29.11.2017 Enervent Neo Maintenance, Repair and Recycling manual

Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

29.11.2017

Enervent Neo

Maintenance, Repair and Recycling manual

Page 2: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

2

Copyright © Enervent 2017.

Unauthorised copying and distribution is forbidden.

Page 3: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

3Maintenance , Repair and Recycling manual

CONTENTS

READ FIRST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

TYPE PLATE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Electrical safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

UNIT MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Opening the lower service hatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Taking the spare belt into use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Changing the heat exchanger motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Dismantling of lower part . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Cleaning the heat exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Changing the heat exchanger drive belt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Dismantling of upper part . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Maintenance of fans and heater element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Cleaning of fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

TAKING UNIT INTO USE AFTER SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Reassembling the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

APPENDICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

RECYCLING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Dimensional drawing, left handed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Dimensional drawing, right handed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

ELECTRICAL DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

External connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Internal connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Electrical heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

SPARE PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Page 4: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

4

READ FIRST

This instruction manual is intended for all people involved in maintenance and repairing of the Enervent ventilation units. Only professionally skilled persons may maintain and repair the equipment described in this manual, according to the instructions provided in this manual and to the local laws and regulations. Failure to comply with the instructions provided in this manual will result in cancellation of the warranty for the equipment and may result in harm to people or property.

The equipment described in this manual may not be used by persons (including children) with reduced physical, sensory or mental capacity or without sufficient experience or knowledge, unless a person responsible for their safety is supervising and advising in the use of the equipment.

Page 5: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

5Maintenance , Repair and Recycling manual

Should you need any technical support, refer to the type plate for the equipment type and serial number before contacting support.

Technical support: www.enervent.com/contact-information/

Webshop for supplies and spareparts: webshop.enervent.com

Service instructions and service requests: www.enervent.com/help-center/

TYPE PLATE

ilmanvaihtolaiteventilation unit

TYYPPI/TYPE:

W/ V/ HZ / A:

www.enervent.com

SRJ. NRO/SERIAL NO:

IP 20

Page 6: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

6

SAFETY

General Electrical safety

Always check that the equipment supply voltage is switched off before opening the service hatch.

Only an authorised electrician may perform any actions in the electrical box.

Follow the local regulations on electrical installations.

In case of malfunction, always find out the reason for the malfunction before starting the unit again.

Wait for two (2) minutes after switching off the power of the unit before commencing the maintenance. Although the power is switched off, the fans continue running and the heating element stays hot for a while.

Check that the unit is entirely isolated from the mains before conducting any voltage tests, insulation resistance measurements or other electrical work or measurements. Such work may damage the sensitive electrical devices.

Control devices used in the ventilation units may cause leakage current. It may affect the operation of the residual current devices.

All ventilation units with a control system must be equipped with an over-voltage arrester.

DANGER DANGER

DANGERWARNING

WARNING CAUTION

CAUTION

CAUTION

Page 7: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

7Maintenance , Repair and Recycling manual

UNIT MAINTENANCE

1

Taking the spare belt into use

Opening the lower service hatch

2

4

1

3

Always check that the equipment supply voltage is switched off before opening the service hatch.

DANGER

Page 8: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

8

Changing the heat exchanger motor

2

4

1

3

Page 9: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

9Maintenance , Repair and Recycling manual

Always check that the equipment supply voltage is switched off before opening the service hatch.

Dismantling of lower partBefore dismantling the lower part, open the lower service hatch, see page 7 picture 1.

3

1 2

4

5b5a

6a 6b

DANGER

Page 10: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

10

2

3 4

1

Check the cleanliness of the rotating heat exchanger visually when changing filters, and clean it if it looks dirty. Before cleaning the heat exchanger, see. "Dismantling of lower part" on page. 9. The cleaning is to be performed by an authorized service provider.

Cleaning the heat exchanger

Do not submerge the heat exchanger in water.The electric motor inside the heat exchanger must not get wet.

The use of a pressure washer is strictly forbidden.

WARNING WARNING

Page 11: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

11Maintenance , Repair and Recycling manual

Changing the heat exchanger drive belt

5

3

1 2

4

Before changing the belt, see. "Dismantling of lower part" on page. 9.

7

6

8

Page 12: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

12

109

11 12

13 14

Page 13: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

13Maintenance , Repair and Recycling manual

Dismantling of upper part

5 6

Always check that the equipment supply voltage is switched off before opening the service hatch.

