5
Datasheet for Single Circuit Without Pilot Terminal Types Energy Regulator Simmerstats MANUFACTURER MADDOCKS MODEL LIVE TO NEUTRAL TO LOAD 1 TO DIAMOND H 20ER1 LINE NEUTRAL LOAD DIAMOND H 30ER1HT LINE NEUTRAL LOAD A DIAMOND H 30ER1TF LINE NEUTRAL LOAD A DIAMOND H 14-ER-05 30ER14MHT P1 4A 2 DIAMOND H 14-ER-08 40ER101C1 P1 4A 2 SATCHWELL TYJ01B 1 RL G SUNVIC TYJ01B LINE NEUTRAL LOAD SUNVIC use 14-ER-01 TYJ6202 LINE NEUTRAL LOAD SUNVIC use 14-ER-01 TYJ6219 LINE NEUTRAL LOAD TURNRIGHT 19-1103 4 2 1 TURNRIGHT 20-1103 4 2 1 TURNRIGHT RC1103 L OR LIVE N OR NEUTRAL LOAD A TURNRIGHT RC2103 L OR LIVE N OR NEUTRAL LOAD A EVERYTHING FOR COMMERCIAL & DOMESTIC APPLIANCES

Energy Regulator Simmerstats

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Energy Regulator Simmerstats

