 16A
10nF – 4 21 41 6052-226-011-32 32A52-226-011-63 63A52-226-011-100 100A 47nF 2 15 34 53 7452-226-011-200 200A –52-226-011-250 250A 100nF 5 21 40 60 8552-226-011-300 300A52-226-021-16 16A52-226-021-32 32A 47nF 2 15 34 53 7452-226-031-63 63A52-226-021-100 100A 100nF 5 21 40 60 8552-226-021-200 200A52-226-021-250 250A 470nF 2 16 33 52 75 9052-226-021-300 300A52-226-031-16 16A52-226-031-32 32A 100nF – 5 21 40 60 8552-226-031-63 63A52-226-031-100 100A 470nF 2 16 33 52 7552-226-031-200 200A52-226-031-250 250A 1000nF 6 20 40 60 8552-226-031-300 300A52-226-041-16 16A 9052-226-041-32 32A 470nF 2 16 33 52 7552-226-041-63 63A52-226-041-100 100A 1000nF 6 20 40 60 8552-226-041-200 200A 4700nF 15 35 54 74 90
* Optimum performance with proper installation
Specifications
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
13
Part Number A B C D E F
52-226-011-10 2.24 (57) 0.39 (10) 0.51 (13) 0.56 (14.29) 0.63 (16)52-226-011-16
2.48 (63) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18)0.71 (18)
52-226-011-3252-226-011-63 3.78 (96) 0.55 (14) 0.87 (22) 1 (25.40) 1.02 (26) 1.18 (30)52-226-011-100 4.45 (113) 0.63 (16)
1.06 (27) 1.25 (31.75)1.26 (32)
1.30 (33)52-226-011-200 5.12 (130) 1.57 (40)52-226-011-250
5.83 (148)0.75 (19)
1.57 (40) 2 (50.80) 1.81 (46) 1.65 (42)52-226-011-30052-226-021-16
2.95 (75) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18)1.18 (30)52-226-021-32
52-226-031-63 3.78 (96) 0.55 (14) 0.87 (22) 1 (25.40) 1.02 (26)52-226-021-100 4.45 (113) 0.63 (16)
1.06 (27) 1.25 (31.75)1.26 (32)
1.30 (33)52-226-021-200 5.12 (130) 1.57 (40)52-226-021-250
6.30 (160)0.75 (19)
1.57 (40) 2 (50.80) 1.81 (46) 2.13 (54)52-226-021-30052-226-031-16
2.95 (75) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18)1.18 (30)52-226-031-32
52-226-031-63 3.78 (96) 0.55 (14) 0.87 (22) 1 (25.40) 1.02 (26)52-226-031-100 4.45 (113) 0.63 (16)
1.06 (27)1.25 (31.75) 1.26 (32) 1.30 (33)
52-226-031-200 5.79 (147) 1.5 (38.10) 1.57 (40) 1.97 (50)52-226-031-250
7.01 (178)0.75 (19)
1.57 (40) 2 (50.80) 1.81 (46) 2.83 (72)52-226-031-30052-226-041-16
3.23 (82)0.63 (16) 1.25 (31.75)
0.71 (18)1.30 (33)52-226-041-32
52-226-041-63 3.98 (101)1.06 (27)
1.02 (26)52-226-041-100 5.24 (133)
0.75 (19)1.5 (38.10) 1.26 (32) 1.97 (50)
52-226-041-200 6.50 (165) 1.57 (40) 2 (50.80) 1.57 (40) 2.68 (68)
High Current
DC Single Line Feed-thru Series
F B
E C
A
D
.025 (.64) SHOULDER
WORKORDER NO.
DATE CODESINGLE "D"MOUNTING FLAT
Dimensions
Sing
le L
ine
Filt
ers
Dimensions in inches (mm)
Part Rated Min. Minimum Insertion Loss (db) *Number Current Cap. (2X) .01MHz .10MHz 1MHz 10MHz 100MHz 1000MHzStandard Performance52-226-020-10 10A
0.5 823
7052-226-020-16 16A 10nF
–35
52-226-020-32 32A 2 10 23 5090
52-226-020-63 63A 100nF 8 27 6752-226-020-100 100A
470nF4 21
3070 90
52-226-020-200 200A 7 23 60High Performance52-226-029-10 10A52-226-029-16 16A 100nF – 8 25 7552-226-029-32 32A52-226-029-63 63A 470nF 4 21 35 70
90 90
52-226-029-100 100A 1000nF 8 26 57 7352-226-029-200 200A 4700nF 20 40 85 90
* Optimum performance with proper installation
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
14
High Current
DC Single Line Pi Series
Features Voltage Rating 130VDC Pi Configuration with Class Y4 capacitors Current rating up to 200 Amps Excellent filtering in compact package Bolt-in style with D-shaped bushing for easy installation Low cost EMI solution UL and Semko approved
Applications Telecommunications (cellular base stations,
telephone switching racks, etc.) Power supplies Medical Equipment C.O.T.S. (Commercial-Off-The-Shelf) Military Industrial equipment controls Data Transmission Equipment
Sing
le L
ine
Filt
ers
Specifications
Circuit Diagram
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
15
High Current
DC Single Line Pi Series
Part Number A B C D E F
Standard Performance52-226-020-10 3.54 (90) 0.63 (16) 1.93 (49)52-226-020-16
3.86 (98)0.47 (12) 0.67 (17) 0.75 (19.05)
0.71 (18) 2.09 (53)52-226-020-3252-226-020-63 6.30 (160) 0.55 (14) 0.87 (22) 1 (25.40) 1.02 (26) 3.70 (94)52-226-020-100 7.24 (184) 0.63 (16)
1.06 (27)1.25 (31.75) 1.26 (32) 4.09 (104)
52-226-020-200 8.23 (209) 0.75 (19) 1.50 (38.10) 1.57 (40) 4.41 (112)High Performance52-226-029-10 5.12 (130) 0.63 (16) 3.50 (89)52-226-029-16
5.47 (139)0.47 (12) 0.67 (17) 0.75 (19.05)
0.71 (18) 3.70 (94)52-226-029-3252-226-029-63 6.81 (173) 0.63 (16)
1.06 (27)1.25 (31.75) 1.02 (26) 4.13 (105)
52-226-029-100 8.98 (228)0.75 (19)
1.50 (38.10) 1.26 (32) 5.71 (145)52-226-029-200 11 (279) 1.57 (40) 2 (50.80) 1.57 (40) 7.17 (182)
Dimensions
F
B
E C
A
D
.025 (.64) SHOULDER
WORKORDER NO.
DATE CODE SINGLE "D"MOUNTING FLAT
Sing
le L
ine
Filt
ers
Dimensions in inches (mm)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
16
Part Rated Min. Minimum Insertion Loss (db) *Number Current Cap. .01MHz .10MHz 1MHz 10MHz 100MHz 1000MHz
52-226-016-10 10A 2.2nF - 9 30 4552-226-016-16 16A
4.7nF – 2 15 34 5452-226-016-32 32A52-226-016-63 63A 10nF 4 21 41 6052-226-016-100 100A 47nF 2 15 34 53 7452-226-016-200 200A52-226-016-250 250A 100nF 5 21 40 60 8552-226-016-300 300A52-226-026-10 10A 4.7nF 2 15 34 5452-226-026-16 16A
10nF–
4 21 41 6052-226-026-32 32A –52-226-026-63 63A 47nF 2 15 34 53 7452-226-026-100 100A 100nF 5 21 40 60 8552-226-026-200 200A52-226-026-250 250A 220nF 10 27 47 67 9052-226-026-300 300A52-226-036-16 16A 47nF 2 15 34
5374
52-226-036-32 32A 33nF 3 16 35 9052-226-036-63 63A 100nF 5 21 40 60 8552-226-036-100 100A 220nF 10 27 47 6752-226-036-200 200A52-226-036-250 250A 470nF 2 16 33 52 75
90
52-226-036-300 300A52-226-046-16 16A 100nF 5 21 40 60 8552-226-046-32 32A 47nF – 2 15 34 53 7452-226-046-63 63A 220nF 10 27 47 6752-226-046-100 100A 470nF 2 16 33 52 7552-226-046-200 200A52-226-046-250 250A 1000nF 6 20 40 60 85
90
52-226-046-300 300A
* Optimum performance with proper installation
High Current
AC Single Line Feed-thru Series
Features Voltage Rating 250VAC C Configuration with Class Y2 capacitors Current rating up to 300 Amps Excellent filtering in compact package Bolt-in style with D-shaped bushing for easy installation Low cost EMI solution Design flexibility UL and Semko approvals pending
Applications Telecommunications (cellular base stations,
telephone switching racks, etc.) Power supplies Medical Equipment C.O.T.S. (Commercial-Off-The-Shelf) Military Industrial equipment controls Data Transmission Equipment
Sing
le L
ine
Filt
ers
Specifications
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
17
High Current
AC Single Line Feed-thru Series
Part Number A B C D E F
52-226-016-10 2.24 (57) 0.39 (10) 0.51 (13) 0.56 (14.29) 0.63 (16)52-226-016-16
2.48 (63) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18)0.71 (18)
52-226-016-3252-226-016-63 3.78 (96) 0.55 (14) 0.87 (22) 1 (25.40) 1.02 (26) 1.18 (30)52-226-016-100 4.45 (113) 0.63 (16)
1.06 (27)1.25 (31.75) 1.26 (32)
1.30 (33)52-226-016-200 5.12 (130) 1.5 (38.10) 1.57 (40)52-226-016-250
5.83 (148)0.75 (19)
1.57 (40) 2 (50.80) 1.81 (46) 1.65 (42)52-226-016-30052-226-026-10 2.24 (57) 0.39 (10) 0.51 (13) 0.56 (14.29) 0.63 (16)
0.71 (18)52-226-026-162.48 (63) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18)
52-226-026-3252-226-026-63 3.78 (96) 0.55 (14) 0.87 (22) 1 (25.40) 1.02 (26) 1.18 (30)52-226-026-100 4.45 (113) 0.63 (16)
1.06 (27)1.25 (31.75) 1.26 (32)
1.30 (33)52-226-026-200 5.12 (130) 1.5 (38.10) 1.57 (40)52-226-026-250
5.83 (148)0.75 (19)
1.57 (40) 2 (50.80) 1.81 (46) 1.65 (42)52-226-026-30052-226-036-16
2.95 (75) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18)1.18 (30)52-226-036-32
52-226-036-63 3.78 (96) 0.55 (14) 0.87 (22) 1 (25.40) 1.02 (26)52-226-036-100 4.57 (116) 1.06 (27) 1.26 (32) 1.30 (33)52-226-036-200 5.79 (147)
1.5 (38.10)1.57 (40) 1.97 (50)
52-226-036-2506.30 (160)
0.75 (19)1.57 (40)
2 (50.80) 1.81 (46) 2.13 (54)52-226-036-30052-226-046-16 3.03 (77) 0.55 (14) 0.87 (22)
1 (25.40) 0.71 (18) 1.18 (30)52-226-046-32 2.95 (75) 0.47 (12) 0.67 (17)52-226-046-63 4.45 (113) 0.63 (16)
1.06 (27)1.25 (31.75) 1.02 (26) 1.30 (33)
52-226-046-100 5.24 (133) 1.5 (38.10) 1.26 (32)1.97 (50)
52-226-046-200 5.79 (147)0.75 (19)
1.57 (40)52-226-046-250
6.30 (160)1.57 (40) 2 (50.80)
1.81 (46)52-226-046-300
2.13 (54)
Dimensions
F B
E C
A
D
.025 (.64) SHOULDER
WORKORDER NO.
DATE CODE
SINGLE "D"MOUNTING FLAT
Sing
le L
ine
Filt
ers
Dimensions in inches (mm)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
18
Part Rated Min. Minimum Insertion Loss (db) *Number Current Cap. (2X) .01MHz .10MHz 1MHz 10MHz 100MHz 1000MHz
Standard Performance52-226-037-10 10A 4.7nF – 4 19 7752-226-037-16 16A
10nF – 1 8 22 5052-226-037-32 32A52-226-037-63 63A 47nF 4 21 52 80 9052-226-037-100 100A 8 25 7352-226-037-200 200A
100nF 1 9052-226-037-250 250A 9 26 7552-226-037-300 300AHigh Performance52-226-019-10 10A 10nF 1 9 3052-226-019-16 16A
22nF–
3 15 4780
52-226-019-32 32A52-226-019-63 63A 150nF 1 12 27 75 9052-226-019-100 100A 3952-226-019-200 200A
470nF 4 21 85 9052-226-019-250 250A 5752-226-019-300 300A
* Optimum performance with proper installation
High Current
AC Single Line Pi Series
Features Voltage Rating 250VAC Pi Configuration with Class Y2 capacitors Current rating up to 300 Amps Excellent filtering in compact package Bolt-in style with D-shaped bushing for easy installation Low cost EMI solution Design flexibility UL and Semko approvals pending
Applications Telecommunications (cellular base stations,
telephone switching racks, etc.) Power supplies Medical Equipment C.O.T.S. (Commercial-Off-The-Shelf) Military Industrial equipment controls Data Transmission Equipment
Sing
le L
ine
Filt
ers
Circuit Diagram
Specifications
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
19
High Current
AC Single Line Pi Series
F
B
E C
A
D
.025 (.64) SHOULDER
WORKORDER NO.
DATE CODE SINGLE "D"MOUNTING FLAT
Part Number A B C D E F
Standard Performance52-226-037-10 3.86 (98) 0.63 (16) 2.24 (57)52-226-037-16
4.17 (106)0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18) 2.40 (61)
52-226-037-3252-226-037-63 6.30 (160) 0.55 (14) 0.87 (22) 1 (25.40) 1.02 (26) 3.7 (94)52-226-037-100 7.24 (184) 0.63 (16)
1.06 (27)1.25 (31.75) 1.26 (32) 4.09 (104)
52-226-037-200 8.23 (209) 1.57 (40) 4.41 (112)52-226-037-250
7.87 (200)0.75 (19)
1.57 (40)1.5 (38.10)
1.81 (46) 3.66 (93)52-226-037-300High Performance52-226-019-10 4.21 (107) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.63 (16) 2.6 (66)52-226-019-16
4.57 (116) 0.55 (14) 0.87 (22) 1 (25.40) 0.71 (18) 2.72 (69)52-226-019-3252-226-019-63 6.81 (173) 0.63 (16)
1.06 (27)1.25 (31.75) 1.02 (26) 4.13 (105)
52-226-019-100 8.98 (228) 1.5 (38.10) 1.26 (32) 5.71 (145)52-226-019-200 9.57 (243)
0.75 (19)5.75 (146)
52-226-019-25010.5 (267)
1.57 (40) 2 (50.80) 1.57 (40)6.30 (160)
52-226-019-300
Dimensions
Sing
le L
ine
Filt
ers
Dimensions in inches (mm)
High Current
Single Line Feed-thru FiltersHigh current single line feed-thru filters from SpectrumControl are ideal to meet broad frequency applications.This series filters EMI/RFI with 150-500 Amp current withAC and DC voltages. These filters are ideal for cellularbase stations, telephone switching stations and high voltage power supply applications.
Features Ideal for high current applications Excellent filtering in a compact, durable package Bolt-in style for easy installation Current ratings to 500 Amps Voltage ratings up to 1000VDC and 240VAC Available with single, dual, and triple feed-thrus Various capacitance ratings (up to 1.68 µF) Rugged construction for indoor and outdoor
applications Various mounting brackets available Low cost EMI solution Design flexibility Custom mechanical configurations available
Applications Telecommunications (cellular base stations,
telephone switching racks, etc.) Power supplies Servers
Typical Insertion Loss (dB)
0.1 1 10 100Frequency (MHz)
0.01µF
0.02µF
0.04µF
0.03µF
70
60
50
40
30
20
10
0
80
0.01 1000
1.68µF
90
Electrical SpecificationsCurrent Ratings/Bolt Size: 150 Amps . . . . . . 10 mm
200 Amps . . . . . . 12 mm250 Amps . . . . . . 12 mm300 Amps . . . . . . 14 mm400 Amps . . . . . . 16 mm500 Amps . . . . . . 18 mm
Temperature Range: -25°C to 85°C
Sing
le L
ine
Filt
ers
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
20
Part Voltage Rating @ Current Capacitance Number
Figure-40C to +85C Rating Value
52-226-001 A 50VDC Max. 300 Amps 0.02 µF min. @ 50VDC
52-226-002 B 50VDC Max. 300 Amps 0.02 µF min. @ 50VDC
52-226-006 C 50VDC Max. 150 Amps 0.02 µF min. @ 50VDC
52-226-008 D 75VDC Max. 200 Amps 0.02 µF min. @ 50VDC
52-226-009 E 50VDC Max. 150 Amps 0.02 µF min. @ 50VDC
52-267-008 F 200VDC Max. 200 Amps 0.02 µF min. @ 40VDC
52-226-004 F 200VDC Max./240 VAC 200 Amps 1.68 µF min. @ 50VDC
52-226-015 G 200VDC Max./240 VAC 200 Amps 1.68 uF min. @ 50VDC
52-267-002 H 200VDC Max./240 VAC 200 Amps 1.68 µF min. @ 40VDC
52-267-003 J 200VDC Max./240 VAC 200 Amps 1.68 µF min. @ 40VDC
52-267-009 F 200VDC Max./240 VAC 60 Amps 1.68 µF min. @ 50VDC
52-267-010 K 200VDC Max./240 VAC 250 Amps 1.68 µF min. @ 40VDC
52-267-011 K 200VDC Max./240 VAC 100 Amps 1.68 µF min. @ 40VDC
52-267-012 K 250VDC Max. 100 Amps 1.00 µF+20% @ 40VDC
Ø .874 (22.20) (2x)
.177 (4.5) (2x)
1.299(33.0)
1.984(49.5)
1.496(38.0)
.807 (20.5)
5.393 (137.0)5.039 (128.0) .177 (4.5) (2x)
.826 (21.0)
1.652 (42.0)
Ø .204 ± .005(5.2 ± .13) THRU (4x)
Ø .118 ± .005(3.0 ± .13)
M10 x 1.5-6g STUDTIN PLATED BRASS1.295 ± .02 (2x)(32.9 ± 0.6)
.063 (1.6)
Ø 1.25(31.75)
2.598 MAX.(66.0)
4.015 ± .02(102.0 ± .6)
.826 (21.0) MIN.
Ø1.50(38.8)
.063(1.6)
4.67 (118.6)
4.20 (106.6) .236 (6.0) (2x).314 (8.0) (2x)
1.811 (46.0)
1.498(38.0)
1.587(40.3)
1.221 (31.0)
2.441 (62.0)
2.598(66.0)MAX.
1.295 ± .02 (2x)(32.9 ± 0.6)
4.015 ± .02(102.0 ± 0.6)
.826 (21.0)MIN. THRD.
LENGTH
2.047 ± .02(52.0 ± 0.6)
.125 (3.18) TYP.FOR LABEL LOCATION
DATE CODE
SCI 24-0058-4700 (3x)
SCI 24-0058-4800
M14 x 2.0 - 6g STUD (2x)
SCI 22-0833-0100BRACKET ASSEMBLY
SCI 24-0058-4800
Ø .204 ± .005 THRU (4x) (5.2 ± .13)
High Current
Single Line Feed-thru Filters
SQ 52 - 226 - 004200VDC 200A XXXX
1.102 ±0.02(28.0 ± .5)
.921 (23.4)
.047(1.2)3.976 ±0.02
(101.0 ±0.5)
.961 ±0.02(24.4 ±0.5) 1.890
(48.0) 1.969 ±0.02(50.0 ±0.5)
M10x1.5 – 6g STUDS
1.909 ±0.02(48.5 ±0.5)
3.799(96.5)
3.406(86.5) 1.801
(45.75)
0.197(5.00)
0.197(5.00)
1.772(45.0)1.378
(35.0)0.689(17.5)
1.053 ±0.01(26.75 ±0.3)
(6x) ø 0.185 ±0.004(4.70 ±0.1)
(2x) ø1.378 ± 0.004(MAX) (35.0 ±0.1)
0.197(5.00)
Mechanical DimensionsFigure A
4.669 (118.6)
4.196 (106.6).314 (8.0) (2x)
1.496(38.0)
1.586(40.3) Ø .204 (5.2)
THRU (4x)
2.441(62.0)
1.220(31.0)
.236 (6.0) (2x)
1.295 ± .02(32.9 ± 0.6) (2x)
2.598 MAX.(66.0)
4.015 ± .02(102.0 ± 0.6)
.826 (21.0)MIN. THRD. LENGTH
.125 (3.18) TYP.FOR LABELLOCATION
DATE CODE
45˚ CHAMFERBOTH ENDS
SCI 24-0058-4800
M14 x 2.0-6g STUD (2x)
.276 ± .016(7 ± .4)
.063(1.6)
Ø 1.25 (31.75)
1.811(46.0)
Ø .874 (22.20) (2x)
.177 (4.5) (2x)
1.299(33.0)
1.984(49.5)
1.496(38.0)
.807 (20.5)
5.393 (137.0)5.039 (128.0) .177 (4.5) (2x)
.826 (21.0)
1.652 (42.0)
Ø .204 ± .005(5.2 ± .13) THRU
Ø .118 ± .005(3.0 ± .13)
M10 x 1.5-6g STUDTIN PLATED BRASS1.295 ± .02 (2x)(32.9 ± 0.6)
M10 x 1.5-6g STUD-BRASS (UNPLATED)
1.413 ± .002(35.9 ± 0.6)
.248 (6.3) (2x)
.429 (10.9) .063 (1.6)
Ø 1.25(31.75)
2.598 MAX.(66.0)
4.015 ± .02(102.0 ± 0.6)
.826 (21.0) MIN. DATE CODE
2.0
Ø .874 (22.20) (2x)
.177 (4.5) (2x)
1.299(33.0)
1.984(49.5)
1.496(38.0)
.807 (20.5)
5.393 (137.0)5.039 (128.0) .177 (4.5) (2x)
.826 (21.0)
1.652 (42.0)
Ø .204 ± .005(5.2 ± .13) THRU (4x)
Ø .118 ± .005(3.0 ± .13)
M10 x 1.5-6g STUDTIN PLATED BRASS
1.295 ± .02 (2x)(32.9 ± 0.6)
M10 x 1.5-6g STUD-BRASS (UNPLATED)
1.421 ± .012[36.1 ± 0.3]
.248 [6.3] (2x)
.429 [10.9] .063 (1.6)
Ø 1.25(31.75)
1.89 0± .02 MAX.(48.0 ± 0.6)
2.717 ± .02(89.0 ± .6)
.826 (21.0) MIN.
