Printing:ELLIS RESIDENCE
Building Information
Front View & Floor Plan
Orientation of Views
Locations
South-East Side South-West Side Architects: Coates Design
General Contractor: Smallwood Design
and Construction
Mechanical Engineer: Sound
Mechanical
Project Area: 2,560 sqf
Project Year: 2010
Bainbridge Island, Washington, USA
Hui Ling Chang
Printing:
Hui Ling Chang
Sun Chart
Direct Normal Radiation
Monthly Diurnal Averages
Monthly Diurnal Averages
Legend-hourly averages
Wind Wheel
Legend
WEATHER CONDITIONS
Printing:
Building Performance Evaluations
Modeling energy performance of selected building in different software
Energy Pro
HEED
Modeling Tools
HEED EnergyPro Energy Plus Design Builder IESVE EQUEST
DesignBuilder
IESVE
IES
eQUEST
SIMULATION TOOLSHui Ling Chang
Printing:
Design Summary Chart
HEED Energy Pro eQuest Design Builder IES-VE
Heating sys Best furnace 0.97 AFUE Best furnace 0.97 AFUE
Cooling sys Split System, 19.5 SEER Split DX, 19.5 SEERPackaged Terminal
Heat PumpSplit System Split System
DHWHeat Pump
Energy factor=2Electric Heat Pump Electricity Equipment Electric Heat Pump N/A
Wall
Stucco, 9" insulated foam
forms concrete filled and
plaster board interior
Masonry, R-21 Wall8 in. CMU with wood
external finish
Wall 116
(Mass Wall)
8 In. Heavy Weight
Concrete Block
InsulationSuperer insulation to 2
times curren codeInsulation
2 in. polyisocyanurate R-
12
R-28 Insulation
Board4 In. Insulation
Roof Flat and sloped roof R-38 RoofAttic 8 in. ConcreteFlat roof - 19mm
asphalt on 75mm screed
4 In. Wood
with 12 In. Insulation(
ASHRF 212, U=0.0204)
FloorSlab on grade exposed or
tiledConcrete
vert ext bd, R-20,
4ft deep
IECC-2000 Ground floor
slab
Heavyweight
Concrete Slab Internal
Ceiling
(CNCR0001, U=0.3468)
Infiltraion 1.5 SLA 0.06ACH 0.001 CFM/SF 0.06ACH N/A
GlazingClear Triple Pane 1/8" in
wood frame
Triple Pan,
U=0.260 SHGC=.0200
Triple Low-E(e5=o.1)
Clear 1/8", 1/4" Air
Trp LoE (e5=.1) Clr
3mm/13mm Arg
Low-E Triple Glazing
SHGC=0.1576, U=0.2563)
HEATING LOAD EUI COOLING LOAD EUI HOT WATER EUI TOTAL EUI/2
EU
I (K
BT
U/S
F/Y
)
HEED EnergyPro eQuest Design Builder IES-VE WareEUI of various Best Design Buildings
DESIGN CONDITIONSHui Ling Chang
Printing:
Description
The heating and cooling change in different ways in different software by replacing the furnace with heat pump.
Monthly Energy Consumption by End Use
Energy Performance
EVALUATION IN EQUESTHui Ling Chang
Printing:
Description
For larger area of window with furnace and heat pump systems
When increasing the area of windows, the design with heat pump decreases more energy because it not only decreases heating energy but also reduces hot water consumption
As built-furnace Best Desgin1-heat pump
Best Desgin1-
with overhangs for all
windows
As built-furnace-bigger
windows
Best Desgin1-
with overhangs for bigger
windows
Eergy Type Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas
Unit kBtu/sf yr kBtu/sf yr kBtu/sf yr kBtu/sf yr kBtu/sf yr kBtu/sf yr kBtu/sf yr kBtu/sf yr kBtu/sf yr kBtu/sf yr
Space Cool 0.00 0.00 2.73 0.00 1.30 0.00 0.00 0.00 2.50 0.00
Space Heat 0.00 13.49 0.85 0.00 1.26 0.00 0.00 15.19 1.00 0.00
HP Supp. 0.00 0.00 0.81 0.00 1.00 0.00 0.00 0.00 0.91 0.00
Hot Water 0.00 11.05 0.00 11.06 0.00 11.07 0.00 11.05 8.10 0.00
Vent. Fans 3.18 0.00 3.54 0.00 3.01 0.00 3.03 0.00 1.70 0.00
Ext. Usage 1.57 0.00 1.57 0.00 1.57 0.00 1.57 0.00 1.57 0.00
Misc. Equip. 5.76 0.00 5.76 0.00 5.76 0.00 5.76 0.00 5.76 0.00
Area Lights 2.27 0.00 2.27 0.00 2.27 0.00 2.27 0.00 2.27 0.00
Sub Total 12.78 24.54 17.53 11.06 16.18 11.07 12.63 26.23 23.80 0.00
Total 37.30 28.60 27.25 38.80 23.70
Hui Ling Chang
Printing:
Description
The target building was modeled in Energy Plus and the space is divided into five zones
3D Model
Zoning
Chart of System Energy
Heating and Cooling Plants Summaries
Level 2 Level 1
EVALUATION IN IESHui Ling Chang
Printing:
Generally, the solar gain does not positively affect external heat conduction gain
Solar Gain & External Conduction
Orientation & Sensible Load
Total Energy
System to Sub-system Energy
Room
No.Orientation Floor Area
Heating
Plant
Sensible
Load in
Jan.
Btu/ft2
External
Conductio
n Gain in
Jan.
kBtu/ft2
1 Overall 1705 0.7 1.99
3 North-west 181 0.94 1.19
4 North-east 171 0.95 1.22
5 South-west 190 0.85 1.06
6 South-east 179 0.87 0.92
The north-east rom has highest heating plant sensible load, but the south-west room has the lowest external conduction gain
Total system energy is compose of 33% electricity that supports auxiliary vent and DHW and 67% gas supports boiler
Hui Ling Chang
Printing:
Description
Evaluate the relation between orientation and solar radiation distribution
Information of Target Room
Room Size: 15’x 10’x 10’ ( L x W x H ) Window of Wall Ratio: 20% Window Size: 5’x 6’ Location: Los Angeles
North
Window
South
Window
West
Window East
Window
EVALUATION OF DAYLIGHTINGHui Ling Chang