62
SMART power design

Enatel Limited - Product Catalogue 2010 v1.0

Embed Size (px)

DESCRIPTION

productos enatel

Citation preview

Page 1: Enatel Limited - Product Catalogue 2010 v1.0

SMART power design

Page 2: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | �

We are specialists in the design and manufacture of a range of standby power solutions for the telecom, networking, wireless and industrial markets. Enatel’s

smart power design offers intelligent solutions at an empowering price. In a market where only the fast survive, we respond quickly and cost-effectively so our

customers can do the same.

Offering a range of solutions from small standalone systems for applications like access nodes to medium systems for radio base stations for mobile networks and

larger systems for central office power applications. Our knowledge and experience of the global marketplace, along with our talented team, enable us to create

power supply solutions that meet each customer’s unique specifications no matter what volume they require.

We not only create our own suite of products, we also offer a comprehensive contract manufacturing service. Our highly flexible environment allows us to specialize

in small to medium volume as well as highly repetitive production.

AC-DC POWER SYSTEMS ..........................................................................4

1U MICRO COMPACT SYSTEM 0.8 - 2.4kW 48V DC .......................................5

1U ULTRA COMPACT SYSTEM 1.0 - 4.0kW 48V DC .......................................6

1U ULTRA COMPACT SYSTEM 1.0 - 4.0kW 48V DC .......................................7

2U ULTRA COMPACT SYSTEM 1.0 - 6.0kW 48V DC .......................................8

2U ULTRA COMPACT SYSTEM 1.0 - 6.0kW 48V DC .......................................9

2U ULTRA COMPACT SYSTEM 1.0 - 8.0kW 48V DC .....................................10

�U COMPACT SYSTEM 1.0 - 6.0kW 48V DC ..................................................11

�U COMPACT SYSTEM 1.0 - 6.0kW 48V DC ..................................................12

�U COMPACT SYSTEM 1.0 - 8.0kW 48V DC ..................................................1�

5U MAXI COMPACT SYSTEM 1.0 - 14.0kW 48V DC ......................................14

5U MAXI COMPACT SYSTEM 1.0 - 14.0kW 48V DC ......................................15

5U MAXI COMPACT SYSTEM 1.0 - 14.0kW 48V DC ......................................16

6U MAXI COMPACT SYSTEM 1.0 - 22.0kW 48V DC ......................................17

15U MEDIUM SYSTEM �.0 - 27.0kW 48V DC .................................................18

2.0M MEDIUM SYSTEM �.0 - 54.0kW 48V DC ................................................19

2.2M INTEGRATED BASE TRANSCEIVER

STATION SYSTEM 1.0 - 16.0kW 48V DC ........................................................20

1.6M MEDIUM SYSTEM �.0 - 27.0kW 48V DC ................................................21

2.0M LARGE DATA CENTER SOLUTIONS ......................................................22

WALL MOUNT SYSTEM 4.0kW 48V DC / 2.1kW 24V DC ...............................2�

MODULAR RECTIFIERS .............................................................................24

RM�048 �.0kW 48V DC MODULAR RECTIFIER ..............................................25

RM�048/24 �.0kW 48V DC / 1.7kW 24V DC MODULAR RECTIFIER ..............26

RM�060/48 �.0kW 60/48V DC MODULAR RECTIFIER ...................................27

RM2�24 2.�kW 24V DC MODULAR RECTIFIER ..............................................28

RM2048XP 2.0KW 48V DC MODULAR RECTIFIER .........................................29

RM2048/24 2.0kW 48V DC / 1.0kW 24V DC MODULAR RECTIFIER ..............�0

RM1860/48 1.8kW 60/48V DC MODULAR RECTIFIER ...................................�1

RM1048 1.0kW 48V DC MODULAR RECTIFIER ..............................................�2

RM848 800W 48V DC MODULAR RECTIFIER .................................................��

FLAT MOUNT RECTIFIERS .......................................................................�4

RF SERIES FLAT MOUNT RECTIFIERS ...........................................................�5

WALL MOUNT RECTIFIERS ......................................................................�6

RW SERIES WALL MOUNT RECTIFIERS ........................................................�7

DC-AC POWER SYSTEMS ........................................................................�8

DC-AC INVERTERS .....................................................................................�9

IM SERIES MODULAR INVERTERS .................................................................40

SBM SERIES STATIC BYPASS MODULE........................................................41

DC-DC CONVERTERS ................................................................................42

CM SERIES 1.7kW MODULAR DC-DC CONVERTERS ...................................4�

CM SERIES 500W to 1.0kW MODULAR DC-DC CONVERTERS ....................44

MONITORING ...............................................................................................45

SM�6 SUPERVISORY MODULE ......................................................................46

SM�5 SUPERVISORY MODULE ......................................................................47

SM�2 SUPERVISORY MODULE ......................................................................48

SM�1 SUPERVISORY MODULE ......................................................................49

SM11 SUPERVISORY MODULE ......................................................................50

FAN CONTROLLER BOARD ............................................................................50

BATTERY CONDITION MONITOR ...................................................................51

AC MAINS MONITOR .......................................................................................51

FTTX POWER SOLUTIONS........................................................................52

nSURE 1U MICRO COMPACT SYSTEM 0.8 - 2.4KW 48V DC ........................5�

nSURE NS�00-12 .............................................................................................54

nSURE NS�0-12 ...............................................................................................55

INDUSTRIAL SOLUTIONS .........................................................................56

2U ULTRA COMPACT SYSTEM �.0 - 6.0kW 110V DC ...................................57

WALL MOUNT BATTERY CHARGER �.0kW 110V DC ....................................58

RM�0110 �.0KW 110V DC MODULAR RECTIFIER .........................................59

SM�4 SUPERVISORY MODULE ......................................................................60

SM�� SUPERVISORY MODULE ......................................................................61

ENATEL | 2010 PRODUCT CATALOGUE

Page 3: Enatel Limited - Product Catalogue 2010 v1.0

4 | ENATEL | 2010 PRODUCT CATALOGUE

AC-DC POWER SYSTEMS

Our DC power systems are designed to meet the requirements of

telecommunications applications requiring high reliability and optimum

performance with easy expansion by way of hot pluggable modular rectifiers.

They are the ideal solution for powering telecommunications and data networks

requiring 24V, 48V or 60V DC. We offer a range of solutions for applications from

small standalone systems for applications like access nodes to medium sized

systems for radio base stations for mobile networks to larger systems for central

office power applications.

Systems are configured using Enatel’s state of the art high frequency switch

mode rectifier modules, intelligent network capable controllers, AC & DC

distribution modules, and cabinets, and can be customized and configured to

meet individual customer requirements.

For details on a Enatel power system that meets your requirements contact us.

- World leading power density.

- Fully featured telecom

grade rectifiers.

- Network monitoring available.

- Modular 19” design for ease

of installation.

- Includes AC surge protection.

- More room for revenue

creating equipment.

- Upgrade existing systems

to higher power.

- High reliability means less cost

of maintenance.

- Full remote monitoring available

means less site visits and less cost.

- Cost competitive.

- Suitable for more harsh

environments.

Page 4: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 5

48V nominal output voltage.

2.4kW maximum output power.

1U MICRO COMPACT SYSTEM 0.8 - 2.4kW 48V DC

AC Input: Single phase.

AC Current: 170V AC, 15.0A max. 230V AC, 11.1A nominal.

(refer to RM8xx, series brochures for full details)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full load)

Termination: Singlephase,1.5mflyinglead.

DC Output

Nominal Voltage: -48V

Rated System Output Power: 2400W max. (50A @ -48V; 44.4A @ -54.0V)

Polarity: Positive earth. (negative earth available to special order).

DC Distribution:

Load: 2x 10A, 2x 20A load circuit breakers.

Battery: 2x 30A battery circuit breakers.

Breaker Fail Detection: Electronic fail detection on both load and battery breakers.

DC Terminals (Front Connected):

Load: 6mm² push-in spring cage.

Battery: 55A power-pole plug-in connectors.

LowVoltageDisconnect: 50AbatteryLVD(magneticallylatching)fittedasstandard.

Mechanical

Dimensions,W,H,D: 482.6mm(standard19”module),alsofitsETSI515mmmountingcabinet,

44.45mm (1U, 1.75”), 285mm (11.6”)

Weight: 5kg(excludingrectifiermodules)

Shipping Dimensions, W,H,D: 540mm, 95mm, 400mm

Weight: 6kg(excludingrectifiermodules)

Monitoring & Control: Various monitoring options are available via the Enatel SM35/36 series

of control & supervisory modules. Standard features include full

temperature compensation, automated and manual battery testing/

equalisation, 6x general purpose inputs and 6x voltage-free relay alarm

outputs. For further details, refer to the SM35/36 series of brochures.

Accessories

ACA-BC08P2: 2m, 8mm Ø battery cable kit. (other lengths available to special order)

PartNumbers: Actualpartnumberswillvarywithconfiguration.

PSX1606211F-000: Microcompactsystem,2x800W48Vrectifiers,6xload

2x battery MCB’s, front termination, SM35 supervisory module.

PSX1606221F-000: Microcompactsystem,2x800W48Vrectifiers,6xload

2x battery MCB’s, front termination, SM36 supervisory module.

PSX2404211F-000: Microcompactsystem,3x800W48Vrectifiers,4xload

2x battery MCB’s, front termination, SM35 supervisory module.

PSX2404221F-000: Microcompactsystem,3x800W48Vrectifiers,4xload

2x battery MCB’s, front termination, SM36 supervisory module.

Supervisory ModuleSM36

RM848 RM848 RM848

Page 5: Enatel Limited - Product Catalogue 2010 v1.0

6 | ENATEL | 2010 PRODUCT CATALOGUE

48V nominal output voltage.

4.0kW maximum output power.

1U ULTRA COMPACT SYSTEM 1.0 - 4.0kW 48V DC

AC Input: Single phase. (refer to RM series brochures for full details)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full load)

Termination: Single phase, 10mm² L, N, E tunnel terminals.

DC Output

Nominal Voltage: -48V (+24V available to special order)

Rated System Output Power: 4000W @ -48V (2000W @ -48V. Low power option.)

Polarity: Positive earth. (negative earth available to special order)

DC Distribution:

Load: 1x 63A load circuit breaker.

(1x 50A load circuit breaker. Low power option.)

Battery: 1x 63A battery circuit breaker.

(1x 50A battery circuit breaker. Low power option.)

Breaker Fail Detection: Electronic fail detection on both load and battery breakers.

DC Terminals: Tunnel terminals, 10mm².

LowVoltageDisconnect: 80AbatteryLVDfittedasstandard.

(50AbatteryLVDfittedasstandard.Lowpoweroption.)

Mechanical

Dimensions, W, H, D: 482.6mm (standard 19” module), 44.45mm (1U, 1¾”), 350mm (13¾”)

Weight: 5kg(excludingrectifiermodules)

Shipping Dimensions, W, H, D: 540mm, 95mm, 400mm

Weight: 6kg(excludingrectifiermodules)

Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of

control & supervisory modules. Standard features include full temperature

compensation, automated and manual battery testing/equalisation and

three voltage-free relay alarm outputs. Options include extension I/O PCBs

that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free

relay outputs. For further details, refer to the SM30 series of brochures.

PartNumbers: Actualpartnumberswillvarywithconfiguration.

PSC04020110-000: 1U Ultra Compact System including standard SM31 supervisory module.

PSC04020111-000: 1U Ultra Compact System including standard

SM31 supervisory module and I/O expansion card.

PSC04020120-000: 1U Ultra Compact System including standard SM32 supervisory module.

PSC04020121-000: 1U Ultra Compact System including standard

SM32 supervisory module and I/O expansion card.

PSC02020110-000: Low Power 1U Ultra Compact System including standard

SM31 supervisory module.

PSC02020111-000: Low Power 1U Ultra Compact System including standard

SM31 supervisory module and I/O expansion card.

PSC02020120-000: Low Power 1U Ultra Compact System including standard

SM32 supervisory module.

PSC02020121-000: Low Power 1U Ultra Compact System including standard

SM32 supervisory module and I/O expansion card.

Supervisory ModuleSM32

ULTRAcompact

Load

Battery

Page 6: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 7

48V nominal output voltage.

4.0kW maximum output power.

1U ULTRA COMPACT SYSTEM 1.0 - 4.0kW 48V DC

AC Input: Single phase. (refer to RM series brochures for full details)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full load)

Termination: Single phase, 6mm² L, N, E tunnel terminals.

DC Output

Nominal Voltage: -48V, -60V (+24V available to special order)

Rated System Output Power: 4000W @ -48V (2000W @ -48V. Low power option.)

Polarity: Positive earth. (negative earth available to special order)

DC Distribution:

Load: 3x 20A load circuit breakers.

(3x 10A load circuit breakers. Low power option.)

Battery: 2x 30A battery circuit breakers.

(2x 20A battery circuit breakers. Low power option.)

Breaker Fail Detection: Electronic fail detection on both load and battery breakers.

DC Terminals:

Live: Tunnel terminals, 6mm²

Common: Tunnel terminals, 6mm²

LowVoltageDisconnect: 80AbatteryLVDfittedasstandard.

(50AbatteryLVDfittedasstandard.Lowpoweroption.)

Mechanical

Dimensions, W, H, D: 482.6mm (standard 19” module), 44.45mm (1U, 1¾”), 350mm (13¾”)

Weight: 5kg(excludingrectifiermodules)

Shipping Dimensions, W, H, D: 540mm, 95mm, 400mm

Weight: 6kg(excludingrectifiermodules)

Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of

control & supervisory modules. Standard features include full temperature

compensation, automated and manual battery testing/equalisation and

three voltage-free relay alarm outputs. Options include extension I/O PCBs

that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free

relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: Actual part numbers will vary with congifuration.

PSC04020110-100: 1U Ultra Compact System including standard SM31 supervisory module.

PSC04020111-100: 1U Ultra Compact System including standard SM31

supervisory module and I/O expansion card.

PSC04020120-100: 1U Ultra Compact System including standard SM32 supervisory module.

PSC04020121-100: 1U Ultra Compact System including standard SM32

supervisory module and I/O expansion card.

PSC02020110-100: Low Power 1U Ultra Compact System including standard

SM31 supervisory module.

PSC02020111-100: Low Power 1U Ultra Compact System including standard

SM31 supervisory module and I/O expansion card.

PSC02020120-100: Low Power 1U Ultra Compact System including standard

SM32 supervisory module.

PSC02020121-100: Low Power 1U Ultra Compact System including standard

SM32 supervisory module and I/O expansion card.

Supervisory ModuleSM32

ULTRAcompact

Page 7: Enatel Limited - Product Catalogue 2010 v1.0

8 | ENATEL | 2010 PRODUCT CATALOGUE

48V nominal output voltage.

6.0kW maximum output power.

2U ULTRA COMPACT SYSTEM 1.0 - 6.0kW 48V DC

AC Input: Three phase or single phase. (refer to RM series brochures for full details)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full load)

Termination: Three phase, 6mm² L1, L2, L3, N, E tunnel terminals.

(Single phase by linking L1, L2, L3 terminals)

DC Output

Nominal Voltage: -48V, -60V (+24V available to special order)

Rated System Output Power: 6000W @ -48V (3000W @ -48V. Low power option)

Polarity: Positive earth. (negative earth available to special order)

DC Distribution:

Load: 2x 10A, 2x 20A, 2x 32A load circuit breakers.

(2x 6A, 2x 10A, 2x 20A load circuit breakers. Low power option.)

Battery: 2x 63A battery circuit breakers.

(2x 63A battery circuit breakers. Low power option.)

Breaker Fail Detection: Electronic fail detection on both load and battery breakers.

DC Terminals:

Load: Tunnel terminals, 16mm² (rear connected)

Battery: Tunnel terminals, 35mm² (rear connected)

LowVoltageDisconnect: 125AbatteryLVDfittedasstandard.(magneticallylatchingcontactor)

(80AbatteryLVDfittedasstandard.Lowpoweroption)

Mechanical

Dimensions, W, H, D: 482.6mm (standard 19” module), 89mm (2U, 3½”),

350mm (13¾”) (390mm with cable strain relief)

Weight: 9kg(excludingrectifiermodules)

Shipping Dimensions, W, H, D: 540mm, 150mm, 435mm

Weight: 10.5kg(excludingrectifiermodules)

Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of

control & supervisory modules. Standard features include full temperature

compensation, automated and manual battery testing/equalisation and

three voltage-free relay alarm outputs. Options include extension I/O PCBs

that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free

relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: Actual part numbers will vary with congifuration.

PSC06030210-000: 2U Ultra Compact System including standard SM31 supervisory module.

PSC06030211-000: 2U Ultra Compact System including standard SM31

supervisory module and I/O expansion card.

PSC06030220-000: 2U Ultra Compact System including standard SM32 supervisory module.

PSC06030221-000: 2U Ultra Compact System including standard SM32

supervisory module and I/O expansion card.

PSC03030210-000: Low Power 2U Ultra Compact System including standard

SM31 supervisory module.

PSC03030211-000: Low Power 2U Ultra Compact System including standard

SM31 supervisory module and I/O expansion card.

PSC03030220-000: Low Power 2U Ultra Compact System including standard

SM32 supervisory module.

PSC03030221-000: Low Power 2U Ultra Compact System including standard

SM32 supervisory module and I/O expansion card.

Supervisory ModuleSM32

ULTRAcompact

1Battery

2

5Load

6

3Load

4

1Load

2

Page 8: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 9

48V nominal output voltage.

6.0kW maximum output power.

2U ULTRA COMPACT SYSTEM 1.0 - 6.0kW 48V DC

AC Input: Three phase or single phase. (refer to RM series brochures for full details)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full load)

Termination: Three phase, 6mm² L1, L2, L3, N, E tunnel terminals.

(Single phase by linking L1, L2, L3 terminals)

DC Output

Nominal Voltage: -48V, -60V (+24V available to special order)

Rated System Output Power: 6000W @ -48V (3000W @ -48V. Low power option.)

Polarity: Positive earth. (negative earth available to special order)

DC Distribution:

Load: 8x 10A, 4x 20A, 4x 30A load circuit breakers.

(8x 6A, 4x 10A, 4x 20A load circuit breakers. Low power option.)

Battery: 2x 100A battery circuit breakers.

(2x 50A battery circuit breakers. Low power option.)

Breaker Fail Detection: Electronic fail detection on both load and battery. breakers

DC Terminals (rear connected):

Load: 10A, 6mm² tunnel terminals. 20A & 30A, 10mm² tunnel terminals.