DATE CODE
M10 x 1.5-6g STUDTIN PLATED BRASS
7.0MIN.
Sing
le L
ine
Filt
ers
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
21
Dimensions in inches (mm)
Figure B
Figure C Figure D
Figure FFigure E
High Current
Single Line Feed-thru Filters
3.956(100.5)
3.405(86.5)
Ø 1.378(35.0)
.964(25.4)
1.702(43.25) 1.506
(38.25)
1.378(35.0) 1.929
(49.0)
PEM CLS-M4-1(6 PLACES)
1.023(26.0)
1.909 ± 1.968(48.5 ± 50)
1.259(32.0)
.248(6.3) 1.889
(48.0)
.078(2.0)MAX.
RED
.984(25.0)
BLACK
8.858 + .787/-0(225.0 + 20.0/-0)
10.433 + .78/-0(265.0 + 20.0/-0)
7.480 + .787/-0(190.0 + 20.0/-0)
2.955 (75.0)
5.516 (140.0)
2.726 (69.2)
1.363 (34.6)
M10 x 1.5-6g STUD
5.520 (140.10)
2.092 (53.10)
1.382 (35.08)
1.777 (45.10)3.428 (87.00)
2.719 (69.00)
1.52 (.060)
2.955 (75.0)
5.516 (140.0)
2.726 (69.20)
1.363 (34.60)
5.520 (140.10)
4.570 (116.00)
2.403 (51.00)
2.285 (58.00)
Ø .283 (7.2) (2x)
PEM BSOS-M4-6 (6x)
M10 x 1.5-6g STUD
.080 (1.52)
2.092 (53.10)
1.382 (35.08)
1.777 (45.10)3.428 (87.00)
2.719 (69.00)
4.807 (122.00)
Sing
le L
ine
Filt
ers
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
22
Dimensions in inches (mm)
Figure G
Figure J
Figure H
3.799 (96.5)
3.406 (86.50)1.801
(15.75)
0.197 (5.0)
0.197 (5.0)
1.772 (45.0)
1.378 (35.00)
0.689 (17.5)
ø 0.185±0.004(6x) (4.70±0.1)
.197(5.0)
1.053±0.01(26.75±0.3)1.909±0.02
(48.5±0.5)
(MAX) ø 1.378±0.004(2x) (35.0±0.1)
0.610±0.02(15.5±0.5)
.047 (1.2)
0.118±0.02(3±0.5)
3.19±0.16(81.0±4)
.039 (1.00)
1.890 (48.0)
1.969±0.02(50.0±0.5)
Figure K
Filt
ered
Ter
min
al B
lock
s
SpecificationsELECTRICALVoltage rating: 100 VDC per terminalCapacitance: .015µF* +80% / -20% per cap
.030µF +80% / -20% per pairDielectricwithstanding voltage: 1000VDC for 1 minuteCurrent rating: 60 Amps max per terminal
MECHANICALCenter spacing: US .200: (5.08 mm)Wire size: AWG #12-26Screw material: steel, zinc chromate plateRecommended PCBhole diameter: .05" (1.30 mm) contact holeMolded material: UL rated 94VO polyamideTightening torque: 2.5 in.-lbs. max. (28 Ncm)Terminal: Brass, tin-plated
* For filter elements with additional capacitance values,consult factory.
Features Ideal for high current applications Design flexibility Available in 2 x 2 thru 2 x 6 positions UL approved
Applications Telecommunications switching networks Cellular base stations Power supplies UPS Instrumentation High reliability radar and transmission systems Industrial controls Power distribution Typical Insertion Loss — dB:
In 50 Ohm Circuit
1 MHz....... 8 70 MHz......... 365 MHz....... 24 100 MHz......... 33
10 MHz....... 32 160 MHz......... 2550 MHz....... 38 200 MHz......... 25
Part Number of A B CNumber Terminals in. (mm) in. (mm) in. (mm)
52-1013-102 2x2 2.60 66.04 2.00 50.80 1.66 42.16
52-1013-103 2x3 3.35 85.09 2.75 69.85 2.41 61.21
52-1013-104 2x4 4.10 104.14 3.50 88.90 3.16 80.25
52-1013-105 2x5 4.85 123.19 4.25 107.95 3.91 99.31
52-1013-106 2x6 5.60 142.24 5.00 127.00 4.66 118.36
High CurrentFiltered Terminal Blocks
23SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-835-1650 • Fax: 814-835-1651 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Dimensions in inches (mm)
4.600 (116.8)
1.625(41.3)
R.125 (3.2) (4X)
.65 MIN (16.5) (6X)
1.10 (27.9)
1.15 (29.1)
8-32 THREADEDINSERTS (4X)
.80 MIN (20.3)
.75 (19.0) (5X)
.75 (19.0)2.025(51.4)
2.625(66.7)
5.0 (127)5.6 (142.2)
4.6 (116.8)5.0 (127)
PANEL CUTOUT
.172 (4.3) (4X)
1.685(42.8)
2.025(51.4)
Pow
er E
ntry
Mod
ules
Power Entry ModulesBolt-in Rear Terminals
Specifications
Features Ideally suited for products that must
conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II
and complies with IEC 950 Uses IEC connector that meets most safety standards Solder lug and Fast-on tab terminals available Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 25) UL approved low leakage version also available
Applications Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units
60-XXX-010-3-20.35mA 2200pF ± 20%
.022uF ± 20%
60-XXX-010-3-4250VAC 1A
.047uF ± 20%6.0mH 30°C
60-XXX-010-5-20.50mA 3300pF ± 20%
.022uF ± 20%
60-XXX-010-5-4 .047uF ± 20%
60-XXX-020-3-20.35mA 2200pF ± 20%
.022uF ± 20%
60-XXX-020-3-4250VAC 2A
.047uF ± 20%2.4mH 30°C
60-XXX-020-5-20.50mA 3300pF ± 20%
.022uF ± 20%
60-XXX-020-5-4 .047uF ± 20%
60-XXX-030-3-20.35mA 2200pF ± 20%
.022uF ± 20%
60-XXX-030-3-4250VAC 3A
.047uF ± 20%1.2mH 30°C
60-XXX-030-5-20.50mA 3300pF ± 20%
.022uF ± 20%
60-XXX-030-5-4 .047uF ± 20%
60-XXX-060-3-20.35mA 2200pF ± 20%
.022uF ± 20%
60-XXX-060-3-4250VAC 6A
.047uF ± 20%0.53mH 45°C
60-XXX-060-5-20.50mA 3300pF ± 20%
.022uF ± 20%
60-XXX-060-5-4 .047uF ± 20%
60-XXX-100-3-2250VAC 10A
0.35mA 2200pF ± 20%.022uF ± 20% 0.26mH 45°C
60-XXX-100-5-2 0.50mA 3300pF ± 20%
60-BPR-150-3-11 250VAC 15A 0.35mA 2200pF ± 20% .01uF ± 20% 0.15mH 45°C
Model*Rated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY CX (L1) Rise (Max.)
Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 45gInput: Compatible with IEC-320
Tested and found to beIAW VDE 0565 Part 3.
* Substitute BPR or BPS for XXXBPS - Solder lug terminalsBPR - Fast-on tab terminals
60-BPR & BPS Series
Circuit Diagram
1
E
2
3
E
4
CX
CY
CY
L1
24 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Entry ModulesBolt-in Rear Terminals
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Common Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Normal Mode
2.263 (57.5)
1.476 (37.5).252(6.4)
1.10(28)
.157 (4)
* General tolerance± .012 (0.3)
0.807(20.5)
1.967 (50)
1.573 (40)
1.181(30)
(2x) .142 (3.6)
.944 (24)
.846(21.5)
Dimensions in inches (mm)
60-BPX-010;-020;-030
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-BPX-010-5-X
60-BPX-020-5-X
60-BPX-030-5-X
60-BPX-060;-100
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-BPX-060-5-X
60-BPX-100-5-X
60-BPX-010;-020;-030
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-BPX-010-5-X
60-BPX-020-5-X
60-BPX-030-5-X
60-BPX-060;-100
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-BPX-060-X-4
60-BPX-100-X-2
60-BPX-060-X-2
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Cur
rent
(%)
Temperature Characteristics
Pow
er E
ntry
Mod
ules
60-BPR & BPS Series
25SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Entry ModulesBolt-in Right Angle Terminals
Features Ideally suited for products that must
conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II
and complies with IEC 950 Uses IEC connector that meets most safety standards PCB mounting types available (see page 54) Length under tab is shortened for small spaces
Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 27)
UL approved low leakage version also available
Applications Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units
Specifications
60-BPF-010-3-20.35mA 2200pF ± 20%
.022uF ± 20%
60-BPF-010-3-4250VAC 1A
.047uF ± 20%6.0mH 30°C
60-BPF-010-5-20.50mA 3300pF ± 20%
.022uF ± 20%
60-BPF-010-5-4 .047uF ± 20%
60-BPF-020-3-20.35mA 2200pF ± 20%
.022uF ± 20%
60-BPF-020-3-4250VAC 2A
.047uF ± 20%2.4mH 30°C
60-BPF-020-5-20.50mA 3300pF ± 20%
.022uF ± 20%
60-BPF-020-5-4 .047uF ± 20%
60-BPF-030-3-20.35mA 2200pF ± 20%
.022uF ± 20%
60-BPF-030-3-4250VAC 3A
.047uF ± 20%1.2mH 30°C
60-BPF-030-5-20.50mA 3300pF ± 20%
.022uF ± 20%
60-BPF-030-5-4 .047uF ± 20%
60-BPF-060-3-20.35mA 2200pF ± 20%
.022uF ± 20%
60-BPF-060-3-4250VAC 6A
.047uF ± 20%0.53mH 45°C
60-BPF-060-5-20.50mA 3300pF ± 20%
.022uF ± 20%
60-BPF-060-5-4 .047uF ± 20%
ModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY CX (L1) Rise (Max.)
Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 50gInput: Compatible with IEC-320
60-BPF Series
1
E
2
3
E
4
CX
CY
CY
L1
Circuit Diagram
Pow
er E
ntry
Mod
ules
26 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Tested and found to beIAW VDE 0565 Part 3.
Power Entry ModulesBolt-in Right Angle Terminals
Common Mode Normal Mode
Dimensions in inches (mm)
1.180 (30)
Panel cutout dimensionsmounts from backside
R4.5
1.180 (30)
.865 (22)
1.573 (40)2- .142 (3.6)
1.967 (50)
1.573 (40)
2- .142 (3.6)
.885(22.5)
1.463 (37.2)
1.317(33.5)
( )
.991(25.2).590 (15)
.142(3.6).059
(1.5)
.047 (1.2)
1.070(27.2)
.232 (5.9)
.708 (18)
.024 (.6)
.031 (.8)
.779(19.8)
* Generaltolerance± .012 (.3)
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
60-BPF-010;-020
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-BPF-010-3-X
60-BPF-020-3-X
60-BPF-030;-060
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-BPF-030-3-X
60-BPF-060-3-X
60-BPF-010;-020
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-BPF-010-X-4
60-BPF-020-X-4
60-BPF-030;-060
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-BPF-030-X-4
60-BPF-060-X-4
60-BPFFast-on Terminals120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Cur
rent
(%)
Temperature Characteristics
60-BPF Series
Pow
er E
ntry
Mod
ules
27SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Features Ideally suited for products that must
conform to FCC part 15 regulations Metal cased miniature filter offers high performance Meets over voltage of IEC 664 category II
and complies with IEC 950 PCB mounting types available (see page 56) PCB mounting minimizes space and provides
economical installation Excellent filtering characteristics for high frequencies Earth coil standard Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 29)
Applications Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units
Power Entry ModulesHigh Frequency Attenuation
Specifications
0.35mA 2200pF ± 20%0.1uF ± 20%
250VAC 1A.047uF ± 20%
6mH 18.3uH 30°C
0.50mA 3300pF ± 20%0.1uF ± 20%
.047uF ± 20%
0.35mA 2200pF ± 20%0.1uF ± 20%
250VAC 2A.047uF ± 20%
2.4mH 18.3uH 30°C
0.50mA 3300pF ± 20%0.1uF ± 20%
.047uF ± 20%
0.35mA 2200pF ± 20%0.1uF ± 20%
250VAC 3A.047uF ± 20%
1.2mH 18.3uH 30°C
0.50mA 3300pF ± 20%0.1uF ± 20%
.047uF ± 20%
0.35mA 2200pF ± 20%0.1uF ± 20%
250VAC 6A.047uF ± 20%
.53mH 18.3uH 45°C
0.50mA 3300pF ± 20%0.1uF ± 20%
.047uF ± 20%
ModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY CX (L1) (L2) Rise (Max.)
Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 50gInput: Compatible with IEC-320
60-BHS Series
60-BHS-010-3-11
60-BHS-010-3-4
60-BHS-010-5-11
60-BHS-010-5-4
60-BHS-020-3-11
60-BHS-020-3-4
60-BHS-020-5-11
60-BHS-020-5-4
60-BHS-030-3-11
60-BHS-030-3-4
60-BHS-030-5-11
60-BHS-030-5-4
60-BHS-060-3-11
60-BHS-060-3-4
60-BHS-060-5-11
60-BHS-060-5-4
1
E
2
3
E
4
CX
CY
CY
L1
L2
Circuit Diagram
Pow
er E
ntry
Mod
ules
28 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Tested and found to beIAW VDE 0565 Part 3.
Common Mode Normal Mode
Dimensions in inches (mm)
1.180 (30)
Panel cutout dimensionsmounts from backside
R4.5
1.180 (30)
.865 (22)
1.573 (40)2- .142 (3.6)
1.967 (50)1.573 (40)
2- .142 (3.6)
.885(22.5)
1.534 (39)1.389(35.3)
.098(2.5)
.031 (.8)
.779(19.8)
1.180 (30)
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Inse
rtio
n Lo
ss (d
B)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
90
60-BHS-060-X-11
60-BHS-030-X-11
60-BHS-020-X-11
60-BHS-010-X-11
Inse
rtio
n Lo
ss (d
B)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
90
60-BHS-060-X-4
60-BHS-030-X-4
60-BHS-020-X-4
60-BHS-010-X-4
Inse
rtio
n Lo
ss (d
B)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
90
60-BHS-060-3-11
60-BHS-030-3-11
60-BHS-010-3-11
60-BHS-020-3-11
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Inse
rtio
n Lo
ss (d
B)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
90
60-BHS-060-3-4
60-BHS-030-3-4
60-BHS-010-3-4
60-BHS-020-3-4
60-BHS-XXX-X-11
60-BHS-XXX-X-4 60-BHS-XXX-3-4
60-BHS-XXX-3-11
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Cur
rent
(%)
Temperature Characteristics
Power Entry ModulesHigh Frequency Attenuation
60-BHS Series
Pow
er E
ntry
Mod
ules
29SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Figure
A
C
A
C
B
A
C
B
A
B
Inductance(L1)
3.0mH
1.5mH
0.5mH
1.5mH
0.5mH
1.5mH
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
30
Pow
er E
ntry
Mod
ules
Power Entry ModulesBolt-in Rear TerminalsFor General Purpose Applications
Specifications
Features Ideally suited for products that must
conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II
and complies with IEC 950 Uses IEC connector that meets most safety standards Operating temperature: -25°C to +70°C Compact configuration
Applications Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units
Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 45gInput: Compatible with IEC-320
10-BPF Series
Circuit Diagram
CX L1CY
CY
CX
3
CX L1CY
CY
CX
2
CX L1CY
CY
1
Model
10-BPF-001-5-A
10-BPF-001-5-C
10-BPF-003-5-A
10-BPF-003-5-C
10-BPF-003-5-D
10-BPF-006-5-A
10-BPF-006-5-C
10-BPF-006-5-D
10-BPF-010-5-A
10-BPF-010-5-D
RatedVoltage
(@ 50/60Hz)
120/250VAC
RatedCurrent
1A
3A
6A
10A
LeakageCurrent(Max.)
0.50mA
CY
3300pF
4700pF
3300pF
3300pF & 0.01uF
3300pF
3300pF & 0.01uF
CX
2200pF
0.01uF
3300pF & 0.01uF
0.01uF
3300pF & 0.01uF
CircuitDiagram
1
2
1
2
1
3
TemperatureRise
(Max.)
30°C
Capacitance
1.25 (32)
2.3 (62)
.13 (3.5 (2X)
1.9 (50)
1.6 (40)
1.1 (27) .07 (2)
1.8 (46)1.9(50)
.80 (20.5)+.01 -0.0
1.1 (28.5)+.01 -0.0
1.6 (40)±.007
M3 (2X)
1.4 (3.5) (2X)
1.2(30)
1.6(40)
.62 (16).82 (21) .25
(6.5)2.0 (51)
1.5 (37.5)
1.1 (28)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
31
10-BPF Series
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Common Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Normal Mode
10-BPF-001;-003
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
10-BPF-001-5-A
10-BPF-001-5-C
10-BPF-003-5-A
10-BPF-003-5-C
10-BPF-006;-010
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
10-BPF-006-5-C
10-BPF-006-5-A
10-BPF-006-5-D
10-BPF-010-5-A
10-BPF-010-5-D
10-BPF-001;-003
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
10-BPF-001-5-A
10-BPF-001-5-C
10-BPF-003-5-A
10-BPF-003-5-C
10-BPF-006;-010
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
10-BPF-006-5-D
10-BPF-006-5-C
10-BPF-006-5-A
10-BPF-010-5-A
10-BPF-010-5-D
Power Entry ModulesBolt-in Rear TerminalsFor General Purpose Applications
1.6(40)
2.0 (52)
M3 (2X)
2.8 (72)
2.0 (52)
1.4 (37)
Figure C
Figure B
Figure A
Dimensions in inches (mm)
Pow
er E
ntry
Mod
ules
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
32
Pow
er E
ntry
Mod
ules
Power Entry ModulesBolt-in Rear TerminalsFor Medical Purpose Applications
Specifications
Features Ideally suited for products that must
conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II
and complies with IEC 950 Uses IEC connector that meets most safety standards Operating temperature: -25°C to +70°C Compact configuration Low leakage current
Applications Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units
Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 45gInput: Compatible with IEC-320
10-BPF Series
Circuit Diagram
1
E
2
3
E
4
CX
L1
Model
10-BPF-001-2-A
10-BPF-003-2-A
10-BPF-006-2-A
RatedVoltage
(@ 50/60Hz)
120/250VAC
RatedCurrent
1A
10A
LeakageCurrent(Max.)
5uA
CapacitanceCX
0.01uF
Inductance(L1)
3.0mH
1.5mH
0.5mH
CircuitDiagram
1
Figure
A
TemperatureRise
(Max.)
30°C
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
33
Power Entry ModulesBolt-in Rear TerminalsFor Medical Purpose Applications
Pow
er E
ntry
Mod
ules
10-BPF Series
0.807(20.5)
Dimensions in inches (mm)
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Common Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Normal Mode
10-BPF-001;-003;-006
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
10-BPF-001-2-A
10-BPF-003-2-A
10-BPF-006-2-A
10-BPF-001;-003;-006
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
10-BPF-001-2-A
10-BPF-003-2-A
10-BPF-006-2-A
1.9(50)
1.6(40)
1.2(30)
.63 (16)
.82 (21) .25(6.5)
2.0 (51)
1.5 (37.5)
1.1 (28)
.80 (20.5)+.01 -0.0
1.1 (28.5)+.01 -0.0
1.6 (40)±.007
M3 (2X)
1.4 (3.5)(2X)
Features Ideally suited for products that must
conform to FCC part 15 regulations Metal cased miniature filter offers high performance Meets over voltage of IEC 664 category II
and complies with IEC 950 Uses IEC connector that meets most safety standards Snap-in style saves labor and hardware inventory Wire output minimizes space and provides
economical installation Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 35)
Applications Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units
Specifications
60-SPL-010-3-20.35mA 2200pF ± 20%
22nF ± 20%
60-SPL-010-3-3250VAC 1A
33nF ± 20%6.0mH 30°C
60-SPL-010-5-20.50mA 3300pF ± 20%
22nF ± 20%
60-SPL-010-5-3 33nF ± 20%
60-SPL-020-3-20.35mA 2200pF ± 20%
22nF ± 20%
60-SPL-020-3-3250VAC 2A
33nF ± 20%2.4mH 30°C
60-SPL-020-5-20.50mA 3300pF ± 20%
22nF ± 20%
60-SPL-020-5-3 33nF ± 20%
60-SPL-030-3-20.35mA
2200pF ± 20%.022uF ± 20%
60-SPL-030-3-3250VAC 3A
3300pF ± 20%1.2mH 30°C
60-SPL-030-5-20.50mA
2200pF ± 20%.033uF ± 20%
60-SPL-030-5-3 3300pF ± 20%
60-SPL-060-3-20.35mA 2200pF ± 20%
22nF ± 20%
60-SPL-060-3-3250VAC 6A
33nF ± 20%0.53mH 45°C
60-SPL-060-5-20.50mA 3300pF ± 20%
22nF ± 20%
60-SPL-060-5-3 33nF ± 20%
ModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY CX (L1) Rise (Max.)
Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 50gInput: Compatible with IEC-320
60-SPL Series
1
E
2
3
E
4
CX
CY
CY
L1
Circuit Diagram
34 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Tested and found to beIAW VDE 0565 Part 3.
Power Entry ModulesSnap-in with Wire Leads
Pow
er E
ntry
Mod
ules
Power Entry ModulesSnap-in with Wire Leads
Common Mode Normal Mode
Dimensions in inches (mm)
1.397(35.5)
.252 (6.4)
1.612 (41)
1.172 (29.8)
4.719 (120)*
.236 (6)
Blue
Green/Yellow
Brown
PVC Insulated wire
UL1617 AWG #22
.963(24.5)
* Metal caseTin Plated
* General tolerance± .012 (.3) .838 (21.3)
R2
W
.853(21.7)
Panel cutout dimensions
T :Panel ThicknessT W
.039 (1.0) 1.270 (32.3)
.047 (1.2) 1.274 (32.4)
.059 (1.5) 1.285 (32.5)
UL 1015 AWG #18
* Custom lengths available upon request.
