Page 1
SHEET:
REVISION:DATE:NO.
CONSTRUCTION
DOCUMENTS
EM
PL
OY
EE
F
IT
NE
SS
&
WE
LL
NE
SS
C
EN
TE
R
50
0 E
S
AN
A
NT
ON
IO
S
T.
EL
P
AS
O, T
EX
AS
20
16
-2
5 E
MP
LO
YE
E F
IT
NE
SS
&
W
EL
LN
ES
S C
EN
TE
R - C
ON
ST
RU
CT
IO
N D
OC
UM
EN
TS
DATE: SEPTEMBER 22 - 2018
M1.0
LEGEND, NOTES,
SCHEDULES
AND DETAILS
LEGEND
GENERAL NOTES
AutoCAD SHX Text
ARCHITECTS
AutoCAD SHX Text
305 LEON ST.
AutoCAD SHX Text
(915) 533-2700 t..
AutoCAD SHX Text
(915) 533-2799 f..
AutoCAD SHX Text
EL PASO, TX 79901
AutoCAD SHX Text
carldanielarchitects.com
AutoCAD SHX Text
EL PASO, TEXAS 79928
AutoCAD SHX Text
12244 RATHMORE DR.
AutoCAD SHX Text
CONSULTING MECHANICAL ENGINEERS
AutoCAD SHX Text
OFFICE: (915) 856-9420
AutoCAD SHX Text
REGISTRATION NUMBER: F-1161
AutoCAD SHX Text
JOSE A. BERNAL
AutoCAD SHX Text
was authorized by JOSE A. BERNAL
AutoCAD SHX Text
P.E. 90861. on 20 .
AutoCAD SHX Text
The seal appearing on this document
AutoCAD SHX Text
LABEL LOCATION OF ALL DAMPERS ON CEILING GRID.
AutoCAD SHX Text
ABOVE HARD CEILINGS (24in. x 24in. ACCESS DOOR).
AutoCAD SHX Text
PROVIDE ACCESS TO ALL DAMPERS INSTALLED
AutoCAD SHX Text
PANEL WHERE REQUIRED.
AutoCAD SHX Text
PROVIDE 24"x24" ACCESS
AutoCAD SHX Text
IN AN ACCESSIBLE LOCATION.
AutoCAD SHX Text
NOTE: DAMPER SHALL BE LOCATED
AutoCAD SHX Text
MAIN DUCT
AutoCAD SHX Text
L = 1/4 W, 4" MIN.
AutoCAD SHX Text
RIGID DUCT
AutoCAD SHX Text
CLOSE OPENING
AutoCAD SHX Text
AT CORNERS
AutoCAD SHX Text
DAMPER WITH LOCKING
AutoCAD SHX Text
BUTTERFLY VOLUME
AutoCAD SHX Text
QUADRANT
AutoCAD SHX Text
RIGID DUCT BRANCH CONNX.
AutoCAD SHX Text
OPENING (SIDES, TOP OR
AutoCAD SHX Text
MAIN DUCT
AutoCAD SHX Text
NOTE: DAMPER SHALL BE
AutoCAD SHX Text
OF TWO DUCT DIAMETERS
AutoCAD SHX Text
FROM MAIN DUCT
AutoCAD SHX Text
LOCATED A MINIMUM
AutoCAD SHX Text
AIR FLOW
AutoCAD SHX Text
ROUND DUCT BRANCH CONNX.
AutoCAD SHX Text
BOTTOM) CUT ACCURATELY
AutoCAD SHX Text
CONICAL OR BELL
AutoCAD SHX Text
ROUND DUCT
AutoCAD SHX Text
(SHAPE & SIZE)
AutoCAD SHX Text
MOUTH CONNECTION
AutoCAD SHX Text
DAMPER WITH LOCKING
AutoCAD SHX Text
BUTTERFLY VOLUME
AutoCAD SHX Text
QUADRANT
AutoCAD SHX Text
AIR FLOW
AutoCAD SHX Text
DUCT BRANCH DETAIL
AutoCAD SHX Text
CEILING EXHAUSTER
AutoCAD SHX Text
DIFFUSER SCHEDULE
AutoCAD SHX Text
WHITE W/OBD.
AutoCAD SHX Text
DUCT MOUNT ROTOLOUVER, ALUMINUM CONSTRUCTION, COLOR
AutoCAD SHX Text
CUBE CORE RETURN AIR GRILLE, ALL ALUMINUM CONTRUCTION,
AutoCAD SHX Text
NO.SPDS.
