52
Use: Compression type connectors are used to secure and terminate steel EMT conduit to knock-outs in concrete-tight box, dry or damp location applications. • Concrete-Tight S›kmal› Zamak Rakor : EMT borular› buat, armatür, pano ve benzeri yerlerde sonland›rmakta kullan›l›r. Materials: • Zinc Die-Cast Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348 EMT Compression Connectors/Die Cast EMT Compression Couplings/Die Cast Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt. Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt. Boxed 8130 08013-8 1/2" 1.70 0.98 0.73 - 50/500 60 8131 08131-5 3/4" 1.78 1.22 0.94 - 25/250 48 8132 08132-2 1" 1.81 1.52 1.18 - 10/100 28 8133 08133-9 1 1/4" 2.12 1.84 1.52 - 10/40 17.6 8134 08134-6 1 1/2" 2.42 2.14 1.76 - 10/40 28.2 8135 08135-8 2" 2.47 2.58 2.23 - 5/20 18.1 8136* 08136-5 2 1/2" 3.27 3.28 2.90 - 12 16 8137* 08137-2 3" 3.35 3.94 3.53 - 12 21 8138* 08138-9 3 1/2" 3.50 4.50 4.00 - 10 22 8139* 08139-6 4" 3.65 4.98 4.50 - 6 15 * EMT, IMC & RIGID Boxed / Raintight 8130-RT 08170-4 1/2" 1.19 0.98 0.38 - 50/500 35 8131-RT 08171-6 3/4" 1.29 1.22 0.40 - 25/250 25 8132-RT 08172-8 1" 1.48 1.52 0.55 - 50/200 28 Use: Compression type couplings are used to join lengths of steel EMT conduit for concrete-tight, dry or damp location applications. • Concrete-Tight S›kmal› Zamak Muf: EMT borular›n birbirine eklenmesinde kullan›l›r. Materials: • Zinc Die-Cast Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348 ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925 Certification: www.afielektrik.com B 01 CONDUIT FITTINGS Emt Fittings/EMT Boru Aksesuarlar› Boxed 8140 08140-2 1/2" 1.19 0.98 0.38 - 50/500 50 8141 08141-4 3/4" 1.29 1.22 0.40 - 25/250 35 8142 08142-1 1" 1.48 1.52 0.55 - 50/200 40 8143 08143-8 1 1/4" 1.70 1.84 0.61 - 25/100 40 8144 08144-5 1 1/2" 1.86 2.14 0.61 - 10/40 22 8145 08145-2 2" 2.13 2.54 0.76 - 5/20 16 8146* 08146-9 2 1/2" 2.62 3.28 1.01 - 12 13 8147* 08147-6 3" 2.70 3.94 1.04 - 12 16 8148* 08148-3 3 1/2" 2.80 4.50 1.08 - 10 18 8149* 08149-0 4" 2.80 4.98 1.08 - 6 12 *EMT, IMC & RIGID Boxed w/Insulated Throat 8150 08150-6 1/2" 1.19 0.98 0.38 - 50/500 50 8151 08151-3 3/4" 1.29 1.22 0.40 - 25/250 35 8152 08152-0 1" 1.48 1.52 0.55 - 50/200 40 8153 08153-7 1 1/4" 1.70 1.84 0.61 - 25/100 40 8154 08154-4 1 1/2" 1.86 2.14 0.61 - 10/40 22 8155 08155-1 2" 2.13 2.58 0.76 - 5/20 16 8156* 08156-8 2 1/2" 2.62 3.28 1.01 - 12 13 8157* 08157-5 3" 2.70 3.94 1.04 - 12 16 8158* 08158-2 3 1/2" 2.80 4.50 1.08 - 10 18 8159* 08159-9 4" 2.80 4.98 1.08 - 6 12 * EMT, IMC & RIGID Boxed / Raintight 8150-RT 08173-5 1/2" 1.19 0.98 0.38 - 50/500 60 8151-RT 08174-2 3/4" 1.29 1.22 0.40 - 25/250 43 8152-RT 08175-9 1" 1.48 1.52 0.55 - 10/100 25

EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

  • Upload
    others

  • View
    14

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

Use:Compression type connectors are used to secureand terminate steel EMT conduit to knock-outs inconcrete-tight box, dry or damp locationapplications.• Concrete-Tight

S›kmal› Zamak Rakor :EMT borular› buat, armatür,pano ve benzeri yerlerdesonland›rmakta kullan›l›r.

Materials:• Zinc Die-Cast

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

EMT Compression Connectors/Die Cast

EMT Compression Couplings/Die Cast

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8130 08013-8 1/2" 1.70 0.98 0.73 - 50/500 608131 08131-5 3/4" 1.78 1.22 0.94 - 25/250 488132 08132-2 1" 1.81 1.52 1.18 - 10/100 288133 08133-9 1 1/4" 2.12 1.84 1.52 - 10/40 17.68134 08134-6 1 1/2" 2.42 2.14 1.76 - 10/40 28.28135 08135-8 2" 2.47 2.58 2.23 - 5/20 18.18136* 08136-5 2 1/2" 3.27 3.28 2.90 - 12 168137* 08137-2 3" 3.35 3.94 3.53 - 12 218138* 08138-9 3 1/2" 3.50 4.50 4.00 - 10 228139* 08139-6 4" 3.65 4.98 4.50 - 6 15* EMT, IMC & RIGID

Boxed / Raintight8130-RT 08170-4 1/2" 1.19 0.98 0.38 - 50/500 358131-RT 08171-6 3/4" 1.29 1.22 0.40 - 25/250 258132-RT 08172-8 1" 1.48 1.52 0.55 - 50/200 28

Use:Compression type couplings are used to joinlengths of steel EMT conduit for concrete-tight, dryor damp location applications.• Concrete-Tight

S›kmal› Zamak Muf:EMT borular›n birbirineeklenmesinde kullan›l›r.

Materials:• Zinc Die-Cast

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

ELECTRICAL PRODUCTS

UL Listed: E210498CSA Certified:LR57925

Certification:

UL Listed: E210498CSA Certified:LR57925

Certification:

www.afielektrik.comB 01

CONDUIT FITTINGSEmt Fittings/EMT Boru Aksesuarlar›

Boxed8140 08140-2 1/2" 1.19 0.98 0.38 - 50/500 508141 08141-4 3/4" 1.29 1.22 0.40 - 25/250 358142 08142-1 1" 1.48 1.52 0.55 - 50/200 408143 08143-8 1 1/4" 1.70 1.84 0.61 - 25/100 408144 08144-5 1 1/2" 1.86 2.14 0.61 - 10/40 228145 08145-2 2" 2.13 2.54 0.76 - 5/20 168146* 08146-9 2 1/2" 2.62 3.28 1.01 - 12 138147* 08147-6 3" 2.70 3.94 1.04 - 12 168148* 08148-3 3 1/2" 2.80 4.50 1.08 - 10 188149* 08149-0 4" 2.80 4.98 1.08 - 6 12*EMT, IMC & RIGID

Boxed w/Insulated Throat8150 08150-6 1/2" 1.19 0.98 0.38 - 50/500 508151 08151-3 3/4" 1.29 1.22 0.40 - 25/250 358152 08152-0 1" 1.48 1.52 0.55 - 50/200 408153 08153-7 1 1/4" 1.70 1.84 0.61 - 25/100 408154 08154-4 1 1/2" 1.86 2.14 0.61 - 10/40 228155 08155-1 2" 2.13 2.58 0.76 - 5/20 168156* 08156-8 2 1/2" 2.62 3.28 1.01 - 12 138157* 08157-5 3" 2.70 3.94 1.04 - 12 168158* 08158-2 3 1/2" 2.80 4.50 1.08 - 10 188159* 08159-9 4" 2.80 4.98 1.08 - 6 12* EMT, IMC & RIGID

Boxed / Raintight8150-RT 08173-5 1/2" 1.19 0.98 0.38 - 50/500 608151-RT 08174-2 3/4" 1.29 1.22 0.40 - 25/250 438152-RT 08175-9 1" 1.48 1.52 0.55 - 10/100 25

Page 2: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

Use:Set screw type couplings are used to join lengthsof steel EMT conduit for concrete-tight or drylocation applications.• Concrete-Tight when taped• 1 1-4"-4" Double Set Screw

Vidal› Zamak Muf:EMT borular› birbirineba¤lamakta kullan›l›r.

Materials:• Zinc Die-Cast

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

Use:Set screw type connectors are used to secure andterminate steel EMT conduit to knock-outs inconcrete-tight box or dry location applications.• Concrete-Tight when taped• 1 1-4"-4" Double Set Screw

Vidal› Zamak Rakor:EMT borular› buat, armatür,pano ve benzeri yerlerdesonland›rmakta kullan›l›r.

Materials:• Zinc Die-Cast

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

EMT Set Screw Couplings/Die Cast

EMT Set Screw Connectors/Die Cast

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8100 08100-1 1/2" 1.14 0.38 0.72 - 50/500 358101 08101-8 3/4" 1.40 0.46 0.94 - 25/250 258102 08102-5 1" 1.55 1.00 1.18 - 50/200 308103 08103-2 1 1/4" 1.96 0.62 1.53 - 25/100 328104 08104-9 1 1/2" 2.20 0.70 1.77 - 10/40 168105 08105-6 2" 2.50 0.75 2.23 - 5/20 118106* 70205-0 2 1/2" 3.00 1.00 2.89 - 12 108107* 70210-4 3" 3.38 3.93 3.54 - 12 128108* 08108-7 3 1/2" 3.56 4.45 4.06 - 10 138109* 70220-3 4" 3.75 1.02 4.53 - 6 9*EMT, IMC & RIGID

Boxed w/ Insulated Throat8110 08110-0 1/2" 1.14 0.38 0.72 - 50/500 358111 08111-7 3/4" 1.40 0.46 0.94 - 25/250 258112 08112-4 1" 1.55 1.00 1.18 - 50/200 308113 08113-1 1 1/4" 1.96 0.62 1.53 - 25/100 328114 08114-8 1 1/2" 2.20 0.70 1.77 - 10/40 168115 08115-5 2" 2.50 0.75 2.23 - 5/20 118116* 08116-2 2 1/2" 3.00 1.00 2.89 - 12 108117* 08117-9 3" 3.38 3.93 3.54 - 12 128118* 08118-6 3 1/2" 3.56 4.45 4.06 - 10 138119* 08119-3 4" 3.75 1.02 4.53 - 6 9*EMT, IMC & RIGID

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8120 08120-9 1/2" 1.50 0.93 0.73 - 50/500 358121 08121-6 3/4" 1.87 1.14 0.95 - 25/250 258122 08122-3 1" 2.00 1.41 1.19 - 50/200 288123 08123-0 1 1/4" 2.50 1.83 1.53 - 25/100 328124 08124-7 1-1/2" 2.87 2.06 1.77 - 10/40 248125 08125-4 2" 3.44 2.53 2.23 - 5/20 118126* 70305-7 2-1/2" 4.00 3.30 2.90 - 12 98127* 70310-1 3" 4.49 3.94 3.54 - 12 128128* 08128-5 3 1/2" 4.92 4.45 4.05 - 10 128129* 70320-0 4" 5.23 4.96 4.55 - 6 10*EMT, IMC & RIGID

ELECTRICAL PRODUCTS

UL Listed: E210498CSA Certified:LR57925

Certification:

UL Listed: E210498CSA Certified:LR57925

Certification:

B 02

www.afielektrik.com

CONDUIT FITTINGSEmt Fittings/EMT Boru Aksesuarlar›

Page 3: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

Use:Compression type couplings are used to joinlengths of steel EMT conduit for concrete-tight, dryor damp location applications.• Concrete-Tight

S›kmal› Çelik Muf:EMT borular› birbirineba¤lamakta kullan›l›r.

Materials:• Steel

Certification:

E210498 LR57925E155411E184480

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

EMT Compression Connectors/Steel

EMT Compression Couplings/Steel

Use:Compression type connectors are used to secureand terminate steel EMT conduit to knock-outs inconcrete-tight box, dry or damp locationapplications.• Concrete-Tight

S›kmal› Çelik Rakor:EMT borular› buat, armatür, panove benzeri yerlerde sonland›rmaktakullan›l›r.

Materials:• Steel

Certification:

E210498 LR57925E155411E184480

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

ELECTRICAL PRODUCTS

Catalog UPC No Trade Case CaseNumber 0-87115 Size Qty Wt.

3021191031013131318

09140-609141-309142-009143-709144-409145-109146-809147-509148-209149-9

1/2"3/4"1"1-1/4"1-1/2"2"2-1/2"3"3-1/2"4"

50/25025/12515/75205108555

Boxed9140914191429143914491459146*9147*9148*9149** EMT & RIGID

Catalog UPC No Trade Case CaseNumber 0-87115 Size Qty Wt.

3021191031013131318

09150-509151-209152-909153-609154-309155-009156-709157-409158-109159-8

1/2"3/4"1"1-1/4"1-1/2"2"2-1/2"3"3-1/2"4"

50/25025/12515/75205108555

Boxed w/Insulated Throat9150915191529153915491559156*9157*9158*9159** EMT & RIGID

Catalog UPC No Trade Case CaseNumber 0-87115 Size Qty Wt.

3220231241219161825

09130-709131-409132-109133-809134-509135-209136-909137-609138-309139-0

1/2"3/4"1"1-1/4"1-1/2"2"2-1/2"3"3-1/2"4"

50/25025/12515/75205108555

Boxed9130913191329133913491359136*9137*9138*9139** EMT & RIGID

www.afielektrik.comB 03

CONDUIT FITTINGSEmt Fittings/EMT Boru Aksesuarlar›

Page 4: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

Use:Set screw type couplings are used to join lengthsof steel EMT conduit for concrete-tight or drylocation applications.• Concrete-Tight when taped• 1 1-4"-4" Double Set Screw

Vidal› Çelik Ek Muf :EMT borular›eklemekte kullan›l›r.

Materials:• Steel

Certification:

E210498 LR57925E155411E184480

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

EMT Set Screw Connectors/Steel

EMT Set Screw Couplings/Steel

Use:Set screw type connectors are used to secure andterminate steel EMT conduit to knock-outs inconcrete-tight box or dry location applications.• Concrete-Tight when taped• 1 1-4"-4" Double Set Screw

Vidal› Çelik Rakor :EMT borular› buat, armatür, panove benzeri yerlerde sonland›rmaktakullan›l›r.

Materials:• Steel

Certification:

E210498 LR57925E155411E184480

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

ELECTRICAL PRODUCTS

Catalog UPC No Trade Case CaseNumber 0-87115 Size Qty Wt.

25142310681191314

09100-009101-709102-409103-109104-809105-509106-209107-509108-609109-3

1/2"3/4"1"1-1/4"1-1/2"2"2-1/2"3"3-1/2"4"

50/25025/12520/1005/2510108555

Boxed9100910191029103910491059106*9107*9108*9109**EMT & RIGID

Catalog UPC No Trade Case CaseNumber 0-87115 Size Qty Wt.

25142310681191314

09110-909111-609112-309113-009114-709115-409116-109117-809118-509119-2

1/2"3/4"1"1-1/4"1-1/2"2"2-1/2"3"3-1/2"4"

50/25025/12520/1005/2510108555

Boxed w/Insulated Throat9110911191129113911491159116*9117*9118*9119**EMT & RIGID

Catalog UPC No Trade Case CaseNumber 0-87115 Size Qty Wt.

251824114913111314

09120-809121-509122-209123-909124-609125-309126-009127-709128-409129-1

1/2"3/4"1"1-1/4"1-1/2"2"2-1/2"3"3-1/2"4"

50/25025/12510/1005/2510108555

Boxed9120912191229123912491259126*9127*9128*9129** EMT & RIGID

B 04

www.afielektrik.com

CONDUIT FITTINGSEmt Fittings/EMT Boru Aksesuarlar›

Page 5: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

Use:Compression type couplings are used to joinlengths of steel EMT conduit for raintight applications• Raintight

S›kmal› Çelik Muf (S›v› S›zd›rmaz) :EMT borular› birbirine eklemektekullan›l›r.

Raintight Steel Compression Connectors

RaintightSteel Compression Couplings

Use:Compression type connectors are used to secureand terminate steel EMT conduit to knock-outs inraintight applications.• Raintight

S›kmal› Çelik Rakor (S›v› S›zd›rmaz) :EMT borular› buat, armatür, panove benzeri yerlerde sonland›rmaktakullan›l›r.

Materials:• Steel

Certification:

E200730

Standards:UL 514BNEMA FB-1

Catalog UPC No Trade Case CaseNumber 0-87115 Size Qty Wt.

09600-509601-209602-909603-609604-309605-009606-709607-409608-109609-8

1/2"3/4"1"1-1/4"1-1/2"2"2-1/2"3"3-1/2"4"

25/25025/25010/10025201512653

Boxed9600960196029603960496059606960796089609

26.542.522.710.2101021.214.114.410.3

Materials:• Steel

Certification:

E200730

Standards:UL 514BNEMA FB-1

CatalogNumber

90° boru dönüfllerinde kullan›l›r 45º ve 30º

1/2 16 4 102 61/4 159 11/2 38

3/4 21 4 1/2 114 71/16 189 11/2 38

1 27 5 3/4 146 91/4 235 17/8 48

11/4 35 7 1/4 184 101/2 267 2 51

11/2 41 8 1/4 210 125/8 321 2 51

2 53 9 1/2 241 141/4 368 2 51

21/2 63 10 1/2 267 187/8 479 3 76

3 78 13 330 20 508 31/8 79

31/2 91 15 381 233/4 603 31/4 83

4 103 16 406 267/8 983 33/8 86

TradeSize

TradeDesignator

MinimumUL Radius

Figure 1.Offset

Figuro 2.straight End

in. mmin. mm in. mmin. mm

EMT-ELL050EMT-ELL075EMT-ELL100EMT-ELL125EMT-ELL150EMT-ELL200EMT-ELL250EMT-ELL300EMT-ELL350EMT-ELL400

ELECTRICAL PRODUCTS

UL Listed:CSA Certified:

Certification:

www.afielektrik.comB 05

Catalog UPC No Trade Case CaseNumber 0-87115 Size Qty Wt.

26.542.522.710.2101021.214.114.410.3

09610-409611-109612-809613-509614-209615-909616-609617-309618-009619-7

1/2"3/4"1"1-1/4"1-1/2"2"2-1/2"3"3-1/2"4"

25/25025/25010/10025201512653

Boxed w/Insulated Throat9610961196129613961496159616961796189619

Catalog UPC No Trade Case CaseNumber 0-87115 Size Qty Wt.

3553.32812.111.911.824.715.815.511.8

09620-309621-009622-709623-409624-109625-809626-509627-209628-909629-6

1/2"3/4"1"1-1/4"1-1/2"2"2-1/2"3"3-1/2"4"

25/25025/25050/20025201512653

Boxed9620962196229623962496259626962796289629

90° Conduit Elbow

Features:• Concretetight• Pre-set/pre-staked set screws• Combination head set screws

EMT 90º Dönüfl:90º lik EMT boru dönüfllerindekullan›l›r. 45º ve 30º dönüfllerdemevcuttur.

Use:To join lengths of steel EMTfor concretetight or dry locationapplications

Material/Finish:Steel/Zinc Plated

CONDUIT FITTINGSEmt Fittings/EMT Boru Aksesuarlar›

OFFSET

Figure 1

STRAIGHT

Figure 2

Page 6: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

Use:90° connectors are used to terminate steel EMTconduit to an unthreaded box or enclosure in dryor damp locations where a 90° bend is required.• Compression Type• Concrete -Tight• Rain-Tight

Use:90° connectors are used to terminate steel EMTconduit to an unthreaded box or enclosure in drylocations where a 90° bend is required.• Set Screw Type

90° EMT Connectors

90° EMT Connectors

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-31857 Size A B C Unit Qty/Qty Wt.

Boxed8358 18358-3 1/2" 1.43 1.19 0.48 - 20/200 29.68359 18359-0 3/4" 1.47 1.42 0.54 - 20/200 41.6

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8203 08203-9 1/2" 1.35 0.98 0.51 - 25/250 37.18204 08204-6 3/4" 1.47 0.42 0.52 - 20/200 54.0

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

Use:Set screw type offset connectors are used tomake a slight adjustment in terminating the end ofa run of steel EMT conduit to an enclosure or boxin dry locations.• Set Screw Type• Concrete-Tight when taped

EMT To Box Offset Connectors

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8300 08300-5 1/2" 2.09 0.92 0.41 - 10/100 10.68301 08301-2 3/4" 3.01 1.12 0.46 - 1 0/100 18.3

Materials:• Zinc Die-Cast

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

Use:Compression type offset connectors are used tomake a slight adjustment in terminating the end ofa run of steel EMT Conduit to an enclosure or boxin dry or damp locations.• Compression Type• Concrete -Tight

EMT To Box Offset Connectors

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-31857 Size A B C Unit Qty/Qty Wt.

Boxed8308 08308-1 1/2" 1.87 0.98 0.40 - 10/100 27.98309 08309-8 3/4" 2.63 1.22 0.46 - 10/100 22.2

Materials:• Zinc Die-Cast

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

S›kmal› Tip 90º Zamak Rakor(S›v› S›zd›rmaz) :EMT borular›n pano,buat, kutu gibi girifllerde90º ile sonland›r›lmas›ndakullan›l›r.

Vidal› Tip 90º Zamak RakorEMT borular›n pano,buat, kutu gibi girifllerde90º ile sonland›r›lmas›ndakullan›l›r.

Vidal› Kutu Ba¤lant›Zamak Rakoru:EMT borular›n pano,buat, kutu gibi girifllerde,borular›n farkl› seviyelerdebirlefltirilmesinde kullan›l›r.

S›kmal› Kutu Ba¤lant›Zamak Rakoru:EMT borular›n pano,buat, kutu gibi girifllerde,borular›n farkl› seviyelerdebirlefltirilmesinde kullan›l›r.