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
60-SPL-010;-020
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-SPL-020-5-X
60-SPL-010-5-X
60-SPL-020-3-X
60-SPL-010-3-X
60-SPL-030;-060
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-SPL-030-5-X
60-SPL-060-5-X
60-SPL-030-3-X
60-SPL-060-3-X
60-SPL-010;-020
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-SPL-010-X-4
60-SPL-020-X-4
60-SPL-010-X-2
60-SPL-020-X-2
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
60-SPL-030;-060
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-SPL-030-X-4
60-SPL-060-X-4
60-SPL-030-X-2
60-SPL-060-X-2
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Cur
rent
(%)
Temperature Characteristics
60-SPL Series
Pow
er E
ntry
Mod
ules
35SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
36 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
1
E
2
3
E
4
CX
CY
CY
L1
Circuit Diagram
Power Entry ModulesBolt-in with Wire Leads
Features Ideally suited for products that must
conform to FCC part 15 regulations Metal case filter offers high performance Meets over voltage of IEC 664 category II
and complies with IEC 950 Uses IEC connector that meets most safety standards Wire output for minimizing space use
and economical installation Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 37)
Applications Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units
Specifications
60-BPL-010-3-20.35mA 2200pF ± 20%
22nF ± 20%
60-BPL-010-3-3250VAC 1A
33nF ± 20%6.0mH 30°C
60-BPL-010-5-20.50mA 3300pF ± 20%
22nF ± 20%
60-BPL-010-5-3 33nF ± 20%
60-BPL-020-3-20.35mA 2200pF ± 20%
22nF ± 20%
60-BPL-020-3-3250VAC 2A
33nF ± 20%2.4mH 30°C
60-BPL-020-5-20.50mA 3300pF ± 20%
22nF ± 20%
60-BPL-020-5-3 33nF ± 20%
60-BPL-030-3-20.35mA
2200pF ± 20%.022uF ± 20%
60-BPL-030-3-3250VAC 3A
3300pF ± 20%1.2mH 30°C
60-BPL-030-5-20.50mA
2200pF ± 20%.033uF ± 20%
60-BPL-030-5-3 3300pF ± 20%
60-BPL-060-3-20.35mA 2200pF ± 20%
22nF ± 20%
60-BPL-060-3-3250VAC 6A
33nF ± 20%0.53mH 45°C
60-BPL-060-5-20.50mA 3300pF ± 20%
22nF ± 20%
60-BPL-060-5-3 33nF ± 20%
ModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY CX (L1) Rise (Max.)
Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 50gInput: Compatible with IEC-320
60-BPL Series
Pow
er E
ntry
Mod
ules
Tested and found to beIAW VDE 0565 Part 3.
Power Entry ModulesBolt-in with Wire Leads
Common Mode Normal Mode
Dimensions in inches (mm)
1.612 (41)
.252 (6.4)1.172(29.8)
* General tolerance±.012 (0.3)
Panel cutout dimensionsmounts from front side
R3.5
1.239 (31.5)
.885(22.5) .837
(21.3)
1.573 (40)
2- .118 (M3)
Panel cutout dimensionsmounts from back side
R4.5
1.180 (30)
.865 (22)
1.573 (40) 2- .130 (3.3)
1.967 (50)
1.573 (40)
1.160(29.5)
2- .142 (3.6)
.944 (24)
.830(21.1)
4.719 (120)*
BLUE
GREEN/YELLOW
BROWN
PVC Insulated wireUL1617 AWG #22
UL1015 AWG # 18
.236 (6)
* Custom lengths available upon request.
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
60-BPL-010;-020
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-BPL-020-5-X
60-BPL-010-5-X
60-BPL-020-3-X
60-BPL-010-3-X
60-BPL-030;-060
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-BPL-030-5-X
60-BPL-060-5-X
60-BPL-030-3-X
60-BPL-060-3-X
60-BPL-030;-060
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-BPL-030-X-4
60-BPL-060-X-2
60-BPL-030-X-2
60-BPL-060-X-4
60-BPL-010;-020
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-BPL-010-X-4
60-BPL-020-X-4
60-BPL-010-X-2
60-BPL-020-X-2
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Cur
rent
(%)
Temperature Characteristics
60-BPL Series
Pow
er E
ntry
Mod
ules
37SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
38
1
E
2
3
E
4
CX
CY
CY
L1
Circuit Diagram
Power Entry ModulesBolt-in with Wire Leads
Features Ideally suited for products that must
conform to FCC part 15 regulations Metal case filter offers high performance Meets over voltage of IEC 664 category II
and complies with IEC 950 Uses IEC connector that meets most safety standards Wire output for minimizing space use
and economical installation Operating temperature: -25°C to +70°C Compact configuration
Applications Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units
Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 50gInput: Compatible with IEC-320
10-BPL Series
Pow
er E
ntry
Mod
ules
Specifications
Model
10-BPL-001-5-B
10-BPL-003-5-B
10-BPL-006-5-B
RatedVoltage
(@ 50/60Hz)
250VAC
RatedCurrent
1A
3A
6A
LeakageCurrent(Max.)
0.50mA
CY
3300pF
CX
0.01uF
Inductance(L1)
3.0mH
1.5mH
0.5mH
CircuitDiagram
1
Figure
A
TemperatureRise
(Max.)
30°C
Capacitance
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
39
Power Entry ModulesBolt-in with Wire Leads
Dimensions in inches (mm)
10-BPL Series
Pow
er E
ntry
Mod
ules
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Common Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Normal Mode
10-BPL-001;-003;-006
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
10-BPL-001-5-B
10-BPL-006-5-B
10-BPL-003-5-B
10-BPL-001;-003;-006
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
10-BPL-001-5-B
10-BPL-006-5-B
10-BPL-003-5-B
1.9(50)
1.6(40)
1.2(30)
1.4 (3.5)(2X)
.63 (16)
.82 (21) .25(6.5)
2.0 (51)
1.5 (37.5)
1.1 (28)
.80 (20.5)+.01 -0.0
1.1 (28.5)+.01 -0.0
1.6 (40)±.007
M3 (2X)
Figure A
Power Entry ModulesSnap-in Mount
Features Ideally suited for products that must
conform to FCC part 15 regulations Metal cased miniature filter offers high performance Meets over voltage of IEC 664 category II
and complies with IEC 950 Uses IEC connector that meets most safety standards Snap-in style saves labor and hardware inventory Solder lug and fast-on tab terminations available Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 41) UL approved low leakage version also available
Applications Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units
Specifications
60-XXX-010-3-20.35mA 2200pF ± 20%
.022uF ± 20%
60-XXX-010-3-4250VAC 1A
.047uF ± 20%6.0mH 30°C
60-XXX-010-5-20.50mA 3300pF ± 20%
.022uF ± 20%
60-XXX-010-5-4 .047uF ± 20%
60-XXX-020-3-20.35mA 2200pF ± 20%
.022uF ± 20%
60-XXX-020-3-4250VAC 2A
.047uF ± 20%2.4mH 30°C
60-XXX-020-5-20.50mA 3300pF ± 20%
.022uF ± 20%
60-XXX-020-5-4 .047uF ± 20%
60-XXX-030-3-20.35mA 2200pF ± 20%
.022uF ± 20%
60-XXX-030-3-4250VAC 3A
.047uF ± 20%1.2mH 30°C
60-XXX-030-5-20.50mA 3300pF ± 20%
.022uF ± 20%
60-XXX-030-5-4 .047uF ± 20%
60-XXX-060-3-20.35mA 2200pF ± 20%
.022uF ± 20%
60-XXX-060-3-4250VAC 6A
.047uF ± 20%0.53mH 45°C
60-XXX-060-5-20.50mA 3300pF ± 20%
.022uF ± 20%
60-XXX-060-5-4 .047uF ± 20%
Model*Rated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY CX (L1) Rise (Max.)
Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 45gInput: Compatible with IEC-320
60-SPR & SPS Series
* Substitute SPR or SPS for XXX60-SPR - Fast-on terminals60-SPS - Solder lug terminals
60-XXX-100-3-2250VAC 10A
0.35mA 2200pF ± 20%.022uF ± 20% 0.26mH 45°C
60-XXX-100-5-2 0.50mA 3300pF ± 20%
1
E
2
3
E
4
CX
CY
CY
L1
Circuit Diagram
Pow
er E
ntry
Mod
ules
40 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Tested and found to beIAW VDE 0565 Part 3.
60-SPR-150-3-11 250VAC 15A 0.35mA 2200pF ± 20% .01uF ± 20% 0.15mH 45°C
Power Entry ModulesSnap-in Mount
Common Mode Normal Mode
1.395(35.5)
2.033 (51.7)
1.805 (45.9)
1.418 (35.9).252 (6.4)
1.172(29.8)
.157 (4)
Solder Lug
2 X 3 hole
* Standard terminalFast-on tab #250available asSPR series2.096 (53.3)
* General tolerance± .012 (0.3)
Panel cutout dimensionsfor 1.0t chassis
R2
.853(21.7)
.837(21.3)
.963(24.5)
W
Panel cutout dimensions
T: Panel ThicknessT W
.039 (1.0) 1.270 (32.3)
.047 (1.2) 1.274 (32.4)
.059 (1.5) 1.285 (32.5)
Solder lugs shown. Also available in fast-ons.
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
60-SPX-010;-020;-030
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-SPX-010-5-X
60-SPX-020-5-X
60-SPX-030-5-X
60-SPX-060;-100
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-SPX-60-5-X
60-SPX-100-5-X
60-SPX-060;-100
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-SPX-060-X-4
60-SPX-100-X-2
60-SPX-060-X-2
60-SPX-010;-020;-030
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-SPX-010-X-4
60-SPX-030-X-4
60-SPX-020-X-4
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Cur
rent
(%)
Temperature Characteristics
60-SPR & SPS Series
Pow
er E
ntry
Mod
ules
41SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Dimensions in inches (mm)
Features North American and Metric fuse
holders available Fuse holder provides effective EMI suppression
of common and differential mode Suitable for products that must conform
to FCC and FTZ requirements Meets over voltage category II of IEC 664
and complies with IEC 950 Fast-on terminals or solder lug terminals Metal case provides effective EMI shielding Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 43)
Applications Computers and peripheral equipment Electronic equipment Digital equipment Measuring and testing instruments Telecommunications equipment
Model*Rated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY CX (L1) Rise (Max.)
Note: Test Voltage 1500VAC one minute, line to groundInsulation Resistance: 300 MΩ min. at 500VDCF(S) = Fast-on or (Solder lug terminals)
Voltage Drop: 1V max. at rated currentWeight: 78gInlet: Compatible with IEC-320
Specifications
64-XXX-020-3-11 0.35mA0.50mA
2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%
0.35mA0.50mA0.35mA0.50mA0.35mA0.50mA0.35mA0.50mA0.35mA0.50mA0.20mA0.25mA0.20mA0.25mA0.20mA0.25mA0.20mA0.25mA0.20mA0.25mA0.20mA0.25mA
64-XXX-020-5-11250VAC 2A
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
4A
6A
40°C
45°C
45°C
40°C
45°C
45°C
6.5mH
4.2mH
1.6mH
6.5mH
4.2mH
1.6mH
2A
4A
6A
250VAC
250VAC
125VAC
125VAC
125VAC
64-XXX-020-3-1264-XXX-020-5-1264-XXX-040-3-1164-XXX-040-5-1164-XXX-040-3-1264-XXX-040-5-1264-XXX-060-3-1164-XXX-060-5-1164-XXX-060-3-1264-XXX-060-5-1265-XXX-020-3-1165-XXX-020-5-1165-XXX-020-3-1265-XXX-020-5-1265-XXX-040-3-1165-XXX-040-5-1165-XXX-040-3-1265-XXX-040-5-1265-XXX-060-3-1165-XXX-060-5-1165-XXX-060-3-1265-XXX-060-5-12
Fused Filtered Power Entry ModulesFor General Purpose Applications
Circuit Diagram
L
N
L
N
E E
L1
R CX
CY
CY
Fuse
d Fi
lter
ed
Pow
er E
ntry
Mod
ules
42 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Tested and found to beIAW VDE 0565 Part 3.
* Substitute BFF or BFS for XXXBFF - Fast-on terminalsBFS - Solder lug terminals
64-65-BFF/64-65-BFS Series
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Common Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Normal Mode
Dimensions in inches (mm)
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
90
2 Amp
6 Amp
4 Amp
0.35 mA Leakage Versions
0.50 mA Leakage Versions
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
90
2 Amp
6 Amp
4 Amp
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
00.1 0.2 0.5 1 2 5 10 20 50
90
2 Amp
4 Amp
6 Amp
10
0.50 mA Leakage Versions
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
00.1 0.2 0.5 1 2 5 10 20 50
90
2 Amp
4 Amp6 Amp
10
0.35 mA Leakage Versions
Fuse cover
1.376 (35)
1.298 (33) 2 - .13
(2 - 3.3 )Hole
1.738 (44.2)
1.416±.008(36±0.2)
1.101 (28)
1.616 (41.1) 1.14(29)
1.29 (32.8)
Fast-on tab#250t= .031 (0.8)
2.32 (59)
.098 (2.5)
0.252 (6.4)
* General Tolerance:±.020 (0.5)
* Metal Case
+0.2 -0.1
0.158 (4.0)
2.249 (L:57.2)
+.008 -.004
* Alternate Terminal for 64/65-BFS-Solder Lug Terminal
Fused Filtered Power Entry ModulesFor General Purpose Applications
Dimensions64/65-BFF Series
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Cur
rent
(%)
Temperature Characteristics
64-65-BFF/64-65-BFS Series
Fuse
d Fi
lter
edPo
wer
Ent
ry M
odul
es
43SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Applications Medical equipment Electronic equipment Digital equipment Industrial equipment
Features Metric and North American fuse
holders available Fuse holder provides effective EMI suppression
of common and differential mode Suitable for products that must conform
to FCC and FTZ requirements Meets over voltage category II of IEC 664
and complies with IEC 950 Fast-on terminations or solder lug terminations Metal case provides effective EMI shielding Provides susceptibility protection without the leakage
current associated with line-to-ground capacitance Reduces the line to ground capacitance in order
to meet patient care requirements Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 45)
Telecommunications equipment Measuring and testing instruments Personal computers
and peripherals
Fused Filtered Power Entry ModulesFor Medical or General Purpose Applications
L
N
L
N
E E
L
N
L
N
E E
LIN
E
LOA
D
LIN
E
LOA
DR CX
L1
R CX
L1 CY
CY
Circuit Diagrams66/67-BFF(S)-XXX-1-X Filter
66/67-BFF(S)-XXX-0-X and66/67-BFF(S)-XXX-4-X FiltersFu
sed
Filt
ered
Pow
er E
ntry
Mod
ules
44 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Tested and found to beIAW VDE 0565 Part 3.
Model*Rated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY CX (L1) Rise (Max.)
Specifications
Note: Test Voltage 1500VAC one minute, line to groundInsulation Resistance: 300 MΩ min. at 500VDCF(S) = Fast-on or (Solder lug terminals)
Voltage Drop: 1V max. at rated currentWeight: 78gInlet: Compatible with IEC-320
* Substitute BFF or BFS for XXXBFF - Fast-on terminalsBFS - Solder lug terminals
66-XXX-020-1-1166-XXX-020-1-1266-XXX-020-0-1166-XXX-020-4-1166-XXX-020-0-1266-XXX-020-4-1266-XXX-040-1-1166-XXX-040-1-1266-XXX-040-0-1166-XXX-040-4-1166-XXX-040-0-1266-XXX-040-4-1266-XXX-060-1-1166-XXX-060-1-1266-XXX-060-0-1166-XXX-060-4-1166-XXX-060-0-1266-XXX-060-4-1267-XXX-020-1-1167-XXX-020-1-1267-XXX-020-0-1167-XXX-020-4-1167-XXX-020-0-1267-XXX-020-4-1267-XXX-040-1-1167-XXX-040-1-1267-XXX-040-0-1167-XXX-040-4-1167-XXX-040-0-1267-XXX-040-4-1267-XXX-060-1-1167-XXX-060-1-1267-XXX-060-0-1167-XXX-060-4-1167-XXX-060-0-1267-XXX-060-4-12
250VAC 2A 40°C6.5mH
4.2mH
1.6mH
6.5mH
4.2mH
1.6mH
45°C
45°C
40°C
45°C
45°C
0.01mA none
none
none
none
none
none
0.1mA
0.1mA
0.075mA0.22uF0.1uF
0.1uF
0.22uF
0.22uF0.1uF
0.1uF
0.22uF
0.22uF0.1uF
0.1uF
0.22uF
0.22uF0.1uF
0.1uF
0.22uF
0.22uF0.1uF
0.1uF
0.22uF
0.22uF0.1uF
0.1uF
0.22uF
330pF ± 20%470pF ± 20%330pF ± 20%470pF ± 20%
330pF ± 20%470pF ± 20%330pF ± 20%470pF ± 20%
330pF ± 20%470pF ± 20%330pF ± 20%470pF ± 20%
330pF ± 20%470pF ± 20%330pF ± 20%470pF ± 20%
330pF ± 20%470pF ± 20%330pF ± 20%470pF ± 20%
330pF ± 20%470pF ± 20%330pF ± 20%470pF ± 20%
0.075mA
0.01mA
0.1mA
0.1mA
0.075mA
0.075mA
0.01mA
0.1mA
0.1mA
0.075mA
0.075mA
0.005mA
0.05mA
0.05mA
0.035mA
0.035mA
0.005mA
0.05mA
0.05mA
0.035mA
0.035mA
0.005mA
0.05mA
0.05mA
0.035mA
0.035mA
4A
6A
2A
4A
6A
250VAC
250VAC
125VAC
125VAC
125VAC
66-67-BFF/66-67-BFS Series
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
0.075 and 0.1 mA Leakage Current
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
90
2 Amp
6 Amp4 Amp
0.075 and 0.1 mA Leakage Current
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
90
2 Amp
6 Amp
4 Amp
Fused Filtered Power Entry ModulesFor Medical or General Purpose Applications
Common Mode Normal Mode
Dimensions in inches (mm)
0.01 mA Leakage Current
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
90
2 Amp
6 Amp4 Amp
0.01 mA Leakage Current
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
90
2 Amp
6 Amp
4 Amp
Fuse cover
1.376 (35)
1.298 (33) 2 - .13
(2 - 3.3 )Hole
1.738 (44.2)
1.416±.008(36±0.2)
1.101 (28)
1.616 (41.1) 1.14(29)
1.29 (32.8)
Fast-on tab#250t= .031 (0.8)
2.32 (59)
.098 (2.5)
0.252 (6.4)
* General Tolerance:±.020 (0.5)
* Metal Case
+0.2 -0.1
0.158 (4.0)
2.249 (L:57.2)
+.008 -.004
* Alternate Terminal for 66/67-BFS-Solder Lug Terminal
Dimensions66-67-BFF/66-67-BFS Series
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Cur
rent
(%)
66-67-BFF/66-67-BFS Series
Temperature Characteristics
Fuse
d Fi
lter
edPo
wer
Ent
ry M
odul
es
45SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Circuit DiagramL
N
L
N
E ERCX
CY
CY
CX
Features North American and Metric fuse
holders available Fuse holder and double pole power ON/OFF switch
provided in a convenient/compact package Suitable for products that must conform
to FCC and FTZ requirements Meets over voltage category II of IEC 664
and complies with IEC 950 Metal case provides effective EMI shielding Easy access fuse drawer with space for spare fuse Flange-mounted or snap-in styles available
for quick mounting Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 47)
Switched and Fused FilteredPower Entry ModulesFor General Purpose Applications
Swit
ched
and
Fus
ed F
ilte
red
Pow
er E
ntry
Mod
ules
46 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Tested and found to beIAW VDE 0565 Part 3.
Applications Computers and
peripheral equipment Electronic equipment
Digital equipment Measuring and testing instruments Telecommunications equipment
Note: Test Voltage 1500VAC one minute, line to groundInsulation Resistance: 300 MΩ min. at 500VDCB(S) = Bolt-in terminals or (Snap-in terminals)
Voltage Drop: 1V max. at rated currentWeight: 130gInlet: Compatible with IEC-320
* Substitute BSF or SSF for XXXBSF - Bolt-in switched and fusedSSF - Snap-in switched and fused
SpecificationsModel*
Rated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY CX1 CX2 (L1) Rise (Max.)