AutoCAD SHX Text
EXHAUST FAN SCHEDULE
AutoCAD SHX Text
EXHAUST FAN DETAIL
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
DUCTWORK (INSULATED)
AutoCAD SHX Text
DUCTWORK (UNINSULATED)
AutoCAD SHX Text
HOT WATER SUPPLY
AutoCAD SHX Text
HOT WATER RETURN
AutoCAD SHX Text
DUCTWORK ON ROOF
AutoCAD SHX Text
GAS LINE
AutoCAD SHX Text
COLD WATER
AutoCAD SHX Text
PIPE TO BE REMOVED
AutoCAD SHX Text
FIN-TUBE
AutoCAD SHX Text
FAN COIL UNIT
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
OUTSIDE AIR
AutoCAD SHX Text
FLEXIBLE DUCT
AutoCAD SHX Text
RADIANT CEILING PANEL
AutoCAD SHX Text
CHEMICAL FEEDER
AutoCAD SHX Text
AIR SEPARATOR
AutoCAD SHX Text
EVAPORATIVE COOLER
AutoCAD SHX Text
WATER HEATER
AutoCAD SHX Text
STORAGE TANK
AutoCAD SHX Text
MAKE-UP AIR UNIT
AutoCAD SHX Text
MECHANICAL EQUIPMENT BELOW ROOF
AutoCAD SHX Text
MECHANICAL EQUIPMENT ON ROOF
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
PARTIAL NO.
AutoCAD SHX Text
EXPANSION TANK
AutoCAD SHX Text
CONTROL SWITCH
AutoCAD SHX Text
NEW WORK INTERFACE
AutoCAD SHX Text
DIFFUSER
AutoCAD SHX Text
RELIEF HOOD
AutoCAD SHX Text
THERMOSTAT
AutoCAD SHX Text
WRAPPED AS SPECIFIED.
AutoCAD SHX Text
KEYED SYMBOL
AutoCAD SHX Text
CONDITIONS.
AutoCAD SHX Text
OTHERWISE NOTED.
AutoCAD SHX Text
3. ALL THERMOSTATS AND CONTROL SWITCHES SHALL BE LOCATED 4'-0" ABOVE FINISHED FLOOR UNLESS
AutoCAD SHX Text
5. ALL EXPOSED SUPPORTS AND HANGERS FOR EQUIPMENT OR PIPING SHALL BE PAINTED TO MATCH
AutoCAD SHX Text
4. SHEET METAL SADDLES SHALL BE PLACED UNDER PIPE INSULATION AT ALL HANGER LOCATIONS, WHERE
AutoCAD SHX Text
2. DUCT DIMENSIONS SHOWN ARE AIR PASSAGE DIMENSIONS. ALL INSULATED DUCT IS TO BE LINED OR
AutoCAD SHX Text
6. ALL INFORMATION TAKEN FROM OWNERS ORIGINAL DRAWINGS, CONTRACTOR TO FIELD VERIFY ACTUAL
AutoCAD SHX Text
ALL LOCATIONS AND COORDINATE WITH EXISTING FIELD CONDITIONS.
AutoCAD SHX Text
8. PRIOR TO INSTALLATION OF ANY DUCT, PIPE, OR EQUIPMENT, CONTRACTOR IS TO FIELD VERIFY
AutoCAD SHX Text
7. PROVIDE DIELECTRIC INSULATION ANYWHERE DISSIMILAR METALS CONTACT.
AutoCAD SHX Text
HANGERS CONTACT BARE COPPER PIPING PROVIDE DIELECTRIC INSULATION.
AutoCAD SHX Text
SURROUNDING ROOM OR STRUCTURE.
AutoCAD SHX Text
1. MECHANICAL CONTRACTORS ARE REQUIRED TO VISIT THE SITE PRIOR TO SUBMITTING A BID.
AutoCAD SHX Text
AIR HANDLER (HEAT PUMP) SCHEDULE
AutoCAD SHX Text
WT (LBS)
AutoCAD SHX Text
COOLING MBH
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
COOIL ENT. AIR
AutoCAD SHX Text
ADD. ELEC HEAT
AutoCAD SHX Text
CONDENSING UNIT SCHEDULE
AutoCAD SHX Text
TOTAL CAP.
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
AIR HANDLER UNIT
AutoCAD SHX Text
RETURN AIR DUCT
AutoCAD SHX Text
AUXILIARY
AutoCAD SHX Text
DRAIN PAN.
AutoCAD SHX Text
OUTSIDE AIR DUCT
AutoCAD SHX Text
SUPPLY AIR
AutoCAD SHX Text
FLEX CONNECTION (TYP.)