(6A & 10A, 6mm² tunnel terminals.

20A, 10mm² tunnel terminals. Low power option.)

Battery: 100A, 35mm² tunnel terminals.

(50A, 16mm² tunnel terminals. Low power option.)

LowVoltageDisconnect: 125AbatteryLVDfittedasstandard.

(80AbatteryLVDfittedasstandard.Lowpoweroption.)

Mechanical

Dimensions, W, H, D: 482.6mm (standard 19” module), 89mm (2U, 3½”),

350mm (13¾”) (390mm with cable strain relief)

Weight: 9kg(excludingrectifiermodules)

Shipping Dimensions, W, H, D: 540mm, 150mm, 435mm

Weight: 10.5kg(excludingrectifiermodules)

Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of

control & supervisory modules. Standard features include full temperature

compensation, automated and manual battery testing/equalisation and

three voltage-free relay alarm outputs. Options include extension I/O PCBs

that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free

relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: Actual part numbers will vary with congifuration.

PSC06030210-100: 2U Ultra Compact System including standard SM31 supervisory module.

PSC06030211-100: 2U Ultra Compact System including standard SM31

supervisory module and I/O expansion card.

PSC06030220-100: 2U Ultra Compact System including standard SM32 supervisory module.

PSC06030221-100: 2U Ultra Compact System including standard SM32

supervisory module and I/O expansion card.

PSC03030210-100: Low Power 2U Ultra Compact System including standard

SM31 supervisory module.

PSC03030211-100: Low Power 2U Ultra Compact System including standard

SM31 supervisory module and I/O expansion card.

PSC03030220-100: Low Power 2U Ultra Compact System including standard

SM32 supervisory module.

PSC03030221-100: Low Power 2U Ultra Compact System including standard

SM32 supervisory module and I/O expansion card.

Supervisory ModuleSM32

ULTRAcompact

1Battery

2

Page 9: Enatel Limited - Product Catalogue 2010 v1.0

10 | ENATEL | 2010 PRODUCT CATALOGUE

48V nominal output voltage.

8.0kW maximum output power.

2U ULTRA COMPACT SYSTEM 1.0 - 8.0kW 48V DC

AC Input: Three phase or single phase. (refer to RM series brochures for full details)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full load)

Termination: Three phase, 10mm² L1, L2, L3, N tunnel terminals,

16mm² E tunnel terminal. (Single phase by linking L1, L2, L3 terminals)

DC Output

Nominal Voltage: -48V, -60V (+24V available to special order)

Rated System Output Power: 8000W @ -48V

Polarity: Positive earth. (negative earth available to special order)

DC Distribution:

Load: 2x 20A, 2x 63A load circuit breakers.

Battery: 2x 100A battery circuit breakers.

Breaker Fail Detection: Electronic fail detection for load breakers.

Auxiliaries for battery MCB fail detection.

DC Terminals:

Load: Tunnel terminals, 16mm² (rear connected)

Battery: Tunnel terminals, 35mm² (rear connected)

LowVoltageDisconnect: 150AbatteryLVDfittedasstandard.(magneticallylatchingcontactor)

Mechanical

Dimensions, W, H, D: 482.6mm (standard 19” module), 89mm (2U, 3½”),

350mm (13¾”) (390mm with cable strain relief)

Weight: 9kg(excludingrectifiermodules)

Shipping Dimensions, W, H, D: 483mm, 88.9mm, 350mm

Weight: 10.5kg(excludingrectifiermodules)

Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of

control & supervisory modules. Standard features include full temperature

compensation, automated and manual battery testing/equalisation and

three voltage-free relay alarm outputs. Options include extension I/O PCBs

that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free

relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: Actual part numbers will vary with congifuration.

PSC08040210-000: 2U Ultra Compact System including standard SM31 supervisory module.

PSC08040211-000: 2U Ultra Compact System including standard SM31

supervisory module and I/O expansion card.

PSC08040220-000: 2U Ultra Compact System including standard SM32 supervisory module.

PSC08040221-000: 2U Ultra Compact System including standard SM32

supervisory module and I/O expansion card.

Supervisory ModuleSM32

ULTRAcompact

3Load

4

1Load

2

1Battery

2

Page 10: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 11

48V nominal output voltage.

6.0kW maximum output power.

�U COMPACT SYSTEM 1.0 - 6.0kW 48V DC

AC Input: Three phase or single phase. (refer to RM series brochures for full details)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full load)

Termination: Three phase L1, L2, L3, N, E 10mm² terminal blocks.

(Single phase by linking line terminals)

DC Output

Nominal Voltage: -48V, -60V (+24V available to special order)

Rated System Output Power: 6000W @ -48V

Polarity: Positive earth. (negative earth available to special order)

DC Distribution:

Load: 4x 10A, 4x 20A, 4x 32A load circuit breakers.

Battery: 2x 100A battery circuit breakers.

Breaker Fail Detection: Electronic fail detection on both load and battery breakers.

DC Terminals (rear connected):

Load: 16mm² tunnel terminals.

Battery: 35mm² tunnel terminals.

LowVoltageDisconnect: 125AbatteryLVDfittedasstandard.

Mechanical

Dimensions, W, H, D: 482.6mm (standard 19” module), 133.3mm (3U, 5¼”),

350mm (13¾”) (390mm with cable strain relief)

Weight: 11kg(excludingrectifiermodules)

Shipping Dimensions, W, H, D: 540mm, 200mm, 435mm

Weight: 14kg(excludingrectifiermodules)

Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of

control & supervisory modules. Standard features include full temperature

compensation, automated and manual battery testing/equalisation and

three voltage-free relay alarm outputs. Options include extension I/O PCBs

that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free

relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: Actual part numbers will vary with congifuration.

PSC06030310-000: 3U Compact System including standard SM31 supervisory module.

PSC06030311-000: 3U Compact System including standard SM31

supervisory module and I/O expansion card.

PSC06030320-000: 3U Compact System including standard SM32 supervisory module.

PSC06030321-000: 3U Compact System including standard SM32

supervisory module and I/O expansion card.

4

3

2

1

8

7

6

5

Load

12

11

10

9

Load

2

1

Battery

Supervisory ModuleSM32

3U Compact System

Page 11: Enatel Limited - Product Catalogue 2010 v1.0

12 | ENATEL | 2010 PRODUCT CATALOGUE

48V nominal output voltage.

6.0kW maximum output power.

�U COMPACT SYSTEM 1.0 - 6.0kW 48V DC

AC Input: Three phase or single phase. (refer to RM series brochures for full details)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full load)

Termination: Three phase L1, L2, L3, N, E 6mm2 terminal blocks.

(Single phase by linking line terminals)

Proctection: 20Acircuitbreakerprovidedperrectifier.

DC Output

Nominal Voltage: -48V, -60V (+24V available to special order)

Rated System Output Power: 6000W @ -48V

Polarity: Positive earth. (negative earth available to special order)

DC Distribution:

Load: 5x 10A, 4x 20A, 4x 32A load circuit breakers.

Battery: 2x 100A battery circuit breakers.

Breaker Fail Detection: Electronic fail detection on both load and battery breakers.

DC Terminals (rear connected):

Load: 10A, 6mm² tunnel terminals.

32A, 10mm² tunnel terminals.

50A, 16mm² tunnel terminals.

Battery: 35mm² tunnel terminals.

LowVoltageDisconnect: 125AbatteryLVDfittedasstandard.

Mechanical

Dimensions, W, H, D: 482.6mm (standard 19” module), 133.3mm (3U, 5¼”),

350mm (13¾”) (390mm with cable strain relief)

Weight: 11.5kg(excludingrectifiermodules)

Shipping Dimensions, W, H, D: 540mm, 200mm, 435mm

Weight: 14.5kg(excludingrectifiermodules)

Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of

control & supervisory modules. Standard features include full temperature

compensation, automated and manual battery testing/equalisation and

three voltage-free relay alarm outputs. Options include extension I/O PCBs

that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free

relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: Actual part numbers will vary with congifuration.

PSC06030310-200: 3U Compact System including standard SM31 supervisory module.

PSC06030311-200: 3U Compact System including standard SM31

supervisory module and I/O expansion card.

PSC06030320-200: 3U Compact System including standard SM32

supervisory module.

PSC06030321-200: 3U Compact System including standard SM32

supervisory module and I/O expansion card.

3U Compact System

11

12

13

14

15

10

5

6

7

8

9

4

2

3

1

2

3

1

Load

Rectifiers

ACInput

2

1Battery

Supervisory ModuleSM32

LoadLoad

Page 12: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 1�

48V nominal output voltage.

8.0kW maximum output power.

�U COMPACT SYSTEM 1.0 - 8.0kW 48V DC

AC Input: Three phase or single phase. (refer to RM series brochures for full details)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full load)

Termination: Single phase L, N, E 16mm² terminal blocks

Single phase surge protection. (40KA 8/20µsec)

(Three phase without surge protection available to special order)

DC Output

Nominal Voltage: -48V, -60V (+24V available to special order)

Rated System Output Power: 8000W @ -48V

Polarity: Positive earth. (negative earth available to special order)

DC Distribution:

Load: 2x 10A, 2x 20A, 4x 32A load circuit breakers.

Battery: 2x 100A battery circuit breakers.

Breaker Fail Detection: Electronic fail detection on both load and battery breakers.

DC Terminals (rear connected):

Load: 16mm² tunnel terminals.

Battery: 35mm² tunnel terminals.

LowVoltageDisconnect: 150AbatteryLVDfittedasstandard.

Mechanical

Dimensions, W, H, D: 482.6mm (standard 19” module), 133.3mm (3U, 5¼”),

350mm (13¾”) (390mm with cable strain relief)

Weight: 11kg(excludingrectifiermodules)

Shipping Dimensions, W, H, D: 483mm, 133.35mm, 350mm

Weight: 11.5kg(excludingrectifiermodules)

Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of

control & supervisory modules. Standard features include full temperature

compensation, automated and manual battery testing/equalisation and

three voltage-free relay alarm outputs. Options include extension I/O PCBs

that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free

relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: Actual part numbers will vary with congifuration.

PSC08040310-000: 3U Compact System including standard SM31 supervisory module.

PSC08040311-000: 3U Compact System including standard SM31

supervisory module and I/O expansion card.

PSC08040320-000: 3U Compact System including standard SM32

supervisory module.

PSC08040321-000: 3U Compact System including standard SM32

supervisory module and I/O expansion card.

4

3

2

1

8

7

6

5

Load

2

1

Battery

Supervisory ModuleSM32 3U Compact System

ACInput

Input MCB

SPD

Page 13: Enatel Limited - Product Catalogue 2010 v1.0

14 | ENATEL | 2010 PRODUCT CATALOGUE

48V nominal output voltage.

14.0kW maximum output power.

5U MAXI COMPACT SYSTEM 1.0 - 14.0kW 48V DC

AC Input: Three phase (refer to RM series brochures for full details)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full load)

Termination: Three phase L1, L2, L3, N, E 10mm² terminal blocks.

Surge protection. (40kA 8/20msec)

DC Output

Nominal Voltage: -48V, -60V (+24V available to special order)

Rated System Output Power: 14000W @ -48V DC

Polarity: Positive earth. (negative earth available to special order)

DC Distribution:

Load: 2x 10A, 6x 32A, 2x 50A load circuit breakers.

Battery: 4x 100A battery circuit breakers.

Breaker Fail Detection: Electronic fail detection on both load and battery breakers.

DC Terminals (rear connected):

Load: 16mm² tunnel terminals.

Battery: 35mm² tunnel terminals.

LowVoltageDisconnect: 300AbatteryLVDfittedasstandard.

Mechanical

Dimensions, W, H, D: 482.6mm (standard 19” module), 222.2mm (5U, 8¾”),

350mm (13¾”) (390mm with cable strain relief)

Weight: 14kg(excludingrectifiermodules)

Shipping Dimensions, W, H, D: 540mm, 350mm, 435mm

Weight: 18kg(excludingrectifiermodules)

Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of

control & supervisory modules. Standard features include full temperature

compensation, automated and manual battery testing/equalisation and

three voltage-free relay alarm outputs. Options include extension I/O PCBs

that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-

free relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: Actual part numbers will vary with congifuration.

PSC12070510-000: 5U Maxi Compact System including standard SM31 supervisory module.

PSC12070511-000: 5U Maxi Compact System including standard SM31

supervisory module and I/O expansion card.

PSC12070520-000: 5U Maxi Compact System including standard SM32 supervisory module.

PSC12070521-000: 5U Maxi Compact System including standard SM32

supervisory module and I/O expansion card.

1 2

Battery

43Load

10987654321AC Input

5U Compact System

Supervisory ModuleSM32

Page 14: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 15

5U Compact System

10987654321 18

Load

171615141312111 2

Battery

43

Supervisory ModuleSM32

48V nominal output voltage.

14.0kW maximum output power.

5U MAXI COMPACT SYSTEM 1.0 - 14.0kW 48V DC

AC Input: Three phase. (refer to RM series brochures for full details)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full load)

Termination: Three phase L1, L2, L3, N, E 16mm² terminal blocks.

DC Output

Nominal Voltage: -48V, -60V (+24V available to special order)

Rated System Output Power: 14000W @ -48V

Polarity: Positive earth. (negative earth available to special order)

DC Distribution:

Load: 6x 10A, 4x 20A, 4x 32A, 4x 50A load circuit breakers.

Battery: 4x 100A battery circuit breakers.

Breaker Fail Detection: Electronic fail detection on both load and battery breakers.

DC Terminals:

Load: 16mm² tunnel terminals.

Battery: 35mm² tunnel terminals.

LowVoltageDisconnect: 300AbatteryLVDfittedasstandard.(option2xLVDs)

Mechanical

Dimensions, W, H, D: 482.6mm (standard 19” module), 222.2mm (5U, 8¾”),

350mm (13¾”) (390mm with cable strain relief)

Weight: 14kg(excludingrectifiermodules)

Shipping Dimensions, W, H, D: 540mm, 350mm, 435mm

Weight: 18kg(excludingrectifiermodules)

Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of

control & supervisory modules. Standard features include full temperature

compensation, automated and manual battery testing/equalisation and

three voltage-free relay alarm outputs. Options include extension I/O PCBs

that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free

relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: Actual part numbers will vary with congifuration.

PSC12070510-001: 5U Maxi Compact System including standard SM31 supervisory module.

PSC12070511-001: 5U Maxi Compact System including standard SM31

supervisory module and I/O expansion card.

PSC12070520-001: 5U Maxi Compact System including standard SM32 supervisory module.

PSC12070521-001: 5U Maxi Compact System including standard SM32

supervisory module and I/O expansion card.

Page 15: Enatel Limited - Product Catalogue 2010 v1.0

16 | ENATEL | 2010 PRODUCT CATALOGUE

48V nominal output voltage.

14.0kW maximum output power.

5U MAXI COMPACT SYSTEM 1.0 - 14.0kW 48V DC

AC Input: Three phase (refer to RM series brochures for full details)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full load)

Termination: Three phase L1, L2, L3, N, E, 16mm² terminal blocks

DC Output

Nominal Voltage: -48V, -60V (+24V available to special order)

Rated System Output Power: 14000W @ -48V

Polarity: Positive earth (negative earth available to special order)

DC Distribution:

Load: 6x 10A, 4x 20A, 6x 32A, 4x 50A load circuit breakers

Battery: 4x 100A battery circuit breakers

Breaker Fail Detection: Electronic fail detection on both load and battery breakers

DC Terminals:

Load: 16mm² tunnel terminals

Battery: 35mm² tunnel terminals

LowVoltageDisconnect: 300AbatteryLVDfittedasstandard

Mechanical

Dimensions, W, H, D: 482.6mm (standard 19” module), 222.2mm (5U, 8¾”),

350mm (13¾”) (390mm with cable strain relief)

Weight: 15kg(excludingrectifiermodules)

Shipping Dimensions, W, H, D: 540mm, 350mm, 435mm

Weight: 18kg(excludingrectifiermodules)

Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of

control & supervisory modules. Standard features include full temperature

compensation, automated and manual battery testing/equalisation and

three voltage-free relay alarm outputs. Options include extension I/O PCBs

that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free

relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: Actual part numbers will vary with congifuration.

PSC12070510-200: 5U Maxi Compact System including standard SM31 supervisory module.

PSC12070511-200: 5U Maxi Compact System including standard SM31

supervisory module and I/O expansion card.

PSC12070520-200: 5U Maxi Compact System including standard SM32 supervisory module.

PSC12070521-200: 5U Maxi Compact System including standard SM32

supervisory module and I/O expansion card.

Supervisory ModuleSM32

1 2

Battery

43

AC Input 19181716151413121110987654321 20

Load

5U Compact System

Page 16: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 17

Supervisory ModuleSM32

6U Compact System

1 2

Battery

43Load

10987654321AC Input

48V nominal output voltage.

22.0kW maximum output power.

6U MAXI COMPACT SYSTEM 1.0 - 22.0kW 48V DC

AC Input: Three phase. (refer to RM series brochures for full details)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full load)

Termination: Three phase L1, L2, L3, N, E 10mm² terminal blocks.

Surge protection. (40kA 8/20msec)

DC Output

Nominal Voltage: -48V, -60V (+24V available to special order)

Rated System Output Power: 22000W @ -48V DC

Polarity: Positive earth. (negative earth available to special order)

DC Distribution:

Load: 2x 20A, 4x 32A, 4x 63A load circuit breakers.

Battery: 4x 100A battery circuit breakers.

Breaker Fail Detection: Electronic fail detection on both load and battery breakers.

DC Terminals (rear connected):

Load: 20A, 32A, 63A, 16mm² tunnel terminals.

Battery: 35mm² tunnel terminals.

LowVoltageDisconnect: 500AbatteryLVDfittedasstandard.

Mechanical

Dimensions, W, H, D: 482.6mm (standard 19” module), 266.7mm (6U, 10½”),

350mm (13¾”) (390mm with cable strain relief)

Weight: 21kg(excludingrectifiermodules)

Shipping Dimensions, W, H, D: 540mm, 350mm, 435mm

Weight: 30kg(excludingrectifiermodules)

Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of

control & supervisory modules. Standard features include full temperature

compensation, automated and manual battery testing/equalisation and

three voltage-free relay alarm outputs. Options include extension I/O PCBs

that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free

relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: Actual part numbers will vary with congifuration.

PSC22110610-000: 6U Maxi Compact System including standard SM31 supervisory module.