64-XXX-020-3-1264-XXX-020-3-0464-XXX-020-3-1464-XXX-020-3-0664-XXX-020-5-1264-XXX-020-5-0464-XXX-020-5-1464-XXX-020-5-0664-XXX-040-3-1264-XXX-040-3-0464-XXX-040-3-1464-XXX-040-3-0664-XXX-040-5-1264-XXX-040-5-0464-XXX-040-5-1464-XXX-040-5-0664-XXX-060-3-1264-XXX-060-3-0464-XXX-060-3-1464-XXX-060-3-0664-XXX-060-5-1264-XXX-060-5-0464-XXX-060-5-1464-XXX-060-5-0665-XXX-020-3-1265-XXX-020-3-0465-XXX-020-3-1465-XXX-020-3-0665-XXX-020-5-1265-XXX-020-5-0465-XXX-020-5-1465-XXX-020-5-0665-XXX-040-3-1265-XXX-040-3-0465-XXX-040-3-1465-XXX-040-3-0665-XXX-040-5-1265-XXX-040-5-0465-XXX-040-5-1465-XXX-040-5-0665-XXX-060-3-1265-XXX-060-3-0465-XXX-060-3-1465-XXX-060-3-0665-XXX-060-5-1265-XXX-060-5-0465-XXX-060-5-1465-XXX-060-5-06
250VAC
250VAC
250VAC
125VAC
125VAC
125VAC
2A 45°C10.5mH
10.5mH
4.2mH
4.2mH
1.6mH
1.6mH
45°C
45°C
45°C
45°C
45°C
0.35mA 2200pF
3300pF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
2200pF
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
4A
6A
NONE0.22uFNONE0.47uFNONE0.22uFNONE0.47uFNONE0.22uFNONE0.47uFNONE0.22uFNONE0.47uFNONE0.22uFNONE0.47uFNONE0.22uFNONE0.47uFNONE0.22uFNONE0.47uFNONE0.22uFNONE0.47uFNONE0.22uFNONE0.47uFNONE0.22uFNONE0.47uFNONE0.22uFNONE0.47uFNONE0.22uFNONE0.47uF
2A
4A
6A
64-65-BSF/64-65-SSF Series
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Common Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Normal Mode
.248(6.3)
2.556 (65)
2.348 (59.7)
1.313 (33.4)1.101 (28)
Fast-on tab #250
2.273 (57.8)
1.133(28.8)
2.340 (59.5)
Panel cutout dimensionmount from back side
1.514 (38.8)
A
R .079(2.0)
Thickness of Panel A.031 (0.8t) 2.430 (61.8±0.1).039 (1.0t) 2.446 (62.2±0.1).047 (1.2t) 2.462 (62.6±0.1).059 (1.5t) 2.470 (62.8±0.1).071 (1.8t) 2.473 (62.9±0.1).079 (2.0t) 2.477 (63.0±0.1)
* General Tolerance± .039 (1.0)
* Metal Case
1.16(29.5 )+0.5
-0
+.02-0
t= .031 (0.8)
Dimensions in inches (mm)
0.35 mA Leakage Versions
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
2 Amp
4 Amp
6 Amp
90
0.50 mA Leakage Versions
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
2 Amp
4 Amp
6 Amp
90
64/65-B(S)SF-*-*-02(04,06)
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
00.1 0.2 0.5 1 2 5 10 20 50
6 Amp
90
100
4 Amp
2 Amp
64/65-B(S)SF-*-*-11(12,14)
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
00.1 0.2 0.5 1 2 5 10 20 50
6 Amp
90
100
4 Amp
2 Amp
.248(6.3)
2.556 (65)
2.348 (59.7) Ø.142
(3.6)
1.947 (49.5)
1.573 (40±0.2)
1.101 (28)
Fast-on Tab #250
2.273 (57.8) 1.133(28.8)
2.340(59.5)
1.573 (40.±0.2)
2.399 (61)
Panel cutoutdimensionmount fromback side
R .059(1.5)
2 - .142(3.6) Hole
1.526 (38.8)
1.16±(29.5± )0.5
0
.3340
t= .031 (0.8)
Switched and Fused FilteredPower Entry ModulesFor General Purpose Applications
64/65-SSF SeriesDimensions64/65-BSF Series
Temperature Characteristics
Swit
ched
and
Fus
ed F
ilte
red
Pow
er E
ntry
Mod
ules
47SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Curr
ent (
%)
Temperature Characteristics
L
N
L
N
E E
CY1
CY2
LIN
E
LOA
D
RCX1
L1CX2
Note: CY1 and CY2 capacitorsomitted on 66/67 B(S)F-XXX-1-X Filters
Circuit Diagram
Weight: 130gInlet: Compatible with IEC-320 B(S) = Bolt-in terminals or (Snap-in terminals)
* Substitute BSF or SSF for XXXBSF - Bolt-In Switched and FusedSSF - Snap-In Switched and Fused
Features Metric and North American fuse holders available Fuse holder and a double pole power ON/OFF switch
provides a convenient/compact package Suitable for products that must conform
to FCC and FTZ requirements Meets over voltage category II of IEC 664
and complies with IEC 950 Provides susceptibility protection without the leakage
current associated with line-to-ground capacitors Designed to meet requirements for non-patient
and patient care equipment Metal case provides effective EMI shielding Easy access fuse drawer - space for spare fuse Flange-mounted or snap-in styles available
for quick mounting Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 49)
Applications Medical equipment Industrial equipment Telecommunications equipment Measuring and testing instruments
Digital equipment (including switching power supplies)
General purpose filter forsusceptibility or high frequency“clean up” applications
Switched and Fused Filtered Power Entry ModulesFor Medical or General Purpose Applications
48 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
10.5mH
4.2mH
1.6mH
2A
4A
6A
125VAC
40°C
45°C
67-XXX-020-0-1267-XXX-020-0-0467-XXX-020-0-1467-XXX-020-0-0667-XXX-020-1-1267-XXX-020-1-0467-XXX-020-1-1467-XXX-020-1-0667-XXX-020-4-1267-XXX-020-4-0467-XXX-020-4-1467-XXX-020-4-0667-XXX-040-0-1267-XXX-040-0-0467-XXX-040-0-1467-XXX-040-0-0667-XXX-040-1-1267-XXX-040-1-0467-XXX-040-1-1467-XXX-040-1-0667-XXX-040-4-1267-XXX-040-4-0467-XXX-040-4-1467-XXX-040-4-0667-XXX-060-0-1267-XXX-060-0-0467-XXX-060-0-1467-XXX-060-0-0667-XXX-060-1-1267-XXX-060-1-0467-XXX-060-1-1467-XXX-060-1-0667-XXX-060-4-1267-XXX-060-4-0467-XXX-060-4-1467-XXX-060-4-06
NONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uF
Note: Test Voltage: 1500VAC one minute, line to groundInsulation Resistance: 300 MΩ min. at 500VDCVoltage Drop: 1V max. at rated current
Rated Rated Leakage Temp.Model* Voltage Current Current Capacitance Induct. Rise
50/60Hz (Max.) CY CX1 CX2 (L1) (Max.)
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
330pF
NONE
470pF
330pF
NONE
470pF
330pF
NONE
470pF
0.04mA
.005mA
0.05mA
0.04mA
.005mA
0.05mA
0.04mA
.005mA
0.05mA
Specifications
10.5mH
4.2mH
1.6mH
2A
4A
6A
250VAC
40°C
45°C
66-XXX-020-0-1266-XXX-020-0-0466-XXX-020-0-1466-XXX-020-0-0666-XXX-020-1-1266-XXX-020-1-0466-XXX-020-1-1466-XXX-020-1-0666-XXX-020-4-1266-XXX-020-4-0466-XXX-020-4-1466-XXX-020-4-0666-XXX-040-0-1266-XXX-040-0-0466-XXX-040-0-1466-XXX-040-0-0666-XXX-040-1-1266-XXX-040-1-0466-XXX-040-1-1466-XXX-040-1-0666-XXX-040-4-1266-XXX-040-4-0466-XXX-040-4-1466-XXX-040-4-0666-XXX-060-0-1266-XXX-060-0-0466-XXX-060-0-1466-XXX-060-0-0666-XXX-060-1-1266-XXX-060-1-0466-XXX-060-1-1466-XXX-060-1-0666-XXX-060-4-1266-XXX-060-4-0466-XXX-060-4-1466-XXX-060-4-06
NONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uF
Rated Rated Leakage Temp.Model* Voltage Current Current Capacitance Induct. Rise
50/60Hz (Max.) CY CX1 CX2 (L1) (Max.)
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
330pF
NONE
470pF
330pF
NONE
470pF
330pF
NONE
470pF
.075mA
.01mA
0.1mA
.075mA
.01mA
.01mA
.075mA
.01mA
0.1mA
Tested and found to beIAW VDE 0565 Part 3
Swit
ched
and
Fus
ed F
ilte
red
Pow
er E
ntry
Mod
ules
66-67-BSF/66-67-SSF Series
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
0.075 and 0.1 mA Leakage Current
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
90
2 Amp
6 Amp4 Amp
0.075 and 0.1 mA Leakage Current
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
90
2 Amp
6 Amp
4 Amp
Switched and Fused Filtered Power Entry ModulesFor Medical or General Purpose Applications
Common Mode Normal Mode
0.01 mA Leakage Current
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
90
2 Amp
6 Amp4 Amp
0.01 mA Leakage Current
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
90
2 Amp
6 Amp
4 Amp
Dimensions
.248(6.3)
2.556 (65)
2.348 (59.7)
1.313 (33.4)1.101 (28)
Fast-on tab #250
2.273 (57.8)
1.133(28.8)
2.340 (59.5)
Panel cutout dimensionmount from back side
1.514 (38.8)
A
R .079(2.0)
Thickness of Panel A.031 (0.8t) 2.430 (61.8±0.1).039 (1.0t) 2.446 (62.2±0.1).047 (1.2t) 2.462 (62.6±0.1).059 (1.5t) 2.470 (62.8±0.1).071 (1.8t) 2.473 (62.9±0.1).079 (2.0t) 2.477 (63.0±0.1)
* General Tolerance± .039 (1.0)
* Metal Case
1.16(29.5 )+0.5
-0
+.02-0
t= .031 (0.8)
.248(6.3)
2.556 (65)
2.348 (59.7) Ø.142
(3.6)
1.947 (49.5)
1.573 (40±0.2)
1.101 (28)
Fast-on Tab #250
2.273 (57.8) 1.133(28.8)
2.340(59.5)
1.573 (40.±0.2)
2.399 (61)
Panel cutoutdimensionmount fromback side
R .059(1.5)
2 - .142(3.6) Hole
1.526 (38.8)
1.16(29.5 )+0.5
-0
+.02-0
t= .031 (0.8)
66/67-BSF Series 66/67-SSF Series
Dimensions in inches (mm)
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Curr
ent (
%)
Temperature Characteristics
49SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Swit
ched
and
Fus
ed F
ilte
red
Pow
er E
ntry
Mod
ules
Features Dual fuse for European applications Fuse holder and double pole power ON/OFF switch
provides a convenient/compact package Suitable for products that must conform
to FCC and FTZ requirements Meets over voltage category II of IEC 664
and complies with IEC 950 Metal case provides effective EMI shielding IEC connector meets the safety standards of most
certifying agencies Easy access fuse drawer Flange-mounted UL, CSA, and SEMKO approved Designed to be in accordance with VDE 0565, part 3 Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 51)
Applications Computers and peripheral equipment Electronic equipment Digital equipment Measuring and testing instruments Telecommunications equipment
Switched and Fused Filtered Power Entry ModulesDual Fuse for European Applications
Note: Test Voltage 1500VAC one minute, line to groundInsulation Resistance: 300 MΩ min. at 500VDCVoltage Drop: 1V max. at rated currentWeight: 130gInlet: Compatible with IEC-320 B(S) = Bolt-in terminals or (Snap-in terminals)
L
N
L
N
E E
CY1
CY2
CX2
L1
L2
CX1R1
SW
FUSE
Circuit Diagram
50 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Specifications
68-BSF-020-3-012A
0.1uF 0.1uF10.5mH
68-BSF-020-3-04 0.22uF 0.22uF
68-BSF-040-3-01250VAC 4A 0.35mA 2200pF 2200pF
0.1uF 0.1uF4.2mH 45°C
68-BSF-040-3-04 0.22uF 0.22uF
68-BSF-060-3-016A
0.1uF 0.1uF1.6mH
68-BSF-060-3-04 0.22uF 0.22uF
ModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY1 CY2 CX1 CX2 (L1) Rise (Max.)
Swit
ched
and
Fus
ed F
ilte
red
Pow
er E
ntry
Mod
ules
68-BSF Series
Switched and Fused Filtered Power Entry ModulesDual Fuse for European Applications
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Cur
rent
(%)
Temperature Characteristics.248(6.3)
2.556 (65)
2.348 (59.7) Ø.142
(3.6)
1.947 (49.5)
1.573 (40±0.2)
1.101 (28)
Fast-on Tab #250
2.273 (57.8) 1.133(28.8)
2.340(59.5)
1.573 (40.±0.2)
2.399 (61)
Panel cutoutdimensionmount fromback side
R .059(1.5)
2 - .142(3.6) Hole
1.526 (38.8)
1.16(29.5 )+0.5
-0
+.02-0
t= .031 (0.8)
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Common Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Normal Mode
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
2 Amp4 Amp
6 Amp
90
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
00.1 0.2 0.5 1 2 5 10 20 50
6 Amp
90
100
4 Amp
2 Amp
Dimensions in inches (mm)
Swit
ched
and
Fus
ed F
ilte
red
Pow
er E
ntry
Mod
ules
51SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
68-BSF Series
PCB
Pow
er F
ilte
rs
PCB Power FiltersMiniature Printed Circuit Board
Features Miniature general purpose PCB mounted filter Requires minimal PCB real estate space Low cost Designed for two wire cord systems For three wire cord systems, Y capacitors
can be attached externally Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 53)
Applications Personal computers and peripherals Digital equipment Measuring instruments and medical equipment TV & VCR monitors and display units Home appliances
Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 17.5g
61-MPC Series
1 3
2 4
L1
CX1 CX1
Circuit Diagram
52 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Specifications
61-MPC-010-1-11 1A 11mH
61-MPC-016-1-11250VAC
1.6A0.1mA 0.01uF 0.01uF
6.0mH40°C
61-MPC-025-1-11 2.5A 2.4mH
61-MPC-036-1-11 3.6A 1.2mH
ModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CX1 CX2 (L1) Rise (Max.)
Tested and found to beIAW VDE 0565 Part 3
PCB
Pow
er F
ilte
rs
61-MPC Series
PCB Power FiltersMiniature Printed Circuit Board
Common Mode
Normal Mode
Dimensions in inches (mm)
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
61-MPC
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
61-MPC-010-1-11
61-MPC-036-1-11
61-MPC-025-1-11
61-MPC-016-1-11
Y Cap2 X 3300pF
61-MPC
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
61-MPC-036-1-11
61-MPC-025-1-11
61-MPC-016-1-11
61-MPC-010-1-11
61-MPC
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
61-MPC-036-1-11
61-MPC-010-1-11
61-MPC-025-1-11
61-MPC-016-1-11
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
1 2
3 4
.767 (19.5)
1.239 (31.5)
.767 (19.5)
.059 (1.5)
.354 (9)
4 — .031 (.8)
.551 (14)
.590 (15)
Commonmode withY cap.(Test circuit 1)
(Test circuit 2)
(Test circuit 3)
120
100
80
60
40
20
030 40 50 60 70 80 90
Ambient Temperature (°C)
Cur
rent
(%)
0 100
Temperature Characteristics
53SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Features Ideally suited for products that must
conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II
and complies with IEC 950 Uses IEC connector that meets most safety standards
Solder lug, Fast-on tab styles available (see page 26) PCB mounting style minimizes space and provides
economical installation Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 55) UL approved low leakage version also available
Applications Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units
Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 50gInput: Compatible with IEC-320
60-BPP Series
1
E
2
3
E
4
CX
CY
CY
L1
Circuit Diagram
Power Entry ModulesBolt-in Right Angle Terminalsfor PCB Applications
PCB
Pow
er F
ilte
rs
54 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Specifications
60-BPP-010-3-2 0.35mA 2200pF0.022uF
60-BPP-010-3-4 1A0.047uF
6.0mH60-BPP-010-5-2 0.50mA 3300pF
0.022uF
60-BPP-010-5-4 0.047uF
60-BPP-020-3-2 0.35mA 2200pF0.022uF
60-BPP-020-3-4 2A0.047uF
2.4mH 30°C60-BPP-020-5-2 0.50mA 3300pF
0.022uF
60-BPP-020-5-4 0.047uF
60-BPP-030-3-2 0.35mA 2200pF0.022uF
60-BPP-030-3-4 3A0.047uF
1.2mH60-BPP-030-5-2 0.50mA 3300pF
0.022uF
60-BPP-030-5-4 0.047uF
60-BPP-060-3-2 0.35mA 2200pF0.022uF
60-BPP-060-3-4 6A0.047uF
0.53mH 45°C60-BPP-060-5-2 0.50mA 3300pF
0.022uF
60-BPP-060-5-4 0.047uF
ModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY CX (L1) Rise (Max.)
250VAC
Tested and found to beIAW VDE 0565 Part 3
Common Mode Normal Mode
Dimensions in inches (mm)
1.180 (30)
Panel cutout dimensionsmounts from backside
R4.5
1.180 (30)
.865 (22)
1.573 (40)2- .142 (3.6)
1.967 (50)
1.573 (40)
2- .142 (3.6)
.885(22.5)
1.463 (37.2)
1.317(33.5)
.098 (2.5)
.991(25.2).590 (15)
.142(3.6).059
(1.5)
.047 (1.2)
1.070(27.2)
.232 (5.9)
.708 (18)
.024 (.6)
.031 (.8)
.779(19.8)
* Generaltolerance± .012 (.3)
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
60-BPP-010;-020
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-BPP-010-3-X
60-BPP-020-3-X
60-BPP-030;-060
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-BPP-030-3-X
60-BPP-060-3-X
60-BPP-010;-020
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-BPP-010-X-4
60-BPP-020-X-4
60-BPP-030;-060
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
60-BPP-030-X-4
60-BPP-060-X-4
60-BPPPCBMountingType
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Cur
rent
(%)
Temperature Characteristics
60-BPP Series
Power Entry ModulesBolt-in Right Angle Terminalsfor PCB Applications
PCB
Pow
er F
ilte
rs
55SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Features Ideally suited for products that must
conform to FCC part 15 regulations Metal cased filter offers high performance Meets over voltage of IEC 664 category II
and complies with IEC 950 Solder lug, Fast-on tab styles available (see page 28) PCB mounting minimizes space and provides
economical installation Excellent filtering characteristics for high frequencies Earth coil standard Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 57)
Applications Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units
Power Entry ModulesHigh Frequency AttenuationBolt-in for PCB Applications
Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 50gInput: Compatible with IEC-320
60-BHP Series
1
E
2
3
E
4
CX
CY
CY
L1
L2
Circuit Diagram
PCB
Pow
er F
ilte
rs
56 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Specifications
60-BHP-010-3-110.35mA 2200pF±20%
0.1uF±20%
60-BHP-010-3-41A
.047uF±20%6mH
60-BHP-010-5-110.50mA 3300pF±20%
0.1uF±20%
60-BHP-010-5-4 .047uF±20%
60-BHP-020-3-110.35mA 2200pF±20%
0.1uF±20%
60-BHP-020-3-42A
.047uF±20%2.4mH 30°C
60-BHP-020-5-110.50mA 3300pF±20%
0.1uF±20%
60-BHP-020-5-4 .047uF±20%
60-BHP-030-3-110.35mA 2200pF±20%
0.1uF±20%
60-BHP-030-3-43A
.047uF±20%1.2mH
60-BHP-030-5-110.50mA 3300pF±20%
0.1uF±20%
60-BHP-030-5-4 .047uF±20%
60-BHP-060-3-110.35mA 2200pF±20%
0.1uF±20%
60-BHP-060-3-46A
.047uF±20%0.53mH 45°C
60-BHP-060-5-110.50mA 3300pF±20%
0.1uF±20%
60-BHP-060-5-4 .047uF±20%
ModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY CX (L1) (L2) Rise (Max.)
18.3 uH250VAC
Tested and found to beIAW VDE 0565 Part 3
Common Mode Normal Mode
Dimensions in inches (mm)
1.180 (30)
Panel cutout dimensionsmounts from backside
R4.5
1.180 (30)
.865 (22)
1.573 (40)2- .142 (3.6)
1.967 (50)1.573 (40)
2- .142 (3.6)
.885(22.5)
1.534 (39)1.389(35.3)
.098(2.5)
.991(25.2).590 (15)
.142 (3.6)
.059(1.5)
.047 (1.2)
1.070(27.2)
.232 (5.9)
.708 (18)
.024 (.6)
.031 (.8)
.779(19.8)
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Inse
rtio
n Lo
ss (d
B)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
90
60-BHP-060-X-11
60-BHP-030-X-11
60-BHP-020-X-11
60-BHP-010-X-11
Inse
rtio
n Lo
ss (d
B)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
90
60-BHP-060-X-4
60-BHP-030-X-4
60-BHP-020-X-4
60-BHP-010-X-4
Inse
rtio
n Lo
ss (d
B)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
90
60-BHP-060-3-11
60-BHP-030-3-11
60-BHP-010-3-11
60-BHP-020-3-11
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Inse
rtio
n Lo
ss (d
B)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
90
60-BHP-060-3-4
60-BHP-030-3-4
60-BHP-010-3-4
60-BHP-020-3-4
60-BHP-XXX-X-11
60-BHP-XXX-X-4 60-BHP-XXX-3-4
60-BHP-XXX-3-11
60-BHPPCBMountingType
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Cur
rent
(%)
Temperature Characteristics
60-BHP Series
Power Entry ModulesHigh Frequency AttenuationBolt-in for PCB Applications
PCB
Pow
er F
ilte
rs
57SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
58
PCB
Pow
er F
ilte
rs
PCB Power FiltersMiniature Printed Circuit Board
Features Miniature general purpose PCB mounted filter Requires minimal PCB real estate space Low cost Operating temperature: -25°C to +70°C Two forms of cases are available:
metal case and plastic case
Applications Personal computers and peripherals Digital equipment Measuring instruments and medical equipment TV & VCR monitors and display units Home appliances
Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 17.5g
11-MPC Series
Circuit 1
Circuit 2
Circuit 3
Circuit Diagram
Specifications
Model
11-MPC-001-2-B
11-MPC-001-5-A
11-MPC-001-5-B
11-MPC-002-5-B
11-MPC-002-5-D
11-MPC-003-5-E
11-MPC-006-5-B
11-MPC-006-5-C
11-MPC-016-5-B
Rated Voltage(@ 50/60Hz)
120/250VAC
RatedCurrent
1A
2A
3A
6A
16A
Leakage Current(Max.)
5uA
0.50mA
0.2mA
CircuitDiagram
1
2
3
2
4
Figure
B
A
B
D
E
B
C
B
Temperature Rise(Max.)
30°C
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
59
PCB
Pow
er F
ilte
rs
11-MPC Series
PCB Power FiltersMiniature Printed Circuit Board
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Common Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Normal Mode
11-MPC-001;-002
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
11-MPC-001-5-A
11-MPC-002-5-B
11-MPC-001-2-B
11-MPC-001-5-B
11-MPC-002-5-D
11-MPC-003;-006;-016
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
11-MPC-003-5-E
11-MPC-016-5-B
11-MPC-006-5-B
11-MPC-006-5-C
11-MPC-001;-002
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
11-MPC-001-5-A
11-MPC-001-2-B
11-MPC-001-5-B
11-MPC-002-5-B
11-MPC-002-5-D
11-MPC-003;-006;-016
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
11-MPC-003-5-E
11-MPC-006-5-B
11-MPC-006-5-C
11-MPC-016-5-B
2.0(51)
1.4 (36)
0.9 (25)
2.5 (64)
0.9(25)±.007
0.6 (15)±.03
Figure B
0.6(16)
0.6(15)
0.9 (25) 0.4(10)
0.9(25)
0.6(16)
Figure A
0.6(16)
0.6 (15)±.07
0.3 (8)
0.3 (8)1.1(28)
1.4 (36)
1.8 (45)
0.03 (1) (5X)
Figure D
1.4 (35.5)
.45(11.5)
1.9 (49)
.45(11.5)
1.4(35)
1.1 (27) .15(4)
Figure E
1.9 (30)
.79 (20)1.1 (29)
1.7 (44)
.30 (7.5)
.60(15)±.07
.30 (7.5)
.03 (1) (5X)
Figure C
Dimensions in inches (mm)
Features Low-cost plastic case Compact design requires minimal real estate space Suitable for products that must conform
to FCC regulations Wide variety of circuit and filtering options Good filtering characteristics for both normal mode
and common mode Epoxy molded for reliability Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 61)
Applications Personal computers and peripherals Digital equipment Industrial equipment Vending machines Home appliances Office equipment
Pow
er L
ine
Filt
ers 62-A*L
Series
62-A*CSeries
* R= w/ Bleeder Resistor F = w/o Bleeder Resistor
L
L
CX
CX
CY1
CY1
CY2
CY2
R
R
Circuit Diagrams
Power Line FiltersAppliance Filters
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max.