Materials:• Zinc Die-Cast

ELECTRICAL PRODUCTS

UL Listed: E155411CSA Certified:LR57925

Certification:

Materials:• Zinc Die-Cast

UL Listed: E155411CSA Certified:LR57925

Certification:

UL Listed: E210498CSA Certified:LR57925

Certification:

UL Listed: E210498CSA Certified:LR57925

Certification:

B 06

www.afielektrik.com

CONDUIT FITTINGSEmt Fittings/EMT Boru Aksesuarlar›

Page 7: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

Use:Pull elbows are used to facilitate pullingconductors through a 90° bend in a run of steelEMT Conduit. The removable cover gives ampleaccess so that wire pulling can be achievedwithout any obstruction.• Set Screw Type• Removable Aluminum Cover

EMT To EMT Pull Elbows

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8340 08340-1 1/2" 1.31 1.02 0.96 - 10/100 19.48341 08341-8 3/4" 1.37 1.28 1.18 - 5/50 15.08342 08342-5 1" 1.95 1.55 1.52 - 10 6.18343 08343-2 1 1/4" 2.32 1.92 1.88 - 5 4.7Boxed w/ Gasket8340-G 08415-6 1/2" 1.31 1.02 0.96 - 10/100 20.18341-G 08416-3 3/4" 1.37 1.28 1.18 - 5/50 14.38342-G 08357-9 1" 1.95 1.55 1.52 - 10 6.18343-G 08358-6 1 1/4" 2.32 1.92 1.88 - 5 4.8

Use:Pull elbows are used to facilitate pulling conductors througha 90° bend in a run of steel EMT Conduit. The removablecover gives ample access so that wire pulling can be achievedwithout any obstruction.• Set Screw Type• Removable Aluminum Cover

EMT To Box Pull ElbowsCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8330 08330-2 1/2" 1.31 1.02 0.96 - 10/100 20.18331 08331-9 3/4" 1.37 1.28 1.17 - 5/50 16.7Boxed w/ Gasket8330-G 08400-2 1/2" 1.31 1.02 0.96 - 10/100 21.68331-G 08401-9 3/4" 1.37 1.28 1.17 - 5/50 15.9

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

Materials:• Zinc Die-Cast

Use:Inside corner pull elbows are used to facilitate pullingconductors through a 90° bend in a run of steel EMT conduitwhere it is essential to make tight turns within limited availablespace. • Set Screw Type • Concrete-Tight when taped

Inside Corner Pull Elbows

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8215 08215-2 1/2" 1.80 0.93 0.72 10 10/100 20.98216 08216-9 3/4" 2.00 1.13 0.94 5 5/50 13.8

Materials:• Zinc Die-Cast

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

Use:Nail straps are used to secure steel EMT Conduitto wooden structure members. Can be used inplace of one or two hole straps.

EMT Nail Strap

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9377 09377-6 1/2" 2.00 0.350 - 100/1000 7.39378 09378-3 3/4" 2.12 0.46 - 100/1000 22.49379 09379-0 1" 2.25 0.58 - 100/1000 25.7

Materials:• Stamped Steel

Finish:• Zinc Plated

Kapakl› ‹zoleli 90º Zamak Dönüfl:EMT borular›n 90º dönüflünde kullan›l›r, vidal› kapa¤› sayesindekabloya kolayca müdahale edilebilmesini sa¤lar.

Kapakl› 90º Zamak Dönüfl:EMT borular›n 90º dönüflünde kullan›l›r, vidal› kapa¤›sayesinde kabloya kolayca müdahale edilebilmesini sa¤lar.

Materials:• Zinc Die-Cast

Standards:UL 514B, CSA C22.2 No. 18NEMA FB-1, NEC Article 348

Kapakl› 90º Zamak Dönüfl:EMT borular›n s›k›fl›k alanlarda 90º dönüflünde kullan›l›r, yandan aç›labilir olmas› sayesindekabloya kolayca müdahale edilebilmesini sa¤lar.

Döküm T›rnakl› Krofle:EMT borular›n ahflap yüzeyleresabitlenmesinde kullan›l›r.

ELECTRICAL PRODUCTS

UL Listed: E155411CSA Certified:LR57925

Certification:

UL Listed: E155411CSA Certified:LR57925

Certification:

UL Listed: E155411CSA Certified:LR57925

Certification:

www.afielektrik.comB 07

CONDUIT FITTINGSEmt Fittings/EMT Boru Aksesuarlar›

Page 8: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

B 08

www.afielektrik.com

Boxed9310 09310-3 1/2” 1.65 0.55 0.73 - 100/1000 12.89311 09311-0 3/4” 1.91 0.62 0.92 - 50/500 10.29312 09312-7 1” 2.30 0.75 1.15 - 50/500 15.39313 09313-4 1 1/4” 2.87 0.88 1.49 - 25/250 22.59314 09314-1 1 1/2” 3.14 1 1.85 - 25/100 15.29315 09315-8 2” 3.93 1.12 2.31 - 15/75 13.29316 09316-5 2 1/2” 4.90 1.25 3.00 - 25 11.69317 09317-2 3” 5.53 1.25 3.60 - 25 12.79318 09318-9 3 1/2” 6.18 1.25 4.13 - 25 17.59319 09319-6 4” 6.68 1.25 4.63 - 25 16.0

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

CONDUIT FITTINGSEmt Fittings/EMT Boru Aksesuarlar›

Use:One hole straps are used for providing support forsteel EMT Conduit as required by the NationalElectrical Code.• Click-On Type

Use:Two hole straps are used for providing support forsteel EMT Conduit where higher load bearingsupports are desired as required by the NationalElectrical Code.• Click-On Type

EMT One Hole Straps

EMT Two Hole Straps

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9330 09330-1 1/2” 2.12 0.55 0.73 - 50/500 17.69331 09331-8 3/4” 2.70 0.63 0.93 - 50/500 14.29332 09332-5 1” 3.01 0.68 1.11 - 50/200 17.69333 09333-2 1 1/4” 3.74 0.75 1.45 - 50 15.59334 09334-9 1 1/2” 4.21 0.86 1.68 - 50 20.39335 09335-6 2” 4.76 1.00 2.20 - 10/50 6.49336 09336-3 2 1/2” 5.88 1.00 2.91 - 25 5.19337 09337-0 3” 6.50 1.00 3.53 - 25 5.99338 09338-7 3 1/2” 7.38 1.00 4.03 - 25 8.39339 09339-4 4” 8.00 1.00 4.53 - 25 9.1

Finish:• Zinc Plated

Finish:• Zinc Plated

Standards:UL 2239, CSA C22.2 No. 18NEMA FB-1, NEC Article 348

Use:Conduit bodies are used to gain access to theinterior of a raceway for wire pulling, inspectionand maintenance where the raceway changesdirection. Assembled with Cover and Gasket.• Assembled with Cover and Gasket.

Set Screw LR Conduit Bodies

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

BoxedD100-CGV 15600-6 1/2” 4.30 1.30 2.40 - 27 7D101-CGV 15606-8 3/4” 5.00 1.50 2.60 - 15 7.5D102-CGV 15612-9 1” 5.80 1.80 2.90 - 14 9D103-CGV 15618-1 1 1/4” 7.80 2.50 3.70 - 4 5.5D104-CGV 15624-2 1 1/2” 7.80 2.50 3.90 - 4 6D105-CGV 15630-3 2” 9.80 3.20 4.70 - 2 4.516-CG 15775-1 2 1/2” 10.50 4.40 5.60 - 1 5.617-CG 15776-8 3” 10.50 4.50 6.00 - 1 6.518-CG 15777-5 3 1/2” 15.47 5.43 7.36 - 1 8.519-CG 15778-2 4” 15.47 5.43 7.36 - 1 8.6* "D" bodies are also threaded for rigid

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

Tek Delikli Sabitleme Kroflesi:Diflsiz EMT borular› duvara sabitlemede kullan›l›r. Materials:

• Stamped SteelStandards:UL 2239, CSA C22.2 No. 18NEMA FB-1, NEC Article 348

Materials:• Stamped Steel

Çift Delikli Sabitleme Kroflesi:Diflsiz EMT borular› duvara sabitlemede kullan›l›r.

Materials:• Aluminum Die-Cast• Stamped Aluminum Cover

Kondulet Buat :Boru tesisat›nda dirsek olarak dönüfllerde, kablo çekmedetesisat içindeki kablolara ek yapmakta kullan›l›r. Vidal›kapa¤› sayesinde kablo ek yerlerine müdaheleyikolaylaflt›r›r. Kapakla kodulet aras›ndaki toz ve sugeçirmez conta sayesinde IP-66 koruma s›n›f›na uygundur.

ELECTRICAL PRODUCTS

UL Listed: E121488CSA Certified:LR57925

Certification:

Page 9: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

www.afielektrik.comB 09

CONDUIT FITTINGSEmt Fittings/EMT Boru Aksesuarlar›

Use:Conduit bodies are used to gain access to theinterior of a raceway for wire pulling, inspectionand maintenance where the raceway changesdirection. Assembled with Cover and Gasket.• Assembled with Cover and Gasket.

Set Screw LL Conduit Bodies

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

BoxedD200-CGV 15636-5 1/2" 4.30 1.30 2.40 - 27 7D201-CGV 15642-6 3/4" 5.00 1.50 2.60 - 15 7.5D202-CGV 15648-8 1" 5.80 1.80 2.90 - 14 9D203-CGV 15654-9 1 1/4" 7.80 2.50 3.70 - 4 5.5D204-CGV 15660-0 1 1/2" 7.80 2.50 3.90 - 4 6D205-CGV 15666-2 2" 9.80 3.20 4.70 - 2 5.526-CG 15779-9 2 1/2" 10.50 4.40 5.60 - 1 5.627-CG 15780-0 3" 10.50 4.50 6.00 - 1 6.528-CG 15781-2 3 1/2" 15.47 5.43 7.36 - 1 8.529-CG 15782-9 4" 15.47 5.43 7.36 - 1 8.6* "D" bodies are also threaded for rigid

Standards: UL 514BCSA C22.2 No. 18NEMA FB-1 NEC Article 348

Use:Conduit bodies are used to gain access to theinterior of a raceway for wire pulling, inspectionand maintenance where the raceway changesdirection. Assembled with Cover and Gasket.• Assembled with Cover and Gasket.

Set Screw LB Conduit BodiesCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

BoxedD600-CGV 15708-9 1/2" 4.30 1.30 2.40 - 30 7D601-CGV 15714-7 3/4" 5.00 1.50 2.60 - 18 7.5D602-CGV 15720-1 1" 5.80 1.80 2.90 - 16 9D603-CGV 15726-3 1 1/4" 7.80 2.50 3.70 - 8 5.5D604-CGV 15732-4 1 1/2" 7.80 2.50 3.90 - 8 6D605-CGV 15738-6 2" 9.80 3.20 4.70 - 2 5.566-CG 18771-0 2 1/2" 10.50 4.40 5.60 - 1 4.567-CG 71741-2 3" 10.50 4.50 6.00 - 1 568-CG 15787-4 3 1/2" 15.47 5.43 7.36 - 1 9.569-CG 71751-1 4" 15.47 5.43 7.36 - 1 8.5* "D" bodies are also threaded for rigid

Standards: UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

Use:Conduit bodies are used to gain access to theinterior of a raceway for wire pulling, inspectionand maintenance where the raceway changesdirection. Assembled with Cover and Gasket.• Assembled with Cover and Gasket.

Set Screw T Conduit BodiesCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

BoxedD700-CGV 15744-7 1/2" 4.30 1.30 2.40 - 16 5D701-CGV 15750-8 3/4" 5.00 1.50 2.60 - 12 5.5D702-CGV 15756-0 1" 5.80 1.80 2.90 - 14 9D703-CGV 15762-1 1 1/4" 7.80 2.50 3.70 - 4 7.5D704-CGV 15768-3 1 1/2" 7.80 2.50 3.90 - 4 6.5D705-CGV 15774-4 2" 9.80 3.20 4.70 - 2 5.576-CG 15788-1 2 1/2" 10.50 4.40 5.60 - 1 5.677-CG 15789-8 3" 10.50 4.50 6.00 - 1 6.578-CG 15790-4 3 1/2" 15.47 5.43 7.36 - 1 8.579-CG 15791-1 4" 15.47 5.43 7.36 - 1 8.6* "D" bodies are also threaded for rigid

Materials:• Aluminum Die-Cast• Stamped Aluminum Cover

Kondulet Buat :Boru tesisat›nda dirsek olarak dönüfllerde, kabloçekmede tesisat içindeki kablolara ek yapmaktakullan›l›r. Vidal› kapa¤› sayesinde kablo ek yerlerinemüdaheleyi kolaylaflt›r›r. Kapakla kodulet aras›ndakitoz ve su geçirmez conta sayesinde IP-66 korumas›n›f›na uygundur.

Kondulet Buat :Boru tesisat›nda dirsek olarak dönüfllerde, kabloçekmede tesisat içindeki kablolara ek yapmaktakullan›l›r. Vidal› kapa¤› sayesinde kablo ek yerlerinemüdaheleyi kolaylaflt›r›r. Kapakla kodulet aras›ndakitoz ve su geçirmez conta sayesinde IP-66 korumas›n›f›na uygundur.

Materials:• Aluminum Die-Cast• Stamped Aluminum Cover

Kondulet “T” Buat :Boru tesisat›nda “T” ba¤lant› yapmakta, kabloçekmede tesisat içindeki kablolara ek yapmaktakullan›l›r. Vidal› kapa¤› sayesinde kablo ek yerlerinemüdaheleyi kolaylaflt›r›r. Kapakla kodulet aras›ndakitoz ve su geçirmez conta sayesinde IP-66 korumas›n›f›na uygundur.

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

ELECTRICAL PRODUCTS

UL Listed: E121488CSA Certified:LR57925

Certification:

UL Listed: E121488CSA Certified:LR57925

Certification:

UL Listed: E121488CSA Certified:LR57925

Certification:

Page 10: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

Use:Conduit bodies are used to gain access to theinterior of a raceway for wire pulling, inspectionand maintenance where the raceway changesdirection. Assembled with Cover and Gasket.• Assembled with Cover and Gasket.

Set Screw C Conduit BodiesCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

BoxedD300-CGV 15672-3 1/2" 4.30 1.30 2.40 - 24 6.5D301-CGV 15678-5 3/4" 5.00 1.50 2.60 - 18 7.5D302-CGV 15684-6 1" 5.80 1.80 2.90 - 14 9D303-CGV 15690-7 1 1/4" 7.80 2.50 3.70 - 8 12D304-CGV 15696-9 1 1/2" 7.80 2.50 3.90 - 8 11D305-CGV 15704-1 2" 9.80 3.20 4.70 - 2 536-CG 15783-6 2 1/2" 10.50 4.40 5.60 - 1 6.537-CG 15784-3 3" 10.50 4.50 6.00 - 1 7.538-CG 15785-0 3 1/2" 15.47 5.43 7.36 - 1 939-CG 15786-7 4" 15.47 5.43 7.36 - 1 12* "D" bodies are also threaded for rigid

Standards:UL 514B CSA C22.2 No. 18NEMA FB-1 NEC Article 348

Materials:• Aluminum Die-Cast• Stamped Aluminum Cover

ELECTRICAL PRODUCTS

UL Listed: E121488CSA Certified:LR57925

Certification:

Kondulet “C” Buat :Boru tesisat›nda ba¤lant› yapmakta, kabloçekmede tesisat içindeki kablolara ek yapmaktakullan›l›r. Vidal› kapa¤› sayesinde kablo ek yerlerinemüdaheleyi kolaylaflt›r›r. Kapakla kodulet aras›ndakitoz ve su geçirmez conta sayesinde IP-66 korumas›n›f›na uygundur.

Use:Combination couplings are used to provide atransition from steel EMT conduit to Flexible MetalConduit.• Set Screw - Clamp Type

EMT To Flex Couplings

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8217 08217-6 1/2"-3/8" 0.72 0.93 1.34 - 50/500 34.3

Materials:• Zinc Die-Cast

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348 & 350Vidal› EMT - Spiral Zamak Boru Geçifl Mufu :

EMT borudan spiral çelik boruya geçifllerde kullan›l›r.

UL Listed: E210498CSA Certified:LR57925

Certification:

Use:Combination couplings are used to provide atransition from steel EMT conduit to Flexible MetalConduit.• Set Screw - Squeeze Type

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8218 08218-3 1/2"-1/2" 0.93 0.94 1.62 - 25/250 21.98219 08219-0 3/4"-3/4" 0.94 01.12 1.97 - 25/250 36

Vidal› EMT - Spiral Zamak Boru Geçifl Mufu :EMT borudan spiral çelik boruya geçifllerde kullan›l›r.

UL Listed: E210498CSA Certified:LR57925

Certification:Materials:• Zinc Die-Cast

B 10

www.afielektrik.com

CONDUIT FITTINGSEmt Fittings/EMT Boru Aksesuarlar›

Page 11: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

www.afielektrik.comB 11

CONDUIT FITTINGSEmt Fittings/EMT Boru Aksesuarlar›

Use:Combination couplings are used to provide atransition from steel EMT Conduit to Flexible MetalConduit.• Compression - Screw in Type

EMT To Flex Couplings

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8210 08210-7 1/2" 1.40 0.92 0.15 - 50/500 40.98211 08211-4 3/4" 1.52 1.12 0.20 - 25/250 30.8

Use:Combination couplings are used to provide atransition from steel EMT conduit to RigidConduit.• Compression - Threaded Type

EMT Compression ToRigid Couplings

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9460 09460-5 1/2" 1 5/16" 1 1/8" 7/8" 11/16" 10/100 13.79461 09461-2 3/4" 1 7/16" 1 3/8" 1 1/8" 3/4" 10/100 25.19462 09462-9 1" 1 1/2" 1 11/16" 1 3/8" 13/16" 10/100 33.3

Standards:UL 514B CSA C22.2 No. 18NEMA FB-1 NEC Articles 348 & 350

Materials:• Zinc Die-Cast

S›kmal› EMT - Spiral Zamak Boru Geçifl Mufu :EMT borudan spiral çelik boruya geçifllerde kullan›l›r.

S›kmal› EMT - Rigid Boru Çelik Geçifl Mufu :EMT borudan rigid boruya geçifllerde kullan›l›r.IMC/Rigid taraf› diflli, EMT taraf› s›kmal›d›r.

Standards:UL 514NEMA FB-1

Materials:• Steel

Certification:

E207875

Use:Combination couplings are used to provide atransition from steel EMT Conduit to RigidConduit.• Set Screw - Set Screw Type

EMT Set Screw ToRigid Couplings

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9463 09463-6 1/2" 1" 2 3/8" 7/8" 15/16" 25/250 34.39464 09464-3 3/4" 1 1/4" 2 13/16" 1 1/8" 1 1/8" 10/100 25.19465 09465-0 1" 1 1/2" 3" 1 3/8" 1 13/16" 10/100 33.3

Materials:• Steel

Certification:

E207875

Standards:UL 514BNEMA FB-1E207875

Vidal› EMT - Rigid Boru Çelik Geçifl Mufu :EMT borudan rigid boruya geçifllerde kullan›l›r.

ELECTRICAL PRODUCTS

UL Listed: E155411CSA Certified:LR57925

Certification:

Page 12: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

B 12

www.afielektrik.com

CONDUIT FITTINGSEmt Fittings/EMT Boru Aksesuarlar›

EMT/Rigid Clamp Backs

1-Hole StrapsFor Rigid Conduit. Malleable.

ELECTRICAL PRODUCTS

Catalog UPC No Trade Ctn/Case CaseNumber 0-31857 Size Qty/Qty Wt.

Boxed9500 09500-8 1/2" 25/250 27.79501 09501-5 3/4" 25/250 29.29502 09502-2 1" 25/125 20.49503 09503-9 1 1/4" 20/100 22.39504 09504-6 1 1/2" 10/100 21.69505 09505-3 2" 5/50 30.99506 09506-0 2 1/2" 10 7.69507 09507-7 3" 10 10.59508 09508-4 3 1/2" 10 15.69509 09509-1 4" 10 17.1

Use:Used to provide space between steel conduitsand mounting surface.

Döküm Boru Destek Aparat›:Metal borular›n kullan›ld›¤› yüzeyle aras›nda destekolarak kullan›l›r. Rijidli¤i sa¤lar.

Materials:• Malleable iron

Finish:• Zinc Plated

Standards: CSA File No. LR57925

Boxed9510 09500-7 1/2" 25/250 27.79511 09501-4 3/4" 25/250 29.29512 09502-1 1" 25/125 20.49513 09503-0 1 1/4" 20/100 22.39514 09504-5 1 1/2" 10/100 21.69515 09505-2 2" 5/50 30.99516 09506-9 2 1/2" 10 7.69517 09507-6 3" 10 10.59518 09508-3 3 1/2" 10 15.69519 09509-0 4" 10 17.1

Catalog UPC No Trade Ctn/Case CaseNumber 0-31857 Size Qty/Qty Wt.

Use:To support Steel Conduits.

Döküm Boru Kroflesi :Metal borular›n desteklenmesinde kullan›l›r.

Materials:• Malleable iron

Finish:• Zinc Plated

Standards: CSA File No. LR57925

Page 13: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

ALL DIMENSIONS PROVIDED ARE FOR DESCRIPTIVE PURPOSES ONLY

INTERMEDIATE METAL CONDUIT ELBOWS

IMC Elbows 90˚

Material/Finish:Steel/Zinc Plated

ELECTRICAL PRODUCTS

UL Listed: E2104981CSA Certified:LR57925

Certification:

UL Listed: E210498CSA Certified:LR57925

Certification:

UL Listed: E22335CSA Cert i f ied:

Certification:

CatalogNumber

1/23/411 1/41 1/222 1/233 1/24

6 3/8”7 5/8”8 7/8”11 1/2”12 3/4”15 1/4”19 1/8”24 1/2”25 1/4”25 3/4”

264134454648450525450500

5282136225306480900150018002000

50502520151050352525

1 3/4”2 1/4”2 3/8”2 5/8”2 5/8”4”4 3/8”7 3/4”6 3/4”5 1/2”

TradeSize

OffsetFig. 1

StraightFig. 2

StandardCarton

Weight - PoundsPer 100 Per Ctn.

IMC-ELL050IMC-ELL075IMC-ELL100IMC-ELL125IMC-ELL150IMC-ELL200IMC-ELL250IMC-ELL300IMC-ELL350IMC-ELL400

Dimensions in InchesA B

1.02 1.571.28 1.942.53 2.271.99 2.632.23 2.942.69 3.503.26 4.013.90 4.514.46 5.004.97 5.26

CatalogNumber

8120812181228123812481258126812781288129

Trade Size(inches)

1/4

3/4

1/2

11122334

1/2

1/2

1/2

Set-Screw Style

Vidal› Zamak Muf:IMC-RMC borular›n birlefltirilmesindekullan›l›r.