PSC22110611-000: 6U Maxi Compact System including standard SM31

supervisory module and I/O expansion card.

PSC22110620-000: 6U Maxi Compact System including standard SM32 supervisory module.

PSC22110621-000: 6U Maxi Compact System including standard SM32

supervisory module and I/O expansion card.

PSC22110610-F00: 6U Front Terminal Maxi Compact System including standard

SM31 supervisory module.*

PSC22110611-F00: 6U Front Terminal Maxi Compact System including standard

SM31 supervisory module and I/O expansion card.*

PSC22110620-F00: 6U Front Terminal Maxi Compact System including standard

SM32 supervisory module.*

PSC22110621-F00: 6U Front Terminal Maxi Compact System including standard

SM32 supervisory module and I/O expansion card.*

*for front terminal systems a minimum of 3U height above

the 6U system is recommended for load and battery cabling.

Page 17: Enatel Limited - Product Catalogue 2010 v1.0

18 | ENATEL | 2010 PRODUCT CATALOGUE

48V nominal output voltage.

27.0kW maximum output power.

15U MEDIUM SYSTEM �.0 - 27.0kW 48V DC

AC Input

AC Input Range: 312-500V AC (full power output)

156-312V AC (reduced output power)

Maximum Input Current: 60A/ph (ph-N)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full power)

Style: 3-phase neutral and earth.

Surge Protection: MOV; 3x Ph-N, 1x N-Earth.

In(8/20µS): 20kA

Imax(8/20µS): 40kA

DC Output

Nominal System Output Voltage: -48V

Maximum Power Output: 27000W

Polarity: Positive earth. (standard)

Load & Battery Distribution: 16x load positions for 18mm wide circuit breakers,

plus 4x battery breakers up to 125A each.

Maybearrangedindifferentconfigurationsofloadandbattery

breakers. Fuse options also available. (options)

LowVoltageDisconnectOptions: SinglebatteryLVDfittedasstandard.

Up to 2x LVDs with independent control may

befittedonbatteryorloadside.(option)

LVD Current Rating: 600A

Supervisory & Monitoring Module: SM31 (standard) SM32 TCP/IP enabled for

webbasedviewing&configuration.(option)

Supervisory Module Mounting: Door mounted for improved system terminal access.

Battery Condition Monitoring: Optional full battery monobloc monitoring.

(bloc voltage & string current)

Alarms(voltagefreecontacts): 1xfixedalarm-“Monitorfailed”

Upto9xuserconfigurable,2ofwhicharepre-programmed:

- Non-urgent summary alarm

- Urgent summary alarm

7x unassigned, may be assigned to any one of 37 alarm events,

(e.g.rectifierfail,mainsfailetc.)onan“AND”or“OR”basis

Contacts rated for 1A at 60V DC

Environmental Requirements

Temperature: -10°C to +70°C (max. power de-rated above 50°C)

Humidity: 5-95% RH (non-condensing)

Altitude: <2500m, De-rate maximum ambient temperature

by 4°C per 1000m above sea level.

Mechanical

Dimensions W, D, H: 600mm (23 ½”) , 19” standard mounting rails 450mm (17 ¾”),

800mm (31 ½”) providing 15U of rack space.

Weight: 75kg (approx)

Shipping Size L, W, H 900mm x 700mm x 550mm

Shipping weight: 80kg (approx)

Compliances

Safety: EN60950

Part Numbers: Actual part numbers will vary with congifuration.

Contact us for further details on a solution that suits your requirements.

Page 18: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 19

48V nominal output voltage.

27.0kW maximum output power.

1.6M MEDIUM SYSTEM �.0 - 27.0kW 48V DC

AC Input

AC Input Range: 312-500V AC (full power output)

156-312V AC (reduced output power)

Maximum Input Current: 54A/ph (ph-N)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full power)

Style: 3-phase neutral and earth.

Surge Protection: MOV; 3x Ph-N, 1x N-Earth. (spark gap)

In(8/20µS): 20kA

Imax(8/20µS): 40kA

DC Output

Nominal System Output Voltage: -48V

Maximum Power Output: 27000W

Polarity: Positive earth. (standard)

Load Distribution:

Priority: 6x 18mm MCBs.

Non-Priority: 5x 18mm MCBs, 2x 100A DIN00 fuses, 2x 160A DIN00 fuses.

Battery Distribution: 2x 400A DIN02 fuses.

LVD Options: 2x LVDs with independent control on load side.

LVD Rating:

Priority: 400A

Non-Priority: 200A

Supervisory & Monitoring Module: SM31 (standard) SM32 TCP/IP enabled for

webbasedviewing&configuration.(option)

Supervisory Module Mounting: Door mounted for improved system terminal access.

Battery Condition Monitoring: Optional full battery monobloc monitoring.

(bloc voltage & string current)

Alarms(voltagefreecontacts): 1xfixedalarm–“Monitorfailed”

Upto9xuserconfigurable,2ofwhicharepre-programmed:

- Non-urgent summary alarm

- Urgent summary alarm

7x unassigned, may be assigned to any one of 37 alarm events,

(e.g.rectifierfail,mainsfailetc.)onan“AND”or“OR”basis.

Contacts rated for 1A at 60V DC

Environmental Requirements

Temperature: -10°C to +70°C (max. power de-rated above 50°C)

Humidity: 5-95% RH (non-condensing)

Altitude: <2500m, De-rate maximum ambient temperature

by 4°C per 1000m above sea level.

Mechanical

Dimensions W, D, H: 600mm (23.6”), 600mm (23.6”), 1600mm (63”),

providing 33U of rack space.

Weight: 120kg (approx)

Shipping Size L, W, H 1700mm x 720mm x 830mm

Shipping weight: 130kg (approx)

Compliances

Safety: EN60950

Part Numbers: Actual part numbers will vary with congifuration.

Contact us for further details on a solution that suits your requirements.

Page 19: Enatel Limited - Product Catalogue 2010 v1.0

20 | ENATEL | 2010 PRODUCT CATALOGUE

48V nominal output voltage.

54.0kW maximum output power.

2.0M MEDIUM SYSTEM �.0 - 54.0kW 48V DC

AC Input

Voltage Range: 312-500V AC (full power output)

156-312V AC (reduced output power)

Maximum Input Current: 120A/ph (ph-N)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full power)

Style: 3-phase neutral and earth.

Surge Protection: MOV; 3x Ph-N, 1x N-Earth.

In(8/20µS): 20kA

Imax(8/20µS): 40kA

DC Output

Nominal System Output Voltage: -48V

Maximum Power Output: 54000W

Polarity: Positive earth. (standard)

Load & Battery Distribution: 56x positions for 18mm wide DIN rail mount circuit breakers.

Maybearrangedinmanyconfigurationsofloadsandbatteries.

Fuse options also available. (options)

LowVoltageDisconnectOptions: SinglebatteryLVDfittedasstandard.

Up to 2x LVDs with independent control

maybefittedonbatteryorloadside.(option)

LVD Current Rating: 1200A

Supervisory & Monitoring Module: SM31 (standard) SM32 TCP/IP enabled

forwebbasedviewing&configuration.(option)

Supervisory Module Mounting: Door mounted for improved system terminal access.

Battery Condition Monitoring: Optional full battery monobloc monitoring.

(bloc voltage & string current)

Alarms(voltagefreecontacts): 1xfixedalarm–“Monitorfailed”

Upto9xuserconfigurable,2ofwhicharepre-programmed:

- Non-urgent summary alarm

- Urgent summary alarm

7x unassigned, may be assigned to any one of 37 alarm events,

(e.g.rectifierfail,mainsfailetc.)onan“AND”or“OR”basis

Contacts rated for 1A at 60V DC

Environmental Requirements

Temperature: -10°C to +70°C (max. power de-rated above 50°C)

Humidity: 5-95% RH (non-condensing)

Altitude: <2500m, De-rate maximum ambient temperature

by 4°C per 1000m above sea level.

Mechanical

Dimensions W, D, H: 600mm (23.6”), 19” standard mounting rails, 600mm (23.6”),

2000mm (78 ¾”) 40U of rack space.

Weight: 180kg (approx)

Shipping Size L, W, H 2100mm, 720mm, 830mm

Shipping weight: 195kg (approx)

Compliances

Safety: EN60950

Part Numbers: Actual part numbers will vary with congifuration.

Contact us for further details on a solution that suits your requirements.

Page 20: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 21

48V nominal output voltage.

16.0kW maximum output power.

2.2M INTEGRATED BASE TRANSCEIVER STATION SYSTEM 1.0 - 16.0kW 48V DC

AC Input

AC Input Range: 312-500V AC (full power output)

156-312V AC (reduced output power)

Maximum Input Current: 36A/ph (ph-N)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full power)

Style: 3-phase neutral and earth.

Surge Protection: MOV; 3x Ph-N, 1x N-Earth. (spark gap)

In(8/20µS): 20kA

Imax(8/20µS): 40kA

DC Output

Nominal System Output Voltage: -48V

Maximum Power Output: 16000W

Polarity: Positive earth. (standard)

Load & Battery Distribution: 24x load positions for 18mm wide circuit breakers, plus 3x battery

breakers up to 100A each. May be arranged in different

configurationsofloadandbatterybreakers.(option)

LowVoltageDisconnectOptions: SinglebatteryLVDfittedasstandard.Upto2xLVDswith

independentcontrolmaybefittedonloadside.(option)

LVD Current Rating: 400A

Supervisory & Monitoring Module: SM31 (standard) SM32 TCP/IP enabled

forwebbasedviewing&configuration.(option)

Supervisory Module Mounting: Door mounted for improved system terminal access.

RectifierModules: RM2048,48V2.0kWmodule.

Environmental Requirements

Temperature: -10°C to +70°C (max. power de-rated above 50°C)

Humidity: 5-95% RH (non-condensing)

Altitude: <2500m, De-rate maximum ambient temperature

by 4°C per 1000m above sea level.

Mechanical

Dimensions W, D, H: 600mm (23.6”), 600mm (23.6”),2200mm (86.6”)

Weight: 1000kgwhenfittedwith4xstringsof180Ahrbatteries.(approx)

Shipping Size L, W, H 2400mm x 720mm x 830mm

Shippingweight: 180kg(nobatteriesfitted,approx)

Battery Accommodation

Battery Trays: Up to 4x 180Ahr monoblocs of up to 60kg each per tray.

(max. of 250kg per tray)

Battery Monobloc Size W, D, H: 110mm, 555mm, 288mm

Compliances

Safety: EN60950

Part Numbers: Actual part numbers will vary with congifuration.

Contact us for further details on a solution that suits your requirements.

Page 21: Enatel Limited - Product Catalogue 2010 v1.0

22 | ENATEL | 2010 PRODUCT CATALOGUE

AC InputVoltage Range: 312-500V AC (full power output) 156-312V AC (reduced output power)Maximum Input Current: 120A/ph (ph-N)Frequency Range: 45-66HzPower Factor: >0.99 (full power)Style: 3-phase neutral and earth. Surge Protection: MOV; 3x Ph-N, 1x N-Earth. In(8/20µS): 20kA Imax(8/20µS): 40kA

DC OutputNominal System Output Voltage: -48V Maximum Power Output: From 54000W scalable to over 300kW.Polarity: Positive earth. (standard)

Load & Battery Distribution: 56x positions for 18mm wide DIN rail mount circuit breakers. May be arranged in many configurationsofloadsand batteries. Fuse options also available. (options)LVD Options: Single battery LVD. Up to 2x LVDs with independent controlmaybefittedonbattery or load side. (option)LVD Current Rating: 1200AMonitoring: SM31 (standard) SM32 TCP/IP enabled for web based viewing &configuration.(option)Supervisory Module Mounting: Door mounted for improved system terminal access.Battery Condition Monitoring: Optional full battery monobloc monitoring. (bloc voltage & string current) Environmental RequirementsTemperature: -10°C to +70°C (max. power de-rated above 50°C)Humidity: 5-95% RH (non-condensing)Altitude: <2500m, De-rate maximum ambient temperature by 4°C per 1000m above sea level.

MechanicalDimensions W, D, H: 600mm (23.6”), 19” standard mounting rails, 600mm (23.6”), 2000mm (78 ¾”) 40U of rack space.Weight: 180kg (approx)Shipping Size L, W, H 2100mm, 720mm, 830mmShipping weight: 195kg (approx)

CompliancesSafety: EN60950

Part Numbers: Actual part numbers will vary with congifuration. Contact us for further details on a solution that suits your requirements.

48V nominal output voltage.

54.0kW scalable output power.

2.0M LARGE DATA CENTER SOLUTIONS

Page 22: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 2�

48V nominal output voltage.

4.0kW maximum output power.

WALL MOUNT SYSTEM 4.0kW 48V DC / 2.1kW 24V DC

AC Input: Single phase with surge protection and input 32A MCB

(refertorectifierbrochureforfulldetails)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full load)

Termination: Single phase. Direct MCB termination for L. 10mm² N, E tunnel

terminals.

DC Output Nominal Voltages: -48V version. +24V version.

Max Rated System Output Power: 4000W @ -48V DC, 83A max. 2140W @ +24V DC, 80A max.

Polarity: Positive earth. Negative Earth.

1xRM30483000Wrectifieror 1xRM23242140Wrectifieror

2xRM20482000Wrectifiers. 2xRM1848/24900Wrectifiers.

DC Distribution:

Load: Max 8x 18mm MCB load circuit breakers.

Battery: Max 2x 18mm MCB load circuit breakers.

Breaker Fail Detection: Electronic fuse fail. (Auxiliaries optional)

DC Terminals: Live: Direct MCB connections.

Load: Common: 16mm tunnel terminals.

Battery: Common: 35mm tunnel terminals.

LowVoltageDisconnect: 80AbatteryLVDfittedasstandardon-48Vand24Vsystems.

Weight: Approx. 10.5Kg

Dimensions (L, H,W): 620mm x 375mm x 80mm

Shipping Dimensions (L, H,W): 730mm x 470mm x 200mm

Monitoring and Control: Various monitoring options via the Enatel SM30 series of control

& supervisory modules. Standard features include full temperature

compensation, automated and manual battery testing/equalisation

and three voltage-free relay alarm outputs. Options include extension

remote I/O PCBs that give an extra 6x digital inputs, 6x analogue

inputs and 8x voltage-free relay outputs. For further details,

refer to the SM30 series of brochures.

Part Numbers: Actual part numbers will vary with congifuration.

PSW-4204810-000: 48V,2x2000Wrectifiers,SM31supervisorymodule.

PSW-4204820-000: 48V,2x2000Wrectifiers,SM32supervisorymodule.

(Remote communication via SNMP)

PSW-3104810-000: 48V,1x3000Wrectifier,SM31supervisorymodule.

PSW-3104820-000: 48V,1x3000Wrectifier,SM32supervisorymodule.

(Remote communication via SNMP)

PSW-2102410-000: 24V,1x2140Wrectifier,SM31supervisorymodule.

PSW-2102420-000: 24V,1x2140Wrectifier,SM32supervisorymodule.

(Remote communications via SNMP)

PSW-2202410-000: 24V,2x900Wrectifiers,SM31supervisorymodule.

PSW-2202420-000: 24V,2x900Wrectifiers,SM32supervisorymodule.

(Remote communication via SNMP)

24V nominal output voltage.

2.1kW maximum output power.

Page 23: Enatel Limited - Product Catalogue 2010 v1.0

24 | ENATEL | 2010 PRODUCT CATALOGUE

If you are looking for modular, plug and play rectifiers with some of the highest

power densities in the market you have come to the right place.

These rectifiers are designed for integration into systems that require intelligent

features and remote control. With efficiencies in excess of 92% and power

factors of greater than 0.98 these rectifiers will save operating costs, and reduce

heat dissipation.

Suitable for powering a wide range of telecommunications and data networking

applications including wireless, access networks and central office switching

environments.

MODULAR RECTIFIERS

- Force cooled.

- Microprocessor controlled.

- Power factor corrected.

- Thermally protected.

- Input/output voltage

and current protected.

- Serial alarm and control interface.

Page 24: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 25

RM�048 �.0kW 48V DC MODULAR RECTIFIER

AC InputNominal: 230VVoltage Range: 90-300V (reduced power below 175V)Frequency Range: 45-65 Hz Power Factor: >0.99Efficiency: >92%(>45%outputpower)Input Fuses: HRC fuses in phase and neutral.Maximum Input Current: 19AProtection: Input Voltage: Auto shutdown, auto restart when correct voltage restored. Input Inrush: <2x maximum input current.

DC OutputOutput Ratings: Constant power output from 50V to 58V Nominal Voltage: 48V Rated Voltage: 58V Voltage Range: 43-60V Maximum Current: 60ARegulation: Line: ±0.1% Load: ±0.5% (no load to full load)Hold-up Time: >15ms for 20% output voltage drop.Start-up Time: Start up delay 1 second. (varies with AC supply voltage) Walk-in delay 6 seconds at full output. (varies with DC output voltage)Protection: Current Limit: Adjustable to 50-100% of maximum rated current. Over Temperature: Automatic current turndown, backup shutdown protection. Polarity Reversal: Output fuse with crowbar diode. Over voltage: Adjustable limit.Noise: (under nominal conditions) Ripple <100Hz: <1mV rms unweighted Voice band 100Hz-5KHz: <1mV rms psophometric Wide band 5kHz-1MHz: <5mV rms unweighted Peak to Peak 0-20MHz: <50mV peak to peakIsolation: Input to Output: 4000V DC Input to Chassis: 3500V DC (VDR to chassis removed) Output to Chassis: 2100V DC

Environmental RequirementsAmbient Temperature: Nominal: 25+/-5ºC Range: -10ºC to +70ºC (maximum output power is derated above +50ºC)Storage Temperature: -20ºC to +70ºCHumidity: 5-95% RH (non-condensing)Altitude: <2500m, De-rate maximum ambient temperature by 4ºC per 1000m above sea level.

MechanicalDimensions, W, H, D: 41mm, 220mm, 305mm overall.Weight: 2.7kg Shipping Dimensions W, H, D: 52mm, 230mm, 340mmShipping Weight: 2.85kgCooling: Forced cooled, using dual temperature controlled high reliability fans.

CompliancesSafety: EN60950Electrostatic Discharge: CISPR24Radiated Radio Frequency: CISPR22AC Harmonics: EN61000-3-2 AC Flicker and Fluctuation: EN61000-3-3 Other: CE & RoHS compliant.

48V nominal output voltage.

3.0kW nominal output power.

60.0A maximum output current.

