17
ENGINEERING AND SURVEYING REPORT ON GEOTECHNICAL OBSERVATIONS Bicycle Apartments, LLC Proposed Residential Housing Development 118 North 50 th Avenue Yakima, Washington 98907 Yakima County Tax Parcel Id: 181321-41425 April 11, 2017 PLSA Project No. 17087 Prepared for: Bicycle Apartments, LLC c/o Next Step Housing P.O. Box 784 Yakima, WA 98907

ENGINEERING AND SURVEYING - Yakima, Washington · ENGINEERING AND SURVEYING ... Based on Table 20.3-1 found in ASCE-7, ... Coefficients of lateral pressure and unsaturated equivalent

  • Upload
    doanthu

  • View
    219

  • Download
    1

Embed Size (px)

Citation preview

Page 1: ENGINEERING AND SURVEYING - Yakima, Washington · ENGINEERING AND SURVEYING ... Based on Table 20.3-1 found in ASCE-7, ... Coefficients of lateral pressure and unsaturated equivalent

ENGINEERING AND SURVEYING

REPORT ON GEOTECHNICAL OBSERVATIONS

Bicycle Apartments, LLC

Proposed Residential Housing Development 118 North 50th Avenue

Yakima, Washington 98907

Yakima County Tax Parcel Id: 181321-41425

April 11, 2017

PLSA Project No. 17087

Prepared for:

Bicycle Apartments, LLC c/o Next Step Housing

P.O. Box 784

Yakima, WA 98907

Page 2: ENGINEERING AND SURVEYING - Yakima, Washington · ENGINEERING AND SURVEYING ... Based on Table 20.3-1 found in ASCE-7, ... Coefficients of lateral pressure and unsaturated equivalent

i

Table of Contents 1 Introduction ............................................................................................................................. 1

2 Land Use and Surface Conditions ........................................................................................... 1

3 Seismic Considerations............................................................................................................ 1

4 Liquifaction Potential .............................................................................................................. 2

5 Sub-Surface Conditions ........................................................................................................... 2

6 Soil Bearing Recommendations .............................................................................................. 3

7 Lateral Earth Pressure .............................................................................................................. 3

8 Structural Fill ........................................................................................................................... 4

9 Stormwater Disposal (Soil Infiltration Rates) ......................................................................... 4

10 Paving Recommendations .................................................................................................... 5

Page 3: ENGINEERING AND SURVEYING - Yakima, Washington · ENGINEERING AND SURVEYING ... Based on Table 20.3-1 found in ASCE-7, ... Coefficients of lateral pressure and unsaturated equivalent

1

1 INTRODUCTION

Bicycle Apartments, LLC, retained PLSA Engineering and Surveying to perform a geotechnical

investigation on an approximate 3 acre property, located approximately 1 block south of

Summitview Avenue, on the west side of 50th Avenue in Yakima Washington. See Appendix “A”

for vicinity map.

This report summarizes the results of our geotechnical investigation and offers our

recommendations for soil bearing values and site preparation for mobilizing soil support for a

future paved parking facility. The investigation consisted of visual inspection of the area, drawing

upon extensive local knowledge of nearby soil conditions, and examination and logging of 5 test

pits excavated using a John Deere 410L tractor mounted backhoe. See Appendix “B” Test Pit

Location Map. A geotechnical engineer from PLSA, experienced with local soil conditions, logged

the excavations and observed and field classified the soils found.

Included in this report are the following:

• Seismic zone information.

• Liquefaction Potential.

• Excavation logs and field classifications of the soils encountered in the 5 test pits.

• Estimated frost penetration.

• Structural fill recommendations.

• Recommended minimum footing depth and width.

• Recommended footing trench preparation.

• Soil bearing recommendations.

• Lateral Earth Pressure

• Stormwater Recommendations

• Slab on grade support recommendations.

• Parking lot site preparation and paving recommendations.