AutoCAD SHX Text
PROVIDE SENSOR TO
AutoCAD SHX Text
CONDENSATE DRAIN
AutoCAD SHX Text
W/ TRAP.
AutoCAD SHX Text
AUTOMATICALLY SHUT DOWN
AutoCAD SHX Text
VOLUME DAMPER
AutoCAD SHX Text
DRAIN CONDENSATE DRAIN FULL SIZE TO MOP SINK.
AutoCAD SHX Text
CONTRACTOR TO
AutoCAD SHX Text
RUN REFRIGERANT
AutoCAD SHX Text
LINES AS REQUIRED.
AutoCAD SHX Text
HEAT PUMP UNIJT DETAIL
AutoCAD SHX Text
4TWA4036A4000A
AutoCAD SHX Text
W/ HAIL GUARD
AutoCAD SHX Text
TEM4A0C36S41
AutoCAD SHX Text
SURFACE MOUNTED W/ OBD.
AutoCAD SHX Text
WHITE W/OBD. PROVIDE FRAME FOR GYP. CEILING INSTALL.
AutoCAD SHX Text
4-WAY SUPPLY DIFFUSER, ALUMINUM CONSTRUCTION, COLOR
AutoCAD SHX Text
W/120V. CONDENSATE PUMP. PROVIDE, BOTTOM FILTER ACCESS,
AutoCAD SHX Text
PROGRAMMABLE T-STAT, 600 CFM O.A.. DUCT SMOKE DETECTOR
AutoCAD SHX Text
W/ LINER.
AutoCAD SHX Text
9. DUCT INSULATION (WRAP) SHALL BE A MINIMUM OF 1.0 PCF DENSELY 2" THICK WITH A THERMAL
AutoCAD SHX Text
CONDUCTIVITY EQUAL TO 0.265 AT 75^ F. WRAP SHALL HAVE AN FSK FIBERGLASS REINFORCED FOIL
AutoCAD SHX Text
CONSTRUCTION STANDARDS WRITTEN BY S.M.A.C.N.A. AND THE MECHANICAL CODE.
AutoCAD SHX Text
RECOMMENDED CONSTRUCTION AS LISTED IN THE CURRENT EDITION OF HVAC METAL DUCT
AutoCAD SHX Text
11. ALL DUCTS SHALL BE CONSTRUCTED, SUPPORTED AND REINFORCED IN ACCORDANCE WITH THE
AutoCAD SHX Text
10. COORDINATE LOCATION OF GRILLES, REGISTERS, OR DIFFUSERS WITH ELECTRICAL CONTRACTOR.
AutoCAD SHX Text
12. FLEX DUCT MAXIMUM LENGHT TO BE FIVE FEET (5').
AutoCAD SHX Text
EXISTING DECK
AutoCAD SHX Text
NO PENETRATONS.
AutoCAD SHX Text
TWA120E4
AutoCAD SHX Text
TWA120E4
AutoCAD SHX Text
DUAL REFRIGERANT CIRCUIT W/ HAIL GUARD
AutoCAD SHX Text
W/120V. CONDENSATE PUMP. PROVIDE, BOTTOM FILTER ACCESS,
AutoCAD SHX Text
PROGRAMMABLE T-STAT, 1600 CFM O.A.. DUCT SMOKE DETECTOR
AutoCAD SHX Text
W/120V. CONDENSATE PUMP. PROVIDE, BOTTOM FILTER ACCESS,
AutoCAD SHX Text
PROGRAMMABLE T-STAT, 1600 CFM O.A.. DUCT SMOKE DETECTOR
AutoCAD SHX Text
DUAL REFRIGERANT CIRCUIT W/ HAIL GUARD
AutoCAD SHX Text
CEILING EXHAUSTER
AutoCAD SHX Text
CEILING EXHAUSTER
AutoCAD SHX Text
CEILING EXHAUSTER
AutoCAD SHX Text
ELF375DX
AutoCAD SHX Text
PROVIDE FLANGE.
AutoCAD SHX Text
FOUR INCH ALUMINUM OUTSIDE AIR LOUVER. W/ INSECT SCREEN.
AutoCAD SHX Text
SEE PLAN FOR SIZE TO MATCH DUCT.
AutoCAD SHX Text
ALUMINUM VENT CAP FOR EXTERIOR USE, PROVIDE WITH INSECT SCREEN
AutoCAD SHX Text
OUTLET DUCT
AutoCAD SHX Text
OMIT DUCT & EXHAUST TO
AutoCAD SHX Text
FLEXIBLE DUCT CONNECTION
AutoCAD SHX Text
PLENUM FOR ELECTRICAL ROOMS.