Page 25: Enatel Limited - Product Catalogue 2010 v1.0

26 | ENATEL | 2010 PRODUCT CATALOGUE

AC InputNominal: 230VVoltage Range: 90-300V (reduced power below 175V)Frequency Range: 45-65 HzPower Factor: >0.99Efficiency: >92%(>45%outputpower)Input Fuses: HRC fuses in phase and neutral.Maximum Input Current: 19AProtection: Input Voltage: Auto shutdown, auto restart when correct voltage restored. Input Inrush: <2x maximum input current.

DC Output - Software Switchable 48V 24VOutput Ratings: Constant power output from 50V to 60V Current limited to 60A Nominal Voltage: 48V 24V Rated Voltage: 58V 29V Voltage Range: 43-60V 21-30V Maximum Current: 60A 60ARegulation: Line: ±0.1% Load: ±0.5% (no load to full load)Hold-up Time: >15ms for 20% output voltage drop.Start-up Time: Start up delay 1 second. (varies with AC supply voltage) Walk-in delay 6 seconds at full output. (varies with DC output voltage)Protection: Current Limit: Adjustable to 50-100% of maximum rated current. Over Temperature: Automatic current turndown, backup shutdown protection. Polarity Reversal: Output fuse with crowbar diode. Over voltage: Adjustable limit.Noise: (under nominal conditions) Ripple <100Hz: <1mV rms unweighted Voice band 100Hz-5KHz: <1mV rms psophometric Wide band 5kHz-1MHz: <5mV rms unweighted Peak to Peak 0-20MHz: <50mV peak to peakIsolation: Input to Output: 4000V DC Input to Chassis: 3500V DC (VDR to chassis removed) Output to Chassis: 2100V DC

Environmental RequirementsAmbient Temperature: Nominal: 25+/-5ºC Range: -10ºC to +70ºC (maximum output power is derated above +50ºC)Storage Temperature: -20ºC to +70ºCHumidity: 5-95% RH (non-condensing)Altitude: <2500m, De-rate maximum ambient temperature by 4ºC per 1000m above sea level.

MechanicalDimensions, W, H, D: 41mm, 220mm, 305mm overall.Weight: 2.7kg Shipping Dimensions W, H, D: 52mm, 230mm, 340mmShipping Weight: 2.85kgCooling: Forced cooled, using dual temperature controlled high reliability fans.

CompliancesSafety: EN60950Electrostatic Discharge: CISPR24Radiated Radio Frequency: CISPR22AC Harmonics: EN61000-3-2 AC Flicker and Fluctuation: EN61000-3-3Other: CE & RoHS compliant.

RM�048/24 �.0kW 48V DC / 1.7kW 24V DC MODULAR RECTIFIER

48V nominal output voltage.

3.0kW nominal output power.

24V nominal output voltage.

1.7kW nominal output power.

60.0A maximum output current.

Page 26: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 27

AC InputNominal: 230VVoltage Range: 90-300V (reduced power below 175V)Frequency Range: 45-65 HzPower Factor: >0.99Efficiency: >92%(>45%outputpower)Input Fuses: HRC fuses in phase and neutral.Maximum Input Current: 19AProtection: Input Voltage: Auto shutdown, auto restart when correct voltage restored. Input Inrush: <2x maximum input current.

DC Output - Software Switchable 60V 48VOutput Ratings: Constant power output from 60V to 74V Current limited to 50A Nominal Voltage: 60V 48V Rated Voltage: 68V 58V Voltage Range: 52-74V 43-60V Maximum Current: 50A 50A

Regulation: Line: ±0.1% Load: ±0.5% (no load to full load)Hold-up Time: >15ms for 20% output voltage dropStart-up Time: Start up delay 1 second. (varies with AC supply voltage) Walk-in delay 6 seconds at full output. (varies with DC output voltage)Protection: Current Limit: Adjustable to 50-100% of maximum rated current. Over Temperature: Automatic current turndown, backup shutdown protection. Polarity Reversal: Output fuse with crowbar diode. Over voltage: Adjustable limit.Noise: (under nominal conditions) Ripple <100Hz: <1mV rms unweighted Voice band 100Hz-5KHz: <1mV rms psophometric Wide band 5kHz-1MHz: <5mV rms unweighted Peak to Peak 0-20MHz: <50mV peak to peakIsolation: Input to Output: 4000V DC Input to Chassis: 3500V DC (VDR to chassis removed) Output to Chassis: 2100V DC

Environmental RequirementsAmbient Temperature: Nominal: 25+/-5ºC Range: -20ºC to +70ºC (maximum output power is derated above +50ºC)Storage Temperature: -20ºC to +70ºCHumidity: 5-95% RH (non-condensing)Altitude: <2500m, De-rate maximum ambient temperature by 4ºC per 1000m above sea level. MechanicalDimensions, W, H, D: 41mm, 220mm, 305mm overall.Weight: 2.8kg Shipping Dimensions W, H, D: 52mm, 230mm, 340mmShipping Weight: 2.95kgCooling: Forced cooled, using dual temperature controlled high reliability fans.

CompliancesSafety: EN60950Electrostatic Discharge: CISPR24Radiated Radio Frequency: CISPR22AC Harmonics: EN61000-3-2 AC Flicker and Fluctuation: EN61000-3-3 Other: CE & RoHS compliant.

RM�060/48 �.0kW 60/48V DC MODULAR RECTIFIER

60/48V nominal output voltage.

3.0kW nominal output power.

50.0A maximum output current.

Page 27: Enatel Limited - Product Catalogue 2010 v1.0

28 | ENATEL | 2010 PRODUCT CATALOGUE

RM2�24 2.�kW 24V DC MODULAR RECTIFIER

AC InputNominal: 230VVoltage Range: 90-300V (reduced power below 150V)Frequency Range: 45-65 HzPower Factor: >0.99Efficiency: >91%(>45%outputpower)Input Fuses: HRC fuses in phase and neutral.Maximum Input Current: 19AProtection: Input Voltage: Auto shutdown, auto restart when correct voltage restored. Input Inrush: <2x maximum input current.

DC Output Output Ratings: Current limited to 80A Nominal Voltage: 24V Rated Voltage: 29V Voltage Range: 21-30V Maximum Current: 80ARegulation: Line: ±0.1% Load: ±0.5% (no load to full load)Hold-up Time: >15ms for 20% output voltage drop.Start-up Time: Start up delay 1 second. (varies with AC supply voltage) Walk-in delay 7 seconds at full output. (varies with DC output voltage)Protection: Current Limit: Adjustable to 50-100% of maximum rated current. Over Temperature: Automatic current turndown, backup shutdown protection. Polarity Reversal: Output fuse with crowbar diode. Over voltage: Adjustable limit.Noise: (under nominal conditions) Ripple <100Hz: <1mV rms unweighted Voice band 100Hz-5KHz: <1mV rms psophometric Wide band 5kHz-1MHz: <5mV rms unweighted Peak to Peak 0-20MHz: <50mV peak to peakIsolation: Input to Output: 4000V DC Input to Chassis: 3500V DC (VDR to chassis removed) Output to Chassis: 2100V DC

Environmental RequirementsAmbient Temperature: Nominal: 25+/-5ºC Range: -10ºC to +70ºC (maximum output power is derated above +50ºC)Storage Temperature: -20ºC to +70ºCHumidity: 5-95% RH (non-condensing)Altitude: <2500m, De-rate maximum ambient temperature by 4ºC per 1000m above sea level.

MechanicalDimensions, W, H, D: 41mm, 220mm, 305mm overall.Weight: 2.7kg Shipping Dimensions W, H, D: 52mm, 230mm, 340mmShipping Weight: 2.75kgCooling: Forced cooled, using dual temperature controlled high reliability fans.

CompliancesSafety: EN60950Electrostatic Discharge: CISPR24Radiated Radio Frequency: CISPR22AC Harmonics: EN61000-3-2 AC Flicker and Fluctuation: EN61000-3-3Other: CE & RoHS compliant.

24V nominal output voltage.

2.3kW nominal output power.

80.0A maximum output current.

Page 28: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 29

RM2048XP 2.0KW 48V DC MODULAR RECTIFIER

AC InputNominal: 230VVoltage Range: 90-300V (reduced power below 175V)Frequency Range: 45-65 Hz Power Factor: >0.99 Efficiency: >92%(>50%outputpower)Total Harmonic Distortion (THD): <5% (>30% output power)Input Fuses: HRC fuses in phase and neutral.Maximum Input Current: 12A Protection: Input Voltage: Auto shutdown, auto restart when correct voltage restored. Input Inrush: <12A rms

DC OutputOutput Ratings: Constant power output from 48V to 58V Nominal Voltage: 48V Rated Voltage: 58V Voltage Range: 43-60V Maximum Current: 41.7ARegulation: Line: ±0.1% Load: ±0.5% (no load to full load)Hold-up Time: >15ms for 20% output voltage drop.Start-up Time: Start up delay 1 second. (varies with AC supply voltage) Walk-in delay 6 seconds at full output. (varies with DC output voltage) Protection: Current Limit: Adjustable to 50-100% of maximum rated current. Over Temperature: Automatic current turndown, backup shutdown protection. Polarity Reversal: Output fuse with crowbar diode. Over voltage: Adjustable limit.Noise: (under nominal conditions) Ripple <100Hz: <1mV rms unweighted Voice band 100Hz-5KHz: <1mV rms psophometric Wide band 5kHz-1MHz: <5mV rms unweighted Peak to Peak 0-20MHz: <100mV peak to peakIsolation: Input to Output: 4000V DC Input to Chassis: 3500V DC (VDR to chassis removed) Output to Chassis: 2100V DC

Environmental RequirementsAmbient Temperature: Nominal: 25+/-5ºC Range: -10ºC to +70ºC (maximum output power is derated above +50ºC)Storage Temperature: -20ºC to +70ºCHumidity: 5-95% RH (non-condensing)Altitude: <2500m, De-rate maximum ambient temperature by 4ºC per 1000m above sea level.

MechanicalDimensions, W, H, D: 111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)Weight: 1.5kg Shipping Dimensions W, H, D: 120mm, 52mm, 325mmShipping Weight: 1.6kgCooling: Forced cooled.

CompliancesSafety: EN60950Electrostatic Discharge: CISPR24Radiated Radio Frequency: CISPR22AC Harmonics: EN61000-3-2 AC Flicker and Fluctuation: EN61000-3-3 Other: CE & RoHS compliant.

48V nominal output voltage.

2.0kW nominal output power.

41.7A maximum output current.

Page 29: Enatel Limited - Product Catalogue 2010 v1.0

�0 | ENATEL | 2010 PRODUCT CATALOGUE

RM2048/24 2.0kW 48V DC / 1.0kW 24V DC MODULAR RECTIFIER

AC InputNominal: 230VVoltage Range: 90-300V (reduced power below 175V)Frequency Range: 45-65 HzPower Factor: >0.99Efficiency: >91%(>50%outputpower) Input Fuses: HRC fuses in phase and neutral. Maximum Input Current: 13AProtection: Input Voltage: Auto shutdown, auto restart when correct voltage restored. Input Inrush: <2x maximum input current.

DC Output - Software Switchable 48V 24VOutput Ratings: Constant power output from 54V to 60V Current limited to 41.7A Nominal Voltage: 48V 24V Rated Voltage: 58V 29V Voltage Range: 43-60V 21-30V Maximum Current: 41.7A 41.7ARegulation: Line: ±0.1% Load: ±0.5% (no load to full load)Hold-up Time: >15ms for 20% output voltage drop.Start-up Time: Start up delay 1 second. (varies with AC supply voltage) Walk-in delay 6 seconds at full output. (varies with DC output voltage)Protection: Current Limit: Adjustable to 50-100% of maximum rated current. Over Temperature: Automatic current turndown, backup shutdown protection. Polarity Reversal: Output fuse with crowbar diode. Over voltage: Adjustable limit.Noise: (under nominal conditions) Ripple <100Hz: <1mV rms unweighted Voice band 100Hz-5KHz: <1mV rms psophometric Wide band 5kHz-1MHz: <5mV rms unweighted Peak to Peak 0-20MHz: <50mV peak to peakIsolation: Input to Output: 4000V DC Input to Chassis: 3500V DC (VDR to chassis removed) Output to Chassis: 2100V DC

Environmental RequirementsAmbient Temperature: Nominal: 25+/-5ºC Range: -10ºC to +70ºC (maximum output power is derated above +50ºC)Storage Temperature: -20ºC to +70ºCHumidity: 5-95% RH (non-condensing)Altitude: <2500m, De-rate maximum ambient temperature by 4ºC per 1000m above sea level.

MechanicalDimensions, W, H, D: 111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)Weight: 1.5kg Shipping Dimensions W, H, D: 120mm, 52mm, 325mmShipping Weight: 1.6kgCooling: Forced cooled.

CompliancesSafety: EN60950Electrostatic Discharge: CISPR24Radiated Radio Frequency: CISPR22AC Harmonics: EN61000-3-2 AC Flicker and Fluctuation: EN61000-3-3Other: CE & RoHS compliant.

48V nominal output voltage.

2.0kW nominal output power.

1.0kW nominal output power.

24V nominal output voltage.

41.7A maximum output current.

Page 30: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | �1

RM1860/48 1.8kW 60/48V DC MODULAR RECTIFIER

AC InputNominal: 230V Voltage Range: 90-300V (reduced power below 175V)Frequency Range: 45-65 HzPower Factor: >0.99Efficiency: >91%(>50%outputpower)Input Fuses: HRC fuses in phase and neutral.Maximum Input Current: 11AProtection: Input Voltage: Auto shutdown, auto restart when correct voltage restored. Input Inrush: <2x maximum input current.

DC Output - Software Switchable 60V 48VOutput Ratings: Constant power output from 60V to 74V Current limited to 30ANominal Voltage: 60V 48VRated Voltage: 68V 54VVoltage Range: 52-74V 43-60VMaximum Current: 30A 30ARegulation: Line: ±0.1% Load: ±0.5% (no load to full load)Hold-up Time: >15ms for 20% output voltage dropStart-up Time: Start up delay 1 second. (varies with AC supply voltage) Walk-in delay 6 seconds at full output. (varies with DC output voltage) Protection: Current Limit: Adjustable to 50-100% of maximum rated current. Over Temperature: Automatic current turndown, backup shutdown protection. Polarity Reversal: Output fuse with crowbar diode. Over voltage: Adjustable limit.Noise: (under nominal conditions) Ripple <100Hz: <1mV rms unweighted Voice band 100Hz-5KHz: <1mV rms psophometric Wide band 5kHz-1MHz: <5mV rms unweighted Peak to Peak 0-20MHz: <50mV peak to peakIsolation: Input to Output: 4000V DC Input to Chassis: 3500V DC (VDR to chassis removed) Output to Chassis: 2100V DC

Environmental RequirementsAmbient Temperature: Nominal: 25+/-5ºC Range: -10ºC to +70ºC (maximum output power is derated above +50ºC)Storage Temperature: -20ºC to +70ºCHumidity: 5-95% RH (non-condensing)Altitude: <2500m, De-rate maximum ambient temperature by 4ºC per 1000m above sea level.

MechanicalDimensions, W, H, D: 111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)Weight: 1.4kg Shipping Dimensions W, H, D: 120mm, 52mm, 325mmShipping Weight: 1.5kgCooling: Forced cooled.

CompliancesSafety: EN60950Electrostatic Discharge: CISPR24Radiated Radio Frequency: CISPR22AC Harmonics: EN61000-3-2 AC Flicker and Fluctuation: EN61000-3-3 Other: CE & RoHS compliant.

60/48V nominal output voltage.

1.8kW nominal output power.

30.0A maximum output current.

Page 31: Enatel Limited - Product Catalogue 2010 v1.0

�2 | ENATEL | 2010 PRODUCT CATALOGUE

RM1048 1.0kW 48V DC MODULAR RECTIFIER

AC InputNominal: 230VVoltage Range: 90-300V (reduced power below 175V)Frequency Range: 45-65 HzPower Factor: >0.99Efficiency: >90%(>50%outputpower)Input Fuses: HRC fuses in phase and neutral.Protection: Input Voltage: Auto shutdown, auto restart when correct voltage restored. Input Inrush: <2x maximum input current. Maximum Input Current: 7A

DC OutputOutput Ratings: Constant power output from 48V to 58V Nominal Voltage: 48V Rated Voltage: 58V Voltage Range: 43-60V Maximum Current: 21ARegulation: Line: ±0.1% Load: ±0.5% (no load to full load)Hold-up Time: >15ms for 20% output voltage drop.Start-up Time: Start up delay 1 second. (varies with AC supply voltage) Walk-in delay 6 seconds at full output. (varies with DC output voltage) Protection: Current Limit: Adjustable to 50-100% of maximum rated current. Over Temperature: Automatic current turndown, backup shutdown protection. Polarity Reversal: Output fuse with crowbar diode. Over voltage: Adjustable limit.Noise: (under nominal conditions) Ripple <100Hz: <1mV rms unweighted Voice band 100Hz-5KHz: <1mV rms psophometric Wide band 5kHz-1MHz: <5mV rms unweighted Peak to Peak 0-20MHz: <50mV peak to peakIsolation: Input to Output: 4000V DC Input to Chassis: 3500V DC (VDR to chassis removed) Output to Chassis: 2100V DC

Environmental RequirementsAmbient Temperature: Nominal: 25+/-5ºC Range: -10ºC to +75ºC (maximum output power is derated above +50ºC)Storage Temperature: -20ºC to +75ºCHumidity: 5-95% RH (non-condensing)Altitude: <2500m, De-rate maximum ambient temperature by 4ºC per 1000m above sea level.

MechanicalDimensions, W, H, D: 111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)Weight: 1.4kg Shipping Dimensions W, H, D: 120mm, 52mm, 325mmShipping Weight: 1.5kgCooling: Forced cooled

CompliancesSafety: EN60950Electrostatic Discharge: CISPR24Radiated Radio Frequency: CISPR22AC Harmonics: EN61000-3-2 AC Flicker and Fluctuation: EN61000-3-3 Other: CE & RoHS compliant.

48V nominal output voltage.

1.0kW nominal output power.

21.0A maximum output current.

Page 32: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | ��

RM848 800W 48V DC MODULAR RECTIFIER

AC InputNominal: 230VVoltage Range: 90-300V (reduced power below 175V)Frequency Range: 45-65 Hz Power Factor: >0.99Efficiency: >92%(>50%outputpower)Input Fuses: HRC fuses in phase and neutral. Maximum Input Current: 5.5AProtection: Input Voltage: Auto shutdown, auto restart when correct voltage restored. Input Inrush: <2x maximum input current.