2 LAND USE AND SURFACE CONDITIONS

The subject property is vacant and located on a bench approximately 6 feet above 50th Avenue and

the adjacent property to the south. Elevations on the north and west boundaries are nearly level

with the adjacent properties along those boundaries. The site generally slopes to the South at

approximately 5 percent. The surface is well vegetated with healthy field grass. Several large trees

populate the northwest corner. Surrounding property use consists of a mix of residences and

commercial and professional businesses.

3 SEISMIC CONSIDERATIONS

Based on Table 20.3-1 found in ASCE-7, Chapter 20, and the firm silt observed during the field

investigation, the site is classified as Soil Class D. This classification is also in general agreement

with the Site Class Map of Yakima County, Washington published by the Washington State

Page 4: ENGINEERING AND SURVEYING - Yakima, Washington · ENGINEERING AND SURVEYING ... Based on Table 20.3-1 found in ASCE-7, ... Coefficients of lateral pressure and unsaturated equivalent

2

Department of Natural Resources. Site specific design values, using the Class D designation, are

provided below in Table 1.

Table 1: USGS Seismic Design Parameters

0.2 Second 1.0 Second

Maximum Considered Earthquake (MCE) Spectral

Acceleration

Ss=0.525 S1=0.215

Site Coefficient Fa=1.380 Fv=1.970

MCE Adjusted for Site Class effects SMS=0.724 SM1=0.424

Design Spectral Acceleration SDS=0.483 SD1=0.283

4 LIQUEFACTION POTENTIAL

Liquefaction is a phenomenon caused by a rapid increase in pore water pressure, in loose soils,

that reduces the effective stress between soil particles to near zero. This rapid increase in pore

water pressure can cause a loss of soil shear strength. Groundwater was not observed during the

field investigation and is known to be at depths of more than 50 feet below the ground surface

(bgs). Absence of groundwater eliminates the potential of liquefaction. In agreement with the field

observations, the Washington State Department of Natural Resources Liquefaction Susceptibility

maps show the susceptibility of this location to be low.

5 SUB-SURFACE CONDITIONS

Observations in all 5 test pits were similar. Fill consisting of 1 to 3 feet of sandy silt was observed

overlying a deep stratum of silt that increased in cemented qualities with depth. Hard pan can be

expected at a depth of 10 feet bgs. See test pit logs found in Appendix “C”.

USDA Soil Conservation Service classifies the native topsoil as "Esquatzel Silt Loam".

Permeability reported as moderately high, and therefore suitable for on-site stormwater disposal.

Before designing any on-site stormwater disposal system, an investigation of current local

stormwater disposal requirements is recommended.

Frost action is usually severe in the area due to the water holding capacity of the silt soil. Frost

penetration for the project location is estimated at 30 inches. Frost damage may be minimized by

placing footings a minimum of 30 inches below finished grade and by directing drainage away

from the buildings.

Page 5: ENGINEERING AND SURVEYING - Yakima, Washington · ENGINEERING AND SURVEYING ... Based on Table 20.3-1 found in ASCE-7, ... Coefficients of lateral pressure and unsaturated equivalent

3

6 SOIL BEARING RECOMMENDATIONS

PLSA understands that development of the property will include the construction of 5 apartment

buildings with up to 3 stories and 80 apartment units. The development will also include all

necessary utilities, access drives, parking lots, and pedestrian sidewalks. A minimum footing depth

of 3 feet below finished grade is recommended, for mobilization of soil strength and frost

protection. Footing depth is measure to the bottom of the gravel capillary barrier as specified

below. The recommended minimum footing width is two feet.