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
GRILLE SUPLIED WITH
AutoCAD SHX Text
MOUNTING FLANGES
AutoCAD SHX Text
ADJUSTABLE
AutoCAD SHX Text
TO BUILDING STRUCTURE
AutoCAD SHX Text
HANGER SUPPORT RODS
AutoCAD SHX Text
W/ VOLUME DAMPER
AutoCAD SHX Text
FOR RETURN AIR
AutoCAD SHX Text
CONDENSING UNIT
AutoCAD SHX Text
SOLENOID VALVE
AutoCAD SHX Text
SIGHT GLASS
AutoCAD SHX Text
SHUT-OFF VALVE
AutoCAD SHX Text
SHUT-OFF VALVE
AutoCAD SHX Text
SHUT-OFF VALVE
AutoCAD SHX Text
6In CONCRETE PAD 6in LARGER ALL
AutoCAD SHX Text
CONDUIT WIRING
AutoCAD SHX Text
AROUND THAN EQUIPMENT BASE.
AutoCAD SHX Text
SLAB ON GRADE
AutoCAD SHX Text
ANCHOR TO WALL
AutoCAD SHX Text
SEAL WATER TIGHT.
AutoCAD SHX Text
FIELD COORDINATE
AutoCAD SHX Text
PENETRATION ELEVATION
AutoCAD SHX Text
IN FIELD.
Page 2
SHEET:
REVISION:DATE:NO.
CONSTRUCTION
DOCUMENTS
EM
PL
OY
EE
F
IT
NE
SS
&
WE
LL
NE
SS
C
EN
TE
R
50
0 E
S
AN
A
NT
ON
IO
S
T.
EL
P
AS
O, T
EX
AS
20
16
-2
5 E
MP
LO
YE
E F
IT
NE
SS
&
W
EL
LN
ES
S C
EN
TE
R - C
ON
ST
RU
CT
IO
N D
OC
UM
EN
TS
DATE: SEPTEMBER 22 - 2018
M2.0
NEW
MECHANICAL
PLAN
AutoCAD SHX Text
COURTYARD
AutoCAD SHX Text
COURTYARD
AutoCAD SHX Text
MACHINES
AutoCAD SHX Text
FRONT DESK/
AutoCAD SHX Text
WOMEN'S LOCKER
AutoCAD SHX Text
MEN'S LOCKER
AutoCAD SHX Text
34/14 OVAL
AutoCAD SHX Text
34/18 OVAL
AutoCAD SHX Text
34/14 OVAL
AutoCAD SHX Text
34/18 OVAL
AutoCAD SHX Text
TYP. OF 8
AutoCAD SHX Text
TYP. OF 8
AutoCAD SHX Text
TYP. OF 2
AutoCAD SHX Text
REFRIGERANT LINES
AutoCAD SHX Text
IN CEILING SPACE
AutoCAD SHX Text
REFRIGERANT
AutoCAD SHX Text
LINES IN
AutoCAD SHX Text
CEILING SPACE
AutoCAD SHX Text
TYP. OF 2
AutoCAD SHX Text
TYP. OF 4
AutoCAD SHX Text
34/14 OVAL
AutoCAD SHX Text
ARCHITECTS
AutoCAD SHX Text
305 LEON ST.
AutoCAD SHX Text
(915) 533-2700 t..
AutoCAD SHX Text
(915) 533-2799 f..
AutoCAD SHX Text
EL PASO, TX 79901
AutoCAD SHX Text
carldanielarchitects.com
AutoCAD SHX Text
EL PASO, TEXAS 79928
AutoCAD SHX Text
12244 RATHMORE DR.
AutoCAD SHX Text
CONSULTING MECHANICAL ENGINEERS
AutoCAD SHX Text
OFFICE: (915) 856-9420
AutoCAD SHX Text
REGISTRATION NUMBER: F-1161
AutoCAD SHX Text
JOSE A. BERNAL
AutoCAD SHX Text
was authorized by JOSE A. BERNAL
AutoCAD SHX Text
P.E. 90861. on 20 .
AutoCAD SHX Text
The seal appearing on this document
AutoCAD SHX Text
NEW MECHANICAL PLAN
AutoCAD SHX Text
1/8" = 1'-0"
AutoCAD SHX Text
EXTEND EXHAUST DUCT THRU WALL AND PROVIDE VENT CAP AS SCHEDULED.