DC OutputOutput Ratings: Constant power output from 54V to 58V Nominal Voltage: 48V Rated Voltage: 58V Voltage Range: 43-60V Maximum Current: 16.6ARegulation: Line: ±0.1% Load: ±0.5% (no load to full load)Hold-up Time: >15ms for 20% output voltage drop.Start-up Time: Start up delay 1 second. (varies with AC supply voltage) Walk-in delay 6 seconds at full output. (varies with DC output voltage) Protection: Current Limit: Adjustable to 50-100% of maximum rated current. Over Temperature: Automatic current turndown, backup shutdown protection. Polarity Reversal: Output fuse with crowbar diode. Over voltage: Adjustable limit.Noise: (under nominal conditions) Ripple <100Hz: <1mV rms unweighted Voice band 100Hz-5KHz: <2mV rms psophometric Wide band 5kHz-1MHz: <5mV rms unweighted Peak to Peak 0-20MHz: <50mV peak to peakIsolation: Input to Output: 4000V DC Input to Chassis: 3500V DC (VDR to chassis removed) Output to Chassis: 2100V DC

Environmental RequirementsAmbient Temperature: Nominal: 25+/-5ºC Range: -20ºC to +70ºC (maximum output power is derated above +50ºC)Storage Temperature: -20ºC to +70ºCHumidity: 0-98% RH (non-condensing)Altitude: <3000m, De-rate maximum ambient temperature by 4ºC per 1000m above sea level.

MechanicalDimensions, W, H, D: 55mm , 44mm (1U), 235mm overall (rack depth 260mm)Weight: 800g Shipping Dimensions W, H, D: 100mm, 80mm, 300mmShipping Weight: 1.0kgCooling: Forced cooled.

CompliancesSafety: EN60950Electrostatic Discharge: CISPR24Radiated Radio Frequency: CISPR22AC Harmonics: EN61000-3-2 AC Flicker and Fluctuation: EN61000-3-3 Other: CE & RoHS compliant.

48V nominal output voltage.

800W nominal output power.

16.6A maximum output current.

Page 33: Enatel Limited - Product Catalogue 2010 v1.0

�4 | ENATEL | 2010 PRODUCT CATALOGUE

FLAT MOUNT RECTIFIERS

Flat mount rectifiers have been developed to allow provision of simple, and low

cost solutions where only a limited amount of rack space is available. With all

input and output connections available on the front panel of the rectifier units

they can be easily integrated in simple DC systems solutions.

With power ratings of �00W up to 1.4kW and output voltages of 12, 24 and

48V DC these rectifiers offer temperature compensation, and auto float/boost

switching as standard.

They have options available for internal low voltage disconnect (LVD) and an

alarm card, with relay outputs. These rectifiers can provide the powering solution

for most small and medium telecommunications, and data networking power

applications.

Efficient and reliable, these rack mounting rectifiers allow for easy paralleling of

modules to provide redundancy or higher power outputs. Internal options include

low voltage disconnect (LVD) and an alarm card with relay outputs.

The unique design allows for mounting two rectifiers in a 1U x 19” rack space.

Custom configurations can be specified and additional features can be added.

Easy to install and compact, these robust, reliable rectifiers are forced

cooled by a speed controlled and monitored fan.

- Forced cooled.

- Thermally protected.

- Power factor corrected.

- Input/output voltage

and current protected.

- Temperature compensation.

- Automatic float/boost charge cycle.

- Alarm and control interface

including active load sharing.

- Optional built-in low

voltage disconnect.

- Optional internal alarm

card with relay outputs.

Page 34: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | �5

RF SERIES FLAT MOUNT RECTIFIERS

AC Input RF1448 RF1124 RF748U RF624U RF512U RF348UNominal: 220/240V, 50/60Hz 220/240V, 50/60Hz 110-220V, 50/60Hz 110-220V, 50/60Hz 110-220V, 50/60Hz 110-220V, 50/60HzVoltage Range: 180-275V AC 180-275V AC 100-275V AC 100-275V AC 100-275V AC 100-275V AC (full power output), (full power output), (full power output), (full power output), (full power output), (full power output), 150-180V AC 150-180V AC 85-100V AC 85-100V AC 85-100V AC 85-100V AC (reduced power output) (reduced power output) (reduced power output) (reduced power output) (reduced power output) (reduced power output) Frequency Range: 45-66Hz Power Factor: >0.93 (full load) RF1448 RF1124 RF748U RF624U RF512U RF348U Efficiency: 92% 90% 89% 87% 85% 85%Maximum Input Current: 8.5A 8.5A 8.5A 8.5A 8.5A 8.5AInput Fuses: HRC fuses in phase & neutral.Protection: Input Voltage: Automatic shutdown, restarts automatically when correct voltage restored. Input Rush: <2x maximum input current.

DC Output RF1448 RF1124 RF748U RF624U RF512U RF348UNominal Voltage: 48V 24V 48V 24V 12V 48VRated Voltage: 58V 29V 58V 29V 14.5V 58VVoltage Range: 45-60V 22-30V 45-60V 22-30V 11.5-15V 45-60V Maximum Current: 25A 40A 12A 22A 40A 6A Regulation: Line: ±0.1% Load: ±0.5% (no load to full load)Hold-up Time: >15ms for 20% output voltage drop.Start-up Time: Walk-in delay 2 seconds. (depends on AC input voltage)Protection: Current Limit: Adjustable to 50-100% of maximum rated current. Over Temp: Automatic current turndown, backup shutdown protection. Polarity Reversal: Output fuse with crowbar diode. Over Voltage: Adjustable limit.Noise: (under nominal conditions) RF1448 RF1124 RF748U RF624U RF512U RF348U Ripple <100Hz: <10mV rms unweighted. <5mV rms unweighted. <10mV rms unweighted. <5mV rms unweighted. <5mV rms unweighted. <5mV rms unweighted. Voice Band 100Hz to 5KHz: <2mV rms psophometric. <1mV rms psophometric. <2mV rms psophometric. <1mV rms psophometric. <0.5mV rms psophometric. <0.5mV rms psophometric. Wide Band 5kHz to 1 MHz: <10mV rms unweighted. <5mV rms unweighted. <10mV rms unweighted. <5mV rms unweighted. <2.5mV rms unweighted. <2.5mV rms unweighted. Peak to Peak 0 to 20MHz: <50mV p-p unweighted. <50mV p-p unweighted. <50mV p-p unweighted. <50mV p-p unweighted. <50mV p-p unweighted. <50mV p-p unweighted.Isolation: Input to Output: 3000V AC Input to Chassis: 2500V AC (VDR to chassis removed) Output to Chassis: 1500V AC

Environmental RequirementsNominal Ambient Temperature: 25+/-5°CRange: -10 to +50°C Humidity: 5-95% RH (non-condensing.)Altitude: <2500mde-ratemaximumambienttemperatureby+4˚per1000mabovesealevel.

MechanicalDimensions, W, H, D: 227mm, 44mm (1U), 270mm, (293mm over handle)Weight: 1.5kgShipping Dimensions, W, H, D: 377mm, 235mm, 122mmShipping Weight: 2.4kgCooling: Forced cooled.Connections: Mains: IEC 320 universal connection. Output to Load: 4 way lumberg macromodule. Temperature Sensor: 2 way lumberg macromodule. Monitor Connection: RJ45 Internal Alarm Card: Mini combicon.

Standard FeaturesTemperature Compensation: Output voltage slope adjustable 0.1 to 0.2%/°C (standard)AutoFloat/Boost: Rectifierentersboostmodeatpowerup.Whenbatterycurrentreducestofloatthresholdlimit(adjustablefrom0.1Ato40%MRC),unitrevertstofloatvoltagesetting. Wheninboostbutoutofcurrentlimit,rectifierwillautomaticallyswitchbacktofloatafterapproximatelyfourhours. Ifbatterycurrentexceedsthefloatthresholdlimitwhentherectifierisinfloatmodeitwillautomaticallyswitchtoboostmode.Alarm and Indicator Controls: Positive V out, Load share signal (in/out), External shutdown, Open collector ‘off normal’ alarm, (OSVD, over temp., current limit, fan fail), LVD synchronisation signal (in/out), Temperaturecompensationinputsignal,Opencollectorrectifierfail(via4k7resistor),Opencollectormainsfail,NegativeVout.

OptionsLow Voltage Disconnect: RF1448 RF1124 RF748U RF624U RF512U RF348U Voltage Adjustment Range: 38-48V 19-24V 38-48V 19-24V 9.5-12V 38-48V Maximum Load Current: 25A 40A 12A 22A 40A 6AInternalAlarmCard: 4xN.OorN.C(selectable)relaycontactswithsinglecommonforrectifierfail,offnormal,floatlow,floathigh.1xVFchangeoverrelaycontactformainsfail. Relaycontactsratedat100VDC1A.Connectionsvia“minicombicon”connectoraccepts1.5mmdiawire.

MaintenanceLED Indicators: Green - Mains on. (primary converter operating) Green - Temperature probe connected and within normal limits. Red-Rectifier‘failed’. Green-Rectifierin‘float’mode. Yellow-Rectifierin‘boost’mode. Yellow-Rectifierin‘current’limit. Red-Rectifier‘offnormal’.(overtemp.,OVSD,lowoutputvolts)Internal Adjustments: Float voltage. Boost voltage. Over voltage shut down. Current limit. Temperature compensation slope. Autoboosttofloatthresholdlimit. Loaddisconnectvoltage.(iffitted) Loaddisconnecthysteresisvoltage.(iffitted)

CompliancesSafety: EN60950Electrostatic Discharge: CISPR24Radiated Radio Frequency: CISPR22AC Harmonics: EN61000-3-2AC Flicker and Fluctuation: EN61000-3-3

Ordering InformationRFxxxx-10: Standardwithtemperaturecompensation,autofloatboost,alarmandcontrolI/F.RFxxxx-11: Standardwithtemperaturecompensation,autofloatboost,alarmandcontrolI/F,lowvoltsdisconnect.RFxxxx-20: Standardwithtemperaturecompensation,autofloatboost,alarmandcontrolI/F,alarmcard.RFxxxx-21: Standardwithtemperaturecompensation,autofloatboost,alarmandcontrolI/F,lowvoltsdisconnect,alarmcard.

Page 35: Enatel Limited - Product Catalogue 2010 v1.0

�6 | ENATEL | 2010 PRODUCT CATALOGUE

WALL MOUNT RECTIFIERS

- Convection cooled.

- Thermally protected.

- Power factor corrected.

- Input/output voltage

and current protected.

- Automatic float/boost

charge cycle.

- Alarm and control interface

with active load sharing.

- Temperature compensation.

- Output current indicator.

- Optional built-in low

voltage disconnect.

- Optional internal alarm

card with relay outputs.

The Enatel RW series of wall mount rectifiers have been developed to provide

fully integrated power solutions for small telecommunications, and data

networking applications.

Easily paralleled to provide redundancy, or higher power outputs these rectifiers

are simple to install and can be bolted directly to a wall or flat panel space.

Providing outputs of 12, 24 and 48V from �00W up to 700W output these

rectifiers offer temperature compensation, and auto float/boost switching

as standard.

They have options available for internal low voltage disconnect (LVD) and an

alarm card, with relay outputs. These highly efficient rectifiers offer a range of

output voltages and power levels.

Easy to install and compact, these robust, reliable rectifiers are convection

cooled and are available with temperature compensation, and options for internal

low voltage disconnect (LVD) and alarm card with relay outputs.

They can be used as standalone power sources or can be operated in parallel to

provide redundancy or higher output ratings.

Choose from a range of internal options including load disconnect, current

indicators, alarm and control interface and auto float/boost. Custom

configurations can be specified and additional features can be added.

Page 36: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | �7

RW SERIES WALL MOUNT RECTIFIERS

AC InputNominal: 110/220V, 50/60HzVoltage Range: 100-275V AC (full power output), 85-100V AC (reduced power output) Frequency Range: 45-66Hz Power Factor: >0.99 (full load) RW748U RW624U RW512U RW348U RW324U RW312U Efficiency: 88% 87% 85% 88% 87% 85%Maximum Input Current: 8.5A 8.5A 8.5A 8.5A 4A 4AInput Fuses: HRC fuses in phase & neutral.Protection: Input Voltage: Automatic shutdown, restarts automatically when correct voltage restored. Input Rush: <2x maximum input current.

DC Output RW748U RW624U RW512U RW348U RW324U RW312UNominal Voltage: 48V 24V 12V 48V 24V 12VRated Voltage: 58V 29V 14.5V 58V 29V 14.5VVoltage Range: 45-60V 22-30V 11.5-15V 45-60V 22-30V 11.5-15V Maximum Current: 12A 700W 22A 600W 35A 6A 300W 10A 300W 20A 300WRegulation: Line: ±0.1% Load: ±0.5% (no load to full load)Hold-up Time: >15ms for 20% output voltage drop.Start-up Time: Walk-in delay 2 seconds (depends on AC input voltage)Protection: Current Limit: Adjustable to 50-100% of maximum rated current. Over Temp: Automatic current turndown, backup shutdown protection. Polarity Reversal: Output fuse with crowbar diode. Over Voltage: Adjustable limit.Noise: (under nominal conditions) RW748U RW624U RW512U RW348U RW324U RW312U Ripple <100Hz: <10mV rms unweighted. <5mV rms unweighted. <5mV rms unweighted. <10mV rms unweighted. <5mV rms unweighted. <5mV rms unweighted. Voice Band 100Hz to 5KHz: <2mV rms psophometric. <1mV rms psophometric. <0.5mV rms psophometric. <2mV rms psophometric. <1mV rms psophometric. <0.5mV rms psophometric. Wide Band 5kHz to 1 MHz: <10mV rms unweighted. <5mV rms unweighted. <2.5mV rms unweighted. <10mV rms unweighted. <5mV rms unweighted. <2.5mV rms unweighted. Peak to Peak 0 to 20MHz: <50mV p-p unweighted. <50mV p-p unweighted. <50mV p-p unweighted. <50mV p-p unweighted. <50mV p-p unweighted. <50mV p-p unweighted.Isolation: Input to Output: 3000V AC. Input to Chassis: 2500V AC (VDR to chassis removed) Output to Chassis: 1500V AC Environmental RequirementsNominal Ambient Temperature: 25+/-5°CRange: -10 to +50°CHumidity: 5-95% RH (non-condensing)Altitude: <2500mde-ratemaximumambienttemperatureby+4˚per1000mabovesealevel.

MechanicalDimensions, W, H, D: 311mm, 163mm, 62mmWeight: 1.5kgShipping Dimensions, W, H, D: 377mm, 235mm, 122mmShipping Weight: 2.4kgCooling: Convection cooled.Connections: Mains: IEC 320 universal connection. Output to Load: 4 way lumberg macromodule. Output to Batteries: 4 way lumberg macromodule. Temperature Sensor: 2 way lumberg macromodule. Monitor Connection: RJ45. Internal Alarm Card: Mini combicon.

Standard FeaturesOutputCurrentIndicator: TensegmentredLED“dot”display(standard)Temperature Compensation: Output voltage slope adjustable 0.1 to 0.2%/°C (standard)AutoFloat/Boost: Rectifierentersboostmodeatpowerup.Whenbatterycurrentreducestofloatthresholdlimit(adjustablefrom0.1Ato40%MRC),unitrevertstofloatvoltagesetting. Wheninboostbutoutofcurrentlimit,rectifierwillautomaticallyswitchbacktofloatafterapproximatelyfourhours. Ifbatterycurrentexceedsthefloatthresholdlimitwhentherectifierisinfloatmodeitwillautomaticallyswitchtoboostmode.Alarm and Indicator Controls: Positive V out, Load share signal (in/out), External shutdown, Open collector ‘off normal’ alarm (OSVD, over temp. limit), LVD synchronisation signal (in/out) Temperaturecompensationinputsignal,Opencollectorrectifierfail(via4k7resistor),Opencollectormainsfail,NegativeVout.

OptionsLow Voltage Disconnect: RW748U RW624U RW512U RW348U RW324U RW312U Voltage Adjustment Range: 38-48V 19-24V 9.5-12V 38-48V 19-24V 9.5-12V Maximum Load Current: 12A 22A 35A 6A 10A 20AInternalAlarmCard: 4xN.OorN.C(selectable)relaycontactswithsinglecommonforrectifierfail,offnormal,floatlow,floathigh.1xVFchangeoverrelaycontactformainsfail. Relaycontactsratedat100VDC1A.Connectionsvia“minicombicon”connectoraccepts1.5mmdiawire.

MaintenanceLED Indicators: Green - Mains on. (primary converter operating) Green - Temperature probe connected and within normal limits. Red-Rectifier‘failed’. Green-Rectifierin‘float’mode. Yellow-Rectifierin‘boost’mode. Yellow-Rectifierin‘current’limit. Red-Rectifier‘offnormal’.(overtemp.OVSD,lowoutputvolts)Internal Adjustments: Float voltage. Boost voltage. Over voltage shut down. Current limit. Temperature compensation slope. Autoboosttofloatthresholdlimit. Loaddisconnectvoltage.(iffitted) Loaddisconnecthysteresisvoltage.(iffitted)

CompliancesSafety: EN60950Electrostatic Discharge: CISPR24Radiated Radio Frequency: CISPR22AC Harmonics: EN61000-3-2AC Flicker and Fluctuation: EN61000-3-3

Ordering InformationRWxxxx-10: Standardwithtemperaturecompensation,autofloatboost,alarmandcontrolI/F.RWxxxx-11: Standardwithtemperaturecompensation,autofloatboost,alarmandcontrolI/F,lowvoltsdisconnect.RWxxxx-20: Standardwithtemperaturecompensation,autofloatboost,alarmandcontrolI/F,alarmcard.RWxxxx-21: Standardwithtemperaturecompensation,autofloatboost,alarmandcontrolI/F,lowvoltsdisconnect,alarmcard.

Page 37: Enatel Limited - Product Catalogue 2010 v1.0

�8 | ENATEL | 2010 PRODUCT CATALOGUE

DC-AC POWER SYSTEMS

Enatel’s ISM series inverter solutions offer a hot swappable modular inverter

system for supplying critical AC loads in telecom, and data networking

applications.

One of the unique features offered by the Enatel system solution is the ability to

integrate AC/DC rectifiers, DC/DC converters and also DC/AC inverters into a

system with a single controller, providing remote monitoring capabilities from a

single point.