Dimensions in inches (mm)
.629(16.0)
Fast-on tab #110
.177 x .138 (4.5 x 3.5)
.263 (6.7)
.657(16.7)
.371(9.4)
1.527 (38.8).371(9.4)
1.573 (40.0)
.994 (24.0)
1.220(31.0)
.374 (9.5)
60 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Model*Rated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY CX (L1) Rise (Max.)
Specifications
62-AFL-010-3-110.35mA 2200pF
3300pF0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
62-AFC-010-3-111.0A
0.1uF
1.6A
3.0A 40°C
11.0mH
6.0mH
2.4mH
1.0mH
0.53mH
4.5A
6.0A
250VAC
62-AFL-010-5-1162-AFC-010-5-1162-AFL-016-3-1162-AFC-016-3-1162-AFL-016-5-1162-AFC-016-5-1162-AFL-030-3-1162-AFC-030-3-1162-AFL-030-5-1162-AFC-030-5-1162-AFL-045-3-1162-AFC-045-3-1162-AFL-045-5-1162-AFC-045-5-1162-AFL-060-3-1162-AFC-060-3-1162-AFL-060-5-1162-AFC-060-5-11
0.35mA
0.50mA
0.35mA
0.50mA
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
* Available with bleeder resistorReplace F with R for part number
Tested and found to beIAW VDE 0565 Part 3
62-AL/62-AC Series
Pow
er L
ine
Filt
ers
62-AL/62-AC Series
Power Line FiltersAppliance Filters
Common Mode
Normal Mode
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
62-AFL-xxx-5-11
62-AFL-010-5-11
62-AFL-030-5-1162-AFL-016-5-11
62-AFL-045-5-11
62-AFL-060-5-11
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
62-AFC-XXX-3-11
62-AFC-010-3-11
62-AFC-030-3-11
62-AFC-016-3-11
62-AFC-045-3-1162-AFC-060-3-11
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
62-AFC-XXX-3-11
62-AFC-010-3-11
62-AFC-030-3-11
62-AFC-016-3-11
62-AFC-045-3-11
62-AFC-060-3-11
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Cur
rent
(%)
Temperature Characteristics
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
62-AFL-xxx-3-11
62-AFL-010-3-11
62-AFL-030-3-11
62-AFL-016-3-11
62-AFL-045-3-11
62-AFL-060-3-11
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
62-AFC-xxx-5-11
62-AFC-010-5-11
62-AFC-030-5-1162-AFC-016-5-11
62-AFC-045-5-11
62-AFC-060-5-11
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
62-AFL-xxx-5-11
62-AFL-010-5-11
62-AFL-030-5-11
62-AFL-016-5-11
62-AFL-045-5-11
62-AFL-060-5-11
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
62-AFL-XXX-3-11
62-AFL-010-3-11
62-AFL-030-3-11
62-AFL-016-3-11
62-AFL-045-3-11
62-AFL-060-3-11In
sert
ion
Loss
(dB
)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
62-AFC-xxx-5-11
62-AFC-010-5-11
62-AFC-030-5-1162-AFC-016-5-11
62-AFC-045-5-11
62-AFC-060-5-11
61SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Normal Mode
Features Low-cost plastic case Compact design requires minimal real estate space Suitable for products that must conform
to FCC and FTZ regulations Wide variety of circuit and filtering options Good filtering characteristics for both normal mode
and common mode Epoxy molded for reliability Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 63)
Applications Personal computers and peripherals Digital equipment Industrial equipment Vending machines Office equipment
62-PQF*Series
62-PPF*Series
62-PRF*Series
* Bleeder Resistor is available only for62-P(Q/R/P)F-XXX-X-12
R
R
R
L1
L1
L1
L1
CX
CX
CX CY
CY
CY
CY
CY
CY
Circuit Diagrams
Power Line FiltersSingle Stage
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. (except 62-PRF-010-5-11) at rated current
62-PRF-010-5-11: 1.5V max. at rated currentWeight: 62-PPF & PQF Series: 2.11 ounces (60 grams)
62-PRF Series: 1.76 ounces (50 grams)
62-PPF/PQF/PRF Series
Pow
er L
ine
Filt
ers
62 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
ModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY CX (L1) Rise (Max.)
Specifications
62-PQF-020-5-11
0.50mA
62-PQF-020-5-122A
0.1uF
3A
6A
30°C
15mH
8mH
2.1mH
1A
3A
250VAC
62-PPF-020-5-1162-PPF-020-5-1262-PQF-030-5-1162-PQF-030-5-1262-PPF-030-5-1162-PPF-030-5-1262-PQF-060-5-1162-PQF-060-5-1262-PPF-060-5-1162-PPF-060-5-1262-PRF-010-5-1162-PRF-010-5-1262-PRF-020-5-1162-PRF-020-5-1262-PRF-030-5-1162-PRF-030-5-12
3300pF
2A
.22uF0.1uF.22uF0.1uF.22uF0.1uF.22uF0.1uF.22uF0.1uF.22uF0.1uF.22uF0.1uF.22uF0.1uF.22uF
486uH
97uH
181uH
Tested and found to beIAW VDE 0565 Part 3
Power Line FiltersSingle Stage
Common Mode
Normal Mode
Dimensions in inches (mm)
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
62-PRF-010-5-11
62-PRF-010-5-12
62-PRF-030-5-11
62-PRF-030-5-12
62-PRF Series62-P(P/Q/R)F Series
62-PPF Series
62-PQF Series
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
62-PPF-020-5-12
62-PPF-020-5-11
62-PPF-060-5-11
62-PPF-060-5-12
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
62-PQF-020-5-12
62-PQF-020-5-11
62-PQF-060-5-11
62-PQF-060-5-12
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
62-P(Q/P)-060-5-11
62-P(Q/P)-020-5-11
62-P(Q/P)-030-5-11
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
.786 (20)
1.573 (40)
Fast-on tab #110
.177 x .138 (4.5 x 3.5)
.590 (15)
.904 (23)
.354 (9)
1.947 (49.5).354 (9)
2.006 (51)
1.265 (32)
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Cur
rent
(%)
Temperature Characteristics
Also available with .250 Fast-ons
62-PPF/PQF/PRF Series
Pow
er L
ine
Filt
ers
63SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Features Compact design requires minimal real estate space Suitable for products that must conform
to FCC and FTZ regulations Excellent attenuation for high voltage impulse Metal case provides effective shielding Excellent filtering characteristics for both normal mode
and common mode Structure provides effective shielding for noise
generated externally and internally Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 65)
Applications Digital equipment Personal computers and peripherals Measuring instruments Medical equipment Factory automation equipment
1
2
3
E
4
RCX
L1
CX
CY
CY
Circuit Diagram
Power Line FiltersSingle Stage Wire Leads
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 62-PML-015 Series: 3.06 ounces (87 grams)
62-PML-030 Series: 3.17 ounces (90 grams)62-PML-050 Series: 3.28 ounces (93 grams)
Discharge time: 0.4 sec. max.
62-PML Series
Pow
er L
ine
Filt
ers
64 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Specifications
62-PML-015-3-11
62-PML-015-5-11
62-PML-030-3-11
62-PML-030-5-11
62-PML-050-3-11
62-PML-050-5-11
62-PML-100-5-11
ModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY CX (L1) Rise (Max.)
250VAC
1.5A
3A
5A
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.50mA
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
3300pF
0.1uF
10.0mH
4.3mH
2.4mH
2.2mH
30°C
10A
Tested and found to beIAW VDE 0565 Part 3
Power Line FiltersSingle Stage Wire Leads
Common Mode Normal Mode
62-PML 62-PML
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
62-PML-030-5-21
62-PML-050-5-21
62-PML-015-5-21
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Inse
rtio
n Lo
ss (d
B)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
90
62-PML-015-5-11
62-PML-030-5-11
62-PML-050-5-11
Dimensions in inches (mm)
BK
BK
PVCInsulated wireAWG # 20 UL1015
WH
G/Y
WH
1.573 (40)
2 — .138 x .181 (3.5 x 4.6)
1.219 (31)
.629 (16)
.944 (24)
.786 (20) 1.966
(50)
5.112* (130)
.395 (10).395 (10)
1.856 (47.2)5.112* (130)
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Cur
rent
(%)
Temperature Characteristics
62-PML Series
Pow
er L
ine
Filt
ers
65SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
* Custom lengths available upon request.
66 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Circuit 1
Circuit 2
Circuit Diagram
Features Compact design requires minimal real estate
space Suitable for products that must conform
to FCC and FTZ regulations Excellent attenuation for high voltage impulse Metal case provides effective shielding Excellent filtering characteristics for both normal
mode and common mode Structure provides effective shielding for noise
generated externally and internally Operating temperature: -25°C to +70°C Low leakage current
Applications Digital equipment Personal computers and peripherals Measuring instruments Medical equipment Factory automation equipment
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentDischarge time: 0.4 sec. max.
12-PML & 12-PMF Series
Pow
er L
ine
Filt
ers
Power Line FiltersSingle Stage Wire Leadsfor Medical Purpose Applications
Specifications
Model
12-PML-001-2-A
12-PML-002-2-A
12-PML-006-2-A
12-PML-010-2-A
12-PMF-001-2-B
12-PMF-002-2-B
12-PMF-006-2-B
12-PML-001-2-C
Rated Voltage(@ 50/60Hz)
120/250VAC
RatedCurrent
1A
2A
6A
10A
1A
2A
6A
1A
Leakage Current(Max.)
5uA
CircuitDiagram
1
2
1
Temperature Rise(Max.)
30°C
Figure
A
B
C
67SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line FiltersSingle Stage Wire Leadsfor Medical Purpose Applications
12-PML & 12-PMF Series
Pow
er L
ine
Filt
ers
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Common Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Normal Mode
12-PML-001;-002;-006;-010
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
12-PML-001-2-A
12-PML-002-2-A
12-PML-006-2-A
12-PML-010-2-A
12-PMF-001;-002;-006;-010
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
12-PMF-001-2-B 12-PMF-002-2-B
12-PMF-006-2-B
11-PML-001-2-C
12-PML-001;-002;-006;-010
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
12-PML-001-2-A
12-PML-002-2-A 12-PML-006-2-A
12-PML-010-2-A
12-PMF-001;-002;-006;-010
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
11-PML-001-2-C
12-PMF-001-2-B 12-PMF-002-2-B
12-PMF-006-2-B
1.2(30)
.79 (20)
.14 (3.8) (2X)
1.7 (44)
2.2 (56)2.4 (61)
Figure B
1.2(30)
1.7 (44)
.13 (3.5) X .17 (4.5) SLOT (2 PLACES)
1.5(39)
1.9(49)
.31 (8)
.78 (20)
Figure A
.94(24)
1.25 (32)
.13 (3.5) X .17 (4.5) SLOT (2 PLACES)
.78 (20)1.6 (42)1.9 (48)
Figure C
Dimensions in inches (mm)
1
2
3
E
4
RCX CX
L1
CY
CY
Circuit Diagram
Power Line FiltersSingle Stage
Features Space saving, compact designs Suitable for products that must conform
to FCC and FTZ regulations Excellent filtering characteristics for both normal mode
and common mode Structure provides effective shielding for noise
generated externally and internally Metal case provides effective shielding Rugged construction Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 69)
Applications Digital equipment Office automation equipment, such as copy
and fax machines Computers and peripherals Instrumentation and controls
Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentDischarge time: 0.4 sec. max.Weight: 5.3 ounces (150 grams)
62-LMF & LMB Series
Pow
er L
ine
Filt
ers
68 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Specifications
62-LMB-030-5-11
62-LMF-030-5-11
62-LMB-050-5-11
62-LMF-050-5-11
62-LMB-080-5-11
62-LMF-080-5-11
62-LMB-100-5-11
62-LMF-100-5-11
Model*Rated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY CX (L1) Rise (Max.)
250VAC
3A
5A
8A
0.50mA 3300pF
14mH
7.0mH
4.2mH
2.2mH
45°C
0.1uF
0.1uF & .22uF
.22uF
.33uF10A
*62-LMF - designates Fast-on terminals62-LMB - designates Bolt-in terminals62-LML - wire lead in/outputs also available
Tested and found to beIAW VDE 0565 Part 3
Power Line FiltersSingle Stage
Common Mode Normal Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Inse
rtio
n Lo
ss (d
B)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
90
62-LM-030-5-11 62-LM-050-5-11
62-LM-080-5-11
62-LM-100-5-11
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Inse
rtio
n Lo
ss (d
B)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
9062-LM-030-5-11
62-LM-050-5-11
62-LM-080-5-11
62-LM-100-5-11
62-LMF & LMB 62-LMF & LMB
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Cur
rent
(%)
Temperature Characteristics
2 - ø .188(4.8)
5-M4
2.79(70.9)
2.39(60.7± 0.5)
1.22(31.0)
1.10(28.0)
.708(18.0)
.255(6.5)
.66(16.8)
1.97(50.0)
.61(15.5)
1.97(50.0)
.66(16.8)
62-LMF
.61(15.5)
2.79(70.9)
2.39(60.7± 0.5)
1.22(31.0)
1.10(28.0)
.708(18.0)
.255(6.5)
2 - ø4.8
.61(15.5)
1.97(50.0)
.61(15.5)
1.97(50.0)
Fast-on Tabs #250.031 (0.8) t
Dimensions in inches (mm)
62-LMB
Pow
er L
ine
Filt
ers
69SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
62-LMF & LMB Series
Features Space-saving, compact designs Suitable for products that must conform
to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Excellent filtering characteristics for both normal mode
and common mode Epoxy molded for internal component reliability Structure provides effective shielding for noise
generated externally and internally Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 71)
Applications Digital equipment Computers and peripherals Measuring instruments Medical equipment Equipment requiring very high impulse attenuation Factory automation equipment Industrial equipment such as UPS, inverters
and converters Telecommunications equipment Office automation equipment, such as copy
and fax machines
1
2
3
E
4
RCX CX
L1
CY
CY
Circuit Diagram
Power Line FiltersSingle Stage
* PMF - designates Fast-on terminalsPMB - designates Bolt-in terminals
** The temperature rise of 20 amp units can be decreased to 30°Cby mounting on 200 X 200 x 1.0(mm) steel chassis
62-PMF & PMB Series
Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max.Discharge time: 0.4 sec. max.Weight: 8.82 ounces ( 250 grams)
Pow
er L
ine
Filt
ers
70 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Specifications
62-PMB-050-5-11
62-PMF-050-5-11
62-PMB-080-5-11
62-PMF-080-5-11
62-PMB-100-5-12
62-PMF-100-5-12
62-PMB-150-5-13
62-PMF-150-5-13
62-PMB-200-5-13
62-PMF-200-5-13
Model*Rated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY CX (L1) Rise (Max.)
250VAC
5A
8A
10A 0.50mA
14mH
7.0mH
4.2mH
2.2mH
30°C
0.1uF
.1uF & .22uF
.22uF
.33uF
1.8mH
3300pF
15A
20A 45°C**
35°C
Tested and found to beIAW VDE 0565 Part 3
Power Line FiltersSingle Stage
Common Mode Normal Mode
3.291 (83.7)
2.937 (74.7) Fast-on tab#250
.610(15.5)
2.497 (63.5) .610(15.5)
2 — .197 (5)
B
C
1.258 (32)
.315 (8)
1.998(50.8)
A
3.291 (83.7)
2.937 (74.7) 5 — .157 (M4)
2 — .197 (5)
.649(16.5)
.649(16.5) 2.497 (63.5) A
B
C
.315 (8)
1.258 (32)
1.998(50.8)
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Inse
rtio
n Lo
ss (d
B)
80
70
60
50
40
30
20
10
0
62-PMB-200-5-13
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
90
62-PMB-100-5-12
62-PMB-080-5-11
62-PMB-050-5-11
62-PMB-150-5-13
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Inse
rtio
n Lo
ss (d
B)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
90
62-PMF-150-5-13
62-PMF-050-5-11
62-PMF-080-5-11
62-PMF-100-5-12
62-PMB-200-5-13
MODEL A B C
62-PMF/PMB-100-200
62-PMF/PMB-050-080
1.490 .944 .433(38) (24) (11)
1.258 .786 0(32) (20) (0)
62-PMB-050-6
62-PMF
62-PMB
62-PMB-050-6
50ΩLevelMeter
R1 R2S1 S2Filter
Oscillator50Ω 50
Ω
50Ω
T1 T2
50Ω
50Ω
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Cur
rent
(%)
Temperature Characteristics
50ΩLevelMeter
R1 R2S1 S2Filter
Oscillator50Ω
T1 T2
50Ω
50Ω
Pow
er L
ine
Filt
ers
71SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Dimensions in inches (mm)
62-PMF & PMB Series
72 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Circuit 1
Circuit 3
Circuit 5
Circuit 2
Circuit 4
Circuit 6
Circuit Diagram
Power Line FiltersSingle Stage
Features Space-saving, compact designs Suitable for products that must conform
to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Excellent filtering characteristics for both normal mode
and common mode Epoxy molded for internal component reliability Structure provides effective shielding for noise
generated externally and internally Operating temperature: -40°C to +85°C
Applications Digital equipment Computers and peripherals Measuring instruments Medical equipment Equipment requiring very high impulse attenuation Factory automation equipment Industrial equipment such as UPS, inverters
and converters Telecommunications equipment Office automation equipment, such as copy
and fax machines
12-PMF Series
Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max.Discharge time: 0.4 sec. max.
Pow
er L
ine
Filt
ers
Model
12-PMF-001-5-A
12-PMF-002-5-B
12-PMF-003-5-A
12-PMF-003-5-B
12-PMF-006-5-A
12-PMF-006-5-C
12-PMF-006-5-D
12-PMF-010-5-A
12-PMF-010-5-C
12-PMF-015-5-C
12-PMF-015-5-E
12-PMF-020-5-C
12-PMF-020-5-D
12-PMF-020-5-E
Rated Voltage(@ 50/60Hz)
120/250VAC
RatedCurrent
1A
2A
3A
6A
10A
15A
20A
Leakage Current(Max.)
0.5mA
CircuitDiagram
1
2
4
2
4
1
6
2
3
5
Temperature Rise(Max.)
30°C
Figure
A
B
A
B
A
C
D
A
C
E
C
D
E
Specifications
2.4(62)
.86 (22)
1.8(46)
1.25 (32)
2.4 (62)
2.1(54)
.14 (3.8)
73SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line FiltersSingle Stage
Pow
er L
ine
Filt
ers
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Common Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Normal Mode
12-PMF-001;-002;-003;-006
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
12-PMF-001-5-A
12-PMF-003-5-B
12-PMF-002-5-B
12-PMF-003-5-A
12-PMF-006-5-A
12-PMF-006-5-C
12-PMF-006-5-D
12-PMF-001;-002;-003;-006
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
12-PMF-001-5-A
12-PMF-003-5-B
12-PMF-002-5-B
12-PMF-003-5-A
12-PMF-006-5-A
12-PMF-006-5-C
12-PMF-006-5-D
12-PMF-001;-002;-003;-006
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
12-PMF-001-5-A
12-PMF-002-5-B
12-PMF-003-5-A
12-PMF-003-5-B
12-PMF-006-5-A
12-PMF-006-5-C
12-PMF-006-5-D
12-PMF-010;-015;-020
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
12-PMF-010-5-A
12-PMF-010-5-C
12-PMF-015-5-C
12-PMF-015-5-E
12-PMF-020-5-C
12-PMF-020-5-E12-PMF-020-5-D
Figure A
1.2(30)
1.7 (44)
.34 (8.8)
2.2 (56)
3.2 (81)
.78 (20)
2
Figure B
2.0(52)
2.0 (52)
.17 (8.8)
2.4 (63)
3.2 (82)
1.4 (37)
2
Figure C
1.9(50)
1.7 (44)
2.9 (74)
.41 (10.5)
1.1 (28)
2.3(60)
2.8(10.5)
2 - .18 (4.8)
Figure D
2.9(74)
3.1 (80)
3.3(85)
2.5(64)
2.0 (51)
1.4 (36)
1.7 (4.5) (2X)
Figure E
12-PMF Series
Dimensions in inches (mm)
Circuit Diagram
Power Line FiltersSingle Stage - Higher Current
Features Space-saving, compact designs Suitable for products that must conform
to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective shielding Excellent filtering characteristics for both normal mode
and common mode Epoxy molded for internal component reliability Structure provides effective shielding for noise
generated externally and internally Safety agency approvals pending Designed to be in accordance with VDE 0565 Part 3 Operating temperature: -25°C to +85°C
(including temperature rise)
Applications Digital equipment Computers and peripherals Measuring instruments Medical equipment Equipment requiring very high impulse attenuation Factory automation equipment Industrial equipment such as UPS, inverters
and converters Telecommunications equipment Office automation equipment, such as copy
and fax machines
62-PMB Series
Note: Test voltage: 1500VAC one minute, line to earthInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max.Discharge time: 0.4 sec. max.Weight: 8.82 ounces (250 grams)
1
2
CX R E
4
3
CX
CY
CY
L1
L1
Pow
er L
ine
Filt
ers
74 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Specifications
62-PMB-300-5-14
62-PMB-400-5-14
ModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY CX (L1) Rise (Max.)
250VAC
30A
40A
0.50mA
1.6mH
0.8mH
45°C3300pF .47uF
3.03 (77±0.5)
3.70 (94)
3.85 (98)
5.591 (142.00)
3.15 (80)
3.74 (95±.08)
4.13 (105)
2.049 (52.0)
1.022 (26.0)
0.511 (13.0)
62-PMB-300-5-14 and 62-PMB-400-5-14
Inse
rtio
n Lo
ss (d
B)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
90
62-PMB-400-5-14
62-PMB-300-5-14
Common ModeNormal Mode
Inse
rtio
n Lo
ss (d
B)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
90
62-PMB-400-5-14
62-PMB-300-5-14
1
2
3
4
OSCILLATOR50 ohm 50 ohm 50 ohm
FILTER
50 ohmLEVELMETER
1
2
3
4
50 ohm
50 ohmLEVELMETEROSCILLATOR
50 ohm
FILTER
Power Line FiltersSingle Stage - Higher Current
Dimensions in inches (mm)
Pow
er L
ine
Filt
ers
75SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
62-PMB Series
76 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Circuit Diagram
Power Line FiltersSingle Stage - Higher Current
Features Space-saving, compact designs Suitable for products that must conform
to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective shielding Excellent filtering characteristics for both normal mode
and common mode Epoxy molded for internal component reliability Structure provides effective shielding for noise
generated externally and internally Designed to be in accordance with VDE 0565 Part 3 Operating temperature: -40°C to +85°C
Applications Digital equipment Computers and peripherals Measuring instruments Medical equipment Equipment requiring very high impulse attenuation Factory automation equipment Industrial equipment such as UPS, inverters
and converters Telecommunications equipment Office automation equipment, such as copy
and fax machines
12-PMB Series
Note: Test voltage: 1500VAC one minute, line to earthInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max.Discharge time: 0.4 sec. max.Weight: 8.82 ounces (250 grams)
1
2
CX R E
4
3
CX
CY
CY
L1
L1
Pow
er L
ine
Filt
ers
Specifications
Model
12-PMB-025-5-A
12-PMB-030-5-A
12-PMB-035-5-B
12-PMB-050-5-B
12-PMB-100-8-C
12-PMB-120-8-C
Rated Voltage(@ 50/60Hz)
120/250VAC
RatedCurrent
25A
30A
35A
50A
100A
120A
Leakage Current(Max.)