Recommended footing trench preparation is as follows: Excavated footing trenches two feet

wider than the footing width and 12 inches deeper than the desired bottom of concrete footing

depth. Proof roll the exposed trench bottom to 95 percent of maximum density as determined by

ASTM D-1557. Place a minimum of 12 inches of compacted, cohesionless, free-draining, gravel,

such as 1¼ inch minus crushed surfacing base course, in the prepared footing trench, up to desired

bottom of concrete footing grade. Compact the crushed rock in lifts to 95 percent of maximum

density as determined by ASTM D-1557 to produce a firm, stable, and unyielding surface. Using

a minimum footing width and the footing trench preparation recommended above, satisfactory soil

support for loadings up to 2,000 pounds per square foot (psf) should be achieved. If a greater soil

bearing value is required contact this office for additional recommendations.

Slabs on grade may be placed over silt surface soil. Remove all vegetation and other organic

material from over areas planned to support slabs. Compact the exposed surface, for depth of 8

inches, to 95 percent of maximum compaction as determined by ASTM D-1557. If optimum

moisture content for compaction is exceeded, dry the soil by excavation, aeration, or replacement.

Place a 6-inch minimum thickness, capillary barrier, consisting of compact, granular, free-draining

material such as 5/8 inch minus crushed rock meeting APWA standard specifications for top

course. Compact the granular material in a minimum of two layers to 95 percent of maximum

density as determined by ASTM D-1557. Using this preparation, a subgrade reaction value, Ks,

of 200 pounds per cubic inches (pic) should be achieved.

All roof and surface drainage is recommended to be directed away from the footings and exterior

slabs. Buildings should be elevated or placed on structural fill as necessary to provide slope to

insure adequate drainage.

7 LATERAL EARTH PRESSURE

Magnitude of lateral earth pressure varies with the height of the supported face, soil internal

friction, backfill soil density, presence or absence of water, and amount of surcharge, if any. PLSA

recommends selecting 110 pounds per cubic foot (pcf) as an appropriate unit weight of compacted

native soil backfill. Use of other soil types for backfill will require using a unit weight appropriate

for the type of soil selected.

Page 6: ENGINEERING AND SURVEYING - Yakima, Washington · ENGINEERING AND SURVEYING ... Based on Table 20.3-1 found in ASCE-7, ... Coefficients of lateral pressure and unsaturated equivalent

4

Coefficients of lateral pressure and unsaturated equivalent fluid weight for the native silt is as

follows:

Equivalent Fluid Wt. (pcf)

Sand & Gravel

Active Ka 0.33 40

At Rest Ko 0.50 55

Passive Kp 3.00 330

8 STRUCTURAL FILL

All areas to receive structural fill are recommended to be stripped of all paving, vegetation, organic

material, and trash. Proof rolled the exposed surface to 95 percent of maximum density as

determined by ASTM D-1557 for a depth of 6 inches before placing fill. The soil should be near

optimum moisture content for compaction. Add water or dry the soil by processing as necessary

to achieve moisture content suitable for compaction. If the fill subgrade soils are persistently too

wet to achieve specified compaction, contact this office for additional fill subgrade preparation

recommendations.

Imported soil used for structural fill is recommended to be cohesionless, free draining, non-plastic

material with a maximum particle size of two inches, or other material as approved by a

geotechnical engineer from this office.

All structural fill should be placed and compacted in layers not exceeding 6 inches in thickness.

Water should be added as needed to achieve satisfactory moisture content for compaction. Soils

too wet to be adequately compacted should be dried to a suitable moisture content before

incorporation into structural fill. Recommended compaction for structural fill is 95 percent of

maximum density as determined by ASTM D-1557. It is further recommended that all soil

compaction as recommended herein be monitored using a nuclear density gauge and documented.

Structural fill should not be placed over debris which may be poorly consolidated or contain

organic material or metal that may decompose and settle with time. All such unsuitable materials

should be removed and replaced with additional structural fill as described above.

Excavations resulting from removal of underground structures such as septic tanks, or petroleum

tanks are recommended to be backfilled using procedures described for structural fill.

