2
VITO-MRT Safe and reliable temperature measurement. The VITO family for temperature and water bottom measurement together with Honeywell Enraf tank gauges is the ultimate answer for your inventory control needs. As one of the first available products measuring the average product temperature in tank gauging applications, the Multiple Resistance Temperature devices (MRTs) consist of multiple resistor elements each having a different length. Depending on the liquid level measured by the level gauge, the longest element which is completely submerged is selected to represent the average temperature of your stored product. This technique still complies with all major industry recommendations. The VITO MRT opens up the opportunity to upgrade your tank gauging equipment without the need to instantly replace all your temperature elements. The intrinsically safe signals from the VITO MRT comply with all major safety requirements for use in hazardous areas.

EN-09-24-ENG

Embed Size (px)

DESCRIPTION

ingenieria tk

Citation preview

  • VITO-MRT

    Safe and reliable temperature measurement.The VITO family for temperature and water bottom measurement

    together with Honeywell Enraf tank gauges is the ultimate

    answer for your inventory control needs. As one of the fi rst

    available products measuring the average product temperature

    in tank gauging applications, the Multiple Resistance

    Temperature devices (MRTs) consist of multiple resistor elements

    each having a different length. Depending on the liquid level

    measured by the level gauge, the longest element which is completely submerged is selected

    to represent the average temperature of your stored product. This technique still complies with

    all major industry recommendations. The VITO MRT opens up the opportunity to upgrade your

    tank gauging equipment without the need to instantly replace all your temperature elements.

    The intrinsically safe signals from the VITO MRT comply with all major safety requirements for

    use in hazardous areas.

  • Dimensional drawing VITO Interface

    Identification code 762

    Exter nal gr ounding terminal

    Space needed to r emove cover

    Instrument Label

    T ag plate (optional )

    Cable entry

    118

    (4 5

    /8)

    2

    0 0 (7

    7/8

    )

    146 (5 3/4)

    Pr obe entry

    VITO MRT Interface 762Serial no: T est date:

    Pos 1 ApplicationU General purpose

    Pos 2 VersionR VITO interface for resistance measurement (MRT / RTD)

    Pos 3 Not used* Position not used

    Pos 4 Not used* Position not used

    Pos 5, 6, 7 Instrument designation7 6 2 VITO MRT Interface

    Pos 8 Not used* Position not used

    Pos 9 Probe entryA G 1/2 standard in boxB 3/4 NPT via reducer

    Pos 10 Cable entryG M20 x 1.5 standard in box (not if Pos 11 = F)N 3/4 NPT via reducerS PG 16 via reducer (not if Pos 11 = F)

    Pos 11 Safety approvalsA ATEX / IECEx Europe / GlobalF FM / CSA USA

    U R * * 7 6 2 * B N F Typical identification code

    R * * 7 6 2 * Your identification code

    EN-09-24-ENGAugust 2009 2009 Honeywell International Inc.

    For More InformationTo learn more about Honeywell Enrafssolutions, contact your Honeywell Enraf account manager or visit www.honeywellenraf.com.

    AmericasHoneywell Enraf Americas, Inc.2000 Northfield Ct.Roswell, GA 30076 USAPhone: +1 770 475 1900Email: [email protected]

    Europe, Middle East and AfricaHoneywell EnrafDelftechpark 392628 XJ DelftThe NetherlandsPhone: +31 (0)15 2701 100Email: [email protected]

    Asia PacificHoneywell Pte Ltd.17 Changi Business Park Central 1Singapore 486073Phone: +65 6355 2828Email: [email protected]