Datasheet for Single Circuit Without Pilot Terminal Types

Energy Regulator Simmerstats

MANUFACTURER MADDOCKS MODEL LIVE TO NEUTRAL TO LOAD 1 TO

DIAMOND H 20ER1 LINE NEUTRAL LOAD

DIAMOND H 30ER1HT LINE NEUTRAL LOAD A

DIAMOND H 30ER1TF LINE NEUTRAL LOAD A

DIAMOND H 14-ER-05 30ER14MHT P1 4A 2

DIAMOND H 14-ER-08 40ER101C1 P1 4A 2

SATCHWELL TYJ01B 1 RL G

SUNVIC TYJ01B LINE NEUTRAL LOAD

SUNVIC use 14-ER-01 TYJ6202 LINE NEUTRAL LOAD

SUNVIC use 14-ER-01 TYJ6219 LINE NEUTRAL LOAD

TURNRIGHT 19-1103 4 2 1

TURNRIGHT 20-1103 4 2 1

TURNRIGHT RC1103 L OR LIVE N OR NEUTRAL LOAD A

TURNRIGHT RC2103 L OR LIVE N OR NEUTRAL LOAD A

EVERYTHING FOR COMMERCIAL & DOMESTIC APPLIANCES

Page 2: Energy Regulator Simmerstats

EVERYTHING FOR COMMERCIAL & DOMESTIC APPLIANCES

MANUFACTURER MADDOCKS MODEL LIVE TO NEUTRAL TO LOAD 1 TO PILOT ADDTIONAL WIRING INFORMATION

DIAMOND H 21ER2 LINE NEUTRAL LOAD A PILOT

DIAMOND H use 14-ER-01 21ER1TF LINE NEUTRAL LOAD A PILOT

DIAMOND H use 14-ER-01 31ER1HT LINE OR P1 NEUTRAL OR 2 LOAD A OR 2 PILOT OR S

DIAMOND H 14-ER-08 31ER1MHT P1 P2 2 S

DIAMOND H use 14-ER-01 31ER5HT P1 P2 2 S

DIAMOND H 14-ER-20 31ER7HT P1 P2 2 S

DIAMOND H 31ER9KHT P1 P2 2 S

DIAMOND H use 14-ER-08 40ER101 P1 P2 2 S

DIAMOND H 101-IN-35974 41ER101C1 P1 4A 2 4 LINK P1 TO 4

DIAMOND H use 101-IN-35974 41ER101C1P P1 4A 2 4

DIAMOND H 14-BL-139 48ER101C1 P1 4 2 S2 LINK P1 TO S1, LOAD N TO 4, DOUBLE POLE SWITCHING

EGO 14-ER-05 50.57010.010 P1 4 2 S2 LINK P1 TO S1

EGO 50.57020.080 P1 4 2 S2 LINK P1 TO S1, PILOT N TO PILOT

EGO 14-ER-05 50.57020.030 P1 4 2 S2 LINK P1 TO S1, PILOT N TO PILOT

Datasheet for Single Circuit With Pilot Terminal Types

Energy Regulator Simmerstats

Page 3: Energy Regulator Simmerstats

EVERYTHING FOR COMMERCIAL & DOMESTIC APPLIANCES

MANUFACTURER MADDOCKS MODEL LIVE TO NEUTRAL TO LOAD 1 TO PILOT ADDTIONAL WIRING INFORMATION

EGO use 14-ER-05 50.57021.010 P1 4 2 PILOT OR S2

EGO 112-HY-05247 50.57071.010 P1 4 2 S2 LINK P1 TO S1

EGO 14-ER-29 50.56071.020 P1 4 2 PILOT LINK P1 TO S1

EGO 50.57071.130 P1 4 2 S2 LINK P1 TO S1

EGO 14-HY-01 50.57024.010 P1 4 2 S2 LINK P1 TO S1, PILOT N TO PILOT

INVENSYS 14-ER-34 MSA-V01 PHASE N1 LOAD S2

INVENSYS MSA-V01-CS PHASE N1 LOAD S2

INVENSYS 14-ER-28 MP-V01-SVC P1 P2 OR 4 2 S2

SATCHWELL use 14-ER-01 TYJ02B L RL OR NEUTRAL G OR LOAD P OR PILOT

SIEBE MSA312-SV PHASE N2 LOAD N1 TO N2 & S1 TO S2 SWITCHED CONTACTS

STRIX OG1004 P1 4A 2 4

STRIX OG1014 P1 4A 2 4

STRIX 14-ER-27 OG1015 P1 4 2 S2

STRIX use 14-ER-28 OG1206 P1 4 2 S2

STRIX OG2004 P1 4 2 S2 LOAD N TO P2, DOUBLE POLE SWITCHING

STRIX OG1215 P1 4 2 S2

SUNVIC TYJ01B LINE NEUTRAL LOAD P

SUNVIC use 14-ER-01 TYJ02B L RL 4 P

SUNVIC TYJ6201 LINE NEUTRAL LOAD PILOT

SUNVIC use 14-ER-01 TYJ6202 LINE NEUTRAL LOAD PILOT

SUNVIC use 14-ER-01 TYJ6303 LINE NEUTRAL LOAD PILOT

TURNRIGHT 19-1113 1 2 2 3

TURNRIGHT 20-1113 1 2 2 3

TURNRIGHT 14-ER-01 RC1113 L OR LIVE N OR NEUTRAL LOAD A P/L

Datasheet for Single Circuit With Pilot Terminal Types

Energy Regulator Simmerstats

Page 4: Energy Regulator Simmerstats

EVERYTHING FOR COMMERCIAL & DOMESTIC APPLIANCES

MANUFACTURER MADDOCKS MODEL LIVE TO NEUTRAL TO LOAD 1 TO LOAD 2 TO PILOT ADDTIONAL WIRING INFORMATION

DIAMOND H 23ER3 LINE OR P1 NEUTRAL OR P2 LOAD A OR 2 LOAD B OR 4 PILOT OR S

DIAMOND H 23ER14TF LINE1 NEUTRAL LOAD A OR 2 LOAD B OR 4 PILOT OR S

DIAMOND H 14-ER-03 27ER3 LINE NEUTRAL LOAD A LOAD B PILOT

DIAMOND H 14-ER-02 33ER3HT LINE OR P1 NEUTRAL OR P2 LOAD A OR 2 LOAD B OR 4 PILOT OR S

DIAMOND H 33ER3TF LINE OR P1 NEUTRAL OR P2 LOAD A OR 2 LOAD B OR 4 PILOT OR S

DIAMOND H 104-ST-05838 33ER6HT P1 P2 2 4 S

DIAMOND H 33ER18HT P1 P2 2 4 S C/W SWITCH ASSY FOR TOP OVEN CONTROL

DIAMOND H 33ER23MHT P1 P2 2 4 S

DIAMOND H 14-ER-09 33ERX22M LINE NEUTRAL LOAD A LOAD B PILOT

DIAMOND H 14-ER-03 37ER2 P1 P2 2 4 S

DIAMOND H 14-ER-07 43ER101C1P P1 4 2 P2 S2 LINK P1 TO S1

DIAMOND H 14-BL-139 48ER101C1P P1 4 2 P2 S2 LINK P1 TO S1

Datasheet for Dual Circuit With Pilot Terminal Types

Energy Regulator Simmerstats

Page 5: Energy Regulator Simmerstats

EVERYTHING FOR COMMERCIAL & DOMESTIC APPLIANCES

MANUFACTURER MADDOCKS MODEL LIVE TO NEUTRAL TO LOAD 1 TO LOAD 2 TO PILOT ADDTIONAL WIRING INFORMATION

EGO 14-EL-09 50.55023.010 P1 P2&4* 2 2A S2 *CONTACTS LINKED. LINK P1 TO S1

EGO 14-ER-12 50.55073.010 P1 P2&4* 2 2A S2 *CONTACTS LINKED. LINK P1 TO S1

EGO 50.55023.071 P1 P2&4* 2 2A S2 *CONTACTS LINKED. LINK P1 TO S1

EGO 14-ER-09 50.55073.071 P1 P2&4* 2 2A S2 *CONTACTS LINKED. LINK P1 TO S1

EGO 50.55203.071 P1 P2&4* 2 2A S2 *CONTACTS LINKED. LINK P1 TO S1

STRIX OG2004 P1 4 2 P2 S2

SUNVIC TYJ07B LINE NEUTRAL LOAD A LOAD B PILOT

SUNVIC TYJ08B LINE NEUTRAL LOAD A LOAD B PILOT

SUNVIC 14-ER-03 TYJ6802 LINE NEUTRAL LOAD A LOAD B PILOT

SUNVIC TYJ6805 LINE NEUTRAL LOAD 1 LOAD 2 PILOT

TURNRIGHT 19-1203 4 2 1 3

TURNRIGHT 20-1203 4 2 1 3

TURNRIGHT RC1203 LIVE NEUTRAL LOAD A LOAD B R/L

TURNRIGHT 14-ER-02 RC1213 L OR LIVE N OR NEUTRAL LOAD A LOAD B R/L

TURNRIGHT 19-1213 1 2 4 3 5

TURNRIGHT 20-1213 1 2 4 3 5

Datasheet for Dual Circuit With Pilot Terminal Types

Energy Regulator Simmerstats