Use:To join lengths of steel IMC-RMCfor concretetight or dry locationapplications

Dimensions in InchesA B

3.63 3.273.52 3.893.77 4.404.06 4.89

CatalogNumber

8136813781388139

3

4

Trade Size(inches)

2

3

1/2

1/2

8126

8136

Applicable Third Party Standards:

UL Standard:514BCSA Standard:C22.2 No.18NEMA : FB-1Fed.Spec: W-F-480EType 2, Class 2, Kind K

Applicable Third Party Standards:

UL Standard:514BCSA Standard:C22.2 No.18NEMA : FB-1Fed.Spec: W-F-480EType 2, Class 2, Kind K

8120

www.afielektrik.comB 13

CONDUIT FITTINGSIMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar›

IMC 90˚ Dönüfl :90˚ lik IMC boru dönüfllerindekullan›l›r. 45˚ ve 30˚ dönüfllerdemevcuttur.

For IMC & Threadless Rigid Conduit

Material/Finish:Zinc Die Cast

S›kmal› Zamak Muf:IMC-RMC borular›nbirlefltirilmesindekullan›l›r.

Compression Style

Use:To join lengths of steel IMC-RMCfor concretetight or dry locationapplications

Material/Finish:Zinc Die Cast

Use:To join lengths of steel IMC-RMCfor concretetight or dry locationapplications

Page 14: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

ELECTRICAL PRODUCTS

Applicable Third PartyStandards:

UL Standard:514BNEMA : FB-1

UL Listed: E256711Certification:

UL Listed: E256711Certification:

CatalogNumber

L-100-DL-200-DL-300-DL-300-DL-500-DL-600-DL-700-DL-800-DL-900-DL-1000-D

Trade Size(inches)

11122334

3/4

1/4

1/2

1/2

1/2

1/2

1/41/41/43/83/81/21/21/21/2

Aluminium Lenght

RB-321ARB-322ARB-323ARB-324ARB-325ARB-326ARB-327ARB-328ARB-329ARB-330ARB-331ARB-332ARB-333ARB-334ARB-335ARB-336ARB-337ARB-339ARB-340ARB-341ARB-342ARB-349ARB-350ARB-351ARB-355ARB-356ARB-357A

111111111111

CatalogNumber

RB-321SRB-322SRB-323SRB-324SRB-325SRB-326SRB-327SRB-328SRB-329SRB-320SRB-331RB-332RB-333RB-334RB-335RB-336RB-337RB-339RB-340RB-341RB-342RB-349RB-350RB-351RB-355RB-356RB-357

Trade Size(inches)

3/4 - 1/21 - 3/41 - 1/21 - 1/4-1/21 - 1/4-3/411/4 - 111/2 - 11/411/2 - 11 1/2 - 3/41 1/2 - 1/22 - 11/22 - 11/42 - 12 - 3/42 - 1/22 1/2 - 22 1/2 - 11/22 1/2 - 13 - 11/23 - 23 - 2 1/23 1/2 - 33 1/2 - 2 1/24 - 24 - 2 1/24 - 34 - 31/2

23/3223/3223/3213/1613/1613/1613/1613/1613/1613/167/87/87/87/87/8

B 14

www.afielektrik.com

CONDUIT FITTINGSIMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar›

Reducing Bushing Flush TypeUse:To reduce the trade size of a taperedentry on a conduit fitting.Kilitleme Somunu :IMC-RMC Borular›n girifl ölçülerininde¤ifltirilmesinde kullan›l›r.NOTE: For larger sizes useO-Z/Gedney Type RBFeatures:• Threaded for rigid conduit and IMCMaterial/Finish:Steel / Zinc Plated

Type RB

Bonding WedgeUse:Used with bushings to bond threaded rigidconduit and IMC to boxes, cabinets orother enclosures where locknut is exposed.Kilitleme Somunu :IMC-RMC Borular›n ve rakorlar›n buat,kutu, pano ve benzeri yerlere tak›ld›ktansonra kilitlenip sabitlenmesini sa¤lar.Features:Threaded for rigid conduit and IMC

Material/Finish:Steel / Zinc Plated

Applicable Third Party Standards:

UL Standard:514BNEMA : FB-1

Type GL

Page 15: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

IMC / RMC to EMT Conduit Compression Couplings

IMC / RMC EMT geçifl mufu:Diflli IMC / RMC borulardan diflsiz EMTborulara geçiflte kullan›lan s›kmal›tip ba¤lant› muflar›d›r.Features:* Threaded rigid and IMC to compression EMT* Concretetight* NPT female Hubs

Trade Size(inches)

2334

1/2

1/2

CatalogNumber

8106810781088109

ELECTRICAL PRODUCTS

Zamak Vidal› Tip IMC - RMCBoru Rakoru:IMC-RMC borular›n pano, buat,armatür ve benzeri yerlereba¤lant›s›nda kullan›l›r.

UL Standard: 514BCSA Standard: C22.2 No. 18NEMA: FB-1Fed. Spec: W-F-408E,Type 2, Class 2, Kind L, Style 1

Applicable Third Party Standards:

InsulatedThroatCatalog Dimensions in InchesNumber A B C

2.86 0.99 3.292.90 1.01 3.892.95 1.10 4.392.73 1.00 4.95

8156815781588159

CatalogNumber

8146814781488149

Trade Size(inches)

2334

1/2

1/2

UL Standard: 514BCSA Standard: C22.2 No. 18NEMA: FB-1Fed. Spec: W-F-408E,Type 2, Class 2, Kind L, Style 1

Applicable Third Party Standards:

Zamak S›kmal› Tip IMC - RMCBoru Rakoru:IMC-RMC borular›n pano, buat,armatür ve benzeri yerlereba¤lant›s›nda kullan›l›r.

8146

UL Listed: E256711CSA Certified:

Certification:

UL Listed: E2106711CSA Certified:LR57925

Certification:

UL Listed: E210498CSA Certified:LR57925

Certification:

‹NÇ OLARAK ÖLÇÜLERUZUNLUK MAX. ÇAP

111112

111223

CatalogNumber

ETR-50ETR-75ETR-100ETR-125ETR-150ETR-200

1/23/4

1/41/2

TradeSize(inches)

1112

3/85/161/27/87/85/16

1/8

3/8

3/4

3/8

1/2

Material / Finish:Malleable Iron/Zinc Plated

www.afielektrik.comB 15

CONDUIT FITTINGSIMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar›

For IMC & Threadless Rigid Conduit

8106

Set-Screw Coupling

Material/Finish:Zinc Die Cast

Use:Set-screw type connectors are used tosecure and terminate steel or aluminum,EMT, rigid or IMC conduits to knockouts inconcretetight or dry location applications.Concretetight when taped.

Material/Finish:Zinc Die Cast

Applicable Third Party Standards:UL Standard:514BNEMA : FB-1

Use:Compression type connectors are used tosecure and terminate steel or aluminum,EMT, rigid or IMC conduits to knockouts inconcretetight box, dry, or damp locationapplications. Concretetight.

Compression Style Coupling

InsulatedThroatCatalog Dimensions in InchesNumber A B C

3.10 1.07 3.273.31 1.60 3.913.56 1.03 4.513.76 1.11 4.97

8116811781188119

Page 16: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

Applications: Ideal forpharmaceutical, chemical and foodprocessing, pulp/paper and nuclearindustries. Resistant to a varietyof chemicals, including acetic, citricand salt water. The O-ring is aspecial and has excellent chemicalresistance. Hub is provided with asteel ground nut.

CONDUIT HUBThreaded Die Cast Zinc

CONDUIT GROUND HUBThreaded Die Cast Zinc

Catalog # Unit Standard Weight Lbs.Number Size Quantity Package Per 100

8490 3/8” 25 250 128491 1/2” 25 375 208492 3/4” 25 250 328493 1” 25 250 408494 1 1/4” 10 100 608495 1 1/2” 10 100 708496 2” 10 60 908497 2 1/2” 5 50 2008498 3” 2 30 2508499 3 1/2” 2 12 3008500 4” 2 12 3508501 5” 1 8 6008502 6” 1 8 800* not supplied with insulator.

Max. CopperCatalog # Unit Std. Weight Lbs. Grd.Wire SizeNumber Size Quantity Pkg. Per 100 CSA UL

8480 1/2” 25 325 20 #8 #88481 3/4” 25 225 30 #8 #88482 1” 25 150 43 #8 #88483 1 1/4” 10 100 55 #8 #88484 1 1/2” 10 90 73 #6 #88485 2” 10 60 95 #4 #88486 2 1/2” 5 35 190 #2 #88487 3” 2 26 263 1/0 #68488 3 1/2” 2 12 300 2/0 #68499 4” 2 12 350 2/0 #48490* 5” 1 8 625 2/0 #28491* 6” 1 8 750 3/0 #1* Not supplied with insulator.

Diflli Zamak Rakor:Ucu diflli borular›n pano, kutu, buatgirifllerinde sonland›r›lmas›ndakullan›l›r.‹laç ve g›da sanayiinde, ka¤›t venükleer enerji tesislerinde kullan›miçin uygundur. Contas› tuzlu su vekimyasallara dayan›kl›d›r.

Applications: Ideal forpharmaceutical, chemical and foodprocessing, pulp/paper and nuclearindustries. Resistant to a varietyof chemicals, including acetic, citricand salt water. The O-ring is aspecial and has excellent chemicalresistance. Hub is provided with asteel ground nut.

Diflli Zamak Rakor:Ucu diflli borular›n pano, kutu, buatgirifllerinde sonland›r›lmas›ndakullan›l›r.‹laç ve g›da sanayiinde, ka¤›t venükleer enerji tesislerinde kullan›miçin uygundur. Contas› tuzlu su vekimyasallara dayan›kl›d›r.

ELECTRICAL PRODUCTS

UL Listed: E210498CSA Certified:LR57925

Certification:

UL Listed: E210498CSA Certified:LR57925

Certification:

B 16

www.afielektrik.com

CONDUIT FITTINGSIMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar›

Page 17: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

Use:Used to connect two lenghts of threadedrigid conduit or IMC,when neitherconduit can be turned.Cast of high strength malleable iron andzinc plated.• Concrete-TightMaterials:• Malleable Iron

Three Piece Couplings

Use:Compression type connectors are used tosecure and terminate threadless Rigid orIMC Conduits toa steel outlet box or metalenclosure.• Concrete-TightMaterials:• Steel

Compression Connectors

Boxed9280 09280-9 1/2" 1.31 1.13 0.50 - 20/200 23.49281 09281-6 3/4" 1.48 1.37 0.52 - 10/100 18.59282 09282-3 1" 1.53 1.69 0.64 - 5/50 18.09283 09283-0 1 1/4" 1.70 2.07 0.68 - 5/50 25.09284 09284-7 1 1/2" 1.96 2.28 0.72 - 12 13.09285 09285-0 2" 2.07 2.79 0.72 - 12 10.2

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-31857 Size A B C Unit Qty/Qty Wt.

Çelik S›kmal› Tip IMC - RMCBoru Rakoru:IMC-RMC borular›n pano, buat,armatür ve benzeri yerlereba¤lant›s›nda kullan›l›r.

Döküm S›kmal› Tip IMC - RMCBoru Rakoru:Diflli borular›n hareket imkan› bulunmad›¤›durumlarda borular› birlefltirmek için kullan›l›r.

ELECTRICAL PRODUCTS

UL Listed: E155411CSA Certified:LR57925

Certification:

UL Listed: E155411CSA Certified:LR57925

Certification:

Boxed9520 09520-6 1/2" 1.64 1.13 0.85 - 10/100 20.49521 09521-3 3/4" 1.80 1.37 1.07 - 5/50 12.99522 09522-0 1" 1.88 1.69 1.29 - 5/50 25.29523 09523-7 1 1/4" 2.09 2.07 1.61 - 5/25 22.39524 09524-4 1 1/2" 2.40 2.28 1.85 - 5/25 30.79525 09525-1 2" 2.33 2.78 2.33 - 20 36.89526 09526-8 2 1/2" 2.09 2.07 1.61 - 10 31.09527 09527-5 3" 2.40 2.28 1.85 - 5 16.09528 09528-2 3 1/2" 2.33 2.78 2.33 - 5 29.89529 09529-9 4" 2.33 2.78 2.33 - 2 15.1

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-31857 Size A B C Unit Qty/Qty Wt.

Use:Compression type couplings are used tojoin wo lengths of threadless Rigid or IMCConduits.• Concrete-TightMaterials:• Steel

Compression Couplings

Çelik S›kmal› Tip IMC - RMCEk Mufu:IMC-RMC borular›n birbirlerineba¤lant›s›nda kullan›l›r.

Boxed9290 09290-8 1/2" 1.64 1.13 0.85 - 10/100 30.19291 09291-5 3/4" 1.80 1.37 1.07 - 10/100 25.59292 09292-2 1" 1.88 1.69 1.29 - 5/50 22.09293 09293-9 1 1/4" 2.09 2.07 1.61 - 5/50 33.09294 09294-6 1 1/2" 2.40 2.28 1.85 - 12 10.09295 09295-3 2" 2.33 2.78 2.33 - 12 12.0

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-31857 Size A B C Unit Qty/Qty Wt.

UL Listed: E155411CSA Certified:LR57925

Certification:

www.afielektrik.comB 17

CONDUIT FITTINGSIMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar›

Page 18: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

Use:Compression type connectors are used to secureand terminate threadless Rigid or IMC Conduits toa steel outlet box or metal enclosure.• Concrete-TightMaterials:• Malleable Iron

Compression Rigid Connectors

Use:Compression typecouplings are used to jointwo lengths of threadlessRigid or IMC Conduit.• Concrete-TightMaterials:• Malleable Iron

Boxed9160 09160-4 1/2" 1 1/2" 1/2" 1 1/2" 25/250 50.89161 09161-1 3/4" 1 1/2" 1/2" 1 5/8" 25/250 55.89162 09162-8 1" 1 11/16" 9/16" 2" 25/100 33.79163 09163-5 1 1/4" 2" 11/16" 2 3/8" 5/50 26.09164 09164-2 1 1/2" 2 1/16" 11/16" 2 5/8" 5/50 32.79165 09165-0 2" 2 1/4" 7/8" 3 5/16" 20 21.49166 09166-6 2 1/2" 2 15/16" 1 1/4" 3 3/4" 5 12.19167 09167-3 3" 3 1/8" 1 3/8" 4 1/4" 3 8.99168 09168-0 3 1/2" 3 1/8" 1 3/8" 4 3/4" 2 7.79169 09169-7 4" 3 3/8" 1 1/2" 5 5/16" 2 9.4Boxed w/ insulated throat9170 09170-3 1/2" 1 9/16" 9/16" 1 1/2" 25/250 51.39171 09171-0 3/4" 1 9/16" 9/16" 1 5/8" 25/250 56.59172 09172-7 1" 1 3/4" 5/8" 2" 25/100 34.19173 09173-4 1 1/4" 2" 11/16" 2 3/8" 5/50 26.39174 09174-1 1 1/2" 2 1/8" 3/4" 2 5/8" 5/50 33.09175 09175-8 2" 2 5/16" 13/16" 3 5/16" 20 22.79176 09176-5 2 1/2" 3" 1 5/16" 3 3/4" 5 12.39177 09177-2 3" 3 1/8" 1 7/16" 4 1/4" 3 9.09178 09178-0 3 1/2" 3 3/16" 1 1/2" 4 3/4" 2 7.89179 09179-6 4" 3 7/16" 1 9/16" 5 5/16" 2 9.4

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-31857 Size A B C Qty/Qty Wt.

Use:Pull elbows are used to facilitate pullingconductors through a 90° bend in a run of Rigid orIMC conduit. The removable cover gives ampleaccess so that wire pulling can be achievedwithout any obstructions.• Removable Aluminum Cover

Boxed W/O Gasket8345 08345-6 1/2" 1.31 1.02 0.96 10/100 18.88346 08346-3 3/4" 1.37 1.28 1.26 5/50 13.3Boxed With Gasket8345-G 08359-3 1/2" 1.31 1.02 0.96 10/100 19.68346-G 08349-4 3/4" 1.37 1.28 1.26 5/50 13.78347-G 08347-0 1" 1.95 1.55 1.52 25 15.68348-G 08348-7 1 1/4" 2.32 1.92 1.88 20 18.8

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

StandardsUL514B CSA C22.2 No. 18NEMA FB-1 NEC Article 345 & 346

Compression Rigid Coupling

Döküm S›kmal› Tip IMC - RMCBoru Rakoru:IMC-RMC borular›n pano, buatgirifllerinde kullan›l›r.

Boxed9180 09180-2 1/2" 1 13/16" 1/2" 1 1/2" 10/100 30.09181 09181-0 3/4" 1 7/8" 1/2" 1 5/8" 10/100 32.09182 09182-6 1" 2 3/16" 9/16" 2" 5/50 21.99183 09183-3 1 1/4" 2 5/8" 3/4" 2 3/8" 5/50 38.89184 09184-0 1 1/2" 2 11/16" 11/16" 2 5/8" 12 11.29185 09185-7 2" 3 1/16" 15/16" 3 5/16" 5 8.09186 09186-4 2 1/2" 4 1/2" 2" 3 3/4" 5 13.89187 09187-1 3" 4 15/16" 2 1/4" 4 1/4" 3 11.89188 09188-8 3 1/2" 5" 2 1/4" 4 3/4" 2 10.99189 09189-5 4" 5 5/16" 2 7/16" 5 5/16" 2 12.5

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-31857 Size A B C Qty/Qty Wt.

Döküm S›kmal› Tip IMC - RMCBoru Mufu:IMC-RMC borular›n birlefltirilmesinde kullan›l›r.

Kapakl› Döküm 90º Dönüfl:IMC ve Rigid borular›n 90˚ dönüflündekullan›l›r, vidal› kapa¤› sayesinde kabloyakolayca müdahale edilebilmesini sa¤lar.

Materials• Zinc Die-Cast• Neoprene Gasket

Rigid to Rigid Pull Elbows

ELECTRICAL PRODUCTS

UL Listed: E155411CSA Certified:LR57925

Certification:

UL Listed: E155411CSA Certified:LR57925

Certification:

UL Listed: E155411CSA Certified:LR57925

Certification:

www.afielektrik.com

CONDUIT FITTINGSIMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar›

B 18

Page 19: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

Use:Pull elbows are used to facilitate pullingconductors through a 90° bend in a run of Rigid orIMC conduit. The removable cover gives ampleaccess so that wire pulling can be achievedwithout any obstructions.• Removable Aluminum Cover

Threaded Couplings

Box Spacers

Use:Box spacers are used for providing araceway between two steel outlet boxes ormetal enclosures by connecting either sideby side or back to back.• Locknut not Included

StandardsUL514B CSA C22.2 No. 18NEMA FB-1 NEC Article 345 & 346

Boxed W/O Gasket8335 08335-7 1/2" 1.31 1.02 0.96 10/100 18.38336 08336-4 3/4" 1.37 1.28 1.18 5/50 13.0Boxed With Gasket8335-G 08405-7 1/2" 1.31 1.02 0.96 10/100 19.28336-G 08414-9 3/4" 1.37 1.28 1.18 5/50 13.3

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

StandardsUL514B CSA C22.2 No. 18NEMA FB-1 NEC Article 345 & 346

Kapakl› Döküm 90º Dönüfl:IMC ve Rigid borular›n kutu ve panolaragiriflinde 90˚ aç›yla sabitlenmesinisa¤lar.

Rigid to Box Pull Elbows

Materials• Zinc Die-Cast• Neoprene Gasket

Materials• Zinc Die-Cast

Zamak Kutu Ba¤lant› Parças›:Kutular›n ve panolar›n yanyana ya daarka arkaya ba¤lant›s›nda kullan›l›r.

ELECTRICAL PRODUCTS

UL Listed: E155411CSA Certified:LR57925

Certification:

UL Listed: E155411CSA Certified:LR57925

Certification:

Boxed9000 09000-3 1/2" 1 5/8" 1" 100 12.69001 09001-0 3/4" 1 5/8" 1 1/4" 50 8.09002 09002-7 1" 2" 1 1/2" 30 8.39003 09003-4 1 1/4" 2 1/16" 1 7/8" 25 8.39004 09004-1 1 1/2" 2 1/8" 2 1/8" 25 11.09005 09005-0 2" 2 3/16" 2 5/8" 20 14.19006 09006-5 2 1/2" 3 3/16" 3 3/16" 12 20.49007 09007-2 3" 3 1/4" 3 13/16" 8 16.49008 09008-9 3 1/2" 3 7/16" 4 1/2" 4 10.69009 09009-6 4" 3 1/2" 4 13/16" 4 13.9

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B Qty/Qty Wt.

Materials• Steel

StandardsUL6NEC Article 345 & 346

UL Listed: E155411CSA Certified:LR57925

Certification:

Use:Threaded couplings are used to join twolengths of threaded Rigid or IMC Conduit.

Çelik Diflli Ek Mufu:IMC ve Rigid borular›n birlefltirilmesindekullan›l›r.

Boxed8202 08202-2 1/2" 1.12 0.40 0.62 50/500 38.6

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

www.afielektrik.comB 19

CONDUIT FITTINGSIMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar›

Page 20: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

UseConduit locknuts are used for securing Rigid andIMC Conduits and other threaded connectors to asteel outlet box or metal enclosure.Çelik Kilitleme Somunu:Ucu diflli borular›n ve rakorlar›n buat, kutu,pano ve benzeri yerlere tak›ld›ktan sonrakilitlenip sabitlenmesini sa¤lar.

