3

ENERGY SAVING LES for - atandra · 2019. 12. 31. · KRYKARD LES comes with a Load Manager to display kW & kWh among other electrical parameters, to know the energy consumption patterns

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ENERGY SAVING LES for - atandra · 2019. 12. 31. · KRYKARD LES comes with a Load Manager to display kW & kWh among other electrical parameters, to know the energy consumption patterns
Page 2: ENERGY SAVING LES for - atandra · 2019. 12. 31. · KRYKARD LES comes with a Load Manager to display kW & kWh among other electrical parameters, to know the energy consumption patterns

s

a cost-effective way to conserve energy of lighting loadswithout heavy investments or cumbersome changes in light ttings.

With increasing energy tariffs, the energy costs even on account of lighting loads is becoming signicant. Numerous methodsof saving lighting energy costs without compromising on lighting needs are being considered. Many a times these includeheavy investments or expensive and cumbersome changes.

LES offers a simpler solution in conserving Energy on all types of lighting including old ttings with copper chokes, new ttingswith electronic chokes, tube-lights, CFLs, etc

LES for...

Old Lighting installations with copper chokes

Lighting with a combination of ElectronicBallasts and Copper Chokes

Lighting with Electronic Ballasts / T5 tube lights

savings of up to

savings of up to

25%

20%

savings of up to

15%

ENERGY SAVING

PROTECTION

QUALITY OF LIGHTING

Ÿ Saves up to 25% energyŸ Works effectively on all types of lightingŸ Improves PF reducing cable lossesŸ Reduces kVA Demand

Ÿ Increases lamp life and reduces replacement costs

Ÿ Reduces THD on current xtures that generate harmonics

Ÿ Ensures consistency of lighting which enables better productivity

Also works on Sodium Vapour Lamps, Mercury Vapour Lamps and Metal Halide Lamps

LES is a device that saves energy by maintaining the power delivered to the lighting loads at an optimum voltage, withoutvisibly comprising on the quality of lighting (Lumen output) or comfort.

All types of lamps (except incandescent bulbs) have a non-linear curve for power consumption and lumen delivered.Depending on the type of lamp, about 20% lower wattage results in 5 to 10% lumen drop, which is not easily perceived by the naked eye.

Appropriate power supply to lighting loads also results in improved power factor and reduced harmonics.

KRYKARD LES comes with a Load Manager to display kW & kWh among other electrical parameters, to know the energy consumption patterns with or without LES, thereby instantaneously quantifying savings in energy.

Ofces, Commercial complexes, Hospitals, Educational Institutes, Research laboratories, Residential complexes, Industries,Campus Lighting

Specificaa�on Wide Range Model Regular RangeAir-cooled Model

Regular RangeAir-cooled Model

R Phase

Input

Isolator MCBOpera�ng Mode

Manual Bypass

LES Mode

Y Phase

LES Bypass

B Phase

LES UV/OV

ENERGY CONSERVER

Menu ˃ ˃

YOU ARESAVING ENERGY

LES is Opera�ng o saveenergy & protect your ligh�ng ystem

PROTECTIONCONTINUESEven when input voltage isabnormal, LES con�nuesto protect and preventfailures in your ligh�ngsystem

YOU WOULD KNOW WHEN THIS GLOWS

This glows either due tomanual bypass ac�on or a fault condi�on

MINI CIRCUITBREAKER(MCB)

For short-circuitprotec�on t input

SAFETY FEATURE

Used during maintenance

TESTING & CHECKINGManual bypass eitherfor tes�ng L S or for checking energy savings

INTELLIGENT

with RTC

and 5 se�able �me zones, each with independent voltage se�ngs

AVAILABILITYOF POWERPhase indicators to tell you availability of powerin each of the phases

SEEING IS BELIEVING

kW/kVA/PF and Energydata for instantaneousassessment of savings

Load ManagerSMART CURRENT SENSOR

Senses when load increases to adjust voltage to ensure sufficient voltage during lamp start-up

CONTROLLER

LES Controller

Parameters Measured

Time Zones

Page 3: ENERGY SAVING LES for - atandra · 2019. 12. 31. · KRYKARD LES comes with a Load Manager to display kW & kWh among other electrical parameters, to know the energy consumption patterns

Revision: May 2017. Specifica�ons are subject to change without prior no�ce.KRYKARD is a registered trademark owned by Atandra Energy Pvt. Ltd.

Atandra Energy Private Limited

No. 5, Kumaran Street, Pazhavanthangal, Chennai - 600 114Tel: +91 44 4278 0700 | 4278 0600

www.atandra.in | [email protected]

Kochi | Kolkata | Madurai | Mumbai | Nagpur | New Delhi | Pune | Tiruppur | Vishakapatnam

Ahmedabad | Bengaluru | Bhopal | Chennai | Coimbatore | Guntur | Hosur | Hubli | Hyderabad