Energy Usage Monitoring and Management Solutions
Solutions on new generation IP networks, helped companies to have a solid step
on increasing energy consumptions and enviroment.
Corporate Buildings Energy Consumptions – Big Picture
HVAC $209b58%
LIGHTING 11%OTHER
TOTAL = $360b
$40b
Sources
. EnergyStar “Fast Facts on Energy Use”
. Gartner “ IT hardware Energy Consumption, Worldwide”
IT $90b25%
IT = $90b
PC’s, Laptops,Monitors 31,5%
Network 31,7%
Servers 16,2%
Printers 14,5%
Mobile Phones 6,1%
Institution buildings’ total cost of annual energy consumption is $360b. $30b of this cost is spent to network infrastructures which includes IP phones, Access points andswitches.
Examples to Annual Energy Consumption Cost of Network Devices
23,97 62,56 511,52
IP telefon 796X Switch 3560AP 3600
Annual EnergyConsumption Cost*
Annual EnergyConsumption Cost*
Annual EnergyConsumption Cost*
796X 1007
794X 9255
69XX 4018
5003560
3003600APs
4002960
IP Phones
Switches
16.809,33 30,22 %
89.328,18 30,99 %
24.103,42 32,08 %
132.451,20
13.223,57
48,21 %
42.774,48 56,63 %
29,54 %
Device Model# ofDevice Total Savings **
Total SavingPercentage
* Cost of 1 Kwatt - 0,42 ** Holidays in 1 year - 110 , Work days in 1 year - 255
Chosen examples of the network devices used by our clients show the big decrease on annual energy consumption cost.
If we take a look at a institution based example, we take the headquarters and other offices total device numbers in count. If we take these three device groups as an example, we see more than 40% decrease on energy consumption and with this decrease the company will save more than $150.000 annually.
Step by Step Solution Dissemination
CLOUD SYSTEMSDATA CENTER
NETWORK DEVICESFACILITY
Monitoring and managing energy consumption of lighting and climatization will also be possible with entegration ofbuilding management systems.
It can save more than 40% of energy consumption on network devices such as IP phones, swithces and APs with the energy usage monitoring and management solution.
Other CT infrastructure components energy consumptions can be monitored and determined policies can be applied to PCs and printers through one management platform.
It is stretegically important for the compannies to utilize energy management solutions in planning and operating Data Centers. Besides PDU and cabinets, you can also take reports on the power consumption of servers ,CPU and DC.
Policy Setting According to Speci�c Customer Needs
Event Based Location BasedTime Based
IP Phones : IP Phones : IP Phones :
Outside the working hours IP phones are put to deep sleep mode. For different profiled employees, different time planning can be done.
When building management systems are entegrated, apart from the time planning, IP phones are put to deep sleep mode when workers leave the office.
When building management systems are entegrated, IP phones are put to deep sleep mode by the use of passes and smart phone location information.
AnkaraAnkara Ticaret Merkezi, ABlok Kat: 15Kızılırmak Mahallesi, 1450. SokakÇankaya 06520 Ankara
Tel. : +90 312 468 23 73Fax : +90 312 468 23 80
İstanbulAkın Plaza, Kat: 8Darülaceze Caddesi, No:3Şişli 34382 İstanbul
Tel. : +90 (212) 267 55 55Fax : +90 (212) 267 49 61
İzmir99 Basamak İş Merkezi, D:202Şehit Fethi Bey Caddesi No: 43 PasaportKonak 35210 İzmir
Tel. : +90 (232) 489 59 44Fax : +90 (232) 489 59 44
Bilgi ve sorularınız için [email protected] adresine mail atın, size dönelim.