Conduit LocknutsBoxed131 70805-2 3/8” 1.12 0.09 1.00 100/1000 11.5132 70810-6 1/2” 1.37 0.10 1.25 100/1000 11.4133 70815-1 3/4” 1.75 0.12 1.56 100/1000 16.2134 70820-5 1” 2.12 0.12 1.91 100/1000 27.2149 70825-0 1 1/4” 2.43 0.12 2.16 50/500 18.9150 70830-4 1 1/2” 2.93 0.12 2.68 50/500 25.2151 70835-9 2” 3.56 0.17 3.25 40/400 29.3152 70840-3 2 1/2” 4.18 0.17 3.95 30/300 44.4153 70845-8 3” 5.37 0.17 5.00 25/250 43.0154 70850-2 3 1/2” 2.93 0.12 2.68 25/125 18.3155 70855-7 4” 3.56 0.17 3.25 20/100 26.0156 70860-1 5” 4.18 0.17 3.95 10/30 23.5157 70865-6 6” 5.37 0.17 5.00 10/30 26.5

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

ELECTRICAL PRODUCTS

Certification

E155411 LR57925

Materials• Steel

Finish• Zinc Plated

www.afielektrik.com

Use:Conduit locknuts are used for securing Rigid andIMC Conduits and other threaded connectors toa steel outlet box or metal enclosure.• Single Cast Thread• Fully Reversible• Creates a 360° Ground path• UL Listed Stand Alone for Rigid Conduit

Zamak Kilitleme Somunu:Ucu diflli borular›n ve rakorlar›n buat, kutu,pano ve benzeri yerlere tak›ld›ktan sonrakilitlenip sabitlenmesini sa¤lar.

Boxed8450 08450-2 1/2” 1.10 0.14 0.98 100/1000 21.08451 08451-9 3/4” 1.35 0.14 1.24 100/1000 15.08452 08452-6 1” 1.68 0.18 1.51 100/1000 22.08453 08453-3 1 1/4” 2.06 0.21 1.88 50/500 15.08454 08454-0 1 1/2” 2.38 0.21 2.21 20/200 15.08455 08455-7 2” 2.92 0.21 2.75 25/250 11.08456 08456-4 2 1/2” 3.52 0.29 3.24 10/100 6.0

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

Die-Cast Locknuts

StandardsUL514BCSA C22.2 No. 18NEMA FB-1NEC Article 345 & 346

Certification

E155411 LR57925

Materials• Zinc Die-Cast

Use:Plastic insulating bushings are used on the end ofRigid and IMC Conduits and other threadedconnectors to provide a smooth well roundedbearing surface to protect wires or cables.• Rated 105ºC• Flame Retardant‹zoleli Plastik Sonlama:Polypropilenden imal edilen plastik bushinglerdiflli borular›n direk olarak yada rakor ilesonland›r›lmas›nda kullan›l›r. Kablolar›nzedelenmeden çekilmesini sa¤lar 105º yakadar güvenle kullan›labilir. ‹zolesi sayesindes›zd›rmazl›k sa¤lar.

Plastic Insulating Bushings

StandardsUL 514BCSA C22.2 No. 18NEMA FB-1

Certification

E155411 LR57925Materials• Thermoplastic

Boxed171 09003-4 1/2” 1.04 0.39 0.60 100/1000 7.4172 70710-9 3/4” 1.27 0.41 0.78 100/1000 9.7173 70715-4 1” 1.55 0.56 1.00 50/500 9.6174 70720-8 1 1/4” 1.90 0.57 1.33 25/250 7.4175 70725-3 1 1/2” 2.18 0.57 1.54 50 1.9176 70730-7 2” 3.17 0.73 2.36 50 2.3177 70735-2 2 1/2” 3.17 0.73 2.36 25 2.0178 70740-6 3” 3.80 0.76 3.00 25 2.4179 70745-1 3 1/2” 3.80 0.76 3.00 25 2.4170 70750-5 4” 3.80 0.76 3.00 25 2.4

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

CONDUIT FITTINGSIMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar›

B 20

Page 21: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

Use:Insulated Metallic Conduit bushings are used onthe end of Rigid and IMC Conduits and otherthreaded connectors to provide a smooth wellrounded bearing surface to protect wires orcables.• Thermoplastic Liner Rated 105°C

Insulated Metallic Conduit Bushings

ELECTRICAL PRODUCTS

Materials• Zinc Die-Cast

StandardsUL 514B CSA C22.2 No. 18NEMA FB-1 NEC Article 345 & 346

Certification

E155411 LR57925

Boxed8260 08260-2 1/2" 1.28 0.42 0.54 100/1000 29.98261 08261-9 3/4" 1.53 0.42 0.74 50/500 21.98262 08262-6 1" 1.86 0.5 0.96 25/250 15.48263 08263-3 1 1/4" 2.16 0.51 1.27 25/250 24.78264 08264-0 1 1/2" 2.63 0.52 1.49 10/100 11.98265 08265-0 2" 2.72 0.51 1.95 10/100 14.98266 08266-4 2 1/2" 3.22 0.83 2.32 10 4.18267 08267-1 3" 3.85 0.83 2.92 10 4.88268 08268-8 3 1/2" 3.22 0.83 2.32 10 4.18269 08269-5 4" 3.85 0.83 2.92 10 4.8Boxed w/insulated throat8250 08250-3 1/2" 1.28 0.42 0.54 100/1000 29.98251 08251-0 3/4" 1.53 0.42 0.74 50/500 21.98252 08252-7 1" 1.86 0.5 0.96 25/250 15.48253 08253-4 1 1/4" 2.16 0.51 1.27 25/250 24.78254 08254-0 1 1/2" 2.63 0.52 1.49 10/100 11.98255 08255-0 2" 2.72 0.51 1.95 10/100 14.98256 08256-5 2 1/2" 3.22 0.83 2.32 10 4.18257 08257-2 3" 3.85 0.83 2.92 10 4.88258 08258-9 3 1/2" 3.22 0.83 2.32 10 4.18259 08259-6 4" 3.85 0.83 2.92 10 4.8

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

‹zoleli Zamak Sonlama:‹zoleli bushingler diflli borular›n direk olarakyada rakor ile sonland›r›lmas›nda kullan›l›r.Kablolar›n zedelenmeden çekilmesinisa¤lar, 105º ya kadar güvenle kullan›labilir.‹zolesi sayesinde s›zd›rmazl›k sa¤lar.

Use:Insulated metallic grounding bushings are usedon the end of Rigid and IMC Conduits and otherthreaded connectors to provide a smooth wellrounded bearing surface to protect wires orcables as well as providing a means to connect agrounding conductor.• Nylon Liner Rated 150ºC• 90ºC Dual Rated Feed Through Aluminum Lug

Materials• Zinc Die-Cast

‹zoleli Zamak Sonlama:‹zoleli bushingler diflli borular›n direk olarakyada rakor ile sonland›r›lmas›nda kullan›l›r.Kablolar›n zedelenmeden çekilmesinisa¤lar, 150º ya kadar güvenle kullan›labilir.‹zolesi sayesinde s›zd›rmazl›k sa¤lar. Vidal›aparat› sayesinde topraklaman›n devam›n›sa¤lar.

Bushings w/Lug

Boxed8270 08270-1 1/2" 1.04 0.50 0.54 - 100/500 16.28271 08271-8 3/4" 1.28 0.50 0.74 - 50/250 21.58272 08272-5 1" 1.52 0.59 0.96 - 50/250 27.28273 08273-2 1 1/4" 1.87 0.61 1.27 - 25/125 13.58274 08274-9 1 1/2" 2.16 0.60 1.49 - 25/125 17.98275 08275-6 2" 2.67 0.60 1.95 - 10/50 22.98276 08276-3 2 1/2" 1.52 0.59 0.96 - 10 27.28277 08277-0 3" 1.87 0.61 1.27 - 5/25 13.58278 08278-7 3 1/2" 2.16 0.60 1.49 - 10 17.98279 08279-4 4" 2.67 0.60 1.95 - 10 22.9

Catalog UPC No Trade Nominal Dimensions Pcs Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

StandardsUL 514B CSA C22.2 No. 18NEMA FB-1 NEC Article 345 & 346

Certification

E88878 LR57925

www.afielektrik.comB 21

CONDUIT FITTINGSIMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar›

Page 22: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

Conduit Nipples

Use:Reducing washers are used to reduce the size ofa knock-out in a steel outlet box or metalenclosure. Two reducing washers are required foreach knock-out• Rust Proof• Embossed for Self-CenteringMaterials• Steel

Çelik Redüksiyon :Çelik redüksiyonlar metal kutular ve panolardabulunan ç›k›fl deliklerinde kullan›l›r. Her delikiçin iki adet redüksiyon gereklidir.

Reducing Washers

Boxed8220 08220-6 1/2" 0.93 0.59 0.44 - 100/1000 32.08221 08221-3 3/4" 1.19 0.71 0.50 - 50/500 29.18222 08222-0 1" 1.39 0.84 0.63 - 25/250 20.28223 08223-7 1 1/4" 1.75 0.87 0.63 - 25/250 30.38224 08224-4 1 1/2" 2.13 0.90 0.63 - 25/100 21.08225 08225-1 2" 2.56 1.01 0.72 - 10/40 9.48226 08226-8 2 1/2" 3.28 1.43 1.04 - 10/40 1.38227 08227-5 3" 2.13 0.90 0.63 - 10/40 21.08228 08228-2 3 1/2" 2.56 1.01 0.72 - 10/40 9.48229 08229-9 4" 3.28 1.43 1.04 - 5/20 1.3Boxed w/insulated throat8230 08230-5 1/2" 0.93 0.59 0.44 - 100/1000 32.08231 08231-2 3/4" 1.19 0.71 0.50 - 50/500 29.18232 08232-9 1" 1.39 0.84 0.63 - 25/250 20.28233 08233-6 1 1/4" 1.75 0.87 0.63 - 25/250 30.38234 08234-3 1 1/2" 2.13 0.90 0.63 - 25/100 21.08235 08235-0 2" 2.56 1.01 0.72 - 10/40 9.48236 08236-7 2 1/2" 3.28 1.43 1.04 - 10/40 1.38237 08237-4 3" 2.13 0.90 0.63 - 10/40 21.08238 08238-1 3 1/2" 2.56 1.01 0.72 - 10/40 9.48239 08239-8 4" 3.28 1.43 1.04 - 5/20 1.3

Catalog UPC No Trade Nominal Dimensions Pcs Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Use:Conduit nipples are used to terminate threadedconduit to a knock-out, outlet box or metalenclosure where room is limited, or with a locknutto connect two outlet boxes or metal enclosuresside by side or back to back.Materials• Zinc Die-Cast

Boxed9200 09200-7 3/4"- 1/2" 0.87 1.44 0.04 100/1000 11.99201 09201-4 1"- 1/2" 0.87 1.75 0.04 250/2500 21.99202 09202-1 1"- 3/4" 1.11 1.75 0.04 100/1000 21.99203 09203-8 1 1/4"- 1/2" 0.87 2.18 0.04 50/500 16.99204 09204-5 1 1/4"- 3/4" 1.11 2.185 0.04 100/1000 16.99205 09205-0 1 1/4"- 1" 1.37 2.185 0.04 50/500 11.99206 09206-9 1 1/2"- 1/2" 0.87 2.44 0.04 50/500 26.99207 09207-6 1 1/2"- 3/4" 1.11 2.44 0.03 100/1000 26.99208 09208-3 1 1/2"- 1" 1.37 2.44 0.04 100/1000 39.49209 09209-0 1 1/2"- 1 1/4" 1.72 2.44 0.04 100/1000 39.49210 09210-6 2"- 1/2" 0.87 3.00 0.03 25/250 21.99211 09211-6 2"- 3/4" 1.11 3.00 0.04 25/250 21.99212 09212-0 2"- 1" 1.37 3.00 0.04 25/250 19.49213 09213-7 2"- 1 1/4" 1.72 3.00 0.04 25/250 19.49214 09214-4 2"- 1 1/2" 1.98 3.00 0.04 25/250 16.99215 09215-1 2 1/2"- 1/2" 0.87 3.50 0.04 25/250 21.99216 09216-8 2 1/2"- 3/4" 1.11 3.50 0.04 25/250 21.99217 09217-5 2 1/2"- 1" 1.37 3.50 0.04 25/250 19.49218 09218-0 2 1/2"- 1 1/4" 1.73 3.50 0.04 25/250 16.99219 09219-9 2 1/2"- 1 1/2" 1.98 3.50 0.04 25/250 14.49220 09220-5 2 1/2"- 2" 2.46 3.50 0.04 25/250 11.99221 09221-0 3"- 1/2" 0.88 4.13 0.04 25 11.99222 09222-9 3"- 3/4" 1.11 4.13 0.04 25 21.99223 09223-6 3"- 1" 1.37 4.13 0.04 25 21.99224 09224-3 3"- 1 1/4" 1.73 4.13 0.04 25 16.99225 09225-0 3"- 1 1/2" 1.98 4.13 0.04 25 16.99226 09226-7 3"- 2" 2.47 4.13 0.04 25 11.99227 09227-4 3"- 2 1/2" 2.97 4.13 0.04 25 26.99228 09228-1 3 1/2"- 1/2" 0.88 4.63 0.06 10 26.99229 09229-8 3 1/2"- 3/4" 1.11 4.63 0.06 10 39.49230 09230-3 3 1/2"- 1" 1.37 4.63 0.06 10 39.49231 09231-9 3 1/2" - 1 1/4" 1.73 4.63 0.06 10 21.99232 09232-5 3 1/2" - 1 1/2" 1.98 4.63 0.06 10 21.99233 09233-1 3 1/2" - 2" 2.47 4.63 0.06 10 19.49234 09234-4 3 1/2" - 2 1/2" 2.97 4.63 0.06 10 19.49235 09235-0 3 1/2" - 3" 3.59 4.63 0.06 10 16.99236 09236-6 4" - 1/2" 0.88 5.15 0.06 10 21.99237 09237-2 4" - 3/4" 1.11 5.15 0.06 10 21.99238 09238-8 4" - 1" 1.37 5.15 0.06 10 19.49239 09239-4 4" - 1 1/4" 1.73 5.15 0.06 10 16.99240 09240-9 4" - 1 1/2" 1.98 5.15 0.06 10 14.49241 09241-5 4" - 2" 2.47 5.15 0.06 10 11.99242 09242-1 4" - 2 1/2" 2.97 5.15 0.06 10 16.99243 09243-7 4" - 3" 3.59 5.15 0.06 10 14.49244 09244-0 4" - 3 1/2" 4.13 5.15 0.06 10 11.9

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

ELECTRICAL PRODUCTS

StandardsUL 514B CSA C22.2 No. 18NEMA FB-1 NEC Article 345 & 346

Certification

E88878 LR57925

Zamak Nipel :Döküm nipel diflli borular›n kutu ya dapanolarda sonland›r›lmas›nda kullan›l›r.Kilitleme somunu ile kullan›larak da kutular›nve metal panolar›n yan veya arkayüzeylerinden birlefltirilmelerini sa¤lar.

Certification

E121487 E181788 LR104691

StandardsUL 514B CSA C22.2 No. 18NEMA FB-1 NEC Article 345 & 346

www.afielektrik.com

CONDUIT FITTINGSIMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar›

B 22

Page 23: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

Use:Reducing bushings are used to reduce the entrysize of threaded conduit to allow joining conduitsof two different sizes.Materials• Zinc Die-Cast

Use:Offset nipples are used to provide an offsetconnection between two outlet boxes or metalenclosures.• 3/4" AxisMaterials• Zinc Die-Cast

Boxed8302 08302-8 1/2" 2.42 0.94 0.42 - 10/100 10.58303 08303-5 3/4" 2.40 1.18 0.42 - 10/100 13.28304 08304-2 1" 2.72 1.40 0.60 - 10/100 21.28305 08305-9 1 1/4" 2.81 1.81 0.60 - 5/50 14.78306 08306-6 1 1/2" 3.00 2.00 0.68 - 5/50 20.28307 08307-3 2" 3.15 2.56 0.74 - 2/20 11.4

Catalog UPC No Trade Nominal Dimensions Pcs Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Use:Service entrance ells are used to gain access tothe interior of a raceway for wire pulling,inspection and maintenance.• Listed for Use in Wet LocationMaterials• Die-Cast Aluminium

Offset Nipples

Use:Mogul conduit bodies are used to gain greateraccess to the interior of a raceway for wire pulling,inspection and maintenance where the racewaychanges direction.• Assembled with Cover and Gasket• Meets NEC 6x Requirement• Listed for Use in Wet LocationsMaterials• Die-Cast Aluminum

Mogul Conduit Bodies (Type LB)

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

Boxed500 75005-1 1/2" 3.15 1.19 1.45 38 8.0501 75010-5 3/4" 3.57 1.52 1.77 36 8.0502 75015-0 1" 4.18 1.75 1.97 12 6.0503 75020-4 1 1/4" 5.39 2.19 2.44 12 11.5504 75025-9 1 1/2" 6.10 2.36 2.44 10 10.0505 75030-3 2" 6.61 2.87 2.93 4 5.5503-XL 71035-2 1 1/4" XL 7.83 2.48 2.95 5 6.0505-XL 71040-6 2" XL 9.92 3.13 3.58 5 14.0*XL Denotes Extra Long

Boxed02-51128 51128-9 1 1/4" 9.61 2.51 2.78 - 2 3.802-51129 51129-6 1 1/2" 14.48 3.24 5.31 - 1 4.902-51130 51130-2 2" 14.48 3.24 5.34 - 1 4.5

Catalog UPC No Trade Nominal Dimensions Pcs Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Reducing Bushings

ELECTRICAL PRODUCTS

Zamak Redüksiyon :‹ki farkl› ölçüdeki diflli borular›nbirlefltirilmesinde kullan›l›r.

Boxed8461 08461-2 3/4”-1/2” 0.62 0.80 0.12 - 50/500 20.28462 08462-9 1"-1/2" 0.70 1.00 0.13 - 25/250 27.98463 08463-6 1"-3/4" 0.70 1.00 0.13 - 25/250 32.7

Catalog UPC No Trade Nominal Dimensions Pcs Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

StandardsUL514B CSA C22.2 No. 18NEMA FB-1 NEC Article 345 & 346

Certification

E155411 LR57925

StandardsUL514B CSA C22.2 No. 18NEMA FB-1 NEC Article 345 & 346

Certification

E155411 LR57925

Zamak Kutu Ba¤lant› Nipeli :‹ki farkl› ç›k›fl kutusunun ya da panonunfarkl› seviyelerden birbirlerineba¤lanmas›n› sa¤lar.

StandardsUL514B CSA C22.2 No. 18NEMA FB-1 NEC Article 345 & 346

Certification

E121488 LR57925Alüminyum Döküm Kondulet :Boru tesisat›nda dirsek olarakdönüfllerde, kablo çekmede ve tesisatiçindeki kablolardan ek almaktakullan›l›r. Vidal› kapa¤› sayesinde kabloek yerlerine müdahaleyi kolaylaflt›r›r.

StandardsUL514B CSA C22.2 No. 18NEMA FB-1 NEC Article 345 & 346

Certification

E121488 LR57925

Service Entrance Ells

Alüminyum Döküm Kondulet :Boru tesisatlar›nda kablo çekmede vefarkl› seviyelerden gelen kablolar›nbirlefltirilmesinde kullan›l›r.

www.afielektrik.comB 23

CONDUIT FITTINGSIMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar›

Page 24: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

www.afielektrik.com

ELECTRICAL PRODUCTS

Use:Threaded nipples are used to extend a length ofthreaded Rigid or IMC Conduit according to thepipe size and length desired. May also be used toconnect two steel outlet boxes or metal enclosurestogether.Materials• Galvanized Steel

Rigid Threaded Nipples

Boxed9700 54254-2 1/2" CLOSE 13/16" 25 5.19701 54256-6 1/2" 1 1/2" 13/16" 25 6.99702 54257-3 1/2" 2" 13/16" 25 8.69703 54258-0 1/2" 2 1/2" 13/16" 25 10.49704 54261-0 1/2" 3" 13/16" 25 2.69705 54264-1 1/2" 3 1/2" 13/16" 25 6.49706 54266-5 1/2" 4" 13/16" 15 5.59707 54267-2 1/2" 5" 13/16" 15 6.89708 54268-9 1/2" 5 1/2" 13/16" 25 13.49709 54270-2 1/2" 6" 13/16" 25 4.09710 54272-6 1/2" 8" 13/16" 25 5.79711 54280-1 1/2" 10" 13/16" 25 6.49712 54281-8 1/2" 12" 13/16" 25 7.49713 54284-9 3/4" CLOSE 1 1/16" 10 6.09714 54364-8 3/4" 2" 1 1/16" 6 6.49715 54290-0 3/4" 2 1/2" 1 1/16" 25 9.49716 54365-5 3/4" 3" 1 1/16" 4 5.29717 54300-6 3/4" 3 1/2" 1 1/16" 10 4.99718 54304-4 3/4" 4" 1 1/16" 6 4.79719 54306-8 3/4" 5" 1 1/16" 5 5.59720 54366-2 3/4" 6" 1 1/16" 5 8.59721 54309-9 3/4" 8" 1 1/16" 2 4.89722 54355-6 3/4" 10" 1 1/16" 2 6.59723 54316-7 3/4" 12" 1 1/16" 4 6.49724 54326-6 1" CLOSE 1 5/16" 2 4.09725 54254-2 1" 2" 1 5/16" 25 5.19726 54256-6 1" 2 1/2" 1 5/16" 25 6.99727 54257-3 1" 3" 1 5/16" 25 8.69728 54258-0 1" 3 1/2" 1 5/16" 25 10.49729 54261-0 1" 4" 1 5/16" 25 2.69730 54264-1 1" 5" 1 5/16" 25 6.49731 54266-5 1" 6" 1 5/16" 15 5.59732 54267-2 1" 8" 1 5/16" 15 6.89733 54268-9 1" 10" 1 5/16" 25 13.49734 54270-2 1" 12" 1 5/16" 25 4.09735 54272-6 1 1/4" CLOSE 1 11/16" 25 5.79736 54280-1 1 1/4" 2" 1 11/16" 25 6.49737 54281-8 1 1/4" 2 1/2" 1 11/16" 25 7.49738 54284-9 1 1/4" 3" 1 11/16" 10 6.09739 54364-8 1 1/4" 3 1/2" 1 11/16" 6 6.49740 54290-0 1 1/4" 4" 1 11/16" 25 9.49741 54365-5 1 1/4" 5" 1 11/16" 4 5.29742 54300-6 1 1/4" 6" 1 11/16" 10 4.99743 54304-4 1 1/4" 8" 1 11/16" 6 4.79744 54306-8 1 1/4" 10" 1 11/16" 5 5.59745 54366-2 1 1/4" 12" 1 11/16" 5 8.59746 54309-9 1 1/2" CLOSE 1 7/8" 2 4.89747 54355-6 1 1/2" 2" 1 7/8" 2 6.59748 54316-7 1 1/2" 2 1/2" 1 7/8" 4 6.49749 54326-6 1 1/2" 3" 1 7/8" 2 4.09750 54290-0 1 1/2" 3 1/2" 1 7/8" 25 9.49751 54365-5 1 1/2" 4" 1 7/8" 4 5.29752 54300-6 1 1/2" 5" 1 7/8" 10 4.99753 54304-4 1 1/2" 6" 1 7/8" 6 4.79754 54306-8 1 1/2" 8" 1 7/8" 5 5.59755 54366-2 1 1/2" 10" 1 7/8" 5 8.59756 54309-9 1 1/2" 12" 1 7/8" 2 4.8

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B Qty/Qty Wt.