Structural fill placed as described above is expected to provide bearing support equivalent to that

for recommended preparation of footing trenches in the native soil supporting the fill. Soil bearing

support for slabs on grade on structural fill placed as recommended herein is also expected to be

equivalent to that recommended for the native soil prepared as recommended herein.

9 STORMWATER DISPOSAL (SOIL INFILTRATION RATES)

The soil observed for several feet below the ground surface contains a fine silt and/or significant

silt component. The USDA Web Soil Survey reports that these soils are classified in the

Page 7: ENGINEERING AND SURVEYING - Yakima, Washington · ENGINEERING AND SURVEYING ... Based on Table 20.3-1 found in ASCE-7, ... Coefficients of lateral pressure and unsaturated equivalent

5

Hydrologic Soils Group B with a moderately high rate of infiltration. The minimum report cation-

exchange capacity (CEC), for the native soil, is 7.5 milliequivalents per 100 grams of dry soil,

exceeding the minimum requirement of 5 milliequivalents. The site is suitable for stormwater

disposal by infiltration. Based on experience with these soils, a long-term infiltration rate of 0.50

inches per hour can be expected for the native undisturbed silt. All construction traffic is

recommended to be prohibited in areas that are proposed to be used for stormwater infiltration.

Even minimal incidental compaction can reduce infiltration performance significantly.

All roof and surface drainage is recommended to be directed away from the footings. Buildings

should be elevated or placed on structural fill as necessary to provide slope to insure adequate

drainage.

10 PAVING RECOMMENDATION

All areas to be paved should be cleared of all grass, roots, trash, metal and organic materials down

to full depth below the paving mat. The exposed soil surface should then be proof rolled to a 6-

inch depth, to 90 percent of the maximum theoretical density as determined by ASTM D-1557,

using a mechanical vibratory compactor.

The following specification is our recommendation for paving and subgrade: Asphaltic Concrete

Paving, mix design and placement, shall conform to Washington State Department of

Transportation (WSDOT) Standard Specifications 2016, Division 5, Class HMA ½. Areas subject

to truck traffic shall be a minimum of 3 inches, compacted thickness, of asphaltic concrete placed

over a minimum of 9 inches of free-draining, crushed surfacing conforming to the particle size

distribution for Base Coarse found in section 9-03.9(3) of the WSDOT Standard Specifications.

Base Coarse gravel shall be compacted in lifts to 90 percent of the maximum theoretical density

as determined by ASTM D-1557, using a mechanical vibratory compactor.

Asphaltic concrete paving placed on parking lot areas used exclusively by automobiles may be

reduced to 2 inches compacted thickness.

Page 8: ENGINEERING AND SURVEYING - Yakima, Washington · ENGINEERING AND SURVEYING ... Based on Table 20.3-1 found in ASCE-7, ... Coefficients of lateral pressure and unsaturated equivalent

APPENDIX A:

Vicinity Map

Page 9: ENGINEERING AND SURVEYING - Yakima, Washington · ENGINEERING AND SURVEYING ... Based on Table 20.3-1 found in ASCE-7, ... Coefficients of lateral pressure and unsaturated equivalent
Garland
Image
GarlandS
Rectangle
GarlandS
Text Box
FIGURE 1 VICINITY MAP 118 North 50th Avenue, Yakima, WA PREPARED FOR Bicycle Apartments, LLC
GarlandS
Rectangle
GarlandS
Line
GarlandS
Line
GarlandS
Text Box
PLSA ENGINEERING-SURVEYING-PLANNING 521 NORTH 20TH AVENUE, YAKIMA, WA (509) 575-6990
GarlandS
Text Box
Date: 04-11-2017
GarlandS
Text Box
PLSA Project No. 17087
GarlandS
Text Box
Yakima County Parcel 181321-41425
GarlandS
Callout
SITE: 118 North 50th Avenue Yakima, WA
Page 10: ENGINEERING AND SURVEYING - Yakima, Washington · ENGINEERING AND SURVEYING ... Based on Table 20.3-1 found in ASCE-7, ... Coefficients of lateral pressure and unsaturated equivalent