AutoCAD SHX Text
KEYED NOTES
AutoCAD SHX Text
EXTEND OUTSIDE AIR DUCT THRU ROOF AND PROVIDE WALL CAP OR LOUVER AS
AutoCAD SHX Text
FIELD COORDINATE EXACT PLACEMENT OF EXTERIOR EQUIPMENT WITH OWNER AND
AutoCAD SHX Text
ARCHITECT.
AutoCAD SHX Text
SCHEDULED
AutoCAD SHX Text
PROVIDE WITH INSECT SCREEN.
Page 3
SHEET:
REVISION:DATE:NO.
CONSTRUCTION
DOCUMENTS
EM
PL
OY
EE
F
IT
NE
SS
&
WE
LL
NE
SS
C
EN
TE
R
50
0 E
S
AN
A
NT
ON
IO
S
T.
EL
P
AS
O, T
EX
AS
20
16
-2
5 E
MP
LO
YE
E F
IT
NE
SS
&
W
EL
LN
ES
S C
EN
TE
R - C
ON
ST
RU
CT
IO
N D
OC
UM
EN
TS
DATE: SEPTEMBER 22 - 2018
P1.0
LEGEND, NOTES,
SCHEDULES
AND DETAILS
AutoCAD SHX Text
ARCHITECTS
AutoCAD SHX Text
305 LEON ST.
AutoCAD SHX Text
(915) 533-2700 t..
AutoCAD SHX Text
(915) 533-2799 f..
AutoCAD SHX Text
EL PASO, TX 79901
AutoCAD SHX Text
carldanielarchitects.com
AutoCAD SHX Text
EL PASO, TEXAS 79928
AutoCAD SHX Text
12244 RATHMORE DR.
AutoCAD SHX Text
CONSULTING MECHANICAL ENGINEERS
AutoCAD SHX Text
OFFICE: (915) 856-9420
AutoCAD SHX Text
REGISTRATION NUMBER: F-1161
AutoCAD SHX Text
JOSE A. BERNAL
AutoCAD SHX Text
was authorized by JOSE A. BERNAL
AutoCAD SHX Text
P.E. 90861. on 20 .
AutoCAD SHX Text
The seal appearing on this document
AutoCAD SHX Text
LAVATORY (HANDICAPPED)
AutoCAD SHX Text
WALL CLEANOUT
AutoCAD SHX Text
VENT THRU ROOF
AutoCAD SHX Text
NEW WORK INTERFACE
AutoCAD SHX Text
KEYED SYMBOL
AutoCAD SHX Text
WATER HEATER
AutoCAD SHX Text
PARTIAL NO.
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
ELECTRIC WATER COOLER (HANDICAPPED)
AutoCAD SHX Text
WATER CLOSET (HANDICAPPED)
AutoCAD SHX Text
MOP SERVICE BASIN
AutoCAD SHX Text
VENT LINE
AutoCAD SHX Text
HOT WATER LINE
AutoCAD SHX Text
COLD WATER LINE
AutoCAD SHX Text
SEWER (BURIED)
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
3. ALL PLUMBING FIXTURES SHALL MEET AND BE INSTALLED AT DIMENSIONS
AutoCAD SHX Text
REQUIRED BY TEXAS ACCESSIBILITY STANDARDS FOR HANDICAPPED
AutoCAD SHX Text
4. ALL SEWER VENTS THRU ROOF (VTR) SHALL BE NO CLOSER THAN 5 FT.
AutoCAD SHX Text
TO EDGE OF ROOF AND A MINIMUM OF 10 FT. FROM ANY AIR INTAKE.
AutoCAD SHX Text
PERSONS.
AutoCAD SHX Text
1. CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF ALL EXISTING AND
AutoCAD SHX Text
PROPOSED UTILITIES, AND SITE CONDITIONS PRIOR TO BEGINNING WORK.
AutoCAD SHX Text
2. PROVIDE DIELECTRIC INSULATION FOR COPPER PIPE ANYWHERE IT
AutoCAD SHX Text
CONTACTS DISSIMILAR METAL. THIS INCLUDES THE WATER HEATER
AutoCAD SHX Text
CONNECTIONS.
AutoCAD SHX Text
5. ALL SEWER, WASTE, AND VENT PIPING SHALL BE SCHEDULE 40 PVC.
AutoCAD SHX Text
6. DOMESTIC HOT AND COLD WATER LINES SHALL BE TYPE "L" COPPER
AutoCAD SHX Text
7. INSULATE ALL HOT WATER LINES AND EXTERIOR WATER LINES WITH TWO
AutoCAD SHX Text
INCH FIBERGLASS ASJ INSULATION. PROVIDE ALUMINUM JACKETING ON
AutoCAD SHX Text
CONDENSATE OR DRAIN LINE
AutoCAD SHX Text
CD or DL
AutoCAD SHX Text
MAKE-UP WATER LINE
AutoCAD SHX Text
EXTERIOR.