Galvaniz Çelik Nipel :‹htiyaç duyuldu¤unda IMC ve Rigidborular›n boylar›na ek yapmaktakullan›l›r. Ayr›ca metal kutu vepanolar›n birlefltirilmesindekullan›labilir.

CONDUIT FITTINGSIMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar›

B 24

Page 25: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

ELECTRICAL PRODUCTS

Rigid One Hole Straps

Rigid One Hole Straps

Boxed9340 09340-0 1/2" 2.48 0.62 0.87 - 50/500 11.89341 09341-7 3/4" 2.91 0.69 0.98 - 50/500 14.99342 09342-4 1" 3.36 0.75 1.30 - 25/250 13.29343 09343-1 1 1/4" 4.09 0.88 1.61 - 50 3.79344 09344-8 1 1/2" 4.40 0.94 1.90 - 50 5.39345 09345-5 2" 5.11 1 2.30 - 50 6.7

Catalog UPC No Trade Nominal Dimensions Pcs Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9320 09320-2 1/2" 1.85 0.62 0.90 - 50/500 17.69321 09321-9 3/4" 2.20 0.75 1.13 - 50/500 29.29322 09322-6 1" 2.60 0.88 1.32 - 50/500 42.49323 09323-3 1 1/4" 2.95 0.88 1.64 - 25/250 29.69324 09324-0 1 1/2" 3.62 1.02 1.90 - 25/250 40.59325 09325-7 2" 4.09 1.14 2.32 - 25 6.39316 09326-5 2 1/2" 4.90 1.25 3.00 - 25 11.79317 09327-2 3" 5.53 1.25 3.60 - 25 12.79318 09328-9 3 1/2" 6.18 1.25 4.13 - 25 14.29319 09329-6 4" 6.68 1.25 4.63 - 25 15.7

Catalog UPC No Trade Nominal Dimensions Pcs Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Use:Two hole straps are used for providing support forRigid or IMC Conduit as required by the NationalElectrical Code where higher load bearingsupports are desired.• Click-On TypeÇift Delikli Krofle :IMC ve Rigid borular›nsabitlenmesinde kullan›l›r.Materials• Stamped SteelFinish• Zinc Plated

StandardsUL2239CSA C22.2 No. 18NEC Article 345 & 346

Certification

E 229278 LR57925

Use:One hole straps are used for providing support forRigid or IMC Conduit as required by the NationalElectrical Code.• Click-On TypeTek Delikli Krofle :IMC ve Rigid borular›nsabitlenmesinde kullan›l›r.Materials• Stamped SteelFinish• Zinc Plated

Certification

E 229278 LR57925

www.afielektrik.comB 25

CONDUIT FITTINGSIMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar›

Page 26: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

ELECTRICAL PRODUCTS

Use:Conduit bodies are used to gain access tothe interior of a raceway for wire pulling,inspection and maintenance where theraceway changes direction.• Assembled with Cover and GasketMaterials• Die-Cast Aluminum

Threaded and Set Screw Aluminium Conduit Bodies

Boxed LB TypeD600-CGV 15708-9 1/2" 4.30 1.30 2.40 - 30 3.1D601-CGV 15714-0 3/4" 5.00 1.50 2.60 - 18 4.5D602-CGV 15720-1 1" 5.80 1.80 2.90 - 16 3.1D603-CGV 15726-3 1 1/4" 7.80 2.50 3.70 - 8 2.5D604-CGV 15732-4 1 1/2" 7.80 2.50 3.90 - 8 2.7D605-CGV 15738-6 2" 9.80 3.20 4.70 - 2 4.5Boxed LR TypeD100-CGV 15600-6 1/2" 4.40 2.10 1.60 - 27 1.6D101-CGV 15606-8 3/4" 5.10 2.30 1.90 - 15 2.4D102-CGV 15612-9 1" 5.80 2.50 2.10 - 14 3.1D103-CGV 15618-1 1" 1/4" 7.80 3.40 2.90 - 4 3.1D104-CGV 15624-2 1" 1/2" 7.80 3.40 2.90 - 4 3.0D105-CGV 15630-3 2" 9.90 4.00 3.70 - 2 4.9Boxed LL TypeD200-CGV 15636-5 1/2" 4.40 2.10 1.60 - 27 1.6D201-CGV 15642-6 3/4" 5.10 2.30 1.90 - 15 2.3D202-CGV 15648-8 1" 5.80 2.50 2.10 - 14 3.1D203-CGV 15654-9 1 1/4" 7.80 3.40 2.90 - 4 3.0D204-CGV 15660-0 1 1/2" 7.80 3.40 2.90 - 4 2.7D205-CGV 15666-2 2" 9.90 4.00 3.70 - 2 4.8Boxed T TypeD700-CGV 15744-7 1/2" 4.80 2.10 1.60 - 16 1.7D701-CGV 15750-8 3/4" 5.50 2.30 1.90 - 12 2.4D702-CGV 15756-0 1" 6.20 2.50 2.10 - 5 3.2D703-CGV 15762-1 1 1/4" 8.30 3.40 2.90 - 2 3.3D704-CGV 15768-3 1 1/2" 8.30 3.40 2.90 - 2 2.9D705-CGV 15774-4 2" 10.20 4.00 3.70 - 2 4.9Boxed C TypeD300-CGV 15672-3 1/2" 4.80 1.30 1.60 - 5 1.6D301-CGV 15678-5 3/4" 5.50 1.50 1.90 - 5 2.3D302-CGV 15684-6 1" 6.20 1.80 2.10 - 5 3.0D303-CGV 15690-7 1 1/4" 8.30 2.50 2.90 - 2 2.9D304-CGV 15696-9 1 1/2" 8.30 2.50 2.90 - 2 2.4D305-CGV 15704-1 2" 10.20 3.20 3.70 - 2 4.7Boxed X Type400-CG 72630-8 1/2" 4.75 1.30 1.60 - 5 1.6401-CG 72631-5 3/4" 5.50 1.50 1.90 - 5 2.3402-CG 72632-2 1" 6.20 1.80 2.10 - 5 3.0403-CG 72633-9 1 1/4" 8.30 2.50 2.90 - 2 2.9404-CG 72634-6 1 1/2" 8.30 2.50 2.90 - 2 2.4405-CG 72635-0 2" 10.20 3.20 3.70 - 2 4.7

Catalog UPC No Trade Nominal Dimensions Pcs Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Alüminyum Döküm Konduletler :Boru tesisatlar›nda kablo çekmede,kablolara ek yapmakta, mevcut kablosisteminden ek almakta kullan›l›r.Aç›labilir kapaklar› sayesinde bak›mve kolay müdahale avantajlar› vard›r.Contalar› sayesinde s›zd›rmazl›¤asahiptirler.

Certification

E121488 LR57925

StandardsUL 514B CSA C22.2 No. 18NEMA FB-1 NEC Article 345 & 346

LB Type

LR Type

LL Type

T Type

C Type

X Type

B 26

www.afielektrik.com

CONDUIT FITTINGSIMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar›

Page 27: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

www.afielektrik.comB 27

Use:Conduit bodies are used to gain access to theinterior of a raceway for wire pulling, inspectionand maintenance where the raceway changesdirection.• Assembled with Cover and GasketMaterials• Malleable Iron

Threaded Malleable Iron Conduit Bodies

Sfero Döküm Konduletler :Boru tesisatlar›nda kablo çekmede,kablolara ek yapmakta, mevcut kablosisteminden ek almakta kullan›l›r.Aç›labilir kapaklar› sayesinde bak›mve kolay müdahale avantajlar› vard›r.Contalar› sayesinde s›zd›rmazl›¤asahiptirler.

ELECTRICAL PRODUCTS

Certification

E121488 LR57925

StandardsUL 514B CSA C22.2 No. 18NEMA FB-1 NEC Article 345 & 346

Boxed LB TypeM600 15800-0 1/2" 4.30 1.30 2.40 - 10 7.1M601 15801-7 3/4" 5.00 1.50 2.60 - 10 9.7M602 15802-4 1" 5.80 1.80 2.90 - 10 14.3M603 15803-0 1 1/4" 7.80 2.50 3.70 - 10 28.7M604 15804-8 1 1/2" 7.80 2.50 3.90 - 10 33.2M605 15805-0 2" 9.80 3.20 4.70 - 5 26.7Boxed LR TypeM100 15830-6 1/2" 4.40 2.10 1.60 - 10 7.1M101 15831-2 3/4" 5.10 2.30 1.90 - 10 10.0M102 15832-8 1" 5.80 2.50 2.10 - 10 15.7M103 15833-4 1" 1/4" 7.80 3.40 2.90 - 10 33.2M104 15834-7 1" 1/2" 7.80 3.40 2.90 - 10 34.5M105 15835-3 2" 9.90 4.00 3.70 - 5 31.3Boxed LL TypeM200 15820-8 1/2" 4.40 2.10 1.60 - 10 7.6M201 15821-0 3/4" 5.10 2.30 1.90 - 10 9.5M202 15822-2 1" 5.80 2.50 2.10 - 10 13.8M203 15823-9 1 1/4" 7.80 3.40 2.90 - 10 30.9M204 15824-6 1 1/2" 7.80 3.40 2.90 - 10 33.2M205 15825-3 2" 9.90 4.00 3.70 - 5 24.9Boxed T TypeM700 15840-2 1/2" 4.80 2.10 1.60 - 10 11.1M701 15841-8 3/4" 5.50 2.30 1.90 - 10 13.7M702 15842-4 1" 6.20 2.50 2.10 - 10 19.6M703 15843-0 1 1/4" 8.30 3.40 2.90 - 10 33.2M704 15844-3 1 1/2" 8.30 3.40 2.90 - 10 36.8M705 15845-9 2" 10.20 4.00 3.70 - 2 13.3Boxed C TypeM300 15810-9 1/2" 4.80 1.30 1.60 - 10 9.8M301 15811-6 3/4" 5.50 1.50 1.90 - 10 11.8M302 15812-3 1" 6.20 1.80 2.10 - 10 17.0M303 15813-0 1 1/4" 8.30 2.50 2.90 - 10 30.9M304 15814-7 1 1/2" 8.30 2.50 2.90 - 10 36.8M305 15815-4 2" 10.20 3.20 3.70 - 5 27.6Boxed X Type410-CG 72636-0 1/2" 4.75 1.30 1.60 - 10 13.9411-CG 72637-7 3/4" 5.50 1.50 1.90 - 10 17.2412-CG 72638-4 1" 6.20 1.80 2.10 - 10 24.7413-CG 72639-1 1 1/4" 8.30 2.50 2.90 - 10 41.6414-CG 72640-7 1 1/2" 8.30 2.50 2.90 - 10 46.3415-CG 72641-4 2" 10.20 3.20 3.70 - 2 16.7

Catalog UPC No Trade Nominal Dimensions Pcs Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

*2 1/2" - 4" Available upon request except "X" type.

LB Type

LR Type

LL Type

T Type

C Type

X Type

CONDUIT FITTINGSIMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar›

Page 28: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

B 28

www.afielektrik.com

ELECTRICAL PRODUCTS

Use:90° liquid-tight connectors are used to terminate andseal Liquid-Tight Flexible Nonmetallic Type B Conduitsat 90° angles to either an oil-tight, liquid-tight or rain-tightbox or enclosure. Connectors can be used with taperedthread female entry or unthreaded knock-out using theprovided sealing washer and locknut.• Resists Salt Water, Weak Acids, Gasoline,Alcohol, Oil, Grease and Common Solvents• No Disassembly Required• ReusableMaterials• Nylon

Use:Straight liquid-tight connectors are used to terminate andseal Liquid -Tight Flexible Nonmetallic Type B Conduit toeither an oil-tight, liquid-tight or rain-tight box or enclosure.Connectors can be used with tapered thread female entryor unthreaded knock-out using the provided sealing washerand locknut.• Resists Salt Water, Weak Acids, Gasoline, Alcohol,Oil, Grease and Common Solvents• No Disassembly Required• Reusable

Materials• Nylon

Straight Liquid-Tight Connectors

90° Liquid-Tight Connectors

Boxed7106 07106-4 3/8” 1.44 2.31 20 2.07100 07100-2 1/2” 1.63 2.50 25/100 10.07101 07101-9 3/4” 1.94 2.81 20 2.57102 07102-6 1” 2.25 3.44 10 2.17103 07103-3 1 1/4” 2.69 4.25 5/50 12.07104 07104-0 1 1/2” 3.13 4.69 5/20 14.07105 07105-0 2” 3.63 5.31 2/20 9.0

A B

Nominal DimensionsCatalogNumber

UPC No0-87115

TradeSize

Ctn/CaseQty/Qty

CaseWt.

Boxed7116 07116-3 3/8” 2.00 1.40 20 2.27110 07110-1 1/2” 2.00 1.40 20 2.27111 07111-8 3/4” 2.15 1.68 20 2.87112 07112-5 1” 2.25 2.00 10 2.57113 07113-2 1 1/4” 1.26 1.20 2/20 8.07114 07114-9 1 1/2” 1.43 1.46 2/20 10.07115 07115-6 2” 1.85 1.78 1/10 9.0

A B

Nominal DimensionsCatalogNumber

UPC No0-87115

TradeSize

Ctn/CaseQty/Qty

CaseWt.

CONDUIT FITTINGSLiquidtight Conduit Fittings/S›v› S›zd›rmaz Spiral Boru Aksesuarlar›

PVC Kapl› Çelik Spiral BoruSonland›rma Rakoru (Metal olmayan) :S›v› s›zd›rmaz PVC kapl› çelik spiral borular›nkutu, buat, pano vb. girifllerindesonland›r›lmas› ve sabitlenmesi amac›ylakullan›l›r. S›v› s›zd›rmaz özelli¤i vard›r. Contas›ve kilitleme somunu ile birlikte sat›l›r.

PVC Kapl› Çelik Spiral BoruSonland›rma Rakoru (Metal olmayan) :S›v› s›zd›rmaz PVC kapl› çelik spiral borular›nkutu, buat, pano vb. girifllerinde 90˚ ilesonland›r›lmas› ve sabitlenmesi amac›ylakullan›l›r. S›v› s›zd›rmaz özelli¤i vard›r. Contas›ve kilitleme somunu ile birlikte sat›l›r.

Page 29: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

www.afielektrik.comB 29

ELECTRICAL PRODUCTS

* UL Listed liquidtight flexible metalconduit fittings are suitable for use inthe following hazardous locationsunder NEC 501-4(b), 502-4(a)(2);Class I, Div. 2; Class II, Div. 1 and 2;and Class III, Div. 1 and 2.

Straight Liquid-Tight Connectors(Malleable Iron)

Use:Straight liquid-tight connectors are used to terminateand seal Liquid-Tight Flexible Metal andLiquid-Tight Flexible Nonmetallic Type B Conduitsto either an oil-tight, liquid-tight or rain-tight box orenclosure. Connectors can be used with taperedthread female entry or unthreaded knock-out usingthe provided sealing washer and locknut.• Furnished with Sealing Ring• Suitable for Grounding (up to 111/4")

Use:Straight liquid-tight connectors are used to terminateand seal Liquid-Tight Flexible Metal andLiquid-Tight Flexible Nonmetallic Type B Conduitsto either an oil-tight, liquid-tight or rain-tight box orenclosure. Connectors can be used with taperedthread female entry or unthreaded knock-out usingthe provided sealing washer and locknut.• Tapered threaded male hub - NPT• Compact, slim diameter• Steel locknut• Liquidtight/Raintight/Oiltight• Suitable for wet locations• Long ferrule prevents pullout& tight bend conduit pop out

Materials• Malleable Iron

Boxed8248 08248-0 3/8" 2.80 2.95 0.66 25/100 16.88310 08310-4 1/2" 1.50 1.22 0.50 25/100 13.98311 08311-1 3/4" 1.60 1.48 0.50 10/100 20.18312 08312-8 1" 2.00 1.75 0.68 5/25 8.38313 08313-5 1 1/4" 2.24 2.23 0.68 5/25 12.28314 08314-2 1 1/2" 2.50 2.48 0.66 2/10 5.98315 08315-9 2" 2.80 2.95 0.66 2/10 7.18316 08316-6 2 1/2" 2.00 1.75 0.68 1 2.08317 08317-3 3" 2.24 2.23 0.68 1 2.48318 08318-0 3 1/2" 2.50 2.48 0.66 1 3.28319 08319-7 4" 2.80 2.95 0.66 1 3.7Boxed w/ insulated throat8249 08249-7 3/8" 2.80 2.95 0.66 25/100 16.88320 08320-3 1/2" 1.50 1.22 0.50 25/100 13.98321 08321-0 3/4" 1.60 1.48 0.50 10/100 20.18322 08322-7 1" 2.00 1.75 0.68 5/25 8.38323 08323-4 1 1/4" 2.24 2.23 0.68 5/25 12.28324 08324-1 1 1/2" 2.50 2.48 0.66 2/10 5.98325 08325-8 2" 2.80 2.95 0.66 2/10 7.18326 08326-5 2 1/2" 2.00 1.75 0.68 1 2.08327 08327-2 3" 2.24 2.23 0.68 1 2.48328 08328-9 3 1/2" 2.50 2.48 0.66 1 3.28329 08329-6 4" 2.80 2.95 0.66 1 3.7

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

Boxed9376 09376-9 3/8" 1 1/8" 1/2" 1 1/8" 25/100 15.49370 09370-7 1/2" 1 1/4" 1/2" 1 1/4" 25/100 17.69371 09371-4 3/4" 1 1/4" 1/2" 1 9/16" 10/100 28.79372 09372-1 1" 1 7/16" 5/8" 1 13/16" 5/50 19.99373 09373-8 1 1/4" 1 1/2" 11/16" 2 1/4" 5/50 27.69375 09375-0 2" 1 3/4" 3/4" 3" 2/20 19.89427 19427-8 2 1/2" 2 3/16" 1" 4" 1 3.69428 19428-5 3" 2 1/2" 1 1/8" 4 3/16" 1 4.69429 09429-0 3 1/2" 2 5/8" 1 3/16" 5 1/4" 1 6.79430 09430-8 4" 2 3/4" 1 1/4" 5 3/4" 1 7.99374 09374-5 1 1/2" 1 5/8" 3/4" 2 7/16" 2/20 14.1Boxed w/ insulated throat9386 09386-8 3/8" 1 1/8" 9/16" 1 1/8" 25/100 15.49380 09380-6 1/2" 1 1/4" 9/16" 1 1/4" 25/100 17.69381 09381-3 3/4" 1 1/4" 9/16" 1 9/16" 10/100 28.79382 09382-0 1" 1 7/16" 11/16" 1 13/16" 5/50 19.99383 09383-7 1 1/4" 1 1/2" 3/4" 2 1/4" 5/50 27.69384 09384-4 1 1/2" 1 5/8" 1 3/16" 2 7/16" 2/20 14.19385 09385-1 2" 1 3/4" 1 3/16" 3" 2/20 19.89431 09431-5 2 1/2" 2 3/16" 1 1/16" 4" 1 3.69432 09432-0 3" 2 1/2" 1 3/16" 4 3/16" 1 4.69433 09433-9 3 1/2" 2 5/8" 1 1/4" 5 1/4" 1 6.79434 09434-6 4" 2 3/4" 1 5/16" 5 3/4" 1 7.9

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

Straight Liquid-Tight Connectors

StandardsUL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 351

Certification

StandardsUL 514BNEMA FB-1

E207875

CONDUIT FITTINGSLiquidtight Conduit Fittings/S›v› S›zd›rmaz Spiral Boru Aksesuarlar›

PVC Kapl› Çelik Spiral BoruZamak Sonland›rma Rakoru :S›v› s›zd›rmaz PVC kapl› çelik spiral borular›nkutu, buat, pano vb. girifllerde sonland›r›l›p,sabitlenmesi amac›yla kullan›l›r. Ya¤murun,ya¤›n ve s›v›lar›n tesisat›n içerisine girmesiniönler. Kilitleme somunu ve tüm aksesuarlar›ile birlikte sat›l›r.

Materials:• Zinc Die-Cast

PVC Kapl› Çelik Spiral BoruDöküm Sonland›rma Rakoru :S›v› s›zd›rmaz PVC kapl› çelik spiral borular›nkutu, buat, pano vb. girifllerde sonland›r›l›p,sabitlenmesi amac›yla kullan›l›r. Ya¤murun,ya¤›n ve s›v›lar›n tesisat›n içerisine girmesiniönler. Kilitleme somunu ve tüm aksesuarlar›ile birlikte sat›l›r.