0.5mA
1.0mA
CircuitDiagram
1
Figure
A
B
C
Temperature Rise(Max.)
30°C
77SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line FiltersSingle Stage - Higher Current
Pow
er L
ine
Filt
ers
12-PMB Series
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Common Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Normal Mode
12-PMB-025;-030;-035
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
12-PMB-025-5-A
12-PMB-030-5-A
12-PMB-035-5-B
12-PMB-050;-100;-120
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
12-PMB-050-5-B
12-PMB-100-8-C
12-PMB-120-8-C
12-PMB-025;-030;-035
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
12-PMB-025-5-A
12-PMB-030-5-A
12-PMB-035-5-B
12-PMB-050;-100;-120
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
12-PMB-050-5-B
12-PMB-100-8-C
12-PMB-120-8-C
2.0(52)
2.0(24) ±.03
0.2 (6) ±.030.8 (22)
±.031.4 (37) MAX
1M4 STUD(4X)
.17 (4.5) ±.007(2X)
3.9 (101) MAX
2.5 (64) MAX
2.9 (75) ±.01
3.3(84)
1.5 (38.5)
5.3 (135)
3.9 (98.5)2.0 (51)
0.2 (6.3)0.5 (4.5)
3.7(95)
4.1(105)
M4 THREAD (10X)
5.1(130)
1.9 (50) 3.1 (80)
4.7 (120)7.0 (180)
4.3(110)
4.5(115)
0.16 (4.2) X 0.25 (6.4) (2X)M8 THREAD (4X)
Figure A Figure B Figure C
Dimensions in inches (mm)
78 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Circuit Diagram
Power Line FiltersDC - Higher Current
Features Space-saving, compact designs Suitable for products that must conform to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective shielding Excellent filtering characteristics for both normal mode
and common mode Epoxy molded for internal component reliability Structure provides effective shielding for noise
generated externally and internally Designed to be in accordance with VDE 0565 Part 3 Operating temperature: -40°C to +85°C
Applications Digital equipment Computers and peripherals Measuring instruments Equipment requiring very high impulse attenuation Factory automation equipment Industrial equipment such as UPS, inverters and converters Telecommunications equipment
12-PMF & 12 PMB DC Series
Note: Test voltage: 1500VAC one minute, line to earthInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max.
Circuit 1
Circuit 2
Circuit 3
Pow
er L
ine
Filt
ers
SpecificationsRated Voltage(@ 50/60Hz)
48/250VDC
CircuitDiagram
1
2
3
2
Figure
A
B
C
D
E
F
G
Temperature Rise(Max.)
30°C
Discharge time: 0.4 sec. max.Weight: 8.82 ounces (250 grams)
Model
12-PMF-006-DC-C
12-PMF-010-DC-C
12-PMF-015-DC-C
12-PMF-020-DC-C
12-PMF-025-DC-D
12-PMB-025-DC-F
12-PMB-030-DC-F
12-PMB-035-DC-F
12-PMB-040-DC-F
12-PMB-040-DC-B
12-PMB-050-DC-B
12-PMB-060-DC-B
12-PMB-080-DC-G
12-PMB-080-DC-C
12-PMB-100-DC-C
12-PMB-120-DC-C
12-PMB-140-DC-C
12-PMB-180-DC-E
12-PMB-200-DC-E
12-PMB-260-DC-E
RatedCurrent
6A
10A
15A
20A
25A
30A
35A
40A
50A
60A
80A
100A
120A
140A
180A
200A
260A
79SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line FiltersDC - Higher Current
Pow
er L
ine
Filt
ers
12-PMF & 12-PMB DC Series
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Common Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Normal Mode
12-PMF-006;-010;-015;-020;-025
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
12-PMF-006-DC-C
12-PMF-010-DC-C
12-PMF-015-DC-C
12-PMF-020-DC-C
12-PMF-025-DC-D
12-PMB-025; thru -260
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
12-PMB-025-DC-F12-PMB-030-DC-F12-PMB-035-DC-F12-PMB-040-DC-F
12-PMB-040-DC-B12-PMB-050-DC-B12-PMB-060-DC-B
12-PMB-080-DC-G12-PMB-080-DC-C
12-PMB-100-DC-C12-PMB-120-DC-C12-PMB-140-DC-C
12-PMB-180-DC-E12-PMB-200-DC-E12-PMB-260-DC-E
12-PMF-006;-010;-015;-020;-025
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
12-PMF-006-DC-C
12-PMF-010-DC-C
12-PMF-015-DC-C
12-PMF-020-DC-C
12-PMF-025-DC-D
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
12-PMB-025; thru -260
12-PMB-025-DC-F12-PMB-030-DC-F12-PMB-035-DC-F12-PMB-040-DC-F
12-PMB-040-DC-B12-PMB-050-DC-B12-PMB-060-DC-B
12-PMB-080-DC-G12-PMB-080-DC-C
12-PMB-100-DC-C12-PMB-120-DC-C12-PMB-140-DC-C
12-PMB-180-DC-E12-PMB-200-DC-E12-PMB-260-DC-E
1.9 (50)±.003
Figure C Figure D
Figure E Figure F Figure G
Figure A
Figure B
Dimensions in inches (mm)
80 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line FiltersDual Stage
Features Suitable for products that must conform
to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Two stages for excellent filtering characteristics Epoxy molded for reliability Structure provides effective shielding for noise
generated both externally and internally Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 81)
Applications Digital equipment Personal computers and peripherals Measuring instruments and medical equipment Telecommunications equipment Equipment requiring very high noise attenuation
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCLeakage current: 0.7 mA max.Voltage drop: 1V max.Discharge time: 0.4 sec. max.Weight: 6.0 ounces (170 grams)
62-MMF Series
1 3
E
42
CX
L1CX
RCX
CY
CY CY
CY
L1
62-MMF-XXX-7-11
Circuit Diagram
Pow
er L
ine
Filt
ers
SpecificationsModel
Rated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY1 CY2 CX (L1) (2X) Rise (Max.)
62-MMF-030-7-11 250VAC 3A .7mA 3300pF 1000pF 0.1uF 3.7mH 30°C
62-MMF-050-7-11 250VAC 5A .7mA 3300pF 1000pF 0.1uF 2.9mH 30°C
81SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Cur
rent
(%)
Temperature Characteristics
62-MMF Series
Common Mode Normal Mode
Dimensions in inches (mm)
Inse
rtio
n Lo
ss (d
B)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
90
62-MMF-030-7-11
62-MMF-050-7-11
62-MMF
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Inse
rtio
n Lo
ss (d
B)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
90
62-MMF-050-7-11
62-MMF-030-7-11
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
3.291 (83.7)
2.937 (74.7) Fast-on tab#250
2 – .197 (5)
.610(15.5)2.497 (63.5)
.610(15.5)
.786 (20)
.315 (8)
1.258 (32).315
(8) 1.998(50.8)
1.258 (32)
62-MMF
Pow
er L
ine
Filt
ers
Power Line FiltersDual Stage
82 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line FiltersDual Stage
Features Suitable for products that must conform
to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Two stages for excellent filtering characteristics Structure provides effective shielding for noise
generated both externally and internally Operating temperature: -40°C to +85°C High performance Low leakage current
Applications Digital equipment Switching power supplies Personal computers and peripherals Measuring instruments and medical equipment Telecommunications equipment Equipment requiring very high noise attenuation
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCLeakage current: 0.7 mA max.Voltage drop: 1V max.Discharge time: 0.4 sec. max.
12-MMF & 12-MMB Series
Circuit 1
Circuit 2
Circuit 3
Circuit Diagram
Pow
er L
ine
Filt
ers
SpecificationsRated Voltage(@ 50/60Hz)
120/250VAC
LeakageCurrent (Max.)
0.5mA
Figure
A
B
C
B
D
B
D
E
D
F
G
Temperature Rise(Max.)
30°C
RatedCurrent
2A
3A
6A
8A
10A
12A
15A
20A
30A
50A
Model
12-MMF-002-5-F
12-MMF-003-5-F
12-MMF-003-5-A
12-MMF-006-5-F
12-MMF-006-5-G
12-MMF-008-5-B
12-MMF-010-5-F
12-MMF-010-5-G
12-MMF-010-5-B
12-MMF-012-5-B
12-MMB-015-5-E
12-MMB-020-5-F
12-MMB-030-5-D
12-MMB-050-5-C
CircuitDiagram
1
3
2
83SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
12-MMF & 12-MMB Series
Power Line FiltersDual Stage
Pow
er L
ine
Filt
ers
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Common Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Normal Mode
12-MMF-002;-003;-006;-008
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.01 0.05 0.15 1 2 5 10 20 50
12-MMF-002-5-F
0.45
12-MMF-003-5-F
12-MMF-003-5-A
12-MMF-006-5-F12-MMF-006-5-G
12-MMF-008-5-B
12-MMF-010;-012;-015;-020;-030;-050
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.01 0.05 0.15 1 2 5 10 20 500.45
12-MMB-015-5-E
12-MMB-020-5-F
12-MMB-030-5-D
12-MMB-050-5-C
12-MMF-010-5-F12-MMF-010-5-G12-MMF-010-5-B12-MMF-012-5-B
12-MMF-002;-003;-006;-008
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.01 0.05 0.15 1 2 5 10 20 500.45
12-MMF-003-5-A
12-MMF-006-5-G
12-MMF-003-5-F
12-MMF-002-5-F12-MMF-006-5-F
12-MMF-008-5-B
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
0
12-MMF-010;-012;015;-020;-030;-050
0.01 0.05 0.15 1 2 5 10 20 500.45
12-MMB-015-5-E12-MMB-020-5-F
12-MMB-030-5-D
12-MMB-050-5-C
12-MMF-010-5-F12-MMF-010-5-G12-MMF-010-5-B12-MMF-012-5-B
2.00(51)
2.00 ± .02 (75 ± .5)3.35 (85) MAX
Figure A Figure B
.87 (22)2.44 (62)
2.44(62)
1.81(46)
1.26 (32)
2.12(54)
Ø .15 (3.8) (2X)Figure C
2.40 ± .007(60 ± .2)
1.50 (38) 7.24 (184)7.95 (202)
M4 STUD (7X) .21 (5.4) X .37 (9.4) HOLE (4X)
6.30 (160)
3.38(86)
1.65(42)
.71 (18)
2.30 (58)
Figure E
2.01 (51)
3.30(84)
3.74(95)
4.13(105)
3.88 (98.5)5.31 (135)
.117 (4.5) X .25 (6.3) SLOT (4X)M4 THREAD (5X)
1.51 (38.5)
Figure F
3.15 (80)
3.93(100)
M6 THREAD (4X)
4.52(115)
5.12(130)
4.72 (120)7.09 (180)
M4 THREAD
1.97 (50)
Figure G
Dimensions in inches (mm)
2.42 (87)4.01 (102)
2.90 (73)
2.24(57)
1.77 (45)
Ø .25 (6.4) (2X)
Figure D
Temperature Rise(Max.)
30°C
Figure
A
B
C
B
D
E
F
RatedCurrent
3A
6A
10A
12A
15A
20A
30A
40A
50A
Model
12-MMF-003-11-F
12-MMF-006-11-F
12-MMF-010-11-F
12-MMB-012-11-A
12-MMB-015-11-G
12-MMB-020-11-D
12-MMB-030-11-D
12-MMB-040-11-B
12-MMB-040-11-E
12-MMB-050-11-H
84 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line FiltersDual Stage
Features Suitable for products that must conform
to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Two stages for excellent filtering characteristics Structure provides effective shielding for noise
generated both externally and internally Operating temperature: -40°C to +85°C High performance
Applications Digital equipment Personal computers and peripherals Measuring instruments and medical equipment Telecommunications equipment Equipment requiring very high noise attenuation
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCLeakage current: 0.7 mA max.Voltage drop: 1V max.Discharge time: 0.4 sec. max.Weight: 6.0 ounces (170 grams)
12-MMF & 12-MMB Series
Circuit 1
Circuit 2
Circuit Diagram
Pow
er L
ine
Filt
ers
SpecificationsRated Voltage(@ 50/60Hz)
120/250VAC
LeakageCurrent (Max.)
1.5mA
CircuitDiagram
1
2
1
2
1
2.28(58)
8.66 (220)9.57 (243)10.27 (261)
5.90(150)
3.54(90)
1.77 (45)3.54(90)
M6 THREAD (5X) .25 (6.4) x .37(9.4) SLOT (4X)
Figure D
2.91 (74)3.66 (93)4.01 (102)
2.24(57)
.95(24.1)
.177 (4.5) X .25 (6.5) SLOT (2X)
.35 (9)
.90 (23)1.77(45)
Figure E
1.97(50) 3.14 (80)
4.72 (120)
3.93(100)
.165 (4.2) X .25 (6.4) (4X)
M8 THREAD (4X)
7.08 (180)
4.53(115)
5.12(130)
Figure F
85SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
12-MMF & 12-MMB Series
Power Line FiltersDual Stage
Dimensions in inches (mm)
Pow
er L
ine
Filt
ers
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Common Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Normal Mode
12-MMF-003;-006;-010;-012;-015
Inse
rtio
n Lo
ss (d
B)
120
Frequency (MHz)
105
90
75
60
45
30
15
00.1 0.2 0.5 1 2 5 10 20 50
12-MMF-003-11-F
12-MMF-006-11-F
12-MMF-010-11-F
12-MMF-012-11-A
12-MMF-015-11-G
12-MMF-020;-030;-040;-050
Inse
rtio
n Lo
ss (d
B)
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
120
105
90
75
60
45
30
15
0
12-MMF-020-11-D
12-MMF-030-11-D
12-MMF-040-11-B
12-MMF-040-11-E
12-MMF-050-11-H
12-MMF-003;-006;-010;-012;-015
Inse
rtio
n Lo
ss (d
B)
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
120
105
90
75
60
45
30
15
0
12-MMF-003-11-F
12-MMF-006-11-F
12-MMF-010-11-F
12-MMF-012-11-A
12-MMF-015-11-G
Inse
rtio
n Lo
ss (d
B)
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
12-MMF-020;-030;-040;-050120
105
90
75
60
45
30
15
012-MMF-020-11-D
12-MMF-030-11-D
12-MMF-040-11-B
12-MMF-040-11-E
12-MMF-050-11-H
Figure A
1.53 MAX (39)
3.33MAX(84.5)
1.73± .04
(44 ± 1)
.75 ± .04 (19 ± 1)
6.20 MAX (157)3.90 MAX (99)
2.01 ± .02(51 ± 0.5)
3.74± .02
(95 ± 0.5)
4.13MAX(105)
Figure B
2.24(57)
2.90 (73)1.80 (45) 3.42 (87)
4.30 (109)
M4 THREAD (4X)Ø .18 ± .007 (2X)(4.5 ± 0.2)
Figure C
Figure
A
B
C
D
LeakageCurrent (Max.)
0.5mA
5uA
0.5mA
RatedCurrent
1A
3A
6A
10A
15A
20A
30A
Model
12-MMF-001-5-F
12-MMF-003-5-G
12-MMF-003-2-G
12-MMF-006-5-G
12-MMB-010-5-D
12-MMB-015-5-E
12-MMB-020-5-E
12-MMB-030-5-E
86 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line FiltersDual Stage
Features Suitable for products that must conform
to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Two stages for excellent filtering characteristics Epoxy molded for reliability Structure provides effective shielding for noise
generated both externally and internally Operating temperature: -25°C to +85°C
Applications Digital equipment Personal computers and peripherals Measuring instruments and medical equipment Telecommunications equipment Equipment requiring very high noise attenuation
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCLeakage current: 0.7 mA max.Voltage drop: 1V max.Discharge time: 0.4 sec. max.Weight: 6.0 ounces (170 grams)
12-MMF & 12-MMB Series
Circuit 1
Circuit 2
Circuit 3
Circuit Diagram
Pow
er L
ine
Filt
ers
SpecificationsRated Voltage(@ 50/60Hz)
120/250VAC
Temperature Rise(Max.)
30°C
CircuitDiagram
3
1
2
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Common Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Normal Mode
12-MMF-001;-003;-006
Inse
rtio
n Lo
ss (d
B)
120
Frequency (MHz)
105
90
75
60
45
30
15
00.1 0.2 0.5 1 2 5 10 20 50
12-MMF-001-5-F
12-MMF-003-5-G
12-MMF-003-2-G
12-MMF-006-5-G
12-MMB-010;-015;-020;-030
Inse
rtio
n Lo
ss (d
B)
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
120
105
90
75
60
45
30
15
0
12-MMB-010-5-D 12-MMB-015-5-E
12-MMB-020-5-E
12-MMB-030-5-E
12-MMF-001;-003;-006
Inse
rtio
n Lo
ss (d
B)
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
120
105
90
75
60
45
30
15
0
12-MMF-001-5-F
12-MMF-003-5-G
12-MMF-003-2-G
12-MMF-006-5-G
Inse
rtio
n Lo
ss (d
B)
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
12-MMB-010;-015;-020;-030120
105
90
75
60
45
30
15
0
12-MMB-010-5-D12-MMB-015-5-E12-MMB-020-5-E
12-MMB-030-5-E
87SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
12-MMF & 12-MMB Series
Power Line FiltersDual Stage
Dimensions in inches (mm)
Pow
er L
ine
Filt
ers
Figure B
2.95 (75)3.70 (94)
2.52 (64)
2.01(51)
1.06 (27)
Figure A
1.52 (39)MAX
1.73 ± .03(44 ± 1)
4.13 MAX.(64)
2.01 ± .02(51 ± .05)
3.15 (99) MAX5.31 (135) MAX
0.75 ± .03 (19 ± 1)
3.33(84.5)MAX
3.74 ± .02(95 ± 0.5)
M4 THREAD (5X)Figure C
2.36 ± .007(60 ± .2)
7.09 (180)7.24 (184)7.95 (202)
3.38(86)
1.50 (38).71 (18)
M4 STUD (7X)
1.65(42)
.25 (6.4) .37 (9.4) HOLE (4X)
2.28 (58)
Figure D
Power Line FiltersThree PhaseLow Current/High Performance
Features Excellent attenuation for high voltage impulse Effective for both balanced and unbalanced
three-phase loads Metal case provides effective EMI shielding Epoxy molded for internal component reliability Compact and economical Excellent filtering characteristics for both normal
and common mode Various current ratings available: 3, 5, 8 and 16 Amps Safety agency approvals pending Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 89)
Applications Digital equipment Industrial equipment (UPS, inverters
and converters) Automation equipment Computerized washing machines
Circuit Diagram
CX
CYCY
CX CX CX CX CX
L
L
L
L
CX
CX
CX
CY
CY
CY
L
L
L
L
CY
CX CX
CX
CY
CY
CY
L
L
L
L
L
L
62-PMB-050-6-12 (5 Amp Delta)
63-PMF-030-8-14 and 63-PMF-080-8-14 (3 and 8 Amp Wye)
63-PMF-160-9-21 (16 Amp Wye)
Note: Test Voltage 1500VAC one minute, line to ground.Insulation Resistance: 300 MΩ min. at 500VDC.Voltage Drop: 1V max. at rated current.Weight: 8.82 ounces (250 grams) for 63-PMF-030-8-14 and 63-PMF-080-8-14
19.4 ounces (550 grams) for 62-PMB-050-6-1251.5 ounces (1450 grams) for 63-PMF-160-9-21
Pow
er L
ine
Filt
ers
88 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Specifications
62-PMB-050-6-12
63-PMF-030-8-14
63-PMF-080-8-14
63-PMF-160-9-21
ModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) CY CX (L1) Rise (Max.)
250VAC
420VAC
5A
3A
8A
16A
0.6mA
1.0mA
3.0mA
45°C
30°C
40°C
45°C
115mH
1.0mH (4X)
0.74mH (4X)
1.2mH (4X)
0.22uF
470uF (3X)
1.0uF (6X)
2200pF
4700pF (4X)
0.015uF (2X)
62-PMB/63-PMF Series
Power Line FiltersThree PhaseLow Current/High Performance
Temperature Characteristics
BL
BL BK
BK
4.444 (113)4.050 (103)
3.585 (91.2).547(13.9)
.547(13.9)
.983(25)
2 - .197(ø5) Hole
Fast-ontab #250
1.809(46)
.208(5.3)
2.045(52)
.629(16)
.708(18)
1.376 (35)
5 — .157(M4)
2.753 (70)
.865 (22)
.865 (22)
3.460(88)
3.539(90)
.039 (1)
.944 (24)* General tolerance ±.020 (0.5)
Common Mode
63-PMF-030-8-14 and 63-PMF-080-8-14 (3 and 8 Amp)
62-PMB-050-6-12 (5 Amp)
63-PMF-160-9-21 (16 Amp)
Normal Mode
Dimensions in inches (mm)
63-PMF-030-8-14
63-PMF-160-9-21
63-PMF-080-8-14
63-PMB-050-8-12
63-PMF-030-8-14
63-PMF-160-9-21
63-PMF-080-8-14
63-PMB-050-8-12
62-PMB-050-6-12 (5 Amp)
63-PMF (3, 8 and 16 Amp)
62-PMB-050-6-12 (5 Amp)
63-PMF (3, 8 and 16 Amp)
Fast ontab #250
.350 (8.9)
.350 (8.9)
.350 (8.9)
4.404(112)
5.112 (130.0)5.702 (145 ± 0.5)6.292 (160)
4 - .216(ø5.5) Hole
.362(9.2)
4.286(109)
3.146(80.0±0.5)
* General tolerance ±..059 (1.5)
Fast ontab #250(Groundtab)
.708(18)
1.494 (38)2.359 (60)
Pow
er L
ine
Filt
ers
89SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
62-PMB/63-PMF Series
Figure
A
B
A
B
C
RatedCurrent
5A
10A
15A
20A
25A
30A
Model
13-PWF-005-12-H
13-PWL-005-12-C
13-PWF-010-12-H
13-PWL-010-12-C
13-PWB-010-12-D
13-PWB-015-12-D
13-PWB-020-12-D
13-PWB-025-12-D
13-PWB-030-12-D
90 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line FiltersThree Phase
Features Excellent attenuation for high voltage impulse Effective for both balanced and unbalanced
three-phase loads Metal case provides effective EMI shielding Epoxy molded for internal component reliability Suitable for both Wye and Delta connection Excellent filtering characteristics for both normal
and common mode Operating temperature: -40°C to +85°C Designed for 3-phase 4-line power supply systems
Applications Digital equipment Industrial equipment (UPS, inverters
and converters) Automation equipment Computerized washing machines
Circuit DiagramCircuit 1
A
B
C
NG
A'
B'
C'
N'
A
B
C
NG
A'
B'
C'
N'
Circuit 2
Note: Test Voltage 1500VAC one minute, line to ground.Insulation Resistance: 300 MΩ min. at 500VDC.Voltage Drop: 1V max. at rated current.