AutoCAD SHX Text
8. ANY PLASTIC PIPING LOCATED IN PLENUM RETURN SPACE SHALL BE
AutoCAD SHX Text
WRAPPED WITH 3M FIREMASTER BLANKET.
AutoCAD SHX Text
PRESSURE REGULATOR
AutoCAD SHX Text
LINT TRAP
AutoCAD SHX Text
PLUMBING GENERAL NOTES
AutoCAD SHX Text
1- #4 REBAR
AutoCAD SHX Text
NOTE: CLEANOUT MAY
AutoCAD SHX Text
BE PLACED IN SIDEWALKS
AutoCAD SHX Text
DOUBLE CLEANOUT WHERE
AutoCAD SHX Text
INDICATED
AutoCAD SHX Text
ROUND CAST IRON TOP
AutoCAD SHX Text
ASPHALT OR CONCRETE
AutoCAD SHX Text
SLOTTED CLEANOUT PLUG
AutoCAD SHX Text
ZURN Z-1400 CLEANOUT OR
AutoCAD SHX Text
APPROVED EQUAL
AutoCAD SHX Text
NO HUB OR CONNECTION
AutoCAD SHX Text
LENGTH AS REQUIRED
AutoCAD SHX Text
TOP 1/2"
AutoCAD SHX Text
CLEANOUT DETAIL
AutoCAD SHX Text
RECOVERY
AutoCAD SHX Text
GPH@ 100%%D T
AutoCAD SHX Text
CAPACITY
AutoCAD SHX Text
WATER HEATER SCHEDULE
AutoCAD SHX Text
460V/ 3PH W/ EXPANSION TANK.
AutoCAD SHX Text
AO SMITH
AutoCAD SHX Text
DSE-40-12
AutoCAD SHX Text
WATER HEATER CONNECTION DETAIL
AutoCAD SHX Text
ASME TEMPERATURE AND PRESSURE
AutoCAD SHX Text
RELIEF VALVE WITH DRAIN FULL
AutoCAD SHX Text
SIZE TO FLOOR SINK.
AutoCAD SHX Text
BALL VALVE TYP.
AutoCAD SHX Text
CHECK VALVE
AutoCAD SHX Text
EXPANSION TANK
AutoCAD SHX Text
VACUUM RELIEF
AutoCAD SHX Text
ELEVATED BASE
AutoCAD SHX Text
TO FLOOR SINK
AutoCAD SHX Text
MOP SINK
AutoCAD SHX Text
DRAIN PAN
AutoCAD SHX Text
9. DRAWINGS ARE DIAGRAMMATIC DO NOT SCALE DRAWINGS FOR INSTALLATION
AutoCAD SHX Text
OF EQUIPMENT. COORDINATE WITH ARCHITECTURAL DRAWINGS.
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
SHOKTROL
AutoCAD SHX Text
ACCESSORIES
AutoCAD SHX Text
PLUMBING FIXTURE SCHEDULE
AutoCAD SHX Text
C. I. BODY, 7"~, TYPE "B" STRAINER W/ ATP.
AutoCAD SHX Text
INSTALL ON ALL FLOOR DRAINS, AND FLOOR SINKS. INSTALL BEHIND ACCESS DOOR.
AutoCAD SHX Text
WOODFORD
AutoCAD SHX Text
INSTALL BEHIND ACCESS DOOR.
AutoCAD SHX Text
DRAIN, ZURN Z-8802-LK STOPS, HANDY-SHIELD INSULATION COVERS,
AutoCAD SHX Text
ZURN Z-81101 FAUCET, McGUIRE 8089 CAST BRASS P-TRAP, Z-8746 OFFSET GRID
AutoCAD SHX Text
PROVIDE WIT ATP.
AutoCAD SHX Text
W/ 830-AA FAUCET, 832-AA HOSE AND BRACKET, 889 MOP HANGER.
AutoCAD SHX Text
TSBC-6010
AutoCAD SHX Text
PROVIDE BRADLEY S59-400 THERMOSTATIC MIXING VALVE, ASSE 1070.