Certification:

E155411 LR57925

Page 30: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

B 30

www.afielektrik.com

ELECTRICAL PRODUCTS

Boxed8246 08246-6 3/8” 1.50 1.21 0.50 10/50 11.98380 08280-0 1/2” 1.52 1.21 0.50 10/50 11.58381 08281-7 3/4” 1.60 1.37 0.53 10/50 27.58382 08282-4 1” 2.00 1.73 0.69 5/25 11.58383 08283-1 1 1/4” 2.24 2.13 0.67 5/25 19.88384 08284-8 1 1/2” 2.50 2.44 0.67 2/10 10.38385 08285-5 2” 2.80 1.75 0.67 2/10 13.08386 08286-2 2 1/2” 2.00 1.75 0.68 1 3.68387 08287-9 3” 2.24 2.23 0.68 1 5.68388 08288-6 3 1/2” 2.50 2.48 0.66 1 2.78389 08289-3 4” 2.80 2.95 0.66 1 3.3Boxed w/ insulated throat8247 08247-3 3/8” 2.80 2.95 0.66 10/50 11.98390 08290-9 1/2” 1.50 1.22 0.50 10/50 11.58391 08291-6 3/4” 1.60 1.48 0.50 10/50 27.58392 08292-3 1” 2.00 1.75 0.68 5/25 11.58393 08293-0 1 1/4” 2.24 2.23 0.68 5/25 19.88394 08294-7 1 1/2” 2.50 2.48 0.66 2/10 10.38395 08295-4 2” 2.80 2.95 0.66 2/10 13.08396 08296-1 2 1/2” 2.00 1.75 0.68 1 3.68397 08297-8 3” 2.24 2.23 0.68 1 5.68398 08298-5 3 1/2” 2.50 2.48 0.66 1 2.78399 08299-2 4” 2.80 2.95 0.66 1 3.3

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

Boxed9416 09376-9 3/8” 1 5/16" 1/2" 1 1/8" 10/100 25.49410 09370-7 1/2” 1 7/16" 1/2" 1 1/4" 10/100 28.99411 09371-4 3/4” 1 5/8" 1/2" 1 9/16" 10/100 44.19412 09372-1 1” 2 5/16" 5/8" 1 13/16" 5/50 37.39413 09373-8 1 1/4" 2 3/8" 11/16" 2 1/4" 2/20 19.29414 09375-0 1 1/2" 3 11/16" 3/4" 27/16" 2/20 24.39415 19427-8 2" 3 3/16" 3/4" 3" 1/10 17.69478 19428-5 2 1/2" 8 5/16" 1" 4" 1 8.49479 09429-0 3" 9 3/16" 1 1/8" 4 3/16" 1 12.49480 09430-8 3 1/2" 11 3/16" 1 3/16" 5 1/4" 1 19.09481 09374-5 4" 13" 1 1/4" 5 3/4" 1 23.8Boxed w/ insulated throat9426 09416-2 3/8" 1 1/8" 9/16" 1 1/8" 10/100 25.79420 09410-0 1/2" 1 1/4" 9/16" 1 1/4" 10/100 29.29321 09411-7 3/4" 1 1/4" 9/16" 1 9/16" 10/100 44.69322 09412-4 1" 1 7/16" 5/8" 1 13/16" 5/50 37.79323 09413-1 1 1/4" 1 1/2" 3/4" 2 1/4" 2/20 5.69324 09414-0 1 1/2" 1 5/8" 1 3/16" 2 7/16" 2/20 2.79325 09415-5 2" 1 3/4" 1 3/16" 3" 1/10 3.39482 09478-0 2 1/2" 2 3/16" 1 1/16" 4" 1 3.69483 09479-7 3" 2 1/2" 1 3/16" 4 3/16" 1 5.69484 09480-3 3 1/2" 2 5/8" 1 1/4" 5 1/4" 1 2.79485 09481-0 4" 2 3/4" 1 5/16" 5 3/4" 1 3.3

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

Use:90° liquid-tight connectors are used to terminateand seal Liquid-Tight Flexible Metal and Liquid-Tight Flexible Nonmetallic Type B Conduits at 90°angles to either an oil-tight, liquid-tight or rain-tightbox or enclosure. Connectors can be used withtapered thread female entry or unthreaded knockoutusing the provided sealing washer and locknut.• UL Listed Locknut• Furnished with Sealing Ring• Suitable for Grounding (up to 111/4”)Materials• Zinc Die-CastCertification

E155411 LR57925

Use:90° liquid-tight connectors are used to terminateand seal Liquid-Tight Flexible Metal and Liquid-Tight Flexible Nonmetallic Type B Conduits at 90°angles to either an oil-tight, liquid-tight or rain-tightbox or enclosure. Connectors can be used withtapered thread female entry or unthreaded knockoutusing the provided sealing washer and locknut.• UL Listed Locknut• Furnished with Sealing Ring• Suitable for Grounding (up to 111/4")Materials• Malleable Iron

90° Liquid-Tight Connectors (Malleable Iron)

90° Liquid-Tight Connectors

StandardsUL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 35190° Liquid-Tight Connectors LIQUID TIGHTCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Certification

StandardsUL 514BNEMA FB-1

E207875

PVC Kapl› Çelik Spiral BoruZamak 90º Sonland›rma Rakoru :S›v› s›zd›rmaz PVC kapl› çelik spiral borular›nkutu, buat, pano vb. girifllerde 90˚ ilesonland›r›lmas› ve sabitlenmesi amac›ylakullan›l›r. S›v› s›zd›rmaz özelli¤i vard›. Contas›ve kilitleme somunu ile birlikte sat›l›r.

PVC Kapl› Çelik Spiral BoruDöküm 90º Sonland›rma Rakoru :S›v› s›zd›rmaz PVC kapl› çelik spiral borular›nkutu, buat, pano vb. girifllerinde 90˚ ilesonland›r›lmas› ve sabitlenmesi amac›ylakullan›l›r. S›v› s›zd›rmaz özelli¤i vard›. Contas›ve kilitleme somunu ile birlikte sat›l›r.

CONDUIT FITTINGSLiquidtight Conduit Fittings/S›v› S›zd›rmaz Spiral Boru Aksesuarlar›

Page 31: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

www.afielektrik.comB 31

CONDUIT FITTINGSFlexible Steel Conduit Fittings/Galvaniz Çelik Spiral Boru Aksesuarlar›

ELECTRICAL PRODUCTS

Use:Screw-in type couplings are used to join lengths ofFlexible Metal Conduit.Zamak Spiral Çelik Boru Ek Mufu:Çelik spiral borular›n birbirine eklenmesinde kullan›l›r.Materials:• Zinc Die-Cast

Certification:E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18NEMA FB-1 NEC Article 3508

Screw-In Greenfield Couplings

Boxed8370 08370-8 1/2” 1.79 0.97 0.20 - 50/500 23.158350 08350-0 3/4” 2.00 1.21 0.22 - 25/250 19.84

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Use:Screw-in type connectors are usedto terminate Flexible Metal Conduitto a knock-out in a dry location boxor enclosure, where minimumspacing is desired between theconduits.

Zamak Spiral Çelik Boru Rakoru:Çelik spiral borular›n pano, buat,armatür ve benzeri yerlerdesonland›r›lmas›nda kullan›l›r.

Materials:• Zinc Die-Cast

Certification:E155411 LR57925

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 350

Screw-In Greenfield Connectors

TradeSize For Cable Sizes3/8" For Regular Wall Steel or Aluminum Flexible Metal Conduit.1/2" For Regular Wall Steel or Aluminum Flexible Metal Conduit.3/4" For Regular or Reduced Wall Steel or Aluminum Flexible Metal Conduit.1"-2” For Regular Wall Steel or Aluminum Flexible Metal Conduit.

Boxed8356 08356-2 3/8" 1.30 0.92 0.41 - 50/500 24.148350 08350-0 1/2" 1.37 0.92 0.41 - 50/500 26.248351 08351-7 3/4" 1.63 1.12 0.43 - 25/250 20.128352 08352-4 1" 1.92 1.35 0.56 - 25/250 39.578353 08353-1 1 1/4" 2.12 1.75 0.61 - 10/100 22.518354 08354-8 1 1/2" 2.32 2.1 0.62 - 10/40 14.218355 08355-5 2" 2.55 2.66 0.75 - 10/40 22.13Boxed w/ Insulated Throat8360 08360-9 1/2" 1.37 0.92 0.41 - 50/500 26.248361 08361-6 3/4" 1.63 1.12 0.43 - 25/250 20.128362 08362-3 1" 1.92 1.35 0.56 - 25/250 39.578363 08363-0 1 1/4" 2.12 1.75 0.61 - 10/100 22.518364 08364-7 1 1/2" 2.32 2.1 0.62 - 10/40 14.218365 08365-4 2" 2.55 2.66 0.75 - 10/40 22.13

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Page 32: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

B 32

www.afielektrik.com

Boxed8200 08200-8 3/8" 1.32 1.30 0.39 - 50/500 44.88180 08180-3 1/2" 1.64 1.63 0.43 - 25/250 31.18181 08181-0 3/4" 1.77 1.89 0.43 - 10/100 18.58182 08182-7 1" 2.13 2.30 0.53 - 10 3.28183 08183-0 1 1/4" 3.00 2.69 0.59 - 10 4.88184 08184-7 1 1/2" 4.80 3.59 0.70 - 4 4.48185 08185-4 2" 4.80 3.59 0.70 - 4 4.68186 08186-5 2 1/2" 4.80 4.45 0.85 - 5 12.98187 08187-2 3" 5.58 5.00 0.85 - 1 3.58188 08188-9 3 1/2" 6.41 5.51 1.02 - 1 6.38189 08189-6 4" 7.22 6.10 1.06 - 1 7.4

Boxed w/ insulated throat8201 08201-5 3/8" 1.32 1.30 0.39 - 50/500 44.88190 08190-2 1/2" 1.64 1.63 0.43 - 25/250 31.18191 08191-9 3/4" 1.77 1.89 0.43 - 10/100 18.58192 08192-6 1" 2.13 2.30 0.53 - 10 3.28193 08193-3 1 1/4" 3.00 2.69 0.59 - 10 4.88194 08194-0 1 1/2" 4.80 3.59 0.70 - 4 4.48195 08195-7 2" 4.80 3.59 0.70 - 4 4.68196 08196-4 2 1/2" 4.80 4.45 0.85 - 5 12.98197 08197-1 3" 5.58 5.00 0.85 - 1 3.58198 08198-8 3 1/2" 6.41 5.51 1.02 - 1 6.38199 08199-5 4" 7.22 6.10 1.06 - 1 7.4

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9530 09530-5 1/2" 1.64 1.63 0.43 - 25/250 31.19531 09531-2 3/4" 1.77 1.89 0.43 - 10/100 18.59532 09532-9 1" 2.13 2.30 0.53 - 10 3.29533 09533-6 1 1/4" 3.00 2.69 0.59 - 10 4.89534 09534-3 1 1/2" 4.80 3.59 0.70 - 4 4.49535 09535-0 2" 4.80 3.59 0.70 - 4 4.69536 09536-7 2 1/2" 4.80 4.45 0.85 - 5 12.99537 09537-4 3" 5.58 5.00 0.85 - 1 3.59538 09538-1 3 1/2" 6.41 5.51 1.02 - 1 6.39539 09539-8 4" 7.22 6.10 1.06 - 1 7.4

Boxed w/ insulated throat9530I 99530-8 1/2" 1.64 1.63 0.43 - 25/250 31.19531I 99531-5 3/4" 1.77 1.89 0.43 - 10/100 18.59532I 99532-2 1" 2.13 2.30 0.53 - 10 3.29533I 99533-9 1 1/4" 3.00 2.69 0.59 - 10 4.89534I 99534-6 1 1/2" 4.80 3.59 0.70 - 4 4.49535I 99535-3 2" 4.80 3.59 0.70 - 4 4.69536I 99536-0 2 1/2" 4.80 4.45 0.85 - 5 12.99537I 99537-7 3" 5.58 5.00 0.85 - 1 3.59538I 99538-4 3 1/2" 6.41 5.51 1.02 - 1 6.39539I 99539-1 4" 7.22 6.10 1.06 - 1 7.4

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Use:90° connectors are used to make a 90° terminationof Armored Cable, Metal Clad Cable or FlexibleMetal Conduit to a knock-out or unthreaded sliphole in a dry location box or enclosure.90º Dövme Demir Spiral Çelik Boru Rakoru:Çelik spiral borular›n ve z›rhl› kablolar›n buat,pano,armatür ve benzeri yerlerde 90º girifl ilesonland›r›lmas›nda kullan›l›r.

• Squeeze Type

Materials:• Malleable Iron

Certification: E155411 LR57925

90° Angle Connectors

90° Angle Connectors (Malleable Iron)

TradeSize For Cable Sizes3/8" For regular Wall Steel or Aluminum Flexible Metal Conduit. For 14-2 through 10-3

Steel or Aluminum Armored Cable. For 14-2 through 10-3 Interlocking Steel or Aluminum Metal clad Cable.1/2" For Regular Wall Steel or Aluminum Flexible Metal Conduit. For 8-2 through 8-3 Steel or Aluminum Armored

Cable. For 8-2 through 8-3 interlocking Steel or Aluminum Metal clad Cable.3/4" For regular or Reduced Wall Steel or Aluminum Flexible Metal Conduit.

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Articles 350, 333 & 334

Use:90° connectors are used to make a 90° terminationof Armored Cable, Metal Clad Cable or FlexibleMetal Conduit to a knock-out or unthreaded sliphole in a dry location box or enclosure.90º Zamak Spiral Çelik Boru Rakoru:Çelik spiral borular›n ve z›rhl› kablolar›n buat,pano,armatür ve benzeri yerlerde 90º girifl ilesonland›r›lmas›nda kullan›l›r.

• Squeeze Type

Materials:• Zinc Die-Cast

Certification: E155411 LR57925

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Articles 350, 333 & 334

CONDUIT FITTINGSFlexible Steel Conduit Fittings/Galvaniz Çelik Spiral Boru Aksesuarlar›

ELECTRICAL PRODUCTS

Page 33: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

www.afielektrik.comB 33

ELECTRICAL PRODUCTS

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8375 08375-3 3/8" 1.09 0.5 0.62 - 50/500 32.08380 08380-7 1/2" 1.50 0.5 0.99 - 25/250 21.68381 08381-4 3/4" 1.59 0.5 1.18 - 25/250 33.78382 08382-1 1" 1.75 0.5 1.45 - 10/100 21.08383 08383-8 1 1/4" 1.90 0.6 1.73 - 10/100 28.08384 08384-5 1 1/2" 2.00 0.6 2.00 - 5/50 18.08385 08385-2 2" 2.10 0.6 2.55 - 10/40 18.48386 08386-9 2 1/2" 1.75 0.5 1.45 - 5 4.58387 08387-6 3" 1.90 0.6 1.73 - 1/5 12.78388 08388-3 3 1/2" 2.00 0.6 2.00 - 1 1.78389 08389-0 4" 2.10 0.6 2.55 - 1 2.1

Boxed w/ insulated throat8390 08390-6 1/2" 1.50 0.5 0.99 - 25/250 21.68391 08391-3 3/4" 1.59 0.5 1.18 - 25/250 33.78392 08392-0 1" 1.75 0.5 1.45 - 10/100 21.08393 08393-7 1 1/4" 1.90 0.6 1.73 - 10/100 28.08394 08394-4 1 1/2" 2.00 0.6 2.00 - 5/50 18.08395 08395-1 2" 2.10 0.6 2.55 - 10/40 18.48396 08396-8 2 1/2" 1.75 0.5 1.45 - 5 9.08397 08397-5 3" 1.90 0.6 1.73 - 1/5 12.78398 08398-2 3 1/2" 2.00 0.6 2.00 - 1 1.78399 08399-9 4" 2.10 0.6 2.55 - 1 2.1

TradeSize For Cable Sizes3/8" For Regular or Reduced Wall Steel Flexible Metal Conduit. For 12-2 through 10-3 Steel or Aluminum

aromoredcable. For 12-2 through 10-3 Interlocking Steel or Aluminum Metal Clad Cable.

3/4" For Regular or Reduced Wall Steel or Aluminum Flexible Metal Conduit.1/2" For Regular or Reduced Wall Steel Flexible Metal Conduit. For 6-3 Steel or Aluminum Aromored

Cable.For 6-3 Interlocking Steel or Aluminum Metal Clad Cable.

Certification: E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18NEMA FB-1 NEC Article 350

Certification: E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18NEMA FB-1 NEC Article 350

CONDUIT FITTINGSFlexible Steel Conduit Fittings/Galvaniz Çelik Spiral Boru Aksesuarlar›

Zamak Spiral Çelik Boru Rakoru :Çelik spiral borular›n ve z›rhl› kablolar›n kutu vepanolara ba¤lant›s›nda kullan›l›r.

Squeeze Connectors

Squeeze Connectors (Malleable Iron) Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9580 09580-0 1/2" 1.50 0.5 0.99 - 25/125 16.69581 09581-7 3/4" 1.59 0.5 1.18 - 20/100 16.79582 09582-4 1" 1.75 0.5 1.45 - 10/50 13.09583 09583-1 1 1/4" 1.90 0.6 1.73 - 10/50 20.09584 09584-8 1 1/2" 2.00 0.6 2.00 - 5/25 15.89585 09585-5 2" 2.10 0.6 2.55 - 20 21.49586 09586-2 2 1/2" 1.75 0.5 2.00 - 5 8.69587 09587-9 3" 1.90 0.6 1.73 - 5 10.19588 09588-6 3 1/2" 2.00 0.6 2.00 - 1 4.49589 09589-3 4" 2.10 0.6 2.55 - 1 6.6

Boxed w/ insulated throat9580I 99580-3 1/2" 1.50 0.5 0.99 - 25/125 16.89581I 99581-0 3/4" 1.59 0.5 1.18 - 20/100 16.99582I 99582-7 1" 1.75 0.5 1.45 - 10/50 13.19583I 99583-4 1 1/4" 1.90 0.6 1.73 - 10/50 20.19584I 99584-1 1 1/2" 2.00 0.6 2.00 - 5/25 15.99585I 99585-8 2" 2.10 0.6 2.55 - 20 21.69586I 99586-5 2 1/2" 1.75 0.5 1.45 - 5 8.79587I 99587-2 3" 1.90 0.6 1.73 - 5 10.29588I 99588-9 3 1/2" 2.00 0.6 2.00 - 1 4.59589I 99589-6 4" 2.10 0.6 2.55 - 1 6.7

Use:Squeeze connectors are used to terminate FlexibleMetal Conduit to a knock-out in a dry location boxor enclosure.• Squeeze Type

Materials:• Zinc Die-Cast

Use:Squeeze connectors are used to terminate FlexibleMetal Conduit to a knock-out in a dry location boxor enclosure.

• Squeeze Type

Materials:• Malleable Iron

Döküm Spiral Çelik Boru Rakoru :Çelik spiral borular›n kutu ve panolaraba¤lant›s›nda kullan›l›r.

Page 34: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

B 34

www.afielektrik.com

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

Boxed8205 08205-3 3/8" 0.78 0.63 0.36 100/1000 46.7

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

Boxed8245 08245-7 1/2" 0.95 1.50 0.40 10/120 15.78241 08241-5 3/4” 1.15 1.55 0.49 5/60 11.1

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

Boxed8244 08244-2 3/8" 0.80 1.17 0.35 100/1000 50.1

ELECTRICAL PRODUCTS

Certification:

E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18NEMA FB-1 NEC Articles 333

Certification:

E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18NEMA FB-1 NEC Articles 333

Certification:

E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18NEMA FB-1 NEC Articles 333

CONDUIT FITTINGSFlexible Steel Conduit Fittings/Galvaniz Çelik Spiral Boru Aksesuarlar›

Combination Connectors

Set Screw Flex Connectors

TradeSize For Cable Sizes3/8" For 14-2 (nominal OD .460”) through 10-2 (nominal OD .598”) Steel Armored Cable.

For 14-2 (nominal OD .469”) through 10-3 (nominal OD .600”) Steel InterlockingMetal Clad Cable.

TradeSize For Cable Sizes3/8" For Regular Wall Steel or Aluminum Flexible Metal Conduit.

For 14-2 through 10-2 Steel or Aluminum Armored Cable.For 14-2 (nominal OD .600”) Steel Interlocking Metal Clad Cable.Aluminum Interlocking Metal Clad Cable; 14-2 (nominal OD .469”)

Use:BX connectors are used to terminate steel ArmoredCable to a 1/2” knock-out in a dry location box orenclosure.• End Stopped

Materials:• Zinc Die-Cast

BX Connectors

Zamak Z›rhl› Kablo Kutu Ba¤lant› Rakoru :Z›rhl› kablolar›n kutu ve panolara ba¤lant›s›ndakullan›l›r.

Use:Set screw flex connectors are used to terminate RegularWall Steel or Aluminum Flexible Metal Conduit to aKnock-out in a dry location box or enclosure.• Set Screw

Materials:• Zinc Die-Cast

Zamak Kutu Ba¤lant› Rakoru :Metal borular›n ve alüminyum spiral borular›nkutu ve panolara ba¤lant›s›nda kullan›l›r.

Use:Clamp type connectors are used to terminateArmored cable, Metal Clad Cable or FlexibleMetal Conduit to a 1/2” knock-out in a dry box orenclosure.• Metal Hub Threads NPS• End Stopped

Zamak Kutu Ba¤lant› Aparat› :Spiral metal borular›n, z›rhl› kablolar›n kutu vepanolara 1/2” delik çap›nda ba¤lant›s›ndakullan›l›r.

Materials:• Zinc Die-Cast

Page 35: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

www.afielektrik.comB 35

TradeSize For Cable Sizes3/8" For 14-2 (nominal OD .465") through 10-3 (nominal OD .500") Steel Armored Cable;

For 14-2 (nominal OD .480") through 10-3 (nominal OD .585") Aluminum Armored Cable.For 0.475” through 0.600” Steel Interlocking Metal Clad Cable .For 0.468” through 0.610” Aluminum Interlocking Metal Clad Cable.For 12/2 through 10/3 Oval NMSE Cable.

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

Boxed8460 08460-6 3/8" 0.90 1.61 0.93 50/500 35.4

TradeSize For Cable Sizes3/8" For 8-4 (nominal OD .785") through 8-2 (nominal OD .680") Steel Armored Cable;

For 8-4 (nominal OD .780") through 8-2 (nominal OD .680") Aluminum Armored Cable.For 0.680” through 0.780” Steel Interlocking Metal Clad Cable .For 0.675” through 0.780” Aluminum Interlocking Metal Clad Cable.

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

Boxed8264 08464-4 1/2" 1.40 1.80 0.40 25/250 25.6

TradeSize For Cable Sizes3/8" For Regular Wall Steel or Aluminum Flexible Metal Conduit.

For 14-2 (nominal OD .460") through 10-3 (nominal OD .500") Steel Armored Cable;For 14-2 (nominal OD .480") through 10-3 (nominal OD .580") Aluminum Armored Cable.For 14-2 (nominal OD .468") through 10-3 (nominal OD .610")Aluminum Interlocking Metal Clad Cable; 14-2 (nominal OD .470")through 10-3 (nominal OD .600") Steel Interlocking Metal Clad Cable.