The inverter modules are available in 1.5kVA with either 110/120 or 220/2�0V AC

output, and are scalable up to 15kVA. The inverter system solutions also include

12kVA static switch and maintenance bypass modules.

For further information on Enatel’s range of inverter systems, contact us today.

- Integrated monitoring presents

simplified systems management.

- Hot-swap/hot-plug modules

with n+1 redundancy.

- Small size means more room for

revenue generating equipment.

- Fully featured telecom

grade inverters.

- TCP/IP and SNMP network

monitoring optional.

- High reliability means

less cost of maintenance.

- Full remote monitoring reduces

maintenance costs.

- Easily customized and configured to

suit eachcustomers individual needs.

7U Inverter System

IM10230-48

IM10230-48

IM10230-48

IM10230-48

IM10230-48

IM10230-48

IM10230-48

IM10230-48

IM10230-48

Supervisory ModuleSM32

Page 38: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | �9

Efficient and reliable, these modular rack mount inverters allow for easy

paralleling of modules to provide redundancy or higher power outputs.

Designed for use in modern telecommunications networks these inverters

offer unrivalled power densities.

The unique design allows for mounting nine inverters in a 5U x 19” rack space

or two inverters in a 1U x 19” rack space.

“Plug and Play” installation allows quick and easy installation and system

expansion. These robust, reliable inverters are forced cooled by two speed

controlled and monitored high reliability fans.

- Pure sine wave.

- Hot swapable.

- High efficiency.

- Smart fan speed control.

- Wide operation temperature range.

- DSP chip designed.

- N+X redundancy system.

- Lower audible noise.

- High power density.

- Enatel RCP bus.

- 48V DC telecom system application.

- CE & RoHS compliant.

DC-AC INVERTERS

Page 39: Enatel Limited - Product Catalogue 2010 v1.0

40 | ENATEL | 2010 PRODUCT CATALOGUE

IM SERIES MODULAR INVERTERS

DC Input

Operating Voltage Range: 40.5-58V DC

AC Output

Nominal Output Voltage: 110/230V AC (refer to part number table below for model numbers)

Output Voltage Range: 110/115/120V AC or 208/220/230/240V AC

Output Voltage Tolerance: +/- 2%

Output Voltage Frequency: 50/60Hz selectable.

Output Frequency Tolerance: +/- 0.5%

Total Harmonic Distortion: <3% on linear loads.

<5% for non linear loads.

Turn On Delay: <3 seconds.

Crest Factor: 3:1 (nominal power)

Efficiency: 90%

Output Power (refer to part number table below for model numbers)

Nominal Value: 1000VA, 800W/

1500VA, 1200W

Overload (5 Seconds): 2000VA

Permanent Overload: 10%

Admissible Load Power Factor: 0 inductive to 0 capacitive (100% load)

Isolation:

Input/Output: 2500V AC

Output/Earth: 2500V AC

Input Earth: 1500V AC

Operating Temperature Range: -40ºC to +50ºC, derated to +70ºC

Acoustic Noise: <55dBa @ 1m

Display: 3x LEDs, fail, off normal, power on.

Serial Comms: Enatel SBI interface to SM3X supervisory module.

Mechanical

Dimensions, W, H, D: 215mm, 43.8mm, 270mm overall.

Weight: 2.5kg

Shipping Dimensions W, H, D: 52mm, 230mm, 340mm

Shipping Weight: 2.65kg

Cooling: Forced cooled.

Compliances

Immunity: CISPR24

Emissions: CISPR22 Class B

Safety: IEC60950

Other: CE & RoHS compliant.

Part Numbers

IM10230-48: 1U, 48V DC input, 230V AC output, 1.0kVA 800W

IM10110-48: 1U, 48V DC input, 120V AC output, 1.0kVA 800W

IM15230-48: 1U, 48V DC input, 230V AC output, 1.5kVA 1200W

IM15110-48: 1U, 48V DC input, 120V AC output, 1.5kVA 1200W

Page 40: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 41

SBM SERIES STATIC BYPASS MODULE

The Enatel SBM series static bypass module increases system reliability by

automatically switching between the inverter output and the utility supply.

The SBM12000 can be programmed so that the system operates in a standby

backup mode were the utility is the normal source of supply or alternatively the

system can be the normal source of supply with automatic switchover to the

utility in the event of system failure.

- Universal input range.

- Hot-swap replacement in shelf.

- Back feed protection.

- Redundant fan design.

- Redundant power supply design.

- Fast transfer time, typically

less than ¼ cycle.

- Wide operation temperature

range -20 to +70°C.

- Lower audible noise <55dBA.

- Emergency power off

function embedded.

- No-cross connect.

- Optional maintenance bypass

switch function with interlock.

- Operation priority setup of

transfer side by setting in

controller module.

Input

AC Voltage Range:

110/115/120V AC: From 89 to 138V AC.

208/220/240V AC: 176 to 276V AC.

Over Voltage Threshold:

Adjustable Using Controller:

220 to 240V AC for 208V AC systems.

233 to 252V AC for 220V AC systems.

244 to 264V AC for 230V AC systems.

254 to 276V AC for 240V AC systems.

117 to127V AC for 110V AC systems.

122 to 132V AC for 115V AC systems.

127 to 138V AC for 120V AC systems.

Under Voltage Threshold:

Adjustable Using Controller:

176 to 198V AC for 208V AC systems.

176 to 209V AC for 220V AC systems.

185 to 218V AC for 230V AC systems.

193 to 228V AC for 240V AC systems.

89 to 105V AC for 110V AC systems.

93 to 110V AC for 115V AC systems.

100 to 114V AC for 120V AC systems.

Redundant Power Supply Design: Startup power-on by priority source or alternative.

Output

Waveform: Sinusoidal.

Nominal Output Voltage: Same as mains AC or the output of inverter modules.

Permissible Frequency Area: Max. ±2.5% (Synchronize area of inverter).

±1.5Hz for 60Hz inverter.

±1.25Hz for 50Hz inverter.

Transfer Time: Typical ¼ cycle.

Rated Current: 50A (All voltage settings).

Operation Methods: Inverter priority or utility priority (Programmable).

Part Number:

SBM12000: 50A/12kVA static bypass module.

Page 41: Enatel Limited - Product Catalogue 2010 v1.0

42 | ENATEL | 2010 PRODUCT CATALOGUE

These converters offer plug and play operation, and can be easily paralleled to

provide higher power outputs.

These units offer the same high levels of conversion efficiency as other Enatel

power products, and will provide the same benefits to the customer of reduced

operating costs and lower levels of heat dissipation.

The converters include a relay contact to indicate converter failure, and have a

load share input that ensures that all units connected in parallel carry an equal

share of the load.

DC-DC CONVERTERS

- Force cooled.

- Thermally protected.

- Input/output voltage

and current protected.

- Wide input voltage range.

- Serial alarm and control interface.

- Microprocessor controlled.

Page 42: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 4�

CM SERIES 1.7kW MODULAR DC-DC CONVERTERS

DC Input CM1760-48 CM1748-60 CM1748-48Nominal Input Voltage: 48V 60V 48VInput Voltage Range: 40-60V 52-74V 40-60VInput Protection: Fuses: Fuse in the positive input with crowbar diode. Input Voltage: Converter shuts down when input voltage is out of range, Automatically restarts when correct voltage is restored.

DC Output CM1760-48 CM1748-60 CM1748-48Nominal Output Voltage: 60V 48V 48V Output Voltage Range: 57-65V 46-52V 46-52VMaximum Output Current: 27A 33A 33AMaximum Output Power: 1700W 1700W 1700WEfficiency: 91% 91% 91%Regulation: Line: ± 0.1% Load: ± 0.5% (no load to full load)Start-up Time: Walk-in delay 2-8 seconds depending on load.Protection: Current Limit: Adjustable to 50-100% of maximum rated current. Over Temperature: Auto current turndown, backup shutdown protection. Polarity Reversal: Output fuse in positive with crowbar diode. Over Voltage: Adjustable limit.Noise: (under nominal conditions) Ripple <100Hz: <1mV rms unweighted Voice Band 100Hz-5KHz: <1mV rms psophometric Wide Band 5kHz-1MHz: <5mV rms unweighted Peak to Peak 0-20MHz: <50mV peak to peak Isolation: Input to Output: 4230V DC Input to Chassis: 2115V DC (VDR to chassis removed) Output to Chassis: 2115V DC

Environmental RequirementsAmbient Temperature: Nominal: +25 +/- 5ºC Range: -10 to +70ºC (maximum output power is derated above +50ºC) Storage Temperature: -20 to +70ºCHumidity: 5-95% RH (non condensing)Altitude: <2500m, De-rate maximum ambient temperature by +4ºC per 1000m above sea level.

MechanicalDimensions W, H, D: 111.5mm, 44mm (1U), 282 overall (rack depth 260mm)Weight: 1.1kg Shipping Dimensions W, H, D: 170mm, 52mm, 325mmShipping Weight: 1.6kgCooling: Forced cooled.

CompliancesSafety: EN60950Electostatic Discharge: CISPR24Radiated Radio Frequency: CISPR22

Additional Accesories ACM-4T: 1U 4 position DC-DC converter shelf, no cables.

Part NumbersCM1760-48: 1.7kW 48 to 60V DC modular DC-DC converter.CM1748-60: 1.7kW 60 to 48V DC modular DC-DC converter.CM1748-48: 1.7kW 48 to 48V DC modular DC-DC converter.

Page 43: Enatel Limited - Product Catalogue 2010 v1.0

44 | ENATEL | 2010 PRODUCT CATALOGUE

CM SERIES 500W to 1.0kW MODULAR DC-DC CONVERTERS

DC Input CM1048-24 CM1024-48 CM648-24 CM624-48 CM612-48Nominal Input Voltage: 24V 48V 24V 48V 48VInput Voltage Range: 20-30V 40-60V 20-30V 40-60V 40-60Input Protection: Fuses: Fuse in the positive input with crowbar diode. Input Voltage: Converter shuts down when input voltage is out of range, Automatically restarts when correct voltage is restored.

DC Output CM1048-24 CM1024-48 CM648-24 CM624-48 CM612-48Nominal Output Voltage: 48V 24V 48V 24V 12V Output Voltage Range: 46-52V 22-26V 46-52V 22-26V 11-14VMaximum Output Current: 21.6A 43A 13.5A 25A 40AMaximum Output Power: 1040W 1040W 650W 650W 560WEfficiency: 91% 91% 91% 91% 89%Regulation: Line: ± 0.1% Load: ± 0.5% (no load to full load)Start-up Time: Walk-in delay 2-8 seconds depending on load and output voltage.Protection: Current Limit: Adjustable to 50-100% of maximum rated current. Over Temperature: Auto current turndown, backup shutdown protection. Polarity Reversal: Output fuse in positive with crowbar diode. Over Voltage: Adjustable limit.Noise: (under nominal conditions) Ripple <100Hz: <1mV rms unweighted Voice Band 100Hz-5KHz: <1mV rms psophometric Wide Band 5kHz-1MHz: <5mV rms unweighted Peak to Peak 0-20MHz: <50mV peak to peak Isolation: Input to Output: 4230V DC Input to Chassis: 2115V DC (VDR to chassis removed) Output to Chassis: 2115V DC

Environmental RequirementsAmbient Temperature: Nominal: +25 +/- 5ºC Range: -10 to +70ºC (maximum output power is derated above +50ºC) Storage Temperature: -20 to +70ºCHumidity: 5-95% RH (non condensing)Altitude: <2500m, De-rate maximum ambient temperature by +4ºC per 1000m above sea level.

MechanicalDimensions W, H, D: 111.5mm, 44mm (1U), 282 overall (rack depth 260mm)Weight: 1.1kg Shipping Dimensions W, H, D: 170mm, 52mm, 325mmShipping Weight: 1.6kgCooling: Forced cooled.

CompliancesSafety: EN60950Electostatic Discharge: CISPR24Radiated Radio Frequency: CISPR22Other: CE & RoHS compliant

Additional Accesories ACM-4T: 1U 4 position DC-DC converter shelf, no cables.

Part NumbersCM1048-24: 1.0kW 24 to 48V DC modular DC-DC converter.CM1024-48: 1.0kW 48 to 24V DC modular DC-DC converter.CM648-24: 650W 24 to 48V DC modular DC-DC converter.CM624-48: 650W 48 to 24V DC modular DC-DC converter.CM612-48: 560W 48 to 12V DC modular DC-DC converter.

Page 44: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 45

Enatel offer a range of supervisory modules and monitoring options, which have

been designed to work with our power products. Allowing for easy integration

into our complete DC power systems solutions for telecommunications and data

networking applications.

MONITORING

- Temperature compensation.

- LVD control.

- Setup from front panel.

- Boost control and timer.

- LCD display of parameters.

Page 45: Enatel Limited - Product Catalogue 2010 v1.0

46 | ENATEL | 2010 PRODUCT CATALOGUE

SM�6 SUPERVISORY MODULE

InputVoltage: 16-75V DCCurrent: <150mA maximum.

InterfaceDisplay: 4 line x 16 character multi-lingual alpha numeric display.Communications: Serial: 1x USB port on front panel for local PC interface. 1x RS232 port, rear mounted for remote serial/modem communications. Relay: 6xalarmandcontrolrelays,fiveofwhichcanbemappedforcustomized alarm settings. (extra available with I/O expansion board) TCP/IP: Ethernet interface for communication using SNMP protocol and internal webbasedconfigurator. LVD: 3x standard or 2x pulse control LVD contacts. (for magnetically latched LVD contactors)Indicators: 3x LED’s: Green - power on/monitor OK. Yellow - non urgent alarm. Red - urgent alarm. Audible: 90dBAbuzzermappabletouserdefinedconditions. Controls: 3x push buttons for parameter setting or viewing on front panel.SignalInputs: 2xserialbusesforrectifiercontrolandinterfacetoperipheralmodules. 10x general purpose inputs. (6x for customer connection, 4x reserved for internal system connection.) 4x battery MCB sensors. (reserved for internal system connection.) 3x current shunt inputs. (reserved for internal system connection.) 1x DC voltage inputs. (reserved for internal system connection.) Alarms: 6x alarm relays.Alarm Contacts: 0.3A 100V volts free changeover contacts.Default Alarm Map: Relay 1: Monitor fail. (non programmable.) Relay 2: Non-urgent. (programmable.) Relay 3: Urgent. (programmable.) Relay 4 - 6: Unassigned.Logging Capacity: Periodic Log: Typically 16000 records. (dependant on number of parameters logged.) Event Log: Typically 16000 records. (dependant on number of parameters logged.)Battery Mid-point Monitoring: 3x strings with individual string currents. (more available with shared string currents.)

PhysicalDimensions, W, H, D: 111.5mm , 44mm (1U), 265mm overall (rack depth 244mm)Weight: 365gConnections: Relay outputs, mini combicon to accept 1.5mm csa wire. Serialcommunicationstorectifiershelf&peripheraldevices-RJ45. USB port - USB mini B.Operating Temperature: -25 to +55°CStorage Temperature: -50 to +85°C CompliancesRadiated Emissions: EN55022RF Susceptibility: EN55024

Optional Accessories ACA-TC3C: 3m temperature sensor and cable.ACA-TC7C: 7m temperature sensor and cable.ASM-AC3P: 3 phase AC voltage and current monitor.ASM-ABM-24: Battery condition monitor, 24 blocks. (maximum 4x BCM cards)ASM-SM36IO: Standard I/O expansion board (maximum of 4 per supervisory module.) Voltage Range: 15-75V DC Current: <150mA maximum Connection: Connectsviarectifierserialbus,2xRJ45. Alarms: Up to 8x alarm and control relays, able to be mapped for customized alarm settings. Signal Inputs: Up to 6x digital inputs. Up to 6x analogue inputs. Operating Temperature: -25 to +55°C Storage Temperature: -50 to +85°C

Part NumbersSM36-00: Standard 1U modular controller, 6x relays, 6x digital inputs.SM36-00-1U: Standard 1U x 19” mounting version controller, 6x relays, 6x digital inputs.SM36-10-1U: Standard 1U x 19” mounting version controller, 6x relays, 6x digital inputs; with standard I/O expansion board.SM36-00-PM: Standard panel mount version controller, 6x relays, 6x digital inputs.SM36-10-PM: Standard panel mount version controller, 6x relays, 6x digital inputs; with standard I/O expansion board.

LVD dual lvd control.

WEB web based configurator.

USB usb port for local connection.

Page 46: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 47

SM�5 SUPERVISORY MODULE

InputVoltage: 16-75V DCCurrent: <150mA maximum.

InterfaceDisplay: 4 line x 16 character multi-lingual alpha numeric display.Communications: Serial: 1x USB port on front panel for local PC interface. Relay: 6xalarmandcontrolrelays,fiveofwhichcan be mapped for customized alarm settings. LVD: 3x standard or 2x pulse control LVD contacts. (for magnetically latched LVD contactors)Indicators: 3x LED’s Green - power on/monitor OK. Yellow - non urgent alarm. Red - urgent alarm. Audible: 90dBAbuzzermappabletouserdefinedconditions. Controls: 3x push buttons for parameter setting or viewing on front panel.SignalInputs: 2xserialbusesforrectifiercontrolandinterfacetoperipheralmodules. 10x general purpose inputs. (6x for customer connection, 4x reserved for internal system connection.) 4x battery MCB sensors. (reserved for internal system connection.) 3x current shunt inputs. (reserved for internal system connection.) 1x DC voltage inputs. (reserved for internal system connection.) Alarms: 6x alarm relays.Alarm Contacts: 0.3A 100V volts free changeover contacts.Default Alarm Map: Relay 1: Monitor fail. (non programmable.) Relay 2: Non-urgent. (programmable.) Relay 3: Urgent. (programmable.) Relay 4 - 6: Unassigned.Logging Capacity: Periodic Log: Typically 16000 records. (dependant on number of parameters logged.) Event Log: Typically 16000 records. (dependant on number of parameters logged.)Battery Mid-point Monitoring: 3x strings with individual string currents. (more available with shared string currents.)