Pow
er L
ine
Filt
ers
SpecificationsRated Voltage(@ 50/60Hz)
440/250VAC
LeakageCurrent (Max.)
1.5mA
Temperature Rise(Max.)
30°C
CircuitDiagram
1
2
13-PWF/PWL/PWB Series
91SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line FiltersThree Phase
Dimensions in inches (mm)
Pow
er L
ine
Filt
ers
13-PWF/PWL/PWB Series
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Common Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Normal Mode
13-PWF-005;-010;-PWL-005;-010;-PWB-010
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
13-PWF-005-12-H13-PWL-005-12-C
13-PWF-010-12-H13-PWL-010-12-C
13-PWB-010-12-D
13-PWB-015;-020;-025:-030
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
13-PWB-015-12-D13-PWB-020-12-D13-PWB-025-12-D
13-PWB-030-12-D
13-PWF-005;-010;-PWL-005;-010;-PWB-010
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
13-PWF-005-12-H13-PWL-005-12-C
13-PWF-010-12-H13-PWL-010-12-C
13-PWB-010-12-D
13-PWB-015;-020;-025:-030
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
13-PWB-015-12-D13-PWB-020-12-D13-PWB-025-12-D
13-PWB-030-12-D
5.3 (135)
3.9 (98.5)
2.0 (51)
Figure CFigure A
Figure B
Figure
A
B
A
B
C
RatedCurrent
5A
10A
15A
20A
25A
30A
Model
13-PDF-005-11-J
13-PDL-005-11-D
13-PDF-010-11-J
13-PDL-010-11-D
13-PDB-010-11-D
13-PDB-015-11-D
13-PDB-020-11-D
13-PDB-025-11-D
13-PDB-030-11-D
92 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line FiltersThree Phase
Features Excellent attenuation for high voltage impulse Effective for both balanced and unbalanced
three-phase loads Metal case provides effective EMI shielding Epoxy molded for internal component reliability Compact and economical Excellent filtering characteristics for both normal
and common mode Operating temperature: -40°C to +85°C Designed for 3-phase, 3-Delta connection system
Applications Digital equipment Industrial equipment (UPS, inverters
and converters) Automation equipment Switching power supplies
Circuit Diagram
A
B
C
G
A'
B'
C'
A
B
C
G
A'
B'
C'
Circuit 1
Circuit 2
Note: Test Voltage 1500VAC one minute, line to ground.Insulation Resistance: 300 MΩ min. at 500VDC.Voltage Drop: 1V max. at rated current.
Pow
er L
ine
Filt
ers
SpecificationsRated Voltage(@ 50/60Hz)
440/250VAC
LeakageCurrent (Max.)
1.5mA
Temperature Rise(Max.)
30°C
CircuitDiagram
1
2
13-PDF/PDL/PDB Series
Ø .177 (4.5) (2X)
3.35 (85)
2.95 (75)
2.52 (64)1.06(27)
2.00(51)
M4THREAD(10X)
5.31 (135)
3.88 (98.5)2.00 (51)
1.51(38.5)
3.31(84)
3.74(95)
4.13(105)
.117 (4.5)
.25 (6.3)Ø .177 (4.5) (2X)
3.35(85)
3.15 (80)
2.00(51)
1.42(36)
2.91(74)
2.52(64)
93SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line FiltersThree Phase
Dimensions in inches (mm)
Pow
er L
ine
Filt
ers
13-PDF/PDL/PDB Series
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Common Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Normal Mode
13-PDF-005;-010; PDL-005;-010 PDB-010
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
13-PDF-005-11-J13-PDL-005-11-D
13-PDF-010-11-J13-PDL-010-11-D
13-PDB-010-11-D
13-PDB-015;-020;-025:-030
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
13-PDB-015-11-D13-PDB-020-11-D13-PDB-025-11-D
13-PDB-030-11-D
13-PDF-005;-010; PDL-005;-010 PDB-010
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
13-PDF-005-11-J13-PDL-005-11-D
13-PDF-010-11-J13-PDL-010-11-D
13-PDB-010-11-D
13-PDB-015;-020;-025:-030
Inse
rtio
n Lo
ss (d
B)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 1 2 5 10 20 50
13-PDB-015-11-D13-PDB-020-11-D13-PDB-025-11-D
13-PDB-030-11-D
Figure C
Figure B
Figure A
RatedCurrent
5A
10A
20A
35A
50A
80A
100A
150A
Model
13-PWB-005-12-A
13-PWB-010-12-B
13-PWB-020-12-B
13-PWB-035-12-C
13-PWB-050-13-C
13-PWB-080-14-D
13-PWB-100-14-D
13-PWB-150-14-E
A
B
C
NG
A'
B'
C'
N'
A
B
C
NG
A'
B'
C'
N'
Circuit 1
Circuit 2
Power Line FiltersThree PhaseHigh Performance
Features Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Epoxy molded for internal component reliability Excellent filtering characteristics for both normal
and common mode Various current ratings available: from 5 to 150 Amps Operating temperature: -40°C to +85°C Designed for 3-phase, 4-line power systems
Applications Power supplies for data systems Industrial equipment (UPS, inverters
and converters) Automation equipment Telecommunications systems and equipment
Circuit Diagram
Note: Test Voltage 1500VAC one minute, line to ground.Insulation Resistance: 300 MΩ min. at 500VDC.Voltage Drop: 1V max. at rated current.
Pow
er L
ine
Filt
ers
94 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
SpecificationsRated Voltage(@ 50/60Hz)
440/250VAC
LeakageCurrent (Max.)
4.5mA
9.0mA
20mA
Temperature Rise(Max.)
30°C
CircuitDiagram
1
2
13-PWB Series
AB
C
E
L
M
G
D
H P
F
K
NJ
I
Power Line FiltersThree PhaseHigh Performance
Dimensions in inches (mm)
Pow
er L
ine
Filt
ers
95SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
13-PWB Series
DimensionsModel
13-PWB-005-12-A
13-PWB-010-12-B
13-PWB-020-12-B
13-PWB-035-12-C
13-PWB-050-13-C
13-PWB-080-14-D
13-PWB-100-14-D
13-PWB-150-14-E
A
7.2 (184)
9.6(243)
13.9(354)
B
6.3 (160)
8.7(220)
12.6(320)
C
7.9 (202)
10.3(261)
15.1(384)
D
2.4(60)
3.1(81)
3.9(99)
E
1.7(44)
3.8(96)
6.1(155)
7.5 (190)
F
3.5 (86)
3.9(100)
4.9(125)
7.3(185)
8.7 (220)
G
.70 (18)
.98(25)
1.2(30)
1.4 (35)
H
2.3 (58)
3.5(90)
3.9 (100)
I
M4
M6
M8
J
1.5 (38)
1.8(45)
2.3(58)
2.4(62)
M
–
2.9(74)
3.4(86)
K
–
M4
N
–
1.9(49)
2.2(56)
2.4 (61)
P
M4
M6
M8
L
.25 x .37 (6.4 x 9.4)
.25 x .37 (6.4 x 9.5)
.25 x .38 (6.4 x 9.6)
.25 x .38 (6.4 x 9.7)
.25 x .38 (6.4 x 9.8)
.25 x .39 (6.4 x 9.9)
.25 x .36 (6.4 x 9.10)
.25 x .36 (6.4 x 9.11)
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Common Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Normal Mode
13-PWB-005;-010;-020;-035
Inse
rtio
n Lo
ss (d
B)
120
Frequency (MHz)
105
90
75
60
45
30
15
00.1 0.2 0.5 1 2 5 10 20 50
13-PWB-005-12-A
13-PWB-020-12-A
13-PWB-035-12-A
13-PWB-010-12-A
13-PWB-050;-080;-100;-150
Inse
rtio
n Lo
ss (d
B)
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
120
105
90
75
60
45
30
15
0
13-PWB-050-13-C
13-PWB-080-14-D
13-PWB-100-14-D
13-PWB-150-14-E
13-PWB-005;-010;-020;-035
Inse
rtio
n Lo
ss (d
B)
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
120
105
90
75
60
45
30
15
0
13-PWB-005-12-A
13-PWB-020-12-A
13-PWB-035-12-A
13-PWB-010-12-A
Inse
rtio
n Lo
ss (d
B)
Frequency (MHz)
0.1 0.2 0.5 1 2 5 10 20 50
13-PWB-050;-080;-100;-150120
105
90
75
60
45
30
15
0
13-PWB-050-13-C
13-PWB-080-14-D13-PWB-100-14-D
13-PWB-150-14-E
RatedCurrent
5A
10A
20A
35A
50A
80A
100A
150A
200A
Model
13-PDB-005-12-A
13-PDB-010-12-A
13-PDB-020-12-B
13-PDB-035-12-B
13-PDB-050-13-B
13-PDB-080-13-C
13-PDB-100-14-C
13-PDB-150-14-C
13-PDB-200-14-D
A
B
C
G
A'
B'
C'
A
B
C
G
A'
B'
C'
Circuit 1
Circuit 2
Power Line FiltersThree PhaseHigh Performance
Features Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Epoxy molded for internal component reliability Excellent filtering characteristics for both normal
and common mode Various current ratings available: from 5 to 200 Amps Operating temperature: -40°C to +85°C Designed for 3-phase, 3-line connection systems
Applications Digital equipment Industrial equipment (UPS, inverters
and converters)
Circuit Diagram
Note: Test Voltage 2250VDC one minute, line to ground.Insulation Resistance: 500MΩ.
Pow
er L
ine
Filt
ers
96 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
SpecificationsRated Voltage(@ 50/60Hz)
440/250VAC
LeakageCurrent (Max.)
4.5mA
9.0mA
20mA
Temperature Rise(Max.)
30°C
CircuitDiagram
1
2
13-PDB Series
AB
C
E
L
M
I
G
D
H P
F
KNJ
Power Line FiltersThree PhaseHigh Performance
Dimensions in inches (mm)
Pow
er L
ine
Filt
ers
97SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
13-PDB Series
DimensionsModel
13-PDB-005-12-A
13-PDB-010-12-A
13-PDB-020-12-B
13-PDB-035-12-B
13-PDB-050-13-B
13-PDB-080-13-C
13-PDB-100-14-C
13-PDB-150-14-C
13-PDB-200-14-D
A
7.2(184)
9.6(243)
13.9(354)
B
6.3(160)
8.7(220)
12.6(320)
C
7.9(202)
10.3(261)
15.1(384)
D
1.6(42)
2.3(58)
2.5(66)
E
2.4(60)
2.7(70)
6.1(155)
7.5 (190)
F
3.3(86)
3.9(100)
7.3(185)
8.6 (220)
G
.70(18)
.98(25)
1.2(30)
1.4 (35)
H
2.3(58)
3.5(90)
3.9 (100)
I
M4
M6
M8
J
1.5(38)
2.3(58)
2.4(62)
M
–
2.9(74)
3.3(86)
K
–
M4
N
–
1.9(49)
2.2(56)
2.4 (61)
P
M4
M6
M8
L
.25 x .37 (6.4 x 9.4)
.25 x .37 (6.4 x 9.5)
.25 x .38 (6.4 x 9.6)
.25 x .38 (6.4 x 9.7)
.25 x .38 (6.4 x 9.8)
.25 x .39 (6.4 x 9.9)
.25 x .36 (6.4 x 9.10)
.25 x .36 (6.4 x 9.11)
.25 x .36 (6.4 x 9.12)
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
Common Mode
50ΩLevelMeter50Ω
1 32 4
Filter
Oscillator50Ω
50Ω
Normal Mode
13-PDB-005;-010;-020;-035
Inse
rtio
n Lo
ss (d
B)
120
Frequency (MHz)
105
90
75
60
45
30
15
0
13-PDB-010-12-A
13-PDB-020-12-B
13-PDB-035-12-B
13-PDB-005-12-A
0 0.01 0.02 .1 1 10 20 30 60
13-PDB-050;-080;-100;-150;-200
Inse
rtio
n Lo
ss (d
B)
Frequency (MHz)
120
105
90
75
60
45
30
15
0
13-PDB-050-13-B
13-PDB-080-13-C
13-PDB-100-14-C
13-PDB-150-14-C
13-PDB-200-14-D
0 0.01 0.02 .1 1 10 20 30 60
13-PDB-005;-010;-020;-035
Inse
rtio
n Lo
ss (d
B)
Frequency (MHz)
120
105
90
75
60
45
30
15
0
13-PDB-010-12-A
13-PDB-020-12-B
13-PDB-035-12-B
13-PDB-005-12-A
0 0.01 0.02 .1 1 10 20 30 60
Inse
rtio
n Lo
ss (d
B)
Frequency (MHz)
13-PDB-050;-080;-100;-150;-200120
105
90
75
60
45
30
15
00 0.01 0.02 .1 1 10 20 30 60
13-PDB-050-13-B
13-PDB-080-13-C
13-PDB-100-14-C
13-PDB-150-14-C
13-PDB-200-14-D
98 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Military/AerospaceMultisection Filters
Mili
tary
/Aer
ospa
ce M
ultis
ectio
n Fi
lter
s
The High Performance Power Line Filters shown on pages99 through 105 are designed to meet the following criteria.
The information shown can be used as a basis for filter specifications. (Contact factory for additional details).
OrderTest of Examination Test Method Post Test
Group Test or Test (Per MIL-STD-202) Requirements
1 Voltage Drop Paragraph 4.6.8 of MIL-F-15733 Three percent of rated voltage max.
2 Leakage Current UL 1283 Per applicable specification
3 Temperature Rise MIL-F-15733 Paragraph 4.6.4 25°C max.
4 Terminal Strength Method 211, Condition ANo evidence of loosening or rupture.5 lb. applied force. Line Cords: 35 Lbs.
1 Shock, Medium Impact Method 213, Condition G Must pass DWV and Insertion Loss
2 Vibration, High Frequency Method 204, Condition A Monitor for shorts or open
3 Thermal Shock Method 107, Test Condition A Pass 90% DWV IR to be 30% of initial
4 HumidityMethod 107, Condition B, except
Pass 90% DWV IR to be 30% of initialtemperature equals 25°C
1 LifeMethod 108, Condition D 1.2 x Rated AC voltage Pass 90% DWV insulation resistanceat max. operating temp. or 1.4 x DC voltage to be 30% of initial.
IIA
IIB
III
Features High common and differential mode attenuation Standard designs up to 100 Amps Excellent insertion loss characteristics up to 1 GHz Voltage rating 115-250VAC and 400VDC up to 400 Hz Available to meet MIL-F-15733 and MIL-STD-461
standards Available to meet TEMPEST and FCC requirements Custom designs available
Applications Military Ruggedized computers Commercial & Radar
military/aerospace Electronic warfare Secured communications Ground/air weapon systems Switching power supplies Satellites Data processing equipment
Test Specifications
99SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Military/AerospaceMultisection Filters
Mili
tary
/Aer
ospa
ce M
ultis
ectio
n Fi
lter
s
52-600-001 5A 120/240VAC -40°C to +65°C .20 1 mA COMM 33 65 80 80 80 80 60
60 Hz DIFF 37 65 80 80 80 – –
52-600-002 10A 120/240VAC -40°C to +65°C .10 1 mA COMM – 50 70 80 80 70 60
60 Hz DIFF 25 50 75 80 80 – –
DCR. LeakageCurrent Voltage Temperature max. Current Mode
Model Rating Rating Rating (ohms) (max.) (max.)
Minimum Insertion Loss(db) Per MIL-STD-220
50K 150K 300K 1M 10M 100M 1G
Consult factory for UL/CSA approval availability.
LINE LOAD
Circuit Schematic
Insertion Loss52-600-001
60
40
20
0
Inse
rtio
n Lo
ss (d
B)
0.01 0.1 1 10 100 1000Frequency (MHz)
80
common mode
differential mode
52-600-002
60
40
20
0
Inse
rtio
n Lo
ss (d
B)
0.01 0.1 1 10 100 1000Frequency (MHz)
80
common mode
differential mode
.215(5.46) 1.250
(31.75)
.240(6.10)
2.500(63.50)
SWITCH
FUSECONNECTOR
.625(15.8)
1.68(42.67)
#6-32 THREADEDINSERTS (4 PL.)(3.50-32)
2.98(75.70)
.250 Fast-on tabs (3 PL.)
3.88(98.55)
.03 R. 4 PL
CHASSISMOUNTINGHOLE
2.120 ± .010(53.85) 2.500
(63.50)
1.250(31.75)
.250(6.35)
52-600-00152-600-002
Dimensions
Dimensions in inches (mm)
100 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
HIGH PERFORMANCE
Power Line Filters for C.O.T.S./TEMPEST Applications
52-523-002 5A 120/240VAC -40°C to +65°C .25 1 mA COMM – 55 60 80 80 70 60
60 Hz DIFF – 50 60 80 80 – –
DCR LeakageCurrent Voltage Temperature max. Current Mode
Model Rating Rating Rating (ohms) (max.) (max.)
Minimum Insertion Loss(db) Per MIL-STD-220
50K 150K 300K 1M 10M 100M 1G
Consult factory for UL/CSA approval availability.
Circuit Schematic
LINE LOAD
52-523-002
.600 (15.24)
.750 (19.05)
.250 (6.35)
.250 (6.35)
3.000 (76.2)
2.010 (51.05)
.375 (9.52)
#6-32 THDED
INSERT 4 PLCS. (3.50-32)
.625 (15.8)
1.25 (31.75)
3.50 (88.9) .875
(22.2)
.875 (22.2)
1.75 (44.4)
4.00 (101.6)
PLUG
FUSE-HOLDER
# 52-600-00152-600-002
Dimensions
Military/AerospaceMultisection Filters
52-523-002Insertion Loss
52-523-002
60
40
20
0
Inse
rtio
n Lo
ss (d
B)
0.01 0.1 1 10 100 1000Frequency (MHz)
80
Dimensions in inches (mm)
Mili
tary
/Aer
ospa
ce M
ultis
ectio
n Fi
lter
s
101SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Military/AerospaceMultisection Filters
1212-0502 10A 350VDC -55°C to +125°C .01 1 mA 5000pF 20 65 70 70
240VAC 60 Hz
DCR LeakageCurrent Voltage Temperature max. Current Cx
Model Rating Rating Rating (ohms) (max.) Value
Minimum Insertion Loss(db) Per MIL-STD-220
10M 100M 500M 1G
Consult factory for UL/CSA approval availability.
Insertion Loss1212-0502
60
40
20
0
Inse
rtio
n Lo
ss (d
B)
0.01 0.1 1 10 100 1000Frequency (MHz)
80
Circuit Schematic1212-0502
Dimensions
Dimensions in inches (mm)
Mili
tary
/Aer
ospa
ce M
ultis
ectio
n Fi
lter
s
1212-0502
1.437 ± .031(36.50 ± .78)
.875(22.23)
1.250(31.75)
.187(4.75)
.209(5.31)
.418(10.62)
.500(12.7)
.219 TYP. (5.56)
.656(16.41)
.125
1.000(25.4)
1.187 ± .015(30.15 ± .38)
(3.18 ± .00)6-PLCS.
.281 ± .031(7.14 ± .78)
.055 TYP. (1.40)
.105 TYP. (2.67)
.120 TYP. (3.05)
MOUNTING SURFACE .032 (.81)
.710 (18.03)
.594± .031± (.78)
1.125(28.58)
102 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Military/AerospaceMultisection FiltersMilitary/AerospaceMultisection Filters
Insertion Loss52-378-002, -004 MIL-STD-220
60
40
20
0
Inse
rtio
n Lo
ss (d
B)
0.01 0.1 1 10 100 1000Frequency (MHz)
80
.750(19.05)
1.500(38.10)
2.50(63.50)
#8-32 UNC THD. INSERTS(4.17-32).350 DEEP, 2 PLACES(8.89)
1.25(31.75)
2.50(63.50)
CONNECTOR #8001-14S-7P-A3MATES WITH MS-3106-14S-7S
1.75(44.45)
Minimum Insertion Loss (db)
50 150 300 1 10 100 1KHz KHz KHz MHz MHZ MHZ GHz
52-378-001 3 Amps 240VAC 60 Hz -55°C to 85°C .3 50 mA A 30 60 70 80 80 70 70Line to Line
52-378-002 5 Amps 240VAC 60 Hz -55°C to 85°C .2 50 mA B 24 64 70 80 80 70 70Line to Line
52-378-004 5 Amps 240VAC 60 Hz -55°C to 85°C .2 50 mA A 34 64 70 80 80 70 70Line to Line
52-378-005 3 Amps 240VAC 60 Hz -55°C to 85°C .3 50 mA B 40 70 80 80 80 70 60Line to Line
DCR LeakageCurrent Voltage Temperature max. Current
Model Rating Rating Range (ohms) (max.) Schematic
Spectrum's electromagnetic compatibility expertise in the secure communication or “TEMPEST” arena is rep-resented by this group of high performance filters. Theseunits are especially well suited for use in MIL-STD-461applications to reduce conducted emissions. The filtersare manufactured with glass sealed terminalsand connectors.