DANGER

Only an authorized service provider may dismantle the unit

1

3 4

2

Å power cord

7

Å external sensors

Page 14: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

14

Maintenance of fans and heater element

Look first. "Dismantling of lower part" on page. 9..

1

2a 2b

3 4

Page 15: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

15Maintenance , Repair and Recycling manual

Supply air fan

1

1

3

2

2

Cleaning of fans

4

65

Page 16: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

16

43

7

5

Extract air fan

1 2

Page 17: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

17Maintenance , Repair and Recycling manual

TAKING UNIT INTO USE AFTER SERVICE

2

3a 3b

4

Reassembling the unit

1

5

7

Å power cord

6

Å external sensors

silicone

Page 18: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

18

11 12

13 14

+2 mm 0 mm

10b10a

8 9

push all the way in 20 mm

22 mm 5 mm at a time

Page 19: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

19Maintenance , Repair and Recycling manual

18 19

0 mm0 mm

15

16

17b17a

Page 20: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

20

24

2322

20 21

Page 21: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

21Maintenance , Repair and Recycling manual

Page 22: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

22

Troubleshooting

APPENDICES

Alarm Description Alarmlimit Symptoms Possible cause Action Notes

FILS Service reminder.

4 or 6

months

It is time for regular maintenance. Replace the filters.

Inspect the ventilation unit.

Clean as necessary.

See if there are any damages visible.

Acknowledge by pressing any button for 5 seconds.

Err Sensor malfunction.

The sensor is in short circuit or there is an interruption in the circuit.

Check the connections and cables of the sensors.

- - - - Downloading. The eWind panel downloads data from the motherboard.

Normal during start-up. In other situations, check the eWind connection cable.

oFFE Stop mode. Ventilation off. External control system has switched the ventilation unit to stop mode.

AL1 Water heat-ing coil is in danger of freezing.

+8 °C Cold supply air. The water coil is frozen/about to freeze:

• The circulation pump has stopped.

• The heat exchanger does not rotate.

• The control valve actuator of the water coil is faulty.

• The extract fan has stopped.

Restart the pump. Replace the motor or the belt. Replace the actuator.

Find out the reason/replace the fan.

The unit will not start until the alarm mode is cleared and the alarm reset by pressing a button in the operation panel.

AL2 The supply air is cold after the rotating heat exchanger.

+5 °C Cold supply air. The heat exchanger does not rotate:

• The drive belt is damaged.

• The drive belt skids.

• The heat exchanger motor is damaged.

Replace the drive belt.

Clean or replace the belt or the heat exchanger.

Replace the heat exchanger motor.

The ventilation unit switches to malfunction mode, in which the fans operate with mini-mum power.

The alarm is auto-matically reset when the fault is cleared.

AL3 Cold supply air.

+10 °C Cold supply air. The extract fan has stopped. Replace the fan.The extract filter is clogged. Replace the filter.

The ventilation is adjusted incor-rectly/not adjusted at all.

Adjust the ventilation as per the ventilation system plan with appropriate measure-ment tools.

The heat insulation of the ducts is insufficient.

Check the insulation thick-ness of the supply and extract air ducts and add insulation as necessary.

The fan speed of the ventilation unit is incorrect.

Always use a fan speed specified by the ventila-tion unit designer (also in winter).

AL4 Supply fan malfunction.

No ventilation. The supply fan has stopped. Repair or replace the supply fan.

The unit will not start until the alarm mode is cleared and the alarm is reset by pressing a button in the operation panel.

AL5 Extract fan malfunction.

No ventilation The extract fan has stopped. Repair or replace the extract fan.

Page 23: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

23Maintenance , Repair and Recycling manual

RECYCLING INSTRUCTIONS

Check the recycling instructions regarding the end-of-life of the unit on the webpage www.enervent.com.

Alarm Description Alarmlimit Symptoms Possible cause Action Notes

AL6 Cold extract air.

+10 °C Cold supply air. Low indoor temperature. Raise the indoor temperature.

Acknowledge by pressing any button for 5 seconds.

Insufficient heat insulation of the extract air duct.

Check the insulation of the ducts and add insulation as necessary.

The ventilation unit’s service hatch is open.

Close the service hatch

Temperature sensor TE30 is faulty. Repair or replace the sensor.

AL7 Hot supply air.

Fire hazard.

+55 °C Hot supply air. Fire hazard. Check if there are any heat sources.

The device will not start until the alarm mode is cleared and the ventilation unit started again.

There is a malfunction in the electric after-heating coil.

