Enclosure Power Management Solutions Basic PDU’s Metered (MD) PDU’s Intelligent PDU’s with: Strip Level Monitoring (W) Strip Level Monitoring & Socket Switching (WS) Socket Level Monitoring & Socket Switching (WSi) Single and Three Phase MONITOR CONTROL MANAGE Austin Hughes Europe Ltd | www.austin-hughes.eu | [email protected] | +44 (0) 2380 529303

Enclosure Power Management Solutions

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

EnclosurePower ManagementSolutions

• BasicPDU’s• Metered(MD)PDU’s• IntelligentPDU’swith:

• StripLevelMonitoring(W)

• StripLevelMonitoring&SocketSwitching(WS)

• SocketLevelMonitoring&SocketSwitching(WSi)

• SingleandThreePhase

MONITOR

CONTROLMANAGE

AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303

Features

WSi WS W MD BasicSwitched Switched Monitored Metered Basic

Outlet kWh PDU kWh PDU    Outlet Measurement Outlet Switch ON / OFF Latching Relay kWh Measurement Hot-pluggable Meter 2.8" Touchscreen DC Module SNMP Hardware Sensor Port x 2 (Temp & Humidity) Management Software 16 x PDU in Single Daisy Chain One IP Access 16 x PDU Levels Aggregate Amp Measurement Local Ammeter

Individual Fuse Option Vertical & Horizontal Mounting Multiple Outlet Configuration Tool-less Mounting Voltage: 110V / 208V / 250V Three Phase - Option Fuse / Circuit Breaker - Option Surge Protector - Option EMI Filter - Option

AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303

Need help choosing a PDU model? Find out more

InfraPower | PDU Range

Intelligent (W Series) PDUs: RackmountPDU’swithdigitallocaltouchscreendisplayandIPnetworkconnectivity.

WModel:StripLevelMonitoring.Reportingtheentire strip data, Amperes, kWh, Volts, PowerFactorandkWcentrally.

WSModel: Strip LevelMonitoring andSocketSwitching.TheaboveMonitored(W)functionalityinaddition to IPnetworkconnectivity toenableuserstoswitchorcontrolindividualoutletsorITequipmentwithinthecabinet.

WSiModel: SocketLevelMonitoringandSocketSwitching. IP network connectivity that allowsusers to switch individual outlets and meterindividualoutletorequipmentconsumption.

Basic PDU: Cost efficient and reliable rackmountpower distribution units which simplydeliver /distributepower fromoutsidethecabinettotheITequipment.

Metered (MD Series) PDU:MD Series PDUs allow true RMScurrent local monitoring via a digitalRMS ammeter.The blue LED displayis easy-to-read from a distance andallows rapid access to the aggregateloadonthecircuit.

FullrangeofAutomatic Transfer Switches (ATS)alsoavailable.

AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303

InfraPowerW SeriesIntelligentPDU’s|Features

Coloured ChassisA simple way to enhance cablemanagement and visualisation of thepower sources. Allows differentiationof primary and redundant power feeds(A&B) if required.Themost commoncombinationsareRed&BlueorBlack&GreyWhite.Othercoloursareavailable.

Field Replaceable DC Module

IP Dongle (SNMP)Hot pluggable IP dongle provides IP remoteaccess to the PDUs using a single IP addresschain.OnlyoneIPdongle isrequiredtoaccessamaximumof16PDUsinadaisychain.Simplyintegrate the IP dongle to the 1st PDU, thenthe entire daisy chain group can be remotelyaccessedoverIP.

FREE

ManagementSoftware

Hot Swappable MeterField replaceable RMS current meter with 2.8”colourLCDdisplaywithtouchscreenfunctionality.Thesharpandhighlyvisibledisplayprovideslocaldataof:• current(AMP)• voltage(Volt)• power(KW)• energyconsumption(KWh),• powerfactoroftheentirePDUThisdatahasameteringaccuracytowithin+/-1%.

Latching Relays*Toprotectmissioncriticalequipmentfrom unplanned downtime, socketswitching must be controlled viabistable/latchingrelays.Ensuringan‘alwayson’operationalperformanceandsocketstatusreturningtoaprepower outage after a planned orunplannedshutdown.

PDU Power Feed EntryBottom feed entry asstandard. Optional Topfeedentry.