Features Excellent insertion loss profile Available for DC & AC applications up to 400 Hz Available for 3-14 Amp applications Custom systems can be designed
to your specific needs QPL to MIL-F 15733/63-0001
52-378-002
LINE LOAD
A
C
B
A
C
B
A
C
B
A
C
B
LINE LOAD
Filter Schematic A
Filter Schematic B
Dimensions in inches (mm)
Dimensions
Secure Communications
Mili
tary
/Aer
ospa
ce M
ultis
ectio
n Fi
lter
s
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
103
Power Line Filtersfor Secure Communications
Minimum Insertion Loss (db)
50 150 300 1.0 10 100 1KHz KHz KHz MHz MHz MHz GHz
52-387-010 1 10 Amps 240VAC 60 Hz -55°C to 85°C .2 50 mA C common 24 60 70 80 80 70 70Line to Line
common 34 64 70 80 80 70 70
52-387-012 1 5 Amps240VAC 400 Hz
-55°C to 85°C .2 5 mA DLine to Line differential 30 30 70 80 80 – –
52-409-001 2 14 Amps 240VAC 60 Hz -55°C to 85°C .04 50 mA E common 14 30 45 80 80 70 60Line to Line
DCR LeakageCurrent Voltage Temperature max. Current
Model Fig. Rating Rating Range (ohms) (max.) Sch. Mode
Figure 1 Figure 2
.750(19.05)
1.500(38.10)
2.50(63.50)
#8-32 UNC THD. INSERTS(4.17-32).350 DEEP, 2 PLACES(8.89)
1.25(31.75)
2.50(63.50)
CONNECTOR #8001-10SL-3PN-FP-A3MATES WITH MS-3106-10SL-3S
3.00(76.20)
1.25(31.75)
.750(19.05)
1.500(38.10)
2.50(63.50)
#8-32 UNC THD. INSERTS(4.17-32).350 DEEP, 2 PLACES(8.89)
1.25(31.75)
2.50(63.50)
.625(15.87)
#8-32 UNC(4.17-32)STUD
CONNECTOR #8001-14S-7P-A3MATES WITH MS-3106-14S-7S
1.75(44.45)
Filter Schematic C
Filter Schematic D
Filter Schematic E
A
C
B
A
C
B
LINE LOAD
A
C
B
A
C
B
LINE LOAD
A
C
B
A
C
B
LINE LOAD
52-387-010, -003 MIL-STD-22052-409-001 MIL-STD-220
60
40
20
0
Inse
rtio
n Lo
ss (d
B)
0.01 0.1 1 10 100 1000Frequency (MHz)
80
52-409-001MIL-STD-220
52-387-010,-003 MIL-STD-220
Insertion Loss
Dimensions in inches (mm) Dimensions in inches (mm)
Dimensions
Military/AerospaceMultisection Filters
Mili
tary
/Aer
ospa
ce M
ultis
ectio
n Fi
lter
s
3 Phase and 400 Hz models available.Please consult the factory.
104 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Military/AerospaceMultisection Filters
Features Meets applicable sections of MIL-F-15733 Excellent performance Integral IEC connector Available with integral fused IEC connector
and two pole switch Current ratings to 15 Amps Custom designs available Designed to meet TEMPEST requirements
Electrical SpecificationsRated current ranges .................. 3, 6, 10, 15 Amps
Rated voltage............................. 115-250VAC
Operating frequency................... 50-60 Hz
Maximum leakage current@115VAC 60 Hz............ 1.2 mA
@250VAC 50 Hz............ 2.5 mA
Test voltageLine-to-Line.................... 1450VDC
Line-to-Ground............... 2250VDC
Part Numbering System:
Insertion Loss
Common Mode (CM) is tested in a 50 ohm system with all lines tied together on the line and load sides of the filter.Differential Mode (DM) is tested in a 50 ohm system using a 180˚ phase splitter on both sides of the filter.
760 A 06 Q-
Model
Current Rating:3, 6, 10, 15 Amps
Terminal Style:A=.25 Quick ConnectC=Wire Leads (4" min.)
Series: 760; 761 or 762
760, 761, 762 - 3, 6 Amps
60
40
20
0
Inse
rtio
n Lo
ss (d
B)
0.01 0.1 1 10 100 1000Frequency (MHz)
80common mode
differential mode
760, 761, 762 - 10, 15 Amps
60
40
20
0
Inse
rtio
n Lo
ss (d
B)
0.01 0.1 1 10 100 1000Frequency (MHz)
80common mode
differential mode
Secure Communications
Mili
tary
/Aer
ospa
ce M
ultis
ectio
n Fi
lter
s
105SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Military/AerospaceMultisection Filters
B
3, 6, 10, AMPFRONT PANEL
15 AMPFRONT PANEL
Switch Omittedin Model 761
6-32 UNC-2B(6 Places)
Switch Omittedin Model 761
1.30(33.02)
0.20(5.08)
1.875(47.62)
0.80(20.32)
3.67(93.21)
0.80(20.32)
0.20 (5.08)
3.00(76.2)
C
.40 (10.16)
.55 (13.97)
A1.30
(33.02)
Dimensions - 761, 762 Series
TERMINATIONSTYLE “A” STYLE “C”
B
1.312(33.32)
.66 (16.67)
1.332(33.83)
.67 (42.41)
8-32 Inserts (4 Places)
C
.95 (24.13)
.13 (3.30)
.55 (13.97)
A
1.23(31.24)
TERMINATION
Dimensions - 760 Series
Dimensions in inches (mm)
Dimensions in inches (mm)
Current Filter DimensionsSeries Rating
(Amps) A B C
3, 62.25 3.00 1.88
760(57.15) (76.20) (47.75)
10, 155.50 3.15 2.10
(139.70) (88.01) (53.34)
Current Filter DimensionsSeries Rating
(Amps) A B C
761, 762 3, 62.55 2.97 1.88
(64.77) (75.43) (47.75)
761 10, 155.50 3.15 2.10
(139.70) (88.01) (53.34)
762 10, 155.75 3.15 2.10
(146.05) (88.01) (53.34)
Mili
tary
/Aer
ospa
ce M
ultis
ectio
n Fi
lter
s
Custom/ApplicationSpecific Filters
Cus
tom
/App
lica
tion
Spe
cifi
c Fi
lter
s
SpectrumControl will address virtually any requirement fora custom power product. Our many years of experience inproviding EMI/RFI solutions has allowed us to satisfy bothglobal EMC regulations and time-to-market constraints.Spectrum Control’s engineering expertise and verticalintegration reduces your speed-to-market, as well assaves you money.
Features/Benefits Incorporates filtering and custom circuitry into one
design package SCI’s EMC Test Facility will define compliance issues Current and voltage ratings to meet your specifications Specific circuit designs to accommodate your application Reduces your development time Increases speed-to-market Designed to perform in industrial environments Designs incorporate filtering for both common and
differential modes Ensures reliability (all parts are 100% tested) Designed to meet agency approvals
Options EMI filtering Power distribution Transient protection Indicator lights Circuit breaker protection Leads or studs Voltage cut-off Agency approvals Reverse polarity
Performance CharacteristicsInsertion loss range Effective filtering from 10 KHz to
10 MHz with proper installation
Current ratings (max.) up to 500 Amps
Voltage ratings (max.) 400VDC and 240VAC standard, custom ratings available
Leakage current ratings Varies, low leakage designs available
Temperature -25° C to +85° C
Specify your required current rating, voltage ratingsand capacitance value.
106 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
EMI Filtering
Custom/ApplicationSpecific Filters
Cus
tom
/App
lica
tion
Spe
cifi
c Fi
lter
s
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
107
Power Distribution
EMI Filtering
Transient Protection
Power Entry
-48 VDC-60 VDC
Low Voltage Cut-off UL Recognized Complies to UL 1459
CSA Certified
Custom Ground Plate
CircuitBreakerProtection
PowerDistribution
MultipleOutlets
Three-Phase Delta EMI Filter
High CurrentTerminal Block
Pigtail Leads
RuggedConstruction
Custom/ApplicationSpecific Filters
Cus
tom
/App
lica
tion
Spe
cifi
c Fi
lter
s
108 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Spectrum Control's design teams can help transform a functional electronic design into an easy to install EMI filtered package containing all required components.We will define your EMC problem through our test facilities, develop a filter solution and manufacture product to meet your schedule.
By designing and manufacturingyour entire assembly,Spectrum Control will: Reduce development time Combine your design into a compact, filtered package Simplify installation, saving time and money Increase productivity Complement your inventory control program Reduce your vendor base
PowerLine Filters
Custom/ApplicationSpecific Filters
Cus
tom
/App
lica
tion
Spe
cifi
c Fi
lter
s
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
109
Remote control options available with intelligent powerdistribution units.
Single Line Filters
FilteredTerminal Blocks
Power Distribution Units
PSM High CurrentSurface Mount Filters
Part Number Index
Spectrum part # . . . . . . . . . . .Page
10-BPF-XXX-2-X . . . . . . . . . . . . . .3210-BPF-XXX-5-X . . . . . . . . . . . . . .3010-BPL-XXX-5-X . . . . . . . . . . . . . .3811-MPC-XXX-X-X . . . . . . . . . . . . .5812-MMB-XXX-5-X . . . . . . . . . . . . .8212-MMB-XXX-5-X . . . . . . . . . . . . .8612-MMB-XXX-11-X . . . . . . . . . . . .8412-MMF-XXX-5-X . . . . . . . . . . . . .8212-MMF-XXX-5-X . . . . . . . . . . . . .8612-MMF-XXX-11-X . . . . . . . . . . . .8412-PMB-XXX-DC-X . . . . . . . . . . . .7812-PMB-XXX-X-X . . . . . . . . . . . . .7612-PMF-XXX-DC-X . . . . . . . . . . . .7812-PMF-XXX-2-X . . . . . . . . . . . . .6612-PMF-XXX-5-X . . . . . . . . . . . . .7212-PML-XXX-X-X . . . . . . . . . . . . .6613-PDB-XXX-XX-X . . . . . . . . . . . .9213-PDB-XXX-XX-X . . . . . . . . . . . .9613-PDF-XXX-XX-X . . . . . . . . . . . .9213-PDL-XXX-XX-X . . . . . . . . . . . .9213-PWB-XXX-XX-A . . . . . . . . . . . .9413-PWB-XXX-XX-B . . . . . . . . . . . .9413-PWB-XXX-XX-C . . . . . . . . . . . .9413-PWB-XXX-14-D . . . . . . . . . . . .9413-PWB-XXX-XX-E . . . . . . . . . . . .9413-PWB-010-12-D . . . . . . . . . . . . .9013-PWB-015-12-D . . . . . . . . . . . . .9013-PWB-020-12-D . . . . . . . . . . . . .9013-PWB-025-12-D . . . . . . . . . . . . .9013-PWB-030-12-D . . . . . . . . . . . . .9013-PWF-XXX-XX-X . . . . . . . . . . . .9013-PWL-XXX-XX-X . . . . . . . . . . . .9052-226-001 . . . . . . . . . . . . . . . . . .2052-226-002 . . . . . . . . . . . . . . . . . .2052-226-004 . . . . . . . . . . . . . . . . . .2052-226-006 . . . . . . . . . . . . . . . . . .2052-226-008 . . . . . . . . . . . . . . . . . .2052-226-009 . . . . . . . . . . . . . . . . . .2052-226-011-XX . . . . . . . . . . . . . . .1252-226-015 . . . . . . . . . . . . . . . . . .20
Spectrum part # . . . . . . . . . . .Page
52-226-016-XX . . . . . . . . . . . . . . .1652-226-019-XX . . . . . . . . . . . . . . .1852-226-020-XX . . . . . . . . . . . . . . .1452-226-021-XX . . . . . . . . . . . . . . .1252-226-026-XX . . . . . . . . . . . . . . .1652-226-029-XX . . . . . . . . . . . . . . .1452-226-031-XX . . . . . . . . . . . . . . .1252-226-036-XX . . . . . . . . . . . . . . .1652-226-037-XX . . . . . . . . . . . . . . .1852-226-041-XX . . . . . . . . . . . . . . .1252-226-046-XX . . . . . . . . . . . . . . .1652-267-002 . . . . . . . . . . . . . . . . . .2052-267-003 . . . . . . . . . . . . . . . . . .2052-267-008 . . . . . . . . . . . . . . . . . .2052-267-009 . . . . . . . . . . . . . . . . . .2052-267-010 . . . . . . . . . . . . . . . . . .2052-267-011 . . . . . . . . . . . . . . . . . .2052-267-012 . . . . . . . . . . . . . . . . . .2052-378-XXX . . . . . . . . . . . . . . . .10252-387-XXX . . . . . . . . . . . . . . . .10352-409-XXX . . . . . . . . . . . . . . . .10352-523-002 . . . . . . . . . . . . . . . . .10052-600-XXX . . . . . . . . . . . . . . . . .9952-1013-XXX . . . . . . . . . . . . . . . .2360-BHP-XXX-X-X . . . . . . . . . . . . .5660-BHS-XXX-X-X . . . . . . . . . . . . .2860-BPF-XXX-X-X . . . . . . . . . . . . .2660-BPL-XXX-X-X . . . . . . . . . . . . . .3660-BPP-XXX-X-X . . . . . . . . . . . . .5460-BPR-XXX-X-X . . . . . . . . . . . . .2460-BPS-XXX-X-X . . . . . . . . . . . . .2460-SPL-XXX-X-X . . . . . . . . . . . . . .3460-SPR-XXX-X-X . . . . . . . . . . . . .4060-SPS-XXX-X-X . . . . . . . . . . . . .4061-MPC-XXX-X-XX . . . . . . . . . . . .5262-AFC-XXX-X-XX . . . . . . . . . . . .6062-AFL-XXX-X-XX . . . . . . . . . . . . .6062-LMF-XXX-X-XX . . . . . . . . . . . .6862-LMB-XXX-X-XX . . . . . . . . . . . .6862-MMF-XXX-X-XX . . . . . . . . . . . .80
Spectrum part # . . . . . . . . . . .Page
62-PMB-XXX-5-XX . . . . . . . . . . . .7062-PMB-XXX-6-XX . . . . . . . . . . . .8862-PMB-XXX-X-XX . . . . . . . . . . . .7462-PMF-XXX-5-XX . . . . . . . . . . . .7062-PML-XXX-X-XX . . . . . . . . . . . .6462-PPF-XXX-X-XX . . . . . . . . . . . .6262-PQF-XXX-X-XX . . . . . . . . . . . .6262-PRF-XXX-X-XX . . . . . . . . . . . .6263-PMF-XXX-8-XX . . . . . . . . . . . .8863-PMF-XXX-9-XX . . . . . . . . . . . .8864-BFF-XXX-X-X . . . . . . . . . . . . . .4264-BFS-XXX-X-X . . . . . . . . . . . . .4264-BSF-XXX-X-XX . . . . . . . . . . . .4664-SSF-XXX-X-XX . . . . . . . . . . . .4665-BFF-XXX-X-X . . . . . . . . . . . . . .4265-BFS-XXX-X-X . . . . . . . . . . . . .4265-BSF-XXX-X-XX . . . . . . . . . . . .4665-SSF-XXX-X-XX . . . . . . . . . . . .4666-BFF-XXX-X-X . . . . . . . . . . . . . .4466-BFS-XXX-X-X . . . . . . . . . . . . .4466-BFS-XXX-X-X . . . . . . . . . . . . .4466-BSF-XXX-X-XX . . . . . . . . . . . .4866-SSF-XXX-X-XX . . . . . . . . . . . .4867-BFF-XXX-X-X . . . . . . . . . . . . . .4467-BFS-XXX-XX . . . . . . . . . . . . . .4467-BSF-XXX-X-X . . . . . . . . . . . . .4867-SSF-XXX-X-X . . . . . . . . . . . . .4868-BSF-XXX-X-XX . . . . . . . . . . . .50760-XXXX . . . . . . . . . . . . . . . . . .106761-XXXX . . . . . . . . . . . . . . . . . .106762-XXXX . . . . . . . . . . . . . . . . . .1061212-0502 . . . . . . . . . . . . . . . . . .101
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
110
App
endi
x
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
111
Notes
App
endi
x
Notes
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
112
App
endi
x
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
113
Design Inquiry Form
Request for Quote/Custom Design Form
Company name
Name/Title
Address
City State Zip
Phone ( ) Fax ( )
Target price
Anticipated yearly usage
Life of program
Customer Time Line (fill in dates):
Quotation
Prototype
First Article
Production Start Up
Product Offering Suggested for this Application:
(Check appropriate response)
Custom Assembly (Multi-Section Filter)
Custom Assembly (Power Distribution Unit)
Power Entry Filter
High Current Single/Dual Line Filter
Physical ParametersMechanical Requirements:
Maximum Dimensions:
Length (inches) Height (inches)
Width
Please include drawing or sketch, if available.
Electrical ParametersElectrical Terminations:
LINE SIDE LOAD SIDE
Connector
Studs
Pigtails/leads
Connector
Terminal
Block
Other
Outlet/Inlet Type: Duplex Single
IEC Vendor P/N
Other
AC Requirements: 120VAC 250VAC
Other
Frequency (Hz): 50 400
60 Other
Current (Amps): Current/ phase (Amps):
Phase requirements:
Single
Three
Delta (3 wires)
Wye (4 wires)
Other
Leakage Current: mA (max.)
DC Requirements: Voltage:
Current (Amps):
Insertion Loss Requirements: Common mode (load) (no load)
Differential mode (no load)
Accessories
SurgeSuppression: No Yes
Define
CircuitBreaker: Yes No
Current Rating
Voltage Rating
Vendor P/N
Switches: Lighted Non-lighted
Remote None
AgencyApprovals: UL CE
CSA TUV
Other
App
endi
x
&Control Products
Systems Company
A
As A Control Products & Systems Company, we strive to meet our customers’ needs by providing greatercomponent and system solutions to their design problems.Our family of interference, power and microwave products is now the broadest line in the industry. These engineeringdriven products deliver unmatched performance in the high frequencies common to new applications.
To satisfy the increased demand that corresponds with our growth, we’ve conducted a major manufacturingexpansion. This additional manufacturing capacity involves all of our facilities and is highlighted by our new plants inJuarez, Mexico and Guang Dong, China. These expandedfacilities produce components and systems for all of ourgroups and have received numerous positive customer audits.
Signal & Power Integrity GroupAs a vertically integrated producer of ceramic capacitors and filters, we continue to provide the widest range ofdiscrete EMI filters, filtered connectors, ferrite inductors and filtered power products. In addition, we have extended our ceramic technology to develop our line of wireless components. Low Pass EMI Filters Filtered Terminal Blocks
and Filter Plates Filtered Connectors Datacom Connectors Ferrite Inductors
Frequency Control GroupIn order to expand our line of microwave products, we recently acquired FSY Microwave, including all products and design expertise. The new Spectrum FSY Microwave family of SPECWAVE components and systems provides a wide range of frequency control solutions. Bandpass Filters
and Duplexers Patch Antenna
Elements Waveguide Filters Lumped Element Filters
Power Management Systems GroupSeveral years ago, we began to apply our fundamental filtering expertise to improve power management. The result is a complete line of standard, yet customizable power distribution units and remote management systems. SMARTstart AC/DC Intelligent
Power Distribution Units SHARPstart AC/DC Power Distribution Units Custom Commercial Assemblies
Ceramic Capacitors Single Line Filters Filtered Terminal Blocks Power Entry Modules
and Power Line Filters Multisection Filters
CERTIFIED
EMI Filtersand FilteredPowerProducts
FrequencyControlProducts
PowerManagementSystems
GlobalManufacturing
Suspended Substrates Cavity Filters Coaxial Tubular Filters Microwave Custom
Assemblies
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
114
Our new Check Stock system allows you to gather instant information regarding a particular component’s inventory status at Spectrum Control’s network of authorized distributors.Selecting the Check Stock icon will provide you with distributornames, part numbers, quantity on hand, online ordering capability and the last date the inventory was updated for that particular component. Use Check Stock to improve yourorganization’s efficiency by simplifying inventory managementand reducing inventory
We’ve made finding the right product for your applicationeasier than ever. By using our new online catalog you can tellus the performance parameters you need and we’ll help youlocate the appropriate product. You start by identifying yourmechanical package, add some required electrical characteristicsand we’ll show you applicable standard part numbers and howthey compare to your specifications.
New Design Direct allows you to work with our engineers in acollaborative online effort to develop a custom solution tailoredto your specific needs. After registering on our site, you’ll beable to create and track your project, entirely online. As ourengineering team makes changes to your project, you’ll receivean e-mail with a direct link to see the current status and providefeedback. Designing a custom solution has never been easier.
To see all of our new online tools,come visit us @ www.spectrumcontrol.com
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
115
AHA 12/03 20M 27-0027-0046 © Spectrum Control, Inc. Printed in U.S.A.
Corporate Headquarters
8031 Avonia RoadFairview, Pennsylvania 16415Phone: 814-474-2207Fax: 814-474-2208
Signal & Power Integrity
8061 Avonia RoadFairview, Pennsylvania 16415Phone: 814-474-1571Fax: 814-474-3110
Sales Offices
NORTH AMERICA6798 Oak Hall Lane Columbia, Maryland 21045Phone: 301-916-2919Fax: 301-916-2910
EUROPESpectrum Control GmbHHansastrasse 691126 Schwabach, GermanyPhone: (49)-9122-795-0Fax: (49)-9122-795-58
CHINASpectrum Control LimitedRoom 73-78 - 2nd FloorSino Industrial Plaza9 Kai Cheung RoadKowloon BayKowloon, Hong KongPhone: (011)-852-2197-9912Fax: (011)-852-2750-9663
For additional information regardingSpectrum Control, our full line ofEMI filtering and power productsand our many new products,call us or contact our Website athttp://www.spectrumcontrol.com
Spectrum Control, Inc. reservesthe right to alter the specificationsprovided in this publication.Consult factory for currentspecifications.
CERTIFIED
Represented or Distributed by:
&Control Products
Systems Company
A
Signal & Power Integrity Products
Ferrite beads & inductorsSurface mount filters
Discrete EMI filtersFilter plates
Filter connectorsGaskets & shieldingCeramic capacitors
Single line filtersFiltered terminal blocks
Power entry & power line filtersMilitary/multisection filters
EMC testingwww.spectrumcontrol.com
Frequency Control ProductsResonators
Bandpass filters & duplexersPatch antenna elements
Waveguide filtersCombiners
CouplersDuplexer-LNA assemblies
Lumped element filtersSuspended Substrates
Cavity filtersCoaxial tubular filters
Microwave custom assembliesTower mount amplifiers
www.specwave.com
Power Management SystemsAC/DC power distribution units
& remote reboot power management systemsCustom assemblies
Power stripswww.specpower.com
NEW
NEW
NEW
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information: API Technologies:
1212-0502