Provider of Low and Medium Voltage Products

Overhead Insulation Piercing Connectors

TTD####XFBasic part number: con-nector with over-molded shear head and stainless

steel bolt, nut and washer.

TTD####XFTConnector with turbo

spacer

Sicame TTD Connector Features:

Installation : Simple, Fast and Reliable

• Determine direction for tap conductor to enter connector. Remove and discard the extra end cap.

• Insert tap conductor, • making sure con-

ductor is fully seated in end cap.

• Place connector on main conductor. Tighten screw(s) with a closed-end wrench or socket until the top shear-head breaks off.

TTD####XFB-TConnector with end cap position (splicing) and

turbo spacer.

1 2 3

Red ‘Turbo’ Spacer (FT)This feature allows the main wire to be in-serted and hand tightened, leaving the tap location completely open.

Splicing

Taps

Dead ends

Metering

FEATURES

• Easy installation – no cable

stripping

• Water tight connection

• Fully insulated, no exposed live

components

• UV stable

• Shear Bolt controls torque for

correct contact pressure

• Tinned copper teeth allow for

connections to either aluminum

or copper wire

TTD Series

APPLICATIONS

2

*Meets ANSI C119.4 and C119.5 Requirement 600 Volt Rated

*TTD5510XFBT

*TTD0510XF *TTD150XFT

TTD####XFB-T-UNIConnector with end cap

position (splicing), turbo spacer and blue insert

for use on bare wire.

*TTD2710XFBTUNI

TTD Series

Blue Rubber ‘UNI’ Insert (FBTUNI)This feature recreates insulation when used on bare wire. It is used to avoid any damage on neutral messenger. Remove this insert if the wire is insulated.

Overhead Insulation Piercing Connectors

TTD Series

4

Catalog Number

Conductor Size

14 12 10 8 6 4 3 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 700 750

TTD0510XFMainTap

TTD0810XFMainTap

TTD1010XFBTUNIMainTap

TTD1510XFTMainTap

TTD1810XFBTUNIMainTap

TTD2110XFBTUNIMainTap

TTD2610XFMainTap

TTD2710XFBTUNIMainTap

TTD4010XFBTMainTap

TTD4010XFTMainTap

TTD4310XFBTMainTap

TTD4510XFTMainTap

TTD5010XFBTMainTap

TTD5510XFBTMainTap

Part Number

Conductor RangeTorque in Inch lb.

Number of Bolts

Bolt Head Size in Inches

Qty. per Box

Current Rating Dimensions in Inches

Main AWG Tap AWGCU

AMPAL

AMPH W L

TTD0510XF 2/0 - 6 8 - 14 80 1 1/2 12 55 40 3.6 1.7 2.7

TTD0810XF 750 - 3/0 10 - 14 80 1 1/2 12 55 40 4.3 2.4 2.8

TTD1010XFBTUNI 1/0 - 8 2 - 10 80 1 1/2 12 190 150 3.7 2.0 3.0

TTD1510XFT 4/0 - 3 2 - 10 125 1 1/2 12 190 150 3.9 1.7 2.7

TTD1810XFBTUNI 1/0 - 8 1/0 - 8 125 1 1/2 12 190 150 3.7 2.0 3.0

TTD2110XFBTUNI 4/0 - 2 2/0 - 6 160 1 1/2 12 300 235 4.3 2.4 3.2

TTD2610XF 250 - 1 4/0 - 4 160 1 1/2 12 405 315 3.5 2.2 2.6

TTD2710XFBTUNI 4/0 - 2 4/0 - 4 160 1 1/2 12 405 315 4.4 2.4 3.2

TTD4010XFBT 350 - 1/0 350 - 1/0 330 2 5/8 4 570 445 5.4 3.1 5.0

TTD4010XFT 350 - 1/0 350 - 1/0 330 2 5/8 4 570 445 5.4 3.1 5.0

TTD4310XFBT* (500)350 - 2/0 4/0 - 4 330 2 5/8 4 405 315 5.4 3.1 5.0

TTD4510XFT 500 - 4/0 350 - 1/0 330 2 5/8 4 570 445 5.4 3.0 5.0

TTD5010XFBT 500 - 4/0 500 - 4/0 330 2 5/8 4 700 545 5.6 3.6 5.7

TTD5510XFBT* (750)500 - 250 500 - 250 330 2 5/8 4 700 545 5.6 3.6 5.7

MEDIUM VOLTAGE

TTDC454010FBA 4/0 - 1/0 4/0 - 1/0 220 2 5/8 3

TTDC455010FB 477 - 3/0 397 - 3/0 330 2 5/8 3

TTDC455310FA 477 - 3/0 3/0 - 2 330 2 5/8 3

*End cap on main side must be removed to reach maximum wire size shown in parenthesis