*WS&WSiModelPDU’sonly

Available in Single Phase & Three Phase

ProtectionThermal Resettable Fuse• Protectedloadsegmentsfor

increasedreliability• Overloadresetbutton• Costeffectivesolutionfor

safetyoperation

Circuit Breakers (Option) • Protectedloadsegmentsfor

increasedreliability• Overloadswitch• Designedwithfullyshrouded

protectivecovertopreventaccidentalON/OFFoperation

Accidental Release SleevesIECSleevesofferaddedprotectionagainsttheunintentionalremovalof cables from the PDU C13 orC19outlets–see‘Accessories’

Environmental Sensor Ports2xenvironmentalplug inportsfor temperature and humiditymonitoring; all data is thendisplayedlocallyonthePDU.

Multiple Outlet ConfigurationsMultipleoutletconfigurationspereachindividualPDUe.g.OneVerticalPDUwith2xUK,20xC13,4xC19outlets

AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303

InfraPower | PDU Part Code Builder

VerticalButtonMountingKit

VerticalBracketMountingKit

MountingQuick and tool-less integration simplifies PDUinstallation.

Universalmountingkitssupportsallcabinetmodels

• Vertical Button Mounting Kit: Designed forglobal branded cabinets with keyhole typemountingholesontherearverticals

• Vertical Bracket Mounting Kit:EasyinstallationbymountingthePDUtothecabinetcabletray

BothaVerticalButtonMountingKit&VerticalBracketMountingKitaresuppliedasstandardperPDU.

Power Feed Entry AsstandardInfraPowerPDUs have bottompowerfeedentry.

Customisation to topfeed entry is availableonrequest.

Three Phase PDUsW Series Intelligent PowerDistributionUnitsareavailableinThreePhase

• Phasevoltagebalance

• PDUcascadingreducingdataportsandnetworkIPaddresses

• Zeropowerconsumptionlatchingrelayforoutletcontrol

• Switched/MonitoredPDUmodels

• Outlet/circuitlevelmeasurement

• Customconfigurationsavailable

Example PDU Configuration

AH V 02 3 20 1 04 2 2 7AH * ** * ** * ** * * *

AUSTIN HUGHES Direction

Socket Type 1 Socket Type 2 Socket Type 3Rating Model TypeQty Socket Type Qty Socket Type Qty Socket Type

AH V = Vertical 02 3 = UK 45° Sockets 02 1 = C13 Sockets 02 2 = C19 Sockets 1 = 13A 0 = BasicH = Horizontal 04 4 = UK 135° Sockets 04 If no C13 sockets

required insert ‘000’04 If no C19 sockets

required insert ‘000’

2 = 16A 1 = MD06 5 = UK 90° Sockets 06 06 3 = 32A 4 = W08 6 = CEE7/4 Schuko 08 08 4 = 10A 5 = WI 10 7 = Nema Sockets 10 10 5 = 20A 6 = WS12 8 = CEE7/5 Schucko 12 12 6 = 30A 7 = WSi16 If none of these socket

types required insert ‘000’

14 7 = 16A (3P)20 16 8 = 32A (3P) 24 18 9 = 63A

20 (3P = 3 Phase)24

283236

InfraPower|Options

Request a Quotation

3 1 1 1* * * *

Cord Length Input Plug Feed Input ColourOptional Extra

Protection Extra Requirement1 = 1 Meter 1 = 60309 Commando 1 = Bottom 1 = Black RAL 9005 1 = Circuit Breakers L = LSZH Input Cord2 = 2 Meter 2 = C20 IEC320 2 = Top 2 = Blue Pantone 200c 2 = Individually Fused E = External Earth Cord 3 = 3 Meter 3 = UK BS1363 3 = Red Pantone 300c 3 = EMI Filter S = Special Requirement4 = 4 Meter 4 = Schucko 4 = Grey White RAL 9002 4 = Resettable Individual Fuses K = Locking Sockets5 = 5 Meter 5 = Unterminated 5 = Yellow RAL 1018 5 = Surge Protection T = Transfer Switch6 = 6 Meter 6 = C14 IEC320 7 = Purple RAL 40067 = 7 Meter 7 = L6 20P Nema 8 = Orange RAL 10078 = 8 Meter 8 = L6-30P Nema 9 = Green RAL 60299 = 9 Meter0 = 10 Meter

Coloured Power Distribution Units ColouredPDUcasingsallowdifferentiationbetween primary and redundant powersources(generallyA&Bfeeds)withintheServerCabinet.Suggestedcombinations:

• LightGrey+StandardBlack

• Blue+Red

• Orange+Purple

• Yellow+Green

• Othercoloursareavailable

AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303

Socket ConfigurationsMultiple socket configurations are availableperPDU.