APPENDIX B:

Test Pit Location Map

Page 11: ENGINEERING AND SURVEYING - Yakima, Washington · ENGINEERING AND SURVEYING ... Based on Table 20.3-1 found in ASCE-7, ... Coefficients of lateral pressure and unsaturated equivalent
Garland
Image
GarlandS
Rectangle
GarlandS
Ellipse
GarlandS
Polygon
GarlandS
Polygon
GarlandS
Line
GarlandS
Workpoint
GarlandS
Ellipse
GarlandS
Polygon
GarlandS
Polygon
GarlandS
Line
GarlandS
Workpoint
GarlandS
Ellipse
GarlandS
Polygon
GarlandS
Polygon
GarlandS
Line
GarlandS
Workpoint
GarlandS
Text Box
TP-1
GarlandS
Text Box
TP-2
GarlandS
Text Box
TP-3
GarlandS
Text Box
TEST PIT LOCATION MAP 118 NORTH 50TH AVENUE, YAKIMA WA PREPARED FOR BICYCLE APARTMENTS, LLC
GarlandS
Rectangle
GarlandS
Ellipse
GarlandS
Polygon
GarlandS
Polygon
GarlandS
Line
GarlandS
Workpoint
GarlandS
Text Box
TP-? Approximate Test Pit Location
GarlandS
Line
GarlandS
Line
GarlandS
Text Box
PLSA ENGINEERING-SURVEYING-PLANNING 521 North 20th AVENUE, YAKIMA, WA (509) 575-6990
GarlandS
Text Box
Date: 04-11-2017
GarlandS
Text Box
PLSA Project No. 17087
GarlandS
Text Box
Yakima County Parcel 181321-41425
GarlandS
Text Box
N
GarlandS
Ellipse
GarlandS
Polygon
GarlandS
Polygon
GarlandS
Line
GarlandS
Workpoint
GarlandS
Text Box
TP-4
GarlandS
Ellipse
GarlandS
Line
GarlandS
Line
GarlandS
Line
GarlandS
Rectangle
GarlandS
Rectangle
Garland
Ellipse
Garland
Polygon
Garland
Polygon
Garland
Line
Garland
Workpoint
Garland
Text Box
TP-5
Garland
Text Box
North 50th Avenue
Garland
Text Box
Summitview Avenue
Page 12: ENGINEERING AND SURVEYING - Yakima, Washington · ENGINEERING AND SURVEYING ... Based on Table 20.3-1 found in ASCE-7, ... Coefficients of lateral pressure and unsaturated equivalent

APPENDIX C:

Test Pit Logs

Page 13: ENGINEERING AND SURVEYING - Yakima, Washington · ENGINEERING AND SURVEYING ... Based on Table 20.3-1 found in ASCE-7, ... Coefficients of lateral pressure and unsaturated equivalent

PLSA ENGINEERING & SURVEYING

By: SDG Date: 3/6/2017

Elevation: N/A

Dep

th (

ft)

Mo

istu

re

Co

nte

nt

%

Un

it

Wei

gh

t

Sa

mp

le

UC

S

Sy

mb

ol

1 ML

2

3

4

5

ML

6

7

8

9

10

11

12

13

14

15

16

RemarksDescription

Surface Conditions: Grass

Location: NE 1/4 of Site

EXCAVATION LOG NO.: 1

509-575-6990

1120 WEST LINCOLN AVENUE

YAKIMA, WA 98902

Project No.: 17087

ML Silt

Sandy Silt

Thin Ash Layer

Silt

Firm - Fill

Med Brown

Moist

Firm

Dark Brown

Firm

Light Brown

Dry

Very Firm

DryML Partially Cemented Silt

Page 14: ENGINEERING AND SURVEYING - Yakima, Washington · ENGINEERING AND SURVEYING ... Based on Table 20.3-1 found in ASCE-7, ... Coefficients of lateral pressure and unsaturated equivalent