Catalog UPC No Trade Ctn/Case CaseNumber 0-87115 Size Qty/Qty Wt.

Boxed8243 08243-56 3/8" 25/250 26.6

Certification:

E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18NEMA FB-1 NEC Articles 333

Certification:

E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18NEMA FB-1 NEC Articles 333

Certification:

E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18NEMA FB-1 NEC Articles 333

Zamak Kutu Ba¤lant› Aparat› :Z›rhl› kablolar›n kutu ve panolara 1/2” delikçap›nda ba¤lant›s›nda kullan›l›r.

Saddle Connectorð

Strap Connector

Use:Strap Connectors are used to terminate Armored Cableand Metal Clad to a steel outlet box or metal enclosure.

Duplex Connectorð

Use:Duplex connectors are used to terminate two runsof Armored Cable, Metal Clad Cable or FlexibleMetal Conduit to a 1/2" knock-out in a dry locationbox or enclosure.• Clamp Type• Double Screw

ELECTRICAL PRODUCTS

Materials:• Zinc Die-Cast

Use:Saddle connectors are used to terminate Armoredand Metal Clad Cables to a 1/2" knock-out in a drylocation box or enclosure.• UL Listed Locknut• End Stopped

Materials:• Zinc Die-Cast

Materials:• Zinc Die-Cast

Zamak Kutu Ba¤lant› Aparat› :Z›rhl› kablolar›n kutu ve panolara 1/2” delikçap›nda ba¤lant›s›nda kullan›l›r.

Zamak ‹kili Kutu Ba¤lant› Aparat› :Z›rhl› kablolar, spiral metal borular›n,ikili olarakkutu ve panolara 1/2” delik çap›nda ba¤lant›s›ndakullan›l›r.

CONDUIT FITTINGSFlexible Steel Conduit Fittings/Galvaniz Çelik Spiral Boru Aksesuarlar›

Page 36: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

B 36

www.afielektrik.com

TradeSize For Cable Sizes3/8" For Regular Wall Steel or Aluminum Flexible Metal Conduit.

For 14-2 (nominal OD .460") through 10-3 (nominal OD .500") Steel Armored Cable;For 14-2 (nominal OD .480") through 10-3 (nominal OD .580") Aluminum Armored Cable.For 14-2 (nominal OD .468") through 10-3 (nominal OD .610")Aluminum Interlocking Metal Clad Cable; 14-2 (nominal OD .470")through 10-3 (nominal OD .600") Steel Interlocking Metal Clad Cable.

Boxed8217 08217-6 1/2”-3/8" 0.72 0.93 1.34 50/500 34.3

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

Boxed8218 08218-3 1/2”-1/2" 0.72 0.93 1.34 50/500 34.38219 08219-3 3/4”-3/4" 0.72 0.94 1.62 25/250 21.9

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

Boxed8242 08242-8 3/8" 1.60 1.50 0.42 25/250 26.6

Certification:

E210498 LR57925

Certification:

E210498 LR57925

CONDUIT FITTINGSFlexible Steel Conduit Fittings/Galvaniz Çelik Spiral Boru Aksesuarlar›

Zamak ‹kili Kutu Ba¤lant› Aparat› :Z›rhl› kablolar, spiral metal borular›n,ikili olarakkutu ve panolara 1/2” delik çap›nda ba¤lant›s›ndakullan›l›r.

Strap Connector

Use:Duplex connectors are used to terminate two runsof Armored Cable, Metal Clad Cable or FlexibleMetal Conduit to a 1/2" knock-out in a dry locationbox or enclosure.

• Clamp Type

• Single Screw

EMT To Flex Coupling

Use:Combination couplings are used to provide a transitionfrom steel EMT conduit to Flexible Metal Conduit.• Set Screw - Clamp Type

ELECTRICAL PRODUCTS

Materials:• Zinc Die-Cast

Vidal› Zamak EMT-Flex Ba¤lant› Mufu:EMT boru ve çelik spiral borununbirlefltirilmesinde kullan›l›r.

Materials:• Zinc Die-Cast

Use:Combination couplings are used to provide a transitionfrom steel EMT conduit to Flexible Metal Conduit.• Set Screw - Clamp Type

Materials:• Zinc Die-Cast

Vidal› Zamak EMT-Flex Ba¤lant› Mufu:EMT boru ve çelik spiral borununbirlefltirilmesinde kullan›l›r.

Certification:

E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18NEMA FB-1 NEC Articles 333

EMT To Flex Coupling

Page 37: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

www.afielektrik.comB 37

Boxed9265 09265-6 0 35/500 159266 09266-3 1 35/400 129267 09267-0 2 35/300 189268 09268-7 3 20/200 169269 09269-4 4 16/100 9

Catalog UPC No Trade Ctn/Case CaseNumber 0-87115 Size Qty/Qty Wt.

Use:Snap-in connectors are used to terminate Armoredcable.• No tools needed• Single unit construction eliminates loose

component parts, integral green plastic insulatedthroat bushing provides maximum protection forwire installation.

• No locknut required

Materials:• Steel

Snap-in Flex

Çelik Kablo Sonlama :Z›rhl› kablolar›n sonland›r›lmas›nda kullan›l›r.

Boxed9590 09590-9 1/2" 1.44 0.88 - 50/500 37.59591 09591-6 3/4" 1.69 1.31 - 25/250 36

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

Boxed9593 09593-0 1/2” 1.63 1.69 - 20/200 20.4

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

Certification:

E238299

Materials:• Galvanized Steel• Zinc PlatedUse:

One hole starps are used to provide support for runsof Armored Cable.

BX One Hole Strap

Galvaniz Çelik Tek Delikli Krofle:Z›rhl› kablolar› sabitlemede kullan›l›r.

Boxed9300 09300-4 3/8" 1.27 0.5 0.47 100/1000 13.99301 09301-1 1/2" 1.43 0.5 0.47 50/1000 1.1

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

Certification:

E155411 LR57925

Boxed8210 08210-7 1/2” 1.40 0.92 0.15 50/500 40.98211 08211-4 3/4” 1.52 1.12 0.20 25/250 30.8

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C Qty/Qty Wt.

Anti-Short Bushing

Plastik Kablo ve Spiral Boru Sonlama :Z›rhl› kablolar›n ve spiral çelik borular›nsonland›r›lmas›nda kullan›l›r.

Use:Anti-short bushings are inserted into the end ofArmored Cable and Flexible Metal Conduit in orderto protect the conductors from the sharp edges ofthe raceway where cut.Materials:• Plastic

Use:Combination couplings are used to provide a transitionfrom steel EMT conduit to Flexible Metal Conduit.• Compression - Screw in Type

Materials:• Zinc Die-Cast

S›kmal› Zamak EMT-Flex Ba¤lant› Mufu:EMT boru ve çelik spiral borununbirlefltirilmesinde kullan›l›r.

ELECTRICAL PRODUCTS

CONDUIT FITTINGSFlexible Steel Conduit Fittings/Galvaniz Çelik Spiral Boru Aksesuarlar›

Page 38: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

ELECTRICAL PRODUCTS

NM / SE CABLE

NM / SE CABLECatalog UPC No Trade Grommet Opening Wire Ctn/Case CaseNumber 0-87115 Size Minimum Maximum Size Qty/Qty Wt.

NM / SE CABLECatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9258 09258-8 3/16” OD 0.69 0.32 0.19 - 100/1000 3.49259 09259-5 1/4” OD 0.99 0.52 0.23 - 100/1000 6.5

NM / SE CABLECatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9250 09250-2 3#8,6,4 1.39 0.50 0.35 - 100/1000 14.39251 09251-9 3#3,2 1.69 0.56 0.44 - 100/1000 20.69252 09252-6 3#1,1/0,2/0 1.94 0.56 0.56 - 25/250 23.69253 09253-3 3#3/0,4/0 2.50 1.00 0.84 - 25/250 22.5

NM / SE Cable Connector

Certification: E155410 E213494 LR57925

Catalog UPC No Trade Wire Ctn/Case CaseNumber 0-87115 Size Size Qty/Qty Wt.

Boxed8404 08404-0 1” 3#4 10/100 268406 08406-4 1” 3#6 10/100 258408 08408-8 1” 3#8 10/100 258411 08411-8 1 1/4” 3#1 10/50 268412 08412-5 1 1/4” 3#2 10/50 218413 08413-2 1 1/4” 3#3 10/50 528410 08410-1 1 1/2” 3#1/0 5/25 168420 08420-0 1 1/2” 3#2/0 5/25 238430 08430-9 2” 3#1/0 5/25 238431 08431-6 2” 3#2/0 5/50 458432 08432-3 2” 3#3/0 5/50 458440 08440-8 2” 3#4/0 5/25 23.58440-L 08417-0 2” 3#4/0 5/25 23.5

Materials:• Stamped Steel• Zinc Plated

Standards:UL 514B, CSA C22.2 No. 18NEMA FB-1, NEC Articles 338

UF Connectors

Boxed8376 08376-0 1/2" .10 x .22 .44 x .47 12/2 25/250 24.38377 08377-7 3/4" .17 x .22 .66 x .80 12/3 25/250 38.3

Use:Watertight connectors are used for sealing andterminating Oval Type SE or USE Cable to athreaded entry of a watertight box or enclosure.

Materials:• Zinc Die-Cast

Use:Used to connect underground feeder cableto a weather proof box with threaded hub.• For Underground Feeder Cable Only

Materials:• Zinc Die-Cast

Certification: E155411 LR57925

One Hole SEU Straps

Use:One hole straps are used to secureType SE or USE Service Entrance Cable.

Zamak S›v› S›zd›rmaz DiflliKablo Ba¤lant› Rakoru :UL/NEC tip oval SE ve USE kablolar›n panove kutu girifllerinde sabitlenmesi ve kablolar›nsonland›r›lmas› amac›yla kullan›l›r.

Zamak S›v› S›zd›rmaz DiflliKablo Ba¤lant› Rakoru :UL/NEC tip feeder yeralt› kablolar›n›n pano vekutu girifllerinde sonland›r›lmas› vesabitlenmesi amac›yla kullan›l›r.

Mini One Hole Straps

Use:Midget one hole straps are used to secure baresolid copper wire to a working surface. Materials:

• Stamped Steel• Zinc Plated

Tek Delikli Kablo Sabitleme Kroflesi :Ç›plak bak›r iletkenlerin sabitlenmesindekullan›l›r.

Tek Delikli Kablo Sabitleme Kroflesi :UL/NEC tip SE ve USE kablolar›n sabitlenmesiamac›yla kullan›l›r.

B 38

www.afielektrik.com

CONDUIT FITTINGSService Entrance Cable Connectors/Kablo Rakorlar› ve Aksesuarlar›

Page 39: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

www.afielektrik.comB 39

ELECTRICAL PRODUCTS

NM / SE CABLECatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9254 09254-0 #8,6,4 2.38 0.75 0.38 - 100/1000 30.09255 09255-0 #3,2 2.75 0.75 0.50 - 100/1000 34.99256 09256-4 #1,0,1/0,2/0 3.19 0.75 0.75 - 25/250 12.89257 09257-1 #3/0-4/0 3.50 0.75 0.81 - 25/250 13.9

NM / SE CABLECatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed180 70905-9 1/2” 2.25 2.22 1.93 - 50 24181 70910-3 3/4” 2.48 2.51 2.20 - 50 24182 70915-8 1” 2.75 2.85 2.55 - 25 10183 70920-2 1 1/4” 3.12 2.90 2.98 - 25 14184 70925-7 1 1/2” 3.75 3.68 3.18 - 15 13185 70930-1 2” 4.34 5.28 4.61 - 5 81866 70935-6 2 1/2” 5.64 5.52 5.20 - 1 4.52877 70932-5 3” 6.39 6.25 5.26 - 1 72888 70945-5 3 1/2” 6.82 6.85 7.16 - 1 6.52899 70950-9 4” 7.65 6.85 7.25 - 1 6.5

NM / SE CABLECatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8160 08160-5 1/2” 0.97 2.19 2.04 - 5/50 158161 08161-2 3/4” 1.16 2.41 2.13 - 5/25 8.88162 08162-9 1” 1.51 2.83 2.54 - 10 4.88163 08163-6 1 1/4” 1.89 2.89 3.00 - 10 5.28464 08164-3 1 1/2” 2.16 3.51 3.20 - 10 5.28165 08165-0 2” 2.70 4.36 4.58 - 5 7.7

Certification: E121487 LR57925

Certification: E121487 LR57925

Two Hole SEU Straps

Use:Two hole straps are used to secureType SE or USE Service Entrance Cable.

Clamp OnService Entrance Heads

Use:Service entrance caps are used as a connectingpoint in an overhead service entrance and can bemounted on threaded or unthreaded RigidConduit, IMC or EMT Conduit.• Clamp-On Type• Phenolic Insulator with Multiple Holes• Listed for Use in Wet Locations

Materials:• Aluminum Die-Cast

Materials:• Stamped Steel• Zinc Plated

Çift Delikli Kablo Sabitleme Kroflesi :UL/NEC tip SE ve USE kablolar›nsabitlenmesinde kullan›l›r.

Standards:UL 514B CSA C22.2 No. 18NEC Articles 345, 346 & 348

Alüminyum Döküm Vidal› Kablo Ba¤lant› Aparat› :Havai hat kablolar›n›n biraraya getirilip bir noktadatoplanmas›n› sa¤lamak amac›yla kullan›l›r. Diflli borular›nucuna da eklemeye uygundur.

Threaded ServiceEntrance Heads

Use:Service entrance caps are used as a connectingpoint in an overhead service entrance and can bemounted on threaded Rigid Conduit and IMC.• Threaded Type• Phenolic Insulator with Multiple Holes• Listed for Use in Wet Locations

Standards:UL 514B CSA C22.2 No. 18NEC Articles 345, 346 & 348

Materials:• Aluminum Die-Cast

Alüminyum Döküm Diflli Kablo Ba¤lant› Aparat› :Havai hat kablolar›n›n biraraya getirilip tek bir noktadatoplanmas›n› sa¤lamak amac›yla kullan›l›r. Diflli borular›nucuna eklemeye de uygundur.

CONDUIT FITTINGSService Entrance Cable Connectors/Kablo Rakorlar› ve Aksesuarlar›

Page 40: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

B 40

www.afielektrik.com

CONDUIT FITTINGSService Entrance Cable Connectors/Kablo Rakorlar› ve Aksesuarlar›

ELECTRICAL PRODUCTS

NM / SE CABLE

NM / SE CABLE

Catalog UPC No Pipe Head Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size Size A B C Unit Qty/Qty Wt.

Boxed9366 09366-0 2” 1 1/4” 2.66 3.72 3.14 - 4 39367 09367-7 2 1/2” 1 1/4” 3.28 4.05 3.08 - 2 29368 09368-4 2 1/2” 2” 3.12 4.57 4.20 - 2 2

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9364 09364-6 3#8-3#1 3.47 1.90 2.80 - 5 1.49364 09365-3 31/0-3#4/0 4.90 2.90 4.30 - 5 3.3

Certification:

E121487 LR57925

Certification: E155410 LR57925

Kablo Sabitleme Aparat› :Havai hat kablolar›n›n biraraya getirilip tekbir noktada toplanmas›n› sa¤lamak amac›ylakullan›l›r. Diflli borular›n ucuna eklemeye deuygundur.

Service Entrance Mast Heads

Oval Service Cable Heads

Use:Die-cast oval service entrance caps are used as aconnecting point in an overhead service entrancefor SEU Cable.

• Removable Cap• 2-Piece Phenolic Insulator• Listed for Use in Wet Locations

Materials:• Aluminum Die-Cast

Use:Service entrance caps are used as a connectingpoint in an overhead service entrance and can bemounted on threaded or unthreaded RigidConduit, IMC or EMT Conduit.• Slip Fit• Phenolic Insulator with Multiple Holes• Listed for Use in Wet Locations

Materials:• Aluminum Die-Cast

Standards:UL 514B CSA C22.2 No. 18NEC Articles 345, 346 & 348

Standards:UL 514B CSA C22.2 No. 18NEC Articles 345, 346 & 348

Oval Kablo Sabitleme Kroflesi :UL/NEC tip SEU Havai hat kablolar›n›n birnoktada düzenlenmesini sa¤lar. Hareketlikapa¤› sayesinde kullan›m kolayl›¤› sa¤lar.

Page 41: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

CatalogNumber

CatalogNumber

CONDUIT FITTINGSService Entrance Cable Connectors/Kablo Rakorlar› ve Aksesuarlar›

PVC Service Entrance Heads

PVC Oval Service Cable Heads

Use:Service entrance caps are used as a connectingpoint in an overhead service entrance and can bemounted on threaded or unthreaded Rigid, IMC,PVC or EMT Conduit.• For Rigid, IMC, PVC & EMT (edeptor sleeve included)• Supplied with screw and nut• Rigid, weather-resistant design• Acts as an insulator of high dielectric strength• Meets UL & CSA specifications

Materials:• Plastic

E161187

Oval Kablo Sabitleme Kroflesi :Havai hat kablolar›n›n bir noktadadüzenlenmesi amac›yla kullan›l›r. Hareketlikapa¤› sayesinde kullan›m kolayl›¤› sa¤lar.IMC, Rigid, PVC ve EMT borularlakullanmaya uygundur.

Oval Kablo Sabitleme Kroflesi :Havai hat kablolar›n›n bir noktadadüzenlenmesikablolar›n›n birbirine eklenmesiamac›yla kullan›l›r. Hareketli kapa¤›sayesinde kullan›m kolayl›¤› sa¤lar.

www.afielektrik.comB 41

ELECTRICAL PRODUCTS

NM / SE CABLE

*Dimension “G” conforms to UL specs for metallic conduit. Adapter sleeve included for EMT.

NM / SE CABLE

Nominal Dimension BoxSize A B C D E F G* H J Qty.

Boxed7200 1/2” 2 2.718 1.5 1.968 0.687 0.937 0.855 2.609 0.312 257201 3/4” 2.406 2.296 1.718 2.234 0.812 0.937 1.065 1.25 0.437 257202 1” 2.406 2.296 1.968 2.234 0.812 1.125 1.33 1.312 0.437 207203 1 1/4” 3.031 4.031 2.343 2.656 0.875 1.093 1.675 1.89 0.531 107204 1 1/2” 2.406 2.296 1.968 2.234 0.812 1.125 1.33 1.312 0.437 107205 2” 3.031 4.031 2.343 2.656 0.875 1.093 1.675 1.89 0.531 5

UPC No Nominal Dimension Box0-87115 Size A B C D E F G Qty.

Boxed7206 07206-1 #8, 6, 4, 2 2 2.718 1.343 1.125 0.687 0.531 1.968 307207 07207-8 #0,00 3.031 4.031 1.75 1.375 1.125 0.687 2.875 107208 07208-5 #000, 0000 3.031 4.031 2.125 1.625 1.125 0.687 2.875 10

Use:PVC oval service entrance caps are used as aconnecting point in an overhead service entrancefor SEU Cable.

• Accommodates 3-conductor No.8 AWG to 3-conductor No. 0000 AWG cables.• Supplied with screw and nut• Rigid, weather-resistant meterial• Galvanized back plate for easy installation• Meets UL specifications

Materials:• Plastic

E36810

Page 42: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

NM / SE CABLE

NM / SE CABLEUPC No Nominal Dimension Box0-87115 A B C D E F G* H I Qty.

Boxed7210 07210-8 2.187 0.968 0.750 3.093 1.406 1.093 2.968 0.078 25° 10/100

Type SLB - Aluminum Conduit Entrance Ells

Cover, gasket & screw included, for rigid conduit

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9245 09245-8 1/2” 1.312 0.95 0.65 - 100/1000 55.09246 09246-5 3/4”-1” 1.75 1.25 0.76 - 50/500 39.59247 09247-2 1 1/4” 2.125 1.63 0.76 - 100/1000 55.09248 09248-9 1 1/4” 2.50 1.97 0.79 - 50/500 39.5

Unit UPC Conduit Description Case Case0-87115 Size Type Color Qty. Weight

Boxed500 75005-1 1/2” SLB Threaded Grey 38 8501 75010-5 3/4” SLB Threaded Grey 36 8502 75015-0 1” SLB Threaded Grey 12 6503 75020-4 1-1/4” SLB Threaded Grey 12 11.5504 75025-9 1-1/2” SLB Threaded Grey 10 10505 75030-3 2” SLB Threaded Grey 4 5.5503-XL 71035-2 1-1/4” XLSLB Threaded Grey 5 6505-XL 71040-6 2” XLSLB Threaded Grey 5 14

Certification: E21488 LR57925

www.afielektrik.com

ELECTRICAL PRODUCTS

CatalogNumber

CatalogNumberBWF#

CONDUIT FITTINGSService Entrance Cable Connectors/Kablo Rakorlar› ve Aksesuarlar›

B 42

Use:Service entrance ells are usedto gain access to the interior ofa raceway for wire pulling, inspectionand maintenance.• Listed for Use in Wet LocationMaterials:• Aluminum Die-CastAlüminyum Döküm Kondulet :Kablo çekmede ve kablolardan ek almaktakullan›l›r. Vidal› kapa¤› sayesindekablo ek yerlerine müdahaleyi ve bak›m›kolaylaflt›r›r.

‹ki Parçal› Çelik Sabitleme Kroflesi :PVC kapl› kablolar›n pano ya da kutugirifllerinde sabitlenmesi için kullan›l›r.

2-Piece Connectors

Service Cable Sill Plates

Service Entrance Ells

Standards:UL 514B CSA C22.2 No. 18NEMA FB-1 NEC Articles 338

Use:Sill plates are used in conjunction with sealingcompound to protect service entrance cable andto cover the hole where t enters the dwelling.• Covers service cable where it bends to enter the building for an attractive finish• May be used on all cable sizes from three #4 to three #0• Unaffected by seasonal temperature extremes

Materials:• PVC

Girifl Plakas› :fiebeke kablolar›n›n geçti¤i deliklerdeüzerini kapatmak ve d›fl etkenlerdenkorumak için kullan›l›r.