All sockets feature local port numberingusingnon-removablesilkscreenlabellingforidentificationandcircuitidentification.

ChoosecolourusingPDUPartCodeBuilderabove(BlackRAL9005asstandarddefault)

ProtectionResettable Fuse:Protectedloadsegmentsforincreasedreliability.Overloadresetbutton

Circuit Breakers:Protectloadsegmentsforincreasedliability,overloadswitch,designedwithfullyshroudedprotectivecovertopreventaccidentalon/off.

EMI Filter:Suppressesconductedinterferenceonasignal/powerline.Linefrequency:50/60HzAttenuation:Upto50dB

Surge Protection:Enhancesthedeviceprotection.Groundsunwantedvoltagesabovesafethreshold.

ChooseProtectiontypeusingPDUPartCodeBuilderabove(ThermalResettableFuseasstandarddefault)

Check out the InfraPower PDU Video

Example PDU ConfigurationAH V 02 3 20 1 04 2 2 7AH * ** * ** * ** * * *

AUSTIN HUGHES Direction

Socket Type 1 Socket Type 2 Socket Type 3Rating Model TypeQty Socket Type Qty Socket Type Qty Socket Type

AH V = Vertical 02 3 = UK 45° Sockets 02 1 = C13 Sockets 02 2 = C19 Sockets 1 = 13A 0 = BasicH = Horizontal 04 4 = UK 135° Sockets 04 If no C13 sockets

required insert ‘000’04 If no C19 sockets

required insert ‘000’

2 = 16A 1 = MD06 5 = UK 90° Sockets 06 06 3 = 32A 4 = W08 6 = CEE7/4 Schuko 08 08 4 = 10A 5 = WI 10 7 = Nema Sockets 10 10 5 = 20A 6 = WS12 8 = CEE7/5 Schucko 12 12 6 = 30A 7 = WSi16 If none of these socket

types required insert ‘000’

14 7 = 16A (3P)20 16 8 = 32A (3P) 24 18 9 = 63A

20 (3P = 3 Phase)24

283236

AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303

InfraPowerW SeriesIntelligentPDU’s|Connectivity

InfraPowerW SeriesIntelligentPDU’s|Software

IP Dongle & Daisy Chain Patented IP Dongle provides IP remote access tothePDUsbyatruenetworkIPaddresschain.Only1xIPdongleallowsaccesstomax.16PDUsinasingledaisychain.

Save the IP Address Cost of Your Data CenterInfraPowerManagerSoftware(IPM-04) issuppliedFree or utilise 3rd Party DCIM (via SNMP). Cost-efficient PDU management can be achieved byapplyingIPdongle&daisychain.

1 x IP Up to 16 PDU’s

Max. cabling distance between 2 x cascaded PDU’s up to 20 meters

InfraPowerManagerenhancesthebenefitsofWSeriesPDUsbydeliveringacentralisedremotemanagementplatform for thePDUs inmultipleIP-accessgroups.

The administrator can remotely manage thePDUsandtheenvironmentalsensorsconnectedbythewebbrowser.

• Widefunctionality

• ConciseMonitoringPages

• MassscalePDUmanagement

• Scalablesolution

• FlexibilitybyMultipleUsers

• Costeffective

InfraPower Manager Software (Free) UltrahighdensityPDUManagementcanbeachievedwithInfraPowerManager,theassociatedsoftwareforWSeriesPDUs.SupportingremotemanagementofmultiplePDUdaisychaingroups.