Note: Install with a 6 point socket

Note: Install with a 6 point socket

Ordering Information

Underground Insulation Piercing Connectors 6

Fully insulated, waterproof connector that

does not require stripping of the cable.

Piercing teeth allow for connections to either

aluminum or copper.

Ordering Information Piranha Series

Part Number Cable Range Number of Ports Qty. Per Box

PHM2-6-4/0

PHM2-14-1/0

PHS2-10-1/0

PHS-2-2-350

PHM3-12-1/0

PHM4-6-4/0T

PHM4-6-4/0B

PHMS4-6-4/0B

6 - 4/0

14 - 1/0

10 - 1/0

2 - 350

12 - 1/0

6 - 4/0

6 - 4/0

PHM5-250-350T

PHM5-250-350B

PHM5-6-4/0T

PHM5-6-4/0B

1/0 - 350

1/0 - 350

6 - 4/0

6 - 4/0

APPLICATIONS

FEATURES

PIRANHA Series

APPLICATIONS

• Connecting cables in pillar boxes

• Connections in underground pits

• Connections in streetlight columns

• Underground to overhead transi-

tions

• Buried service Connections

• Any ‘wet’ environment

• Waterproof

• Easy installation – no cable

stripping

• Fully insulated, no exposed live

components

• Shear Bolt controls torque for

correct contact pressure

• Flexible sealing cable ports that

are not affected by the angle of

cable entry

• Fitted with push-on protective

bolt caps

PHM5-4/0-500T

PHM6-6-350B

PHM6-6-500B*Also available in Transparent

4/0 - 500

2 @ 2 - 3504 @ 6 - 4/0

4/0 - 500

2@ 4/0 - 5004 @ 6 - 4/0

PHM5-4/0-500B

*Meets ANSI C119.1 and C119.4 Requirement 600 Volt Rated

6 - 4/0

2

2

2

2

3

4

4

4

5

5

5

5

5

5

6

6

12

12

10

4

6

9

9

12

6

6

9

9

6

6

6

5

4

Ordering Information

8

MTRS Series

Mechanical Tension Repair Splice

Repair splice for slack

and tensioned cables

FEATURES

• Large range taking ability

• Full tension mechanical connection

• Double shear head bolts

• Bolts never come in contact with

conductor

• Easy installation – use tools already

available on Line Trucks

• No cable brush required

• No dissimilar metals so no corro-

sion

• Cable is distended in a wave pattern

which greatly increases friction

• Rated for 10,000 lb

MTRS Series

APPLICATIONS

Ordering Information

Part #Conductor

Range

Conductor Area Range

(kcmils)

ConductorType

Nb of Bolts per slide

Bolt Head size (in)

Approx Torque to Shear theBolt (in-lbs)

First Second

Length (in)

10 3/8

13 1/2

15 7/8

17 3/4

*Meets ANSI C119.4 Requirement

Note: Install with a 3/4” impact socket

MTRS-04 and MTRS-02

480

520

780

780

620

700

1100

1100

3/4

3/4

3/4

3/4

4

5

5

5

aac/aaac/acSr/acar

aac/aaac/acSr/acar

aac/aaac/acSr/acar

aac/aaac/acSr/acar

41.7 - 106

106 - 212

168 - 370

330 - 570

#4 - 1/0

1/0 - 4/0

3/0 - 370 kcmil

330 - 570 kcmil

MTRS-01

MTRS-02

MTRS-03

MTRS-04

www.sicameusa.com

Sicame CorporationTelephone: (630) 238-6680

Fax: (630) 238-6682

Postal address:Sicame Corporation808 North Central Avenue - Unit FWood Dale, IL 60191

General Information:[email protected]

Sales & Customer Support:[email protected]

Sending Purchase Orders:[email protected]

V1