AutoCAD SHX Text
HALSEY TAYLOR
AutoCAD SHX Text
HTHB-HAC8BLPV-WF
AutoCAD SHX Text
8.0 GPH OF 50^F WATER @ 90^F AMBIENT, McGUIRE 155A DRAIN, DEARBORN BRASS 751
AutoCAD SHX Text
P-TRAP, McGUIRE 2165 ANGLE STOPS, ZURN Z-1225 CARRIER, 120V. WITH BOTTLE FILLER.
AutoCAD SHX Text
SEE ARCHITECTS DRAWINGS F0R MOUNTING HEIGHT.
AutoCAD SHX Text
BELL & GOSSETT
AutoCAD SHX Text
SERIES-100
AutoCAD SHX Text
5 GPM, 10 FT HD, ALL BRONZE CONSTRUCTION, 1/12 HP, 120V, 1 PHASE, W/ TEMP. SWITCH.
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
1-117-FS
AutoCAD SHX Text
MOUNT CONTROL VALVE AS SHOWN IN ARCH DWGS. PROVIDE 1.O GPM SHOWER HEAD.
AutoCAD SHX Text
PRESSURE BALANCING MIXING VALVE, WALL/HAND SHOWER W/FLEXIBLE METAL HOSE, IN LINE
AutoCAD SHX Text
VACUUM BREAKER, WALL CONNECTION AND FLANGE. 30" SLIDE BAR AND DIVERTER VALVE.
AutoCAD SHX Text
Z-5665-BWL
AutoCAD SHX Text
W/ ZURN Z-6000AV-HET FLUSH VALVE, ZURN MODEL Z5955SS SEAT (WHITE), 1.1 GPF.
AutoCAD SHX Text
W/ ZURN Z-6000AV-HET FLUSH VALVE, ZURN MODEL Z5955SS SEAT (WHITE), 1.28 GPF.
AutoCAD SHX Text
Z-5655-BWL
AutoCAD SHX Text
C. I. BODY, 10"~SQUARE TOP PROM-DECK DRAIN.
AutoCAD SHX Text
W/ 3/4 GRATE AND ATP.
Page 4
SHEET:
REVISION:DATE:NO.
CONSTRUCTION
DOCUMENTS
EM
PL
OY
EE
F
IT
NE
SS
&
WE
LL
NE
SS
C
EN
TE
R
50
0 E
S
AN
A
NT
ON
IO
S
T.
EL
P
AS
O, T
EX
AS
20
16
-2
5 E
MP
LO
YE
E F
IT
NE
SS
&
W
EL
LN
ES
S C
EN
TE
R - C
ON
ST
RU
CT
IO
N D
OC
UM
EN
TS
DATE: SEPTEMBER 22 - 2018
P2.0
NEW
PLUMBING
PLAN
AutoCAD SHX Text
COURTYARD
AutoCAD SHX Text
COURTYARD
AutoCAD SHX Text
MACHINES
AutoCAD SHX Text
FRONT DESK/
AutoCAD SHX Text
WOMEN'S LOCKER
AutoCAD SHX Text
MEN'S LOCKER
AutoCAD SHX Text
4" UNDERGROUND
AutoCAD SHX Text
ARCHITECTS
AutoCAD SHX Text
305 LEON ST.
AutoCAD SHX Text
(915) 533-2700 t..
AutoCAD SHX Text
(915) 533-2799 f..
AutoCAD SHX Text
EL PASO, TX 79901
AutoCAD SHX Text
carldanielarchitects.com
AutoCAD SHX Text
EL PASO, TEXAS 79928
AutoCAD SHX Text
12244 RATHMORE DR.
AutoCAD SHX Text
CONSULTING MECHANICAL ENGINEERS
AutoCAD SHX Text
OFFICE: (915) 856-9420
AutoCAD SHX Text
REGISTRATION NUMBER: F-1161
AutoCAD SHX Text
JOSE A. BERNAL
AutoCAD SHX Text
was authorized by JOSE A. BERNAL
AutoCAD SHX Text
P.E. 90861. on 20 .
AutoCAD SHX Text
The seal appearing on this document
AutoCAD SHX Text
NEW PLUMBING PLAN
AutoCAD SHX Text
1/8" = 1'-0"
AutoCAD SHX Text
SAW CUT CONCRETE SLAB AND EXTEND NEW WASTE LINE TO EXISTING. FIELD VERIFY WITH OWNER EXACT
AutoCAD SHX Text
KEYED NOTES
AutoCAD SHX Text
EXTEND DOMESTIC COLD WATER LINE FROM EXISTING WATER LINE. FIELD VERIFY WITH OWNER EXACT
AutoCAD SHX Text
EXTEND CONDENSATE DRAINS FROM ALL NEW UNITS TO FLOOR SINK.
