5
 Author: Teoh Su-Fern, Elyse Kymberly (007950) Title: General Aspects  Energy Recovery & Utility Balances Supervisor: Dr. Lee Lai Yee Group Number: Group 5 Page 1 Energy Recovery & Utility Balances Section A: Energy Recovery Heat integration is done in order to save operating costs on utilities such as cooling water, hot oil, superheated steam, etc. After conducting pinch analysis, it is found that a threshold problem is present with a minimum heating utility of 178.51 kW. The total energy recovered is 2922.25 kW. The pinch occurs at 40 o C (cold pinch) and 50 o C (hot pinch). The heat cascade, hot and cold composite curves, grand composite curve and heat exchanger grid diagram are shown in the figures below: Figure A1: Heat Cascade Figure A2: Hot and Cold Composite Curves

Energy Recovery & Utility Balances

Embed Size (px)

Citation preview

Page 1: Energy Recovery & Utility Balances

8/11/2019 Energy Recovery & Utility Balances

http://slidepdf.com/reader/full/energy-recovery-utility-balances 1/4

 Author: Teoh Su-Fern, Elyse Kymberly (007950)

Title: General Aspects – Energy Recovery & Utility Balances

Supervisor: Dr. Lee Lai Yee

Group Number: Group 5 Page 1 

Energy Recovery & Utility Balances

Section A: Energy RecoveryHeat integration is done in order to save operating costs on utilities such as cooling water, hot oil, superheated

steam, etc. After conducting pinch analysis, it is found that a threshold problem is present with a minimum heating

utility of 178.51 kW. The total energy recovered is 2922.25 kW. The pinch occurs at 40oC (cold pinch) and 50

oC (hot

pinch).

The heat cascade, hot and cold composite curves, grand composite curve and heat exchanger grid diagram are

shown in the figures below:

Figure A1: Heat Cascade

Figure A2: Hot and Cold Composite Curves

Page 2: Energy Recovery & Utility Balances

8/11/2019 Energy Recovery & Utility Balances

http://slidepdf.com/reader/full/energy-recovery-utility-balances 2/4

 Author: Teoh Su-Fern, Elyse Kymberly (007950)

Title: General Aspects – Energy Recovery & Utility Balances

Supervisor: Dr. Lee Lai Yee

Group Number: Group 5 Page 2 

Figure A3: Grand Composite Curve

Figure A4: Heat Exchanger Grid Network

The updated process flow diagram with the heat exchanger network is attached as Figure A5.

0

50

100

150

200

250

300

350

400

450

0 500 1000 1500 2000

   S    h   i    f   t   e    d   T   e   m   p   e   r   a   t   u   r   e   s    (   o   C    )

Enthalpy (kW)

Grand Composite Curve

Min. Heating Utility = 178.51 kW

Page 3: Energy Recovery & Utility Balances

8/11/2019 Energy Recovery & Utility Balances

http://slidepdf.com/reader/full/energy-recovery-utility-balances 3/4

 Author: Teoh Su-Fern, Elyse Kymberly (007950)

Title: General Aspects – Energy Recovery & Utility Balances

Supervisor: Dr. Lee Lai Yee

Group Number: Group 5 Page 3 

Section B: Utility Balances

1. Heat Exchangers

2. Reactor Energy Balance

Heating Duty Required = 2887.28 kW

Heat Transfer Fluid Requirement = 315.94 kg/s= 1137384.0 kg/h

Note: Detailed calculations will be shown in the appendix (section reactor design)

Heat

Exchanger

Energy

(kW)

Utility

Shell Side Tube Side

Type Flowrate

(kg/h)

Supply

Temperature

(oC)

Target

Temperature

(oC)

Type Flowrate

(kg/h)

Supply

Temperature

(oC)

Target

Temperature

(oC)

HE-01 489.43 ProcessFluid 16105.8 409.0 359.6 ProcessFluid 16105.8 66.0 108.0

HE-02 4129.63 Process

Fluid

16105.8 108.0 128.0 Heat

Transfer

Fluid

1090131.9 386 380.3

HE-03 554.06 Process

Fluid

8052.9 359.6 247.7 Process

Fluid

16105.8 128.0 191.3

HE-04 554.06 Process

Fluid

8052.9 359.6 247.7 Process

Fluid

16105.8 191.3 254.6

HE-05 178.51 Heat

Transfer

Fluid

47252.1 386.0 380.3 Process

Fluid

16105.8 254.6 275.0

HE-06 1324.70 ProcessFluid 16105.8 247.7 114.0 ProcessFluid 29032.7 40.0 90.0

HE-07 3815.30 Process

Fluid

16105.8 114.0 40.0 Chilled

Water

327028.4 10.0 20.0

HE-08 2700.00 Process

Fluid

22803.1 125.0 130.0 High

Pressure

Steam

120000.0 300.0 259.0

HE-09 238.00 Process

Fluid

6262.0 46.0 37.0 Cooling

Water

51300.0 30 34

HE-10 13139.00 Process

Fluid

68760.0 130.0 145.0 Medium

Pressure

Steam 

817200.0 190.0 170.0

HE-11 13111.00 Process

Fluid

55440.0 110.0 90.0 Cooling

Water

1129176.0 30.0 50.0

HE-12 18600.00 Process

Fluid

1472.1 128.7 128.7 Low

Pressure

Steam 

56800.8 147.7 128.7

HE-13 5004.10 Process

Fluid

6852.3 112.9 96.0 Chilled

Water

158749.2 7.0 34.6

Page 4: Energy Recovery & Utility Balances

8/11/2019 Energy Recovery & Utility Balances

http://slidepdf.com/reader/full/energy-recovery-utility-balances 4/4

 Author: Teoh Su-Fern, Elyse Kymberly (007950)

Title: General Aspects – Energy Recovery & Utility Balances

Supervisor: Dr. Lee Lai Yee

Group Number: Group 5 Page 4 

3. Pumps & Compressors

4. Acetaldehyde Storage Tank

Cooling duty required = 56.9 kW

Chilled water required = 9754.3 kg/h

Pump Power (W)

P-001 537.10

P-002 2470.66

P-003 606.59

P-004 991.52

P-005 1241.38

P-006 421.52

P-007 265.95

P-008 769.59

P-009 183.63

P-010 3746.95

P-011 479.86

P-012 652.82

P-013 2523.82

P-014 2920.96

P-015 63.88

Compressor Power (kW)

COMP-01 1426.21