Repair or replace the electric after-heating coil.

There is a malfunction in the actuator of the water-based after-heating coil’s valve.

Repair or replace the valve’s actuator.

Temperature sensor TE10 is faulty. Repair or replace the tem-perature sensor.

AL8 Overheating of the electric after-heating or preheat coil.

Hot supply air. Electric preheat or after-heating coil does not work:

• Overheating protector has tripped.

• The supply fan has stopped.

• The supply air filter is clogged.

• The outside air grille is clogged.

• The heater controller board is damaged.

• The heater is damaged.

Find out the reason for overheating and reset the error message.

Find out the reason/replace the fan.

Replace the filter.

Clean the grille. Remove any mosquito net.

Replace the controller board.

Replace the heaterAL9 Hot extract

air.

Fire hazard.

+55 °C Hot extract air. Fire hazard.

Temperature sensor TE30 is faulty.

Check if there are any heat sources. Repair or replace the tem-perature sensor.

Page 24: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

24

Dimensional drawingsDimensional drawing, left handed

Page 25: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

25Maintenance , Repair and Recycling manual

Dimensional drawing, right handed

Page 26: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

26

Electrical diagrams

External connectionsW

IRE

COLO

URS

BK

BLAC

KBN

BR

OW

NRD

RE

DO

G

ORA

NG

EYE

YE

LLO

WG

N

GRE

ENBU

BL

UE

GY

GRE

YW

H

WH

ITE

Page 27: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

27Maintenance , Repair and Recycling manual

Nam

eEx

plan

atio

nM

arki

ng o

n ci

rcui

t boa

rdFP

/EX

FIRE

PLAC

E/EX

TRAC

TOR

HO

OD

MO

DE

DI6

AWAY

AWAY

MO

DE

DI5

BOO

STM

ANU

AL B

OO

STD

I4ES

TOP

EXTE

RNAL

STO

PD

I1TE

45RE

TURN

WAT

ER T

EMPE

RATU

RE S

ENSO

R eW

ind

W U

NIT

STE

45TE

46RE

TURN

WAT

ER T

EMPE

RATU

RE S

ENSO

R eW

ind

CG U

NIT

STE

45TE

02PR

EHEA

TED

OU

TSID

E AI

R TE

MPE

RATU

RE, E

XTER

NAL

PRE

HEA

TER

TE02

TE20

RECI

RCU

LATI

ON

AIR

TEM

PERA

TURE

(KO

TILÄ

MPÖ

eW

ind)

TE02

TE10

SUPP

LY A

IR T

EMPE

RATU

RETE

10TE

01O

UTS

IDE

AIR

TEM

PERA

TURE

TE01

RH C

EXTE

RNAL

HU

MID

ITY

SEN

SOR

(RH

0-1

00%

) BY

DEF

AULT

IF P

ARAM

ETER

c27

IS A

CTI

VE, C

O² S

ENSO

R (2

00-2

000p

pm) (

ACCE

SSO

RY)

AI1

TL01

TL

50PR

EHEA

TER

VALV

E AC

TUAT

OR

-CH

G M

OD

ELS

CO

OLI

NG

VAL

VE A

CTU

ATO

R -C

G M

OD

ELS

AO6

TL45

HEA

TIN

G V

ALVE

AC

TUAT

OR

-W M

OD

ELS

AO5

DO

8A

LARM

A O

UTP

UT

BY D

EFAU

LT P

REH

EATE

R O

N/O

FF C

ON

TRO

L IN

-CH

G -A

GH

-ELE

CTR

ICA

L PR

EHEA

TER

MO

DEL

S CO

OLI

NG

ON

/OFF

CO

NTR

OL

IN -C

G M

OD

ELS

DO

8

DO

5O

UTS

IDE

AIR

AN

D E

XHAU

ST A

IR D

AM

PER

CON

TRO

L (A

CCES

SORY

)D

O5

DO

2H

EATI

NG

ON

/OFF

CO

NTR

OL

eWin

d W

MO

DEL

S

M

AX

500W

PU

MP

DO

2O

P1U

SERP

AN

EL 1

pcs.