Use:Piece clamp type connectors are usedtoterminate one or more Nonmetallic SheathedCables to a knock-out in a dry location box orenclosure. Also used in old work locations.• No Locknut Required• Butterfly Style

Materials:• Steel

Page 43: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

ELECTRICAL PRODUCTS

NM / SE CABLE

NM / SE CABLE

Use:Porcelain wireholders are used in overheadservices to support and secure incoming serviceentrance wires prior to entrance.• Reinforced

Materials:• Porcelain• Steel

Use:Porcelain wireholders are used in overheadservices to support and secure incoming serviceentrance wires prior to entrance.• Clamp-On• Mounts Below Service Entrance Cap

Materials:• Porcelain• Steel

Use:Porcelain wireholders are used in overheadservices to support and secure incoming serviceentrance wires prior to entrance.

Materials:• Porcelain• Steel

Use:Conduit supports are used to secure ServiceEntrance Conduit to the outside surface of abuilding•1/2” x 10” Stud BoltMaterials:• Steel

NM / SE CABLE

NM / SE CABLE

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-31857 Size A B C Unit Qty/Qty Wt.

Boxed7500 07500 0 2 1/4” Lag 5.26 1.54 2.50 - 50 35.5

Catalog UPC No Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-31857 A B C Unit Qty/Qty Wt.

Boxed7503 07503-1 2.80 1.70 3.37 - 20 30.4

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-31857 Size A B C Unit Qty/Qty Wt.

Boxed7505 07505-0 1-11/16” 3.88 1.44 2.13 - 10/1000 28.07506 07506-2 2-1/4” 4.80 1.95 2.64 - 50 30.5

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-31857 Size A B C Unit Qty/Qty Wt.

Boxed7509 07509-3 1 1/4”-3”” 5.36 4.10 0.15 - 20 7.7

Heavy Duty Porcelain Wireholders

Adjustable Wireholders

Standard Porcelain Wireholders

Universal Conduit Supports

www.afielektrik.comB 43

CONDUIT FITTINGSService Entrance Cable Connectors/Kablo Rakorlar› ve Aksesuarlar›

Porselen Kablo Tutucu :Havai hat kablolar›n›n sabitlenmesinde, tesisatkablolar›n›n girifllerinden önce güvenli birflekilde sabitlenmesinde kullan›l›r.

Ayanlanabilen Porselen Kablo Tutucu :Kablolar›n girifllerden önce rigid hale gelmesive hasar görmeden çekilmesini sa¤lar,kablo kesitlerine göre ayarlanabilir.

Standart Porselen Kablo Tutucu :Havai hat kablolar›n›n sabitlenmesinde,tesisat kablolar›n›n girifllerinden önce güvenlibir flekilde sabitlenmesinde kullan›l›r.

Universal Çelik Boru Deste¤i :Kablolar›n boru ile tafl›nmas› esnas›ndaborunun yüzeye sabitlenmesinde kullan›l›r.

Page 44: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

ELECTRICAL PRODUCTS

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8470 08470-5 3/8" 0.80 1.17 0.39 - 100/1000 47.88471 08471-2 3/4" 0.94 1.67 0.42 - 50/500 44.18472 08472-9 1" 1.12 1.95 0.44 - 25/250 34.98473 08473-6 1 1/4" 2.25 1.31 0.60 - 10/100 28.1

NM / SE CABLE

Use:Roof flashings are used to provide a watertightseal in overhead services where the conduit mastpenetrates the roofs surface.

Materials:• Neoprene

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8474 08474-3 1 1/2" 2.87 1.33 0.60 - 5/50 19.08475 08475-0 2" 3.50 1.57 0.74 - 10/40 21.5

TradeSize For Cable Sizes3/8" For one or two 14-2 to 12-2 Nonmetallic Sheathed Cables or one 0.29" to 0.45"

diameter Flexible Cord.3/4" For 10-3 to 8-2 Nonmetallic Sheathed and 8-3 to 4-3 Oval Service Entrance

Cable and 8-3 to 6-3 Round Service Entrance Cable.1" For 10-3 to 4-3 Nonmetallic Sheathed and 6-3 to 4-3 Oval Service Entrance

Cable and 6-3 to 2-3 Round Service Entrance Cable1 1/4" 4-3 to 2-3 Nonmetallic Sheathed and 1.19” Service Entrance Cable.1 1/2" For 1.48” Service Entrance Cable.

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Articles 336 & 338

Use:Clamp type connectors are used to terminateNonmetallic Sheathed and Oval Type SE or USECables to a knock-out in a dry location box orenclosure.• UL Listed Locknut• Male Hub Threads NPS

Materials:• Zinc Die-Cast

Certification: E213494 / E155410 LR57925

Zamak Kablo Sabitleme Kroflesi :UL/NEC tip NM ve Oval tip SE ya da USE kablolar›n›n pano ve kutu girifllerindesabitlenmesinde kullan›l›r.

Catalog UPC No Trade Base Ctn/Case CaseNumber 0-87115 Size Size Qty/Qty Wt.

*Indicates Combo unit that can be used for all 3 sizes.

NM / SE CABLE

Boxed7119* 07119-4 1 1/2",2",3" 8 7/8"x11 3/4" 10 10.07120 07120-0 4" 8 7/8"x11 3/4" 10 10.0

B 44

www.afielektrik.com

Clamp Type Connectors(NM Sheathed)

Roof Flashings

Clamp Type Connectors(Oval Type SE)

Boru Cephe Girifli :Havai hat kablolar›n›n boru içerisinde çat›yüzeyinden güvenle girifl yapmas›n›sa¤lar. Contas› sayesinde s›v›s›zd›rmazd›r.

CONDUIT FITTINGSService Entrance Cable Connectors/Kablo Rakorlar› ve Aksesuarlar›

Page 45: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

ELECTRICAL PRODUCTS

Catalog UPC No Trade Ctn/Case CaseNumber 0-87115 Size Qty/Qty Wt.

Boxed7117 07117-0 3/8”-1/2” 100/1000 7.0

Plastic Nonmetallic CableConnectors

Plastic Nonmetallic CableConnectors

TradeSize One Cable Two Cables

3/8" (1) 14/2 -10/2 (2) 14/2- 10/2(1) 14/3- 10-3 (1) 14/2 & 12/2

(1) 14/2 & 10/2(1) 12/2 & 10/2

• Accommodates one or two 4-2, 14-3 and12-2 cables, one 12-3, 10-2 and 10-3 cable,and one or two .300 inch or .600 inchdiameter cords

• Push-in design with a captive lockwedge that secures cable with a singlesqueeze from standard electrician’s pliers

• Excellent insulation, superior strain relief• Sized to fit 1/2 inch (12.70mm) knockout size

Catalog UPC No Trade Nominal Dimensions Ctn/Case CaseNumber 0-87115 Size A B C D E Qty/Qty Wt.

Boxed7118 07118-7 1/2” 1.34 2.42 .834 .883 .825 50/250 8.1

NM / SE CABLE

NM / SE CABLE

Use:Plastic nonmetallic cable connectors are used toterminate Nonmetallic Sheathed Cable or FlexibleCord to knockout in a dry location box or enclosure.• Snap-In One Piece Construction• Wide Variety of Cable Configurations

Materials:• Plastic

Use:Plastic nonmetallic cable connectors are used toterminate Nonmetallic Sheathed Cable toknockout in a dry location box or enclosure.• Snap-In One Piece Construction• Wide Variety of Cable Configurations

Materials:• Plastic

www.afielektrik.comB 45

Plastik Kablo Girifl Aparat› :Hassas kablolar›n pano ve kutulardasonland›r›lmas›nda kullan›l›r.

Plastik Kablo Girifl Aparat› :Hassas ve flexible kablolar›n pano vekutularda sonland›r›lmas›nda kullan›l›r.

CONDUIT FITTINGSService Entrance Cable Connectors/Kablo Rakorlar› ve Aksesuarlar›

Page 46: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

ELECTRICAL PRODUCTS

Use:Designed to secura rigid, IMC or EMTacross, parallel or perpendicular to beam,channel and angle supports.Boru Ask› Aparat›:Elektrik borular›n›n sabitlenmesinde vedesteklenmesinde kullan›lan çelik ba¤lant›elemanlar›d›r. Her türlü metal ve plastikborunun tava, kirifl, kablo tavas› ve benzeriyap›lara montaj›nda kullan›l›r.Features:* Easily installed* Capable of withstanding heavy loadsMaterialAll components are Malleable iron exceptnuts and bolts which are steel,Finish:Clamp - Hot dipped GalvanizedHardware - Mechanically Galvanized

Conduit U-Bolts

Features:* 2 hex nuts

MaterialSteel

Finish:Mechanically Galvanized

Çelik U-Civata :Borular›n muhtelif yüzeyleresabitlenmesinde kullan›l›r.

Type UBC Right Angle Type UPC Parallel Type UEC EdgeType

CatalogNumberParallel

CatalogNumber

UPC-50GUPC-75GUPC-100GUPC-125GUPC-150GUPC-200GUPC-250GUPC-300GUPC-350GUPC-400G

UEC-50GUEC-75GUEC-100GUEC-125GUEC-150GUEC-200GUEC-250GUEC-300G

Note:Edge type UEC used for rigid conduit only.

W /O Nut & Bolt

Materials:• Stamped Steel

Conduit HangerW / Nut & Bolt

Finish:• Zinc Plated

Certification:

E186443 LR104691

Use:Conduit hangers are usedto secure and suspendEMT, Rigid, IMC and PVCConduits fromoverhead supports.• With Carriage Bolt andNut Attached

Type UDimensions (›nches)A B C D

ThreadSize

111222344567

222334455678

111111111111

- 20- 20- 18- 18- 18- 16- 16- 16- 16- 16- 16- 16

3/41/4

5/165/165/163/83/83/83/83/83/83/8

1/21/21/21/21/23/43/43/43/43/43/4

1/21/2

13/161/41/2

1/21/4

11/161/43/83/8

15/161/87/163/4

1/2

5/81/85/85/8

11/16

3/167/163/41/165/167/83/8

1/2

1/16

11122334456 B

A

C

D

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9450 09450-6 1/2" 1.95 0.75 0.70 - 50/500 38.69451 09451-3 3/4" 2.21 0.75 0.82 - 100 8.39452 09452-0 1" 2.53 0.86 0.93 - 100 10.09452-E 09428-5 1 1/4" 2.72 0.86 0.98 - 100 12.29453 09453-7 1 1/2" 3.01 0.86 1.03 - 100 13.59455 09455-1 2" 3.31 0.96 1.10 - 100 18.99456 09456-8 2 1/2" 4.05 0.96 1.12 - 50 10.79457 09457-5 3" 4.60 1.18 1.25 - 25 7.59458 09458-2 3 1/2" 5.31 1.18 1.25 - 10 4.69459 09459-9 4" 5.31 1.18 1.25 - 10 4.6

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9440 09440-7 1/2" 1.95 0.75 0.70 - 50/500 38.69441 09441-4 3/4" 2.21 0.75 0.82 - 100 8.39442 09442-1 1" 2.53 0.86 0.93 - 100 10.09442-E 09427-8 1 1/4" 2.72 0.86 0.98 - 100 12.29443 09443-8 1 1/2" 3.01 0.86 1.03 - 100 13.59445 09445-2 2" 3.31 0.96 1.10 - 100 18.99446 09446-9 2 1/2" 4.05 0.96 1.12 - 50 10.79447 09447-6 3" 4.60 1.18 1.25 - 25 7.59448 09448-3 3 1/2" 5.31 1.18 1.25 - 10 4.69449 09449-0 4" 5.31 1.18 1.25 - 10 4.6

PARALELT‹P UPC-G

90ºT‹P UBC-G

KÖfiEL‹T‹P UEC-G

B 46

www.afielektrik.com

CONDUIT HANGERSBoru Ask› Aparatlar›

Vidal› Boru Kroflesi :Metal ve PVC borular›ntijle as›lmas›nda kullan›l›r.Civata ve somun dahil veyahariç siparifl edilebilir.

1/41/2

1/2

1/2

1/23/4

TradeSize

1112233456

UBC-50GUBC-75GUBC-100GUBC-125GUBC-150GUBC-200GUBC-250GUBC-300GUBC-350GUBC-400GUBC-500GUBC-600G

CatalogNumber

90˚

1/23/4

TradeSize

1112233456

1/41/2

1/2

1/2

CatalogNumber

U-50SGU-75SGU-100SGU-125SGU-150SGU-200SGU-250SGU-300SGU-350SGU-400SGU-500SGU-600SG

Page 47: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

1/2

1/2

1/2

1/2

CABLE TRAY CLAMPS

Type IS

Use:Provides support for conduithanging systems.Mengene:Borular›n ask›l› olaraktafl›nmas›nda kullan›lan parçad›r.Material:Malleable Iron clampSteel Screw, case hardenedFinish:Clamp - Hot Dip GalvanizedScrew - Zinc Electroplated

BEAM CLAMPS

Type CTC

Use:For connecting and groundingrigid conduit, IMC, EMT to trays.Kablo Tavas› Ba¤lant› Eleman›:Diflli ve diflsiz borular›n kablotavas›na ba¤lant›s› ve topraklaman›ndevam›n›n sa¤lanmas›nda kullan›l›r.Features:* Fast installation, low product cost* Strength, design, continuityMaterial/Finish:Malleable Iron/MechanicallyGalvanized U - Bolts and Nut:Steel / Mechanically Galvanized

1/4

5/163/161/2

1/2

5/8

7/8

1/83/8

11/16

5/8

5/813/161/161/4

CatalogNumber

CatalogNumber Dimensions

Use:Provides support for conduithanging systems.

Strut

C ProfilTij veya farkl› desteklerle borular›n dikeyde veyatayda kroflelerle sabitlenerek, tafl›nmas›ndakullan›l›r.

Load.LBS.

100 pieceWeight

(kg)

Thickness

.060

.075

.075

.075

.105

.105

.105

.105

.125

.125

400600600600800800800800

10001000

5779

131518212830

Use:Provides conduits to fixingstruts.

Boru KroflesiBorular› C profile sabitlemedekullan›l›r.

Pipe&Conduit Clamp

TORK-KGWU-BOLTNut

L T U

2752528686868686

www.afielektrik.comB 47

E

D

CTC-150 & CTC-1012”- 1

Kablo Tavas›na Dik.

LT

U

12/ 1

4/

PS-110 10PG-HS 41 x 22 x 3050 mmPS-210 10PG-HS 41 x 41 x 3050 mm

1 58/

58/

36/

14 Gauge

78/

1

A

1/47/87/81/2

5/81/85/8

1/41/41/2

1/21/81/2

1/41/43/83/83/83/83/83/8

1/21/41/2

1/21/43/41/4

1/45/163/163/83/83/83/83/8

23344556

22344556

22345556

- 20- 18- 18- 16- 16- 16- 16- 16

15/1615/1615/16

1/8

7/

A B C D E

MAX.LoadIbs

HoleSize

335335525750900

IS-500IS-509IS-501IS-502IS-503

- 2010 - 24

- 18- 16-13

11

111

11122

11122

3/4

TradeSize

1/4

-1 - 1122334

UL Listed:E-24264

CSA Certified 9795 for rigid and EMT only

Third Party Certification:

ELECTRICAL PRODUCTS

CONDUIT HANGERSBoru Ask› Aparatlar›

- Tapped Holes (2) Load

B - Jaw Opening

A

C

CatalogNumber

STR-050STR-075STR-100STR-125STR-150STR-200STR-250STR-300STR-350STR-400

1/4

1/2

1/2

1/2

1/2

3/4

TradeSize

11122334

CatalogNumber

CTC-0507CTC-1012CTC-150CTC-200CTC-250CTC-300CTC-350CTC-350

Page 48: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

B113 1/ 4" T all

12 Ga.

B122 7/ 16" T all

12 Ga.

B221 5/ 8" T all

12 Ga.14 Ga.16 Ga.

B321 3/ 8" T all

12 Ga.

B5213

/ 16" T all12 Ga.14 Ga.16 Ga.

A Channel X Channel

H1 7/ 8 Channel9/ 16" holes

1 7/ 8" on centers

KO6 Channel7/ 8" dia. knockout

6" on centers

S Channel13/ 32" x 3"slots4" on centers

SH Channel9/ 16" x 7/ 8"slots

2" on centers

B22TH Channel9/ 16" holes

1 7/ 8" on centers

NWOSeries

TN Series

STN Series

HHCS Series LW Series HN SeriesB655, B656

EZ Twirl

FW Series

B202D B129

B141

B341B133 B132

B101 B844W

B261Series

B147-B152B154

B162-B165B155-B161

B172

B107-22A B107

B105

B110

B102

B168

B104

� Plain Channel � Dura-Gr een Channel � Pr e-Galvanized Channel � HDGAF Channel� Special Painted Channel � PVC Coated Channel � Aluminum Channel

B119

B272

B124

ATR Series

Basic Channel 1 5/ 8" Wide Sections, Combinations & Hole Patter ns

Channel Nuts & Hardware

Strut Fittings

N Series

General Information (Channel & Fittings)

Applications: B-Line Systems channel isa basic structural member of the channelframing system. Use of the channel alongwith the appropriate fittings and attachmentspermit the rapid and economical constructionof a virtually unlimited variety of rigid metalsupport structures. Channel sections areroll for med from strip steel coils whilefittings are made from either steel coils orsheet. Refer to page 15 of the B-Line StrutSystems catalog for Channel SelectionTable, pages 16-37 for Channel Load Dataand pages 4-13 for Technical Data. Othersizing charts for conduit, pipe and tubingas well as threaded rod load charts areshown on pages 207-211 of the StrutSystems catalog.Materials:B-Line's standard roll formedchannels are made from PreGalvanized steel conforming to ASTMA 6 5 3 S S , G r a d e 3 3 G 9 0 ( . 4 5 o z .zinc/ft.2). Plain finish channels are rollformed from hot-rolled, pickled andoiled steel conforming to ASTM A570,Grade 33. Certain sections are availableable in Stainless Steel Type 304 & 316(consult factory). Aluminum alloy 6063-T6is used to ext rude severa l channe lsect ions and combinat ion sect ions(consult factory).Finishes:B-Line's standard finishes onchannels are Dura-Green Epoxy andPre Galvanized (as shown above) whilestandard finishes for fittings are Dura-Green Epoxy and Zinc Plated. Plainfinish is also available. (HDGAF) Hot-Dipped Galvanized After Fabrication isavailable on both channel and fittings(not recommended on threaded items)and conforms to one of the followingapplicable specifications: ASTMA123 orASTM A153. Electro Galvanized Zinc(ZNPLT), ASTM B633, is available onmost fittings and can be placed onchanne lspe r cus tomer o rde r PVCcoated and special paint colors areavailable on both channel and fittingsper customer order (p leaseconsultfactory). See B-Line's Strut Systems(SS99) and Pipe Hangers & Supports(PH-00) Engineering Catalogs for moreproduct information. Many productscomply with the following:Manufacturers Standardization SocietySpecifications MSS-SP-58 and MSS-SP-69.Federal Specification WW-H-171e.Underwriters Laboratories Surface MetalRaceways.ASTM B633.ASTM A653 SS, Grade 33 G90ASTM A570, Grade 33

B 48

www.afielektrik.com

CONDUIT HANGERSBoru Ask› Aparatlar›

Page 49: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

Strut Fittings

Concrete Inserts - Continuous & Spot

Beam Clamps

B279 B280SQB281FL

B409Series

B297Series

B591Series

B494Series

B613

B376 B203-B206B220-B223

B822

B22I, B32I,B52I

B2500B2503

B2501

B2505-B2508

B351, B351L

B441-22, B441-22AB751-J4-J12 B750 Series

B303-B309, B321Series

B3362thru

B3365

B312

Upper Attachments

Brackets

B3063B3064

B3066

B3019

B3020B3014

B3036L B3031-3/8 B3034

B3367

B3054

B3055 B211B3291 thru

B3298

B3087

B3062

B3060

B3199B3070

B3080 B3085

B3083

www.afielektrik.comB 49

CONDUIT HANGERSBoru Ask› Aparatlar›

Page 50: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

B 50

www.afielektrik.com

Pipe Clamps & Hangers

Rollers, Guides & Saddles

Seismic Fittings

B3170 B3174 B3690 B3690C B3690FB1400

B3198H B3171 B3100 B3100F B3106 & B3106VB3190 B3191B386

B3147A & B B3373 B3140B3144

B3110 B3122AB3114 B3117SL B3126

B218 B379

B2000 Series

BVT SeriesVibra-Clamps

B3195

B2610

Vibra-Cushion

B2207-B2213B2400

B3088TB3092B3088

B3090 B3151B3281 - B3287

B3380 thru B3384

B634 SC228 SC-UB

B3152

B3160 - B3165B3891 - B3897 B3256

B633Series

B335Series

CONDUIT HANGERSBoru Ask› Aparatlar›

Page 51: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

www.afielektrik.comB 51

Pipe Hangers & Supports

Vibraatol™ Accessories

Accessories

B3203

B3200

B3205

B3213B3234

B3210X

B3202

B3188

B3201

Electrical Accessories

B465 B217, B217P

B392Series

B616Series

B516S

B719

B768 SeriesB766

B4033 SeriesMaple Clamps

B4060 thru B4093Por celain Clamps

B390S

ANH

CNP

HESL/HES

HMLE/HME

HSL/HSHML T/HMT

VRP

CONDUIT HANGERSBoru Ask› Aparatlar›

Page 52: EMT Compression Connectors/Die Cast - EMT Boru | IMC Boru · *EMT, IMC & RIGID ELECTRICAL PRODUCTS UL Listed: E210498 CSA Certified:LR57925 Certification: UL Listed: E210498 CSA Certified:LR57925

Metal Framing Mechanical Applications• Piping Racks• Tunnel Pipe Stanchions• Concrete Inserts• Beam Attachments• Pipe RisersMetal Framing Industrial Applications• Racks and Shelving• Partitions• Production Line Supports• Trolley Systems• Wall Framing

B-Line’s Metal Framing system provides aneconomical solution for electrical, mechanicaland industrial supports with an unlimitedvariety of applications in the constructionindustry.

Metal Framing Electrical Applications• Lighting Fixture Supports• Raceway Systems• Trapeze Hangers• Pipe & Conduit Supports• Cable Tray Supports• Beam Adjustments

B 52

www.afielektrik.com

CONDUIT HANGERSBoru Ask› Aparatlar›