PhysicalDimensions, W, H, D: 111.5mm , 44mm (1U), 265mm overall (rack depth 244mm)Weight: 325gConnections: Relay outputs, mini combicon to accept 1.5mm csa wire. Serialcommunicationstorectifiershelf&peripheraldevices-RJ45. USB port - USB mini B.Operating Temperature: -25 to +55°CStorage Temperature: -50 to +85°C CompliancesRadiated Emissions: EN55022RF Susceptibility: EN55024

Optional Accessories ACA-TC3C: 3m temperature sensor and cable.ACA-TC7C: 7m temperature sensor and cable.ASM-AC3P: 3 phase AC voltage and current monitor.ASM-ABM-24: Battery condition monitor, 24 blocks. (maximum 4x BCM cards.)ASM-SM3XIO: Standard I/O expansion board (maximum of 4 per supervisory module.) Voltage Range: 15-75V DC Current: <150mA maximum Connection: Connectsviarectifierserialbus,2xRJ45. Alarms: Up to 8x alarm and control relays, able to be mapped for customized alarm settings. Signal Inputs: Up to 6x digital inputs. Up to 6x analogue inputs. Operating Temperature: -25 to +55°C Storage Temperature: -50 to +85°C

Part NumbersSM35-00: Standard 1U modular controller, 6x relays, 6x digital inputs.SM35-00-1U: Standard 1U x 19” mounting version controller, 6x relays, 6x digital inputs.SM35-10-1U: Standard 1U x 19” mounting version controller, 6x relays, 6x digital inputs; with standard I/O expansion board.SM35-00-PM: Standard panel mount version controller, 6x relays, 6x digital inputs.SM35-10-PM: Standard panel mount version controller, 6x relays, 6x digital inputs; with standard I/O expansion board.

126 serial control for up to 126 rectifiers/

converters plus peripheral devices.

LCD lcd display.

USB usb port for local connection.

Page 47: Enatel Limited - Product Catalogue 2010 v1.0

48 | ENATEL | 2010 PRODUCT CATALOGUE

SM�2 SUPERVISORY MODULE

InputVoltage: 16-75V DCCurrent: <150mA maximum.

InterfaceDisplay: 4 line x 16 character multi-lingual alpha numeric display.Communications: Serial: 1x USB port on front panel for local PC interface. 1x RS232 port, rear mounted for remote serial/modem communications. Relay: 3x alarm and control relays, two of which can be mapped for customized alarm settings. (extra available with I/O expansion board) TCP/IP: Ethernet interface for communication using SNMP protocolandinternalwebbasedconfigurator. LVD: 3x standard or 2x pulse control LVD contacts. (for magnetically latched LVD contactors)Indicators: 3x LED’s Green - power on/monitor OK. Yellow - non urgent alarm. Red - urgent alarm. Audible: 90dBAbuzzermappabletouserdefinedconditions. Controls: 3x push buttons for parameter setting or viewing on front panel.SignalInputs: Serialbusforrectifiercontrolandinterfacetoperipheralmodules. Fuse fail. 5x spare digital inputs. 2x temperature sensors. 3x current shunts. 2x DC voltage inputs.Alarms: 3x alarm relays.Alarm Contacts: 0.3A 100V volts free changeover contacts.Default Alarm Map: Urgent. Non-urgent. Monitor fail.Logging Capacity: Periodic Log: 16384 records. (dependant on number of parameters logged.) Event Log: 16384 records. (dependant on number of parameters logged.)

PhysicalDimensions, W, H, D: 111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)Weight: 1.5kgConnections: Relay outputs, mini combicon to accept 1.5mm csa wire. Serialcommunicationstorectifiershelf&peripheraldevices-RJ45. USB port - USB mini B.Operating Temperature: -25 to +55°CStorage Temperature: -50 to +85°C CompliancesRadiated Emissions: EN55022RF Susceptibility: EN55024

Optional Accessories ACA-TC3C: 3m temperature sensor and cable.ACA-TC7C: 7m temperature sensor and cable.ASM-AC3P: 3 phase AC voltage and current monitor.ASM-ABM-24: Battery condition monitor, 24 blocks. (maximum 4x BCM cards.)ASM-SM3XIO: Standard I/O expansion board (maximum of 4 per supervisory module.) Voltage Range: 15-75V DC Current: <150mA maximum Connection: Connectsviarectifierserialbus,2xRJ45. Alarms: Up to 8x alarm and control relays, able to be mapped for customized alarm settings. Signal Inputs: Up to 6x digital inputs. Up to 6x analogue inputs. Operating Temperature: -25 to +55°C Storage Temperature: -50 to +85°C

Part NumbersSM32-00: Standard 1U modular controller, 3x relays, 6x digital inputs.SM32-10: Standard 1U modular controller, 3x relays, 6x digital inputs; with standard I/O expansion board mounted onto baseplate metalwork.SM32-00-1U: Standard 1U x 19” mounting version controller, 3x relays, 6x digital inputs.SM32-10-1U: Standard 1U x 19” mounting version controller, 3x relays, 6x digital inputs; with standard I/O expansion board.SM32-00-PM: Standard panel mount version controller, 3x relays, 6x digital inputs.SM32-10-PM: Standard panel mount version controller, 3x relays, 6x digital inputs; with standard I/O expansion board.

LVD dual lvd control.

WEB web based configurator.

USB usb port for local connection.

Page 48: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 49

SM�1 SUPERVISORY MODULE

InputVoltage: 16-75V DCCurrent: <150mA maximum.

InterfaceDisplay: 4 line x 16 character multi-lingual alpha numeric display.Communications: Serial: 1x USB port on front panel for local PC interface. Relay: 3x alarm and control relays, two of which can be mapped for customized alarm settings. LVD: 3x standard or 2x pulse control LVD contacts. (for magnetically latched LVD contactors)Indicators: 3x LED’s Green - power on/monitor OK. Yellow - non urgent alarm. Red - urgent alarm. Audible: 90dBAbuzzermappabletouserdefinedconditions. Controls: 3x push buttons for parameter setting or viewing on front panel.SignalInputs: 2xserialbusesforrectifiercontrolandinterfacetoperipheralmodules. Fuse fail. 5x spare digital inputs. 2x temperature sensors. 3x current shunts. 2x DC voltage inputs. Alarms: 3x alarm relays.Alarm Contacts: 0.3A 100V volts free changeover contacts.Default Alarm Map: Urgent. Non-urgent. Monitor fail.Logging Capacity: Periodic Log: 16384 records. (dependant on number of parameters logged.) Event Log: 16384 records. (dependant on number of parameters logged.)

PhysicalDimensions, W, H, D: 111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)Weight: 1.5kgConnections: Relay outputs, mini combicon to accept 1.5mm csa wire. Serialcommunicationstorectifiershelf&peripheraldevices-RJ45. USB port - USB mini B.Operating Temperature: -25 to +55°CStorage Temperature: -50 to +85°C CompliancesRadiated Emissions: EN55022RF Susceptibility: EN55024

Optional Accessories ACA-TC3C: 3m temperature sensor and cable.ACA-TC7C: 7m temperature sensor and cable.ASM-AC3P: 3 phase AC voltage and current monitor.ASM-ABM-24: Battery condition monitor, 24 blocks. (maximum 4x BCM cards.)ASM-SM3XIO: Standard I/O expansion board (maximum of 4 per supervisory module.) Voltage Range: 15-75V DC Current: <150mA maximum Connection: Connectsviarectifierserialbus,2xRJ45. Alarms: Up to 8x alarm and control relays, able to be mapped for customized alarm settings. Signal Inputs: Up to 6x digital inputs. Up to 6x analogue inputs. Operating Temperature: -25 to +55°C Storage Temperature: -50 to +85°C

Part NumbersSM31-00: Standard 1U modular controller, 3x relays, 6x digital inputs.SM31-10: Standard 1U modular controller, 3x relays, 6x digital inputs; with standard I/O expansion board mounted onto baseplate metalwork.SM31-00-1U: Standard 1U x 19” mounting version controller, 3x relays, 6x digital inputs.SM31-10-1U: Standard 1U x 19” mounting version controller, 3x relays, 6x digital inputs; with standard I/O expansion board.SM31-00-PM: Standard panel mount version controller, 3x relays, 6x digital inputs.SM31-10-PM: Standard panel mount version controller, 3x relays, 6x digital inputs; with standard I/O expansion board.

126 serial control for up to 126 rectifiers/

converters plus peripheral devices.

LCD lcd display.

USB usb port for local connection.

Page 49: Enatel Limited - Product Catalogue 2010 v1.0

50 | ENATEL | 2010 PRODUCT CATALOGUE

SM11 SUPERVISORY MODULE

InputVoltage: 35-60V DCCurrent: <85mA maximum.

InterfaceDisplay: 6 character starburst.Communications: Interfaceswithupto6xRFseriesrectifiers. Serial: RS232serialfordownloadingconfigurationfiles. Relay: 7x alarm and control relays.Indicators: 8x LED.Controls: 3x push buttons for parameter setting on front panel.SignalInputs: Externalshutdown.Fusefail.Rectifierfail.Mainsfail. Rectifieroffnormal.2xvoltmeter.2xcurrentmeter.(100mV)Alarms: 7x alarm relays.Alarm Contacts: 1A 100V volts free changeover contacts.AlarmList: Offnormal.Rectifierfail.Mainsfail.Floathigh.Floatlow. LVD. (control line for external LVD contactor)

PhysicalDimensions W, H, D: 275mm, 44mm (1U), 104mmWeight: 0.55kgConnections: Mini combicon to accept 1.5mm csa wire.Operating Temperature: -25 to +55°CStorage Temperature: -50 to +85°C

VersionsSM11-12: 12V SM11-24: 24VSM11-48: 48V

AccessoriesTemp Sensor: ACA-TC2U: 2 metre temp sensor and cable. ACA-TC7U: 7 metre temp sensor and cable.RectifierInterface: ACA-Alarm0.5: 500mm RJ45 patch cable.Current Sensor: ACS-S150: 150 Amp 100mV shunt assembly.

TEMP temperature compensation.

LVD lvd control.

LCD lcd display of parameters.

The optional fan controller module allows the smart control of four 24V or 48V

fans with fan stall detection.

Up to two fan controller modules can be connected in a system, giving a total of

8 controlled fans. Each module operates individually and has separate settings,

so can have different temperature set points and operate at different speeds.

The fans on one module all operate at the same speed.

FAN CONTROLLER BOARD

- Uses the SM�X temp sensor

to control fan speed.

- Individual minimum fan speed

configurable to prevent fan stall.

- 4x fans controlled per module

and up to 2x modules per system.

Input Voltage Range: 16-75V DC Fan Voltage: 12V, 24V, 48V & 60V DCMaximum Fan Current: 300mA maximum per fan connection.

Number Of Fans Controlled: 4x per fan controller module. (8x per system)Number Of Modules On Bus: 2x per system. Temperature Control Range: The range of the SM3X temp sensor. Communications: Enatel serial bus interface. Alarms: Controlled via SM3X fan fail.

Dimensions, W, H, D: 90mm, 67mm, 25mmWeight: 61g Part Number:Fan Controller Board: ASM-FCM4

Page 50: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 51

The Enatel BCM consists of peripheral circuit boards that can be added to an

Enatel system utilizing the SM22, SM�2 or SM�6 supervisory module to monitor

the performance of the installed stand-by battery system.

The monitor is designed to be connected to a number of different battery

configurations with minimal changes to its configuration.

The BCM includes the capability to log battery parameters during discharge

and on a periodic time basis.

BATTERY CONDITION MONITOR

- Compatible with SM22, SM�2

or SM�6 supervisory modules.

- 26 voltage inputs.

- 8 pairs of current inputs.

- 4 temperature inputs.

- Discharge logging.

- Periodic logging.

- Ease of installation.

- Compact design.

Voltage Resolution: 0.01VVoltage Accuracy: ± 0.02VCurrent Resolution: 1ACurrent Accuracy: ± 2A Temperature: ±2˚C(standardsensor,upgradedsensoravailablefor±1˚C) StandardConfigurations: 4strings,4voltagemeasurementsperstring.(requires1xPCB) 8 strings, 2 voltage measurements per string. (requires 1x PCB) 1 string, 24 voltage measurements per string. (requires 1x PCB) 1 string, 12 voltage measurements per string. (requires 1x PCB) 8 string, 4 voltage measurements per string. (requires 2x PCBs) Communications: Enatel serial bus interface. Alarms: Controlled via SM22, SM32 or SM36. Voltage symmetry fault. (based on deviation from average string block measurement) Battery current imbalance. (based on deviation from average string current across all strings in system) Battery temperature high. Battery temperature low. Battery string open. (detects string voltage deviation from system DC bus to conclude battery is disconnected from system) Data Logging: Utilization of supervisory module memory: SM22: 15,500 data points. SM32: 196,000 data points. Actual number of discharge events stored depends on frequency of discharges, logging interval and parameters measured.

Mechanical Dimensions, W, H, D: 80mm , 145mm, 27mmWeight: 100g Part NumberBattery Condition Monitor: ASM-ABM-24

The AC mains monitor can be added to the SM range of supervisory modules if

AC supply metering is required.

AC MAINS MONITOR

- Compatible with SM range

of supervisory modules.

- Ease of installation.

- Compact design.

Communications: Enatel serial bus interface.

Alarms: Controlled via SM21, SM22, SM31, SM32, SM35 or SM36. Voltage phase high, voltage phase low, voltage phase lost. (separate alarms for each phase). AC phase current high. (common alarm for all phases) Frequency high, frequency low. Mechanical Dimensions, W, H, D: 145mm, 15mm, 85mmWeight: 61.5g Part NumberAC Mains Mointor: ASM-AC3P

Page 51: Enatel Limited - Product Catalogue 2010 v1.0

52 | ENATEL | 2010 PRODUCT CATALOGUE

FTTX POWER SOLUTIONS

EPON INFRASTRUCTURE

Enatel have recognised the need for DC Power Supplies specifically sized

for Fibre to the Home requirements and developed a range of standalone and

modular rectifiers and Micro Compact Power Shelves to suit every application

within the FTTX environment. Be it Central Office or Customer Premise we

have the power solution to fit.

CENTRAL OFFICE APPLICATIONS

Experience shows that the majority of Central Office OLT units have a power

consumption of up to 1600W.

Enatel’s Micro Compact Power System is perfect for this application having

� x 800W rectifiers gives an N+1 redundancy solution, built in distribution

and full configured Supervisory Module.

OFFICE / APARTMENT APPLICATIONS

These ONT’s range in power consumption from 60W to 500W, typically have

dual DC feeds and are 19” rack mountable.

Enatel’s Micro Compact range with 200W and 400W modules are purpose

built for this application, giving optimum power output with space for

redundancy and standby battery recharge in the event of an AC failure.

MICRO COMPACT POWER SYSTEM

Enatel’s new range of Micro Compact Power Systems utilize Enatel’s

intelligent controllers and modular rectifiers. With rectifier output ratings

of 200, 400 and 800W and Supervisory modules capable of Ethernet

communication as standard these 1U power shelves are ideal for FTTX

solutions. They offer output power in line with the OLT /ONU usage and

have the capacity for N+1 redundancy. With various output distribution

options they cater to all the requirements of this growing market.

- Micro compact size means more room

for revenue generating equipment.

- World leading power density.

- Fully featured telecom grade rectifiers.

- Network monitoring available.

- Modular 19”/515mm ETSI design for ease of installation.

- High reliability means less cost of maintenance.

- Full remote monitoring available

means less site visits and less cost.

- Easily customized and configured to

suit each customers individual needs.

SOHO / RESIDENTIAL APPLICATIONS The SOHO (Small Office/Home Office) and residential market is going to have

the largest requirement for DC systems. If the customer premise is fitted

with alarms, nurse call or any other monitored device they will need a battery

backed DC supply to ensure communication is available during an AC outage.

Enatel have two solutions to suit these applications:

nSURE NS�00-12

For the SOHO Client Enatel’s nSURE NS�00-12 can provide long term

backup for all their communications needs.

SOHO (Small Office/Home Office) clients with security systems will need

Enatel’s nSURE NS�00-12 power supply. Couple into this the ONU, Security

system, residential gateway and wireless router and it can be business as

usual from a laptop during an AC outage. The NS�00-12 is wall mountable

and convection cooled making it ideal for office locations.

- 12V, �00W output.

- Mains fail alarm.

- Convection cooled.

- Wall mountable.

- Automatic float/boost charge cycle.

- Power factor corrected.

- Thermally protected.

- Input/output voltage and current protected.

nSURE NS�0-12

To suit the residential needs Enatel offers the nSURE NS�0-12 (with

integrated battery) for basic autodialer backup functionality.

For home owners with alarm auto dialers FTTH means their alarms will not be

monitored in the event of an AC Outage. Enatel’s nSURE NS�0-12 provides

battery backed power to the ONU even when the lights go out. Security or

Nurse call devices will operate as normal.

- Telecom grade 12V DC (�0W max.) output.

- Up to 8 hours* of standby battery backup.

- Flexibility of wall or desktop mount.

- Easy user replaceable battery without power interruption.

- Microprocessor based intelligent control.

- Cold start capable.

- Local audible and visual indicators with remote alarms.

- Optional extended runtime.

AC POWER SOLUTIONS

As some FTTX equipment is AC powered Enatel can also offer integrated

DC-AC Inverters, this allows for a telecommunications grade UPS (Long

backup times) on the entire FTTX system. The Inverters are monitored and

controlled through the same controller as the rest of the DC Power system.

Enatel can supply the complete solution in a wall mount cabinet or ready to

integrate into the OLT/ONU mounting system.

Page 52: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 5�

nSURE 1U MICRO COMPACT SYSTEM 0.8 - 2.4KW 48V DC

AC Input: Single phase.

AC Current: 170V AC, 15.0A max. 230V AC, 11.1A nominal.

(refer to RM8xx, series brochures for full details)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full load)

Termination: Singlephase,1.5mflyinglead.

DC Output

Nominal Voltage: -48V

Rated System Output Power: 2400W max. (50A @ -48V; 44.4A @ -54.0V)

Polarity: Positive earth. (negative earth available to special order).

DC Distribution:

Load: 2x 10A, 2x 20A load circuit breakers.

Battery: 2x 30A battery circuit breakers.

Breaker Fail Detection: Electronic fail detection on both load and battery breakers.

DC Terminals (Front Connected):

Load: 6mm² push-in spring cage.

Battery: 55A power-pole plug-in connectors..

LowVoltageDisconnect: 50AbatteryLVD(magneticallylatching)fittedasstandard.

Mechanical

Dimensions,W,H,D: 482.6mm(standard19”module),alsofits

ETSI 515mm mounting cabinet, 44.45mm (1U, 1.75”), 285mm (11.6”)

Weight: 5kg(excludingrectifiermodules)

Shipping Dimensions, W,H,D: 540mm, 95mm, 400mm

Weight: 6kg(excludingrectifiermodules)

Monitoring & Control: Various monitoring options are available via the Enatel SM35/36 series

of control & supervisory modules. Standard features include full

temperature compensation, automated and manual battery testing/

equalisation, 6x general purpose inputs and 6x voltage-free relay alarm

outputs. For further details, refer to the SM35/36 series of brochures.