INC

LUD

ED IN

DEL

IVER

Y, 1

0m C

ABL

E IN

CLU

DED

IF N

OT

MO

UN

TED

ON

UN

ITO

P1O

P2U

SERP

AN

EL (A

CCES

SORY

) 10

m C

ABL

E IN

CLU

DED

IN D

ELIV

ERY

OP2

Page 28: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

28

Internal connectionsW

IRE

COLO

URS

BK

BLAC

KBN

BR

OW

NRD

RE

DO

G

ORA

NG

EYE

YE

LLO

WG

N

GRE

ENBU

BL

UE

GY

GRE

YW

H

WH

ITE

Page 29: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

29Maintenance , Repair and Recycling manual

Nam

eEx

plan

atio

nM

arki

ng o

n ci

rcui

t boa

rdTE

45RE

TURN

WAT

ER S

ENSO

R eW

ind

W U

NIT

STE

45TE

46RE

TURN

WAT

ER S

ENSO

R eW

ind

CG U

NIT

STE

45TE

02PR

EHEA

TED

OU

TSID

E AI

R SE

NSO

RTE

02TE

20RE

TURN

AIR

TEM

PERA

TURE

(KO

TILÄ

MPÖ

eW

ind

UN

ITS)

TE02

TE32

EXH

AUST

AIR

TEM

PERA

TURE

SEN

SOR

TE32

TE10

SUPP

LY A

IR T

EMPE

RATU

RE S

ENSO

RTE

10TE

05AI

R TE

MPE

RATU

RE A

FTER

TH

E H

EAT

RECO

VERY

HEA

T EX

CHAN

GER

TE05

TE01

OU

TSID

E AI

R TE

MPE

RATU

RE S

ENSO

RTE

01RH

T30

EXTR

ACT

AIR

TEM

PERA

TURE

AN

D H

UM

IDIT

Y SE

NSO

R(RH

0-1

00%

)RH

T30

SF10

SUPP

LY A

IR FA

NAO

1,D

I11

EF30

EXTR

ACT

AIR

FAN

AO2,

DI1

2CF

20RE

TURN

AIR

FAN

(KO

TILÄ

MPÖ

UN

ITS

ON

LY)

AO6

M75

HEA

T RE

COVE

RY H

EAT

EXCH

ANG

ER M

OTO

RAO

4

Page 30: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

30

Electrical heaterW

IRE

COLO

URS

BK

BLAC

KBN

BR

OW

NRD

RE

DO

G

ORA

NG

EYE

YE

LLO

WG

N

GRE

ENBU

BL

UE

GY

GRE

YW

H

WH

ITE

Page 31: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

31Maintenance , Repair and Recycling manual

Product number Product nameK030160001 Neo Door 1M070100200 Sealing strip O-sealing with fastening D=7,5 464128300 2K930040220 Neo bulkhead door EPP 3M900500301 52389 GK plastic plug Fischer 4M480500015 Rubber grommet EV16 5-10 5M360500030 Sink strainer / kondensation drain P160010501A NEO 6M900100009 Nut DIN 934/8 ZN M20 7K100160002 Rotating heat exchanger, stepless drive Neo 8M140030016 Belt, PUW green,1440mm/6mm Neo 9K120160003 Rotor motor package, stepless DC Neo 10K140160001 Fan package, supply Neo 11K140160002 Fan package, extract Neo 12M680010040 Power cord 1,5m 3x1,5 including Molex and grommet 13M710910001 eWind motherboard 14M230110602 Humidity/temperature sensor Amphenol 600mm T9602-5-A-0.60-EV cable and connector 15M620200011 Tufvassons switch mode power supply PSLR 24 16M120200007 Control circuit board EM-240-M1 DC-motor 17M230120604 EDA temperature sensor 850mm 2-nap NTC 10K sensor 850 2-pol con 18M230120602 EDA temperature sensor 500mm 2-nap NTC 10K sensor 500 2-pol con 19K160163001 Electrical heater Neo eWind E 20M710600007 EDA electrical heater control circuit board Enerpoint 21K580040003 eWind control panel Neo Package includes operating panel and 350mm cable 22M210190142 Exchange filters F7/M5 (supply/extract) Unit size Neo 23M03P160010022 Wall mounting bracket 24M490300002 Switch, FA1CA22 Door switch 25

Spare parts list

Left handed

1

3

96

10

7

12

18

15

25

1116

19

13

22

23

20 21

142

8

4

17

24

5

Page 32: Enervent Neo · The use of a pressure washer is strictly forbidden. WARNING WARNING. ... EXTERNAL HUMIDITY SENSOR (RH 0-100%) BY DEFAULT IF PARAMETER c27 IS ACTIVE, CO² SENSOR (200-2000ppm)

Enervent OyKipinätie 1FIN-06150 Porvoo, FinlandTel. +358 207 528 800Fax. +358 207 528 [email protected]