PLSA ENGINEERING & SURVEYING

By: SDG Date: 3/6/2017

Elevation: N/A

Dep

th (

ft)

Mo

istu

re

Co

nte

nt

%

Un

it

Wei

gh

t

Sa

mp

le

UC

S

Sy

mb

ol

1 ML

2

3

4

5

ML

6

7

8

9

10

11

12

13

14

15

16

ML Partially Cemented Silt Very Firm

Dry

Firm

Silt Light Brown

Dry

Firm - Fill

Sandy Silt Med Brown

Moist

Location: NW 1/4 of Site

Surface Conditions: Grass

Description Remarks

1120 WEST LINCOLN AVENUE

YAKIMA, WA 98902

509-575-6990

EXCAVATION LOG NO.: 2

Project No.: 17087

Page 15: ENGINEERING AND SURVEYING - Yakima, Washington · ENGINEERING AND SURVEYING ... Based on Table 20.3-1 found in ASCE-7, ... Coefficients of lateral pressure and unsaturated equivalent

PLSA ENGINEERING & SURVEYING

By: SDG Date: 3/6/2017

Elevation: N/A

Dep

th (

ft)

Mo

istu

re

Co

nte

nt

%

Un

it

Wei

gh

t

Sa

mp

le

UC

S

Sy

mb

ol

1

ML

2

3

4

5

ML

6

7

8

9

10

11

12

13

14

15

16

Firm

Cemented Silt Light Brown

Dry

Thin Ash Layer

Moist

Firm - Fill

Sandy Silt Med Brown

Location: SW 1/4 of Site

Surface Conditions: Grass

Description Remarks

1120 WEST LINCOLN AVENUE

YAKIMA, WA 98902

509-575-6990

EXCAVATION LOG NO.: 3

Project No.: 17087

Page 16: ENGINEERING AND SURVEYING - Yakima, Washington · ENGINEERING AND SURVEYING ... Based on Table 20.3-1 found in ASCE-7, ... Coefficients of lateral pressure and unsaturated equivalent

PLSA ENGINEERING & SURVEYING

By: SDG Date: 3/6/2017

Elevation: N/A

Dep

th (

ft)

Mo

istu

re

Co

nte

nt

%

Un

it

Wei

gh

t

Sa

mp

le

UC

S

Sy

mb

ol

1 ML

2

3

4

ML

5

6

7 ML

8

9

10

11

12

13

14

15

16

Cemented Silt Very Firm

Dry

Dry

Firm

Partially Cemented Silt Light Brown

Firm - Fill

Sandy Silt Med Brown

Moist

Location: South Center Area of Site

Surface Conditions: Grass

Description Remarks

1120 WEST LINCOLN AVENUE

YAKIMA, WA 98902

509-575-6990

EXCAVATION LOG NO.: 4

Project No.: 17087

Page 17: ENGINEERING AND SURVEYING - Yakima, Washington · ENGINEERING AND SURVEYING ... Based on Table 20.3-1 found in ASCE-7, ... Coefficients of lateral pressure and unsaturated equivalent

PLSA ENGINEERING & SURVEYING

By: SDG Date: 3/6/2017

Elevation: N/A

Dep

th (

ft)

Mo

istu

re

Co

nte

nt

%

Un

it

Wei

gh

t

Sa

mp

le

UC

S

Sy

mb

ol

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ML Cemented Silt

ML Silt

ML Sandy Silt

Very Firm

Light Brown

Dry

Firm

Med Brown-Moist

Firm - Fill

Med Brown-Moist

Thin Ash Layer

Location: East 1/3 of Site

Surface Conditions: Grass

Description Remarks

1120 WEST LINCOLN AVENUE

YAKIMA, WA 98902

509-575-6990

EXCAVATION LOG NO.: 5

Project No.: 17087