Accessories

ACA-BC08P2: 2m, 8mm Ø battery cable kit. (other lengths available to special order)

PartNumbers: Actualpartnumberswillvarywithconfiguration.

PSX1606211F-000: Microcompactsystem,2x800W48Vrectifiers,6xload

2x battery MCB’s, front termination, SM35 supervisory module.

PSX1606221F-000: Microcompactsystem,2x800W48Vrectifiers,6xload

2x battery MCB’s, front termination, SM36 supervisory module.

PSX2404211F-000: Microcompactsystem,3x800W48Vrectifiers,4xload

2x battery MCB’s, front termination, SM35 supervisory module.

PSX2404221F-000: Microcompactsystem,3x800W48Vrectifiers,4xload

2x battery MCB’s, front termination, SM36 supervisory module.

Supervisory ModuleSM36

RM848 RM848 RM848

48V nominal output voltage.

2.4kW maximum output power.

Page 53: Enatel Limited - Product Catalogue 2010 v1.0

54 | ENATEL | 2010 PRODUCT CATALOGUE

nSURE NS�00-12

AC InputNominal: 110/220V, 50/60HzVoltage Range: 100-275V AC (full power output), 85-100V AC (reduced power output) Frequency Range: 45-66Hz Power Factor: >0.99 (full load) Efficiency: 85% Input Fuses: HRC Fuses in phase & neutral.Maximum Input Current: 4AProtection: Input Voltage: Automatic shutdown, restarts automatically when correct voltage restored. Input Rush: <2x maximum input current.

DC OutputNominal Voltage: 12VRated Voltage: 14.5VVoltage Range: 11.5-15V Maximum Current: 20ARegulation: Line: ±0.1% Load: ±0.5% (no load to full load)Hold-up Time: >15ms for 20% output voltage drop.Start-up Time: Walk-in delay 2 seconds (depends on AC input voltage)Protection: Current Limit: Adjustable to 50-100% of maximum rated current. Over Temp: Automatic current turndown, backup shutdown protection. Polarity Reversal: Output fuse with crowbar diode. Over Voltage: Adjustable limit.Noise: (under nominal conditions) Ripple <100Hz: <5mV rms unweighted. Voice Band 100Hz to 5KHz: <0.5mV rms psophometric. Wide Band 5kHz to 1 MHz: <2.5mV rms unweighted. Peak to Peak 0 to 20MHz: <50mV p-p unweighted.Isolation: Input to Output: 3000V AC Input to Chassis: 2500V AC (VDR to chassis removed.) Output to Chassis: 1500V AC Environmental RequirementsNominal Ambient Temperature: 25+/-5°CRange: -10 to +60°CHumidity: 5-95% RH (non-condensing)Altitude: <2500m de-rate maximum ambient temperature by+4˚per1000mabovesealevel.

MechanicalDimensions, W, H, D: 311mm, 163mm, 62mmWeight: 1.5kgShipping Dimensions, W, H, D: 377mm, 235mm, 122mmShipping Weight: 2.4kgCooling: Convection cooled.Connections: Mains: IEC 320 universal connection. Output to Load: 4 way lumberg macromodule. Output to batteries: 4 way lumberg macromodule.

Standard FeaturesAutoFloat/Boost: Rectifierentersboostmodeatpowerup. Whenbatterycurrentreducestofloatthresholdlimit(adjustablefrom 0.1Ato40%MRC),unitrevertstofloatvoltagesetting.Wheninboost butoutofcurrentlimit,rectifierwillautomaticallyswitchbacktofloat after approximately four hours. Ifbatterycurrentexceedsthefloatthresholdlimitwhentherectifieris infloatmodeitwillautomaticallyswitchtoboostmode.AlarmandIndicatorControls: Opencollectorrectifierfail(via4k7resistor),Opencollectormainsfail.

Compliances: Safety: EN60950 Electrostatic Discharge: CISPR24 Radiated Radio Frequency: CISPR22 AC Harmonics: EN61000-3-2 AC Flicker and Fluctuation: EN61000-3-3

12V nominal output voltage.

300W maximum output power.

Page 54: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 55

nSURE NS�0-12

Input

Nominal Input Voltage: 120V AC/230V AC

Voltage Range: 80-260V AC

Frequency Range: 45Hz-65Hz

Plug Type: IEC inlet.

Output

Output Power (Max): 30W/2.2A

Normal Voltage: 12V DC

Output Voltage Range: 10.5-13.8V DC

LineModeEfficiency: >80%

Plug Type: 7pin terminal strip. (2 * DC output, 5 * dry contact alarms)

Battery

Type/Rating: 12V/7Ah x 1pc (12V/9Ah option)

Discharge Prevention: 10.5V ± 0.5V

Rated Charging Voltage: 13.7V ± 0.25

Recharge Time (Internal Battery): 4 hours to 90% without load after discharge.

Charge Current: 2.5A maximum.

Hot Swappable Battery: Yes.

Indicators

AC Mode: Solid green LED.

Backup Mode: Solid yellow LED.

Battery Low: Flashing yellow LED.

Battery Replace: Flashing red LED.

Battery Missing: Flashing red LED.

Fault: Flashing red LED.

Battery Self Test: Flashing green LED.

Audible Alarm

Backup Mode: 5 seconds.

Battery Low: 1 second.

Battery Replace: 2 seconds.

Battery Missing: Continuous.

Fault: Continuous.

Mute Function: Switch. (on/off)

Environment

Operating Temperature: 0 to 40°C

Operating Humidity: 0 to 90%

Operating Elevation: 0 to 3000m

Physical

Dimensions, W, H, D: 212mm, 216mm, 87mm

Weight: 4.0Kg

12V nominal output voltage.

30W maximum output power.

Page 55: Enatel Limited - Product Catalogue 2010 v1.0

56 | ENATEL | 2010 PRODUCT CATALOGUE

Based on our proven range of modular telecom power solutions, we have

developed a range of solutions for use in 110V DC industrial applications.

Systems are configured using Enatel’s state of the art high frequency switch

mode rectifier modules, intelligent network capable controllers, AC & DC

distribution modules, and cabinets, and can be customized and configured to

meet individual customer requirements.

For details on a Enatel power system that meets your requirements contact us.

INDUSTRIAL SOLUTIONS

- World leading power density.

- Fully featured telecom

grade rectifiers.

- Network monitoring available.

- Modular 19” design for ease

of installation.

- Includes AC surge protection.

- More room for revenue

creating equipment.

- Upgrade existing systems

to higher power.

- High reliability means less cost

of maintenance.

- Full remote monitoring available

means less site visits and less cost.

- Cost competitive.

- Suitable for more harsh

environments.

Page 56: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 57

2U ULTRA COMPACT SYSTEM �.0 - 6.0kW 110V DC

Supervisory ModuleSM34

BatteryLoadACInput

ULTRAHVcompact

ACInput: Singlephase90–300VAC

AC Current: 38A max / Ph (Ph-N) (refer to RM30110 brochure for full details)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full load)

Termination: Single phase, 16mm2 L, N, E tunnel terminals at rear.

Single phase surge protection. (40kA, 8/20µ sec)

DC Output

Nominal Voltage: 121.5V

Rated Voltage: 80-155V DC

Rated System Output Power: 6.0kW max @ 121.5V DC (50A)

Polarity: +60V / -60V

DC Distribution:

Load: 1x 63A 2 pole load MCB (breaks +ve & -ve)

35mm tunnel terminals at rear.

Battery: 1x 63A 2 pole battery MCB (breaks +ve & -ve)

35mm tunnel terminals at rear.

Breaker Fail Detection: Auxiliaries on both load and battery breakers.

EarthLeakageDetection: Configurableviasoftware,factorysetat25mA

Mechanical

Dimensions, W, H, D: 482.6mm (standard 19” module), 89mm (1U, 3.5”), 415mm (16.3”)

Weight: 7.5kg(excludingrectifiermodules)

Shipping Dimensions, W, H, D: 530mm, 154mm, 430mm

Weight: 9kg(excludingrectifiermodules)

Monitoring & Control: Various monitoring options are available via the Enatel SM33/34 series of

control & supervisory modules. Standard features include full temperature

compensation, automated and manual battery testing/equalisation and

three voltage-free relay alarm outputs.

PartNumbers: Actualpartnumberswillvarywithconfiguration.

PSC06021130-000: 2U HV Ultra Compact Power System

including standard SM33 supervisory module.

PSC06021140-000: 2U HV Ultra Compact Power System

including standard SM34 supervisory module.

110V nominal output voltage.

6.0kW maximum output power.

Page 57: Enatel Limited - Product Catalogue 2010 v1.0

58 | ENATEL | 2010 PRODUCT CATALOGUE

WALL MOUNT BATTERY CHARGER �.0kW 110V DC

AC Input: Single phase with surge protection and input 32A MCB

(refertorectifierbrochureforfulldetails)

Frequency Range: 45-66Hz

Power Factor: >0.99 (full load)

Termination: Single phase. Direct MCB termination for L. 10mm² N, E tunnel terminals.

Max Rated System

Output Power: 110V (80-155V DC)

3000W @ 120V DC, 27A max.

Polarity: Isolatedoutput.1xRM301103000Wrectifier.

DC Distribution:

Load: 1x 63A 2 pole MCB.

Battery: 1x 63A 2 pole MCB.

Breaker Fail Detection: Auxiliaries.

DC Terminals: Live: Direct MCB connections.

Weight: Approx. 10.5Kg

Dimensions, D, H, W: 620mm x 375mm x 80mm

Shipping Dimensions, D, H, W: 730mm x 470mm x 200mm

Monitoring and Control: Various monitoring options via the Enatel SM30 series of control &

supervisory modules. Standard features include full temperature

compensation, automated and manual battery testing/equalisation

and three voltage-free relay alarm outputs. For further details,

refer to the SM30 series of brochures.

Part Numbers: Actual part numbers will vary with congifuration.

PSW-3111030-000: Wall mount charger including standard SM33 supervisory module.

PSW-3111040-000: Wall mount charger including standard SM34 supervisory module.

110V nominal output voltage.

3.0kW maximum output power.

Page 58: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 59

AC InputNominal: 230VVoltage Range: 90-300V (reduced power below 175V)Frequency Range: 45-65 HzPower Factor: >0.99Efficiency: >92%(>45%outputpower)Input Fuses: HRC fuses in phase and neutral.Maximum Input Current: 19AProtection: Input Voltage: Auto shutdown, auto restart when correct voltage restored. Input Inrush: <2x maximum input current.

DC OutputOutput Ratings: Constant Current: 80-110V DC (27.3A) Constant Power: 110-155VD C (3.0kW) Nominal Voltage: 120V Rated Voltage: 145V Voltage Range: 80-155V Maximum Current: 27.3ARegulation: Line: ±0.1% Load: ±0.5% (no load to full load)Hold-up Time: >15ms for 20% output voltage drop.Start-up Time: Start up delay 1 second. (varies with AC supply voltage) Walk-in delay 6 seconds at full output. (varies with DC output voltage)Protection: Current Limit: Adjustable to 50-100% of maximum rated current. Over Temperature: Automatic current turndown, backup shutdown protection. Polarity Reversal: Output fuse with crowbar diode. Over voltage: Adjustable limit.Noise: (under nominal conditions) Ripple <100Hz: <1mV rms unweighted. Voice band 100Hz-5KHz: <2mV rms psophometric. Wide band 5kHz-1MHz: <5mV rms unweighted Peak to Peak 0-20MHz: <200mV peak to peak.Isolation: Input to Output: 4000V DC Input to Chassis: 3500V DC (VDR to chassis removed) Output to Chassis: 2100V DC

Environmental RequirementsAmbient Temperature: Nominal: 25+/-5ºC Range: -10ºC to +70ºC (maximum output power is derated above +50ºC)Storage Temperature: -20ºC to +70ºCHumidity: 5-95% RH (non-condensing)Altitude: <2500m, De-rate maximum ambient temperature by 4ºC per 1000m above sea level.

MechanicalDimensions, W, H, D: 41mm, 220mm, 305mm overall.Weight: 2.8kg Shipping Dimensions W, H, D: 52mm, 230mm, 340mmShipping Weight: 2.95kgCooling: Forced cooled, using dual temperature controlled high reliability fans.

CompliancesSafety: EN60950Electrostatic Discharge: CISPR24Radiated Radio Frequency: CISPR22AC Harmonics: EN61000-3-2 AC Flicker and Fluctuation: EN61000-3-3Other: CE & RoHS compliant.

RM�0110 �.0KW 110V DC MODULAR RECTIFIER

110V nominal output voltage.

3.0kW nominal output power.

27.3A maximum output current.

Page 59: Enatel Limited - Product Catalogue 2010 v1.0

60 | ENATEL | 2010 PRODUCT CATALOGUE

SM�4 SUPERVISORY MODULE

InputVoltage: 80-160V DCCurrent: <50mA maximum.

InterfaceDisplay: 4 line x 16 character multi-lingual alpha numeric display.Communications: Serial: 1x USB port on front panel for local PC interface. 1x RS232 port, rear mounted for remote serial/modem communications. Relay: 3x alarm and control relays, two of which can be mapped for customized alarm settings. TCP/IP: Ethernet interface for communication using SNMP protocolandinternalwebbasedconfigurator. LVD: 3x standard or 2x pulse control LVD contacts. (for magnetically latched LVD contactors)Indicators: 3x LED’s Green - power on/monitor OK. Yellow - non urgent alarm. Red - urgent alarm. Audible: 90dBAbuzzermappabletouserdefinedconditions. Controls: 3x push buttons for parameter setting or viewing on front panel.SignalInputs: Serialbusforrectifiercontrolandinterfacetoperipheralmodules. Fuse fail. 5x spare digital inputs. 2x temperature sensors. 3x current shunts. 2x DC voltage inputs.Alarms: 3x alarm relays.Alarm Contacts: 0.3A 100V volts free changeover contacts or 0.15A 160V volts free changeover contacts.Default Alarm Map: Urgent. Non-urgent. Monitor fail.Logging Capacity: Periodic Log: 16384 records. (dependant on number of parameters logged.) Event Log: 16384 records. (dependant on number of parameters logged.)

PhysicalDimensions, W, H, D: 111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)Weight: 1.5kgConnections: Relay outputs, mini combicon to accept 1.5mm csa wire. Serialcommunicationstorectifiershelf&peripheraldevices-RJ45. USB port - USB mini B.Operating Temperature: -25 to +55°CStorage Temperature: -50 to +85°C CompliancesRadiated Emissions: EN55022RF Susceptibility: EN55024

Optional Accessories ACA-TC3C: 3m temperature sensor and cable.ACA-TC3C: 7m temperature sensor and cable.ASM-AC3P110: 3 phase AC voltage and current monitor.ASM-ABM-24: Battery condition monitor, 24 blocks. (maximum 4x BCM cards.)

Part NumbersSM34-00: Standard 1U modular controller, 3x relays, 6x digital inputs.SM34-00-1U: Standard 1U x 19” mounting version controller, 3x relays, 6x digital inputs.SM34-00-PM: Standard panel mount version controller, 3x relays, 6x digital inputs.

LVD dual lvd control.

WEB web based configurator.

USB usb port for local connection.

Page 60: Enatel Limited - Product Catalogue 2010 v1.0

ENATEL | 2010 PRODUCT CATALOGUE | 61

SM�� SUPERVISORY MODULE

Input

Voltage: 80-160V DC

Current: <50mA maximum.

Interface

Display: 4 line x 16 character multi-lingual alpha numeric display.

Communications:

Serial: 1x USB port on front panel for local PC interface.

Relay: 3x alarm and control relays, two of which

can be mapped for customized alarm settings.

LVD: 3x standard or 2x pulse control LVD contacts.

(for magnetically latched LVD contactors)

Indicators:

3x LED’s Green - power on/monitor OK.

Yellow - non urgent alarm.

Red - urgent alarm.

Audible: 90dBAbuzzermappabletouserdefinedconditions.

Controls: 3x push buttons for parameter setting or viewing on front panel.

SignalInputs: 2xserialbusesforrectifiercontrolandinterfacetoperipheralmodules.

Fuse fail.

5x spare digital inputs.

2x temperature sensors.

3x current shunts.

2x DC voltage inputs.

Alarms: 3x alarm relays.

Alarm Contacts: 0.3A 100V volts free changeover contacts or

0.15A 160V volts free changeover contacts.

Default Alarm Map: Urgent.

Non-urgent.

Monitor fail.

Logging Capacity:

Periodic Log: 16384 records. (dependant on number of parameters logged.)

Event Log: 16384 records. (dependant on number of parameters logged.)

Physical

Dimensions, W, H, D: 111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)

Weight: 1.5kg

Connections: Relay outputs, mini combicon to accept 1.5mm csa wire.

Serialcommunicationstorectifiershelf&peripheraldevices-RJ45.

USB port - USB mini B.

Operating Temperature: -25 to +55°C

Storage Temperature: -50 to +85°C

Compliances

Radiated Emissions: EN55022

RF Susceptibility: EN55024

Optional Accessories

ACA-TC3C: 3m temperature sensor and cable.

ACA-TC7C: 7m temperature sensor and cable.

ASM-AC3P110: 3 phase AC voltage and current monitor.

ASM-ABM-24: Battery condition monitor, 24 blocks. (maximum 4x BCM cards.)

Part Numbers

SM33-00: Standard 1U modular controller, 3x relays, 6x digital inputs.

SM33-00-1U: Standard 1U x 19” mounting version controller, 3x relays, 6x digital inputs.

SM33-00-PM: Standard panel mount version controller, 3x relays, 6x digital inputs.

126 serial control for up to 126 rectifiers/

converters plus peripheral devices.

LCD lcd display.

USB usb port for local connection.

Page 61: Enatel Limited - Product Catalogue 2010 v1.0

62 | ENATEL | 2010 PRODUCT CATALOGUE© Copyright Enatel Limited 2010. Due to product development specifications are subject to change without prior notice. Pictures may be representative, actual products may differ.

Page 62: Enatel Limited - Product Catalogue 2010 v1.0

321 Tuam StreetPO Box 22-333ChristchurchNew Zealand

Phone +64-3-366 4550Fax +64-3-366 0884

Email [email protected]