AutoCAD SHX Text
CONNECTION POINT.
AutoCAD SHX Text
CONNECTION POINT. PATCH AND REPAIR SLAB TO MATCH EXISTING.
AutoCAD SHX Text
INSTALL TWO NEW FLOOR DRAINS TO DRAIN DECK ABOVE. EXTEND LEADERS DOWN FURROUT AND
AutoCAD SHX Text
UNDERGROUND TO EXISTING STORM WATER LIFT STATION. COORDINATE EXACT LOCATION OF DRAINS
AutoCAD SHX Text
EXTEND VENT TO EXISTING BUILDING VENT SYSTEM PIPING. FIELD VERIFY EXACT LOCATION.
AutoCAD SHX Text
WITH ARCHITECTURAL DRAWING A1.2
AutoCAD SHX Text
3. SYSTEM SHALL BE INTERFACED WITH BUILDING FIRE AND SMOKE ALARM.
AutoCAD SHX Text
FIRE PROTECTION NOTES
AutoCAD SHX Text
1. NEW BUILDING ADDITION SHALL HAVE A NFPA APPROVED FIRE SPRINKLER
AutoCAD SHX Text
2. FIRE SPRINKLER HEADS SHALL BE LOCATED IN SYMMETRICAL PATTERN
AutoCAD SHX Text
RELATED TO CEILING FEATURES SUCH AS GRID BEAMS, LIGHT FIXTURES,
AutoCAD SHX Text
DIFFUSERS, ETC. AND WHERE APPLICABLE HEADS SHALL BE LOCATED
AutoCAD SHX Text
SYMMETRICALLY WITH THE CEILING GRID, CENTERED IN TWO DIRECTIONS.
AutoCAD SHX Text
SYSTEM. EXTEND FROM EXISTING BUILDING SYSTEM.
Page 5
SHEET:
REVISION:DATE:NO.
CONSTRUCTION
DOCUMENTS
EM
PL
OY
EE
F
IT
NE
SS
&
WE
LL
NE
SS
C
EN
TE
R
50
0 E
S
AN
A
NT
ON
IO
S
T.
EL
P
AS
O, T
EX
AS
20
16
-2
5 E
MP
LO
YE
E F
IT
NE
SS
&
W
EL
LN
ES
S C
EN
TE
R - C
ON
ST
RU
CT
IO
N D
OC
UM
EN
TS
DATE: SEPTEMBER 22 - 2018
P3.0
ENLARGED PLUMBING
WASTE &
WATER RISER
AutoCAD SHX Text
WOMEN'S LOCKER
AutoCAD SHX Text
WOMEN'S LOCKER
AutoCAD SHX Text
MEN'S LOCKER
AutoCAD SHX Text
CONNECT TO
AutoCAD SHX Text
EXISTING STACK
AutoCAD SHX Text
SHUT-OFF
AutoCAD SHX Text
SHUT-OFF
AutoCAD SHX Text
SHUT-OFF
AutoCAD SHX Text
VALVE (TYP.)
AutoCAD SHX Text
SHUT-OFF
AutoCAD SHX Text
SHUT-OFF
AutoCAD SHX Text
SHUT-OFF
AutoCAD SHX Text
SHUT-OFF
AutoCAD SHX Text
SHUT-OFF
AutoCAD SHX Text
SHUT-OFF
AutoCAD SHX Text
ARCHITECTS
AutoCAD SHX Text
305 LEON ST.
AutoCAD SHX Text
(915) 533-2700 t..
AutoCAD SHX Text
(915) 533-2799 f..
AutoCAD SHX Text
EL PASO, TX 79901
AutoCAD SHX Text
carldanielarchitects.com
AutoCAD SHX Text
EL PASO, TEXAS 79928
AutoCAD SHX Text
12244 RATHMORE DR.
AutoCAD SHX Text
CONSULTING MECHANICAL ENGINEERS
AutoCAD SHX Text
OFFICE: (915) 856-9420
AutoCAD SHX Text
REGISTRATION NUMBER: F-1161
AutoCAD SHX Text
JOSE A. BERNAL
AutoCAD SHX Text
was authorized by JOSE A. BERNAL
AutoCAD SHX Text
P.E. 90861. on 20 .
AutoCAD SHX Text
The seal appearing on this document
AutoCAD SHX Text
ENLARGED PLUMBING PLAN
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
WASTE & WATER RISER
AutoCAD SHX Text
ENLARGED PLUMBING PLAN
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
WASTE & WATER RISER