IPM-04: Supports up to 800 PDU’s (50 PDU Groups)

IPM-04providesthebasicfunctionsof:• Monitoringormeasurement ofAmps,Volts, kW,

kWh,PowerfactorandTemperature/Humidity

• RemoteswitchingON/OFFperindividualpoweroutlets

• Reporting

• Alarmsetting

• PDUOutletmeasurement

• Grouping and chart reporting (These functionsareprovidedbyhighersoftwareeditions)

ToarrangeaSoftwareDemonstrationplease Contact Us

External Door Mount PDU DisplayThe external door mount PDUdisplayprovidesahighlyvisiblelocaldisplaywithouttheneedtoopen the cabinet’s rear door toreadthePDU(s)information.

• External Door Mount PDUDisplayprovidesRJ-11portx2forPDUamp.&Temperaturemonitoring

• ThedisplaywillbeconnectedbacktoeachIPPDUviadooranda3mRJ-11cable

• Once connected, the reading of PDU ampsand temperature shows in the external doormountdisplay

IP Dongle• Patenteddesign

• Hotpluggableforeasyintegration

• AllowsIPremoteaccesstothePDUsbyasingleIPaddress

• OneIPdonglesupportsmax.16

• PDUsindaisychain

• Highlycosteffectivemethodto

accesstheintelligentPDUs

• SNMP

AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303

InfraPower|Accessories

Sensors• Externalsensoravailablewith

2Mor4Mcord

• Plugandplay

• Lowprofiledesignwithmagneticbaseforeasyaffixingtotherackcabinet

• PairofsensorscanbeconnectedtoonesingleWseriesPDUmeter

Accidental Release SleevesAvoids accidental removal of powerleadstoactiveequipmentbyengineersworkingwithinrackPDU’sC13andC19sockets.ByusingIECsleeves,apowercablerequires12Kgofforcetoremove.

Coloured Power CordsProvide the simplest way toenhance cablemanagementandvisualisepowersources.

IP DonglesAHAPDUIPD02S IP Dongle for Vertical PDU

AHAPDUIPDH02S IP Dongle for Horizontal PDU

Temperature & Humidity SensorsAH-IG-T012M Temperature Sensor, 2 MeterAH-IG-T014M Temperature Sensor, 4 Meter

AH-IG-TH012M Temperature & Humidity Sensor, 2 MeterAH-IG-TH014M Temperature & Humidity Sensor, 4 Meter

Accidental Release SleevesIEC_C13 C13 Cord Sleeves

IEC_C19 C19 Cord Sleeves

External Door Mount PDU DisplayAH-WS-DIS01 External PDU Display

C13-C14 CordsAHA111001 C13-C14 Black 1MAHA112001 C13-C14 Black 2MAHA113001 C13-C14 Black 3MAHA111002 C13-C14 Blue 1MAHA112002 C13-C14 Blue 2MAHA113002 C13-C14 Blue 3MAHA111005 C13-C14 Orange 1MAHA112005 C13-C14 Orange 2MAHA113005 C13-C14 Orange 3M

C19-C20 CordsAHA221001 C19-C20 Black 1MAHA222001 C19-C20 Black 2MAHA223001 C19-C20 Black 3MAHA221002 C19-C20 Blue 1MAHA222002 C19-C20 Blue 2MAHA223002 C19-C20 Blue 3MAHA221005 C19-C20 Orange 1MAHA222005 C19-C20 Orange 2MAHA223005 C19-C20 Orange 3M

Integrated Solutions

InfraPowerIntelligentWSeriesPDUscanbeincorporatedintoInfraSolutionXtoenablePDUmonitoringandcontrolinadditiontoSmartCardAccessandEnvironmentalManagement.

InfraSolutionXhasSNMPforoptionalintegrationtotheexistingDCIMofDataCentres.

Find out more

Automatic Transfer Switches

TocomplimentInfraPowerPDU’sacomprehensiverangeofAutomaticTransferSwitches(ATS)areavailable.

InfraPowerATSprovidesredundantpowerforsinglecordedequipmentwithautoswitchingrelayforseamlesspowertransfer.

Find out more

In-Line Meters

SingleandThreePhaseIn-LineMetersdesignedtoallowBasicPowerDistributionUnitstobeupgradedwithlocalmonitoringandremotemanagement.

Find out more

Thecompanyreservestherighttomodifyproductspecificationswithoutpriornoticeandassumesnoresponsibilityforanyerrorwhichmayappearinthispublication.

Allbrandnames,logosandregisteredtrademarksarepropertiesoftheirrespectiveowners.